m i c r o a n a l y s i s

NORAN System 7

Spectral Imaging X-ray Microanalysis System

Spectral Analysis

Point & Shoot

Spectral Imaging

COMPASS: Component Analysis of Spectral Images

Part of Thermo Fisher Scientific


X-ray Microanalysis
NORAN System 7 High Throughput, Impeccable Accuracy and No Compromises
The Thermo Scientific NORAN System 7 provides the ultimate in micro-
analysis capabilities for the modern electron microscopy lab: X-ray detectors
with the highest sensitivity, pulse processors and digital imaging with the
highest throughput and the most sophisticated software suite available.
Combined together, NORAN System 7 produces accurate results and
answers in seconds making your lab a better place to work.

• Automatic Peak Identification • Accurate Peak Intensities


Using rule-based identification and peak Elemental peak references provide a
shape deconvolution, elemental peaks complete set of spectral peak shapes
are automatically identified quickly and collected with a typical EDS system. The
accurately. intensities from these shapes are auto-
matically corrected to match the detector
• Confirm Elements Present
on your microscope, eliminating the need
SpectraCheck both visually and statistically
to periodically calibrate the system with
confirms the presence of an element using
standards.
spectrum simulation and comparison
routines to provide both an overlapped • Precise Matrix Correction
spectrum, and a chi-squared value Since 1983 Thermo Scientific X-ray
indicating goodness of fit. analyzers have been using the PROZA
Phi-Rho-Z matrix correction algorithm as
implemented by Bastin et al. This model
of Phi-Rho-Z has been shown to have
superior performance to all other methods
of matrix correction.

Digital Pulse Processing: Compress Your Data Acquisition Time


The NORAN System 7 redefines X-ray pulse detectors, NORAN System 7 speeds the path
processing. Capable of processing more to answers by reducing the amount of time
than 1,000,000 counts per second, the necessary to collect data. In addition,
NORAN System 7 more than doubles processing algorithms and electronics
previously available count rates. pioneered by Thermo Scientific in 1992 and
Whether you use Si(Li) or SDD continually developed since then to produce
spectrum with no peak shift or peak broad-
ening, from minimum to maximum count rates.

NORAN System 7
Analyzer
UltraDry
X-ray Detector

Application
Software
Getting to the answer quickly and accurately is critical in today’s
microscopy laboratory. Often you must answer the question of
“What is the composition at one or more areas of the sample?”

Point & Shoot


Point & Shoot mode integrates electron
imaging and X-ray analysis. A single mouse
click provides both elemental identification
and quantitative analysis of the selected
areas of interest of the sample.
Areas on the sample are defined using
points, rectangles, circles, polygon or with a
magic wand tool. The magic wand tool
allows you to easily and instantly outline
complex areas without having to manually Multiple spectral processing and analysis steps are performed automatically
draw a border. The selection, based on gray as part of the acquisition
levels, is made automatically with just one
click. The selected areas may be analyzed
instantly or multiple areas may be selected
for automated analysis. Point & Shoot per-
forms processing according to your settings.
With Point & Shoot everything you need is
in one place. From qualitative to quantita-
tive analysis with full standards, Point &
Shoot is the easiest place to get the spec-
tral results you need.

Point & Shoot image overlaid with a user-drawn polygon shape and an
automatic magic wand shape

Your Results

Comparison report of spectra collected from different


shapes on a single Point & Shoot image
X-ray Microanalysis
NORAN System 7 Spectral Imaging X-ray Microanalysis
Spectral Imaging has revolutionized x-ray mapping. With a spectrum
acquired at every point it is the centerpiece for all imaging, X-ray mapping,
Linescan and advanced automated analysis. With one click, the NORAN
System 7 collects data that can be analyzed repeatedly without the need
for re-acquiring or changing acquisition parameters. Once the data is
collected, you may choose to analyze it locally at the microscope or take
the data offline to a different computer for report preparation.

Spectral Imaging provides for the display of


any number of element maps, both during
and after the acquisition. It includes a rich
set of data extraction and analysis functions
Spectral Imaging Data Extraction Tools:
for interpreting the data.
• Rectangle
Many methods exist to select spectra
• Magic Wand, a unique tool that allows
for analysis from a Spectral Imaging dataset –
the selection of areas by gray levels
in fact the only limit is your imagination.
• Circle
Because every spectrum from the dataset
• Polygon, for freehand drawn areas
is fully deadtime corrected during the
• Linescans, with variable number of points
acquisition, each spectrum can be used for and width
standardless or full standards quantitative
analysis. A single button selection changes
the display from a summed spectrum to a
maximal spectrum.

The spectral imaging data


cube contains an electron
image and a spectrum
at every point.

Network-Ready Data Analysis


From its inception, the NORAN System 7 was designed for the
easy transfer of information over a data network. This allows
the microscopist to analyze data away from the lab.
Projects are stored as folders in Windows® Explorer®,
which groups the analyses of samples or sample sets for easy
retrieval. NORAN System 7 software can be installed on multiple
computers using the site license included with every system.
Projects can then be conveniently accessed and analyzed from
your office or any other compatible computer within the facility.
Data can also be situated on a Windows Server System™
allowing for backup and support by your local IT group.
Automatic Quantitative Mapping –
Confidence in Your Results
Difficult to interpret sample compositions can now The example shown here displays gross count
be identified effortlessly with the Noran System 7 and weight % maps. When basic X-ray mapping is
exclusive automatic quantitative mapping. Going used, the gross count maps all appear the same
far beyond simple X-ray maps, Noran System 7 due to peak overlaps between Si, Ta and W. It is
sets a new standard in sample analysis. With just only with the application of full quantitative analysis
one click difficult-to-interpret X-ray maps are that the spatial separation becomes evident. Had
transformed into clear elemental maps without only basic X-ray mapping been used, an accurate
peak overlaps or background effects. This full interpretation of the composition could not be
quantitative analysis is done effortlessly, yet uses determined.
the power of least squares fitting to provide
results you will have confidence in every time.

Only the NORAN System 7 produces full quantitative analysis


from every point in your sample

Gross Count Maps

Without full quantitative analysis, the gross count


maps all appear the same due to peak overlap issues

Weight % Maps

With the application of full quantitative analysis the


spatial separation becomes evident
X-ray Microanalysis
NORAN System 7 COMPASS Multivariate Statistical Analysis Software
Traditional X-ray microanalysis systems National Labs, COMPASS allows, with a
allow each microscopist to choose the single click of a button, the automatic and
elements for analysis. This can lead to complete analysis of a Spectral Imaging
different results form the same sample, dataset.
depending on who performed the analysis. The results from COMPASS consist of a
Have you ever wondered how you could get set of spectrum and component images
all of the people in the lab to perform the showing the spatial distribution of the
same analysis and obtain the consistent component within the sample. COMPASS is
results? COMPASS software is the answer. the ideal tool for anyone wishing to auto-
This additional software tool for use with matically analyze spectral images or X-ray
NORAN System 7 uses powerful multivariate maps. Since COMPASS algorithms are
statistical algorithms as created by Paul largely free of user input, everyone gets the
Kotula et al. and licensed from Sandia same answer, the CORRECT answer.

1-Click Reporting
in all Modes
Just One Click to:
• Print report
• Open in Microsoft® Office Word
• Open in Microsoft Office PowerPoint®
Xphase Compositional Distribution Mapping Software
While analysis using COMPASS is the
ultimate in automatic, hands-free Spectral
Imaging analysis, our Xphase software
gives you the option to take full control of
the results.
Xphase software uses any set of
images of the sample – whether they are
raw maps, quantitative maps or COMPASS
distribution images – and calculates which
areas of the sample have nearly the same
composition. It then creates a binary image
for the each area. Spectra representing
each of the resultant phases is extracted
from the Spectral Imaging data cube by
using the binary images as a mask. The
result is that with little effort you determine
which areas of the sample have the same
composition, and then generate images and
spectra representing those areas.

A concise report shows where a phase or compound is located and the


associated spectra

Automatic Acquisition Management


In traditional X-ray microanalysis systems, managing the optimal acquisition condition is a
trial-and-error process. The NORAN System 7 monitors the acquisition and fine tunes the
system during operation to ensure that the best data is collected every time an acquisition is
started. Guesswork and rework are eliminated.

• Pulse Processor Rate – Dynamically • High keV Cutoff – NORAN System 7 • Brightness/Contrast – There is no need
adjusts the analyzer to the conditions only acquires the data that is necessary to fine tune the image brightness and
of the microscope. Simply adjust the economizing on storage space and contrast – NORAN System 7 does it
microscope for the optimum image and processing speed. for you.
NORAN System 7 adjusts accordingly.
• Acquisition Time – Acquisition times • Drift Compensation Time – Optimizes
• Peak Suppression – The Zero Peak is a based on statistics, rather than fixed the time between compensation cycles
useful diagnostic tool. When it is not time, ensure that the data collected is improving data throughput.
needed, NORAN System 7 removes it significant.
from view so you can concentrate on the
elemental data.

Dual Detector Operation


The NORAN System 7 allows up to two detectors to be attached to a single analyzer
system. Data can be collected in any acquisition mode selecting a single detector or
by selecting both detectors. Dual detector operation gives you more the 2,000,000
counts per second processing capability. Configurations may include deployment of
two Si(Li) detectors, two SDD units, or one Si(Li) and one SDD combination.
In addition to these offices, Thermo
Fisher Scientific maintains a network
NORAN System 7 Options of representative organizations
throughout the world.

NORAN System 7 provides the ultimate in power, flexibility and ease –


Australia
even when analyzing complex samples. Included with the powerful digital +61 2 8844 9500 • analyze.au@thermo.com
pulse processing and digital imaging hardware is a suite of software Austria
+43 1 333 50340 • analyze.at@thermo.com
unparalleled in the industry. Revolutionary software tools enable users to
Belgium
eliminate tedious manual data extraction steps and multiple software +32 2 482 30 30 • analyze.be@thermo.com
licenses allow users to access and analyze data from computers outside the Canada
+1 800 532 4752 • analyze.ca@thermo.com
lab. With state-of-the-art algorithms for spectral and spectral image analysis China
you can quickly generate the information you need and have confidence in +86 10 5850 3588 • analyze.cn@thermo.com
Denmark
the results generated by NORAN System 7. The following options can +45 70 23 62 60 • analyze.dk@thermo.com
further enhance the productivity of your NORAN System 7 EDS System. France
+33 1 60 92 48 00 • analyze.fr@thermo.com
Germany
COMPASS Direct-To-Phase +49 6103 408 1014 • analyze.de@thermo.com
Automatically analyze Spectral Imaging Combines the functions of COMPASS, India
datasets resulting in component images and Xphase and Match to automatically analyze +91 22 6742 9434 • analyze.in@thermo.com
Italy
spectra. The fastest method for all users to Spectral Imaging data sets during the
+39 02 950 591 • analyze.it@thermo.com
obtain the correct result from the analysis. acquisition. In one step the entire acquisition Japan
and analysis is completed providing +81 45 453 9100 • analyze.jp@thermo.com
Xphase
compound/phase images and spectra. Latin America
Provides full control of the process for +1 608 276 5659 • analyze.la@thermo.com
When the final result is achieved, no further
determining compounds and phases within Netherlands
processing is needed. Simply click the the
a sample. Allows the usage of X-ray maps, +31 76 587 98 88 • analyze.nl@thermo.com
report button. South Africa
quantitative maps, COMPASS and electron
+27 11 570 1840 • analyze.sa@thermo.com
images to determine areas that define areas Drift Compensation
Spain
of similar composition. Automatically compensate for image or +34 91 657 4930 • analyze.es@thermo.com
stage drift. Allows for extended acquisitions Sweden / Norway / Finland
Column Communication +46 8 556 468 00 • analyze.se@thermo.com
on all SEMs or STEM.
Communicates with the electron microscope Switzerland
via serial or Ethernet connections to auto- Feature Sizing +41 61 48784 00 • analyze.ch@thermo.com
matically retrieve the magnification, kV and Particle/inclusion analysis and chemical UK
+44 1442 233555 • analyze.uk@thermo.com
working distance each time data is acquired identification determines the morphology
USA
from the sample. and composition of identifiable features in +1 800 532 4752 • analyze.us@thermo.com
a sample. Combined with the Automation
Automation www.thermo.com
tool, the Feature Sizing tool can be used
Sample analysis at multiple areas using
to perform unattended particle/inclusion
stage automation. Up to 6 axis can be
analysis.
automated. Each mode of NORAN System 7
uses the same automation interface making Portal
repetitive analysis direct and simple. Integration with third party applications
such as Gatan DigitalMicrograph™, Probe
Match
For Windows or FEI EMISPEC ESV.
Uniquely identifies a spectrum by comparing
its shape to that of other spectra in a
database. Match is provided with an alloy Thermo Electron Scientific Instruments LLC,
Madison, WI USA is ISO Certified.
database of more than 300 compounds.
©2007 Thermo Fisher Scientific Inc. All rights reserved.
Add your own additional Match standards DigitalMicrograph is a trademark of Gatan, Inc.
using measured spectra or numeric Microsoft, PowerPoint, Windows and Explorer are
registered trademarks of Microsoft Corp. Windows
quantitative values. Server System is a trademark of Microsoft Corp. All
other trademarks are the property of Thermo Fisher
Scientific Inc. and its subsidiaries.
Specifications, terms and pricing are subject to change.
Not all products are available in all countries. Please
consult your local sales representative for details.