00 ©2002 IEEE 113


0-7803-7185-2/02/$10.00 ©2002 IEEE 114
Pump chamber Flow channel pressure sensor
Drain port ruler
Outlet
Inlet
20 mm
Reservoir

Supply port
35 mm

(a) Flow Rate (b) Pressure


(a) micro pump chip
Measurement Measurement
Outlet Figure 7. Schematic of experimental setups.
3 mm
rate and pressure of the micro pump, respectively. The driving
(c) inlet waveforms were supplied to the electrical probes on PZT plate
by a function generator in combination with an amplifier. The
displacement of the PZT plate surface was directly measured by
Pump chamber
0.5 mm a Laser Doppler Vibrometer (LDV) to estimate the displacement
Inlet of the diaphragm on the pump chamber. The flow rate was
(b) pump chamber (d)outlet measured from the averaged speed of liquid level under almost
the same static pressure at the inlet and the outlet. The
Figure 6. Photograph of the completed micro
generated pressure at the outlet (forward direction) was
pump and SEM images of the pump chamber, the
measured by setting a pressure sensor at the end of the tube
inlet and the outlet channel.
connected to the drain port. The pressure was measured at
chamber, two diffusers and flow channels was formed by Deep zero flow rate with keeping the inlet open and the outlet closed.
Reactive Ion Etching (DRIE) process, as shown in Fig. 5 (4)-(6). The pump was turned on after the pressure reaching the
The remaining thickness of the silicon for the pump chamber equilibrium state. The generated pressure at inlet (backward
was available as a diaphragm. After removing the silicon direction) was measured in the same way as forward direction
dioxide layers, a indium tin oxide (ITO) layer was formed on the by setting the pressure sensor on the supply port side.
opposite surface of the silicon substrate. A pyrex glass plate
with supply and drain ports was stacked on the silicon by anodic RESULTS AND DISCUSSIONS
bonding. A 70 µm thick PZT plate was mounted on the
diaphragm with glue, as shown in Fig. 5 (7)-(8). Figure 8 shows the displacement of the diaphragm at
Figure 6 shows a photograph of the completed micro pump different voltage of 1 kHz sine wave. The theoretical values
with size of 20 mm x 35 m m x 0.7 mm and SEM images of the analyzed by FEM were compared with the experimental results.
pump chamber with size of 0.5 mm x 3 mm and the inlet/outlet The experimental values were about 70 % less than the
channels. theoretical ones. This discrepancy was thought to be caused by
inadequate poling of PZT, location error of PZT, thickness error
EXPERIMENTS of diaphragm and effect of glue layer.
Figure 9 and Figure 10 show the flow rate and the
The displacement of the diaphragm, flow rate and pressure generated pressure of the micro pump as a function of driving
were evaluated for the characteristics of the completed micro voltage (height of waveform) at 11 kHz of repeating frequency,
pump. The micro pump was set in a polycarbonate flame with respectively. The theoretical values were shown in the same
electrical probes and fluid connectors for measurement of flow graph. Bi-directional pumping was successfully confirmed.
rate and pressure. As a fluid connector, silicone tubes of 2 mm The pumping direction was switched over by changing the
inner diameter were used. shape of waveform and the flow rate was adjusted with good
Figure 7 (a) and (b) show the experimental setups of flow controllability in a range from 15 nl/s to 220 nl/s by changing the