Академический Документы
Профессиональный Документы
Культура Документы
Pressure Transmitters
DPharp EJA Series Differential Pressure DPharp EJX Series Differential Pressure
and Pressure Transmitters and Pressure Transmitters
Liq Liq
Gas Gas
Stm Stm
A field proven, best-selling pressure transmitter series Ultra-high performance, the newest model of DPharp.
featuring silicon resonant sensor. • Fast response.
• Proven track record throughout the world.
• High accuracy. Unique features include;
• Excellent long term stability slashes maintenance costs. • Multi-sensing (Differential pressure and Static pressure).
• Output signal characterizer.
Easy-to-use compact design. • Multi-functional indicator (optional).
• Alarm output for measured pressure and static pressure
Wide variety of product lineup. (optional).
Converts a temperature sensor or mV DC signal to a 4 to 20 mA Superb reliability and proven track record.
signal and transmits it.
Fully compliant with IEC (and JIS).
Minimizes the error due to the extension wires, thus improving the
accuracy. Variety of mounting hardware for application to
Only a small length of extension wires or three-core cable is required, all types of process.
thus reducing the wiring costs.
E Bulletin 00A03B02-01E The sensor type and measurement range can be set according to
b] the purpose.
Dual-compartment housing (YTA110, YTA310, and YTA320 )
SIL2 certified by TÜV NORD (YTA110, YTA310, and YTA320 with
BRAIN and HART protocol)
Field Instruments
Pressure Transmitters
DPharp EJA Series Differential Pressure DPharp EJX Series Differential Pressure
and Pressure Transmitters and Pressure Transmitters
Liq Liq
Gas Gas
Stm Stm
A field proven, best-selling pressure transmitter series Ultra-high performance, the newest model of DPharp.
featuring silicon resonant sensor. • Fast response.
• Proven track record throughout the world.
• High accuracy. Unique features include;
• Excellent long term stability slashes maintenance costs. • Multi-sensing (Differential pressure and Static pressure).
• Output signal characterizer.
Easy-to-use compact design. • Multi-functional indicator (optional).
• Alarm output for measured pressure and static pressure
Wide variety of product lineup. (optional).
Converts a temperature sensor or mV DC signal to a 4 to 20 mA Superb reliability and proven track record.
signal and transmits it.
Fully compliant with IEC (and JIS).
Minimizes the error due to the extension wires, thus improving the
accuracy. Variety of mounting hardware for application to
Only a small length of extension wires or three-core cable is required, all types of process.
thus reducing the wiring costs.
E Bulletin 00A03B02-01E The sensor type and measurement range can be set according to
b] the purpose.
Dual-compartment housing (YTA110, YTA310, and YTA320 )
SIL2 certified by TÜV NORD (YTA110, YTA310, and YTA320 with
BRAIN and HART protocol)
Field Instruments
Flowmeters Level Transmitters
ADMAG CA Capacitance EJA118W/EJX118A Differential
ADMAG AXF Magnetic Flowmeter Magnetic Flowmeter EJA210A/EJX210A Pressure Transmitters
Level Transmitter with Diaphragm Seals
Liq Liq
Liq Liq
Predictive diagnostics User-oriented functionality High performance Measures the flows of ultra-low
- lowers TCO - the global leader in stability conductivity fluids up to 0.01 µS/cm.
Multi-line backlit LCD. Non-wetted electrode structure ensures
Electrode adhesion detection reduces Enhanced dual frequency excitation. stable measurement free from the effects
process downtime. Easy-to-install rotatable primary
of build-up of insulating material or coating,
(converter). 0.2% reading accuracy (Optional). Flange-mounting, compact differential Ideal for measuring the levels and
and noise of high-density slurry fluid.
Replaceable electrode construction is pressure transmitter. densities of corrosive and high-
available. Multiple status alarms. 1 micro-S/cm conductivity. Maintenance costs greatly reduced. temperature fluids.
Direct mounting to a tank.
Error messages and diagnostic instructions Wide range of liners and electrode Maximum-speed response. Small flange size model also available.
simplify and optimize maintenance. materials.
Small flange size model also available.
Spectral signal processing automatically Built-in temperature sensor within the Combined with an orifice, measures Fully compensated mass flow: all flow
optimizes the settings at all times, from shedder bar offers the mass flow output or liquid, gas, and steam flow rates. factors can be automatically and
immediately after power-on. the temperature output. dynamically calculated to an optimal value.
Available for direct mounting without
Self-diagnostics, one step ahead of other No installation of the temperature device is three-valve manifold. 1.0% mass flow rate accuracy over 1:10
flowmeters, enables predictive needed for the process. Applicable to various actuators from Fieldbus-enabled digital valve positioner.
Outstanding long-term stability slashes flow range.
maintenance. diaphragms to cylindrical actuators, and
Durable meter design mostly meets the maintenance costs. Simultaneous dual output of 4 to 20 mA globe and rotary valves. A wealth of functions such as auto-tuning
Simultaneous analog and pulse signal steam flow such as water hammer, high to effectively use the combined valve.
and pulse signals for total flow, flow rate, Positions small and large valves (stroke:
outputs. temperature process, etc. or alarm status. 10 to 100 mm).
High-temperature and cryogenic models Reduced bore type measures lower Air consumption reduced to one quarter
also available. flowrate. that of previous models, reducing the cost
of generating instrument air.
US300FM Ultrasonic US300PM Portable ROTAMETER ROTAMASS
Flowmeter Ultrasonic Flowmeter Variable Area Flowmeter Coriolis Mass Flowmeter PK200 Current-to-Pneumatic
FieldMate Converter
Versatile Device Management Wizard BT200 BRAIN Terminal
Liq Liq Liq
Gas
Stm
Maximum two flow-input channels enable two path measurement Complete stainless steel Mass flow for nearly all flowing
or the measurement of two different flows in different pipes. design. fluids. High-performance, high-reliability electro-
The pipe sizes from 25 mm to 6,500 mm (1 to 255 inches). feedback achieves linearity of ±0.2%.
Local indication and analog Highly independent from As one integrated tool, FieldMate handles Hand-held terminal to communicate with
With the noise suppression technique, the measurement against parameter setting for intelligent field BRAIN communication-enabled instruments
output. external loads or vibrations Energy-efficient, cost-effective design.
air bubbles in the fluid has been vastly improved. devices regardless of field communication and devices for setting up, viewing,
through special decoupling
With the original signal processing, fast and accurate protocols. modifying, and printing parameters required Air consumption reduced to one quarter
Various process connections system.
measurement has been realized. for the instruments and devices to operate. that of previous models, reducing the
and wetted materials.
Precise flow and density FieldMate enables quicker device cost of generating instrument air.
The transducers are calibrated one by one when shipped and easy
Options such as Exi-version, measurement. configuration and problem solving, Special instrumentation work and parts
to install at the sites. It is not necessary to adjust zero flow
inductive alarms, pulse output, reducing complex and time-consuming not needed to replace the former electric-
condition, which has been often said to be necessary.
etc. Wide temperature range work steps. pneumatic converter, 5502.
US300PM portable type is equipped with wall thickness ( 200˚C to 350˚C).
measurement function. Note: Liq , Gas , and Stm symbols indicate applicable process fluid types (liquid, gas, steam).
Liquid Analyzers
pH/ORP Analyzers Conductivity Analyzers
PH450G PH202 PH100/OR100 PH71/PH72 pH/ORP Sensors SC450G DC402G SC202 SC100 ISC450G ISC202 SC72
for Conductivity
4-Wire pH/ORP 2-Wire pH/ORP Panel Mount pH/ORP Personal pH, 4-Wire Conductivity/ Dual Cell Conductivity/ 2-Wire Conductivity Panel Mount 4-Wire Inductive 2-Wire Inductive Personal
Process Use Sensors
Converter Transmitter Converters pH/ORP Meters Resistivity Converter Resistivity Converter Transmitter Conductivity Converter Conductivity Converter Conductivity Transmitter Conductivity Meter
PH8EFP/ SC4AJ-AD-09
PH8ERP
SC4AJ-AD-15
FU20
SC4AJ-SA
PH10
Large, high-resolution Designed for 2-wire Compact housing Waterproof (IP67) (for PH100) Large, high-resolution Differential, ratio or Designed for 2-wire Compact housing Large, high-resolution Designed for 2-wire Intelligent, portable
graphical display and configuration, construction allows graphical display and calculated outputs configuration, graphical display and configuration, SC4AJ-SB conductivity meter
Large, 4-digit digital Large, 4-digit digital
touchscreen allowing use in display measurement in wet touchscreen Universal conductivity allowing use in display touchscreen allowing use in large- with waterproof (IP67)
operation large-scale environment operation for ease of /resistivity, software large-scale operation for ease of scale instrumentation construction
Drip-proof (IP65) OR10 Drip-proof (IP65)
for ease of use instrumentation Various convenient (for OR100) use switchable instrumentation use A single stain- Various convenient
front panel (option) front panel (option) SC210G
Diagnostic functions Intrinsic safety: functions: 300-point Diagnostic functions Matrix temperature Intrinsic safety: ATEX, Diagnostic functions resistant sensor functions: 300-point
for minimum ATEX, CSA, FM, data memory, alarm for minimum compensation for CSA, FM, TIIS for minimum covers a wide data memory, alarm
maintenance TIIS clock, etc. maintenance pure water applications maintenance measuring range SC10XB (for SC100) clock, etc.
Temperature HA405/HA406 * Temperature * Temperature Intrinsic safety: ATEX,
Easy to use EXA
compensation and compensation, control panel compensation and CSA, FM, TIIS
predefined pH buffer predefined OIML predefined OIML Appropriate sensor
tables for best buffer tables, cell USP<645> monitoring buffer tables for best for your application
accuracy Appropriate sensor fouling monitoring accuracy.
for your application for best accuracy
Non-reagent Type Non-reagent Type Long-term stable sensor Universal input accepts
Polarographic method using Polarographic method using rotating Display unit in mg/l, ppm, or % Galvanic and Polarographic sensors
User configurable measuring range NTU turbidity unit display is Surface scattered light method using rotating gold electrode gold electrode Reagent Type saturation and various temperature
from 0-0.2 NTU to 0-100 NTU. available by Right-angled scattering kaolin, formazin, or PSL compensating elements
Ideal for measurement of free Ideal for measurement of free Polarographic method using rotating Temperature compensation,
Highly reliable measurement with light. (polystyrene latex) for calibration Wide measuring range including ppb,
available chlorine in water available chlorine in water supply platinum electrode salt concentration compensation and
excellent linearity and repeatability. Measuring Range: 0-0.1 to 0-100 Highly reliable measurement at water supply and distribution systems and distribution systems barometric air pressure ppm and % saturation
Ideal for measurement of residual
In-line connection available NTU/0-10 to 0-2000 NTU supply and sewage systems compensation for best accuracy Certification for hazardous area
Field-configurable from 0-1 to 0-3 Measuring range selectable: chlorine in chlorination processes of
Measuring range: 0-2 to 0-2000 mg/l mg/l for two switchable output 0-1/0-2/0-3 mg/l switchable or water supply systems and in cooling Ideal for measurement of dissolved (ATEX, IECEx, FM, CSA)
Easy-to-clean cell
(or degrees, unit selectable) ranges 0-5/0-10 mg/l switchable water of thermal power stations oxygen in aeration tanks at sewage Communication: mA HART,
Micro processor-based, intelligent Measuring range: 0 to 10mg/l treatment plants, etc. PROFIBUS-PA,
converter Foundation Fieldbus
MLSS Analyzer Liquid Density Meter FT-Near Infrared Analyzers Clean Room Gas Monitor
SS400G DM8 InfraSpec NR800 CM500
MLSS Analyzer Vibration Type Liquid Density Meter Fourier Transform Near Infrared Analyzers Clean Room Gas Monitor
Wide measuring range from 0-1000 mg/l to Measures liquid density with Continuous, multiple, Barcode reader Ideal for measurement of ammonia and
0-20000 mg/l high sensitivity and stability and simultaneous provides easy operation acid gases in clean rooms
Ideal for measurement of mixed liquor Measuring range of 0.5 to measurement of for at-line and routine
Highly reliable ion chromatograph
suspended solids (MLSS) in an aeration 2.0 g/cm3 unaffected by flow component concentration At-line Model analyses
and property values High sensitivity of 0.01µg/m3 for
tank of activated sludge processes in rate and viscosity Reduces operating
(density, polymerization ammonia and of 0.02 µg/m3 for acid
sewage and industrial wastewater treatment Detector is available in and maintenance costs
degree, octane value, gases
facilities general-purpose, sanitary, by consolidation of lab
etc.) of various processes and process calibration
and flameproof types On-line Model Measurement of trace models and on-site
water content available hands-on training
Gas Analyzers
Gas Chromatograph Oxygen Analyzers
GC1000 Mark II ZR402/ZR202 AV550G
Process Gas Chromatograph Direct In Situ Zirconia Averaging Converter
Oxygen Analyzers
ZR402G
ZR22G/S
Measures gas density with high sensitivity and quick Ideally suited for measuring Automatic range setup and no
response. Also capable of displaying specific gravity calorific values of gases in manual adjustment required
YOKOGAWA ELECTRIC CORPORATION Middle East India
and molecular weight derived from the density data. applications including city gas Triboelectric detection method YOKOGAWA MIDDLE EAST B.S.C.(C) YOKOGAWA INDIA LTD.
World Headquarters
Can be used in hazardous areas with explosive and iron & steel gas unaffected by dust adhesion 9-32 Nakacho 2-chome, Musashino-shi, http://www.yokogawa.com/bh/ http://www.yokogawa.com/in/
atmospheres (FM, CSA, TIIS) Tokyo 180-8750, JAPAN Singapore Australia
For bag filter detection and Tel: +81-422-52-6316 Fax: +81-422-52-6619 YOKOGAWA ENGINEERING ASIA PTE.LTD. YOKOGAWA AUSTRALIA PTY. LTD.
Hydrogen purity and replacement meter for power adjustment of electrostatic North America http://www.yokogawa.com/sg/ http://www.yokogawa.com/au/
generators precipitator efficiency YOKOGAWA CORPORATION OF AMERICA Korea
Georgia, U.S.A YOKOGAWA ELECTRIC KOREA CO., LTD.
http://www.yokogawa.com/us/ http://www.yokogawa.com/kr/
Infrared Gas Analyzers South America
YOKOGAWA AMERICA DO SUL LTDA.
China
YOKOGAWA CHINA CO., LTD.
BRAZIL http://www.yokogawa.com/cn/ Represented by:
http://www.yokogawa.com.br/ YOKOGAWA SHANGHAI INSTRUMENTATION CO., LTD.
IR100/IR200/IR400 NDIR Type Infrared Gas Analyzers SG700 Stack Gas Analyzer Europe http://www.ysi.com.cn/
YOKOGAWA EUROPE B.V. YOKOGAWA SICHUAN INSTRUMENT CO., LTD.
European Headquarters http://www.cys.com.cn/
Simultaneously THE NETHERLANDS Taiwan
measures NOX, SO2, http://www.yokogawa.com/eu/ YOKOGAWA TAIWAN CORPORATION
YOKOGAWA ELECTRIC CIS LTD. http://www.yokogawa.com.tw/
CO,CO2 and O2 with RUSSIAN FEDERATION
sampling system Vig-PMK-G·NL-07E
http://www.yokogawa.ru/
Printed in Japan, 805(KP) [Ed : 06/b]
IR100 IR200 IR400
Measuring Components
IR100: CO2, CO, CH4 IR200: CO2, CO, CH4, IR400: NO, SO2, CO2, CO, Subject to change without notice.
SO2, NO, O2 CH4, O2 All Rights Reserved, Copyright© 2001, Yokogawa Electric Corporation.
Gas Analyzers
Gas Chromatograph Oxygen Analyzers
GC1000 Mark II ZR402/ZR202 AV550G
Process Gas Chromatograph Direct In Situ Zirconia Averaging Converter
Oxygen Analyzers
ZR402G
ZR22G/S
Measures gas density with high sensitivity and quick Ideally suited for measuring Automatic range setup and no
response. Also capable of displaying specific gravity calorific values of gases in manual adjustment required
YOKOGAWA ELECTRIC CORPORATION Middle East India
and molecular weight derived from the density data. applications including city gas Triboelectric detection method YOKOGAWA MIDDLE EAST B.S.C.(C) YOKOGAWA INDIA LTD.
World Headquarters
Can be used in hazardous areas with explosive and iron & steel gas unaffected by dust adhesion 9-32 Nakacho 2-chome, Musashino-shi, http://www.yokogawa.com/bh/ http://www.yokogawa.com/in/
atmospheres (FM, CSA, TIIS) Tokyo 180-8750, JAPAN Singapore Australia
For bag filter detection and Tel: +81-422-52-6316 Fax: +81-422-52-6619 YOKOGAWA ENGINEERING ASIA PTE.LTD. YOKOGAWA AUSTRALIA PTY. LTD.
Hydrogen purity and replacement meter for power adjustment of electrostatic North America http://www.yokogawa.com/sg/ http://www.yokogawa.com/au/
generators precipitator efficiency YOKOGAWA CORPORATION OF AMERICA Korea
Georgia, U.S.A YOKOGAWA ELECTRIC KOREA CO., LTD.
http://www.yokogawa.com/us/ http://www.yokogawa.com/kr/
Infrared Gas Analyzers South America
YOKOGAWA AMERICA DO SUL LTDA.
China
YOKOGAWA CHINA CO., LTD.
BRAZIL http://www.yokogawa.com/cn/ Represented by:
http://www.yokogawa.com.br/ YOKOGAWA SHANGHAI INSTRUMENTATION CO., LTD.
IR100/IR200/IR400 NDIR Type Infrared Gas Analyzers SG700 Stack Gas Analyzer Europe http://www.ysi.com.cn/
YOKOGAWA EUROPE B.V. YOKOGAWA SICHUAN INSTRUMENT CO., LTD.
European Headquarters http://www.cys.com.cn/
Simultaneously THE NETHERLANDS Taiwan
measures NOX, SO2, http://www.yokogawa.com/eu/ YOKOGAWA TAIWAN CORPORATION
YOKOGAWA ELECTRIC CIS LTD. http://www.yokogawa.com.tw/
CO,CO2 and O2 with RUSSIAN FEDERATION
sampling system Vig-PMK-G·NL-07E
http://www.yokogawa.ru/
Printed in Japan, 805(KP) [Ed : 06/b]
IR100 IR200 IR400
Measuring Components
IR100: CO2, CO, CH4 IR200: CO2, CO, CH4, IR400: NO, SO2, CO2, CO, Subject to change without notice.
SO2, NO, O2 CH4, O2 All Rights Reserved, Copyright© 2001, Yokogawa Electric Corporation.