Вы находитесь на странице: 1из 22

SUMMARY OF PRICES FOR MECHANICAL AND ELECTRICAL SYSTEM

C A D A N G A N M E N G U B A H S U A I D A L A M A N PADA TINGKAT 6 ( S O U ) , Dl D A L A M H O S P I T A L S E D I A ADA ( K A J A N G S P E C I A L I S T H O S P I T A L ) Dl A T A S LOT P T 3 2 7 2 6 , M U K I M K A J A N G , D A E R A H H U L U LANGAT, SELANGOR DARUL EHSAN. S U M M A R Y OF P R I C E S F O R M E C H A N I C A L A N D E L E C T R I C A L S E R V I C E S T h e total tender price for the M e c h a n i c a l and Electrical Services d e s c r i b e d a n d referred to in the drawings and specifications, is made up of the complete supply, delivery, install, testing and c o m m i s s i o n i n g a n d h a n d i n g over in a p p r o v e d working order a n d hereafter p r o v i d e m a i n t e n a n c e during defect liablity p e r i o d . T h e w h o l e of the w o r k s set further in the specification and d r a w i n g s shall b e b a s e d o n fixed lump s u m tender a n d shall include c u s t o m delivery, import taxes, i n s u r a n c e , transportation a n d hoisting o f e q u i p m e n t s . T h e specification a n d drawings shall be read in details before prices are submitted a n d all accidental w o r k s pertaining thereto e v e n t h o u g h not specifically m e n t i o n e d herein or s h o w n in the drawings shall be i n c l u d e d . Tenderers are not allowed to improve conditions contrary to the Specifications and Schedule of Prices

ITEM

DESCRIPTION

AMOUNT (RM)

GRAND SUMMARY

A B C D

PRELIMINARIES MECHANICAL SERVICES ELECTRICAL SERVICES PROVISIONAL S U M (To be used as directed by the P.D. and to be deducted in whole or in part if not used 20,000.00

T O T A L CARRIED TO FORM OF TENDER

TOTAL IN W O R D S : RINGGIT M A L A Y S I A :

SIGNATURE OF TENDERER

STAMP O F T E N D E R E R

DATE

S U M - M_E/1

SCHEDULE OF PRICES

C A D A N G A N M E N G U B A H S U A I D A L A M A N PADA TINGKAT 6 (SDU), Dl D A L A M H O S P I T A L S E D I A A D A ( K A J A N G SPECIALIST H O S P I T A L ) Dl A T A S LOT PT32726, ML)KIM K A J A N G , D A E R A H H U L U L A N G A T , S E L A N G O R

ITEM

DESCRIPTION

QTY

UNIT

RATE (RM)

A M O U N T (RM)

A 1.1

PRELIMINARIES To comply with the general conditions, requirements and preliminaries as specified in this Contract. a) b) c) Mobilisation Insurance, etc. Project supervision, management and liaise with order trade. during defect 1 Lot 1 Lot

1.2

Service and maintenance liability period.

1.3

Shop drawings and two (2) sets of operation and maintenance manuals properly hard cover binded c/w as built drawings and two (2) sets of compact disc (CD) which contain Computer Aided Design (CAD) of the above mentioned items.

Lot

1.4

All necessary submission, liaison and fees payable to authorities until final acceptance of the whole system.

Lot

T O T A L FOR PRELIMINARIES CARRIED TO SUMMARY OF PRICES

PRELIM - 1

MECHANICAL SYSTEM

CADANGAN MENGUBAHSUAI SELANGOR DARUL EHSAN.

D A L A M A N PADA TINGKAT 6 ( S D U ) , Dl D A L A M H O S P I T A L SEDIA

ADA

( K A J A N G S P E C I A L I S T H O S P I T A L ) Dl ATAS LOT PT32726, M U K I M K A J A N G , D A E R A H HULU

LANGAT,

G R A N D S U M M A R Y FOR M E C H A N I C A L W O R K S

ITEM

DESCRIPTION

A M O U N T (RM)

GRAND SUMMARY

A.

AIR C O N D I T I O N I N G AND VENTILATION S Y S T E M

B.

FIRE P R O T E C T I O N SYSTEM

C.

C O L D W A T E R A N D SANITARY PLUMBING S Y S T E M

D.

MEDICAL G A S PIPELINE SYSTEM

T O T A L FOR MECHANICAL W O R K S

SUMMARY - MECHANICAL

C A D A N G A N M E N G U B A H S U A I D A L A M A N PADA TINGKAT 6 (SDU), Dl D A L A M H O S P I T A L S E D I A A D A EHSAN. AIR C O N D I T I O N I N G A N D V E N T I L A T I O N S Y S T E M ITEM DESCRIPTION QTY UNIT RATE (RM) A 1 DEMOLITION WORKS To inspect, dismantle and relocate the existing airconditioning ductworks in approved working order complete with all necessary works, fittings and accessories. 1 Lot

(KAJANG

SPECIALIST H O S P I T A L ) Dl A T A S LOT PT32726, MUKIM KAJANG, D A E R A H H U L U L A N G A T , S E L A N G O R DARUL

AMOUNT (RM)

B 1

NEW INSTALLATION W O R K S G.I supply air ductworks c/w 12mm thick external polyethene (PE) closed cell foam insulation with 33kg/m3 density, splitter dampers, painting works and all other necessary accessories. 1 Lot

Supply air diffuser c/w side entry plenum box with a perforated metal volume control damper in the spigot manually adjustable with diffuser core removed and all other necessary abcessories.

Lot

Return air grilles c/w fixed square pattern core, oppose blade action volume control damper adjustable from front face and all other necessary accessories

Lot

Toilet ventilation fan complete with ductworks, grilles, supports and all necessary accessories.

Set

C 1 2

MISCELLANEOUS Painting and labelling Testing and commissioning 1 1 Lot Lot

TO COLLECTION

BQ-AC-MHB/1

AIR C O N D I T I O N I N G A N D V E N T I L A T I O N SYSTEM ITEM DESCRIPTION QTY UNIT I RATE (RM) COLLECTION 1 Page BQ-AC-MHB/1 AMOUNT (RM)

T O T A L CARRIED TO G R A N D SUMMARY

BQ-AC-MHB/2

CADANGAN MENGUBAHSUAI DALAMAN PADA TINGKAT 6 (SDU), Dl OALAM HOSPITAL SEDIA ADA ( KAJANG SPECIALIST HOSPITAL) Dl AT AS LOT PT32726, MUKIM KAJANG, DAERAH HULU LANGAT, SELANGOR DARUL EHSAN.

FIRE PROTECTION SYSTEM ITEM A DEMOLITION WORKS To inspect, terminate and dismantle the existing sprinkler head at desired location as determined at site in approved working order complete with all necessary works as stated in the specification DESCRIPTION QTY UNIT RATE (RM) AMOUNT (RM)

1 B

Sprinkler range pipe, fittings and orifice plates NEW INSTALLATION WORKS To supply and install new sprinkler head (conceal type) as determined at site in approved working order complete with all necessary works as stated in the specification

Lot

1 2

Sprinkler range pipe, fittings and orifice plates Testing and commissioning

1 1

Lot Lot

TO COLLECTION BQ-f F-MHB/1

FIRE P R O T E C T I O N S Y S T E M ITEM DESCRIPTION QTY UNIT RATE (RM) AMOUNT (RM)

COLLECTION 1 Page BQ-FF-MHB/1

T O T A L CARRIED TO GRAND S U M M A R Y

BQ-FF-MHB/2

C A D A N G A N M E N G U B A H S U A I D A L A M A N PADA T I N G K A T 6 (SOU), Dl D A L A M H O S P I T A L S E D I A A D A (KAJANG SPECIALIST H O S P I T A L ) Dl A T A S LOT PT32726, M U K I M KAJANG, D A E R A H H U L U L A N G A T , S E L A N G O R DARUL EHSAN. C O L D W A T E R A N D S A N I T A R Y P L U M B I N G SERVICES ITEM DESCRIPTION QTY UNIT RATE (RM) 1 INTERNAL COLD WATER SYSTEM General The piping installation specified herein shall be complete and include all valves, mounting brackets, expansion joints and all accessories. Pipe work, valves, fittings and all accessories shall comply with the relevant authority concerned. AMOUNT (RM)

1.1 1

Main and Branch Stacks All internal risers and droppers of ABS 15 pipes tapping from nearest points for the following sizes: a. b. c. 32mm 25mm 20mm 1 1 1 1 Lot Lot Lot Lot

ABS pipe fittings, supports , tees, elbows, valves, stopcocks and all other necessary fittings required for connection to sanitary wares. Pipe penetration through floor slab, complete with larger diameter sleeve and caulking.

Lot

1.2 1

Miscellaneous W o r k s All testing and commissioning including pressure tests, flushing of pipe and all tests required by the Authority and/or Consultant. 1 Lot -\

TO C O L L E C T I O N

BQ-CWSP-MHB/1

C O L D W A T E R A N D S A N I T A R Y P L U M B I N G SERVICES ITEM DESCRIPTION QTY UNIT RATE (RM) II S A N I T A R Y P L U M B I N G SERVICES General The piping installation specified herein shall be complete and include all mounting brackets, expansion joints and all other accessories. Pipe work, fittings and all accessories shall comply with the relevant authority concerned. AMOUNT (RM)

11.1 1 2

All A b o v e G r o u n d uPVC Piping Vent pipe system Flashing and collar to provide water tight connection for 80mm dia. pipe penetration through steel deck roof. 100mm dia. pipe cowl complete with anti-mosquito wire mesh cover at roof (for venting). Soil and waste pipeworks for the following sizes and to be connected to the existing system : a. b. 80mm dia. 32mm dia. 1 1 Lot Lot 1 Lot

III 1

MISCELLANOUS Testing and commissioning 1 Lot

>

TO COLLECTION

...

BQ-CWSP-MHB/2

C O L D W A T E R A N D S A N I T A R Y P L U M B I N G SERVICES ITEM DESCRIPTION QTY UNIT RATE (RM) COLLECTION 1 2 Page No. B Q - C W S P - M H B / 1 Page No. B Q - C W S P - M H B / 2 AMOUNT (RM)

T O T A L C A R R I E D T O G R A N D SUMMARY

BQ-CWSP-MHB/3

CADANGAN MENGUBAHSUAI DALAMAN PADA TINGKAT 6 (SDU), Dl DALAM HOSPITAL SEDIA ADA ( KAJANG SPECIALIST HOSPITAL ) Dl AT AS LOT PT32726, MUKIM KAJANG, DAERAH HULU LANGAT, SELANGOR DARUL EHSAN.

MEDICAL GAS PIPELINE SYSTEM ITEM DESCRIPTION QTY UNIT RATE (RM) A DEMOLITION WORKS To inspect and make good the existing units and pipeworks in approved working order complete with all necessary works and accessories as stated in the specifications 1 Lot AMOUNT (RM)

NEW INSTALLATION WORKS To supply and install new wall terminal units complete with pipeworks and all necessary works and fittings 1.0 OXYGEN SYSTEM a) b) 2.0 a) b) 15mm Copper Pipe Oxygen terminal outlet MEDICAL VACUUM SYSTEM 15mm Copper Pipe Vacuum terminal outlet 1 1 Lot Nos 1 1 Lot Nos

C 1

TESTING AND COMMISSIONING To supply the necessary services, test instrument and the necessary devices to execute the specified works fully in accordance with HTM 2022 practices and as specified herein. 1 Lot

material inspection jointing inspection labelling and marking inspection. sleeving and supports inspection. leakage test. vacuum leakage test. area valve service units A V S U closure and zoning tests. cross-connection test. functional tests of terminal units and NIST connectors. sources of supply tests. pressure safety valves ceritification. verification of drawings. purging and filling. quality test gas identification.

TO COLLECTION BQ-MDG/1

M E D I C A L GAS PIPELINE S Y S T E M ITEM DESCRIPTION QTY UNIT

RATE (RM)

AMOUNT (RM)

COLLECTION 1 BQ-MDG/1

T O T A L M E D I C A L GAS PIPELINE SYSTEM TO C A R R I E D T O M E C H A N I C A L SERVICES SUMMARY

BQ-MDG/2

ELECTRICAL SYSTEM

C A D A N G A N M E N G U B A H S U A I DALAMAN PADA TINGKAT 6 ( S D U ) , Dl D A L A M H O S P I T A L SEDIA A D A (KAJANG S P E C I A L I S T HOSPITAL) Dl ATAS LOT PT32726, M U K I M K A J A N G , D A E R A H H U L U L A N G A T , SELANGOR DARUL E H S A N . G R A N D S U M M A R Y F O R E L E C T R I C A L WORKS

ITEM

DESCRIPTION

A M O U N T (RM)

GRAND SUMMARY

A.

ELECTRICAL A N D TELEPHONE SYSTEM

TOTAL FOR ELECTRICAL W O R K S

SUMMARY - ELECTRICAL

CADANGAN MENGUBAHSUAI DALAMAN PADA TINGKAT 6 (SDU), Dl DALAM HOSPITAL SEDIA ADA (KAJANG SPECIALIST HOSPITAL) Dl ATAS LOT PT32726, MUKIM KAJANG, DAERAH HULU LANGAT, SELANGOR DARUL EHSAN. ELECTRICAL SYSTEM ITEM DESCRIPTION QTY UNIT RATE (RA/I) AMOUNT <RM)

A A.1

DISTRIBUTION BOARDS Supply, delivery, installation, testing and commission the following Distribution Boards c/w MCCBs, MCBs, ELCBs, wiring and other necessary accessories as per drawings and specifications. i) ii) DB-L(N) & L(E) DB-P(N) & P(E) 2 2 Nos Nos

A.2

Testinq and Commissioning Site commissioning tests and factory tests of all sub-switchboards and distribution board inclusive of pressure test, load test, relay calibrations etc. by lisenced tester 1 Lot

B B.1

SUBMAIN CABLING 4x 1C - 16 sq.mm. PVC copper cable c/w 1C x 16 sq. mm green cable in Gl trunking from existing SSB to the following :i) ii) DB- L(N) DB- L(E) 50 50 M M

B.2

4x 1C - 25 sq.mm. PVC copper cable c/w 1C x 16 sq. mm green cable in Gl trunking from existing SSB to the following :i) ii) DB-P(N) DB-P(E) 50 50 1 75mm x 1 M M No Lot

B.3 8.4

Vertical Access Box 2 nos. UPVC 25mm. Junction Box Testinq and Commissioninq All sub-mains cable tests inclusive polarity, nsulation, continuity and pressure tests by isenced tester. Underfloor trunking

B.5 B.6

Nos

Lot

TO COLLECTION

BQ-EL 1/5

ELECTRICAL SYSTEM ITEM DESCRIPTION QTY UNIT RATE (RM) AMOUNT (RM)

C C.1

LIGHTING & SMALL POWER Lighting points using 2 x 1.5 sq. mm. PVC copper cable with earth cable in concealed conduit c/w 10A switch / timer controlled. 13A switch socket outlet points using 2 x 2.5 sq. mm. PVC copper cable c/w earth cable in concealed conduit c/w flush mounted 1 gang 3pin socket. Emergency Lighting & Keluar Sign points using 2 x 1.5 sq. mm. PVC copper cable with earth cable in concealed conduit. Testinq and Commissionina All sub-mains cable tests inclusive polarity, insulation, continuity and pressure tests by lisenced tester. 1 Lot 24 Nos

C.2

33

Nos

C.3

Nos

C.4

0 D.1

LIGHT AND FAN FITTINGS 3 X 36W Recessed fluo. Fitting c/w aluminium parabolic reflector louvres c/w accessories. 2 X 36W Recessed fluo. Fitting c/w aluminium parabolic reflector louvres c/w accessories. 2 X 18W Recessed fluo. Fitting c/w aluminium parabolic reflector louvres c/w accessories. Complete set of recessed mounted 1 x 8W Emergency Light fitting c/w sealed nickel cadmium battery (3-hour) Keluar Sign 2 x 15W cadmium battery (3-hour) Testing & Commisioning c/w sealed nickel 4 Nos

D.2

Nos

D.3

11

Nos

D.4

Nos

>

D.5

No

D.6

Lot

TO COLLECTION

BQ-EL 2/5

ELECTRICAL SYSTEM ITEM DESCRIPTION QTY UNIT RATE (RM) AMOUNT (RM)

E E.1

TELEPHONE DP BOX 10-pair incoming / 10-pair outgoing DP box similar to KRONE type c/w lightning arrestor and earthing to Telekom's requirement. TELEPHONE TRUNKING & WIRING 1 6 Lot Nos 1 No

E.2

E.2.1 All necessary M.S. telephone trunking. E.2.2 Telephone wiring point using 3-wire/ 0.63 PVC cable in 25mm. dia. concealed uPVC conduit from DP to individual telephone point and other related wiring c/w flush mounted telephone outlet etc. E.2.3 All necessary multicore telephone cable laid on trunking /cable tray. E.2.4 Complete earthing installation. system for the above

Lot

Lot

F F.1

IT N e t w o r k i n q Services IT Networking floor Distribution Panel c/w Fibre Distribution unit, switches, patch panel, equipment rack, cabling and accessories. All necessary M.S. telephone trunking vertical and horizontal run in concealed as per drawings and specifications. (Sharing with telephone trunking are not countable). All necessary underfloor uPVC (heavy duty) telephone trunking including alowance of chases of floor slab. (Sharing with telephone trunking are not countable). Data wiring point using CAT 6, A pairs UTP cable in Concealed uPVC conduit from Hub centre individual Data point and other related wiring c/w flush mounted data outlet etc. System cabling works for Data IT infrastructure from the server to the IT distribution panel using 12 core fiber optic multimode cable run in telephone ducting/ telephone riser c/w lightning protection system. Testing & Commisioning 1 No

F.2

Lot

F.3

Lot

F.4

Nos

F.5

Lot

F.6

Lot

TO COLLECTION

BQ-EL 3/5

ELECTRICAL SYSTEM ITEM DESCRIPTION QTY UNIT RATE (RM) AMOUNT (RM)

G G.1

MATV Services Matv point c/w cabling from existing splitter 1 Lot

H H.1 H.2 H.3 H.4 H.5 H.6 H.7

DIGITAL CALL SYSTEM DG devise Gateway Thermal ticket printer LCD Main Display size 20" diagonal. Counter keypad terminal with LCD display. Voice module with 2 speakers PS 16 power hub Installation, termination including all necessary accessories. System cabling run in high impact UPVC conduit/ epoxy coated mild steel trunking. Testing and commissioning
1

No No Nos Nos

Nos Nos Lot

H.8

Lot

H.9

Lot

>

TO COLLECTION

8Q-EL 4/5

ELECTRICAL SYSTEM ITEM DESCRIPTION QTY UNIT RATE (RM) AMOUNT (RM)

COLLECTION 1 2 3 4 Page BQ-EL 1/5 Page BQ-EL 2/5 Page BQ-EL 3/5 Page BQ-EL 4/5

TOTAL

BQ-EL 5/5

Вам также может понравиться