Tetra Pak Doc. No.

2 897 345-0101

Tetra Pak TPT12


– complete system for precision measurement of temperature
System precision ≤ ± 0.25 °C Fault monitoring with NAMUR NE43 Limits
Compact design All programming via two-wire connection
Operating ambient temperature -30 to +85 °C Connects using M12 connector
Long-term stability down to ± 0.03 °C Digital communication capability is standard

The TPT12 is a complete


system for measuring­.
It has been designed to
provide best possible
­measurement using the
smallest possible size.
The transmitter com-
bined with a Pt100 sensor,
delivers a standardized
4-20 mA signal to PLC or
control system.

Unique performance Dimensions


(typical application)

Operation ambient
temperature:
-20 to +80°C

L=

Process flow:
-20 to +200°C

Typical system precision ± 0.2 °C, in


all combinations of temperatures.
TPT12 GENERAL TECHNICAL DATA

General technical data - transmitter Accuracy and stability


Transducer: For Pt100/RTD-sensors
Sensor: Pt100 Reference conditions: +23 °C ± 5 ºC, 24 V ± 5 V
Ambient temperature: Supply voltage dependence:
Operation -30 to + 85 °C (10-30 V) UDC ≤ 0.003 % FS
Storage -50 to + 85 °C Measurement accuracy: ± 0.02 ºC or 0.01 % of range
N.B. max 80 °C for M12-connector. Measuring range: -200 to +850 ºC
Power consumption: < 0.8 W (30 V/25 mA) Min range: ≥ 10 ºC
Output current: Nominal 4-20 mA Linearity error: ≤ 0.002 ºC
Supply voltage: Min 10 V, max 30 V (UDC) Stability: ≤ 0.03 ºC per year or 0.02 % of measuring
Input resolution: 23 bits range per year at reference conditions
Output resolution: 16 bits
Interference suppression: > 90 dB at 50/60 Hz Internal monitoring - fault indications
Temperature drift: The following faults can be programmed to change the output signal to either
Measuring range ≤ 15 ppm/°C, typical < 5 ppm/°C 3.5 mA or 21.5 mA according to NAMUR NE43:
Drift in reference ≤ 25 ppm/°C, typical < 15 ppm/°C
Zero drift ≤ 0.002 °C/°C (4-wires) or 1. Sensor circuit is open (or abnormally large Pt100-resistance): 21,5 mA
≤ 0.008 °C/°C (2-/3-wires) 2. Sensor temperature falls below (3,5 mA) or exceeds the measuring range
Shifted measuring range: ≤ (zero-value/measuring range) x 0.002 (21,5 mA)
%FS/°C 3. Verification of supply voltage
Temperature drift data above is based on a steady state change of tempera-
tures of the enclosure.
Load resistance: RL≤ (UDC- 9 V)/23 kohms ESD- and EMC-approvals
Normal range: 4 - 20 mA; 20 - 4 mA optional The transmitter conforms to requirements of the EMC directive 2004/108/EC
Range lower limit: ≤ 3.8 mA and later amendments EN 61326-1. (TP KA2791-30)
Range upper limit: ≥ 20.5 mA Deviation: ≤ 0.2% fs.
Alarm limit: The Low Voltage directive 2006/95/EC and later amendments EN 61010-1.
Lower 3.5 mA, (NAMUR NE43)
Upper
Current limit:
21.5 mA (NAMUR NE43)
< 25 mA without processor help
Standard models for TPT12
Start-up time: < 1.5 seconds from powerless state 90510-5632 Temp.meter TPT12 4-20mA 0-150 ° C
Input range: ±1.25 V (24 bits) 90510-5633 Temp.meter TPT12 4-20mA 0-160 ° C
Resolution/bit: < 0.15 μV 90510-5634 Temp.meter TPT12 4-20mA 0-350 ° F
Sensor excitation current: < 0.37 mA
Max allowed serial resistance: 90510-5635 Temp.meter TPT12 4-20mA 0-200 ° C
3 wires 30 ohms/wire 90510-9096 Temp.meter TPT12 4-20mA 0-160 L=25
4 wires 100 ohms/wire
90510-9097 Temp.meter TPT12 4-20mA 0-160 L=15
Sampling rate: approx. 7 samples/sec

Mechanical parts
Sensor material: 1.4404
Sensor material: 1.4547 (SMO) on 90510-9096 and 90510-9097
Connector: M12, material Polyamid
Degree of protection: IP67/IP69K (mating conn. Lumberg PRKT/
PRKWT)

The unique sensor Media pressure


Media pressure max 120 bar. Calculation made by Notified Body
The basis for the TPT12 is the well-proven food product according to prEN13445.
sensor. The sensor mounted in an appropriate sleeve is Installation to media
EHEDG-approved. The risk of bacteria growth is minimal G1/8” to mount into sleeve.
after repeated use and cleaning. Sleeve
Sleeve for welding with selected standard radia,
R: Flat, R = 19 mm or R = 14 mm.
Design
Pt100 sensor element mounted in a conical protective sheath which in turn
can be screwed into a sleeve or into an external thermo well. Sleeve and coni-
cal sheath make a hygienic seal. The seal is EHEDG-approved.
Example of use
Temperature measurements in tubing systems with hygienic demands e. g. in Disposal of product and packing
the food industry. According to national laws or by returning to Pentronic.
Max temperature
Measuring part: 200 °C RoHS
Sensor material Sensors with cable conform to the demands of the RoHS-rules.
1.4404 or 1.4547
Surface finish
Ra ≤ 0.8 is standard. By electro polishing Ra ≤ 0.4 can be offered.
Response time
Subject to change without notice.

Time constant, τ0,90 ≤ 2,5 s in water 0.4 m/s according to IEC 60751.