Вы находитесь на странице: 1из 75

Product Catalog

Instructions For Use:


OSSEOTITE, OSSEOTITE XP, Certain, PREVAIL, Encode, IOL, Miniplant, GingiHue, Gold-Tite, Provide, STA, ZiReal, CAM StructSURE, NanoTite, PreFormance, QuickBridge This document applies to dental implants, abutments, overdenture bars and associated surgical, restorative and dental laboratory components. For detailed information on the specific procedure for the product you are using, please refer to the individual product labels and/or the appropriate manual: Product Catalog - CATALOG: Listing of all products Surgical Manual - CATSM: Dental implant placement, surgical protocol and cover screw insertion Restorative Manual - CATRM: Abutment placement, provisional and final restoration protocols Additional Restorative Manuals: DIEM Guidelines - ART860 CAM StructSURE Manual - ART868 Encode Restorative Manual - ART924 QuickBridge Manual - ART1016 Description: BIOMET 3i Dental Implants are manufactured from biocompatible titanium and titanium alloy and abutments from titanium, titanium alloy, gold alloy and ceramic material. BIOMET 3i Dental Implants and Abutments include various surface treatments and coatings. Other restorative components are manufactured with titanium, titanium alloy, gold alloy, stainless steel and a variety of polymers. For specific product description and net quantity refer to individual product labels. Indications for Use: BIOMET 3i Dental Implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth utilizing delayed or immediate loading, or as a terminal or intermediary abutment for fixed or removable bridgework and to retain overdentures. BIOMET 3i OSSEOTITE and NanoTite Dental Implants are intended for immediate function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function. Additional Indications: BIOMET 3i Dental Abutments and Overdenture Bars are intended for use as an accessory to endosseous dental implants to support a prosthetic device in a partially or edentulous patient. These are intended for use to support single and multiple tooth prostheses, in the mandible or maxilla. The prostheses can be screw or cement-retained to the abutment. PEEK Abutment Posts and Temporary Cylinders are intended for use as an accessory to endosseous dental implants to support a prosthetic device in a partially or fully edentulous patient. These are intended for use to support single and multiple unit prostheses in the mandible or maxilla for up to 180 days during endosseous and gingival healing and are for nonocclusal loading of single and multiple unit provisional restorations. The prostheses can be screw and/or cement-retained to the abutment. These Temporary Posts and Cylinders require a minimum interarch space of 6mm and a maximum angulation of 15. These also allow for occlusal loading of single and multiple unit restorations of integrated implants for guided soft tissue healing. The QuickBridge Provisional Components are intended to be mated with BIOMET 3i Conical Abutments for use as an accessory to endosseous dental implants to support a prosthetic device in a partially or fully edentulous patient. The QuickBridge Provisional Components are intended to support multiple unit prostheses in the mandible or maxilla for up to 180 days during endosseous and gingival healing. Contraindication: Placement of dental implants may be precluded by patient conditions that are contraindications for surgery. BIOMET 3i Dental Implants should not be placed in patients where the remaining jaw bone is too diminished to provide adequate implant stability. Storage and Handling: Devices should be stored at room temperature. Refer to individual product labels and the Surgical Manual for special storage or handling conditions. Warnings: Excessive bone loss or breakage of a dental implant or restorative device may occur when an implant or abutment is loaded beyond its functional capability. Physiological and anatomic conditions may negatively affect the performance of dental implants. The following should be taken into consideration when placing dental implants: Poor bone quality Poor oral hygiene Medical conditions such as blood disorders or uncontrolled hormonal conditions It is recommended that small diameter implants not be restored with angled abutments in the molar region. Mishandling of small components inside the patients mouth carries a risk of aspiration and/or swallowing. Forcing the implant into the osteotomy deeper than the depth established by the drills can result in: stripping the driver hex interface inside the implant, stripping the driver, cold-welding of the mount-driver interface to the implant or stripping the walls of the osteotomy that may prevent an effective initial implant fixation. Clinical data have demonstrated enhanced performance of OSSEOTITE Implants as compared to other BIOMET 3i Dental Implants in patients with poor quality bone. Precautions: For safe and effective use of BIOMET 3i Dental Implants, abutments and other surgical and restorative dental accessories, these products or devices should only be used by trained professionals. The surgical and restorative techniques required to properly utilize these devices are highly specialized and complex procedures. Improper technique can lead to implant failure, loss of supporting bone, restoration fracture, screw loosening and aspiration. Sterility: All dental implants and some abutments are supplied sterile and are sterilized by an appropriate validated method. Refer to individual product labels for sterilization information; all sterile products are labeled STERILE. All products sold sterile are for single use before the expiration date printed on the product label. Do not use sterile products if the packaging has been damaged or previously opened. Do not re-sterilize or autoclave except where instructions to do so are provided on the product label, in the Surgical Manual, in the Restorative Manual or in any additional marketing literature for that product. Products provided nonsterile must be cleaned and sterilized according to the directions found in ART630 or the Surgical Manual prior to use. Procedural Precautions, Surgery: For a detailed explanation of the procedural precautions refer to the Surgical Manual. During the planning phase, it is important to determine the vertical dimension, the actual space available between the alveolar crest and the opposing dentition, in order to confirm that the available space will accommodate the proposed abutment and the final crown restoration. This information varies with each patient and abutment; therefore it should be carefully evaluated before placing any dental implant. The final prosthesis should be designed prior to the placement of the dental implant. Utilize continuous irrigation with a cool, sterile irrigating solution to avoid excessive damage to the surrounding tissue and to prevent compromising osseointegration. This is mandatory during all procedures. Avoid excessive pressure during preparation of the bone site. As the drilling speed varies based on the instrument and the surgical procedure, recommendations for speed can be found in the Surgical Manual. Only sharp instruments of the highest quality should be used for any surgical procedure involving bone. Minimizing trauma to the bone and surrounding tissue enhances the potential for successful osseointegration. In order to eliminate contaminants and other sources of infection, all non-sterile devices should be cleaned and/or sterilized prior to use, per the instructions on the individual product labels. Procedural Precautions, Restoration: The healing period varies depending on the quality of the bone at the implantation site, the tissue response to the implanted device and the surgeons evaluation of the patients bone density at the time of the surgical procedure. Excessive force applied to the dental implant should be avoided during the healing period. Proper occlusion should be evaluated on the implant restoration to avoid excessive force. Potential Adverse Events: Potential adverse events associated with the use of dental implants may include: Failure to integrate Loss of integration Dehiscence requiring bone grafting Perforation of the maxillary sinus, inferior border, lingual plate, labial plate, inferior alveolar canal, gingiva Infection as reported by: abscess, fistula, suppuration, inflammation, radiolucency Persistent pain, numbness, paresthesia Hyperplasia Excessive bone loss requiring intervention Implant breakage or fracture Systemic infection Nerve injury

Caution: U.S. Federal Law restricts this device to sale by or on the order of a licensed dentist or physician.

Table Of Contents
Introduction
Company Overview Product Innovations Timeline System Distinctions Patient Specific Restorations Overview i ii iii v

External Hex Connection:


Cement-Retained Restorations GingiHue Posts ZiReal Posts UCLA Abutments Screw-Retained Restorations UCLA Abutments 31 33 35 IOL Abutments Conical Abutments 1 OverdentSURE Restorations 1 2 DIEM IOL Abutments Standard Abutments LOCATOR Abutments O-Ring Abutments Dal-Ro Abutments Provisional Restorations PreFormance Posts 3 5 7 9 PreFormance Temporary Cylinders 47 48 37 39 41 43 45 25 27 29

Restorative Products Flowchart


Cement-Retained Restoration Details Screw-Retained Restoration Details Provide Abutment Selection Guide

Restorative Products
Certain Internal Connection:
Cement-Retained Restorations Provide Abutments GingiHue Posts ZiReal Posts UCLA Abutments Screw-Retained Restorations UCLA Abutments IOL Abutments Conical Abutments OverdentSURE Restorations DIEM IOL Abutments Standard Abutments LOCATOR Abutments Provisional Restorations PreFormance Posts PreFormance Temporary Cylinders

Miscellaneous Restorative Products


Screws Mechanical Driver Kits Drivers And Driver Tips 49 51 52 53 54 55

11 13 15

Navigator System Instrumentation Overview Navigator Laboratory Kit Laboratory Tools/Miscellaneous Items

17 19 21

Professional Development Products


Tools For The Art Of Business Building 56

Additional Information
Index 23 24 Ordering Form Ordering Information 57

Introduction
Company Overview
Better For Your Patients. Better For Your Practice.
Implant Innovations Inc. (3i) was co-founded in 1987 by a periodontist and an engineer. The clinician believed his patients deserved better fitting and looking implant restorations than could be accomplished with available implant systems. In 1999, BIOMET, Inc., a leading manufacturer of orthopedic components, acquired 3i. Today, BIOMET 3i offers one of implant dentistrys most comprehensive lines of implants and abutments, augmented by a growing line of site preparation and regenerative products. BIOMET 3i pioneered the development of biologically driven implants, winning worldwide acclaim for the microtextured surface and superior clinical success rates of the OSSEOTITE Implant. Headquartered in Palm Beach Gardens, Florida, with operations throughout the world, BIOMET 3i is one of the leading companies in the oral reconstruction market. Of equal importance, BIOMET 3i brings the same innovation, high standards and comprehensive approach to customer service, practice and laboratory support and education. The BIOMET 3i Value Proposition: Quality-Driven Design And Manufacturing Practical Product Innovation Commitment To Evidence-Based Research Exceptional Customer Service Capabilities Comprehensive Professional Education Partnership Approach To Practice Growth

Mission Statement:
BIOMET 3i will be recognized as a global leader in the oral reconstruction marketplace. We will achieve this through superior customer support and continuous product innovation.

In order to have greater consistency in the use of the 3i Brand, increase global awareness and recognition of the parent company and leverage the synergy of consistent imaging among all BIOMET Subsidiaries, 3i Products began selling under the BIOMET 3i Name worldwide in 2007. This has greatly enhanced BIOMET 3is Research and Development resources and potential for growth.

Product Innovations Timeline


1987 To Present
1987
2mm Standard Abutments One-Piece Abutment Posts

1988
Machined Gold UCLA Abutments Modification Abutments 2.9mm Miniplants Pre-Angled Abutments

1989
Tapered Abutments 3.75mm Threaded Implants

1990
EP Healing Abutments

1991
Wide Diameter Implants

1995
ASYST Abutment Delivery System Twist Lock Impression Copings ICE Implants

1999
GingiHue Posts 15 Pre-Angled GingiHue Posts Prep-Tite Caps Try-In Screw With One Turn OSSEOTITE XP Implants Restorative Torque Indicator

2003
OSSEOTITE Certain Internal Connection Implant System With The QuickSeat Connection OverdentSURE Approach

2007
NanoTite Implants Conical Angled Abutments QuickBridge Provisional Components OsseoGuard Membrane

1992
Conical Abutments For Single-Unit Applications

1996
OSSEOTITE Implants Gold Standard ZR Hex Machining

2000
ZiReal Posts Simple Logic PCCS Platelet Concentrate Collection System

2004
DIEM Immediate Occlusal Loading Guidelines & IOL Components ARCHITECH PSR: CAM StructSURE Precision Milled Bars, Encode Restorative System

2008
Navigator System For CT Guided Surgery NanoTite Tapered PREVAIL Implants Encode Complete RegenerOss Family Of Products

1993
Protocol For Single-Stage Surgery With Hex Top Implants Two-Piece EP Healing Abutments Two-Piece Abutment Posts

1997
TG OSSEOTITE Single-Stage Implants

2001
OSSIX Membrane

2005
3i IDS Learning Library PREVAIL Implants Provide Abutments

2009
Low Torque Indicating Ratchet Wrench

1994
Emergence Profile System EP Abutment Posts STA Abutments

1998
Prep-Tite Posts Gold-Tite Screws Biogran Bone Graft Material

2002
LOCATOR Abutments Safescraper Bone Collector Tapered Implant System Calcigen Oral Bone Graft Stabilizer

2006
Advanced Cutting Technology (ACT) Twist Drills OSSEOCISION Drilling Unit PreFormance Provisional Components

2010
Larger Particle Size Endobon Xenograft Granules


ii

Introduction
System Distinctions
Certain Internal Connection Implants
The internal connection implant design is for ease of use and simplicity. Material: Titanium Alloy QuickSeat Connection: It Clicks! The Certain Implant System features the QuickSeat Connection, which has an audible and tactile click when placing impression copings and abutments. This click feedback provides confirmation and confidence to a clinician that the components are properly seated. When It Clicks, Its Seated. Youre Certain.

Abutment fingers cause the click and also provide retention for the prosthetic components in the implant when restorations are being tried in or placed before the screw is placed.

The 6/12 internal connection has both a hex and a 12-point double hex. The hex has two functions: engaging the driver tip for mountless delivery during implant placement and providing anti-rotation for all straight abutments. The 12-point double hex provides rotational positioning every 30 for pre-angled abutments.

Impression Copings: Pick-Up and Twist Lock Transfer Copings are available in the internal connection design. The impression copings also click when properly seated. The copings have a different finger design that engages 2mm internally in the implant, as compared to the abutments design that engages 4mm deep in the implant. This shorter engagement in the implant is important because it allows off-axis draw for impressions of divergent implants.

iii

System Distinctions

External Hex Connection Implants


The external hexed implant design is widely used offering versatility and restorative flexibility. Material: Commercially Pure Titanium (OSSEOTITE Implants) Titanium Alloy (NanoTite Implants) Gold Standard ZR (Zero Rotation) is a patented design of machined microstops within the corners of the hex in the abutment. The design reduces horizontal rotation between the implant and abutment. Gold Standard ZR is available on UCLA, GingiHue Post and Conical Abutments.

The 12-point double hex, which is machined in the 15 Pre-Angled GingiHue Post, provides rotational positioning in 30 increments on the implant hex.

Impression Copings: Pick-Up and Twist Lock Transfer Copings are both available in the external hex design and three EP (Emergence Profile) Diameters. The patented Twist Lock Design provides a more accurate transfer of the implant hex compared to other transfer (closed tray) techniques. The unique Twist Lock Feature provides a series of undercuts to guide the coping into the impression for stability. As a result, the copings lock into orientation grooves upon clockwise rotation, thereby allowing a tactile sensation of resistance that ensures an accurate hex transfer. Precise Abutment Placement: The Asyst Abutment Placement Tool provides fingertip control for fast and easy abutment delivery. The patented packaging design makes abutment placement easier because the abutment is delivered sterile from the package directly to the implant site. The system includes the abutment, abutment screw and plastic seating device. The plastic seating device facilitates precise placement of the abutment on the implant, thus reducing chair time. The Asyst Tool is packaged with the Standard and Conical Abutments.

iv

Introduction
Patient Specific Restorations Overview

ARCHITECH PSR
P ATIENT SPECIFIC RESTORATIONS

Encode Impression System


The Encode Impression System eliminates the need for an implant-level impression while delivering a Patient Specific Restoration that has the appropriate margin height and natural emergence contours for the patient. This accuracy is achieved from an impression of the Encode Healing Abutment. Codes embedded on the occlusal surface of the Encode Healing Abutment communicate the collar height, implant hex-orientation, platform diameter and interface (the Certain Internal Connection or External Hex Connection) of the implant. Because the tissue is healed at the time of impression, the margin is designed to have the appropriate placement and contour. The result is a patient specific, anatomically designed, final Encode Abutment. Available in titanium, titanium nitride coating and zirconia.

CAM StructSURE Precision Milled Bars And Frameworks


CAM StructSURE Precision Milled Bars are created with the technology to achieve a truly passive fit. These are available in Hader and Dolder Designs for overdenture bars, primary bars and in fixed hybrid designs. This technology does not require any wax or resin design from the technician. The bars can be made on most major dental implants and abutments. Because these are milled from one solid piece of lightweight titanium, the potential for weakness caused by soldering or laser welded joints is eliminated. You receive a completed superstructure ready for prosthesis processing. No polishing or retention creation necessary. BIOMET 3i can even tap holes for attachments. Copy Milled Bars are also available for those who prefer to design a bar or framework in resin pattern to the patients specifications. Note: Please ensure that as many implants as necessary are used for a fully stable restoration.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Introduction
Patient Specific Restorations Overview

Available CAM StructSURE Precision Milled Bar Designs


Hybrid Design #1 Hybrid Design #2 Wrap Around Bar Canada Bar

Fixed prosthesis Metal lingual Low buccal finish line

Fixed prosthesis Designed for easy hygiene Metal lingual Buccal and lingual finish lines

Fixed prosthesis Acrylic resin wraps around the bar

Fixed hybrid bar Removable prosthesis engages bar

Dolder Eggshape

Dolder U Shape

Hader Bar

Removable overdenture design Clips allow for anterior/posterior rotation of the denture

Removable overdenture design with clips for more rigid fit Clips allow for anterior/posterior rotation of the denture Provides lateral stability to denture

Removable overdenture design with clips that engage undercuts Provides some lateral stability 4mm between implants is needed for clips

Primary Bar

Combination Primary With Hader Or Dolder

Copy Milled

Most secure removable overdenture design May be used with attachments or secondary casting Bar can be designed with a 2 6 taper

Combines a milled bar with Hader or Dolder Designs Excellent lateral stability Bar can be designed with a 2 6 taper

Fixed or removable bar prosthesis Framework for fixed prosthesis Technician fabricated resin pattern for porcelain or acrylic bonded to titanium Must fall within existing design parameters

vi

Restorative Products Flow Chart


Cement-Retained Restoration Details
Is The Implant Angled?
No
GingiHue UCLA ZiReal Encode Provide

(Greater than 15 Divergence)

Yes
UCLA 15 Pre-Angled GingiHue Encode
Interarch Space

Interarch Space

Less than 7mm UCLA Encode Provide


Tissue Height

7mm or more GingiHue ZiReal UCLA Encode Provide


Tissue Height

Less than 7mm UCLA Encode

7mm or more UCLA 15 Pre-Angled GingiHue Encode

Less than 2mm UCLA Provide Encode

Less than 2mm UCLA Provide Encode

2mm or more GingiHue UCLA Encode ZiReal Provide

Tissue Height

Less than 2mm UCLA Encode

2mm or more UCLA 15 Pre-Angled GingiHue Encode

Is the implant centered in the tooth site? If the answer is no, UCLA is the best option.

Screw-Retained Restoration Details


Is The Implant Angled?
No
UCLA Conical IOL
Interarch Space

(Greater than 15 Divergence)

Yes
17 Angled Conical 25 Angled Conical
Interarch Space

Less than 5mm UCLA IOL


Tissue Height

5mm or more UCLA Conical


Tissue Height

Less than 9.5mm UCLA IOL

9.5mm or more 17 Angled Conical 25 Angled Conical

Tissue Height

Less than 2mm UCLA

2mm or more UCLA IOL

Less than 2mm UCLA

2mm or more UCLA Conical

Less than 2mm UCLA

2mm or more 17 Angled Conical 25 Angled Conical

Is the implant centered in the tooth site? If the answer is no, UCLA is the best option.

Provide Abutment Selection Guide


Blue
a = 4.1mm c = 4mm d = 4.8mm

Blue
a = 4.1mm c = 5.5mm d = 4.8mm

Yellow
a = 5mm c = 4mm d = 6.5mm

Green
a = 6mm c = 4mm d = 6.5mm

Yellow
a = 5mm c = 5.5mm d = 6.5mm

Green
a = 6mm c = 5.5mm d = 6.5mm

Abutments

IPA4140 IPA4240 IPA4340 IPA4440

IPA4155 IPA4255 IPA4355 IPA4455

IPA5140 IPA5240 IPA5340 IPA5440

IPA6140 IPA6240 IPA6340 IPA6440

IPA5155 IPA5255 IPA5355 IPA5455

IPA6155 IPA6255 IPA6355 IPA6455

Screws

IUNIHG

IUNIHG

IUNIHG

IUNIHG

Protection Caps

PPC484

PPC485

PPC654

PPC655

Impression Copings

PIC484
Non-Prepared

PIC485
Non-Prepared

PIC654
Non-Prepared

PIC655
Non-Prepared

PIC484H
Prepared

PIC485H
Prepared

PIC654H
Prepared

PIC655H
Prepared

PAA484

PAA485
Non-Prepared

PAA654
Non-Prepared

PAA655
Non-Prepared

Laboratory Analogs

Non-Prepared

PAAP48
Prepared

PAAP48
Prepared

PAAP65
Prepared

PAAP65
Prepared

Waxing Sleeves

PWS48S
Single Unit

PWS48S
Single Unit

PWS65S
Single Unit

PWS65S
Single Unit

PWS48M
Multi-Unit

PWS48M
Multi-Unit

PWS65M
Multi-Unit

PWS65M
Multi-Unit

Temporary Cylinders

PUA48S
Single Unit

PUA48S
Single Unit

PUA65S
Single Unit

PUA65S
Single Unit

PUA48M
Multi-Unit

PUA48M
Multi-Unit

PUA65M
Multi-Unit

PUA65M
Multi-Unit

* b: collar height selection depends on tissue depth

Restorative Products
Cement-Retained Restorations / Certain Internal Connection

Provide Abutments
Indications: Material:

Single and multi-unit porcelain fused to metal restorations Fixed margin abutments Snap-on impression components
4.1mm

Maximum angulation correction of 10 Minimum interarch space of 7mm

Titanium Alloy

Seating Surface
Collar Height Post Height Abutment Placement Kit Item Numbers Abutment Restorative Kit Abutment Only

Emergence Profile

4.8mm 4.8mm 4.8mm 4.8mm 4.8mm 4.8mm 4.8mm 4.8mm


5.0mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm 1.0mm 2.0mm 3.0mm 4.0mm


Collar Height

4.0mm 4.0mm 4.0mm 4.0mm 5.5mm 5.5mm 5.5mm 5.5mm


Post Height

PAK4140* PAK4240* PAK4340* PAK4440* PAK4155* PAK4255* PAK4355* PAK4455*

PRK484** PRK484** PRK484** PRK484** PRK485** PRK485** PRK485** PRK485**


Item Numbers

IPA4140 IPA4240 IPA4340 IPA4440 IPA4155 IPA4255 IPA4355 IPA4455


profile post collar

Seating Surface
Abutment Placement Kit Abutment Restorative Kit Abutment Only

6.5mm 6.5mm 6.5mm 6.5mm 6.5mm 6.5mm 6.5mm 6.5mm


6.0mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm 1.0mm 2.0mm 3.0mm 4.0mm


Collar Height

4.0mm 4.0mm 4.0mm 4.0mm 5.5mm 5.5mm 5.5mm 5.5mm


Post Height

PAK5140* PAK5240* PAK5340* PAK5440* PAK5155* PAK5255* PAK5355* PAK5455*

PRK654** PRK654** PRK654** PRK654** PRK655** PRK655** PRK655** PRK655**


Item Numbers

IPA5140 IPA5240
post

IPA5340
collar

IPA5440 IPA5155 IPA5255 IPA5355 IPA5455


profile

Seating Surface
Abutment Placement Kit Abutment Restorative Kit Abutment Only

6.5mm 6.5mm 6.5mm 6.5mm 6.5mm 6.5mm 6.5mm 6.5mm

1.0mm 2.0mm 3.0mm 4.0mm 1.0mm 2.0mm 3.0mm 4.0mm

4.0mm 4.0mm 4.0mm 4.0mm 5.5mm 5.5mm 5.5mm 5.5mm

PAK6140* PAK6240* PAK6340* PAK6440* PAK6155* PAK6255* PAK6355* PAK6455*

PRK654** PRK654** PRK654** PRK654** PRK655** PRK655** PRK655** PRK655**

IPA6140 IPA6240 IPA6340 IPA6440 IPA6155 IPA6255 IPA6355 IPA6455


profile post collar

*Abutment Placement Kit includes the Provide Abutment, Protection Cap and Certain Gold-Tite Hexed Screw IUNIHG. **Abutment Restorative Kit includes Impression Coping, Impression Coping w/Holes, Waxing Sleeve (single-unit), Waxing Sleeve (multi-unit) and Non-Prepared Analog. 3

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Cement-Retained Restorations / Certain Internal Connection

Provide Components

Description
Emergence Profile 4.8

4.0mm Post Height


6.5

5.5mm Post Height


4.8 6.5

Protection Cap Impression Coping (Unprepared) Impression Coping W/Holes (Prepared) Abutment Analog (Unprepared) Abutment Analog W/Pin (Prepared) Abutment Screw Waxing Sleeve Temporary Cylinder
*Recommended

PPC484 PIC484 PIC484H PAA484 PAAP48

PPC654 PIC654 PIC654H PAA654 PAAP65

PPC485 PIC485 PIC485H PAA485 PAAP48 IUNIHG*, IUNIHT

PPC655 PIC655 PIC655H PAA655 PAAP65

single-unit multi-unit single-unit multi-unit

PWS48S PWS48M PUA48S PUA48M

PWS65S PWS65M PUA65S PUA65M

PWS48S PWS48M PUA48S PUA48M

PWS65S PWS65M PUA65S PUA65M

Included With Each Placement Kit:

Included With Each Restorative Kit:

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Certain Internal Connection

Protection Cap

Analog Abutment And Analog Abutment W/Pin

Waxing Sleeve

Impression Coping And Impression Coping W/Holes

Temporary Cylinder

Restorative Products
Cement-Retained Restorations / Certain Internal Connection

GingiHue Posts
Indications: Material:

Single and multi-unit porcelain fused to metal restorations Areas of thin tissue where gingival discoloration is possible Preparable to follow gingival contours Conventional crown and bridge procedures Maximum angulation correction of 15 Minimum interarch space of 6mm
7.0

Titanium Alloy

7.0

Prep-Tite Cap For Straight GingiHue Posts


h

profile

profile

3.4mm

Seating Surface
Collar Height Item Numbers (Straight) Item Numbers (15 Pre-Angled) Height Item Numbers

Emergence Profile

3.8mm 3.8mm
4.1mm
Emergence Profile

2.0mm 4.0mm
Collar Height

IMAP32G IMAP34G
Item Numbers (Straight)

IMPAP32G IMPAP34G
Item Numbers (15 Pre-Angled)

5mm 5mm
Height

PTC345 PTC345
Item Numbers

Seating Surface

5.0mm 5.0mm 6.0mm 6.0mm 7.5mm 7.5mm


5.0mm
Emergence Profile

2.0mm 4.0mm 2.0mm 4.0mm 2.0mm 4.0mm


Collar Height

IAPP452G IAPP454G IAPP462G IAPP464G IAPP472G IAPP474G


Item Numbers (Straight)

IPAP452G IPAP454G IPAP462G IPAP464G IPAP472G IPAP474G


Item Numbers (15 Pre-Angled)

5mm 5mm 5mm 5mm 5mm 5mm


Height

PTC455 PTC455 PTC465 PTC465 PTC475 PTC475


Item Numbers

Seating Surface

5.0mm 5.0mm 6.0mm 6.0mm 7.5mm 7.5mm


6.0mm
Emergence Profile

2.0mm 4.0mm 2.0mm 4.0mm 2.0mm 4.0mm


Collar Height

IWPP552G IWPP554G IWPP562G IWPP564G IWPP572G IWPP574G


Item Numbers (Straight)

IPAP552G IPAP554G IPAP562G IPAP564G IPAP572G IPAP574G


Item Numbers (15 Pre-Angled)

5mm 5mm 5mm 5mm 5mm 5mm


Height

PTC555 PTC555 PTC465 PTC465 PTC475 PTC475


Item Numbers

Seating Surface

6.0mm 6.0mm 7.5mm 7.5mm

2.0mm 4.0mm 2.0mm 4.0mm

IWPP662G IWPP664G IWPP672G IWPP674G

IPAP662G IPAP664G IPAP672G IPAP674G

5mm 5mm 5mm 5mm

PTC665 PTC665 PTC475 PTC475

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Cement-Retained Restorations / Certain Internal Connection

GingiHue Post Components


Laboratory Analog PreFormance Post Abutment Screw

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile

3.4mm
3.4 3.8 4.1

4.1mm
5.0 6.0 7.5 5.0 5.6

5.0mm
6.0 7.5 6.0

6.0mm
6.8 7.5

Pick-Up Impression Coping

IMIC30 IMIC33 IIIC41,IIIC42* IIIC12 IIIC60 IIIC75 IWIP50 IWIP55 IWIP56 IWIP57 IWIP60 IWIP66 IWIP67 N/A IIIC44 IIIC45 IIIC46 IIIC47 IWIT50 IWIT55 IWIT56 IWIT57 IWIT60 IWIT66 IWIT67 IILA20 IILA20 IILA20 IILAW5 IILAW5 IILAW5 IILAW5 IILAW6 IILAW6 IILAW6

Twist Lock Impression Coping N/A Laboratory Analog Laboratory Abutment Holder Abutment Screw Hex Try-In Screw (5-pack) QuickSeat Activator Tool PreFormance Post
*Non-Hexed **Recommended

IMMILA IMMILA IILA20

ILTAH57 IUNIHG**, IUNIHT IUNITS IQSA01 See page 23

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Certain Internal Connection

Pick-Up Impression Coping

Twist Lock Impression Coping

Laboratory Abutment Holder

QuickSeat Activator Tool

Restorative Products
Cement-Retained Restorations / Certain Internal Connection

ZiReal Posts
Indications: Material:

Single and multi-unit all ceramic restorations Preparable to follow gingival contours Minimum interarch space of 6mm Aesthetic restorations when tissue is limited Maximum angulation of 10
4.1mm

Zirconia Ceramic With A Titanium Alloy Interface

Seating Surface
Collar Height Item Numbers

Emergence Profile

5.0mm 6.0mm
5.0mm
Emergence Profile

4.0mm 4.0mm
Collar Height

ICAP454* ICAP464*

7.0

Seating Surface
Item Numbers

6.0mm 7.5mm

4.0mm 4.0mm

IWCAP564*
profile

IWCAP574*

*Includes Certain ZiReal Gold-Tite Screw (IZSHG) and ZiReal Try-In Screw (IZIRTS).

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
Cement-Retained Restorations / Certain Internal Connection

ZiReal Post Components


Laboratory Analog PreFormance Post Abutment Screw

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile 4.1 5.0

4.1mm
6.0 7.5 5.0 5.6

5.0mm
6.0 7.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Laboratory Abutment Holder Abutment Screw (included) Hex Try-In Screw (included) QuickSeat Activator Tool PreFormance Post
*Non-Hexed

IIIC41,IIIC42* IIIC12 IIIC44 IILA20 IIIC45 IILA20

IIIC60 IIIC46 IILA20

IIIC75 IIIC47 IILA20 ILTAH57 IZSHG IZIRTS IQSA01

IWIP50 IWIT50 IILAW5

IWIP55 IWIT55 IILAW5

IWIP56 IWIT56 IILAW5

IWIP57 IWIT57 IILAW5

See page 23

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Certain Internal Connection

Pick-Up Impression Coping

Twist Lock Impression Coping

Laboratory Abutment Holder

QuickSeat Activator Tool

Restorative Products
Cement-Retained Restorations / Certain Internal Connection
UCLA Abutments
Indications: Material:

Laboratory fabricated custom abutments Single and multi-unit restorations Minimum interarch space of 6mm For aesthetic restorations when tissue is limited Maximum angulation correction of 30

Machined Gold Alloy Cylinder With Plastic Unitube

Description

Item Numbers

3.4mm 4.1mm

Seating Surface

Gold (Hexed)
Seating Surface

IMUCG1C IGUCA1C N/A N/A N/A


Hexed
4.0 11

Gold (Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Hexed) 25PK
5.0mm

Seating Surface

Gold (Hexed) Gold Standard ZR (Hexed) Castable (Hexed)


6.0mm

IWGA51C N/A N/A IWGA61C N/A N/A

Seating Surface

Gold (Hexed) Gold Standard ZR (Hexed) Castable (Hexed)

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Cement-Retained Restorations / Certain Internal Connection


UCLA Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog PreFormance Post Laboratory Abutment Holder Abutment Screw QuickSeat Activator Tool

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile

3.4mm
3.4 3.8 4.1

4.1mm
5.0 6.0 7.5 5.0 5.6

5.0mm
6.0 7.5 6.0

6.0mm
6.8 7.5

Pick-Up Impression Coping

IMIC30 IMIC33 IIIC41,IIIC42* IIIC12 IIIC60 IIIC75 IWIP50 IWIP55 IWIP56 IWIP57 IWIP60 IWIP66 IWIP67 N/A IIIC44 IIIC45 IIIC46 IIIC47 IWIT50 IWIT55 IWIT56 IWIT57 IWIT60 IWIT66 IWIT67 IILA20 IILA20 IILA20 IILAW5 IILAW5 IILAW5 IILAW5 IILAW6 IILAW6 IILAW6

Twist Lock Impression Coping N/A Laboratory Analog Laboratory Abutment Holder Abutment Screw Hex Try-In Screw (5-pack) QuickSeat Activator Tool PreFormance Post
*Non-Hexed **Recommended

IMMILA IMMILA IILA20

ILTAH57 IUNIHG**, IUNIHT IUNITS IQSA01 See page 23

Gold Alloy Cylinder Formulation

Melting Range Solidus Liquidus CTE

14001490C (25502710F) 1400C 1490C 13.5 x 10-6 K at 500C

An alloy with a CTE of 10-6 K at 500C is recommended.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

10

Certain Internal Connection

Restorative Products
Screw-Retained Restorations / Certain Internal Connection
UCLA Abutments
Indications: Material:

Single and multi-unit restorations Minimum interarch space of 4mm For aesthetic restorations when tissue is limited
Description

Machined Gold Alloy Cylinder With Plastic Unitube

Item Numbers

3.4mm

Seating Surface

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Castable (Non-Hexed) Castable (Non-Hexed)
4.1mm

IMUCG1C IMUCG2C IMUCG2T** IMUCC2C* IMUCC2T** IGUCA1C IGUCA2C* IGUCA2T** N/A N/A IUNAB2C* IUNAB2T** N/A
Non-Hexed
4.0 11 4.0 11

Seating Surface

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Non-Hexed) Castable (Non-Hexed) Castable (Hexed) 25PK Castable (Non-Hexed) 25PK
5.0mm

Hexed

N/A IWGA51C IWGA52C* IWGA52T** N/A N/A IWPC52C* IWPC52T** IWGA61C IWGA62C* IWGA62T** N/A N/A IWPC62C* IWPC62T** IQSA01

Seating Surface

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Non-Hexed) Castable (Non-Hexed)
6.0mm

Seating Surface
QuickSeat Activator Tool

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Non-Hexed)
All indicated measurements are in millimeters. Castable (Non-Hexed) *Large Diameter Gold-Tite Screw Included. **Large Diameter Ti Screw Included

All indicated measurements are in millimeters.

11

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Screw-Retained Restorations / Certain Internal Connection


UCLA Abutment Cylinder Components
Pick-Up Impression Coping Twist Lock PreFormance Impression Coping Temporary Cylinder Laboratory Analog Laboratory Abutment Holder Abutment Screw QuickSeat Activator Tool

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile

3.4mm
3.4 3.8 4.1

4.1mm
5.0 6.0 7.5 5.0 5.6

5.0mm
6.0 7.5 6.0

6.0mm
6.8 7.5

Pick-Up Impression Coping

IMIC30 IMIC33 IIIC41,IIIC42* IIIC12 IIIC60 IIIC75 IWIP50 IWIP55 IWIP56 IWIP57 IWIP60 IWIP66 IWIP67

Twist Lock Impression Coping N/A Laboratory Analog Laboratory Holder PreFormance Temp. Cylinder Temporary Cylinder Abutment Screw Hex Try-In Screw (5-pack) QuickSeat Activator Tool
*Non-Hexed **Recommended

N/A
IMMILA

IIIC44

IIIC45 IIIC46 IIIC47 IWIT50 IWIT55 IWIT56 IWIT57 IWIT60 IWIT66 IWIT67 IILA20 IILAW5 IILAW6

ILTAH57 N/A N/A hexed N/A non-hexed N/A


hexed non-hexed

IMPFTC34 IMPFTC32 IMMTCS1

N/A

IPFTC41 IPFTC42 IITCS41 IITCS42

IWPFTC51 IWPFTC52 IWTCS51 IWTCS52

IWPFTC61 IWPFTC62 IWTCS61 IWTCS62

Hexed: IUNIHT, IUNIHG** Non-Hexed: ILRGHG**, ILRGHT , IUNITS (for hexed only) IQSA01

Gold Alloy Cylinder Formulation

Melting Range Solidus Liquidus CTE

14001490C (25502710F) 1400C 1490C 13.5 x 10-6 K at 500C

An alloy with a CTE of 10-6 K at 500C is recommended.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

12

Certain Internal Connection

Restorative Products
Screw-Retained Restorations / Certain Internal Connection
Immediate Occlusal Loading (IOL) Abutments*
Indications: Material:

Multi-unit porcelain fused to metal restorations Minimum interarch space of 6mm Minimum tissue height of 2mm
Seating Surface
Collar Height

Titanium Alloy

4.1mm

Emergence Profile

Item Numbers

4.5mm 4.5mm 4.5mm 4.5mm 4.5mm

2.0mm 3.0mm 4.0mm 5.5mm 7.0mm

IIOL20S IIOL30S IIOL40S IIOL55S IIOL70S

4.5

4.1

Uses PAD00 (17mm), PAD24 (24mm) Abutment Driver or RASA3 Driver Tip

*Indications: For surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth, or as a terminal or intermediary abutment for fixed or removable bridgework and to retain overdentures. In addition, when a minimum of 4 implants, 10mm in length, are placed in the mandible and splinted in the anterior region, immediate loading is indicated. All indicated measurements are in millimeters.

13

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Screw-Retained Restorations / Certain Internal Connection


IOL Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder

12.1 9.0 9.3 10.0 3.9 4.5 4.5 4.5 4.5 4.5

Healing Cap

Polishing Protector

Driver And Driver Tip

Retaining And Waxing Screw

4.3 4.5

4.4 4.5

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

Description
Emergence Profile

4.1mm
4.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder Healing Cap Polishing Protector Driver Driver Tip Retaining Screw Waxing Screw

IOLPIC IOLTIC IOLLAS IOLTC IOLGC IOLHC IOLPP PAD00, PAD24 RASA3 GSH30, GSH70 WSK10, MWS15

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

14

Certain Internal Connection

Restorative Products
Screw-Retained Restorations / Certain Internal Connection
Conical Abutments
Indications: Material:

Single and multi-unit porcelain fused to metal restorations Minimum interarch space of 7mm Minimum tissue height of 2mm
h

Titanium Alloy

profile

profile

profile

3.4mm

Seating Surface
Collar Height Item Numbers (Straight) Item Numbers (17 Pre-Angled)* Item Numbers (25 Pre-Angled)*

Emergence Profile

3.4mm 3.4mm 3.4mm 3.4mm


4.1mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm


Collar Height

IMCA31 IMCA32 IMCA33 IMCA34


Item Numbers (Straight)

N/A N/A N/A N/A


Item Numbers (17 Pre-Angled)

N/A N/A N/A N/A


Item Numbers (25 Pre-Angled)

Seating Surface

5.0mm 5.0mm 5.0mm 5.0mm 5.0mm


5.0mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm 5.5mm


Collar Height

ICA001 ICA002 ICA003 ICA004 ICA055


Item Numbers (Straight)

N/A IAC4217 N/A IAC4417 N/A


Item Numbers (17 Pre-Angled)

N/A IAC4225 N/A IAC4425 N/A


Item Numbers (25 Pre-Angled)

Seating Surface

5.0mm 5.0mm 5.0mm 5.0mm 5.0mm


6.0mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm 5.5mm


Collar Height

IWCA51 IWCA52 IWCA53 IWCA54 IWCA55


Item Numbers (Straight)

N/A N/A N/A N/A N/A


Item Numbers (17 Pre-Angled)

N/A N/A N/A N/A N/A


Item Numbers (25 Pre-Angled)

Seating Surface

6.0mm 6.0mm 6.0mm 6.0mm 6.0mm

1.0mm 2.0mm 3.0mm 4.0mm 5.5mm

IWCA61** IWCA62 IWCA63 IWCA64 IWCA65

N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

Uses PAD00 (17mm) or PAD24 (24mm) Abutment Driver or RASA3 Driver Tip.
*It is recommended that small diameter implants not be restored with angled abutments in the molar region. **Requires Gold-Tite Retaining Screw (GSH20)

15

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
Screw-Retained Restorations / Certain Internal Connection
Conical Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Healing Cap Gold And Castable Cylinder

QuickBridge

Temporary Cylinder

Polishing Protector

Retaining Screw

Driver And Driver Tip

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile

3.4mm
3.8 5.0

4.1mm
6.0 7.5 5.0

5.0mm
6.0 7.5 6.0

6.0mm
7.5

Pick-Up single-unit Impression Coping multi-unit


single-unit Twist Lock Impression Coping multi-unit

MEC33 N/A N/A N/A MMCLA MHC33

CNRIC CSQI7 N/A CIC55 CLA20 CS250

CSQN6 CSQ06 N/A CIC56 CLA20 CS260

CSQN7 CSQ07 N/A CIC57 CLA20 CS270

CNRIC CSQ17 N/A CIC55 CLA20 CS250

CSQN6 CSQ06 N/A CIC56 CLA20 CS260

CSQN7 CSQ07 N/A CIC57 CLA20 CS270

WCP661 WCP671 WCP662 N/A WCT661 WCT671 WCT662 WCT672 WCLA6 WCS66 WCLA6 WCS67

Laboratory Analog Healing Cap Gold Cylinder Castable Cylinder Temporary Cylinder QuickBridge Polishing Protector Retaining Screw
single-unit multi-unit single-unit multi-unit single-unit multi-unit multi-unit

MCAG1* MCAG2* N/A N/A MCTC1* MCTC2* N/A PPMC1

CNRG5* CNRG5* CNRG5* CNRG5* CNRG5* CNRG5* CNRG6* CNRG6* CAGC5* CAGC5* CAGC5* CAGC5* CAGC5* CAGC5* CAGC6* CAGC6* CNRC5* CNRC5* CNRC5* CNRC5* CNRC5* CNRC5* N/A CACC5* CACC5* CACC5* CACC5* CACC5* CACC5* N/A N/A N/A

CNC30* CNC30* CNC30* CNC30* CNC30* CNC30* WCTC60* N/A CC300* CC300* CC300* CC300* CC300* CC300* WCTC61* WCTC671* QKBRG QKBRG PPCA3 PPCA3 QKBRG QKBRG PPCA3 PPCA3 QKBRG PPCA3 QKBRG PPCA3 N/A WCPP6 N/A WCPP6

GSH30, GSH70**

GSH20, GSH30, GSH70**

*Requires Gold-Tite Retaining Screw. **Height of screw may be adjusted to access hole depth.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

16

Certain Internal Connection

Restorative Products
OverdentSURE Restorations / Certain Internal Connection

Immediate Occlusal Loading (IOL) Abutments


Indications: Material:

Multiple implant bar retained and fixed removable overdentures Minimum interarch space of 6.5mm Maximum angulation of 30
Immediate Occlusal Loading:

Titanium Alloy

Adequate bone quality equal to or greater than Type III Bone height equal to or greater than 12mm to allow for a minimum 10mm implant Bone width equal to or greater than 6mm to allow for a minimum 4mm diameter implant Adequate curvature of the arch and space between mental foramina, to permit proper anterior/posterior spread measurement, will allow functional cantilevers to 1st molar occlusion

4.1mm

Seating Surface
Collar Height Item Numbers

Emergence Profile

4.5mm 4.5mm 4.5mm 4.5mm 4.5mm

2.0mm 3.0mm 4.0mm 5.5mm 7.0mm

IIOL20S IIOL30S IIOL40S IIOL55S IIOL70S

4.5

4.1

Uses PAD00 (17mm), PAD24 (24mm) Abutment Driver or RASA3 Driver Tip

All indicated measurements are in millimeters.

17 17

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / Certain Internal Connection

IOL Abutment Components


Laboratory Analog Temporary Cylinder Gold Cylinder

12.1 9.0 9.3 10.0 3.9 4.5 4.5 4.5 4.5 4.5

Distal Extension

Healing Cap

Polishing Protector

Driver And Driver Tip

Retaining And Waxing Screw

4.3 2.8 7.9 4.5

4.4 4.5

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

Description
Emergence Profile

4.1mm
4.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder Distal Extension Healing Cap Polishing Protector Driver Driver Tip Retaining Screw Waxing Screw

IOLPIC IOLTIC IOLLAS IOLTC IOLGC IOLDE IOLHC IOLPP PAD00, PAD24 RASA3 GSH30, GSH70 WSK10, MWS15

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

18 18

Certain Internal Connection

Pick-Up Impression Coping

Twist Lock Impression Coping

Restorative Products
OverdentSURE Restorations / Certain Internal Connection
Standard Abutments
Indications: Material:

Multiple implant bar retained and fixed removable overdentures Minimum interarch space of 6.5mm Maximum divergence of 30
4.1mm

Titanium Alloy

Seating Surface
Item Numbers

Collar Height

2.0mm 3.0mm 4.0mm 5.5mm 7.0mm


5.0mm

IAB200* IAB300 IAB400 IAB550


profile h

IAB700
Item Numbers

Seating Surface

Collar Height

2.0mm 3.0mm 4.0mm 5.5mm


Uses PAD00 (17mm) or PAD24 (24mm) Abutment Driver or RASA3 Driver Tip.
*Requires Gold-Tite Retaining Screw (GSH20)

N/A N/A N/A N/A

19

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / Certain Internal Connection
Standard Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Gold Cylinder Temporary Cylinder

Polishing Protector

Healing Cap

Retaining Screw

Driver And Driver Tip

LOCATOR Bar Attachment

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile

4.1mm
4.5

5.0mm
5.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Gold Cylinder Chamfered Gold Cylinder Castable Gold Cylinder LOCATOR Bar Attachment LOCATOR Bar Attachment Tap LOCATOR Drill Gold Hader Clip Plastic Hader Clip Temporary Cylinder Polishing Protector Healing Cap Retaining Screw

SQIC7 SIC70 SLA20 SGC30** CGC30** SGC34** LOAB* LOAT LOAD ORCG1 ORCY1 TC300** PPSA3 TS250 GSH20, GSH30, GSH70***

SQIC7 SIC70 SLA20 SGC30** CGC30** SGC34** LOAB* LOAT LOAD ORCG1 ORCY1 TC300** PPSA3 TS250 GSH20, GSH30, GSH70***

*Includes LOCATOR Attachment, Housing, Processing Male, Spacer Males, 3 Retention Replacement Males **Requires Gold-Tite Retaining Screw (GSH30, GSH70). ***Height of screw may be adjusted to access hole depth.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

20

Certain Internal Connection

Restorative Products
OverdentSURE Restorations / Certain Internal Connection

LOCATOR Abutments
Indications: Material:

Tissue supported removable overdentures on 2 to 4 implants Partially edentulous overdentures with one or more implants Limited interarch distance Angle correction with up to 40 between divergent implants
3.4mm

Abutment: Titanium Alloy With Titanium Nitride Coating Housing: Titanium Alloy Males: Nylon

Seating Surface
Item Numbers

Collar Height

1.0mm 2.0mm 3.0mm 4.0mm 5.0mm 6.0mm


4.1mm

IMLOA001 IMLOA002 IMLOA003 IMLOA004 IMLOA005 IMLOA006


Item Numbers
3.4

height

Seating Surface

Collar Height

1.0mm 2.0mm 3.0mm 4.0mm 5.0mm 6.0mm

ILOA001 ILOA002 ILOA003 ILOA004 ILOA005 ILOA006


4.1

height

Included With Each Abutment:

Housing and Black Processing Male

All indicated measurements are in millimeters.

21

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

{ { { { {
Final Male Light Retention Male White Extra Spacer Ring Light Retention Male

Restorative Products
OverdentSURE Restorations / Certain Internal Connection

LOCATOR Abutment Components


Impression Coping Laboratory Analog Retention Males Core Tool / Driver And Driver Tip

Description

Item Numbers

Impression Coping Laboratory Analog Extra Light Retention Males (4-pack) - Blue, 1.5lbs/680g Extended Range Males (4-pack) - Green, 4lbs/1800g Extra Light Retention Extended Range Males - Red, 1.5lbs/680g Replacement Males (4-pack) - White, 5lbs/2250g Light Retention Replacement Males (4-pack) - Pink, 3lbs/1350g Replacement Housing Replacement Housing Kit Core Tool/Abutment Driver Driver Tip 24mm(L) Driver Tip 30mm(L) 1.25mm/.050in. Driver Tip 24mm(L) - used with LCTDR1 1.25mm/.050in. Driver Tip 30mm(L) - used with LCTDR1 LOCATOR Bar Attachment LOCATOR Bar Attachment Tap LOCATOR Bar Attachment Drill

LAIC1 LALA1 LAELM LAERM LELARM LARMS LLRMS LOAH LORHK* LCTDR1 LOADT4 LOADT9
Extra Light White Retention Male Spacer Ring Housing and Black Final Male LOCATOR Light Processing Male Retention Male

*Included With LORHK Replacement Housing Kit:

RASH9 LOAB LOAT LOAD

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

{ {

RASH4

{ {

22

Certain Internal Connection

Restorative Products
Provisional Restorations / Certain Internal Connection

PreFormance Posts
Indications: Material:

Single and multiple unit provisional cement-retained restorations PEEK: Titanium Alloy Connection Minimum interarch space of 6mm Maximum angulation of 15 Intraoral use limited to 180 days Immediate nonocclusal loading of single-unit provisional restorations Multiple unit restorations will require an evaluation of occlusal forces in lateral and protrusive excursions and masticatory forces to minimize the load on the provisional restorations Guided soft tissue healing of single and multiple unit restorations of integrated implants
7.0 7.0

profile

profile

3.4mm

Seating Surface
Collar Height Item Numbers (Straight) Item Numbers (15 Pre-Angled)

Emergence Profile

3.8mm 3.8mm
4.1mm
Emergence Profile

4.0mm 6.0mm
Collar Height

IMPFP34 IMPFP36
Item Numbers (Straight)

IMPAPF34 IMPAPF36
Item Numbers (15 Pre-Angled)

Seating Surface

5.0mm 5.0mm
5.0mm
Emergence Profile

4.0mm 6.0mm
Collar Height

IPFP454 IPFP456
Item Numbers (Straight)

IPAPF454 IPAPF456
Item Numbers (15 Pre-Angled)

Seating Surface

5.0mm 5.0mm
6.0mm
Emergence Profile

4.0mm 6.0mm
Collar Height

IWPFP554 IWPFP556
Item Numbers (Straight)

IPAPF554 IPAPF556
Item Numbers (15 Pre-Angled)

Seating Surface

6.0mm 6.0mm

4.0mm 6.0mm

IWPFP664 IWPFP666

IPAPF664 IPAPF666

All indicated measurements are in millimeters.

23

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
Provisional Restorations / Certain Internal Connection

Temporary Cylinders
Indications:

Single and multiple unit provisional screw-retained restorations Minimum interarch space of 6mm Maximum angulation of 15 Intraoral use limited to 180 days Immediate nonocclusal loading of single-unit provisional restorations Multiple unit restorations will require an evaluation of prosthesis support to minimize the load on the provisional abutments Occlusal loading of single and multiple unit restorations of integrated implants for guided tissue healing

PEEK: Titanium Alloy Connection

Description

Item Numbers

3.4mm

Seating Surface

Hexed Non-Hexed
4.1mm

IMPFTC34 IMPFTC32 IPFTC41


10.0

Seating Surface

Hexed Non-Hexed
5.0mm

IPFTC42 IWPFTC51 IWPFTC52 IWPFTC61 IWPFTC62

Seating Surface

Hexed Non-Hexed
6.0mm

Seating Surface

Hexed Non-Hexed

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

24

Certain Internal Connection

Material:

Restorative Products
Cement-Retained Restorations / External Hex Connection

GingiHue Posts
Indications: Material:

Single and multi-unit porcelain fused to metal restorations Areas of thin tissue where gingival discoloration is possible Preparable to follow gingival contours Conventional crown and bridge procedures Maximum angulation correction of 15 Minimum interarch space of 6mm
7.0

Straight Post (Commercially Pure Titanium) Pre-Angled Post (Titanium Alloy)

Prep-Tite Cap For Straight GingiHue Posts


7.0 h profile

h profile

3.4mm

Seating Surface
Collar Height Item Numbers (Straight) Item Numbers (15 Pre-Angled) Height Item Numbers

Emergence Profile

3.8mm 3.8mm
4.1mm
Emergence Profile

2.0mm 4.0mm
Collar Height

MAP32G MAP34G
Item Numbers (Straight)

MPAP32G MPAP34G
Item Numbers (15 Pre-Angled)

7mm 7mm
Height

PTC347 PTC347
Item Numbers

Seating Surface

5.0mm 5.0mm 6.0mm 6.0mm 7.5mm 7.5mm


5.0mm
Emergence Profile

2.0mm 4.0mm 2.0mm 4.0mm 2.0mm 4.0mm


Collar Height

APP452G APP454G APP462G APP464G APP472G APP474G


Item Numbers (Straight)

PAP452G PAP454G PAP462G PAP464G PAP472G PAP474G


Item Numbers (15 Pre-Angled)

7mm 7mm 7mm 7mm 7mm 7mm


Height

PTC457 PTC457 PTC467 PTC467 PTC477 PTC477


Item Numbers

Seating Surface

5.0mm 5.0mm 6.0mm 6.0mm 7.5mm 7.5mm


6.0mm
Emergence Profile

2.0mm 4.0mm 2.0mm 4.0mm 2.0mm 4.0mm


Collar Height

WPP552G WPP554G WPP562G WPP564G WPP572G WPP574G


Item Numbers (Straight)

PAP552G PAP554G PAP562G PAP564G PAP572G PAP574G


Item Numbers (15 Pre-Angled)

7mm 7mm 7mm 7mm 7mm 7mm


Height

PTC557 PTC557 PTC467 PTC467 PTC477 PTC477


Item Numbers

Seating Surface

6.0mm 6.0mm 7.5mm

2.0mm 4.0mm 2.0mm

WPP662G WPP664G WPP672G WPP674G

PAP662G PAP664G PAP672G PAP674G

7mm 7mm 7mm 7mm

PTC667 PTC667 PTC477 PTC477

All indicated measurements4.0mm 7.5mm are in millimeters.

All indicated measurements are in millimeters.

25

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
Cement-Retained Restorations / External Hex Connection

GingiHue Post Components


Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog PreFormance Post Laboratory Abutment Holder Abutment Screw

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Square Driver PSQD0N, PSQD1N or Driver Tip RASQ3N, RASQ8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile

3.4mm
3.8 5.0

4.1mm
6.0 7.5 5.0

5.0mm
6.0 7.5 6.0

6.0mm
7.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Laboratory Abutment Holder Abutment Screw Square Try-In Screw (5-pack) PreFormance Post
*Non-Hexed **Recommended

MIC33 N/A MMILA LTAH5

IIC12 IIC45 ILA20 LTAH7

IIC60 IIC46 ILA20 LTAH7

IIC75 IIC47 ILA20 LTAH7

WIP55 WIT55 ILAW5 LTAH7

WIP56 WIT56 ILAW5 LTAH7

WIP57 WIT57 ILAW5 LTAH7

WIP66 WIT66 ILAW6 LTAH7

WIP67 WIT67 ILAW6 LTAH7

UNISG** UNIHG, UNIHT , MUNITS UNITS See page 47

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

26

External Hex Connection

Restorative Products
Cement-Retained Restorations / External Hex Connection

ZiReal Posts
Indications: Material:

Single and multi-unit all ceramic restorations Preparable to follow gingival contours Minimum interarch space of 6mm Aesthetic restorations when tissue is limited Maximum angulation of 10
4.1mm

Zirconia Ceramic With A Titanium Alloy Interface

Seating Surface
Collar Height Item Numbers

Emergence Profile

5.0mm 6.0mm
5.0mm
Emergence Profile

4.0mm 4.0mm
Collar Height

CAP454
7.0

CAP464
h

Seating Surface
Item Numbers
profile

6.0mm 7.5mm

4.0mm 4.0mm

WCAP564 WCAP574

All indicated measurements are in millimeters.

27

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
Cement-Retained Restorations / External Hex Connection

ZiReal Post Components


Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog PreFormance Post Laboratory Abutment Holder Abutment Screw

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Square Driver PSQD0N, PSQD1N or Driver Tip RASQ3N, RASQ8N

= Requires the use of Impression Coping Driver ICD00

Description
Emergence Profile 5.0

4.1mm
6.0 7.5 5.0

5.0mm
6.0 7.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Laboratory Abutment Holder Abutment Screw Square Try-In Screw (5-pack) PreFormance Post
*Recommended

IIC12 IIC45 ILA20

IIC60 IIC46 ILA20

IIC75 IIC47 ILA20 LTAH7

WIP55 WIT55 ILAW5

WIP56 WIT56 ILAW5

WIP57 WIT57 ILAW5

UNISG*, UNIHG, UNIHT UNITS See page 47

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

28

External Hex Connection

Restorative Products
Cement-Retained Restorations / External Hex Connection
UCLA Abutments
Indications: Material:

Laboratory fabricated custom abutments Single and multi-unit restorations Minimum interarch space of 6mm For aesthetic restorations when tissue is limited Maximum angulation correction of 30

Machined Gold Alloy Cylinder With Plastic Unitube

Description

Item Numbers

3.4mm 4.1mm

Seating Surface

Gold (Hexed)
Seating Surface

MUCG1C GUCA1C SGUCA1C UNAB1C UNA125


Hexed
4.0 11

Gold (Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Hexed) 25PK
5.0mm

Seating Surface

Gold (Hexed) Gold Standard ZR (Hexed) Castable (Hexed)


6.0mm

WGA51C SWGA51C WPC51C WGA61C SWGA61C WPC61C

Seating Surface

Gold (Hexed) Gold Standard ZR (Hexed) Castable (Hexed)

All indicated measurements are in millimeters.

29

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Cement-Retained Restorations / External Hex Connection


UCLA Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog PreFormance Post Laboratory Abutment Holder Abutment Screw

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

= Requires the use of Square Driver PSQD0N, PSQD1N or Driver Tip RASQ3N, RASQ8N

Description
Emergence Profile

3.4mm
3.8 5.0

4.1mm
6.0 7.5 5.0

5.0mm
6.0 7.5 6.0

6.0mm
7.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Laboratory Abutment Holder Abutment Screw Square Try-In Screw (5-pack) PreFormance Post
*Non-Hexed **Recommended

MIC33 N/A MMILA LTAH5

IIC12 IIC45 ILA20 LTAH7

IIC60 IIC46 ILA20 LTAH7

IIC75 IIC47 ILA20 LTAH7

WIP55 WIT55 ILAW5 LTAH7

WIP56 WIT56 ILAW5 LTAH7

WIP57 WIT57 ILAW5 LTAH7

WIP66 WIT66 ILAW6 LTAH7

WIP67 WIT67 ILAW6 LTAH7

UNISG** UNIHG, UNIHT , MUNITS UNITS See page 47

Gold Alloy Cylinder Formulation

Melting Range Solidus Liquidus CTE

14001490C (25502710F) 1400C 1490C 13.5 x 10-6 K at 500C

An alloy with a CTE of 10-6 K at 500C is recommended.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

30

External Hex Connection

Restorative Products
Screw-Retained Restorations / External Hex Connection
UCLA Abutments
Indications: Material:

Single and multi-unit restorations Minimum interarch space of 4mm For aesthetic restorations when tissue is limited
Description

Machined Gold Alloy Cylinder With Plastic Unitube

Item Numbers

3.4mm

Seating Surface

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Castable (Non-Hexed) Castable (Non-Hexed)
4.1mm

MUCG1C MUCG2C N/A MUCC2C N/A GUCA1C GUCA2C N/A


Hexed
4.0

Seating Surface
11

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Non-Hexed) Castable (Non-Hexed) Castable (Hexed) 25PK Castable (Non-Hexed) 25PK
5.0mm

SGUCA1C UNAB1C UNAB2C N/A UNA125 UNA225 WGA51C WGA52C N/A SWGA51C WPC51C WPC52C N/A WGA61C WGA62C N/A SWGA61C WPC61C WPC62C N/A
4.0 11

Non-Hexed

Seating Surface

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Non-Hexed) Castable (Non-Hexed)
6.0mm

Seating Surface

Gold (Hexed) Gold (Non-Hexed) Gold (Non-Hexed) Gold Standard ZR (Hexed) Castable (Hexed) Castable (Non-Hexed)
All indicated measurements are in millimeters. Castable (Non-Hexed)

All indicated measurements are in millimeters.

31

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Screw-Retained Restorations / External Hex Connection


UCLA Abutment Cylinder Components
Pick-Up Impression Coping Twist Lock Impression Coping PreFormance Temporary Cylinder Laboratory Analog Laboratory Abutment Holder Abutment Screw

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

= Requires the use of Square Driver PSQD0N, PSQD1N or Driver Tip RASQ3N, RASQ8N

Description
Emergence Profile

3.4mm
3.8 5.0

4.1mm
6.0 7.5 5.0

5.0mm
6.0 7.5 6.0

6.0mm
7.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Laboratory Holder PreFormance Temp. Cylinder Temporary Cylinder Abutment Screw
hexed non-hexed hexed non-hexed

MIC33 N/A MMILA LTAH5 MPFTC34 MPFTC32 MMTCS1 N/A

IIC12 IIC45

IIC60 IIC46 ILA20 LTAH7 PFTC41 PFTC42 ITCS41 ITCS42

IIC75 IIC47

WIP55 WIT55

WIP56 WIT56 ILAW5 LTAH7 WPFTC51 WPFTC52 WTCS51 WTCS52

WIP57 WIT57

WIP66 WIT66

WIP67 WIT67

ILAW6 LTAH7 WPFTC61 WPFTC62 WTCS61 WTCS62

UNISG*, UNIHG, UNIHT UNITS

Square Try-In Screw (5-pack) MUNITS All indicated measurements are in millimeters.
*Recommended

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

32

External Hex Connection

Restorative Products
Screw-Retained Restorations / External Hex Connection
Immediate Occlusal Loading (IOL) Abutments*
Indications: Material:

Multi-unit porcelain fused to metal restorations Minimum interarch space of 6mm Minimum tissue height of 2mm
Seating Surface
Collar Height

Titanium Alloy

4.1mm

Emergence Profile

Item Numbers

4.5mm 4.5mm 4.5mm 4.5mm 4.5mm

2.0mm 3.0mm 4.0mm 5.5mm 7.0mm

IOL20T IOL30T IOL40T


h 4.5

IOL55T IOL70T
4.1

Uses PAD00 (17mm), PAD24 (24mm) Abutment Driver or RASA3 Driver Tip

*Indications: For surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth, or as a terminal or intermediary abutment for fixed or removable bridgework and to retain overdentures. In addition, when a minimum of 4 implants, 10mm in length, are placed in the mandible and splinted in the anterior region, immediate loading is indicated. All indicated measurements are in millimeters.

33

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Screw-Retained Restorations / External Hex Connection


IOL Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder

12.1 9.0 9.3 10.0 3.9 4.5 4.5 4.5 4.5 4.5

Healing Cap

Polishing Protector

Driver And Driver Tip

Retaining And Waxing Screw

4.3 4.5

4.4 4.5

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

Description
Emergence Profile

4.1mm
4.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder Healing Cap Polishing Protector Driver Driver Tip Retaining Screw Waxing Screw

IOLPIC IOLTIC IOLLAS IOLTC IOLGC IOLHC IOLPP PAD00, PAD24 RASA3 GSH30, GSH70 WSK10, MWS15

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

34

External Hex Connection

Restorative Products
Screw-Retained Restorations / External Hex Connection
Conical Abutments
Indications: Material:

Single and multi-unit porcelain fused to metal restorations Minimum interarch space of 7mm Minimum tissue height of 2mm

Angled (Titanium Alloy) Straight (Commercially Pure Titanium)

h h profile profile profile h

3.4mm

Seating Surface
Collar Height Item Numbers (Straight) Item Numbers (17 Pre-Angled) Item Numbers (25 Pre-Angled)

Emergence Profile

3.4mm 3.4mm 3.4mm 3.4mm


4.1mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm


Collar Height

MCA31 MCA32 MCA33 MCA34


Item Numbers (Straight)

N/A N/A N/A N/A


Item Numbers (17 Pre-Angled)

N/A N/A N/A N/A


Item Numbers (25 Pre-Angled)

Seating Surface

5.0mm 5.0mm 5.0mm 5.0mm 5.0mm


5.0mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm 5.5mm


Collar Height

SCA001 SCA002 SCA003 SCA004 SCA055


Item Numbers (Straight)

N/A AC4217 N/A AC4417 N/A


Item Numbers (17 Pre-Angled)

N/A AC4225 N/A AC4425 N/A


Item Numbers (25 Pre-Angled)

Seating Surface

5.0mm 5.0mm 5.0mm 5.0mm 5.0mm


6.0mm
Emergence Profile

1.0mm 2.0mm 3.0mm 4.0mm 5.5mm


Collar Height

SWCA51 SWCA52 SWCA53 SWCA54 SWCA55


Item Numbers (Straight)

N/A N/A N/A N/A N/A


Item Numbers (17 Pre-Angled)

N/A N/A N/A N/A N/A


Item Numbers (25 Pre-Angled)

Seating Surface

6.0mm 6.0mm 6.0mm 6.0mm 6.0mm

1.0mm 2.0mm 3.0mm 4.0mm 5.5mm

SWCA61* SWCA62 SWCA63 SWCA64 SWCA65

N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A

Uses PAD00 (17mm) or PAD24 (24mm) Abutment Driver or RASA3 Driver Tip.
*Requires use of GSH20 Retaining Screw.

35

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
Screw-Retained Restorations / External Hex Connection
Conical Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Healing Cap Gold And Castable Cylinder

QuickBridge

Temporary Cylinder

Polishing Protector

Retaining Screw

Driver And Driver Tip

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

Description
Emergence Profile

3.4mm
3.8 5.0

4.1mm
6.0 7.5 5.0

5.0mm
6.0 7.5 6.0

6.0mm
7.5

Pick-Up single-unit Impression Coping multi-unit


single-unit Twist Lock Impression Coping multi-unit

MEC33 N/A N/A N/A MMCLA MHC33

CNRIC CSQI7 N/A CIC55 CLA20 CS250

CSQN6 CSQ06 N/A CIC56 CLA20 CS260

CSQN7 CSQ07 N/A CIC57 CLA20 CS270

CNRIC CSQ17 N/A CIC55 CLA20 CS250

CSQN6 CSQ06 N/A CIC56 CLA20 CS260

CSQN7 CSQ07 N/A CIC57 CLA20 CS270

WCP661 WCP671 WCP662 N/A WCT661 WCT671 WCT662 WCT672 WCLA6 WCS66 WCLA6 WCS67

Laboratory Analog Healing Cap Gold Cylinder Castable Cylinder Temporary Cylinder QuickBridge Polishing Protector Retaining Screw
single-unit multi-unit single-unit multi-unit single-unit multi-unit multi-unit

MCAG1* MCAG2* N/A N/A MCTC1* MCTC2* N/A PPMC1

CNRG5* CNRG5* CNRG5* CNRG5* CNRG5* CNRG5* CNRG6* CNRG6* CAGC5* CAGC5* CAGC5* CAGC5* CAGC5* CAGC5* CAGC6* CAGC6* CNRC5* CNRC5* CNRC5* CNRC5* CNRC5* CNRC5* N/A CACC5* CACC5* CACC5* CACC5* CACC5* CACC5* N/A N/A N/A

CNC30* CNC30* CNC30* CNC30* CNC30* CNC30* WCTC60* N/A CC300* CC300* CC300* CC300* CC300* CC300* WCTC61* WCTC671* QKBRG QKBRG PPCA3 PPCA3 QKBRG QKBRG PPCA3 PPCA3 QKBRG PPCA3 QKBRG PPCA3 N/A WCPP6 N/A WCPP6

GSH30, GSH70**

GSH20, GSH30, GSH70**

*Requires Gold-Tite Retaining Screw **Height of screw may be adjusted to access hole depth.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

36

External Hex Connection

= Requires the use of Impression Coping Driver ICD00

Restorative Products
OverdentSURE Restorations / External Hex Connection
Immediate Occlusal Loading (IOL) Abutments
Indications: Material:

Multiple implant bar retained and fixed removable overdentures Minimum interarch space of 6.5mm Maximum angulation of 30
Immediate Occlusal Loading:

Titanium Alloy

Adequate bone quality equal to or greater than Type III Bone height equal to or greater than 12mm to allow for a minimum 10mm implant Bone width equal to or greater than 6mm to allow for a minimum 4mm diameter implant Adequate curvature of the arch and space between mental foramina, to permit proper anterior/posterior spread measurement, will allow functional cantilevers to 1st molar occlusion

4.1mm

Seating Surface
Collar Height Item Numbers

Emergence Profile

4.5mm 4.5mm 4.5mm 4.5mm 4.5mm

2.0mm 3.0mm 4.0mm 5.5mm 7.0mm

IOL20T IOL30T IOL40T


h 4.5

IOL55T IOL70T
4.1

Uses PAD00 (17mm), PAD24 (24mm) Abutment Driver or RASA3 Driver Tip

All indicated measurements are in millimeters.

37

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / External Hex Connection
IOL Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder

12.1 9.0 9.3 10.0 3.9 4.5 4.5 4.5 4.5 4.5

Distal Extension

Healing Cap

Polishing Protector

Driver And Driver Tip

Retaining And Waxing Screw

4.3 2.8 7.9 4.5

4.4 4.5

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

Description
Emergence Profile

4.1mm
4.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Temporary Cylinder Gold Cylinder Distal Extension Healing Cap Polishing Protector Driver Driver Tip Retaining Screw Waxing Screw

IOLPIC IOLTIC IOLLAS IOLTC IOLGC IOLDE IOLHC IOLPP PAD00, PAD24 RASA3 GSH30, GSH70 WSK10, MWS15

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

38

External Hex Connection

Restorative Products
OverdentSURE Restorations / External Hex Connection
Standard Abutments
Indications: Material:

Multiple implant bar retained and fixed removable overdentures Minimum interarch space of 6.5mm Maximum divergence of 30
4.1mm

Commercially Pure Titanium

Seating Surface
Item Numbers

Collar Height

2.0mm 3.0mm 4.0mm 5.5mm 7.0mm


5.0mm

AB200* AB300
h

AB400 AB550 AB700


Item Numbers

Seating Surface

Collar Height

2.0mm 3.0mm 4.0mm 5.5mm


Uses PAD00 (17mm) or PAD24 (24mm) Abutment Driver or RASA3 Driver Tip.
*Requires Gold-Tite Retaining Screw (GSH20)

WAB200* WAB300 WAB400 WAB550

Temporary Healing Retention Cylinder


Retains denture with soft tissue liner.

THRC4
4.1mm(D) x 4mm(H)

THRC6
4.1mm(D) x 6mm(H)

All indicated measurements are in millimeters.

39

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / External Hex Connection
Standard Abutment Components
Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Gold Cylinder Temporary Cylinder

Polishing Protector

Healing Cap

Retaining Screw

Driver And Driver Tip

LOCATOR Bar Attachment

Description
Emergence Profile

4.1mm
4.5

5.0mm
5.5

Pick-Up Impression Coping Twist Lock Impression Coping Laboratory Analog Gold Cylinder Chamfered Gold Cylinder Castable Plastic Cylinder LOCATOR Bar Attachment LOCATOR Bar Attachment Tap LOCATOR Drill Gold Hader Clip Plastic Hader Clip Temporary Cylinder Polishing Protector Healing Cap Retaining Screw

SQIC7 SIC70 SLA20 SGC30** CGC30** SGC34** LOAB* LOAT LOAD ORCG1 ORCY1 TC300** PPSA3 TS250 GSH20, GSH30, GSH70***

SQIC7 SIC70 SLA20 SGC30** CGC30** SGC34** LOAB* LOAT LOAD ORCG1 ORCY1 TC300** PPSA3 TS250 GSH20, GSH30, GSH70***

*Includes LOCATOR Attachment, Housing, Processing Male, Spacer Males, 3 Retention Replacement Males **Requires Gold-Tite Retaining Screw (GSH30, GSH70). ***Height of screw may be adjusted to access hole depth.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

40

External Hex Connection

= Requires the use of Hex Driver PHD02N, PHD03N or Driver Tip RASH3N, RASH8N

= Requires the use of Impression Coping Driver ICD00

Restorative Products
OverdentSURE Restorations / External Hex Connection

LOCATOR Abutments
Indications: Material:

Tissue supported removable overdentures on 2 to 4 implants Partially edentulous overdentures with one or more implants Limited interarch distance Angle correction with up to 40 between divergent implants
3.4mm

Abutment: Titanium Alloy With Titanium Nitride Coating Housing: Titanium Alloy Males: Nylon

Seating Surface
Item Numbers

Collar Height

1.0mm 2.0mm 3.0mm 4.0mm 5.0mm 6.0mm


4.1mm

MLOA001
height

MLOA002 MLOA003
3.4

MLOA004 MLOA005 MLOA006


Item Numbers

Seating Surface

Collar Height

1.0mm 2.0mm 3.0mm 4.0mm 5.0mm 6.0mm

LOA001
height

LOA002 LOA003 LOA004 LOA005 LOA006


4.1

Included With Each Abutment:

Temporary Healing Retention Cylinder


Retains denture with soft tissue liner.

Housing and Black Processing Male

{ { { { {
Final Male Light Retention Male White Extra Spacer Ring Light Retention Male

THRC4
4.1mm(D) x 4mm(H)

THRC6
4.1mm(D) x 6mm(H)

All indicated measurements are in millimeters.

41

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / External Hex Connection

LOCATOR Abutment Components


Impression Coping Laboratory Analog Retention Males Core Tool / Driver And Driver Tip

Description

Item Numbers

Impression Coping Laboratory Analog Extra Light Retention Males (4-pack) - Blue, 1.5lbs/680g Extended Range Males (4-pack) - Green, 4lbs/1800g Extra Light Retention Extended Range Males - Red, 1.5lbs/680g Replacement Males (4-pack) - White, 5lbs/2250g Light Retention Replacement Males (4-pack) - Pink, 3lbs/1350g Replacement Housing Replacement Housing Kit Core Tool/Abutment Driver Driver Tip 24mm(L) Driver Tip 30mm(L) 1.25mm/.050in. Driver Tip 24mm(L) - used with LCTDR1 1.25mm/.050in. Driver Tip 30mm(L) - used with LCTDR1 LOCATOR Bar Attachment LOCATOR Bar Attachment Tap LOCATOR Bar Attachment Drill

LAIC1 LALA1

LAERM LELARM LARMS LLRMS LOAH LORHK* LCTDR1 LOADT4 LOADT9

*Included With LORHK Replacement Housing Kit:

Housing and Black Final Male LOCATOR Light Processing Male Retention Male

RASH9 LOAB LOAT LOAD

Extra Light White Retention Male Spacer Ring

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

{ {

RASH4

42

External Hex Connection

LAELM

{ {

Restorative Products
OverdentSURE Restorations / External Hex Connection

O-Ring Abutments
Indications: Material:

Abutment: Commercially Pure Titanium Tissue supported overdenture retained by 2 or more implants O-Ring: Buna Partial overdentures Housing: Titanium Alloy Resilient retention Minimum interarch space of 7mm Maximum tissue height of 6mm Recommended for parallel implants; (see castable O-Ring system for divergent implants) 850 grams of retention

4.1mm

Seating Surface
Item Numbers
2.5

Collar Height

2.0mm 4.0mm 6.0mm


5.0mm

OSO20 OSO40 OSO60


4.1 h

Seating Surface
Item Numbers

Collar Height

2.0mm 4.0mm 6.0mm

WOSO20 WOSO40 WOSO60

Included With Each Abutment:

Temporary Healing Retention Cylinder


Retains denture with soft tissue liner.

2.0

{ {
Final O-Ring Processing O-Ring

5.0

Domed Housing

THRC4
4.1mm(D) x 4mm(H)

THRC6
4.1mm(D) x 6mm(H)

All indicated measurements are in millimeters.

43

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / External Hex Connection

O-Ring Abutment Components


Laboratory Analog Housing O-Ring Driver And Driver Tip

Description

Item Numbers

Laboratory Analog Housing O-Ring Replacement Red Processing O-Ring O-Ring/Dal-Ro Abutment Driver O-Ring/Dal-Ro Abutment Driver Tip Castable System
*Use with UCLA Abutment to realign non-parallel implants or on distal of overdenture bar.

ORLAU OSODH OSOBLK OSORED PAD01 RAOR1 OSOCA*

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

44

External Hex Connection

Restorative Products
OverdentSURE Restorations / External Hex Connection

Dal-Ro Abutments
Indications: Material:

Tissue supported overdentures Abutment: Titanium Alloy Partial overdentures Housing: Titanium Rigid retention Females: Gold Alloy Minimum interarch space of 5mm Maximum tissue height of 6mm Recommended for parallel implants; (see castable Dal-Ro system for divergent implants) 2501000 grams of retention; may be adjusted

4.1mm

Seating Surface
Item Numbers
2.25

Emergence Profile

2.0mm 4.0mm 6.0mm

DRH20 DRH40 DRH60


4.1 h

Included With Each Abutment:


3.1

Temporary Healing Retention Cylinder


Retains denture with soft tissue liner.

Dal-Ro Housing And Female Attachment

THRC4
4.1mm(D) x 4mm(H)

THRC6
4.1mm(D) x 6mm(H)

All indicated measurements are in millimeters.

45

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Restorative Products
OverdentSURE Restorations / External Hex Connection

Dal-Ro Abutment Components


Laboratory Analog Housing/Female Assembly Replacement Female Female Adjustment Tool Driver And Driver Tip

Description

Item Numbers

Laboratory Analog Housing/Female Assembly Replacement Female Female Adjustment Tool O-Ring/Dal-Ro Abutment Driver O-Ring/Dal-Ro Abutment Driver Tip Castable System
*Use with UCLA Abutment to realign non-parallel implants or on distal of hader bar.

DRLAU DRTH

DRFAT1 PAD01 RAOR1 DRCS1*

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

46

External Hex Connection

DRAF

Restorative Products
Provisional Restorations / External Hex Connection

PreFormance Posts
Indications: Material:

Single and multiple unit provisional cement-retained restorations PEEK: Titanium Alloy Connection Minimum interarch space of 6mm Maximum angulation of 15 Intraoral use limited to 180 days Immediate nonocclusal loading of single-unit provisional restorations Multiple unit restorations will require an evaluation of occlusal forces in lateral and protrusive excursions and masticatory forces to minimize the load on the provisional restorations Guided soft tissue healing of single and multiple unit restorations of integrated implants

7.0

7.0

h profile profile

3.4mm

Seating Surface
Collar Height Item Numbers (Straight) Item Numbers (15 Pre-Angled)

Emergence Profile

3.8mm 3.8mm
4.1mm
Emergence Profile

4.0mm 6.0mm
Collar Height

MPFP34 MPFP36
Item Numbers (Straight)

MPAPF34 MPAPF36
Item Numbers (15 Pre-Angled)

Seating Surface

5.0mm 5.0mm
5.0mm
Emergence Profile

4.0mm 6.0mm
Collar Height

PFP454 PFP456
Item Numbers (Straight)

PAPF454 PAPF456
Item Numbers (15 Pre-Angled)

Seating Surface

5.0mm 5.0mm
6.0mm
Emergence Profile

4.0mm 6.0mm
Collar Height

WPFP554 WPFP556
Item Numbers (Straight)

PAPF554 PAPF556
Item Numbers (15 Pre-Angled)

Seating Surface

6.0mm 6.0mm

4.0mm 6.0mm

WPFP664 WPFP666

PAPF664 PAPF666

All PreFormance Posts are packaged with a Titanium Hexed Screw (UNIHT).

All indicated measurements are in millimeters.

47

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Provisional Restorations / External Hex Connection

Temporary Cylinders
Indications: Material:

Single and multiple unit provisional screw-retained restorations Minimum interarch space of 6mm Maximum angulation of 15 Intraoral use limited to 180 days Immediate nonocclusal loading of single-unit provisional restorations Multiple unit restorations will require an evaluation of prosthesis support to minimize the load on the provisional abutments Occlusal loading of single and multiple unit restorations of integrated implants for guided tissue healing

PEEK: Titanium Alloy Connection

Description

Item Numbers

3.4mm

Seating Surface

Hexed Non-Hexed
4.1mm

MPFTC34 MPFTC32 PFTC41 PFTC42 WPFTC51 WPFTC52 WPFTC61 WPFTC62


Seating Surface
10.0

Seating Surface

Hexed Non-Hexed
5.0mm

Seating Surface

Hexed Non-Hexed
6.0mm

Hexed Non-Hexed
All PreFormance Cylinders are packaged with a Titanium Hexed Screw (UNIHT).

All indicated measurements are in millimeters.

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

48

External Hex Connection

Miscellaneous Restorative Products


Screws / Certain Internal Connection

Abutment Screws

Gold-Tite Screw

Titanium Screw

Large Gold-Tite Screw

Large Titanium Screw

Screws Drivers Driver Tips Torque


For Use With:

IUNIHG, IZSHG PHD02N, PHD03N RASH3N, RASH8N 20Ncm

IUNIHT PHD02N, PHD03N RASH3N, RASH8N 20Ncm

ILRGHG PHD02N, PHD03N RASH3N, RASH8N 20Ncm

ILRGHT PHD02N, PHD03N RASH3N, RASH8N 20Ncm

UCLA Abutment, GingiHue Post, GingiHue Post 15, IZSHG - ZiReal Post, Hexed Temporary Cylinder, Provide

Non-Hexed UCLA Abutment, Non-Hexed Temporary Cylinder, CAM StructSURE Precision Milled Bars

Waxing Screws And Try-In Screws

Retaining Screws

Laboratory Screw

Hex (5-pack) Try-In Screw

Gold-Tite Retaining Screw

Screws Drivers Driver Tips


For Use With:

IWSU30 PHD02N, PHD03N RASH3N, RASH8N


Pick-Up and Impression Copings, Implant Level Laboratory Procedures

IUNITS PHD02N, PHD03N RASH3N, RASH8N


Hexed UCLA Abutment, GingiHue Post, GingiHue Post 15, Provide Abutment

Screws Drivers Driver Tips Torque


For Use With:

GSH20, GSH30, GSH70 PHD02N, PHD03N RASH3N, RASH8N 10Ncm


GSH20 - Standard Abutment
6mm(D) X 2mm(H)

Conical Abutment
6mm(D) X 1mm(H)

GSH30 - Standard, Conical and IOL Abutments GSH70 - Standard, Conical and IOL Abutments

49

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Instrumentation
Screws / External Hex Connection

Abutment Screws And Retaining Screws

Gold-Tite Square Abutment Screw

Gold-Tite Hexed Abutment Screw

Titanium Hexed Abutment Screw

Gold-Tite Retaining Screw

Screws Drivers Driver Tips Torque


For Use With:

UNISG PSQD0N, PSQD1N RASQ3N, RASQ8N 3235Ncm

UNIHG PHD02N, PHD03N RASH3N, RASH8N 20Ncm

UNIHT PHD02N, PHD03N RASH3N, RASH8N 20Ncm

GSH20, GSH30, GSH70 PHD02N, PHD03N RASH3N, RASH8N 10Ncm


GSH20 - Standard Abutment
6mm(D) X 2mm(H)

Conical Abutment UCLA Abutment, GingiHue Post, GingiHue Post 15, ZiReal Post, Titanium Cylinder
6mm(D) X 1mm(H)

GSH30 - Standard, Conical and IOL Abutments GSH70 - Standard, Conical and IOL Abutments

Waxing Screws And Try-In Screws

Abutment Waxing Screw/Guide Pin

Laboratory Waxing Screw

Square Try-In Screw (5-pack)

Screws Drivers Driver Tips


For Use With:

WSK10, WSK15, WSK30, MWS15 PHD02N, PHD03N RASH3N, RASH8N


Standard and Conical Abutments

WSU30 PHD02N, PHD03N RASH3N, RASH8N


Implant Level Laboratory Procedures

UNITS, MUNITS PSQD0N, PSQD1N RASQ3N, RASQ8N


UCLA Abutment, GingiHue Post, GingiHue Post 15, ZiReal Post

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

50

Miscellaneous Restorative Products


Mechanical Driver Kits
NCATD0 Contra Angle Torque Driver Kit NPSDK0 Prosthetic Driver Kit

NCATD0C Contra Angle Torque Driver Kit Certain

RTI2035K Torque Indicator Kit

NCATD0
Contra Angle Torque Kit

NCATD0C

NPSDK0

RTI2035K
Torque Indicator Kit Description Item Numbers

Contra Angle Prosthetic Driver Torque Kit Certain Kit

Narrow Posterior Hex Driver, 17mm(L) Narrow Posterior Square Driver, 17mm(L) Contra Angle Torque Driver Body Narrow Right Angle Hex Driver Tip, 24mm(L) Narrow Right Angle Hex Driver Tip, 30mm(L)

PHD02N PSQD0N HTD-C RASH3N RASH8N

Narrow Right Angle Square Driver Tip, 24mm(L) RASQ3N Narrow Right Angle Square Driver Tip, 30mm(L) RASQ8N Right Angle Abutment Driver Tip - Steel Contra Angle Torque Controller, 10Ncm Contra Angle Torque Controller, 20Ncm Contra Angle Torque Controller, 35Ncm Contra Pre-action Handle Prosthetic System Driver Tray Narrow Impression Coping Driver Posterior Abutment Driver, 17mm(L) Standard Abutment Driver, 24mm(L) Posterior Slotted Screw Driver, 17mm(L) Standard Slotted Screw Driver, 24mm(L) RASA3 TD-10 TD-20 TD-35 CATDH PSDT1 ICD00 PAD00 PAD24 PSD00 PSD01

Narrow Standard Slotted Square Driver, 24mm(L) PSQD1N Narrow Standard Hex Driver, 24mm(L) Right Angle Slotted Driver Tip, 24mm(L) Right Angle Slotted Driver Tip, 30mm(L) Restorative Torque Indicator Restorative Torque Tray PHD03N RASD1 RASD6 RTI2035 RTI2035TR

51

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Instrumentation
Drivers And Driver Tips

Small Hex

Large Hex
Tip Driver Tip Driver

Square
Tip

Length

Driver

17mm 24mm 30mm


For Use With:

PHD00N PHD01N N/A

N/A RASH2N RASH7N

PHD02N PHD03N N/A

N/A RASH3N RASH8N

PSQD0N PSQD1N N/A

N/A RASQ3N RASQ8N

External Hex Cover Screws

Healing Abutments, Abutment Screws, Certain Cover Screws and Retaining Screws

Square Gold-Tite Abutment Screws and Square Try-in Screws

O-Ring/Dal-Ro

Abutment
Driver Tip

LOCATOR
Tip Only

Length

Driver

Tip

17mm 24mm 30mm


For Use With:

N/A PAD01 N/A

N/A RAOR1 N/A

PAD00 PAD24 N/A

N/A RASA3 N/A

N/A LOADT4 LOADT9


LOCATOR Abutments

O-Ring Abutments and Dal-Ro Abutments

Conical Abutments, Standard Abutments and IOL Abutments

Impression Coping

.050" Hex
Tip Only

Length

Driver Only

MIDTH

17mm 24mm 30mm


For Use With:

ICD00 N/A N/A


Twist Lock Transfer Impression Copings

N/A RASH4 RASH9


LOCATOR Abutments with LOCATOR Core Tools

Manual Interchangeable Driver Tip Handle

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

52

Miscellaneous Restorative Products


Navigator System Instrumentation Overview

The Navigator System For CT Guided Surgery


The Navigator System offers the instrumentation that clinicians need to transform computer-based planning into practical implant placement with an opportunity for immediate provisionalization. The Navigator System features control of hex-orientation to fabricate and deliver provisional restorations for BIOMET 3i Parallel Walled Certain 3.4, 4.1 and 5mm Implant Platforms, immediately following surgery. This unique hexorientation feature is especially beneficial when immediately loading single tooth cases, cement-retained cases and cases where angulation correction is required. An integral part of the Navigator System is the Navigator Laboratory Kit, which contains easy-to-identify components needed to fabricate a master cast and provisional prosthesis prior to the day of surgery. The Navigator Laboratory Kit provides you with the opportunity to:
Navigator Laboratory Kit

Navigator Surgical Kit

Treat Patients For Immediate-Load Cases Be Part Of A Collaborative Approach To Comprehensive Patient Treatment Embrace Emerging Technology

53

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

SGLKIT Navigator Laboratory Kit

SGLKIT
Laboratory Kit Description Item Numbers

Navigator Laboratory Tray Navigator Certain Analog Mount, 3.4mm(D) x 1(L) Navigator Certain Analog Mount, 3.4mm(D) x 2(L) Navigator Certain Analog Mount, 3.4mm(D) x 3(L) Navigator Certain Analog Mount, 3.4mm(D) x 4(L) Navigator Certain Analog Mount, 4.1mm(D) x 1(L) Navigator Certain Analog Mount, 4.1mm(D) x 2(L) Navigator Certain Analog Mount, 4.1mm(D) x 3(L) Navigator Certain Analog Mount, 4.1mm(D) x 4(L) Navigator Certain Analog Mount, 5mm(D) x 1(L) Navigator Certain Analog Mount, 5mm(D) x 2(L) Navigator Certain Analog Mount, 5mm(D) x 3(L) Navigator Certain Analog Mount, 5mm(D) x 4(L)

SGLTRAY MSGIAM1 MSGIAM2 MSGIAM3 MSGIAM4 SGIAM41 SGIAM42 SGIAM43 SGIAM44 SGIAM51 SGIAM52 SGIAM53 SGIAM54

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

54

Miscellaneous Restorative Products


Laboratory Tools
Lapping Tool For Castable UCLA Abutment With Guide
RH600 IRH600

Reamer With Handle

PPMC1 Polishing Protector, 3.4mm(D) Conical Abutment PPCA3

Certain
IMLT150 ILT150 ILT150 MLT150 LT150 WLT10

3.4mm(D) 4.1mm(D) 5.0mm(D)

RH600R

4.1mm(D) 5.0mm(D)
WCPP6

Reamer Only 6.0mm(D)

Polishing Protector, UCLA Abutment

Laboratory Abutment Holder

PPSA3 Polishing Protector, 4.1mm(D) Standard Abutment

IPPMM1 IPPIA3 IPPIA5 IPPIA6

PPMM1 PPIA3 WPP50 WPP60

3.4mm(D) 4.1mm(D) 5.0mm(D) 6.0mm(D)

ILTAH57 ILTAH57 ILTAH57 ILTAH57

LTAH5 LTAH7 LTAH7 LTAH7

3.4mm(D) 4.1mm(D) 5.0mm(D) 6.0mm(D)

IQSA01

Certain QuickSeat Activator Tool

Restorative Products
Miscellaneous Items
TMP80

Tissue Measuring Post

SRT10

Screw Removal Kit

8.0 6.0 4.0 2.0

SRT05

SRT01

SRT02

SRT03

SRT04

AG900

Prosthetic Angle Guide Kit


15

ISRT10

Certain Screw Removal Kit

25

ISRT05

35

ISRT01

ISRT06

ISRT07

IWSU30

55

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

Professional Development Products


Tools For The Art Of Business Building

BIOMET 3i has a dedicated Professional Development Team and a comprehensive Practice Enhancement Portfolio. This portfolio includes tools for marketing, professional education and patient awareness education. Current available materials include (but are not limited to) the following:
Description Item Numbers

BIOMET 3i IDS Creating & Driving Your Own Study Club Guidebook 3x Model of GingiHue Post 4mm(D) x 5mm(D) x 2mm(H) with Square Screw 3x Model of OSSEOTITE Implant 4mm(D) x 13mm(L) 3x Model of OSSEOTITE Tapered Implant

ART895 APPGMOD1 OSSMOD1 NTMOD1

3x Model Set with OSSEOTITE Tapered Certain Implant & GingiHue Post INTMODSET Patient Awareness and Education Kit Patient Care Card (25pk) Patient Ed Flip Chart Patient Ed Folio with DVD Patient Ed Brochure - Bone Loss (25pk) Patient Ed Brochure - Single Tooth (25pk) Patient Ed Brochure - Multiple Teeth (25pk) Patient Ed Brochure - Implant Retained, Bar (25pk) Patient Ed Brochure - Implant Retained, Fixed (25pk) Patient Ed Brochure - Implant Retained, LOCATOR (25pk) Patient Ed Brochure - Immediate Teeth Replacement, DIEM (25pk) Patient Ed Brochure - Spanish Version (Bone Loss) Patient Ed Brochure - Spanish Version Patient Ed DVD - Multilingual Version Patient Ed Model - LOCATOR Patient Ed Model - Single/Multiple Teeth Patient Ed Poster Wrench for Tightening Model Screws ART933 ART930 ART943 ART884 ART885 ART886 ART887 ART890 ART888 ART889 ART929 ART957S ART958S ART951EUR PEMODLOC PEMODSM ART962 MODWRENCH

Some products may not be available outside of the United States. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.

56

Index
Cat.#
AB200 AB300 AB400 AB550 AB700 AC4217 AC4225 AC4417 AC4425 AG900 APP452G APP454G APP462G APP464G APP472G APP474G

Description
STANDARD ABUTMENT 4.1MM(D) X 2MM(H) STANDARD ABUTMENT 4.1MM(D) X 3MM(H) STANDARD ABUTMENT 4.1MM(D) X 4MM(H) STANDARD ABUTMENT 4.1MM(D) X 5.5MM(H) STANDARD ABUTMENT 4.1MM(D) X 7MM(H) PRE-ANGLED 17 CONICAL ABUTMENT 4.1MM(D) X 2MM(H) PRE-ANGLED 25 CONICAL ABUTMENT 4.1MM(D) X 2MM(H) PRE-ANGLED 17 CONICAL ABUTMENT 4.1MM(D) X 4MM(H) PRE-ANGLED 25 CONICAL ABUTMENT 4.1MM(D) X 4MM(H) PROSTHETIC ANGLE GUIDE KIT (9PC SET) GINGIHUE POST 4.1MM(D) X 5MM(P) X 2MM(H) GINGIHUE POST 4.1MM(D) X 5MM(P) X 4MM(H) GINGIHUE POST 4.1MM(D) X 6MM(P) X 2MM(H) GINGIHUE POST 4.1MM(D) X 6MM(P) X 4MM(H) GINGIHUE POST 4.1MM(D) X 7.5MM(P) X 2MM(H) GINGIHUE POST 4.1MM(D) X 7.5MM(P) X 4MM(H)

Page#
39 39 39 39 39 35 35 35 35 55 25 25 25 25 25 25 56 56 56 56 56 56 56 56 56

Cat.#
CS260 CS270 CSQ06 CSQ07 CSQI7 CSQN6 CSQN7 DRAF DRCS1 DRFAT1 DRH20 DRH40 DRH60 DRLAU DRTH GSH20 GSH30 GSH70 GUCA1C GUCA2C HTD-C IAB200 IAB300 IAB400 IAB550 IAB700 IAC4217 IAC4225 IAC4417 IAC4425 IAPP452G IAPP454G IAPP462G IAPP464G IAPP472G IAPP474G ICA001 ICA002 ICA003 ICA004 ICA055 ICAP454 ICAP464 ICD00 IGUCA1C IGUCA2C IGUCA2T IIC12 IIC45 IIC46 IIC47

Description
CONICAL EP HEALING CAP 4.1MM & 5MM(D) X 6MM(P) CONICAL EP HEALING CAP 4.1MM & 5MM(D) X 7.5MM(P)

Page#
16,36 16,36

CONICAL EP PICK-UP COPING (NON-HEXED) 4.1 & 5MM(D) X 6MM(P) 16,36 CONICAL EP PICK-UP COPING (NON-HEXED) 4.1 & 5MM(D) X 7.5MM(P) 16,36

CONICAL EP PICK-UP COPING (NON-HEXED) 4.1 & 5MM(D) X 5MM(P) 16,36 CONICAL EP PICK-UP COPING (HEXED) 4.1 & 5MM(D) X 6MM(P) CONICAL EP PICK-UP COPING (HEXED) 4.1 & 5MM(D) X 7.5MM(P) DAL-RO REPLACEMENT FEMALE DAL-RO CASTABLE SYSTEM DAL-RO FEMALE ATTACHMENT TOOL DAL-RO ABUTMENT 4.1MM(D) X 2MM(H) DAL-RO ABUTMENT 4.1MM(D) X 4MM(H) DAL-RO ABUTMENT 4.1MM(D) X 6MM(H) DAL-RO UNIVERSAL LABORATORY ANALOG DAL-RO HOUSING/FEMALE ASSEMBLY GOLD-TITE (HEXED) RETAINING SCREW 2MM 16,36 16,36 46 46 46 45 45 45 46 46 16,20,36,40,49,50

APPGMOD1 3X MODEL OF GINGIHUE POST 4MM(D) X 5MM(D) X 2MM(H) WITH SQUARE SCREW ART884 ART885 ART886 ART887 ART888 ART889 ART890 ART895 ART929 ART930 ART933 ART943 PATIENT ED FOLIO WITH DVD PATIENT ED BROCHURE - BONE LOSS (25PK) PATIENT ED BROCHURE - SINGLE TOOTH (25PK) PATIENT ED BROCHURE - MULTIPLE TEETH (25PK) PATIENT ED BROCHURE - IMPLANT RETAINED, FIXED (25PK) PATIENT ED BROCHURE - IMPLANT RETAINED, LOCATOR (25PK) PATIENT ED BROCHURE - IMPLANT RETAINED, BAR (25PK) BIOMET 3i IDS CREATING & DRIVING YOUR OWN STUDY CLUB GUIDEBOOK

GOLD-TITE (HEXED) RETAINING SCREW 3MM 14,16,18,20,34,36,38,40,49,50 GOLD-TITE (HEXED) RETAINING SCREW 7MM 14,16,18,20,34,36,38,40,49,50 UCLA GOLD (HEXED) ABUTMENT CYLINDER 4.1MM(D) UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 4.1MM(D) CONTRA ANGLE TORQUE DRIVER BODY CERTAIN STANDARD ABUTMENT 4.1MM(D) X 2MM(H) CERTAIN STANDARD ABUTMENT 4.1MM(D) X 3MM(H) CERTAIN STANDARD ABUTMENT 4.1MM(D) X 4MM(H) CERTAIN STANDARD ABUTMENT 4.1MM(D) X 5.5MM(H) CERTAIN STANDARD ABUTMENT 4.1MM(D) X 7MM(H) CERTAIN PRE-ANGLED 17 CONICAL ABUTMENT 4.1MM(D) X 2MM(H) CERTAIN PRE-ANGLED 25 CONICAL ABUTMENT 4.1MM(D) X 2MM(H) CERTAIN PRE-ANGLED 17 CONICAL ABUTMENT 4.1MM(D) X 4MM(H) CERTAIN PRE-ANGLED 25 CONICAL ABUTMENT 4.1MM(D) X 4MM(H) CERTAIN GINGIHUE POST 4.1MM(D) X 5MM(P) X 2MM(H) CERTAIN GINGIHUE POST 4.1MM(D) X 5MM(P) X 4MM(H) CERTAIN GINGIHUE POST 4.1MM(D) X 6MM(P) X 2MM(H) CERTAIN GINGIHUE POST 4.1MM(D) X 6MM(P) X 4MM(H) CERTAIN GINGIHUE POST 4.1MM(D) X 7.5MM(P) X 2MM(H) CERTAIN GINGIHUE POST 4.1MM(D) X 7.5MM(P) X 4MM(H) CERTAIN CONICAL ABUTMENT 4.1MM(D) X 1MM(H) CERTAIN CONICAL ABUTMENT 4.1MM(D) X 2MM(H) CERTAIN CONICAL ABUTMENT 4.1MM(D) X 3MM(H) CERTAIN CONICAL ABUTMENT 4.1MM(D) X 4MM(H) CERTAIN CONICAL ABUTMENT 4.1MM(D) X 5.5MM(H) CERTAIN ZIREAL POST 4.1MM(D) X 5MM(P) X 4MM(H) CERTAIN ZIREAL POST 4.1MM(D) X 6MM(P) X 4MM(H) NARROW IMPRESSION COPING DRIVER 3.4MM(D) X 3.8MM(P) X 3MM(H)4 X MM(D) X 8.5MM(L) CERTAIN UCLA GOLD HEXED ABUTMENT CYLINDER 4.1MM(D) CERTAIN UCLA GOLD NON-HEXED ABUTMENT CYLINDER 4.1MM(D) CERTAIN UCLA GOLD NON-HEXED ABUTMENT CYLINDER 4.1MM(D) IMPLANT EP PICK-UP COPING 4.1MM(D) X 5MM(P) IMPLANT EP TWIST LOCK COPING 4.1MM(D) X 5MM(P) IMPLANT EP TWIST LOCK COPING 4.1MM(D) X 6MM(P) IMPLANT EP TWIST LOCK COPING 4.1MM(D) X 7.5MM(P) 29,31 31 51 19 19 19 19 19 15 15 15 15 5 5 5 5 5 5 15 15 15 15 15 7 7 51,52 9,11 11 11

PATIENT ED BROCHURE - IMMEDIATE TEETH REPLACEMENT, DIEM (25PK) 56 PATIENT CARE CARD (25PK) PATIENT AWARENESS AND EDUCATION KIT PATIENT ED FLIP CHART 56 56 56 56 56 56 56 16,36 16,36 16,36 27 27 51 16,36 20,40 16,36 16,36 16,36 16,36 16,36 16,36 16,36 16,36 16,36 16,36

ART951EUR PATIENT ED DVD - MULTILINGUAL VERSION ART957S ART958S ART962 CACC5 CAGC5 CAGC6 CAP454 CAP464 CATDH CC300 CGC30 CIC55 CIC56 CIC57 CLA20 CNC30 CNRC5 CNRG5 CNRG6 CNRIC CS250 PATIENT ED BROCHURE - SPANISH VERSION (BONE LOSS) PATIENT ED BROCHURE - SPANISH VERSION PATIENT ED POSTER CONICAL CASTABLE CYLINDER (NON-HEXED) 4.1MM & 5MM(D) CONICAL GOLD CYLINDER (NON-HEXED) 4.1MM & 5MM(D) CONICAL GOLD CYLINDER (NON-HEXED) 6MM(D) ZIREAL POST 4.1MM(D) X 5MM(P) X 4MM(H) ZIREAL POST 4.1MM(D) X 6MM(P) X 4MM(H) CONTRA PRE-ACTION HANDLE CONICAL TEMPORARY CYLINDER (NON-HEXED) 4.1 & 5MM(D) CHAMFERED GOLD CYLINDER FOR STANDARD ABUTMENT CONICAL EP TWIST LOCK COPING 4.1 & 5MM(D) X 5MM(P) CONICAL EP TWIST LOCK COPING 4.1 & 5MM(D) X 6MM(P) CONICAL EP TWIST LOCK COPING 4.1 & 5MM(D) X 7.5MM(P) CONICAL ABUTMENT LAB ANALOG 4.1 & 5MM(D) CONICAL TEMPORARY CYLINDER (HEXED) 4.1 & 5MM(D) CONICAL CASTABLE CYLINDER (HEXED) 4.1MM & 5MM(D) CONICAL GOLD CYLINDER (HEXED) 4.1 & 5MM(D) CONICAL GOLD CYLINDER (HEXED) 6MM(D) CONICAL EP PICK-UP COPING (HEXED) 4.1 & 5MM(D) X 5MM(P) CONICAL EP HEALING CAP 4.1MM & 5MM(D) X 5MM(P)

26,28,30,32 26,28,30,32 26,28,30,32 26,28,30,32

Index
Cat.#
IIC60 IIC75 IIIC12 IIIC41 IIIC42 IIIC44 IIIC45 IIIC46 IIIC47 IIIC60 IIIC75 IILA20 IILAW5 IILAW6 IIOL20S IIOL30S IIOL40S IIOL55S IIOL70S IITCS41 IITCS42 ILA20 ILAW5 ILAW6 ILOA001 ILOA002 ILOA003 ILOA004 ILOA005 ILOA006 ILRGHG ILRGHT ILT150 ILTAH57 IMAP32G IMAP34G IMCA31 IMCA32 IMCA33 IMCA34 IMIC30 IMIC33 IMLOA001 IMLOA002 IMLOA003 IMLOA004 IMLOA005 IMLOA006 IMLT150 IMMILA

Description
IMPLANT EP PICK-UP COPING 4.1MM(D) X 6MM(P) IMPLANT EP PICK-UP COPING 4.1MM(D) X 7.5MM(P) CERTAIN EP PICK-UP COPING 4.1MM(D) X 5MM(P) CERTAIN EP PICK-UP COPING 4.1MM(D) X 4.1MM(P)

Page#
26,28,30,32 26,28,30,32 6,8,10,12 6,8,10,12

Cat.#
IMMTCS1 IMPAP32G IMPAP34G

Description
CERTAIN TEMPORARY HEXED CYLINDER 3.4MM(D) W/HEXED SCREW CERTAIN GINGIHUE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 4MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 4MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 6MM(H) CERTAIN PREFORMANCE POST 3.4MM(D) X 3.8MM(P) X 4MM(H) CERTAIN PREFORMANCE POST 3.4MM(D) X 3.8MM(P) X 6MM(H) CERTAIN PREFORMANCE TEMPORARY CYLINDER 3.4MM (NON-HEXED) CERTAIN PREFORMANCE TEMPORARY CYLINDER 3.4MM (HEXED)

Page#
12 5 5 23 23 23 23 12,24 12,24

CERTAIN EP PICK-UP COPING (NON-HEXED) 4.1MM(D) X 4.1MM(P) 6,8,10,12 CERTAIN EP TWIST LOCK COPING 4.1MM(D) X 4.1MM(P) CERTAIN EP TWIST LOCK COPING 4.1MM(D) X 5MM(P) CERTAIN EP TWIST LOCK COPING 4.1MM(D) X 6MM(P) CERTAIN EP TWIST LOCK COPING 4.1MM(D) X 7.5MM(P) CERTAIN EP PICK-UP COPING 4.1MM(D) X 6MM(P) CERTAIN EP PICK-UP COPING 4.1MM(D) X 7.5MM(P) CERTAIN IMPLANT LAB ANALOG 4.1MM(D) CERTAIN IMPLANT LAB ANALOG 5MM(D) CERTAIN IMPLANT LAB ANALOG 6MM(D) CERTAIN IOL ABUTMENT 2MM(H) CERTAIN IOL ABUTMENT 3MM(H) CERTAIN IOL ABUTMENT 4MM(H) CERTAIN IOL ABUTMENT 5.5MM(H) CERTAIN IOL ABUTMENT 7MM(H) 6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,10,12 13,17 13,17 13,17 13,17 13,17 IMUCC2C IMUCC2T IMUCG1C IMUCG2C IMUCG2T IMPFTC34 IMPFP36 IMPFTC32 IMPFP34 IMPAPF36 IMPAPF34

CERTAIN UCLA CASTABLE NON-HEXED ABUTMENT CYLINDER 3.4MM(D)11 CERTAIN UCLA CASTABLE NON-HEXED ABUTMENT CYLINDER 3.4MM(D)11 CERTAIN UCLA GOLD HEXED ABUTMENT CYLINDER 3.4MM(D) CERTAIN UCLA GOLD NON-HEXED ABUTMENT CYLINDER 3.4MM(D) CERTAIN UCLA GOLD NON-HEXED ABUTMENT CYLINDER 3.4MM(D) W/TI SCREW 9,11 11 11 56 33,37 33,37 33,37 33,37 33,37 18,38 14,18,34,38 14,18,34,38 14,18,34,38 14,18,34,38 14,18,34,38 14,18,34,38 14,18,34,38 3 3 3 3 3 3 3 3 3

CERTAIN TEMPORARY (HEXED) CYLINDER 4.1MM(D) W/HEXED SCREW 12 CERTAIN TEMPORARY (NON-HEXED) CYLINDER 4.1MM(D) W/LARGE DIA. SCREW IMPLANT LAB ANALOG 4.1MM(D) IMPLANT LAB ANALOG 5MM(D) IMPLANT LAB ANALOG 6MM(D) CERTAIN LOCATOR ABUTMENT 4.1MM(D) X 1MM(H) CERTAIN LOCATOR ABUTMENT 4.1MM(D) X 2MM(H) CERTAIN LOCATOR ABUTMENT 4.1MM(D) X 3MM(H) CERTAIN LOCATOR ABUTMENT 4.1MM(D) X 4MM(H) CERTAIN LOCATOR ABUTMENT 4.1MM(D) X 5MM(H) CERTAIN LOCATOR ABUTMENT 4.1MM(D) X 6MM(H) CERTAIN GOLD-TITE (HEXED) LARGE SCREW CERTAIN TITANIUM (HEXED) LARGE SCREW CERTAIN LAPPING TOOL FOR CASTABLE UCLA ABUTMENT W/GUIDE 4MM(D) CERTAIN LABORATORY ABUTMENT HOLDER FOR ALL CERTAIN PLATFORMS CERTAIN GINGIHUE POST 3.4MM(D) X 3.8MM(P) X 2MM(H) CERTAIN GINGIHUE POST 3.4MM(D) X 3.8MM(P) X 4MM(H) CERTAIN CONICAL ABUTMENT 3.4MM(D) X 1MM(H) CERTAIN CONICAL ABUTMENT 3.4MM(D) X 2MM(H) CERTAIN CONICAL ABUTMENT 3.4MM(D) X 3MM(H) CERTAIN CONICAL ABUTMENT 3.4MM(D) X 4MM(H) CERTAIN EP PICK-UP COPING 3.4MM(D) X 3.4MM(P) CERTAIN EP PICK-UP COPING 3.4MM(D) X 3.8MM(P) CERTAIN LOCATOR ABUTMENT 3.4MM(D) X 1MM(H) CERTAIN LOCATOR ABUTMENT 3.4MM(D) X 2MM(H) CERTAIN LOCATOR ABUTMENT 3.4MM(D) X 3MM(H) CERTAIN LOCATOR ABUTMENT 3.4MM(D) X 4MM(H) CERTAIN LOCATOR ABUTMENT 3.4MM(D) X 5MM(H) CERTAIN LOCATOR ABUTMENT 3.4MM(D) X 6MM(H) CERTAIN LAPPING TOOL FOR CASTABLE UCLA ABUTMENT W/GUIDE, 3.4MM(D) CERTAIN IMPLANT LAB ANALOG 3.4MM(D) 12 26,28,30,32 26,28,30,32

INTMODSET 3X MODEL SET WITH OSSEOTITE TAPERED CERTAIN IMPLANT AND GINGIHUE POST IOL20T IOL ABUTMENT 2MM(H) IOL ABUTMENT 3MM(H) IOL ABUTMENT 4MM(H) IOL ABUTMENT 5.5MM(H) IOL ABUTMENT 7MM(H) IOL DISTAL EXTENSION IOL GOLD CYLINDER IOL HEALING CAP IOL STRAIGHT LAB ANALOG IOL PICK-UP IMPRESSION COPING IOL POLISHING PROTECTOR IOL TWIST LOCK IMPRESSION COPING IOL TRANSFER IMPRESSION COPING PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 1MM(COLLAR) X 4MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 1MM(COLLAR) X 5.5MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 2MM(COLLAR) X 4MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 2MM(COLLAR) X 5.5MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 3MM(COLLAR) X 4MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 3MM(COLLAR) X 5.5MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 4MM(COLLAR) X 4MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 4.1MM(PLATFORM) X 4MM(COLLAR) X 5.5MM(POST) X 4.8MM(PROFILE) PROVIDE ABUTMENT - 5MM(PLATFORM) X 1MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE)

26,30,32 IOL30T 21 IOL40T 21 IOL55T 21 IOL70T 21 IOLDE 21 IOLGC 21 IOLHC 12,49 IOLLAS 12,49 IOLPIC 55 IOLPP 6,8,10,12,55 5 5 15 15 IPA4240 15 15 6,10,12 6,10,12 21 21 21 21 21 21 55 6,10,12 IPA5140 IPA4440 IPA4455 IPA4355 IPA4340 IPA4255 IPA4155 IOLTC IOLTIC IPA4140

Index
Cat.#
IPA5155 IPA5240 IPA5255 IPA5340 IPA5355

Description
PROVIDE ABUTMENT - 5MM(PLATFORM) X 1MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 5MM(PLATFORM) X 2MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 5MM(PLATFORM) X 2MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 5MM(PLATFORM) X 3MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 5MM(PLATFORM) X 3MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE)

Page#
3 3 3 3 3

Cat.#
IPAP674G IPAPF454 IPAPF456 IPAPF554 IPAPF556 IPAPF664 IPAPF666 IPFP454 IPFP456

Description
CERTAIN GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 7.5MM(P) X 4MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 4MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 6MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 4MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 6MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 4MM(H) CERTAIN PREFORMANCE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 6MM(H) CERTAIN PREFORMANCE POST 4.1MM(D) X 5MM(P) X 4MM(H) CERTAIN PREFORMANCE POST 4.1MM(D) X 5MM(P) X 6MM(H)

Page#
5 23 23 23 23 23 23 23 23 12,24

IPA5440 IPA5455 IPA6140 IPA6155 IPA6240 IPA6255 IPA6340 IPA6355

PROVIDE ABUTMENT - 5MM(PLATFORM) X 4MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 5MM(PLATFORM) X 4MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 1MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 1MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 2MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 2MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 3MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 3MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE)

3 3 3 3 3 3 3 3

IPFTC41 IPFTC42 IPPIA3 IPPIA5 IPPIA6 IPPMM1 IQSA01 IRH600 ISRT01

CERTAIN PREFORMANCE TEMPORARY CYLINDER 4.1MM (HEXED)

CERTAIN PREFORMANCE TEMPORARY CYLINDER 4.1MM (NON-HEXED) 12,24 CERTAIN UCLA POLISHING PROTECTOR 4.1MM(D) CERTAIN UCLA POLISHING PROTECTOR 5MM(D) CERTAIN UCLA POLISHING PROTECTOR 6MM(D) CERTAIN UCLA POLISHING PROTECTOR 3.4MM(D) CERTAIN QUICKSEAT ACTIVATOR TOOL CERTAIN REAMER WITH HANDLE CERTAIN HAND TAP CERTAIN GUIDE HANDLE CERTAIN SCREW REMOVAL TOOL MANUAL REVERSING TOOL CERTAIN SCREW REMOVAL KIT TEMPORARY (HEXED) IMPLANT CYLINDER 4.1MM(D) W/RETENTION AND HEXED SCREW TEMPORARY (NON-HEXED) IMPLANT CYLINDER 4.1MM(D) 55 55 55 55 6,8,10,11,12 55 55 55 55 55 55 32 32

IPA6440 IPA6455 IPAP452G IPAP454G IPAP462G IPAP464G IPAP472G IPAP474G IPAP552G IPAP554G IPAP562G IPAP564G IPAP572G IPAP574G IPAP662G IPAP664G IPAP672G

PROVIDE ABUTMENT - 6MM(PLATFORM) X 4MM(COLLAR) X 4MM(POST) X 6.5MM(PROFILE) PROVIDE ABUTMENT - 6MM(PLATFORM) X 4MM(COLLAR) X 5.5MM(POST) X 6.5MM(PROFILE) CERTAIN GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 6MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 6MM(P) X 4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 7.5MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 7.5MM(P) X4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 6MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 6MM(P) X 4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 7.5MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 7.5MM(P) X 4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 2MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 4MM(H) CERTAIN GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 7.5MM(P) X 2MM(H)

3 3

ISRT05 ISRT06 ISRT07

5 5

ISRT10 ITCS41 ITCS42

5 5 5

IUNAB2C IUNAB2T IUNIHG IUNIHT IUNITS

CERTAIN UCLA CASTABLE NON-HEXED ABUTMENT CYLINDER 4.1MM(D) 11 CERTAIN UCLA CASTABLE NON-HEXED ABUTMENT CYLINDER 4.1MM(D) 11 CERTAIN GOLD-TITE (HEXED) SCREW CERTAIN TITANIUM (HEXED) SCREW CERTAIN HEX TRY-IN SCREW (5PK) 3.4, 4.1, 5, 6MM(D) CERTAIN CONICAL ABUTMENT 5MM(D) X 1MM(H) CERTAIN CONICAL ABUTMENT 5MM(D) X 2MM(H) CERTAIN CONICAL ABUTMENT 5MM(D) X 3MM(H) CERTAIN CONICAL ABUTMENT 5MM(D) X 4MM(H) CERTAIN CONICAL ABUTMENT 5MM(D) X 5.5MM(H) CERTAIN CONICAL ABUTMENT 6MM(D) X 1MM(H) CERTAIN CONICAL ABUTMENT 6MM(D) X 2MM(H) CERTAIN CONICAL ABUTMENT 6MM(D) X 3MM(H) CERTAIN CONICAL ABUTMENT 6MM(D) X 4MM(H) CERTAIN CONICAL ABUTMENT 6MM(D) X 5.5MM(H) CERTAIN ZIREAL POST 5MM(D) X 6MM(P) X 4MM(H) CERTAIN ZIREAL POST 5MM(D) X 7.5MM(P) X 4MM(H) CERTAIN UCLA GOLD (HEXED) ABUTMENT CYLINDER 5MM(D) CERTAIN UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 5MM(D) CERTAIN UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 5MM(D) CERTAIN UCLA GOLD (HEXED) ABUTMENT CYLINDER 6MM(D) CERTAIN UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 6MM(D) CERTAIN UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 6MM(D) 4,6,10,12,49 4,6,10,12,49 6,10,12,49 15 15 15 15 15 15 15 15 15 15 7 7 9,11 11 11 9,11 11 11

5 5 5 5 5 5 5 5 5

IWCA51 IWCA52 IWCA53 IWCA54 IWCA55 IWCA61 IWCA62 IWCA63 IWCA64 IWCA65 IWCAP564 IWCAP574 IWGA51C IWGA52C IWGA52T IWGA61C

IWGA62C IWGA62T

Index
Cat.#
IWIP50 IWIP55 IWIP56 IWIP57 IWIP60 IWIP66 IWIP67 IWIT50 IWIT55 IWIT56 IWIT57 IWIT60 IWIT66 IWIT67 IWPC52C IWPC52T IWPC62C IWPC62T IWPFP554 IWPFP556 IWPFP664 IWPFP666 IWPFTC51 IWPFTC52 IWPFTC61 IWPFTC62

Description
CERTAIN STRAIGHT PICK-UP COPING 5MM(D) X 5MM(P) CERTAIN EP PICK-UP COPING 5MM(D) X 5.6MM(P) CERTAIN EP PICK-UP COPING 5MM(D) X 6MM(P) CERTAIN EP PICK-UP COPING 5MM(D) X 7.5MM(P) CERTAIN STRAIGHT PICK-UP COPING 6MM(D) X 6MM(P) CERTAIN EP PICK-UP COPING 6MM(D) X 6.6MM(P) CERTAIN EP PICK-UP COPING 6MM(D) X 7.5MM(P) CERTAIN STRAIGHT TRANSFER COPING 5MM(D) X 5MM(P) CERTAIN EP TWIST LOCK COPING 5MM(D) X 5.6MM(P) CERTAIN EP TWIST LOCK COPING 5MM(D) X 6MM(P) CERTAIN EP TWIST LOCK COPING 5MM(D) X 7.5MM(P) CERTAIN STRAIGHT TRANSFER COPING 6MM(D) X 6MM(P) CERTAIN EP TWIST LOCK COPING 6MM(D) X 6.6MM(P) CERTAIN EP TWIST LOCK COPING 6MM(D) X 7.5MM(P)

Page#
6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,10,12 6,10,12 6,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,8,10,12 6,10,12 6,10,12 6,10,12

Cat.#
LOA001 LOA002 LOA003 LOA004 LOA005 LOA006 LOAB LOAD LOADT4 LOADT9 LOAH LOAT LORHK LT150 LTAH5 LTAH7 MAP32G MAP34G MCA31 MCA32 MCA33 MCA34 MCAG1 MCAG2 MCTC1 MCTC2 MEC33

Description
LOCATOR ABUTMENT 4.1MM(D) X 1MM(H) LOCATOR ABUTMENT 4.1MM(D) X 2MM(H) LOCATOR ABUTMENT 4.1MM(D) X 3MM(H) LOCATOR ABUTMENT 4.1MM(D) X 4MM(H) LOCATOR ABUTMENT 4.1MM(D) X 5MM(H) LOCATOR ABUTMENT 4.1MM(D) X 6MM(H) LOCATOR BAR ATTACHMENT LOCATOR BAR ATTACHMENT DRILL LOCATOR ABUTMENT DRIVER TIP 24MM(L) LOCATOR ABUTMENT DRIVER TIP 30MM(L) LOCATOR REPLACEMENT HOUSING LOCATOR BAR ATTACHMENT TAP LOCATOR REPLACEMENT HOUSING KIT

Page#
41 41 41 41 41 41 20,22,40,42 20,22,40,42 22,42,52 22,42,52 22,42 20,22,40,42 22,42 55

LAPPING TOOL FOR CASTABLE UCLA ABUTMENT W/GUIDE, 4MM(D) LABORATORY ABUTMENT HOLDER FOR 3.4MM(D) LABORATORY HOLDER FOR 4.1, 5, 6MM(D) GINGIHUE POST 3.4MM(D) X 3.8MM(P) X 2MM(H) GINGIHUE POST 3.4MM(D) X 3.8MM(P) X 4MM(H) CONICAL ABUTMENT 3.4MM(D) X 1MM(H) CONICAL ABUTMENT 3.4MM(D) X 2MM(H) CONICAL ABUTMENT 3.4MM(D) X 3MM(H) CONICAL ABUTMENT 3.4MM(D) X 4MM(H) CONICAL GOLD CYLINDER (HEXED) 3.4MM(D) CONICAL GOLD CYLINDER (NON-HEXED) 3.4MM(D) CONICAL ABUTMENT TEMPORARY CYLINDER (HEXED) 3.4MM(D) CONICAL ABUTMENT TEMPORARY 3.4MM(D) CYLINDER (NON-HEXED) CONICAL ABUTMENT PICK-UP COPING 3.4MM(D) CONICAL HEALING CAP 3.4MM(D) PICK UP IMPRESSION COPING 3.4MM(D) MANUAL INTERCHANGEABLE DRIVER TIP HANDLE LOCATOR ABUTMENT 3.4MM(D) X 1MM(H) LOCATOR ABUTMENT 3.4MM(D) X 2MM(H) LOCATOR ABUTMENT 3.4MM(D) X 3MM(H) LOCATOR ABUTMENT 3.4MM(D) X 4MM(H) LOCATOR ABUTMENT 3.4MM(D) X 5MM(H) LOCATOR ABUTMENT 3.4MM(D) X 6MM(H) LAPPING TOOL FOR CASTABLE UCLA ABUTMENT W/GUIDE, 3.4MM(D) CONICAL LAB ANALOG 3.4MM(D) LAB ANALOG 3.4MM(D) TEMPORARY (HEXED) CYLINDER 3.4MM(D) W/RETENTION AND HEXED SCREW

CERTAIN UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER 5MM(D) 11 CERTAIN UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER 5MM(D) 11 CERTAIN UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER 6MM(D) 11 CERTAIN UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER 6MM(D) 11 CERTAIN PREFORMANCE POST 5MM(D) X 5MM(P) X 4MM(H) CERTAIN PREFORMANCE POST 5MM(D) X 5MM(P) X 6MM(H) CERTAIN PREFORMANCE POST 6MM(D) X 6MM(P) X 4MM(H) CERTAIN PREFORMANCE POST 6MM(D) X 6MM(P) X 6MM(H) CERTAIN PREFORMANCE TEMPORARY CYLINDER 5MM (HEXED) 23 23 23 23 12,24

26,30,32,55 26,28,30,32,55 25 25 35 35 35 35 16,36 16,36 16,36 16,36 16,36 16,36 26,30,32 52 41 41 41 41 41 41 55 16,36 26,30,32 32 56 25 25 47 47 47 47 32

CERTAIN PREFORMANCE TEMPORARY CYLINDER 5MM (NON-HEXED) 12,24 CERTAIN PREFORMANCE TEMPORARY CYLINDER 6MM (HEXED) 12,24

CERTAIN PREFORMANCE TEMPORARY CYLINDER 6MM (NON-HEXED) 12,24 5 5 5 MHC33 5 MIC33 5 MIDTH 5 MLOA001 5 MLOA002 5 MLOA003 5 MLOA004 5 MLOA005 49,55 MLOA006 12 MLT150 12 MMCLA 12 MMILA 12 MMTCS1 8

IWPP552G CERTAIN GINGIHUE POST 5MM(D) X 5MM(P) X 2MM(H) IWPP554G CERTAIN GINGIHUE POST 5MM(D) X 5MM(P) X 4MM(H) IWPP562G CERTAIN GINGIHUE POST 5MM(D) X 6MM(P) X 2MM(H) IWPP564G CERTAIN GINGIHUE POST 5MM(D) X 6MM(P) X 4MM(H) IWPP572G CERTAIN GINGIHUE POST 5MM(D) X 7.5MM(P) X 2MM(H) IWPP574G CERTAIN GINGIHUE POST 5MM(D) X 7.5MM(P) X 4MM(H) IWPP662G CERTAIN GINGIHUE POST 6MM(D) X 6MM(P) X 2MM(H) IWPP664G CERTAIN GINGIHUE POST 6MM(D) X 6MM(P) X 4MM(H) IWPP672G CERTAIN GINGIHUE POST 6MM(D) X 7.5MM(P) X 2MM(H) IWPP674G CERTAIN GINGIHUE POST 6MM(D) X 7.5MM(P) X 4MM(H) IWSU30 IWTCS51 IWTCS52 IWTCS61 IWTCS62 IZIRTS IZSHG LAELM LAERM LAIC1 LALA1 LARMS LCTDR1 LELARM LLRMS CERTAIN WAXING SCREW/GUIDE PIN

CERTAIN TEMPORARY (HEXED) CYLINDER 5MM(D) W/HEXED SCREW CERTAIN TEMPORARY (NON-HEXED) CYLINDER 5MM(D) W/LARGE DIA. SCREW CERTAIN TEMPORARY (HEXED) CYLINDER 6MM(D) W/HEXED SCREW CERTAIN TEMPORARY (NON-HEXED) CYLINDER 6MM(D) W/LARGE DIA. SCREW CERTAIN HEX TRY-IN SCREW CERTAIN ZIREAL GOLD-TITE (HEXED) SCREW LOCATOR EXTRA LIGHT RETENTION MALES (4PK) LOCATOR EXTENDED RANGE MALES - GREEN, 4LBS/1800G (4PK) LOCATOR ABUTMENT IMPRESSION COPING LOCATOR ABUTMENT LAB ANALOG LOCATOR REPLACEMENT MALES - WHITE, 5LBS/2250G (4PK) LOCATOR CORE TOOL/ABUTMENT DRIVER EXTRA LIGHT RETENTION EXTENDED RANGE MALES RED, 1.5LBS/680G LOCATOR LIGHT RETENTION REPLACEMENT MALES PINK, 3LBS/1350G (4PK)

MODWRENCH WRENCH FOR TIGHTENING MODEL SCREWS 8,49 MPAP32G 22,42 22 22,42 22,42 22,42 22,42 22,42 MPFP34 22,42 MPFP36 MPFTC32 MPAPF36 MPAPF34 MPAP34G GINGIHUE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 4MM(H) PREFORMANCE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 4MM(H) PREFORMANCE 15 PRE-ANGLED POST 3.4MM(D) X 3.8MM(P) X 6MM(H) PREFORMANCE POST 3.4MM(D) X 3.8MM(P) X 4MM(H) PREFORMANCE POST 3.4MM(D) X 3.8MM(P) X 6MM(H) PREFORMANCE TEMPORARY CYLINDER 3.4MM (NON-HEXED)

Index
Cat.#
MPFTC34 MSGIAM1 MSGIAM2 MSGIAM3 MSGIAM4 MUCC2C MUCG1C MUCG2C MUNITS MWS15 NCATD0 NCATD0C NPSDK0 NTMOD1 ORCG1 ORCY1 ORLAU OSO20 OSO40 OSO60 OSOBLK OSOCA OSODH OSORED OSSMOD1 PAA484 PAA485 PAA654 PAA655 PAAP48 PAAP65 PAD00 PAD01 PAD24 PAK4140 PAK4155 PAK4240 PAK4255 PAK4340 PAK4355 PAK4440 PAK4455 PAK5140 PAK5155 PAK5240

Description
PREFORMANCE TEMPORARY CYLINDER 3.4MM (HEXED) NAVIGATOR CERTAIN ANALOG MOUNT, 3.4MM(D) X 1(L) NAVIGATOR CERTAIN ANALOG MOUNT, 3.4MM(D) X 2(L) NAVIGATOR CERTAIN ANALOG MOUNT, 3.4MM(D) X 3(L) NAVIGATOR CERTAIN ANALOG MOUNT, 3.4MM(D) X 4(L) UCLA CASTABLE NON-HEXED ABUTMENT CYLINDER 3.4MM(D) UCLA GOLD HEXED ABUTMENT CYLINDER 3.4MM(D) UCLA GOLD NON-HEXED ABUTMENT CYLINDER 3.4MM(D) SQUARE TRY-IN SCREW, 3.4MM(D) (5PK) IMPLANT WAXING SCREW FOR 3.4MM(D) CONTRA ANGLE TORQUE DRIVER KIT CONTRA ANGLE TORQUE DRIVER KIT CERTAIN PROSTHETIC DRIVER KIT 3X MODEL OF OSSEOTITE TAPERED IMPLANT GOLD HADER CLIP PLASTIC HADER CLIP UNIVERSAL O-RING ABUTMENT LAB ANALOG O-RING ABUTMENT 4.1MM(D) X 2MM(H) O-RING ABUTMENT 4.1MM(D) X 4MM(H) O-RING ABUTMENT 4.1MM(D) X 6MM(H) O-RING REPLACEMENTS O-RING CASTABLE SYSTEM O-RING HOUSING RED PROCESSING O-RING 3X MODEL OF OSSEOTITE IMPLANT 4MM(D) X 13MM(L) PROVIDE ABUTMENT ANALOG 4.8MM(P) X 4MM(H) PROVIDE ABUTMENT ANALOG 4.8MM(P) X 5.5MM(H) PROVIDE ABUTMENT ANALOG 6.5MM(P) X 4MM(H) PROVIDE ABUTMENT ANALOG 6.5MM(P) X 5.5MM(H) PROVIDE ABUTMENT ANALOG WITH PIN 4.8MM(P) PROVIDE ABUTMENT ANALOG WITH PIN 6.5MM(P) POSTERIOR ABUTMENT DRIVER 17MM(L) O-RING/DAL-RO ABUTMENT DRIVER 24MM(L) STANDARD ABUTMENT DRIVER 24MM(L) PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 1MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 1MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 2MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 2MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 3MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 3MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 4MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 4.1MM(D) X 4.8MM(P) X 4MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 6.5MM(P) X 1MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 6.5MM(P) X 1MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 6.5MM(P) X 2MM(H) - 4MM POST

Page#
32 54 54 54

Cat.#
PAK5255 PAK5340 PAK5355

Description
PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 6.5MM(P) X 2MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 4.8MM(P) X 3MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 6.5MM(P) X 3MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 4.8MM(P) X 4MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 5MM(D) X 4.8MM(P) X 4MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 1MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 1MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 2MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 2MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 3MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 3MM(H) - 5.5MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 4MM(H) - 4MM POST PROVIDE ABUTMENT PLACEMENT KIT 6MM(D) X 6.5MM(P) X 4MM(H) - 5.5MM POST

Page#
3 3 3 3 3 3 3 3 3 3 3 3 3 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25

54 31 31 31 26,30,50 14,18,34,38,50 51 51 51 56 20,40 20,40 44 43 43 43 44 44 44 44 56 4 4 4 4 4 4 14,18,34,38,51,52 46,52 14,18,34,51,52 3 3 3 3 3 3 3 3 3 3 3 PAP452G PAP454G PAP462G PAP464G PAP472G PAP474G PAP552G PAP554G PAP562G PAP564G PAP572G PAP574G PAP662G PAP664G PAP672G PAP674G PAPF454 PAPF456 PAPF554 PAPF556 PAPF664 PAPF666 PAK6455 PAK6355 PAK6440 PAK6340 PAK6255 PAK6155 PAK6240 PAK6140 PAK5455 PAK5440

GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 6MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 6MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 7.5MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 4.1MM(D) X 7.5MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 6MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 6MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 7.5MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 5MM(D) X 7.5MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 4MM(H) GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 7.5MM(P) X 2MM(H) GINGIHUE 15 PRE-ANGLED POST 6MM(D) X 7.5MM(P) X 4MM(H)

PREFORMANCE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 4MM(H) 47 PREFORMANCE 15 PRE-ANGLED POST 4.1MM(D) X 5MM(P) X 6MM(H) 47 PREFORMANCE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 4MM(H) 47 PREFORMANCE 15 PRE-ANGLED POST 5MM(D) X 5MM(P) X 6MM(H) 47 PREFORMANCE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 4MM(H) 47 PREFORMANCE 15 PRE-ANGLED POST 6MM(D) X 6MM(P) X 6MM(H) 47 56 56 47 47 32,48 32,48 52 52

PEMODLOC PATIENT ED MODEL - LOCATOR PEMODSM PATIENT ED MODEL - SINGLE/MULTIPLE TEETH PFP454 PFP456 PFTC41 PFTC42 PHD00N PHD01N PREFORMANCE POST 4.1MM(D) X 5MM(P) X 4MM(H) PREFORMANCE POST 4.1MM(D) X 5MM(P) X 6MM(H) PREFORMANCE TEMPORARY CYLINDER 4.1MM (HEXED) PREFORMANCE TEMPORARY CYLINDER 4.1MM (NON-HEXED) NARROW POSTERIOR SMALL HEX DRIVER 17MM(L) NARROW STANDARD SMALL HEX DRIVER 24MM(L)

Index
Cat.#
PHD02N PHD03N PIC484 PIC484H PIC485 PIC485H PIC654 PIC654H PIC655 PIC655H PPC484 PPC485 PPC654 PPC655 PPCA3 PPIA3 PPMC1 PPMM1 PPSA3 PRK484 PRK485 PRK654 PRK655 PSD00 PSD01 PSDT1 PSQD0N PSQD1N PTC345 PTC347 PTC455 PTC457 PTC465 PTC467 PTC475 PTC477 PTC555 PTC557 PTC665 PTC667 PUA48M PUA48S PUA65M PUA65S PWS48M PWS48S PWS65M PWS65S QKBRG RAOR1 RASA3 RASD1

Description
NARROW POSTERIOR LARGE HEX DRIVER 17MM(L) NARROW STANDARD LARGE HEX DRIVER 24MM(L) PROVIDE IMPRESSION COPING 4.8MM(P) X 4MM(H)

Page#
49,50,51,52 49,50,51,52 4 4 4 4 4 4 4 4 4 4 4 4 16,36 55 16,36,55 55 20,40,55 3 3 3 3 51 51 51 50,51,52 50,51,52 5 5 5 5

Cat.#
RASD6 RASH2N RASH3N RASH4 RASH7N RASH8N RASH9 RASQ3N RASQ8N RH600 RH600R RTI2035 RTI2035K

Description
RIGHT ANGLE SLOTTED DRIVER TIP 30MM(L) NARROW RIGHT ANGLE SMALL HEX DRIVER TIP 24MM(L) NARROW RIGHT ANGLE LARGE HEX DRIVER TIP 24MM(L) RIGHT ANGLE DRIVER TIP 50 IN. HEX 24MM(L) NARROW RIGHT ANGLE SMALL HEX DRIVER TIP 30MM(L) NARROW RIGHT ANGLE LARGE HEX DRIVER TIP 30MM(L) RIGHT ANGLE DRIVER TIP 50 IN. HEX 30MM(L) NARROW RIGHT ANGLE SQUARE DRIVER TIP 24MM(L) NARROW RIGHT ANGLE SQUARE DRIVER TIP 30MM(L) REAMER/HANDLE FOR SGC34, UNAB1/2 RH600 REAMER RESTORATIVE TORQUE INDICATOR RESTORATIVE TORQUE INDICATOR KIT

Page#
51 52 49,50,51,52 22,42,52 52 49,50,51,52 22,42,52 50,51,52 50,51,52 55 55 51 51 51 35 35 35 35 35 20,40 20,40 54 54 54 54 54 54 54 54 54 54

PROVIDE IMPRESSION COPING WITH HOLES 4.8MM(P) X 4MM(H) PROVIDE IMPRESSION COPING 4.8MM(P) X 5.5MM(H) PROVIDE IMPRESSION COPING WITH HOLES 4.8MM(P) X 5.5MM(H) PROVIDE IMPRESSION COPING 6.5MM(P) X 4MM(H) PROVIDE IMPRESSION COPING WITH HOLES 6.5MM(P) X 4MM(H) PROVIDE IMPRESSION COPING 6.5MM(P) X 5.5MM(H) PROVIDE IMPRESSION COPING WITH HOLES 6.5MM(P) X 5.5MM(H) PROVIDE PROTECTION CAP 4.8MM(P) X 4MM(H) PROVIDE PROTECTION CAP 4.8MM(P) X 5.5MM(H) PROVIDE PROTECTION CAP 6.5MM(P) X 4MM(H) PROVIDE PROTECTION CAP 6.5MM(P) X 5.5MM(H) POLISHING PROTECTOR CONICAL ABUTMENT 4.1 & 5MM(D) POLISHING PROTECTOR UCLA ABUTMENT 4.1MM(D) POLISHING PROTECTOR - CONICAL ABUTMENT 3.4MM(D) POLISHING PROTECTOR UCLA 3.4MM(D) POLISHING PROTECTOR STANDARD ABUTMENT PROVIDE ABUTMENT RESTORATIVE KIT 4.8MM(P) - 4MM POST PROVIDE ABUTMENT RESTORATIVE KIT 4.8MM(P) - 5.5MM POST PROVIDE ABUTMENT RESTORATIVE KIT 6.5MM(P) - 4MM POST PROVIDE ABUTMENT RESTORATIVE KIT 6.5MM(P) - 5.5MM POST POSTERIOR SLOTTED SCREW DRIVER - SLOTTED 17MM(L) STANDARD SLOTTED SCREW DRIVER - SLOTTED 24MM(L) PROSTHETIC SYSTEM DRIVER TRAY NARROW POSTERIOR SQUARE DRIVER 17MM(L) NARROW STANDARD SLOTTED SQUARE DRIVER 24MM(L) PREP-TITE CAP 5MM: USE WITH MAP32G, MAP34G PREP-TITE CAP 7MM: USE WITH MAP32G, MAP34G PREP-TITE CAP 5MM: USE WITH APP452G, APP454G PREP-TITE CAP 7MM: USE WITH APP452G, APP454G

RTI2035TR RESTORATIVE TORQUE INDICATOR TRAY SCA001 SCA002 SCA003 SCA004 SCA055 SGC30 SGC34 SGIAM41 SGIAM42 SGIAM43 SGIAM44 SGIAM51 SGIAM52 SGIAM53 SGIAM54 SGLKIT SGLTRAY SGUCA1C SIC70 SLA20 SQIC7 SRT01 CONICAL ABUTMENT GOLD STANDARD ZR 4.1MM(D) X 1MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 4.1MM(D) X 2MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 4.1MM(D) X 3MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 4.1MM(D) X 4MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 4.1MM(D) X 5.5MM(H) CHAMFERED GOLD CYLINDER FOR STANDARD ABUTMENT STANDARD ABUTMENT CASTABLE PLASTIC CYLINDER NAVIGATOR CERTAIN ANALOG MOUNT, 4.1MM(D) X 1(L) NAVIGATOR CERTAIN ANALOG MOUNT, 4.1MM(D) X 2(L) NAVIGATOR CERTAIN ANALOG MOUNT, 4.1MM(D) X 3(L) NAVIGATOR CERTAIN ANALOG MOUNT, 4.1MM(D) X 4(L) NAVIGATOR CERTAIN ANALOG MOUNT, 5MM(D) X 1(L) NAVIGATOR CERTAIN ANALOG MOUNT, 5MM(D) X 2(L) NAVIGATOR CERTAIN ANALOG MOUNT, 5MM(D) X 3(L) NAVIGATOR CERTAIN ANALOG MOUNT, 5MM(D) X 4(L) NAVIGATOR LABORATORY KIT NAVIGATOR LABORATORY TRAY

UCLA GOLD STANDARD ZR (HEXED) ABUTMENT CYLINDER 4.1MM(D) 29,31 TWIST LOCK IMPRESSION COPING STANDARD ABUTMENT LAB ANALOG (STAINLESS) PICK-UP IMPRESSION COPING HAND TAP FOR SRT10 HAND DRILL 14MM(D) BRONZE DRILL FOR SRT10 HAND DRILL 1.18MM(D) SILVER DRILL FOR SRT10 EXTRACTING DRILL - ISO LATCH FOR SRT10 GUIDE HANDLE FOR SRT10 SCREW REMOVING KIT CONICAL ABUTMENT GOLD STANDARD ZR 5MM(D) X 1MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 5MM(D) X 2MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 5MM(D) X 3MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 5MM(D) X 4MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 5MM(D) X 5.5MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 6MM(D) X 1MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 6MM(D) X 2MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 6MM(D) X 3MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 6MM(D) X 4MM(H) CONICAL ABUTMENT GOLD STANDARD ZR 6MM(D) X 5.5MM(H) 20,40 20,40 20,40 55 55 55 55 55 55 35 35 35 35 35 35 35 35 35 35

PREP-TITE CAP 5MM: USE WITH APP462G, APP464G, WPP562G, WPP564G 5 PREP-TITE CAP 7MM: USE WITH APP462G, APP464G, WPP562G, WPP564G 5 PREP-TITE CAP 5MM: USE WITH APP472G, APP474G, WPP572G, WPP574G, WPP672G, WPP674G PREP-TITE CAP 7MM: USE WITH APP472G, APP474G, WPP572G, WPP574G, WPP672G, WPP674G PREP-TITE CAP 5MM: USE WITH WPP552G, WPP554G PREP-TITE CAP 7MM: USE WITH WPP552G, WPP554G PREP-TITE CAP 5MM: USE WITH WPP662G, WPP664G PREP-TITE CAP 7MM: USE WITH WPP662G, WPP664G PROVIDE TEMPORARY CYLINDER MULTI-UNIT - 4.8MM PROFILE PROVIDE TEMPORARY CYLINDER SINGLE-UNIT - 4.8MM PROFILE PROVIDE TEMPORARY CYLINDER MULTI-UNIT - 6.5MM PROFILE PROVIDE TEMPORARY CYLINDER SINGLE-UNIT - 6.5MM PROFILE PROVIDE WAXING SLEEVE 4.8MM(P) MULTI-UNIT PROVIDE WAXING SLEEVE 4.8MM(P) SINGLE-UNIT PROVIDE WAXING SLEEVE 6.5MM(P) MULTI-UNIT PROVIDE WAXING SLEEVE 6.5MM(P) SINGLE-UNIT QUICKBRIDGE RIGHT ANGLE O-RING/DAL-RO ABUTMENT DRIVER TIP RIGHT ANGLE ABUTMENT DRIVER TIP - STEEL RIGHT ANGLE SLOTTED DRIVER TIP 24MM(L) 5 5 5

SRT02 SRT03 SRT04

5 SRT05 5 SRT10 5 SWCA51 4 SWCA52 4 SWCA53 4 SWCA54 4 SWCA55 4 SWCA61 4 SWCA62 4 SWCA63 4 SWCA64 16,36 SWCA65 44,46,52 SWGA51C 14,18,34,38,51,52 SWGA61C 51 UCLA GOLD STANDARD ZR (HEXED) ABUTMENT CYLINDER 6MM(D) 29,31 UCLA GOLD STANDARD ZR (HEXED) ABUTMENT CYLINDER 5MM(D) 29,31

Index
Cat.#
TC300 TD-10 TD-20 TD-35 THRC4 THRC6 UNA125 UNA225 UNAB1C UNAB2C UNIHG UNIHT UNISG UNITS WAB200 WAB300 WAB400 WAB550 WCAP564 WCAP574 WCLA6 WCP661 WCP662 WCP671 WCPP6 WCS66 WCS67 WCT661 WCT662 WCT671 WCT672 WCTC60 WCTC61 WCTC671 WGA51C WGA52C WGA61C WGA62C WIP55 WIP56 WIP57 WIP66 WIP67 WIT55 WIT56 WIT57 WIT66 WIT67 WLT10 WOSO20 WOSO40

Description
STANDARD ABUTMENT TEMPORARY CYLINDER CONTRA ANGLE TORQUE CONTROLLER 10NCM CONTRA ANGLE TORQUE CONTROLLER 20NCM CONTRA ANGLE TORQUE CONTROLLER 32NCM TEMPORARY HEALING RETENTION CYLINDER 4.1MM(D) X 4MM(H) TEMPORARY HEALING RETENTION CYLINDER 4.1MM(D) X 6MM(H) UCLA CASTABLE (HEXED) ABUTMENT CYLINDER (25PK) UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER (25PK) UCLA CASTABLE (HEXED) ABUTMENT CYLINDER UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER GOLD-TITE (HEXED) SCREW TITANIUM (HEXED) SCREW GOLD-TITE SQUARE SCREW SQUARE TRY-IN SCREW (5PK) 4.1, 5, 6MM(D) STANDARD ABUTMENT 5MM(D) X 2MM(H) STANDARD ABUTMENT 5MM(D) X 3MM(H) STANDARD ABUTMENT 5MM(D) X 4MM(H) STANDARD ABUTMENT 5MM(D) X 5.5MM(H) ZIREAL POST 5MM(D) X 6MM(P) X 4MM(H) ZIREAL POST 5MM(D) X 7.5MM(P) X 4MM(H) CONICAL ABUTMENT LAB ANALOG 6MM(D) CONICAL EP PICK-UP COPING (HEXED) 6MM(D) X 6MM(P) CONICAL EP PICK-UP COPING (NON-HEXED) 6MM(D) X 6MM(P) CONICAL EP PICK-UP COPING (HEXED) 6MM(D) X 7.5MM(P) POLISHING PROTECTOR CONICAL ABUTMENT 6MM CONICAL EP HEALING CAP 6MM(D) X 6MM(P) CONICAL EP HEALING CAP 6MM(D) X 7.5MM(P) CONICAL EP TWIST LOCK COPING (HEXED) 6MM(D) X 6MM(P)

Page#
20,40 51 51 51 39,41,43,45 39,41,43,45 29,31

Cat.#
WOSO60 WPC51C WPC52C WPC61C WPC62C WPFP554 WPFP556 WPFP664 WPFP666

Description
O-RING ABUTMENT 5MM(D) X 6MM(H) UCLA CASTABLE (HEXED) ABUTMENT CYLINDER 5MM(D) UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER 5MM(D) UCLA CASTABLE (HEXED) ABUTMENT CYLINDER 6MM(D) UCLA CASTABLE (NON-HEXED) ABUTMENT CYLINDER 6MM(D) PREFORMANCE POST 5MM(D) X 5MM(P) X 4MM(H) PREFORMANCE POST 5MM(D) X 5MM(P) X 6MM(H) PREFORMANCE POST 6MM(D) X 6MM(P) X 4MM(H) PREFORMANCE POST 6MM(D) X 6MM(P) X 6MM(H) PREFORMANCE TEMPORARY CYLINDER 5MM (HEXED) PREFORMANCE TEMPORARY CYLINDER 5MM (NON-HEXED) PREFORMANCE TEMPORARY CYLINDER 6MM (HEXED) PREFORMANCE TEMPORARY CYLINDER 6MM (NON-HEXED) POLISHING PROTECTOR 5MM(D) GINGIHUE POST 5MM(D) X 5MM(P) X 2MM(H) GINGIHUE POST 5MM(D) X 5MM(P) X 4MM(H) GINGIHUE POST 5MM(D) X 6MM(P) X 2MM(H) GINGIHUE POST 5MM(D) X 6MM(P) X 4MM(H) GINGIHUE POST 5MM(D) X 7.5MM(P) X 2MM(H) GINGIHUE POST 5MM(D) X 7.5MM(P) X 4MM(H) POLISHING PROTECTOR 6MM(D) GINGIHUE POST 6MM(D) X 6MM(P) X 2MM(H) GINGIHUE POST 6MM(D) X 6MM(P) X 4MM(H) GINGIHUE POST 6MM(D) X 7.5MM(P) X 2MM(H) GINGIHUE POST 6MM(D) X 7.5MM(P) X 4MM(H) WAXING SCREW/GUIDE PIN-KNURLED 10MM(L) WAXING SCREW/GUIDE PIN-KNURLED 15MM(L) WAXING SCREW/GUIDE PIN-KNURLED 20MM(L) KNURLED IMPLANT WAXING SCREW/GUIDE PIN TEMPORARY (HEXED) IMPLANT CYLINDER 5MM(D) TEMPORARY (NON-HEXED) IMPLANT CYLINDER 5MM(D) TEMPORARY (HEXED) IMPLANT CYLINDER 6MM(D) TEMPORARY (NON-HEXED) IMPLANT CYLINDER 6MM(D)

Page#
43 29,31 31 29,31 31 47 47 47 47 32,48 32,48 32,48 32,48 55 25 25 25 25 25 25 55 25 25 25 25 14,18,34,38,50 50 50 50 32 32 32 32

31 WPFTC51 29,31 WPFTC52 31 WPFTC61

26,28,30,32,50 WPFTC62 26,28,30,32,50 WPP50 26,28,30,32,50 WPP552G 26,28,30,32,50 WPP554G 39 WPP562G 39 WPP564G 39 WPP572G 39 WPP574G 27 WPP60 27 WPP662G 16,36 WPP664G 16,36 WPP672G 16,36 WPP674G 16,36 WSK10 16,36,55 WSK15 16,36 WSK30 16,36 WSU30 16,36 WTCS51 WTCS52

CONICAL EP TWIST LOCK COPING (NON-HEXED) 6MM(D) X 6MM(P) 16,36 CONICAL EP TWIST LOCK COPING (HEXED) 6MM(D) X 7.5MM(P) 16,36 WTCS61 CONICAL EP TWIST LOCK COPING (NON-HEXED) 6MM(D) X 7.5MM(P) 16,36 WTCS62 CONICAL TEMPORARY CYLINDER (HEXED) 6MM(D) X 6MM(P) 16,36 CONICAL TEMPORARY CYLINDER (NON-HEXED) 6MM(D) X 6MM(P) 16,36 CONICAL TEMPORARY CYLINDER (NON-HEXED) 6MM(D) X 7.5MM(P) 16,36 UCLA GOLD (HEXED) ABUTMENT CYLINDER 5MM(D) UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 5MM(D) UCLA GOLD (HEXED) ABUTMENT CYLINDER 6MM(D) UCLA GOLD (NON-HEXED) ABUTMENT CYLINDER 6MM(D) IMPLANT EP PICK-UP COPING 5MM(D) X 5MM(P) IMPLANT EP PICK-UP COPING 5MM(D) X 6MM(P) IMPLANT EP PICK-UP COPING 5MM(D) X 7.5MM(P) IMPLANT EP PICK-UP COPING 6MM(D) X 6MM(P) IMPLANT EP PICK-UP COPING 6MM(D) X 7.5MM(P) IMPLANT EP TWIST LOCK COPING 5MM(D) X 5MM(P) IMPLANT EP TWIST LOCK COPING 5MM(D) X 6MM(P) IMPLANT EP TWIST LOCK COPING 5MM(D) X 7.5MM(P) IMPLANT EP TWIST LOCK COPING 6MM(D) X 6MM(P) IMPLANT EP TWIST LOCK COPING 6MM(D) X 7.5MM(P) UCLA WIDE DIAMETER O-RING ABUTMENT 5MM(D) X 2MM(H) O-RING ABUTMENT 5MM(D) X 4MM(H) 29,31 31 29,31 31 26,28,30,32 26,28,30,32 26,28,30,32 26,30,32 26,30,32 26,28,30,32 26,28,30,32 26,28,30,32 26,30,32 26,30,32 55 43 43

Ordering Form
Copy and fax completed form to BIOMET 3i Customer Service at 561-776-1272. Existing Customer: I Yes
Patient Name: Billing Information I No

Name

Account Number

Date Order Placed

Street Address/Suite #

Order Placed By

P.O. Number

City Shipping Information

State

Zip Code

Phone (Include Area Code) Payment Method I

Fax (Include Area Code)

Credit Card (please circle card) Visa MasterCard American Express

Name

Card No. ___________________________ Exp. Date ___________________________

Street Address/Suite #

I I

COD Bill Net 30

City

State

Zip Code

Shipping Method (check one) I Economy I Standard Overnight Item Numbers I Priority Overnight I Saturday Delivery Quantity Description

I UPS

Thank you for your patronage! For further assistance, call BIOMET 3i Customer Service at 800-342-5454.

Ordering Information
Some products may not be available outside the U.S.A. Algunos productos no se comercializan fuera de EE.UU. Certains produits ne sont pas disponibles en dehors des tats-Unis. Einige Produkte sind auerhalb der USA nicht erhltlich.
BIOMET 3i, Inc. and Purchaser, products sold hereunder are only for use in the United States. Purchaser agrees that the Purchaser will comply fully with all applicable state and federal laws and regulations and Purchaser shall indemnify BIOMET 3i, Inc. for all losses, damages and penalties incurred as a result of any violation of applicable state or federal law or regulations. The advertised devices may not have been licensed in accordance with Canadian Law.

To Place an Order:
Contact your local BIOMET 3i, Inc. Representative or call: BIOMET 3i, Inc. Customer Service MondayThursday 8am8pm (EST) Friday 8am6:30pm (EST) 800-342-5454 Fax 561-776-1272 In Canada: 800-363-1980 Outside US: 561-776-6700

FORCE MAJEURE. BIOMET 3i, Inc. shall not be liable for any loss or damage due to failure or delay arising out of any cause beyond the reasonable control of BIOMET 3i, Inc. In the event of any failure or delay resulting from such causes, an equitable adjustment of delivery and any other appropriate terms and conditions shall be made. No such failure or delay shall be the basis for an increase in BIOMET 3i, Inc.s obligations nor any termination by Purchaser. LIMITATION OF LIABILITY. UNDER NO CIRCUMSTANCES SHALL BIOMET 3i, INC. OR ANY OF ITS AFFILIATES BE LIABLE FOR BUSINESS INTERRUPTION, LOSS OF PROFITS, SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE AND FROM ANY CAUSE WHETHER BASED IN CONTRACT, WARRANTY OR TORT (INCLUDING NEGLIGENCE) OR OTHER LEGAL THEORY, EVEN IF BIOMET 3i, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. VALIDITY. If any provision of these Terms and Conditions is found to be illegal or unenforceable in any respect, such illegality or unenforceability shall not affect any other provision of these Terms and Conditions, all of which shall remain enforceable in accordance with their terms. GENERAL PROVISIONS. The purchase of the products and these Terms and Conditions are governed by the laws of Florida, without regard to conflicts of law principles. This document incorporates all oral and written representations between the parties and constitutes the entire agreement and understanding of the parties with respect to the subject matter hereof and supercedes any and all other agreements either oral or written between the parties with respect to such subject matter. No amendment or modification may be made to this document unless in writing and duly executed by an authorized representative of BIOMET 3i, Inc. CAUTION. Federal (U.S.) Law restricts these devices to sale by or on the order of a
licensed healthcare practitioner. Devices labeled STERILE are certified to be sterile unless sterile package is opened or damaged.

TERMS AND CONDITIONS OF SALE. The following are the terms and conditions
by which BIOMET 3i, Inc. sells its products.

GOVERNING TERMS. Any shipment of products shall be deemed to be on the terms and conditions stated herein. Any and all terms and conditions submitted by Purchaser are hereby rejected. TAXES. The prices set forth herein do not include any sales, use, excise, ad valorem, property or other taxes applicable to the sale, use or delivery of the products, all of which shall be paid by Purchaser separately or added to the contract price and paid by Purchaser to BIOMET 3i, Inc. PRICES. The prices set forth for the products are in United States Dollars. DELIVERY. Products sold hereunder shall be delivered F.O.B. manufacturers plant or distributors plant, as applicable. Purchaser shall assume responsibility for all subsequent delivery or shipping charges. PAYMENT. Payment terms shall be as set forth under the Terms section on front of
invoice.

WARRANTY. EXCEPT AS EXPRESSLY SET FORTH IN THE BIOMET 3i, INC. FIVE
YEAR WARRANTY PROGRAM, NEITHER BIOMET 3i, INC. NOR ANY OF ITS AFFILIATES MAKE ANY WARRANTY, EXPRESS OR IMPLIED, EXCEPT THAT ITS PRODUCTS SHALL BE FREE FROM DEFECTS IN MATERIAL AND/OR WORKMANSHIP. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL PURCHASER. IN THE EVENT OF A PRODUCT DEFECT, IMMEDIATELY NOTIFY BIOMET 3i, INC. OF THE DEFECT PRIOR TO RETURNING THE PRODUCT. DEVICES SHALL BE STERILIZED PRIOR TO RETURN. AS ITS SOLE OBLIGATION AND AS PURCHASERS SOLE REMEDY UNDER THIS WARRANTY, BIOMET 3i, INC. WILL, AT ITS OPTION, EITHER REPAIR, REPLACE OR ISSUE CREDIT FOR SUCH PRODUCTS. PURCHASER ASSUMES ALL RISKS AND LIABILITY RESULTING FROM THE USE OF THESE PRODUCTS, WHETHER USED SEPARATELY OR IN COMBINATION WITH OTHER PRODUCTS. EXCEPT FOR THE WARRANTY EXPRESSLY DESCRIBED IN WARRANTY PARAGRAPH ABOVE, NEITHER BIOMET 3i, INC. NOR ANY OF ITS AFFILIATES MAKES ANY OTHER WARRANTY WITH RESPECT TO THE BIOMET 3i, INC. PRODUCTS, EXPRESSED OR IMPLIED, WRITTEN OR ORAL, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

EXPORT ORDERS. Require advance payment or letter of credit. Shipments are made either freight collect or paid by BIOMET 3i, Inc. and added to invoice. Unless special instructions are received with the order, the shipping method will be determined by BIOMET 3i, Inc., F.O.B. Palm Beach Gardens, FL. TRADEMARKS. BIOMET 3i LLC. Registered Trademarks: BIOMET 3i and design, BIOMET 3i IDS Learning Library, BIOMET 3i Innovative Dental Seminars, BIOMET 3i Synergy Training Program, ACT, Advanced Cutting Technology, ARCHITECH PSR, Better For Your Patients. Better For Your Practice, Biogran, Bone Bonding, CAM StructSURE, Certain, Click, Quick and Easy, DIEM, Encode, EP, GingiHue, Gold-Tite, Implant Innovations, IOL, Miniplant, Navigator, OSSEOCISION, OsseoGuard, OSSEOTITE, OSSEOTITE NT, OSSEOTITE XP, Patient Specific Restorations, PreFormance, Prep-Tite, PREVAIL, Provide, QuickBridge, QuickSeat, RegenerOss, STA, STP, TG OSSEOTITE and ZiReal are registered trademarks of BIOMET 3i LLC.
BIOMET 3i LLC. Trademarks: BIOMET 3i, BIOMET 3i IDS, DCD, Gold Post, Gold Standard ZR, ICE, Lok-Ball, Lok-Cap, NanoTite, SIMPLE LOGIC, Simply Impressive, Snap-Cap, Spiral Ice, Steady State Stability, Twist Lock and Wave Form Thread are trademarks of BIOMET 3i LLC. BIOMET is a registered trademark of BIOMET, Inc. Calcigen is a trademark of BIOMET, Inc. Dolder is a registered trademark of Prof. Eugen Dolder, formerly the director of the School of Dentistry at the University of Zurich. Endobon is a registered trademark of BIOMET Deutschland GmbH. LOCATOR is a registered trademark of Zest Anchors, Inc. OSSIX is a trademark of ColBar Life Science Ltd. Safescraper is a registered trademark of CGM S.p.A Divisione Medicale META. PATENT NOTICE: Angled Abutments Products are licensed under one or more U.S. Patent Nos. 5,000,685; 5,069,622; and 5,087,200. CAM StructURE is licensed under U.S. Patent No. 6,382,975. Asyst System is covered by U.S. Patent Nos. 5,322,443; 5,437,550; 5,462,436; and 5,692,904. Biogran Products are covered by U.S. Patent No. 5,204,106. Bone Profiler Products are covered by U.S. Patent No. RE 38,630. Certain Implants are licensed under U.S. Patent No. 4,960,381 and covered by U.S. Patent No. 7.338.286. Conical Abutment products are covered by U.S. Patent No. 4,850,870. Drill Stop Products are covered by U.S. Patent No. 6,514,258. Encode and ARCHITECH are covered by U.S. Patent No. 6,558,162 and 6,790,040. EP System is covered by U.S. Patent Nos. 5,674,071; 6,129,548; 6,565,357; RE. 36,126; and RE. 36,389. Gold Post Products are covered by U.S. Patent No. 5,829,977. Gold Standard Products are covered by U.S. Patent Nos. 5,725,375; and 5,984,680. GoldTite Products are covered by U.S. Patent Nos. 5,879,161; and 6,287,116. OSSEOTITE Implants are covered by U.S. Patent Nos. 5,071,351; 5,603,338; 5,876,453; 5,863,201; 6,491,723; and 6,652,765. ICE Implants are covered by U.S. Patent No. 5,727,943. Lok-Ball, Lok-Cap, TG Post and TG Preparation Coping are covered by U.S. Patent No. 6,758,672. No Touch System is covered by U.S Patent No. 5,582,299. NanoTite Implants are covered by U.S. Patent No. 7.169.317. Precision Abutment Base is covered by U.S. Patent No. 4,988,298. Spiral ICE is licensed under U.S. Patent No. 5,897,319. Stabilized Casting Core Products are covered by U.S. Patent No. 5,702,252. STA System is covered by U.S. Patent No. 6,227,856. Tapered Driver Products are covered by U.S. Patent No. 5,105,690. Temporary Dental Coping Products are covered by U.S. Patent Nos. 5,006,069; and 5,040,983. Torque Indicator is covered by U.S. Patent Nos. 6,186,785; and 6,398,552. TG OSSEOTITE Products are covered by U.S. Patent No. 6,217,331; and 6,159,010. Twist Lock Products are covered by U.S. Patent Nos. 4,955,811; 5,685,715; 5,938,443; and 6,290,499. ZiReal Products are covered by U.S. Patent Nos. RE 37,227; 6,168,435; 5,685,714; 5,947,732; 5,989,026; 6,152,737; and 6,343,930. Wave Form Thread Product is covered by U.S. Patent Nos. 5,902,109; and 6,431,869. Other patents pending.

EDUCATION; MODIFICATION OF PRODUCTS. BIOMET 3i, Inc. strongly


recommends completion of formal post graduate implant education and strict adherence to the procedures described in BIOMET 3i, Inc.s Implant Instruction Manuals. BIOMET 3i, Inc. continually strives to improve its products and therefore reserves the right to improve, modify or discontinue products at any time, or to change specifications of the products without notice and without incurring any obligation.

RETURN POLICY. A Purchaser may return any BIOMET 3i, Inc. Product within 90
days of the invoice date. BIOMET 3i, Inc. Products returned within 60 days of the invoice date will be accepted without any re-stocking fee to the Purchaser. BIOMET 3i, Inc. Products returned between 61 and 90 days of the invoice date will be subject to a 15% restocking fee. A BIOMET 3i, Inc. Product will be accepted for return only if the BIOMET 3i, Inc. Product is (1) returned in its original, unopened package (including autoclavable products); (2) received by BIOMET 3i, Inc. within 90 days after the invoice date for that product; and (3) returned freight prepaid to 4555 Riverside Drive, Palm Beach Gardens, Florida 33410, (Attention: Returns Department) accompanied by the BIOMET 3i, Inc. Return authorization number provided by BIOMET 3i, Inc.s Customer Service Department. Purchaser should be advised that BIOMET 3i, Inc. Products not meeting the above criteria will not be accepted for return.

EXCHANGE POLICY. BIOMET 3i, Inc. Products may be exchanged within 180 days of the invoice date, without a re-stocking fee, for other BIOMET 3i, Inc. Products of equal or lesser value within the same product family as determined by BIOMET 3i, Inc. (ex. implant for implant, abutment for abutment, membrane for membrane). BIOMET 3i, Inc. Products may be exchanged within 180 days of the invoice date for other BIOMET 3i, Inc. Products of greater value within the same product family as determined by BIOMET 3i, Inc. (ex. implant for implant, abutment for abutment, membrane for membrane), with the price differential paid by the Purchaser. In both cases, the exchanged BIOMET 3i, Inc. Product must be (1) returned in its original, unopened package (including autoclavable products); (2) a currently offered BIOMET 3i, Inc. Product (discontinued product not included); and (3) returned freight prepaid to 4555 Riverside Drive, Palm Beach Gardens, Florida 33410, (Attention: Returns Department) and accompanied by the BIOMET 3i, Inc. Return Authorization Number provided by BIOMET 3i, Inc.s Customer Service Department. LICENSES, PERMITS AND EXPORT CONTROL. The timely securing of permits,
licenses or other local, state or federal governmental approvals required in connection with Purchasers use of any products hereunder shall be the sole responsibility of Purchaser and Purchaser shall bear the cost thereof. Unless otherwise agreed between

Global Headquarters 4555 Riverside Drive Palm Beach Gardens, FL 33410 1-800-342-5454 Outside The U.S.: +1-561-776-6700 Fax: +1-561-776-1272 www.biomet3i.com

To Receive Information About BIOMET 3is Products, Services And Events By Email, Visit Our Website At www.biomet3i.com

REV A 01/10