Вы находитесь на странице: 1из 1

Kelken Construction Systems

550 Hartle Street


Suite C
Sayreville, NJ 08872
(732) 416-6730 FAX (732) 416-6733

US Metric Chart ASTM A615 Grade 60 Rebar


60 KSI Yield 90 KSI Tensile

Rebar Diameter Drill Diameter Embedment Embedment Rebar Yield Rebar Tensile
in. (mm) in. (mm) Depth Develop Depth Develop lb. (kn) lb. (kn)
1.25 x Yield Tensile in.
in. (mm) (mm)
4 5/8 5 6 12000 18000
(13) (15.9) (127) (152) (53.4) (80.1)
5 3/4 6 7 18600 27900
(16) (19.1) (152) (178) (82.7) (124.1)
6 7/8 8 9 26400 39600
(19) (22.2) (203) (229) (117.4) (176.1)
7 1 1/8 9 10 36000 54000
(22) (28.6) (229) (254) (160.1) (240.2)
8 1 1/4 10 12 47400 71100
(25) (31.8) (245) (305) (210.8) (316.3)
9 1 3/8 12 14 60000 90000
(29) (34.9) (305) (356) (266.9) (400.3)
10 1 1/2 14 16 79200 114300
(32) (38.1) (356) (407) (352.3) (508.4)
11 1 5/8 15 17 93600 140400
(36) ( 41.2) (381) (432) (416.3) (624.5)
14 2 20 22 135000 202500
(43) (50.8) (508) (559) (600.5) (900.8)
18 2 1/2 24 26 240000 360000
(57) (63.5) (610) (661) (1067.6) (1601.4)
Steel Strength ASTM A615 Grade 60 Rebar (Plain or Epoxy Coated)
Yield = Fy x Tensile Stress Area
Tensile = Ft x Tensile Stess Area
Shear = .50 x Ultimate Steel Strength

Based on 3500 psi or greater compressive strength concrete 28 days old.

All values based on properly installed Keligrout/Keligrout 101-p per Technical Data Sheets