CONCRETING WORK SOR 1 SCHEDULE OF RATES CONCRETING WORK S/N 1 DESCRIPTION Lean Concrete (1:3:6) to underside of foundations, ground

beams etc mechanically mixed irrespective of thickness. Lean Concrete (1:2:4) to underside of foundations, beams, slabs etc mechanically mixed irrespective of thickness. Reinforced Concrete in foundations, ground beams, column stumps etc mechanically mixed, working around rod or fabric reinforcement below ground floor level (reinforcement measured separately). 3 4 5 6 7 8 9 10 Grade 20 Grade 25 Grade 30 Grade 35 Grade 40 Grade 45 Grade 50 Reinforced Concrete (Grade 40) in pile caps including excavation to the required depths, and necessary back filling, lean concrete to underside of pile cap base, all necessary steel reinforcement and formwork to sides of pile cap (rate only applicable for amendments in pilecap or amendments due to pile eccentricity). Reinforced Concrete to suspended slabs, beams, columns, staircases, walls etc mechanically mixed, working around rod or fabric reinforcement above ground floor level (reinforcement measured separately). 11 12 13 14 Grade 20 Grade 25 Grade 30 Grade 35 m3 m3 m3 m3 142.50 145.30 148.10 151.30 m3 m3 m3 m3 m3 m3 m3 m3 148.20 151.30 154.10 157.40 161.45 164.40 155.50 216.20 UNIT m3 m3 RATE ($) 131.80

134.50

CONCRETING WORK SOR 2 SCHEDULE OF RATES CONCRETING WORK S/N DESCRIPTION Reinforced Concrete to suspended slabs, beams, columns, staircases, walls etc mechanically mixed, working around rod or fabric reinforcement above ground floor level (reinforcement measured separately):- Contd) 15 16 Grade 40 Reinforced Concrete (Grade 40) to water tank mechanically mixed with approved type of Chloride-Free retarding superplasticiser, working around rod or fabric reinforcement (reinforcement measured separately). Grade 45 Grade 50 Supply and lay approved damp proof membrane complied with BS 6398 Type B (felt fibre base) to underside of reinforced concrete slab including provision for laps and preparation of surface. Mild Steel Rod Reinforcement, fabricated and laid in foundations, beds, suspended slab, walls, columns, beams, staircases etc, and including labour for forming stirrups, links :20 21 22 23 24 25 26 27 28 29 6mm diameter etc 8mm diameter 10mm diameter 13mm diameter 16mm diameter 20mm diameter 22mm diameter 25mm diameter 28mm diameter 32mm diameter kg kg kg kg kg kg kg kg kg kg 1.60 1.60 1.50 1.50 1.50 1.40 1.40 1.40 1.40 1.40 m3 m3 132.45 163.75 UNIT RATE ($)

17 18 19

m3 m3 m2

158.20 161.00 7.50

CONCRETING WORK SOR 3 SCHEDULE OF RATES CONCRETING WORK S/N DESCRIPTION Deformed High Tensile Steel Rod Reinforcement, fabricated and laid in foundations, beds, suspended slabs, walls, columns, beams, staircases etc, and including labour for forming stirrups, links etc :30 31 32 33 34 35 36 37 38 39 40 41 6mm diameter etc 7mm diameter 8mm diameter 10mm diameter 13mm diameter 16mm diameter 20mm diameter 22mm diameter 25mm diameter 28mm diameter 32mm diameter Extra over steel rod reinforcement for galvanising. Welded steel fabric reinforcement well lapped and tied at joints (measured nett):42 43 44 45 46 47 A5. A6. A7. A8. A10. A12. m2 m2 m2 m2 m2 m2 3.45 4.60 5.75 7.40 11.30 12.00 kg kg kg kg kg kg kg kg kg kg kg kg 1.50 1.50 1.50 1.50 1.50 1.50 1.40 1.40 1.40 1.40 1.40 1.10 UNIT RATE ($)

CONCRETING WORK SOR 4 SCHEDULE OF RATES CONCRETING WORK S/N DESCRIPTION Welded steel fabric reinforcement well lapped and tied at joints (measured nett) :- (Contd) 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 B5. B6. B7. B8. B8A. B9. B10. B12. B13. D4. D5. D6. D7. D8. D9. D10. D11. D12. D13. Dowel mesh (DM). m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 m2 4.90 5.65 6.40 8.30 4.90 9.80 11.10 13.30 18.50 12.80 5.20 6.65 8.45 10.85 13.70 16.90 20.30 24.150 28.40 5.60 UNIT RATE ($)

CONCRETING WORK SOR 5 SCHEDULE OF RATES CONCRETING WORK S/N DESCRIPTION Supply and fix prefabricated beam stirrup cage reinforcement:68 69 70 71 72 73 74 75 76 Reference no. S07. Reference no. S10. Reference no. S15. Reference no. S20. Reference no. S25. Reference no. S130. Reference no. S137. Reference no. 2S130 (twin). Supply and fix prefabricated beam capping cage reinforcement no. R10-300. Supply and fix prefabricated wall mesh reinforcement :77 78 Type H1320 0820. Type H1310 0820. Supply and fix prefabricated column link cage of R6 reinforcement (Reference no. L36, L36A, L36B, L46, L46A, L46B, L56, L56A, L56B) :79 80 81 82 At 100mm spacing. At 150mm spacing. At 175mm spacing. At 200mm spacing. m2 m2 m2 m2 5.30 4.40 4.10 3.90 m2 m2 9.40 15.40 m2 m2 m2 m2 m2 m2 m2 m2 m2 13.10 10.50 8.00 6.80 6.00 15.80 20.10 28.70 11.700 UNIT RATE ($)

CONCRETING WORK SOR 6 SCHEDULE OF RATES CONCRETING WORK S/N DESCRIPTION Supply and fix prefabricated column link cage of R8 reinforcement (Reference no. L38, L38A, L38B, L48, L48A, L48B, L58, L58A L58B) :83 84 85 86 87 At 100mm spacing. At 150mm spacing. At 200mm spacing. At 250mm spacing. Timber formwork to surfaces of concrete foundations, column stumps, ground beams, ground floor slabs, etc. Timber formwork to curved surfaces of concrete foundations, column stumps, ground beams, ground floor slabs, etc. Timber formwork to surfaces of concrete columns, walls, suspended slabs, stairs, canopies, beams, lintols etc. Timber formwork to produce a good off-form finish to surfaces of concrete columns, walls, suspended slabs, stairscases, canopies, beams, lintols, etc. Formwork of approved materials to produce a good off-form finish to curved surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols, etc. Oiled moisture resistant plywood formwork to surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols etc.. Oiled moisture resistant plywood formwork to curved surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols etc.. Single phenolytic coated shuttering board to surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols, etc. Single phenolytic coated shuttering board to curved surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols, etc. m2 m2 m2 m2 m2 m2 m2 m2 7.70 5.900 5.10 4.50 10.90 UNIT RATE ($)

88

22.50

89

17.40

90

26.95

91

m2

32.60

92

m2

24.10

93

m2

26.70

94

m2

26.80

95

m2

28.50

CONCRETING WORK SOR 7 SCHEDULE OF RATES CONCRETING WORK S/N 96 DESCRIPTION LABOUR ONLY for preparing, cleaning, assembling, erecting and dismantling of metal formwork of any types to surfaces of concrete columns, walls, suspended slabs, staircases, canopies, beams, etc. PRECAST CONCRETE with reinforcement in heel stones, sills, lintols, slabs, etc. including moulds, hoisting and fixing in position. 97 98 99 100 Grade 20 Grade 25 Grade 30 Grade 40 PRECAST CONCRETE without reinforcement in heel stones, sills, lintols, slabs, etc. including moulds, hoisting and fixing in position. 101 102 103 104 105 Grade 20 Grade 25 Grade 30 Grade 40 100mm high heelstone in cement mortar (1:2) to base of door frame (100 x 63mm or 100 x 50mm) including 1 no. 12mm diameter mild steel rod. Hacking through reinforced concrete floors or walls (any thickness) to form opening including making good and remove debris from site. Breaking up existing reinforced concrete structures including removing debris off the site. m3 m3 m3 m3 no 192.40 241.80 251.20 257.80 1.70 m3 m3 m3 m3 305.50 404.90 408.00 414.70 UNIT m2 RATE ($) 18.70

106

m3

339.20

107

m3

77.30

CONCRETING WORK SOR 8 SCHEDULE OF RATES CONCRETING WORK S/N 108 DESCRIPTION Breaking up of existing mass concrete structures including removing debris off the site. Supply and lay a layer of approved epoxy concrete bonding agent to hacked concrete surfaces before concreting. Concrete (Grade 20) in small quantities not exceeding 0.15 metre cube including all necessary formwork. Concrete (Grade 25) in small quantities not exceeding 0.15 metre cube including all necessary formwork. Concrete (Grade 30) in small quantities not exceeding 0.15 metre cube including all necessary formwork. Concrete (Grade 40) in small quantities not exceeding 0.15 metre cube including all necessary formwork. Provision of labour, construction equipment and materials for the coring of holes through concrete structure including removal of debris off site :114 115 116 117 118 119 120 121 123 124 25mm diameter x 100 to 200mm depth. 25mm diameter x 201 to 300mm depth. 25mm diameter x 301 to 400mm depth. 32mm diameter x 100 to 200mm depth. 32mm diameter x 201 to 300mm depth. 32mm diameter x 301 to 400mm depth. 50mm diameter x 100 to 200mm depth. 50mm diameter x 201 to 300mm depth. 50mm diameter x 301 to 400mm depth. 75mm diameter x 100 to 200mm depth. no no no no no no no no no no 35.20 40.60 46.70 28.90 36.20 44.60 42.60 52.50 63.80 46.20 UNIT m3 m2 m3 m3 m3 m3 RATE ($) 64.50

109

25.30

110

304.30

111

308.20

112

312.10

113

322.10

CONCRETING WORK SOR 9 SCHEDULE OF RATES CONCRETING WORK S/N DESCRIPTION Provision of labour, construction equipment and materials for the coring of holes through concrete structure including removal of debris off site :- (Contd) 125 126 127 128 129 130 131 132 133 134 135 136 137 138 138 140 141 75mm diameter x 201 to 300mm depth. 75mm diameter x 301 to 400mm depth. 100mm diameter x 100 to 200mm depth. 100mm diameter x 201 to 300mm depth. 100mm diameter x 301 to 400mm depth. 150mm diameter x 100 to 200mm depth. 150mm diameter x 201 to 300mm depth. 150mm diameter x 301 to 400mm depth. 200mm diameter x 100 to 200mm depth. 200mm diameter x 201 to 300mm depth. 200mm diameter x 301 to 400mm depth. 250mm diameter x 100 to 200mm depth. 250mm diameter x 201 to 300mm depth. 250mm diameter x 301 to 400mm depth. 300mm diameter x 100 to 200mm depth. 300mm diameter x 201 to 300mm depth. 300mm diameter x 301 to 400mm depth. no no no no no no no no no no no no no no no no no 57.30 71.10 55.40 75.50 89.70 103.99 133.30 153.60 163.60 194.30 226.20 207.60 158.30 213.40 246.40 338.60 337.10 UNIT RATE ($)

CONCRETING WORK SOR 10 SCHEDULE OF RATES CONCRETING WORK S/N 142 DESCRIPTION Supply and install 25mm diameter brass tube sleeve for gondola suspension cable not exceeding 210mm long complete with removable brass capping screw and welded with 2mm thick brass collar plate including casting into concrete structure. Supply and drive bakau piles minimum 80mm diameter at the larger end including cutting of piles (provision, assembly, and subsequent dismantling and removal of piling equipment measured separately) :143 144 145 Not exceeding 2.00m long. Exceeding 2.00m but not exceeding 4.00m long. Exceeding 4.00m but not exceeding 6.00m long complete with mild steel pipe sleeves. Exceeding 6.00m but not exceeding 8.00m long complete with mild steel pipe sleeves. Providing and assembling of necessary piling equipment to drive any size of BAKAU PILES including all necessary tools and appliances, subsequent dismantling and removal on completion of the work on site. Supply and drive tanalised timber vertical piles inclusive of tools (provision, assembly and subsequent dismantling and removal of piling equipment measured separately), materials and labour for the execution thereof in any ground. The pay length to be measured from the given cut-off level of the pile to the pointed end of the pile (price include mild steel box joint) for the following sizes :148 149 150 151 125x125mm (SWL 14T). 150x150mm (SWL 20T). 175x175m (SWL27T). Supply and fix 4.5mm thick x 450mm long bituminous painted MILD STEEL BOX JOINT to 125x125mm treated timber piles. Supply and fix 4.5mm thick x 450mm long bituminous painted MILD STEEL BOX JOINT to 150x150mm treated timber piles. Supply and fix 4.5mm thick x 450mm long bituminous painted MILD STEEL BOX JOINT to 175x175mm treated timber piles. m m m no 20.70 24.60 34.60 10.90 no no no 3.00 5.20 10.90 UNIT no RATE ($) 68.90

146

no

13.80

147

item

600.00

152

no

12.10

153

no

15.70

CONCRETING WORK SOR 11 SCHEDULE OF RATES CONCRETING WORK S/N 154 DESCRIPTION Providing and assembling of necessary piling equipment to drive any size of Treated Timber Piles including all necessary tools and appliances, subsequent dismantling and removal on completion of the work on site. Labour, instruments and tools to carry out WORKING LOAD TEST on driven treated timber piles. Supply and drive Grade 40 precast reinforced concrete piles including transportation of pile sections and flat or pointed metal shoes; all for the following sizes (provision, assembly and subsequent dismantling and removal of piling equipment measured separately) :156 157 158 159 150 x 150mm (normal working load of 20 tonne). 175 x 175mm (nominal working load of 30 tonne). 200 x 200mm (nominal working load of 40 tonne). 230 x 230mm (nominal working load of 50 tonne). Supply and drive Grade 40 precast reinforced concrete piles including transportation of pile sections and flat or pointed metal shoes; for the following sizes (provision, assembly and subsequent dismantling and removal of piling equipment measured separately) :- (Contd) 160 161 162 260 x 260mm (nominal working load of 65 tonne). 300 x 300mm (nominal working load of 90 tonne). Providing and assembling of necessary piling equipment to drive any size of reinforced concrete piles including all necessary tools and appliances, subsequent dismantling and removal on completion of the work on site. 'Working Load Test' for reinforced concrete piles including provision of kentledge and all labour, instruments and tools to carry out the work. 'Ultimate Load Test' for reinforced concrete piles including supply and drive of pile and kentledge and all labour, instruments and tools to carry out the work. m m item 32.80 40.80 2,900.00 m m m m 21.10 23.70 27.00 29.90 UNIT item RATE ($) 750.00

155

ton

46.00

163

ton

46.00

164

ton

46.00

CONCRETING WORK SOR 12 SCHEDULE OF RATES CONCRETING WORK S/N 165 DESCRIPTION Dynamic testing of piles complete with CAPWAPC Analysis and the submission of all readings and 4 sets of comprehensive reports as directed by SO Representative including the provision of all labour, instruments and tools to carry out the work. Forming of bituminous expansion joint in concrete floors including all necessary formwork and bituminous seal :166 167 168 13mm wide x 75mm deep. 25mm wide x 100mm deep. Forming of 25mm wide expansion joint in cavity with foam plastic infill. Forming of surface channel 150mm wide x 50mm deep on concrete floor slab to fall. 225mm wide (internal) Reinforced Concrete SURFACE DRAIN constructed with 100mm thick sides, 100mm thick bottom and all exposed sides, bottom and arrises rendered smooth in cement and sand mortar (1:3) including all necessary excavation, formwork and lean concrete laid to fall as directed : 170 Grade 25 not exceeding 300mm deep (average) to invert and reinforced with B6 WSF reinforcement. Add to LAST ITEM for the increase in stages of 150mm deep. Grade 40 not exceeding 300mm deep (average) to invert and reinforced with A7 WSF reinforcement :Add to LAST ITEM for the increase in stages of 150mm deep. Extra over 225mm wide reinforced concrete drain for PRECAST CONCRETE INVERT. 225mm wide (internal) Grade 40 precast concrete house drain not exceeding 400mm deep (average) to invert with 100mm thick sides and bottom complete with reinforcement and topping up sides with in-situ concrete including all necessary jointing, excavation, formwork and lean concrete and laid to falls. Add to LAST ITEM for the increase in stages of 100mm deep. m 45.00 m m m2 3.70 9.00 2.40 UNIT item RATE ($) 1,495.00

169

1.00

171 172

m m

14.30 45.10

173 174

m m

14.70 4.10

175

69.60

176

9.60

CONCRETING WORK SOR 13 SCHEDULE OF RATES CONCRETING WORK S/N 177 DESCRIPTION 300mm diameter spun concrete pipes class 'S' to conduit drain not exceeding 1m deep (average) to invert level, laid on hardcore bed and concrete haunching (1:3:6) to all pipe joints including all necessary excavation and formwork. Add to LAST ITEM for the increase in stages of 150mm deep. Supply and install 300 x 300 x 50mm thick precast concrete (Grade 30) drain slab reinforced with D6 fabric reinforcement with 'HDB' lettering cast on the slab. Supply and lay 300 x 300 x 50mm thick polypropylene fibre reinforced vibro-compacted porous concrete slab with cement and 9 or 14mm thick aggregate (1:4) mix for concealed drain. Supply, delivery and installation of 70mm thick prestressed precast concrete planks including all necessary prestressing wires, reinforcement, mould, formwork, labour and materials for jointing, testing accessories and protection, etc. Supply, delivery and installation of 110mm thick prestressed precast concrete planks including all necessary prestressing wires, reinforcement, mould, formwork, labour and materials for jointing, testing accessories and protection, etc. Supply, delivery and installation of precast lightweight concrete partition walls including all necessary reinforcement, moulds, formwork, stacking, hoisting, setting, labour, materials for jointing, testing accessories and protection etc, :183 184 75mm thick. 90mm thick. m2 m2 42.90 43.90 UNIT m RATE ($) 56.20

178 179

m m

1.37 13.30

180

13.70

181

m2

40.90

182

m2

44.85