Академический Документы
Профессиональный Документы
Культура Документы
Page 1 of 1
Issued :
13.05.2011
Bulletin No : SUBJECT :
DFS-06/2011
Introduction new range of 18K & 24K Estrella (R410A) Model in Hiwall Category
Purpose: - This bulletin is introducing new range of 18K & 24K Estrella R410A
Model. Currently we are full system import of 18K Estrella Hi wall with 5 Star rating & 22k Estrella Hiwall with 4 star rating are having R22 as refrigerant. Now Hiwall developed with R410a refrigerant having 18k & 22k in 5Star range.Estrella R410a model delivers high energy efficiency to m eet the BEE regulation requirem ent.
Technical Specifications: OUTDOOR & INDOOR UNIT SPECIFICATIONS IDU : 42KGV-018A ODU : 51MSV-18RA
MODEL
Function Power Supply
Cooling 230-1ph-50 Hz W 5525 Btu/h Capacity 18850 Running Current A 7.4 Electrical Data Power Input W 1625 Type Rotary Model PA200M2CS-4KU2 Capacitor 45 MFD Compressor Lock Rotor Amps 37 Indoor Unit Outdoor unit Type Cross flow Propeller RPM(Hi//Med/Lo) 1260/1210/1120 780 Capacitor 3 MFD 5 MFD Fan Motor model number YDK36-4C(A) E - 1152 / 29HGE710T Control Capillary Refrigerant (R410a) Charge (g) 1600 Type Flare Connection OD(Liquid/suction) 1/4,1/2 Conductor 0.5 construction(pcs/mm) Interconnecting W ire Length(mts) 4.5 Dimension(WxHxD) mm 1084*320*221 907*690*354 Net. Weight kg 14 49
Cooling 230-1ph-50 Hz 6400 21837 9.0 2000 Rotary PA240M2CS-4KU1 50 MFD 37 Indoor Unit Outdoor unit Cross flow Propeller 1260/1210/1120 780 3 MFD 5 MFD YDK36-4C(A) E - 1152 / 29HGE710T Capillary 1600 Flare 1/4,5/8 0.5 4.5 1084*320*221 14 907*797*354 60
MODEL
MODEL DESCRIPTION
STAR RATING
Outdoor Estrella R410a -18K Indoor Split Outdoor Estrella R410a -24K Indoor Split
5002165 1.5 TR ESTRELLA OUTDOOR (51MSV-018-RA) 5002166 1.5 TR ESTRELLA IDU (42KGV-018A) 5002167 18K Estrella Split AC 5002169 2.0 TR ESTRELLA OUTDOOR (51MSV-024-RA) 5002170 2.0 TR ESTRELLA IDU (42KGV-024A) 5002172 24K Estrella Split AC 5 STAR 5 STAR
A 667 797
B 327 392
Notes: Always change filter drier whenever compressor is replaced. Always refer installation manual before installation of R410a Estrella Model. For additional length of interconnecting tube thickness & gas qty please refer above mentioned table. Due to R410a refrigerant system pressure will be high, it is recommended to use factory authorized parts only.
Troubleshooting Tips for Error codes (Indoor Unit) :Codes E1 Problem EEROM error Solution 1. Shut off the power supply and turn on it 5s later. 2. If the problem comes out again then replace the main PCB of indoor unit. 1. Unplug the power cord and plug it after 2 seconds. 2. If the problem remains then replace the main PCB of indoor unit. 1. Shut off the power supply and turn on it 5s later. 2. Turn off the unit, rotate the blower & check whether it rotates freely? 3. Check whether indoor fan motor connections are good? 4. If the problem comes out again then replace the indoor PCB 1. Check if the operation condition is normal especially the outdoor unit? 2. Check whether wiring is as per the outdoor powering wiring diagram. 1. Check the connections between the sensors and the PCB. 2. Are these connections good? 3. Replace the corresponding sensor and check if the errors happen again? 4 If the problem comes out again then replace the indoor PCB
E2
No crossing-zero signal
E3
E4
Over current protection of the compressor occurs 4 times Indoor room temp. sensor is open circuit or short circuit Temp. sensor on indoor evaporator is open circuit or short circuit
E5 E6