Product Overview

Emission Monitoring
Ambient Monitoring
Environmental and Process Data
Management Systems

smart solutions for combustion and environment


Introduction Monitor selection
The DURAG GROUP develops and manufactures DIN EN 14181 prescribes which characteristics In addition to the general data, such as de-
products in the field of environmental measur- automatic measuring equipment must possess,
sired measurand or measuring range, special
ing technology for measuring and monitoring and how they must be calibrated and main-
tained. In addition to the calibration function, account must be taken of the plant conditions
● dust concentration and opacity at the measuring location when selecting a
measurement inaccuracy - which plays a deci-
● total mercury concentration sive role in the validation of the measured val- suitable measuring device, especially in the
● flue gas volume flow ues obtained during continuous monitoring - is case of dust concentration measurement.
as well as evaluation systems for the calculation also determined from the data of the calibra-
Opacity
of emissions. tion. In addition, the requirements for the un-
certainty of the measured values obtained with A light beam sent through a mixture of gas and
The products are used worldwide in power gen- the measuring equipment, which are defined in particles is attenuated by absorption and diffu-
eration plants and the process industry, such as the EU directives relating to large combustion sion. The more particles are found in the light
e.g. fossil fuel power stations, waste incineration plants, waste incineration plants and waste co- beam, the stronger the opacity. The ratio of re-
plants, refineries, chemical processing plants, incineration plants, are checked using a method ceived light to initial light is a measurement of
cement works, the lime industry, the steel indus- described in the standard. the transmission or the reciprocal opacity.
try, filter and dust extraction plants as well as for
monitoring ambient air. Extinction
The DURAG Group is known for its high stan- QAL 1 – Testing the suitability of the By converting the transmission to extinction
dards of quality. DURAG has been ISO 9001 cer- equipment technology and after a gravimetric comparison measure-
tified for a number of years and has fully imple- ment the display is in mg/m3. For dust concen-
QAL 1 specifies the suitability of a measuring
mented the corresponding requirements. The trations this result is displayed in mg/Nm3 by
device by calculating the total measuring uncer-
products are manufactured to national, Euro- calculation with the reference units T, P, RF.
tainty according to EN ISO 14956 before installa-
pean and international standards.
tion, by taking account of all potential influ- Scattered light
The following are taken into account:
ences.
● VDI 2066 / VDI 3950 – German dust meas- A light source emits light which is diffused by
Devices that have passed the TÜV suitability test particles in the gas and recorded by a detector.
urement standard
and have been established as suitable measur- The scattered light principle is suitable for small
● EN 14181 – European quality assurance stan- ing devices generally fulfil the standards of dust loads to under 1 mg/m3. The relationship
dard for automatic measuring equipment QAL 1. between measured value display and dust load
● EN 13284 – European standard for determin- is determined by means of gravimetric compa-
ing small dust concentrations QAL 2 – Installation and calibration rison measurement.
● EN 14884 – European standard for determin- check
ing total mercury concentration Smoke spot number (soot)
Selection of the measuring location and correct Scattered light measurement with very low
● EN 12341 – European standard for determin- installation of the measuring device. Calibration
ing PM10 airborne dust measuring range.Smoke spot number 1 corres-
of the device using a standard reference me- ponds to approx. 100 μg/m3. A comparison
● ISO 10473 – International standard for beta thod, min.15 measuring points distributed over
measurement determines the relationship bet-
absorption method 3 days, determination of the calibration curve or
ween display and smoke spot number.
● ASTM D-6216.98 – American dust measure- curves in different operating conditions (fuels,
ment standard. load, etc.) and definition of the area of validity of Triboelectricity
the calibration curve. Triboelectricity results from friction between
Calculation of the total measuring uncertainty bodies or particles. If these charged particles
DIN EN 14181 of the measuring device. strike a measuring probe, an electron transfer
DIN EN 14181 defines three so-called quality as- takes place. The value of the charge is a measu-
surance levels (QAL) and an annual functional QAL 3 – Continuous monitoring rement for the dust mass flow rate. The relati-
test (AST) for automatic measuring systems: onship between measured value display and
● QAL 1: Requirement for use of automatic Regular checks of the zero and reference point dust concentration can be determined by a
measuring equipment that has had its suit- drifts during the plant operation by the operat- gravimetric comparison measurement.
ability tested (the test complies with DIN EN ing personnel should ensure reliable and cor-
rect operation of the measuring device. Dew point
ISO 14956)
Every gas mixture contains a defined quantity
● QAL 2: Installation of automatic measuring
AST – Annual inspection of humidity. The maximum possible saturation
system (AMS), calibration of AMS using the
humidity is dependent on the temperature: if
standard reference method (SRM), determina-
The calibration curve found in QAL 2 must be air is continuously cooled, with constant abso-
tion of measuring uncertainty / variability of
checked / confirmed annually by means of 5 lute air humidity the relative air humidity in-
AMS and check for observance of preset
parallel measurements. creases up to 100%. If the air is further cooled,
measuring uncertainties
the humidity condenses as water drops and af-
● QAL 3: Continuous quality assurance by the
operator (drift and precision of the AMS, veri- fects the measuring result in optical and triboe-
fication on control card) lectric measuring procedures.
● AST: Annual surveillance test including SRM Temperature
measurements to check the uncertainty of The ambient temperature of the measuring
the AMS values. head may be maximum 50°C. In optical sys-
tems, the purge air is also used as cooling air
and separates the hot exhaust gas through the
purge air buffer. In transmission systems, the
standard assembly connection can be used up
to an exhaust gas temperature of 200°C.
Beyond this, the connection must be extended
(approx. 1 mm / 1°C).
Pressure
The standard purge air blower can be used up
to a channel overpressure of 20 hPa. Beyond
this, special blowers are available. A flap valve
should be used in the event of overpressures.
2
Devices for measuring emissions and immissions
Total Ambient
Measurment Dust / Opacity Dust Soot Dust Dust Dust Mercury Dust
Measuring UV
principle Transmission Scattered Light Forward Scattering Tribo Beta Photometer Beta

DURAG Group D-R 220 D-R 290 D-R 300-40 D-R 300 D-R 800 D-R 820 F D-RX 250 F-904-20 HM-1400TR F-701-20
Device

TÜV ● ● ● ● in
preparation ● ● ● ●
US EPA ●
GOST ● ● ● ● ●
MCERTS ● ● ● ● ●
Korean ● ● ●
in-situ ● ● ● ● ● ● ●
extractive ● ● ● ●
Automatic zero
and control point ● ● ● ● ● ● ● ● ●
Automatic soiling
correction ● ● ● ● ● N/A N/A N/A N/A

Fail safe shutters ● ● ● N/A N/A N/A N/A

Range switching ● ● opt. ● ● ●


Remote control
unit ● ●
mg/m3 mg/m3 mg/m3 smoke spot mg/m3 mg/m3 mg/m3
Calibratable in wet wet number wet wet wet mg/m3 mg/m3 mg/m3
wet
Measuring 0-0.2...1.6 Ext 0-0.1...1.6 Ext 0-1...30 0-10...200 0-15...100 0-2...100 0-1...0-1000 0-45…500 0-0.1…10
3 RZ
ranges 0-20...100% mg/m3* mg/m3 mg/m3 mg/m3 wet mg/m3 μg/Nm3 mg/m3
Detection limit
@ stack Ø 1 m 20 mg/m3 10 mg/m3 0.01 mg/m3 0.06 RZ 0.2 mg/m3 0.2 mg/m3 0.01 mg/m3 0.5 μg/Nm3 N/A

Detection limit
@ stack Ø 5 m 8 mg/m3 2 mg/m3 0.01 mg/m3 0.06 RZ 0.2 mg/m3 0.2 mg/m3 0.01 mg/m3 0.5 μg/Nm3 N/A
Sample collection/
Heavy metal ● ●
analysis
* with measuring range switching up to approx. 300 mg/m3

Comparison of emission dust monitors according to application criteria

3
Optical dust and
opacity meter
New system for monitoring dust
emissions on smaller plants and in
process applications.

Features Measuring principle


optical measuring reflector
● In-situ measurement directly in the flue gas The device operates using the double-pass unit

flow method according to the auto-collimation prin-


● Digital operation with microprocessor ciple. The light beam traverses the measuring
distance twice. The attenuation of the light
● Adjustable limit value beam by the dust content in the measuring sec- supply box
● 2 contact switch outputs tion is measured and evaluated.
● Measuring value integral
4/15/64 seconds
● Internal event memory System components
● PC-interface for easy maintenance
● D-R 220 measuring head
● Modbus RTU interface
● Reflectors for measuring distances 0.4 to 10 m
● Measurement results shown as opacity or ex-
tinction ● Mounting flanges
● No weather protection covers needed. ● Supply box with purge air unit
● Zero point reflector.

Applications
Models Options
● Non-compliant device for smaller plants
● Heating stations, power stations ● System 1: for measuring sections up to 3 m ● Neutral density filters for linearity check
● Boiler plants in industry, barracks, hospitals, ● System 2: for measuring sections from 2.5 m ● Sighting scope
schools up to 10 m.
● Dust extraction and filter plants
● Process monitoring
● Filter monitoring.

opacity,
measurements accuracy <2% of measuring range
extinction
0–25/50/100% OP
measuring ranges detection limit <3% of measuring range
0–0.2/1.6 Ext
measuring transmission supply voltage 24 VDC, 0.4 A
principle

above dew point up to 200°C,


flue gas dimensions measuring head
optional up to 500°C,
temperature (H x W x D) 160 x 150 x 314 mm
depending on application

-50 up to +10 hPa, measuring unit 2.7 kg,


flue gas pressure weight
optional higher reflector 1,6 kg

duct diameter 400–10,000 mm supply box

ambient -20 up to +50°C purge air supply integrated


temperature
85–264 VAC, 46–63 Hz,
protection IP65 supply voltage 50 VA
dimensions
measuring output 0 / 4–20 mA / 400 Ohm 210 x 300 x 380 mm
(h x w x d)
2 relay outputs
digital outputs weight 13 kg
30 VA, max. 48 V/1A

digital inputs NA protection IP54


4
Optical opacity /dust
monitor
Standard system for plants with
small to medium dust concentra-
tions.

Features Measuring principle


● In-situ measuring procedure, continuous The device operates using the double-pass
measurement method according to the auto-collimation prin-
● Semi-conductor source with long service life ciple. The light beam traverses the measuring
distance twice. The attenuation of the light
● Super-wide band diode (SWBD), which pro- beam by the dust content in the measuring sec- optical measuring reflector
vides more stable measuring results in com- unit
tion is measured and evaluated.
parison to devices with conventional LEDs
● Powerful microprocessor technology
System components
● Measured value display on LC display in
opacity, extinction or in mg/m3 ● Mounting flanges
● Automatic function tests with correction of ● Measuring head
measured values in relation to soiling ● Reflector purge air unit
● Optics and electronics in a hermetically ● Control and display unit
sealed unit - no smoke gas can enter device
● Purge air unit.
● Easy adjustment without additional equip- control and
display unit
ment
● Low-maintenance thanks to optimal purge air
Options
conduction. ● Bus interface, e.g. Modbus or similar
● Automatic quick-closing shutters to protect the measuring head and the reflector in the event of
failure of the purge air
Applications ● Weather protection covers, for outdoor installation
Plants in which the dust concentration quantity ● Explosion proof design for EEx p, Zone 1 or Zone 2
needs to be measured, e.g.: ● With an additional display unit at the measuring location, the control and display unit can be in-
● Furnace plants with semi-anthracite coal, stalled in up to 1000 m distance away
brown coal, fuel oil and combined heating ● Temperature compensation through additional analog input
● Converter plants, asphalt mixing plants ● Special model for measuring distances up to 18 m with 2 purge air units
● Plants for cement manufacture. ● Filter set for sensitivity and linearity control.

measurements opacity, extinction detection limit 0.75% @ extinction 0–0.1

Approvals opacity: 0–20% ... 0–100%


switchable extinction: 0–0.1 ... 0–1.6 reference point <0.4% of measuring range/month
● Suitability-tested by the TÜV Cologne, measuring ranges dust: 0–80 mg/m3 ... drift
0–4000 mg/m3 1)
test report 936/801017
measuring
● Itemized in the list of suitable measuring principle transmission zero point drift <0.4% of measuring range/month
devices for continuous emission measuring. above dew point up to 250°C,
flue gas
● MCERTS. temperature optional up to 1000°C, depending supply voltage 95–264 VAC, 47–63 Hz, 30 VA
on application
-50 up to +20 hPa, dimensions measuring head
flue gas pressure optional higher (h x w x d) 363 x 185 x 398 mm
1 up to 12 m,
duct diameter weight 7 kg
optional up to 18 m
1)
ambient -20 up to +50°C, with reference to one meter of
remarks path length after gravimetric
temperature optional higher
calibration

protection IP65, Ex optional purge air supply

2 x 0 / 4–20 mA / 500 Ohm,


measuring manual or automatic measuring
outputs range switching, optional Modbus purge air quantity approx. 80 m3/h
RTU, Profibus DP

6 programmable relay outputs, 115/230 VAC, 50/60 Hz,


digital outputs supply voltage
permissable load 48 V / 0.5 A 0.37 / 0.43 kW

dimensions 350 x 550 x 500 mm


6 programmable potential free
digital inputs (h x w x d)
inputs weight 12 kg

accuracy <1% of measuring range protection IP65


5
Measuring device for Measuring principle
The D-R 300 / D-R 300-40 meters operate ac-
smoke spot number / cording to the scattered light method. The mod-
dust concentration ulated light from a Halogen lamp illuminates
the dust particles in the exhaust duct. The scat-
tered light reflected from these particles is
D-R 300: Extremely sensitive device measured and assessed.
for measuring smoke spot number.
Specifications
D-R 300-40: Especially sensitive
D-R 300
measuring device for the smallest
concentration of dust, in particular ● Measuring range: smoke spot number 0-3.
Limit value II can be set as delayed discon-
in waste incineration plants. nected contact
Features ● Calibration: VDI 2066, page 8.

● In-situ measurement directly in the flue gas


flow
D-R 300-40
● Automatic system tests and correction of ● Minimum measuring range 0-1 mg/m3 dust
measured values concentration. Other measuring ranges up to
300 mg/m3 can be set (optional automatic
● Self-calibration in 4-h cycle
switching of measuring ranges 1:3:9)
● Optics and electronics in a hermetically
● Calibration: VDI 2066, page 7.
sealed unit - no smoke gas can enter device
● Maintenance-friendly, thanks to optimal System components
purge air conduction in front of the heated
optical end plates ● Measuring head
● Direct access to all parameters via the opera- ● Mounting flange quick-closing
shutter (optional)
tor display ● Control and display unit
● Automatic measuring range selection in ac- ● light trap(s)
measuring head

cordance with 17. BImSchV. in relation 1:3:9*. light trap


● Purge air unit.

Applications control and


display unit
Options
● Smoke spot number measurement in fur-
naces designed for light fuel oil ● Automatic measuring range selection for dust
measurement in accordance with
● Fine dust measurements in processes 17. BImSchV (D-R 300-40) 2nd light trap
● Waste incineration ● Weather protection covers
(D-R 300 only)

● Filter monitoring and emission-value measur- ● Quick-closing shutter to protect measuring


ing in waste incineration and power plants*. device in the event of failure of the purge air purge air unit
supply
Approvals ● Halar flange coating.
● Suitability-tested by the TÜV Cologne,
test report 936/800002
● Suitability-tested by the TÜV Cologne,
test report 936/801004*
● Itemized in the list of suitable measuring smoke spot number (D.R 300)
measurements detection limit <1% measuring range
dust concentration (D-R 300-40)
devices for continuous emission measuring
D-R 300:
● MCERTS. smoke spot number 1–3 (5)
D-R 300-40: dust concentration reference point
measuring ranges <0.2% of measuring range/month
0–1 mg/m3 ... 0–30 mg/m3 1), drift
*D-R 300-40 optional 0–300 mg/m3 with range
switching
measuring back scattering zero point drift <0.2% of measuring range/month
principle
obove dew point up to 320°C,
flue gas optional up to 600°C, depending supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA
temperature on application
dimensions measuring head
flue gas pressure -50 up to +20 hPa (h x w x d) 565 x 310 x 200 mm

duct diameter 0.3 to 4 m weight 18 kg

ambient -20 up to +50°C remarks 1)


temperature after gravimetric calibration

protection IP65 purge air supply

measuring 2 x 0/4–20 mA/500 Ohm, optional


outputs measuring range switching purge air quantity approx. 80 m3/h
3 relay outputs, 115 / 230 VAC, 50 / 60 Hz,
digital outputs supply voltage
permissable load 250 V / 100 VA 0.37 / 0.43 kW
dimensions
digital inputs 1 potential free input (h x w x d) 350 x 550 x 500 mm
weight 12 kg

accuracy <1% of measuring range protection IP54


6
Dust monitor
Innovative measuring device with
laser technology to monitor small
to medium dust emission according
to the new European regulations.

Features Measuring principle System components


● Integrated display: Measuring value, The D-R 800 device works according to the prin- ● Measuring lance
threshold value, parameter in probe ciple of forward scattering. The concentrated ● Supply unit with integrated purge air supply
● In-situ measuring procedure with continuous and modulated light of a laser diode penetrates
the measuring volume. The forward-scattered ● Mounting flange 130 / 240 / 500 mm.
measurement
light largely reflected from dust particles is
● High sensitivity measured and assessed. Options
● Easy installation on one side of the duct
● Weather protection cover
● Can also be deployed in thick-walled
stone/insulated channels ● Temperature compensation through addi-
tional analog input.
● Long lifetime, as there are no moving parts
inside the duct
● Hermetically sealed electronic housing
against exhaust gas
supply unit with
● Parameterisation and operation with key- integrated purge air
board plus easily readable display directly on supply
device or via bus interface
● Automatic function test with soiling correc- evaluation unit
tion measuring lance
● Two analog outputs with adjustable measur-
ing ranges
● Automatic switching of measuring ranges
according to 17. BImSchV.
RS 485 and
analog
current
output
Applications
● Power stations
● Cement plants, the metallurgy and wood in-
dustries, chemical industry etc.
● Waste incineration plants
● Monitoring of dust filter plants.

Approvals measurements dust concentration accuracy <1% of measuring range limit

● Suitability-tested by the TÜV Cologne, measuring ranges 3


0–10 mg/m ... 0–200 mg/m 3 1)
detection limit <0.5% measuring range
test report 936/21205307/A
measuring reference point
● Itemized in the list of suitable measuring principle forward scattering drift <0.7% of measuring range/month
devices for continuous emission measuring flue gas <0.15 % of measuring range/
above dew point up to 220 °C zero point drift
● MCERTS pending. temperature month

flue gas pressure -50 up to +10 hPa supply voltage 85–264 VAC, 47–63 Hz, 50 VA

measuring lance:
duct diameter 0.4–8 m dimensions 160 x 160 x 600 / 1000 mm
pending
(h x w x d) supply unit: 380 x 300 x 210 mm
probe length measuring lance: 7 kg
473 / 787 mm weight
(from flange) supply unit: 13 kg
ambient
temperature -20 up to +50°C purge air supply integrated into supply unit

protection IP65

measuring 2 x 0 / 4–20 mA / 500 Ohm,


outputs Modbus RTU (RS485)
4 relay outputs, programmable,
digital outputs permissable load 24 V / 25 VA
2 potential free inputs, 1)
digital inputs programmable remarks after gravimetric calibration
7
Dust concentration Measuring principle
A defined partial current is withdrawn from the
monitor for wet exhaust gas current. This partial cur-
gases rent is continuously heated and dilut-
ed with clean, heated air directly in
the sampling probe. This immediately
Sensitive system for continuous ex- lowers the relative moisture and
aerosols get evaporated in the heat-
tractive dust concentration meas- ed probe. The partial current is opti-
urement in accordance with the cally measured in the measuring
scattered light principle.
chamber.
The signal is corrected by the meas-
ured dilution ratio and is thus a meas-
ure of the dust content of the ex-
Features haust gas.
● Compact design The system comprises a special sam-
● Very low maintenance requirement pling probe, the laser dust monitor, a
gas conditioning unit (dilution, tem-
● In-situ measuring method with continuous pering), an injector, two fans and an
measurement electronic evaluation unit.
● High sensitivity The sampling probe and the measur-
● No laborious device adjustment. ing chamber form an assembly. The electronic
evaluation unit and one blower for operating
the injector and one for generating the diluting
air are mounted together on a rack frame.
probe electronics
Applications System purge air
The D-R 820 F is used for measuring dust con- components for probe
centration in wet gases.
Potential applications e.g.: (filter optional)
● Measurements in saturated gas downstream probe heating
of desulfurization plants
● Downstream of wet cleaning plants
injector
● Waste incineration plants
● Technological processes.
control valve measuring
solenoid valve chamber

exhaust

diluting air diluting air fan


heating injector air fan

Measuring range Rack frame with control unit


0 ... 15 (max. 100) mg/m3 600 x 1750 x 550 mm
dust in operation dimensions
higher on request (W x H x D)
exhaust gas absolute moisture ≤40%, space 1100 x 1750 x 1100 mm
moisture limit 250 g/m3, requirements (W x H x D)
value relative moisture = 100%

Probe unit weight approx. 90 kg


dimensions 600 x 1050 x 1500 mm (W x H x D),
including probe protection class IP55
length 1000 mm
ambient
weight approx. 40 kg -20 ... 50°C
temperature
230/400 V, 50 Hz, 3x16 A, 3 L, N, PE
probe material stainless steel, Hastelloy as option power supply others optional
protection class IP65 Connections on control unit
ambient 4x 4 ... 20 mA, galvanically isolated
-20 ... 50°C current outputs
temperature with common ground
measuring gas max. 280°C (higher on request) load max. 1 kOhm
temperature
measuring air flow
rate 8–10 m3/h digital contacts 6x max. 35 V 0.4 A

optional via switching contact to


DN 80 PN 6 special version
flange digital input externally change between
tube Ø100 mm measuring/purging

terminal contacts max. 2.5 mm2


8
Combined probe
sensor
Single rod measurement probe for
simultaneous measurement of
- Dust concentration [mg/Nm3]
- Volume flow [Nm3/h]
- Temperature [°C] Measuring principle
- Absolute pressure [hPa]. ● The tribo probe measures the electric charge
of the incident particles.
● The measurement of the volume flow is
Features based on the mechanical action principle. The
probe has two separate chambers, between
● Only one probe / installation opening in the which a differential pressure builds up under ● Dust concentration is calculated from the
exhaust gas channel flow. triboelectric measuring signal and the vol-
ume flow. To this purpose in calibration, you
● Compact design, no moving parts, no con- ● The absolute pressure in the flue gas is receive the necessary parameters for the rele-
sumable parts measured by a pressure transmitter in one vant speed ranges, which form the basis for
● Continuous conversion to normalised dust chamber of the probe. calculating dust concentration. The raw data
concentration in mg/Nm3 and to normalised ● The temperature is measured directly in the that are also measured for gas temperature
volume flow in Nm3/h centre of the flue gas flow in a separate cham- and absolute pressure are used to calculate
● LCD display in mg/Nm3, Nm3/h, °C and hPa, ber within the probe with a temperature sen- the standard dust concentration and the stan-
one analog output for each measurement sor. dard volume flow (wet).
value
● Parameterization at the control unit without System components
the need of a PC or other tools
● Remote connection of control and evaluation
unit via two-wire bus interface up to 1000 m. probe transmitter differential control and
pressure evaluation unit
transducer

Applications
● For measurements in accordance with TI Air
(Technical Instructions for Maintaining Air
Purity), 13., 17. and 27. BImSchV
✖ Not suitable for use behind electrostatic pre-
cipitators. Please consult us.
max. 1000 m

Approvals
● Suitability-tested by the TÜV Cologne, Options ● Automatic cyclic probe back purging for high
test report 936/800006/A ● Weather protection cover dust concentrations
● Itemized in the list of suitable measuring ● Switch-over cock for back purging / zero ● Hastelloy probes for corrossive gases
devices for continuous emission measuring point control ● Purge air connection at flange.
● MCERTS.
dust concentration, volume flow,
measurements detection limit <2% of measuring range
absolute pressure, temperature

0–10 ... 0–500 mg/Nm3


0–9,999,999 Nm3/h 1) reference point
measuring ranges <1% of measuring range/month
0–200°C, optional 0–350°C drift
900–1,300 hPa
measuring dust: tribo electric
principle volume flow: differential pressure zero point drift <1% of measuring range/month

above dew point up to 200°C,


flue gas optional up to 350°C, supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA
temperature flue gas humidity <80%
dimensions probes: 180 x 180 x (340 + probe
flue gas pressure -200 up to 200 hPa (h x w x d) length) mm
probe length 250, 400, 700, 1000 mm
probe 9.5 kg
duct diameter 0.3–4 m weight electronics 22 kg
ambient probe back
-20 up to +50°C purge air supply 3 bar
temperature purging (option)
insulator purging continuous purge air supply
protection IP65 (option) approx. 2 m3/h
measuring 4x 0 / 4–20 mA / 500 Ohm,
outputs Modbus RTU (RS485)

digital outputs 7 relay outputs,


permissable load 250 V / 100 VA
digital inputs 6 potential free inputs 1)
flue gas velocity >5 m/s
remarks concentration after gravimetric
accuracy <2% of measuring range calibration
9
Filter monitor
Triboelectric filter monitor for
efficiency monitoring after filter
plants and for continuous dust
measuring in dry emissions.

Features Measuring principle


● Compact and rugged design The filter monitor uses the triboelectric effect to D-FW 230 filter monitor
● Good price/performance ratio determine dust loads in flowing gases. The elec- ● D-FW 231 measuring probe Probe rod length
trical charge which the dust particles experi- 400 mm
● Ideal for monitoring bag filters ence due to friction is picked up by a probe pro-
● Minimal maintenance required truding into the dust channel and converted in- ● D-FW 230-B control unit with digital display
to a measuring signal by electronics. The 115/230V 50/60 Hz.
● Early detection of filter malfunctions
measuring signal is proportional to the dust
● Savings in cost, as no preventative filter ex- concentration and is calibratable at a constant
change is necessary. D-FW 235 mobile filter monitor
gas speed.
● D-FW 231filter monitor with 80, 250 and
400 mm probe length in a system case includ-
System versions ing a 3-channel paperless recorder.
Applications
D-FW 231 measuring probe
● Power stations ● With complete electronics in the probe
● Bag filter plants of all types ● Probe rod length 400 mm
● Dust extraction plants in the production in- ● Fitted via 1“(G1) thread
dustry
● Waste incineration plants
● Crematoriums
✖ Not suitable for use directly behind electro- probe control unit
static precipitators.

Approvals
● Suitability-tested by the TÜV Hamburg,
test report 98CU026
● Itemized in the list of suitable measuring
devices for continuous emission measuring.

● Weather protection cover


Options
● Various mounting options (flange, connection
● Measuring gas temperature up to 500°C piece)
● Ex version D-FW 240/Ex ● Probe rod lengths 80, 250, 700 mm

measurements dust mass flow detection limit <2% of measuring range/month

0–100% reference point


measuring ranges <0.3% of measuring range/month
(flue gas velocity >5 m/s) drift
measuring tribo electric zero point drift <0.3% of measuring range/month
principle
above dew point up to 200°C,
flue gas 24 VDC, 5 VA
optional up to 500°C, supply voltage
temperature 115 / 230 VAC, 50 / 60 Hz, 10 VA*
flue gas humidity <80%
dimensions probe: 180 x 80 x (270 + probe
flue gas pressure -500 up to +500 hPa (h x w x d) length) mm
probe length 80, 250, 400, 700 mm
probe: max. 4.5 kg
duct diameter 0.3–4 m weight control unit: 3 kg
ambient -20 up to +50 °C
temperature

protection IP65

measuring 0 / 4–20 mA / 500 Ohm


outputs
1 relay output,
digital outputs* permissable load 250 V / 100 VA

digital inputs* 2 potential free inputs

accuracy <2% of measuring range remarks *D-FW 230 only


10
Extractive beta gauge Measuring principle
Determination of the dust concentration by
particulate monitor measuring the absorption of beta rays emitted
by a radioactive emitter by particles collected
from an exhaust gas flow.
Dust monitor especially for wet flues
- emission temperature under dew
point - and for the monitoring of
blast furnace gas. System components
● Heated sample probe (material 1.4571 or tita-
nium), with or without dilution
● Heated sample line in 1.4571
● Filter tape in gas-tight filter holder
● 14C emitter and detector (Geiger-Müller
Features counter)
● Automatic zero correction ● Sample gas cooler
● Pre-calibrated, unaffected by particle size, ● PLC control, also for calculating the concen-
colour or moisture tration from the dust content.
● Sample gas flow regulated at 1 - 3 m3/h
● Isokinetic sampling
● Optional dilution sample probe for high con-
centrations or after wet scrubbers
● Heavy metal analysis possible
● Special model with measuring chamber purg- sample probe, nozzle
pressurized air
ing and CO-TLV monitoring during dust moni-
toring of blast furnace gas. tape-filter printer PLC
(option) 4–20mA
STATI
Applications cover foil
(Option)
counter tube
C-14 source
total flow
● Coal and oil-fired power stations vacuum pump
filter adapter with bypass total flow
● Waste incineration plants (municipal waste, controller
dilution
Venturi gas Venturi
industrial waste and hazardous waste) supply reel nozzle nozzle
● Sewage sludge incineration plants
● Emission dust measurement after wet scrub- filter advance take-up reel sample cooler with
bers or in very wet exhaust gases stepping automatic drain
motor
● Heavy metal analysis
● Measurement of very low dust concentrations dilution gas control valve
in emissions
Options
● Emission dust measurement in inaccessible ● Special design F-904-20/BFG for measurement of the dust concentration in toxic and explosive
flues with small diameter blast-furnace gas with shut-off valves for the sample gas during filter transport and with purge gas
(usually nitrogen) for line back purging. A CO detector is also provided, which closes all gauge con-
● Dust concentration measurements in process
nections to the process gas if the CO threshold limit value is exceeded and gives an alarm
applications.
● Filter tape printer and protective sheet for specimens in heavy metal analyses.
Approvals
● Suitability-tested by the TÜV Essen,
test report 3.5.2/209/88-338529
● Itemized in the list of suitable measuring
devices for continuous emission measuring
measurements dust concentration detection limit <0.3 mg/Nm3
● Type approval: HH 1/98
● PTB test certificate no. 6.22-R202. measuring ranges 0–1 ... 0–1000 mg/Nm3
reference point <1% of measuring range/month
drift
measuring beta ray absorption zero point drift automatic zero point correction
principle
flue gas 0–250°C, supply voltage 115 / 230 VAC 50 / 60 Hz, 5 kVA
temperature optional up to 500°C
dimensions
flue gas pressure -100 up to +100 hPa 1600 x 800 x 800 mm
(h x w x d)

duct diameter >0.5 m weight 300 kg

ambient 0 up to +50°C, cooler optional purge air supply pressurized air 6–8 bar
temperature
IP43 (with filter blower),
protection upgradable to IP54
measuring 2 x 0 / 4–20 mA / 450 Ohm
outputs
11 relay outputs,
digital outputs permissable load 24 V / 25 VA

digital inputs 2 potential free inputs

dust monitoring of blast furnace


accuracy <5% of measuring range option gas
11
Automatic sampling
device for gravimetric
dust measurements
Reference measuring system for
calibration of dust measuring in-
struments [mg/Nm3] according to
DIN EN 13284-1 and VDI 2066.

Features Measuring principle


● Automatically registers all relevant parame- The D-RC 80 automatically extracts a partial gas After manual input of the weighed filter mass
ters necessary for dust measurement, stream isokinetically from the measuring gas the D-RC 80 computes the dust content of the
for example: duct. This partial gas stream is sucked through a sample in the operational and standard state.
- humidity of the measuring gas filter in which the contained dust is deposited. The values can be printed by the integrated
- velocity in the measuring gas duct At the end of the measurement the filter is con- printer or put out through the built-in interface..
- temperature ditioned and weighed.
- pressure
measuring points temperature Dust measurement probe head
● Compact system consisting of probes and for differential pressure sensor
control unit
● Variable applications through probe adapta-
tion to plant conditions
● On site diagnosis of the measured values on
high resolution graphics display
● Stores up to 125 measurements measuring point for dust
sample container
● Automatic calculation of the concentration
in mg/Nm3 after entering the filter weights
● Built-in log printer
● Serial PC interface
control unit with
● Automatic calculation of the correct nozzle display and printer
size
● Calculation of furnace efficiency through the
standardization program, as required in China probe for dust measurement flue gas
and other Asiatic countries differential pressue
flue gas temperature
● Excellent price/performance ratio.

probe for humidity measurement


humidity

Measurements General technical data

ambient
dynamic pressure 0 ... 1.500 Pa -20 ... +50°C
temperature
dew point
static pressure -30 ... 10 kPa min. +5 K
difference
barometric 950 ... 1050 hPa mains 230 VAC / 50 Hz, 200 VA
pressure

flue gas pressure -50 up to +20 hPa, data storage 125 samples
optional higher capacity
volume flow container measuring container:
Display main menu 10 ... 50 l/min
(sampling) dimensions 400 x 370 x 200 mm, approx. 15 kg
temperature (w x h x d),
0 ... 99°C weight accessories container:
(before flowmeter)
400 x 370 x 200 mm, approx. 6 kg
flue gas 0 ... 400 °C
temperature probe case:
1570 x 120 x 230 mm,
humidity 0...40 Vol% approx. 9.5 kg
installation depth:
response time <8 s humidity probe max. 650 mm
dust probe max. 1350 mm
12
Beta gauge particulate
monitor
A measuring device for the continu- Measuring principle
ous monitoring of the smallest The measuring principle of the F-701-20 am-
concentration of particles in the bient dust monitor is based on the absorption
ambient air (fine dust). of the beta rays (electrons) emitted by a radio-
active emitter through particles collected from
an ambient air flow. In the F-701-20 the pulse
rate of the unloaded filter tape is measured be-
fore each collecting cycle, then dust is collected
on this precise filter spot over a pre-defined
period, and finally the pulse rate of the loaded
Features filter tape is measured. The difference between
the two pulse rates is evaluated in the device
● C-14 method, no measurable decrease in
and displayed as dust concentration in μg/m3.
activity
● Lowest radioactivity of all beta gauges, usable
without licence, or disclosure
● Automatic zero correction
● Pre-calibrated, no site-specific calibration
required secondary tube sampling probe,
heating sample inlet
● Mass-flow controlled sample flow 1m3/h (option)
● Extraction of a constant sample flow, irrespec-
tive of the ambient temperature
Options evaluation,
● Repeated collection on the same spot, col- control
lected particles available for heavy metal
interface
analysis
counting tube
● RS-232 interface and analog output, status
signals C-14 source
protective foil filter housing
(option)

filter tape printer


Applications measured
value
strip
chart
(option)
supply reel
printer recorder
● Immissions measuring systems for monitor- stepper motor
for filter feed
ing fine dust vacuum
pump
● Mobile immissions-measuring sample
volume
● Dust measurement in health and safety appli- PC: read/write data flow
cations from/to instrument flow meter
bypass
● Interior dust measurements control valve

● Measurement and collection of dust particles


for heavy metal analysis Options
● Long-term background studies in ambient
Further sample inlets:
dust concentration
● PM-2.5 (accordant EN 12341)
● Dust measurement and collection at problem
sites and repositories ● PM-10 (according to EN 12341)
● Dust measurement for secondary emission of ● Total dust (according to VDI 2463)
repositories (e.g. coal).
● Dust measurement in supply air and exhaust
measurements dust concentration accuracy <2% of measuring range
ducts.

measuring ranges 0–0.1 ... 0–10 mg/m3 detection limit <0.001 mg/m3
Approvals
● Suitability-tested by the TÜV Munich, measuring reference point
test report 720349 beta-ray absorption <1% of measuring range/month
principle drift
● Itemized in the list of suitable measuring
devices for continuous emission measuring. ambient 0 up to +50°C zero point drift automatic zero point correction
temperature

230 VAC / 50 Hz, 110 V / 60 Hz,


protection IP20 supply voltage 400 VA

measuring dimensions 320 x 450 x 500 mm,


outputs 2 x 0 / 4–20 mA / 500 Ohm (h x w x d) 19“-rack mount / desk unit

8 relay outputs,
digital outputs permissable load 24 V, 12 VA weight 26 kg

digital inputs 3 potential free inputs probe tube length standard 2 m


0.5–5 m possible
13
Total mercury analyser
Measuring device for fully-automatic
and continuous mercury analysis in
smoke gas (without wet chemistry).

Features Measuring principle


● Maintenance-free (6 months) dry reactor In the HM 1400 TR total mercury analyser the
● High operational safety sample gas is converted into mercury vapour by
a combination of thermal and dry chemical
● Easy maintenance treatment. This is then continuously measured
● Low cross sensitivities in a photometer. The probe gas flow is meas-
● Easily legible LC display. ured after a gas cooler at 2°C. The concentration
is calculated and displayed as „dry flue gas“.

System components Options


Applications
● sampling probe ● Larger measuring range with dilution device
● Waste incinerations (municipal waste, indus- ● sampling line
trial waste, hospital waste) ● Top-mounted cooling device
● measuring device. ● Automatic probe back purging device, dilu-
● Sewage sludge incineration
tion device for gas sample
● Hazardous waste incineration
● Integrated system to generate calibration gas.
● Steel plants with scrap metal preparation
● Contaminated soil burning plants
● Crematoriums
● Mercury mines and refineries
● Fluorescent light bulb recycling plants.
heated
sample probe

Approvals pump
thermocatalytic
● Suitability-tested by the TÜV Hamburg, reactor Hg-
photometer
test report 00 CU 014 zero gas liquid
● Itemized in the list of suitable measuring filter
calibration
watchdog
devices for continuous emission measuring reactor
gas/liquid
● MCERTS. separator
option

calibration condensate
standard

measurements total mercury detection limit <1 μg/Nm3


reference point
measuring ranges 0–45 ... 0–500 μg/Nm3 <2% of measuring range/month
drift
measuring UV-absorption zero point drift automatic zero correction
principle
230 VAC, 50 Hz, 1200 VA,
flue gas 0–250 °C supply voltage sample probe: 650 VA,
temperature sample line: 100 VA/m
dimensions cabinet
flue gas pressure -50 up to +50 hPa (h x w x d) 1600 x 800 x 500 mm
duct diameter >0.5 m weight 220 kg
ambient +5 bis +30°C purge air supply pressurized air 3–6 bar
temperature
protection IP40 (IP55)
measuring 2 x 0 / 4–20 mA/500 Ohm
outputs
4 relay outputs,
digital outputs permissable load 250 V, 100 VA

digital inputs 1 potential free outputs

accuracy <1% of measuring range


14
Volume flow
measuring
system
Measuring system to measure flow
rate in dry emissions with a probe
using the differential pressure prin-
ciple. Probes
● Probe 1: 0.4–2 m
● Probe 2: up to 4 m
● Probe 3: up to 8 m.
Features Measuring
● Measurement of emission speed principle System components
● Calculation of volume flow at standard condi- The D-FL 100 measuring system operates accor- ● Mounting flange
tions with the evaluation unit D-FL 100-10 ding to the differential pressure principle. The ● Flow probe
(optional) probe has two separate chambers, between ● Counter-support
which the flow builds up a differential pressure. ● Differential pressure transducer
● Adjustable parameters Taking account of the other flow parameters ● Cross-over cock
● Automatic back purging device (optional) such as, e.g. absolute pressure and temperature, ● Probe adapter.
● Versions with or without counter-support and the volume flow can be converted from opera-
for point measurement. ting to standard conditions with the help of the
D-FL 100-10 microprocessor evaluation unit.
Options
● Microprocessor evaluation unit D-FL100-10
● Absolute pressure transducer
Models ● Temperature transducer
Applications
● D-FL 100 probe assembly ● Weather protection covers
● Volume flow measurement at high tempera- with assembly of measuring transducer on ● Automatically controlled back purging device
tures the probe (not for probe 3) ● Special designs in other materials for applica-
● Plants with large or small flue cross-sections tions with particularly aggressive exhaust gas-
● D-FL 100 hose assembly es or high gas temperatures
● Volume flow measurement at high pressure. with the measuring transducer connection ● dP-transducer in Ex-version.
via hose line.
differential micropro-
pressure cessor
transducer evaluation
Approvals unit

● Suitability-tested by the TÜV Hamburg, flow 4 ... 20 mA


test report 128CU11650 4 ... 20 mA
● Itemized in the list of suitable measuring 4 ... 20 mA
devices for continuous emission measuring. cross-over
cock
● MCERTS. absolute temperature
pressure transducer
transducer (optional)
(optional)

flow probe

flow direction

measurements flue gas velocity, volume flow 1) accuracy <2% of measuring range

measuring ranges 0–3000000 m3/h / 3–40 m/s detection limit <3 m/s

measuring reference point


differential pressure <0.5% of measuring range/month
principle drift
flue gas above dew point up to 400 °C, zero point drift <0.5% of measuring range
temperature optional up to 800 °C
-700 up to 1000 hPa, optional 14–45 VDC
flue gas pressure supply voltage
higher 115 / 230 VAC, 50 / 60 Hz, 50 VA 2)
dimensions probe: 380 x 160 x (300 + probe
duct diameter 0.4–8 m (h x w x d) length) mm
ambient -20 up to +50 °C weight 32 kg + 6,8 kg/m probe length
temperature
6–8 bar for back purging if
protection IP65, Ex optional purge air supply neccessary
measuring
outputs 0 / 4–20 mA / 500 Ohm 2) 1)
optional pressure and
remarks temperature correction
3 relay outputs, 2)
only with evaluation unit
digital outputs permissable load250 V, 100 VA 2)
15
Volume flow
measuring
system
Measuring system for ultra-sonic
measuring of velocity and volume
flow, especially for wet and aggres-
sive smoke emissions (waste incin-
eration).

Features Measuring Options


● In-situ measuring method principle ● Modbus interface
● Measurement possible below dew point and The D-FL 200 ● Temperatue transducer
for high dust concentrations measuring ● Absolute pressure
● Continuous measurement of normal volume system transducer
flow and gas velocity works ac-
cording to ● Weather protection covers
● Automatic zero point and reference point the ● Purge air sensor with poten-
control acoustic tial free error contact.
● Direct connection for temperature and pres- transit time
sure correction differential method. Ultrasonic trans-
● Parameter input via keyboard or PC ducers mutually send and receive short
pulses with and against the gas flow di-
● Continuous temperature measuring. rectionwhich affects their transit time. The
volume flow is calculated from the differ-
ence of transit times.
Applications System components
● Volume flow measuring at low speeds ● 2 mounting flanges (Mat. 1.4571) ● Evaluation unit D-FL 200-10 with housing
● Plants with damp and/or aggressive exhaust ● 2 measuring heads ● Purge air unit for cleaning and cooling the
gas, e.g. in waste incineration plants. sensors.
temperature
● Volume flow measurement at high dust con- transducer measuring head
tent. (optional)
duct
absolute
pressure
transducer
Approvals (optional)
purge air
● Suitability-tested by the TÜV Hamburg,
test report 99CU019
● Itemized in the list of suitable measuring
devices for continuous emission measuring evaluation unit

● MCERTS.

purge air

measurements flue gas velocity, volume flow 1), detection limit <0.3% of measuring range
temperature
3
0–3000000 m /h / 0–40 m/s reference point
measuring ranges <0.3% of measuring range/month
0–400°C drift
measuring acoustic propagation delay zero point drift <0.2% of measuring range/month
principle
flue gas 0–200 °C, optional higher supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA
temperature
standard measuring head:
flue gas pressure -50 up to +20 hPa, optional higher dimensions 190 Ø x 570 mm
duct diameter 0.7–10 m, temperature dependent weight 17 kg
1)
ambient optional pressure and
-20 up to +50 °C remarks
temperature temperature correction
protection IP65 purge air supply
measuring 2 x 0 / 4–20 mA / 500 Ohm,
outputs optional Modbus RTU, Profibus DP purge air quantity approx. 80 m3/h
3 relay outputs, 115 / 230 V, 50 / 60 Hz,
digital outputs supply voltage
permissable load 250 V, 100 VA 0.37 / 0.43 kW
dimensions 350 x 550 x 500 mm
digital inputs none weight 12 kg
accuracy <2% protection IP54
16
Environmental and Approvals Data security
● Suitability-tested by TÜV Munich, test report ● Paperless data storage to replace recorders
process data 24108990 in accordance with German TA-Luft, and printers is possible through integrated
management system 13., 17., 27. 30. and 31.BImSchV as well as the
European Directives 2000/76/EC for waste in-
data security, which is guaranteed on several
levels in the system
cinerators and 2001/80/EC for large combus- ● Intermediate storage of the raw input values
Modular system for continuous tion plants, considering EN 14181. at minute intervals in data communication
acquisition, long-term storage, unit D-MS 500 KE
calculation and visualisation of Measured data recording ● Double data storage on two separate hard
environmental and process data. disks in a RAID1 set
● Analog/digital inputs
- as sub-rack with intermediate data storage ● Storage of analog raw values at second inter-
- or as local modules vals
● Data transmission via bus systems, Modbus, ● Data backup on external redundant drive.
Profibus,TCP/IP or other interfaces.
Features
Internet/Intranet connection
● Instrument for monitoring legally prescribed Data sources
limit values and recording their observance ● Data transfer to an Internet server with HTML
● Emission data standard masks via standard software
● Emission monitoring and remote data trans- (MS-Internet-Explorer)
mission to the authorities ● Immission data
● Password-protected control of daily emission
● Adjustable to any plant size through to com- ● Meteorological data
values including classification records.
plete assessment of complex industrial sites ● Water data
● Continuous monitoring of 1 to 320 compo- ● Process data.
nents per system workstation Visualisation
● Interconnection of any number of compo- Data export ● Measured data recording according to official
nents via data networks. regulations
● Data interface to MS-Excel with option of fur-
● Classification tables, daily, monthly and annu-
ther measured data evaluation, e.g. for fulfill-
al records
ment of environmental protection officer’s re-
porting duties ● Representation of current, prognostic and his-
toric measured data in bar/chart form
● Measured data can be transfered to authori-
ties via standard remote communication or ● Pollutant compensation, characteristics curve
via internet and correlation
● Merging of measured data e.g. for greenhose ● Automatic alarm and information system.
emission trading
● Remote service interface for fast and cost
effective service.

17
Emissions evaluation
computer with solid
state drive
Economically priced all-in-one
module with modern flash memory
technology instead of hard disks.

Features
● Freely parameterisable
● Independently operating module for acquisi-
tion, long-term storage, calculation and visu-
alisation of environmental and process data
● Component of the modular D-EMS 2000 sys-
tem
System Overview
● Instrument for monitoring officially pre-
scribed limit values with automatic logging The system provides the following screens:
● Continuous monitoring of 1 to 64 compo- Parameterisation
nents connected via bus communication or System adaptation in accordance with licensing
hard wired requirements and orders
● „All-in-one“ system no additional evaluation Information
PC required Group-oriented event display with commentary Options
option and colour status information
● Can also be used as a module of the complete Three device types are available
D-EMS 2000 system. Evaluation
Display of current and historic data in bargraph ● Compact system in 19“ 3HU rack
and line diagrams ● Desktop version with
Logging monitor/keyboard/mouse
Applications Classification protocols and individual values in ● 19“ plug-in unit with pullout keyboard / dis-
● Emissions evaluation computer for small to daily, monthly and annual tables play unit
medium-sized installations in energy and
heat generation, for waste incineration plants
and in crematoriums as well as for
installations in the chemical and cement in-
dustry.

Approvals
● Suitability-tested by TÜV Munich, test report
24108990 in accordance with German TA-Luft,
13., 17., 27. 30. and 31.BImSchV as well as the
European Directives 2000/76/EC for waste in-
cinerators and 2001/80/EC for large combus-
tion plants, considering EN 14181.

Device types - Compact system in 19“ 3HE rack


- Desktop version with monitor/keyboard/mouse
- 19“ plug-in unit
Computer Power PC with Linux operating system,
1 GByte RAM and 4 GB Solid State Flash Drive
Data Security Protected storage of all official data including protocols for all legally required
periods on external hard disk or server
Analogue/digital inputs: 8/15 per card max. 6 cards
Inputs / outputs Analogue outputs: 8 per card max. 4 cards
Digital outputs: 16 per card max. 4 cards
Capacity of the system max. 11 boards

(Modbus, Profibus, Elan)


Connection of bus systems Analogue/digital inputs: 64/128
Analogue/digital outputs: 64/128

Interfaces 2x Ethernet RJ 45
4x USB 2.0
DCF 77 aerial socket BNC
Analogue modem/ ISDN RJ 45
2x RS 232
1x RS 485 (up to 3x RS 485 also optionally possible)
Operating voltage 115/230 VAC / 50/60 Hz / 100 VA
18
D-QAL
Software modules for CUSUM control card with detailed
information about precision and
the complete drift as well as the decision for
readjustment
D-EMS 2000 system
D-QAL: Documentation of AMS

D-PM.www
Provision of emission data for person in charge
via Internet
D-EFÜ.www
Provision of emission data for the authority via
the Internet
D-RWS
Storage of raw values with a resolution of 1 s
D-RED
External redundant storage of measured values
and logs
D-EVA-Win
Visualisation software for workstation PCs in D-QAL:
customer’s data networks Calculation sheet for CUSUM
cards
D-PM.MS
Direct access by MS-Excel to the D-EMS 2000
database
D-EMS CDM Internet
D-QAL Module
Automated calculation of drift and precision, To inform person in charge about the
creation of CUSUM cards as well as complete details of current and historical data
(measured and evaluated values) as
documentation of the AMS. well as the results of all realised
Fulfils the requirements of EN 14181. campaigns

D-JEK
Automated creation of emission declaration in
accordance with German 11th BImSchV
D-CDM
Certified software for greenhouse gas projects
according to UNFCCC methodologies.
Meets the requirements of AM 0021, AM 0028,
AM 0034, AM 0051and ACM 0001.

19
DURAG UK
DURAG France DURAG GmbH
DURAG Inc.

DURAG
India

DURAG GmbH DURAG France S.a.r.l. DURAG data systems


Kollaustraße 105 Parc GIP Charles de Gaulle Kollaustraße 105,
22453 Hamburg, Germany 49, rue Léonard de Vinci, BP 70166 22453 Hamburg, Germany
Tel.+49 (0)40 55 42 18-0 95691 Goussainville CEDEX, France Tel.+49 (0)3731 30 04-0
Fax+49 (0)40 58 41 54 Tel.+33 (0)1 301 811 80 Fax+49 (0)3731 30 04-22
E-Mail: info@durag.de Fax+33 (0)1 393 383 60 E-Mail: info@durag-data.de
E-Mail: info@durag-france.fr

DVN – DURAG Vertrieb/Service Nord DURAG UK Office


Kollaustraße 105 Suite 17, Brookside Business Park DURAG process & systems technology gmbh
22453 Hamburg, Germany Cold Meece, Stone, Staffordshire Kollaustraße 105
Tel.+49 (0)40 55 42 18-0 ST15 0RZ, United Kingdom 22453 Hamburg, Germany
Fax+49 (0)40 58 41 54 Tel.+44 (0)1785 760 007 Tel.+49 (0)40 55 42 18-0
E-Mail: dvn@durag.de Fax+44 (0)1785 760 014 Fax+49 (0)40 58 41 54
E-Mail: durag.uk@durag.de E-Mail: info@durag-process.de

DVO – DURAG Vertrieb/Service Ost DURAG, Inc., USA


Meißner Ring 4 1355 Mendota Heights Road · Suite 200,
09599 Freiberg, Germany Mendota Heights · Hegwein GmbH
Tel.+49 (0)3731 30 04-0 MN 55120, USA Am Boschwerk 7
Fax+49 (0)3731 30 04-22 Tel.+1 651 451-1710 70469 Stuttgart, Germany
E-Mail: durag.freiberg@durag.de Fax+1 651 457-7684 Tel.+49 (0)711 135 788-0
E-Mail: durag@durag.com Fax+49 (0)711 135 788-5
E-Mail: info@hegwein.de
DVS – DURAG Vertrieb/Service Süd DURAG India Instrumentation Ltd
Weidenweg 16 #143/16, Ground Floor, 4th Main Road
73087 Bad Boll, Germany Industrial Town, Rajajinagar
Tel.+49 (0)7164 912 25-0 Bengalooru 560 044, India Smitsvonk Holland B.V.
Fax+49 (0)7164 912 25-50 Tel.+91 (0)80 23 14 56 26 P.O. Box 180, 2700 AD Zoetermeer
E-Mail: info@dvs-badboll.de Fax+91 (0)80 23 14 56 26 Ext. 30 Loodstraat 57, 2718 RV Zoetermeer
E-Mail: info@duragindia.com Netherlands
Tel.+31 (0)79 361 35 33
DVW – DURAG Vertrieb/Service West Fax+31 (0)79 361 13 78
An der Pönt 53a E-mail: sales@smitsvonk.nl
40885 Ratingen, Germany
Tel.+49 (0)2102 74 00-0
Fax+49 (0)2102 74 00 28
E-Mail: dvw@durag.de www.durag.de
VEREWA Umwelt- und Prozessmesstechnik
GmbH
Kollaustraße 105
22453 Hamburg, Germany
Tel.+49 (0)40 55 42 18-0
Fax+49 (0)40 58 41 54
E-Mail: verewa@durag.de
©DURAG GROUP 11/2008 · Subject to change without notice