HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

10.4.5a Release Notes

Part Number: 5697-0973 Tenth edition: June 2011

Legal and notice information Copyright 2009-2011 Hewlett-Packard Development Company, L.P. Copyright 2009-2011 Brocade Communications Systems, Incorporated Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.

Version
10.4.5a

Description
HP StorageWorks B-series Data Center Fabric Manager (DCFM) 10.4.5a is a patch release, which provides a number of fixes since the DCFM 10.4.5 release. All of the features and functionality of DCFM 10.4.0, 10.4.1, 10.4.2, and 10.4.5 are brought forward with this release, including: Support for new hardware Feature enhancements across multiple platforms Integrated SMI DCFM 10.4 added support for the new HP StorageWorks DC SAN Director 64-port 8Gb Fibre Channel Blade, which enables server and fabric consolidation. DCFM 10.4 continues to simplify management of key data center solutions, such as security, virtualization, and converged IP/SAN networks. The following sections provide a summary of the main feature enhancements of the DCFM 10.4 release.

New hardware platforms


DCFM 10.4.0 introduced support for the following new hardware platforms, which carries forward with this release: HP StorageWorks DC SAN Director 64-port 8Gb Fibre Channel Blade Brocade 804 8Gb FC HBA for HP BladeSystem c-Class

New software features


DCFM 10.4.0 introduced support for the following new software features, which carries forward with this release: Management Plug-In for VMware vCenter 4.0. Plug-in is invoked from vSphere client on selection of a tab, displaying the following information from DCFM: VM connectivity information Statistics information Event information Integrated SMI Agent (Professional Plus and Enterprise editions only): Provides the ability to manage both Fabric Operating System (Fabric OS) and M-EOS hardware Integrated into DCFM; includes SMI-only installation option FCoE: Support for HP StorageWorks 2408 FCoE Converged Network Switch in Access Gateway mode

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

Enhancements
B-series OUI support enhancement
In the first half of 2010, a new Organizationally Unique Identifier (OUI) began phasing into B-series platforms. DCFM 10.3.4 initially added support for this OUI. DCFM 10.4.0 and later continues this support. For more information, see New OUI support on B-series platforms on page 11.

FCoE and CEE Management


Support for Startup, running configurations as follows: Save configuration to repository saves both running and startup configurations Copy running configuration to startup configuration within the switch Restore to startup configuration (and reboot option) Replicate to startup configuration

Encryption enhancements
Support for hosting disk and tape containers on same encryption engine Support for Access Gateway mode in Encryption SAN Switch Usability enhancements: Disk LUN View Edit Smart Card dialog box BP (Blade Processor) Link Configuration Display BP Link Status Dynamic view update on Encryption Center and LUN dialog box Provide commit state on target container Show all rekey sessions for LUN on view Export Certificate support

FCIP enhancements
Support for IPSec for the HP StorageWorks 1606 Extension SAN Switch and the HP StorageWorks DC SAN Director Multiprotocol Extension Blade Support for IPv6 on 1G and 10G ports VEX support on 1G and 10G ports Support for VLAN tagging introduced in Fabric OS 6.3.1 Additional Enhancements: Disable Min/Max bandwidth text fields for unsupported platforms Suggest button displays appropriate message when selected for unsupported platforms Refresh the information in DCFM immediately upon successful FCIP configuration

Virtualization
Support for vSphere 4.0 (ESX 4.0 hypervisors) for monitoring Virtual Machine (VM) icon change in the device tree and topology

Port icon and Host enclosure used for source and destination columns in the End-to-End monitor and Top Talkers dialog box VM Path discovery for File System of type VMFS (Virtual Machine File System)

HBA Management
Updates to Property Sheets, including Remote Port (for example, Speed, Bind Type, Target ID, Vendor), add NWWN property in HBA port properties.

Other enhancements
Accept changes summary dialog box added Event Policies dialog box is enhanced to pass event parameters to script in Launch script action Call Home changes: HP Modem call home centers removed HP LAN port number may now be customized SMTP over SSL is introduced for email-based call home centers Export option in the Port Mapping dialog box Overall security enhancements to application Support for authenticated SMTP over SSL Display of SNMP/ Syslog/ Internal FTP port status display

Ability to export the topology as an image Incremental support for Traffic Isolation Zoning Limited support for Admin Domains: Physical Fabric (AD 255 context) Discovery Asset & Fabric (Nameserver, Topology) information collected in Physical Fabric context Defined and Active Zone configuration is collected in AD 0 context Switch Configuration, Firmware Management, Performance Monitoring, Basic Switch Configuration operations (switch enable/disable, port enable/disable) Implemented the following end user Requests For Enhancements (RFEs): Switch SS folder name change as <Switch name> <Switch IP> <Switch WWN> Copying switch/host support saves to another ftp server through the View Repository dialog box Port group reordering Server/client memory restriction in Options dialog box ASM bit changes for PDCM List zone members enhancement Offline zone db activations Filter ICL ports in Zoning dialog box Zone member rendering in Zoning dialog box Delete button in VF dialog box Inheriting the fabric properties Port unbind Unassigned port address Addressing mode changes in VF dialog box

Support for new Fabric OS features :

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

Enhanced TI zones support Exchange based routing for lossless DLS HP StorageWorks DC SAN Director Switch Multiprotocol Extension Blade support in VF dialog box

Supported switches and firmware


Table 1 lists switches and firmware families supported with version 10.4.5a. This does not imply that all firmware versions listed in the left column are still supported by HP, but rather that those are the firmware streams on which the corresponding switches are, or were, supported. It also does not imply that all the firmware listed in streams are supported on each of the corresponding switches. HP recommends using the latest software versions to get the greatest benefit from the SAN.

Table 1 Supported switches and firmware Switch firmware


Fabric OS 5.0.x, 5.1.x, 5.2.x, 5.3.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, and 6.4.x

Switch/Director
HP StorageWorks SAN Switch 2/32 (Brocade 3900) HP StorageWorks SAN Switch 2/8V (Brocade 3250) HP StorageWorks SAN Switch 2/16V (Brocade 3850) HP StorageWorks SAN Switch 4/32 (Brocade 4100) HP StorageWorks 400 Multi-Protocol Router (Brocade 7500)1 HP StorageWorks 4/8, 4/16 SAN Switch (Brocade 200E) HP StorageWorks SAN Switch 4/64 (Brocade 4900)2 HP StorageWorks SAN Switch 4/32B (Brocade 5000)3 HP StorageWorks 8/8, 8/24 SAN Switch (Brocade 300)4 HP StorageWorks 8/40 SAN Switch (Brocade 5100)4 HP StorageWorks 8/80 SAN Switch (Brocade 5300)4 HP StorageWorks Core Switch 2/64 (Brocade 12000) HP StorageWorks SAN Director 2/128 (Brocade 24000) HP StorageWorks 4/256 SAN Director (Brocade 48000) HP StorageWorks 4/256 SAN Director 16 Port 4Gb Blade (FC4-16) HP StorageWorks 4/256 SAN Director 32 Port 4Gb Blade (FC4-32) HP StorageWorks 4/256 SAN Director 48 Port 4Gb Blade (FC4-48)2 HP StorageWorks iSCSI Director Blade (FC4-16IP)2 HP StorageWorks Multi-Protocol Router Blade (FR4-18i)1 HP StorageWorks SAN Director 6 Port 10Gb FC ISL Blade (FC10-6)5 HP StorageWorks DC SAN Backbone Director (Brocade DCX)6 HP StorageWorks DC SAN Director 16 Port 8Gb FC Blade (FC8-16) HP StorageWorks DC SAN Director 32 Port 8Gb FC Blade (FC8-32) HP StorageWorks DC SAN Director 48 Port 8Gb FC Blade (FC8-48) HP StorageWorks DC SAN Director 64-port 8Gb FC Blade (FC8-64)7 HP StorageWorks Multi-Protocol Router Blade (FR4-18i) HP StorageWorks DC SAN Director 6 Port 10Gb FC ISL Blade (FC10-6) HP DC Switch Encryption FC Blade (FS8-18)8 HP StorageWorks DC SAN Director Multiprotocol Extension Blade (Brocade FX824)9 HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE1024)9

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

Switch firmware
Fabric OS 5.0.x, 5.1.x, 5.2.x, 5.3.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, and 6.4.x

Switch/Director
HP StorageWorks Encryption SAN Switch8 HP StorageWorks DC04 SAN Director (Brocade DCX-4S)
10

HP StorageWorks DC SAN Director 16 Port 8Gb FC Blade (FC8-16) HP StorageWorks DC SAN Director 32 Port 8Gb FC Blade (FC8-32) HP StorageWorks DC SAN Director 48 Port 8Gb FC Blade (FC8-48) HP StorageWorks DC SAN Director 64-port 8Gb FC Blade (FC8-64)7 HP StorageWorks Multi-Protocol Router Blade (FR4-18i) HP StorageWorks DC SAN Director 6 Port 10Gb FC ISL Blade (FC10-6) HP DC Switch Encryption FC Blade (FS818)8 HP StorageWorks DC SAN Director Multiprotocol Extension Blade (Brocade FX824)9 HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE1024)9 HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000)11 HP StorageWorks 1606 Extension SAN Switch (Brocade 7800)9

Fabric OS 5.2.x, 5.3.x, 6.0.x, 6.1.x, 6.2.x, 6.3.x, and 6.4.x

Brocade 4Gb SAN Switch for HP c-Class BladeSystem (Brocade 4024)12 Brocade 4Gb SAN Switch for HP p-Class BladeSystem (Brocade 4012) HP StorageWorks EVA4400 Embedded Switch Module (Brocade 5410)13 Brocade 8Gb SAN Switch for HP BladeSystem c-Class (Brocade 5480)14

M-EOSc 9.6.x, 9.7.x, 9.8.x, and 9.9.x

HP StorageWorks Director 2/64, 2/140 (Brocade M6064 and M6140) HP StorageWorks Edge Switch 2/16 (Sphereon 3216) HP StorageWorks Edge Switch 2/32 (Sphereon 3232) HP StorageWorks Edge Switch 2/12 (Sphereon 4300) HP StorageWorks Edge Switch 2/24 (Sphereon 4500) Sphereon 4400 (Brocade 4400) Sphereon 4700 (Brocade 4700)

M-EOSn 9.6.x, 9.7.x, 9.8.x, and 9.9


1 2 3 4 5 6 7 8 9

Intrepid 10000 Director (Brocade Mi10K)

Requires Fabric OS 5.1.0 or later. Requires Fabric OS 5.2.0 or later. Requires Fabric OS 5.2.1b or later. Requires Fabric OS 6.1.0a or later. Requires Fabric OS 5.3.0 or later. Requires Fabric OS 6.0.0b or later. Requires Fabric OS 6.4.0a or later. Requires Fabric OS 6.2.0b or later. Requires Fabric OS 6.3.0 or later. Requires Fabric OS 6.2.0a or later. Requires Fabric OS 6.1.2_cee1 or later. Support for this switch in DCFM 10.1.x is for discovery only. Requires Fabric OS 5.3.1 or later. Requires Fabric OS 6.1.0_8e or later. Requires Fabric OS 6.1.0_8e1 or later.

10 11 12 13 14

Supported operating systems


Table 2 lists the operating systems that support DCFM 10.4.5a. Table 2 Supported operating systems Operating system
Windows

Versions
XP Professional SP3 (x86 32-bit) 2003 Server SP2 (x86 32-bit) Vista Business Edition SP1 (x86 32-bit) 2008 Server (x86 32-bit) Windows 7 Professional Edition

Solaris Linux

10 (SPARC platform) Red Hat AS 4.0 (x86 32-bit) Red Hat Enterprise Linux 5 Advanced (x86 32-bit) SUSE Linux Enterprise Server 10 SP1 (x86 32-bit)

VMware

VMware ESX 3.5 with Guest VMs of: Windows Server 2003 Std SP2 (x86 32-bit) Red Hat Enterprise Linux 5 Adv (x86 32-bit) SUSE Linux Enterprise Server 10 SP1 (x86 32-bit) Windows XP Pro SP3 (x86 32-bit) Windows Vista Business Edition SP1(x86 32-bit) Windows 2008 Std (x86 32-bit) RedHat AS 4.0 (x86 32-bit) VMware ESX 4.0 with Guest VMs of: Windows Server 2003 Std SP2 (x86 32-bit) Red Hat Enterprise Linux 5 Adv (x86 32-bit) SUSE Linux Enterprise Server 10 SP1 (x86 32-bit) Windows XP Pro SP3 (x86 32-bit) Windows Vista Business Edition SP1(x86 32-bit) Windows 2008 Std (x86 32-bit) Windows 7 Professional edition RedHat AS 4.0 (x86 32-bit)

Supported feature summary for DCFM


Table 3 lists the DCFM supported features. Table 3 Supported DCFM features Feature
Number of fabrics Type of fabric supported

DCFM Professional
1 Fabric OS

DCFM Professional Plus


4 M-EOS, Fabric OS, Mixed

DCFM Enterprise
24 M-EOS, Fabric OS, Mixed

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

Feature
Number of ports 4-Gb and 8-Gb Switches DC SAN Director 10/24 FCoE Blade/2408 FCoE Converged Network Switch 1606 Extension SAN Switch 4/256 SAN Director DC04 SAN Director Switch HBA Management (HCM) Virtualization support Encryption SAN Switch/Encryption Blade DC Director Switch MP Extension Blade Real time stats1 Historical stats2 DBMS (ODBC & JDBC) Partner software integration
nl

DCFM Professional
1,000 Yes Yes

DCFM Professional Plus


2,560 Yes Yes

DCFM Enterprise
9,000 (Fabric OS); 5,000 (M-EOS/Mixed) Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes No No No

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Role Based Access Control (RBAC)


nl

No

Yes

Yes

FICON DC SAN Backbone Director


nl

No No

No No

Yes Yes

1 2

Real-time stats for GE ports. FC ports, E-E Monitors, and TopTalkers Historical stats for FC ports and E-E Monitors

Important notes
This section provides information that you should consider before using DCFM 10.4.x. See the Data Center Fabric Manager Enterprise, Professional Plus, or Professional User Manual for details on the following notes. These documents can be downloaded from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html Under Support, click HP Support & Documents, and then click Manuals. Under User guide, select the appropriate edition.

10

NOTE: Install DCFM on a dedicated machine that is not running any other server applications, such as another database server.

New OUI support on B-series platforms


The OUI value is part of a Fibre Channel WWN that uniquely identifies the manufacturer of Fibre Channel products. The OUI values assigned to Brocade are used by Fabric OS to validate certain fabric interoperability support, and by DCFM to provide for manageability features. Brocade is near to exhausting the currently assigned OUI/WWN values. Therefore, they will soon be using a new OUI value for WWN assignment. WWNs with the current OUI value are expected to be consumed by mid-2010. Brocade factory shipments of switches after this time will have WWNs that include the new OUI. The new OUI value for Brocade is 00:05:33. For example, a WWN of 10:00:00:05:33:41:5c:c1 uses the new OUI. Beginning with DCFM 10.3.4, and continuing forward with DCFM 10.4.0 and later, DCFM has been enhanced to recognize the new Brocade OUI value to guarantee proper functionality. IMPORTANT: If you have a switch with the new OUI/WWN in the fabric, do not downgrade DCFM to a version earlier than 10.3.4. DCFM versions earlier than 10.3.4 will show such switches as unmanaged.

DCFM cannot manage M-EOSc switches with SNMPv3 enabled


DCFM 10.1.3 or later does not support managing M-EOSc switches with SNMPv3 enabled. If SNMPv3 is enabled on M-EOSc switches, SNMPv1 is disabled automatically. DCFM uses SNMPv1 to manage M-EOSc switches; therefore, the manageability link cannot be established if SNMPv3 is enabled. HP recommends that you use the CLI to disable SNMPv3.

JRE 1.6.0 Update 16 is required


If your system has a JRE version earlier than JRE 1.6.0_16, you must update to JRE 1.6.0 Update 16. You can validate this by executing java version from the command prompt. If the version displayed is 1.6.0_16, you are running the correct version. If your JRE version is earlier than 1.6.0_16, remove JRE and then browse to the DCFM Server IP address to download the correct version, which is bundled with the DCFM server. NOTE: If you installed JRE 1.6.0 Update 16, do not use the Java auto-updater, as this changes the JRE version.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

11

DCFM Professional services do not auto-start on Linux and Solaris


After a restart, DCFM Professional services must be started manually on both Linux and Solaris systems. Otherwise, the DCFM client fails to launch.

Event priority mismatch


Error-level policies are occasionally triggered by warning-level events.

Configdownload fails when the ALL parameter is selected


If you run the configdownload command with the ALL parameter selected to download a configuration from one virtual switch to another virtual switch and the Fabric IDs do not match, the download fails.

Switch name update delay


If you use a tool other than DCFM to change the name of a switch, the new name for the switch can take up to 15 minutes to appear in DCFM. The actual time delay depends on the SAN Size value.

Event-based file actions fail


DCFM event actions fail to run scripts on Windows remote-mounted file systems.

EX_Port disabled when configuring routing domain IDs


After selecting an edge fabric and launching the Routing Domain IDs dialog box, if you select all front domains and Xlate domains, and then add domain IDs, clicking OK disables the EX_Ports and displays the following message: EX_PORT ISOLATE

Removing switches
If you plan to segment and remove more than two switches from a fabric, and you have Historical Performance Collection enabled, HP recommends that you accept changes after each switch segmentation from the client.

DCFM clients
To free up server resources and as a best practice, HP recommends that you shut down clients that are not actively being used. In some scenarios, if duplicate entries are displayed in the Product List, restart the client.

Secure Fabric OS fabrics cannot be discovered from DCFM


DCFM does not support Secure Fabric OS (SFOS). If you attempt to discover an SFOS fabric, DCFM displays the message Discovery Failed. To recover, you must remove the SFOS settings and set typical fabric settings.

12

Performance Data Aging tab has been removed from Server Management Console
You cannot configure the Performance Data Aging settings in DCFM 10.1.4 or later. The tab has been removed from the Server Management Console (SMC). The default configuration settings are as follows: 288 samples in a 5-minute period 144 samples in a 30-minute period 84 samples in a 2-hour period 90 samples in a 1-day period 606 total samples

When migrating from an earlier release to DCFM 10.4.0, all historical data is truncated with respect to the default samples, and the aging configuration is not migrated.

Encryption configuration has limited support


The current commit limitation of a total of 25 LUN transactions (add, update, and remove) can cause delays in registering changes for LUN provisioning. To avoid this situation, HP recommends that you commit each transaction before making additional changes.

IFL connection shown in topology after deleting all the VE-VEX tunnels present between the HP StorageWorks 1606 Extension SAN switches
After deleting all the VE-VEX tunnels present between the 1606 Extension SAN switches, a rare instance has been seen where the IFL connection was still shown in topology. HP recommends that you unmonitor and monitor the switch again if this occurs.

F_Ports connected to Access Gateway are not shown as attached ports under the switch
If Access Gateway is connected to the switch, F_Ports connected to access gateway are not shown as attached virtual ports under the switch. HP recommends that you launch a new client.

Empty LAG creation


If a dot1x-enabled port is assigned to an LAG, an empty LAG is created. NOTE: If a two-port combination of dot1x-enabled and dot1x-disabled are added to an LAG, only the dot1x-disabled ports are added to the LAG. HP recommends that you verify the dot1x status on the port before assigning it to an LAG.

Connection between the Access Gateway and switches does not appear when F_Port trunking is enabled on the Access Gateway
If a switch configured with F_Port trunking is connected to the Access Gateway, the F_Port trunk group icon does not appear in the Product Tree, and the connection between the switch and the Access

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

13

Gateway is not displayed in the Topology. HP recommends that you disable F_Port trunking on the switch before connecting it to the Access Gateway.

VMware firewall settings may require HCM agent to be restarted


If the firewall settings on port 514 changed in VMware, the HCM Agent must be restarted. VMware (ESX 3.5 & 4) blocks the Syslog outgoing port 514 by default. If you are using a Syslog Host configuration or HCM as part of DCFM, the firewall must be configured to allow outgoing port 514 for Syslog. Use the command esxcfgfirewall -o 514,udp,out,syslog to open port 514 and the command esxcfgfirewall -c 514,udp,out,syslog to block outgoing traffic through port 514.

HP StorageWorks DC SAN Director support in Professional Plus


DCFM Professional Plus edition can discover, but not manage, the HP DC SAN Backbone chassis. To manage the device, launch the device Element Manager from the Connectivity Map. The HP DC SAN Backbone Director cannot be used as a seed switch.

Uninstalling ODBC DCFM install location


With DCFM 10.0.x and later, when ODBC is installed in the DCFM install location, uninstalling ODBC will not remove the odbc folder from the DCFM location and the ODBC driver shortcut menu item will not be removed. HP recommends that you remove it manually.

Configuring OBDC connection manually


With DCFM 10.0.x and later, when the configuration page is skipped during ODBC installation, you can create DSN at a later time by accessing install home \odbc\createdsn.bat

Failover restriction in mixed fabrics


In mixed fabrics, the seed switch must be a Fabric OS switch. You cannot change the seed switch to EOS manually. In this situation, to manage the fabric with EOS as the seed switch: 1. 2. 3. Disconnect the ISL between the Fabric OS and EOS switches. Unmonitor or delete the Fabric OS fabric. Discover the Pure EOS Fabric by providing the EOS seed switch IP address.

Failover (that is, when the seed switch is not reachable, falling back to another switch as seed switch) can occur in the following cases: Fabric OS to Fabric OS switches EOS to EOS switches EOS to Fabric OS switches Fabric OS to EOS switches

FICON Emulation restrictions in FCIP Tunnel configuration


The FICON Emulation tab in the FCIP Advanced Settings dialog allows (requires) configuration of FICON Debug Flags setting to configure any FICON settings. The recommended value for FICON

14

Debug flag should be set to 0x90010 (even though the dialog indicates the supported range of 0x00000000 to 0xFFFFFFFF). Configuring this setting with any other value will interfere with the FICON Tape Write pipelining settings. This is applicable to versions 10.4.0, 10.4.1, 10.4.2, and 10.4.5.

Displaying logical switches


Logical switches that are created through the Logical Switch dialog box are displayed in the existing Logical Switches Panel > Undiscovered Logical Switch list. To ensure that logical switches display properly, discover the new logical fabric.

Device Port update in Topology view


In a Non-VF environment, a device port status update can take from 2 to 30 minutes (based on SAN size) to update in the GUI when all of the following conditions exist: The switches are discovered using SNMPv3. Soft Serial Number (SSN) is configured. EXT MIB is enabled. To ensure that the GUI is updated within 1 to 3 minutes (based on SAN size), disable EXT MIB.

Updating the FTP server table


Use this procedure only when there is a change in the DCFM server IP (System IP) address. It updates the FTP Server IP address with the current IP address. To update the FTP server table with a new IP Address: 1. 2. 3. Browse to DCFM_Home location \db\Sybase Central 5.0.0\win32. Click scjview.exe to launch the DB application. From the menu bar, select Connections > Connect with SQL Anywhere 10. The Connect window opens. 4. On the Identification tab, enter dcfm in the user ID box, password in the password box, and then click OK. The Sybase Central window opens. 5. In the folders pane, select SQL Anywhere 10 > dcfmdb > dcfmdb - dcfm > Tables. A list of tables appears in the right pane. 6. Scroll down the Tables pane and double-click FTP_SERVER. FTP_SERVER information appears in the right pane. 7. 8. 9. In the FTP_SERVER pane, select the Data tab. Right-click the record with TYPE 0 (internal), and select Edit Row. Enter the new IP and press Enter. IMPORTANT: Do not modify any other column. 10. Close the DB Connection, and then close the application.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

15

Changing Password to Database


You are advised to change the default password to the database to prevent unauthorized access. To change the database password: 1. 2. Go to the Install_Home/bin directory and open a command window. Enter the dbpassword, User_Name Password, New_Password Confirm_Password, and then press Enter.

For further details, see the Changing the database user password section in the DCFM User Manual, Chapter 1 Getting Started.

Access Control List display


Access Control lists are not displayed in the ACL tab of the Edit Switch dialog box for a CEE switch with Fabric OS versions 6.3.1 and earlier.

SMI Enumeration issue


Enumeration instance fails for the following classes when DCFM manages an HP StorageWorks 2408 FCoE Converged Network SAN Switch running Fabric OS 6.3.x or earlier, connected to an FDMI enabled CNA: Brocade_EthernetPortLANEndPOint Brocade_EthernetAdminDomainHostedLanEndPoint Brocade_EndpointOfNetworkPipe Brocade_EthernetSwitchHostedLANEndPoint Brocade_InEthernetLogicalNetwork Brocade_LANEndpoint Brocade_PlatformHostedLANEndPoint

Indication Delivery Time


The time to deliver the indication varies, based on the DCFM SAN size selected during installation. If a large SAN size is selected, indication delivery time will be longer.

SNMP Registration
Provider classes may take more time to update the fabric changes if the switches managed in DCFM are not SNMP registered. Since this will cause a delay in indication delivery, all the switches managed in DCFM should be SNMP registered.

Logging for CIMOM


The default logging level is INFO in the integrated Agent. To change the logging level to DEBUG, update the com.brocade category value in cimom-log4j.xml file present in the \conf folder. The log file size and number of log files also can be changed by modifying the file rolling appender parameters in this cimom-log4j.xml file. Logging Level, File size and Number of Log files can be changed by modifying the fields Log Level , File Size , and Number of Files from the configuration Tool through the CIMOM tab.

16

Accept Changes does not remove the plus or minus sign in Topology/Device Tree
The plus and minus signs are not removed in the Topology/Device Tree when Accept Changes is performed after segmenting or merging the switch or end device. HP recommends that you relaunch the client to remove the plus and minus signs.

HP StorageWorks Encryption SAN Switch is not identified as Router when FCR and IR license enabled.
The HP StorageWorks Encryption SAN switch has FCR enabled and integrated routing license applied, but the Router Configuration dialog box does not list it as a router in the Router Configuration dialog box. So the user cannot configure EX_Ports for the Encryption Switch using DCFM.

Error message is not shown for FC Ports when seclevel is set in the switch
Once the switches are discovered and seclevel is set in the switch on launching Realtime Graph dialog box, no error message is shown to the user.

DCFM is not processing the SNMPv3 traps for Access Gateway switches
If the AG switches are registered for SNMPv3 traps and acting as logical AGs, then if there are any changes made from the CLI, the DCFM updates on a lazy polling cycle.

DCFM takes a long time to update CNA connected to an FCoE switch in AG mode
DCFM is taking more time (2 minutes for small SAN, 15 minutes for Medium SAN, and 30 minutes for large SAN) to update the CNA, which is connected to a Brocade 8000 in AG mode. If the AG switches are registered for SNMPv3 traps and acting as Logical AGs, and you make the CNA online from the CLI, the DCFM updates on a lazy polling cycle.

Syslog troubleshooting
If the default syslog port number is already in use, no syslog messages are received from the device. Use one of the following procedures (depending on your operating system) to determine which process is running on the Syslog port and to stop the process: Windows operating systems Finding the process: 1. Open a command window. 2. Type netstat anb | find /i "514" and press Enter. The process running on port 514 displays, for example, UDP 127:0:0:1:514 *:* 3328. Stopping the process: Type taskkill /F /PID "<PID> and press Enter. For example, kill -9 "<3328>" OR 1. Select CTRL + SHIFT + ESC to open Windows Task Manager. 2. 3. Select the Processes tab. Click the PID column header to sort the process by PID.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

17

4.

Select the process you want to stop and click End Process.

Linux operating systems Finding the process: 1. Open a command window. 2. Type netstat nap | grep 514 and press Enter. The process running on port 514 displays, for example, UDP 0 0 ::ffff:127:0:0:1:514 :::* 27397. Stopping the process: Type kill -9 "<PID> and press Enter. For example, kill -9 "<27397>" Solaris operating systems Finding the process: 1. Open a command window. 2. Type ps ef | grep syslog and press Enter. The process running on port 514 displays, for example, root 27154 1 0 13:49:14 ?. Stopping the process: Type kill -9 "<PID> and press Enter. For example, kill -9 "<27154>".

Installation instructions for installing DCFM 10.4.5


For information about installing DCFM 10.4.5, see the DCFM Migration and Transition Guide or the Data Center Fabric Manager Enterprise, Professional Plus, or Professional user manuals. These documents can be downloaded from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html Under Support, click HP Support & Documents. Under Resources for HP StorageWorks B-series Data Center Fabric Manager Software, click Manuals, and then select the appropriate edition. NOTE: Install the DCFM application on a dedicated machine that is not running any other server applications, such as another database server. Installation instructions are provided for the following operating systems: Microsoft Windows Sun Solaris Linux The DCFM server runs as multiple services on Windows, and as multiple processes on Solaris and Linux; they start automatically after installation. NOTE: DCFM 10.4.5a is a true patch update that requires DCFM 10.4.5 to be already installed. If you have already installed DCFM 10.4.5 and wish to install the DCFM 10.4.5a update, see section on Instructions to apply the DCFM 10.4.5a patch update.

18

Migrating from an earlier version


You can migrate directly to DCFM 10.4.5 Enterprise from DCFM 10.1.x, 10.3.x, 10.4.1, or 10.4.2 Enterprise. EFCM 9.6.x/9.7.x, or Fabric Manager 5.4/5.5 users must upgrade to DCFM Enterprise 10.1.2 or later before upgrading to DCFM Enterprise 10.4.5. For more data migration and installation information, see the DCFM Migration and Transition Guide.

Installation procedures
To install DCFM Enterprise, Professional Plus, or Professional on a Windows server: 1. Download and extract the zip file from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html 2. 3. 4. 5. 6. 7. Under Support, click HP Support & Documents, and then click Download drivers and software. Under Select your product, select HP StorageWorks B-series Data Center Fabric Manager Enterprise Software. Under Select operating system, click Cross operating system (BIOS, Firmware, Diagnostics, etc), and then select your product. Navigate to the Windows folder. Execute install.exe. Follow the wizard instructions to complete the installation.

To install DCFM Enterprise, Professional Plus, or Professional on a Linux server: 1. Download and extract the tar.gz file from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html 2. 3. 4. 5. 6. 7. Under Support, click HP Support & Documents, and then click Download drivers and software. Under Select your product, select HP StorageWorks B-series Data Center Fabric Manager Enterprise Software. Under Select operating system, click Cross operating system (BIOS, Firmware, Diagnostics, etc), and then select your product. Navigate to the Linux folder. From the File Manager window, execute Install.bin. Follow the wizard instructions to complete the installation.

To install DCFM Enterprise, DCFM Professional Plus, or DCFM Professional on a Solaris server: 1. Download and extract the tar.gz file from the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html 2. 3. 4. 5. 6. Under Support, click HP Support & Documents, and then click Download drivers and software. Under Select your product, select HP StorageWorks B-series Data Center Fabric Manager Enterprise Software. Under Select operating system, click Cross operating system (BIOS, Firmware, Diagnostics, etc), and then select your product. Navigate to the Solaris folder. Execute Install.bin.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

19

7.

Follow the wizard instructions to complete the installation.

Applying the DCFM 10.4.5a patch update


Before installing This process assumes you are applying this patch to DCFM 10.4.5. If you are running an earlier version of DCFM, you must upgrade to DCFM 10.4.5 before applying the patch. Shutdown any services that are running. Verify that any old files are appropriately backed up.

Installation instructions
1. Go to the <directory where DCFM is installed>/bin and execute the script patch.bat. NOTE: On windows, DCFM is typically installed in the directory C:\Program Files\DCFM 10.4.5. If that is the location where DCFM is installed on your system, the full path name would be C:Program Files\DCFM 10.4.5\bin\patch.bat. On Unix, DCFM is typically installed at /opt/DCFM_10_4_5. If that is the location where DCFM is installed on your system, the full path name would be /opt/DCFM_10_4_5/ bin/patch.bat.

After you execute the script, the DCFM Upgrade dialog box displays. 2. Click Browse to browse to the patch zip file. Once selected, the Upgrade button becomes enabled. 3. 4. Click Upgrade to apply the patch. As long as there are no services running, the patch is applied successfully. If you did not shutdown services that were previously running, an error message displays and the patch is not applied. If that occurs, stop all services and return to step 3. After the patch is applied, restart the services from the Server Management Console. Verify that the old files are backed up in the patch backup directory in the location where DCFM is installed on your system. Verify that the patch.conf and version.properties files are updated with the applied patch version details. Start the services and verify the new patch version changes are reflected in the About dialog box.

5. 6. 7. 8.

NOTE: The remote client link in the Start menu does not automatically upgrade when you upgrade the Management application. You must clear the previous version from the Java cache. See the user manual procedure, Clearing previous versions of the remote client.

20

Launching the DCFM client


Clear the previous version from the Java cache by executing the procedure Clearing previous versions of the remote client described in the user manual. As noted above, the remote client link in the Start menu does not automatically upgrade when you apply the DCFM 10.4.5a patch. However, when you open the DCFM remote client, the patch version is displayed in the About DCFM dialog box. DCFM Professional client To launch the DCFM client: For Windows and Linux: Double-click the DCFM client shortcut icon on the desktop. For Windows: Select Start > Programs > DCFM 10.4.5 > DCFM 10.4.5. NOTE: For DCFM Professional, the client must run on the same local machine as the DCFM Professional server. DCFM Professional Plus or DCFM Enterprise client To launch the DCFM Professional Plus or DCFM Enterprise client on the same local machine as the DCFM server: For Windows: Select Start > Programs > DCFM 10.4.5 > DCFM 10.4.5 For Linux: The procedure is the same as for launching from a remote host. See the following procedure. To launch the DCFM Professional Plus or DCFM Enterprise client from a remote host:
nl

Open a browser window and enter the DCFM server host name or IP address in the Address box. For example: http://DCFMserverhost1.companyname.com/
nl nl

http://192.x.y.z/ If you specified a DCFM web server port number (other than the default 80) when installing the DCFM server, you must specify the port number after the host name or IP address. In the following examples, 8080 is the web server port number: http:// DCFMserverhost1.companyname.com:8080/ http://192.x.y.z:8080/
nl nl

Installation notes
If you are upgrading from DCFM Professional or Enterprise trial versions, see the procedure in the DCFM Migration and Transition Guide. Ensure that the network environment does not have any firewall protection between the client, server, and switches. If there is a firewall, ensure that rules are set up to enable access. For more information, see the DCFM Administrator's Guide. You must select the SAN size during installation of DCFM 10.4.5a. For more information, see the DCFM Administrator's Guide. If you install DCFM server on a Windows host that has antivirus software, you must disable the antivirus software during the installation. Install DCFM server on a dedicated machine that is not running any other server applications.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

21

DCFM is supported on Windows, Red Hat Linux, and SUSE server guest operating systems that run with VMware ESX 3.5 and 4.0. Other virtualization software is not supported. See Table 2 on page 9. DCFM 10.4.5a was tested using English, Japanese, and German languages and is supported with other non-English Windows operating systems. Most of the displayed text is in English, even though message strings and dates can be displayed in a local language. DCFM 10.4.5a cannot run on the same host as EFCM, FM, or older versions of DCFM if they are actively monitoring fabrics.

Management application server running in Windows 2008


By default, when the Windows 2008 Firewall state is set to On, all inbound connections to the host are blocked. To allow clients from other hosts to access the Management application server, you must change the Inbound connections setting to Allow as follows: 1. Select Start > Administrative Tools > Server Manager The User Account Control dialog box opens. 2. 3. 4. Click Continue. Under Security Summary, click Go to Windows Firewall. Click Windows Firewall Properties. The Windows Firewall with Advanced Security dialog box opens. 5. Based on the Active Profile for your configuration, on the Inbound connections list, select Allow. NOTE: Windows Firewall with Advanced Security supports separate profiles (sets of firewall and connection security rules) for computers that are members of a domain, or connected to a private or public network. Once the Allow option is selected in the Inbound Connections drop-down list, you can launch the client to the server running on a 2008 host. For more information about Windows Firewall with Advanced Security, see the Windows Firewall with Advanced Security Getting Started Guide, at: http://technet.microsoft.com/en-us/library/cc748991(WS.10).aspx 6. Click OK to save the change. You are now able to launch the client to the server.

Launching the client from Windows 2008 host to Management application server
By default, Internet Explorer Enhanced Security Configuration (IE ESC) is enabled in Windows 2008. If you attempt to launch client from the 2008 host to another host in which the Management application server is running, the following warning message appears: You are attempting to download a file from a site that is not part of your Trusted Sites and that may be different from the Web site you are viewing. To download the client, click Add to add the site (Server IP) on which the Management application server is running.

22

If you do not want to see the warning message again, disable the IE ESC as follows: 1. 2. 3. 4. 5. 6. 7. Close all instances of Internet Explorer. Select Start > Administrative Tools > Server Manager. On the User Account Control dialog box, click Continue. Under Security Summary, click Configure IE ESC. Under Administrators, click Off. Under Users, click Off. Click OK.

Documentation updates
For the most recent DCFM documentation, see the following HP website: http://h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html Under Support, click HP Support & Documents, and then click Manuals.

DCFM Installation Guide (Publication Number 53-1001817-01)


On page 10, in the Client and server system requirements section, edit the supported clients as follows: DCFM has the following client and server system requirements: Professional Edition A single server supports a single client (local client only). Professional Plus Trial A single server supports a maximum of 8 clients (local or remote). Professional Plus Edition A single server supports a maximum of 8 clients (local or remote). Enterprise Trial A single server supports a maximum of 8 clients (local or remote). Enterprise Edition A single server supports a maximum of 8 clients (local or remote).

DCFM Migration Guide (Publication Number 53-1001776-01)


On page 10, in the Client and server system requirements section, edit the supported clients as detailed above for the Installation Guide.

Brocade document: DCFM Professional User Manual (Publication Number 53-1001773-01)


On page 47, in the Host discovery section, edit the Configuring virtual machine credentials procedure as follows: 1. Select Discover > Setup. The Discover Setup dialog box opens. 2. Click Add Host. The Add Host Discovery dialog box opens. 3. Specify the hosts for discovery. To discover a host, refer to Discovering Hosts by IP address or hostname on page 42, Importing Hosts from a CSV file on page 43, or Importing Hosts from a Fabric on page 44.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

23

4. 5. 6. 7. 8. 9.

Click the Host Credentials tab. Select Discover Brocade HBAs in the hosts check box. Enter the HCM Agent port number in the Brocade HBAs - Port field, if necessary. Enter your username and password in the appropriate fields. Select the Discover Virtual Machine information in the hosts check box. Enter the virtual machine port number in the Virtual Machines - Port field, if necessary.

10. Enter your username and password in the appropriate fields. 11. Click OK on the Add Host Discovery dialog box. If an error occurs, a message displays. Click OK to close the error message and fix the problem. A Host Group displays in the Discovered Addresses table with pending status. To update the status from pending you must close and reopen the Discover Setup dialog box. 12. Click Close on the Discover Setup dialog box.

Brocade document: DCFM Professional Plus User Manual (Publication Number 53-1001774-01)
On page 27 and 28, in the Supported hardware and software section, change the footnote number 14 after the hardware name to 13. On page 51, in the Host discovery section, edit the Configuring virtual machine credentials procedure as detailed above for the Professional User Manual. On page 170, in the SMI Agent configuration section, add the following information:

Service Location Protocol (SLP) support


The Management application SMI Agent uses Service Location Protocol (SLP) to allow applications to discover the existence, location, and configuration of WBEM services in enterprise networks. You do not need a WBEM client to use SLP discovery to find a WBEM Server; that is, SLP discovery might already know about the location and capabilities of the WBEM Server to which it wants to send its requests. In such environments, you do not need to start the SLP component of the Management application SMI Agent. However, in a dynamically changing enterprise network environment, many WBEM clients might choose to use SLP discovery to find the location and capabilities of other WBEM Servers. In such environments, start the SLP component of the Management application SMI Agent to allow advertisement of its existence, location, and capabilities. SLP installation is optional and you can configure it during Management application configuration. Once installed, SLP starts whenever the Management application SMI Agent starts.

Management application SMI Agent SLP support includes the following components:
slpd script starts the slpd platform. slpd program acts as a Service Agent (SA). A different slpd binary executable file exists for UNIX and Windows systems. slptool script starts the slptool platform-specific program. slptool program can be used to verify whether SLP is operating properly or not. A different slptool exists for UNIX and Windows.

24

By default, the Management application SMI Agent is configured to advertise itself as a Service Agent (SA). The advertised SLP template shows its location (IP address) and the WBEM Services it supports. The default advertised WBEM services show the Management application SMI Agent: Accepts WBEM requests over HTTP without SSL on TCP port 5988 Accepts WBEM requests over HTTPS using SSL on TCP port 5989

slptool commands
Use the following slptool commands to determine whether the SLP is operating properly. slptool findsrvs service:service-agent Use this command to verify that the Management application SMI Agent SLP service is properly running as a Service Agent (SA). Example output: service:service-agent:// 127.0.0.1,65535. slptool findsrvs service:wbem Use this command to verify that the Management application SMI Agent SLP service is properly advertising its WBEM services. Example outputs: service:wbem:https:// 10.0.1.3:5989,65535 and service:wbem:http://10.0.1.3:5988,65535. This output shows the functionalities of Management application SMI Agent: Accepts WBEM requests over HTTP using SSL on TCP port 5989 Accepts WBEM requests over HTTP without SSL on TCP port 5988 slptool findattrs service:wbem:https://<IP_Address:Port> Use this command to verify that Management application SMI Agent SLP service is properly advertising its WBEM SLP template over the HTTP protocol. Example output: slptool findattrs service:wbem:http://10.0.1.2:5988 NOTE: IP_Address:Port is the IP address and port number that display when you use the slptool findsrvs service:wbem command. slptool findattrs service:wbem:https://IP_Address:Port Use this command to verify that the Management application SMI Agent SLP service is properly advertising its WBEM SLP template over the HTTPS protocol. Example output: slptool findattrs service:wbem:https://10.0.1.2:5989

SLP on UNIX systems


This section describes how to verify the SLP daemon on UNIX systems. SLP file locations on UNIX systems: SLP logManagement_Application/cimom /cfg/slp.log SLP daemonManagement_Application/cimom /cfg/slp.conf You can reconfigure the SLP daemon by modifying this file. SLP registerManagement_Application/cimom /cfg/slp.reg You can statically register an application that does not dynamically register with SLP using SLPAPIs by modifying this file. For more information about these files, read the comments contained in them, or go to http://www.openslp.org/doc/html/UsersGuide/index.html.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

25

Verifying SLP service installation and operation on UNIX systems To verify: 1. 2. 3. Open a command window. Type % su root and press Enter to become the root user. Type # Management_Application/cimom/bin/slptool findsrvs service:service-agent and then press Enter to verify the SLP service is running as a Service Agent (SA). Type # < Management_Application >/cimom/bin/slptool findsrvs service:wbem and then press Enter to verify the SLP service is advertising its WBEM services. Choose one of the following options to verify that the SLP service is advertising the WBEM SLP template over its configured client protocol adapters: Type # Management_Application/cimom /bin/slptool findattrs service:wbem:http://IP_Address:Port and press Enter. Type # Management_Application/cimom /bin/slptool findattrs service:wbem:https://IP_Address:Port and press Enter. NOTE: IP_Address:Port is the IP address and port number that display when you use the slptool findsrvs service:wbem command.

4. 5.

SLP on Windows systems


This section describes how to verify the SLP daemon on Windows systems. SLP file locations on Windows systems: SLP logManagement_Application\cimom \cfg\slp.log SLP daemonManagement_Application\cimom\cfg\slp.conf You can reconfigure the SLP daemon by modifying this file. SLP registerManagement_Application\cimom\cfg\slp.reg You can statically register an application that does not dynamically register with SLP using SLPAPIs by modifying this file. For more information about these files, read the comments contained in them, or go to http://www.openslp.org/doc/html/UsersGuide/index.html. Verifying SLP service installation and operation on Windows systems To verify: 1. 2. 3. 4. 5. Launch the Server Management Console from the Start menu. Click Start to start the SLP service. Open a command window. Type cd c:\Management_Application\cimom \bin and press Enter to change to the directory where slpd.bat is located. Type > slptool findsrvs service:service-agent and press Enter to verify the SLP service is running as a Service Agent.

26

6. 7.

Type > slptool findsrvs service:wbem and press Enter to verify the SLP service is advertising its WBEM services. Choose one of the following options to verify the SLP service is advertising the WBEM SLP template over its configured client protocol adapters. Type > slptool findattrs service:wbem:http://IP_Address:Port and press Enter. Type > slptool findattrs service:wbem:https://IP_Address:Port and press Enter. NOTE: IP_Address:Port is the IP address and port number that display when you use the slptool findsrvs service:wbem command.

DCFM Enterprise User Manual (Publication Number 53-1001775-01)


On page 46, in the Host discovery section, edit the Configuring virtual machine credentials procedure as detailed above for the Professional User Manual. On page 171, in the SMI Agent configuration section, add the Service Location Protocol (SLP) support information as detailed above for the Professional Plus User Manual.

DCFM 10.4.0 fixes


Table 4 lists the fixes that were closed for this release. Table 4 DCFM 10.4.0 closed fixes Closed fixes summary
Blade instances are not returned for M-Model director type switches Physical Package SubProfile: CP Blade Instances were not returned while doing EnumerationInstance operation on Brocade_Blade class. Enumeration, GetInstance and Executive query operations fail for Brocade_Blade and Association/Reference operations fail for Brocade_Blade class with resultant class as Brocade_Port Module. User will not be able to traverse from Blade to Port module class when Fabric OS-based director is used. Instances are not returned for the class Brocade_SwitchFCPorRateStats. User will not be able to traverse from SwitchFCPortRateStats to other classes since no instance was returned. Brocade_LogicalIdentity class is missing under Brocade_Fabric.MOF but available in datamodel; CIM_ERR_NOT_FOUND exception is given if any operations are performed on Brocade_LogicalIentity class. User will get CIM_ERR_NOT_FOUND exception, since LogicalIdentity class is not defined under Fabric MOF.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

27

Closed fixes summary


Trunking: "CIM_ERR_NOT_FOUND" Exception is displayed for the following classes: Brocade_Trunk, Brocade_SwitchFCPortInTrunk, Brocade_NodeFCPortInTrunk,Brocade_TrunkInSwitch. User will get CIM_ERR_NOT_FOUND exception since Trunk-related classes were not implemented. FRU Indication is not received when user performs blade powered on/off for Fabric OS-based and M-EOS-based directors. Brocade_Chassis instance is not returned for switches that are in Unmanageable state. CIMOM server fails to start, leading to user not able to use the SMIAgent. Performance Management Rx/Tx % Utilization is plotted incorrectly for xGE ports in Real Time Graph. Migration process (From installing DCFM 10.3.x to discovering all the switches) takes 35 minutes when migrating from DCFM 10.1.x with 13 Firmwares in repository and 3MB Zones files. PDCM: Configuration fails to load when switch username and password is changed. A seed switch converted into an Access Gateway does not become unmonitored when another switch in that fabric is discovered. This leads to other members of the fabric getting marked as missing; this fabric was allowed to be monitored using a different switch. Call Home: Call Home dialog box is blank after creating virtual switch in Mi10k which is connected with two Fabric OS Virtual switches. Scalability: Connections are not shown properly in the topology for the Access Gateways. M-EOS discovery: Accept changes is not working for the pure EOS fabric, leading to user not being able to get the current status of the fabric. All fabrics no longer shown when switching to a one fabric view and then back to view all. LSAN Zoning; Activated LSAN zone is not shown in the LSAN Zoning dialog box after reopening the dialog box Backend error is being displayed on creating a Profile/Map on the HP StorageWorks 2408 FCoE Converged Network switch or DC SAN Director Switch 10/24 FCoE blade. Unable to replicate the All Configurations from one 2408 FCoE switch to a different 2408 FCoE switch.

Solution

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Workaround prior to upgrade: Re-login to client. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Wait for 15 to 30 minutes. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

28

Closed fixes summary

Solution
Workaround prior to upgrade: Delete the newly discovered host - Monitor the old fabric - Delete and rediscover the host. Fixed in DCFM 10.4.0.

Host and storage connected to a fabric are shown isolated in the Host view when Host is rediscovered because of HCM agent connection failure.

Clientsupportsave.sh file fails to execute in Solaris and shows syntax error. Port Fencing: Port Fencing dialog box opens with a blank tree and Null pointer exception reported in client log. Unable to restore the FC configuration to 2408 FCoE switch. Activating the IPL PDCM configuration fails with DCFM with error "PDCM_002 :Unknown error, Cannot set CUP Configuration". Client lost connection to server on both Linux and Solaris server overnight. Help dialog box is not launched for encryption system cards. PAD: Unable to unblock a automatically disabled port from PAD dialog box. Installation: With the Professional edition, user is able to select the Server IP in the Server IP Configuration page and hence remote client can be launched by copy and pasting the link in the browser. Remote client closed abruptly. Port Fencing: Unblocking action for chassis based switches is not working in Port Fencing. HBA's WWN name is periodically changing on product list. For Chassis based switches, some of the Logical switches are not gaining the manageability, and will be marked with the construction symbol. PDCM: Activating a user configuration with port names configured does not set the port names in switch. Able to launch historical graph/report in Professional edition through FCIP Tunnel dialog box and CEE Configuration dialog box, even though this is not supported for Professional. Server is not started in DCFM 10.3.1 EE, while doing remote migration from DCFM 10.3.0 EE. In Firmware Repository tab, two radio buttons that show "All Supported Switch types" and "Switch types in particular group" are missing under "Supported Switch Type Information" table in Professional plus Edition.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Re-launch the Port Fencing dialog box. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Use CLI to unblock the port. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Unblock the port from CLI. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

29

Closed fixes summary


SNMPv3 SHA authentication used in switch discovery fails,

Solution
Fixed in DCFM 10.4.0. Workaround prior to upgrade: User able to take switch schedule backup daily. Fixed in DCFM 10.4.0.

Unable to configure switch Scheduled backup for weekly/monthly when the regional settings in the system are changed

LDAP Auth : Fall back authentication is not working when we select the reachable LDAP server to be last (third) in the list of configured LDAP servers. Zoning: Not able to add members using Add Zone Member dialog box and exception is given in the client. Error message displaying as "Firmware could not be imported into repository when importing 5.x firmware into Firmware repository of Firmware Management dialog box. FCIP: GE ports of Multiprotocol Router Blade is not displayed in FCIP Tunnels dialog box due to absence of slot based license which is not required for those blades. FCIP Deleting the Tunnel from FCIP dialog box does not remove IP interfaces of the circuits in the Switch, leading to the user being unable to create a new tunnel with the deleted IP addresses. Port List on Mi10k Element Manager is not updating after the port is blocked via RMC. Firmware upgrade via the Element Manager on a M4700 never completes (according to the Send Firmware dialog box). Zoning: When normal zone and a TI zone is activated only the TI zone is shown as Active and the Active Zone configuration is not shown Fault Management Incorrect "Source Name" is displayed in master log event for virtual fabric enabled switches. Zoning: The Redirection zones present in the zone Database vanishes when zoning activation done from DCFM. Web Tools cannot be launched from DCFM 10.3.1 with JRE 1.6.0_14 and later, but DCFM Web Start works fine. Zoning database is empty for McDATA fabric. VM Management: - Unable to discover VM Information from VM Ware Host. Extended data collection on Mi10k is hanging. Configuration changes made to the FCIP tunnel cannot be saved. Edit FCIP Tunnel dialog box is not dismissed when OK button is selected after making changes in the Advanced Settings and hence configuration changes are not saved.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Wait until the Zone collection completes. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

30

Closed fixes summary

Solution
Workaround prior to upgrade: Delete and rediscover all the Fabrics which contain the Logical switches. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Change the port name from the default view (View All)/ delete all unmonitored fabrics. Fixed in DCFM 10.4.0.

VF: Chassis is getting duplicated in Logical Switches dialog box and Topology after unmonitor/monitor the fabric.

Client lost connection to server while doing port name changes

Unable to launch Web Tools from DCFM. HP StorageWorks Encryption SAN switch was in an Encryption Group configured with Key Vault 1 initially but later changed to Key Vault 2 yet 'Management application still shows Key Vault 1 as the key vault. Null Pointer Exception is given in Server Console when Fusion is connected to DCFM10.3.2. Client hangs and DCFM is taking more than 30 minutes to launch the End to End Monitor dialog box in a large fabric with 8640 switchports and 18227 device ports. JBoss Enterprise Application Platform Multiple Vulnerabilities. CNA logged into 2408 FCoE switch is not shown in Fabric Tree. If user has the latest OUI valued switch discovered in DCFM 10.3.3, after migrating to 10.3.4, the switch is not manageable.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Delete and rediscover the fabric. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Rediscover the fabric. Fixed in DCFM 10.4.0.

In Migrated server the Call home status is disabled for New OUI switches Four HP StorageWorks 4/256 SAN directors with Multiprotocol Router blades are not populating DCFM with events logs and LSAN zoning greyed out. IM2 fabrics should be filtered in Cascaded FICON Fabrics Merge wizard, but are not, which allows the user to proceed with the wizard. SYR files not getting generated. Topology: Disabling a port does not update the topology (more than 15 minutes) for Non VF capable switch which is discovered through SNMPv3. Properties: Serial #/supplier Serial # should be shown instead of RNID Sequence Number in the Switch Properties dialog box. Fault Management: Description is blank for the Master Log event that is generated for enabling Logical Fabric. Authentication fails at client login when the user name is separated by period (.) character.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

31

Closed fixes summary


DCFM schedule backup drifts. Customer is seeing the back drift over time from the time he set. Over three days, it drifts more than a minute. Customer reported that this continues through the month.

Solution
Fixed in DCFM 10.4.0. Workaround prior to upgrade: The trap forwarding issue occurs only when the client IP matches the trap recipient IP, the workaround would be to try on a different client IP. Fixed in DCFM 10.4.0.

Trap forwarding not allowing IP address addition. User is not able to add the IP address of a machine in which the client is running.

FICON: Configure Cascaded FICON Fabric dialog box hangs while setting FICON parameters and enabling FMS mode for IM2 Fabric.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Launch the remote client from the browser instead of just clicking on the old short cut menu icon. This will update the short cut menu version. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Rediscover the Fabric. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Remote client from 10.0.x is unable to upgrade automatically to 10.1.x.

Access Gateway to switch connection is not shown after the Fabrics are merged Cannot open discovery or see active zone config after upgrade from EFCM 9.7.3 to DCFM 10.3.0. Minimum bandwidth should be 10 MB/s for the tunnels created in HP StorageWorks 1606 Extension SAN switch and DC SAN Director Multiprotocol Extension blade. No privileged user for Zoning Online alone able to launch a Zoning dialog box but after some time, the Online Zone DB column becomes empty and not able to operate Zoning dialog box.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Change the SAN Size to Medium and then to Large in the Option dialog box. Fixed in DCFM 10.4.0. Workaround prior to upgrade: 1. User can launch the Zoning dialog box and in the listed scope select the LSAN zoning scope. 2. Unmonitor and monitor the Backbone fabric. Fixed in DCFM 10.4.0.

Connection Pool Size values are not migrated from EFCM correctly for Large SAN, leading to slow client responsiveness.

LSAN Zoning menu item is grayed out when using 4/256 Director with Multiprotocol Router blade as the backbone fabric.

In Zoning report, Logged in status is shown as No for online E_Ports. Port Fencing: After migration from EFCM 9.7.4 to DCFM 10.3.0 the FC address column is disappearing and the data for FC address is coming under the threshold name.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

32

Closed fixes summary


Virtual Session Port Properties dialog box is launched instead of CNA Port Properties dialog box on selecting the port on CA. When a Fabric OS switch is in a EOS Fabric, the Fabric OS switch must be used as the seed switch. If the Fabric OS seed switch goes unreachable, user will not be able to manage the fabric. Email Event Notification All the SAN alert events are not sent consistently to the configured Email ID for a user.

Solution
Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close the loaded configuration files before closing the Configure Allow/Prohibit Matrix or reload the configuration files. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close the FCIP Tunnel dialog box and open it after some time. Values will then be updated. Fixed in DCFM 10.4.0

Port Order is not in correct sequence when Configure Allow/Prohibit Matrix window is reopened after loading a Port Group in Right Hand Side.

After adding the new circuit in the Circuits TAB between the 1606 extension SAN switch or multiprotocol blade, some fields are shown as EMPTY for the newly added circuit.

DCFM cannot configure D,I Zone an Mi10K configured for 239 DIDs. Error message states D,I zoning is not supported. After creating a new tunnel, tunnel has not been shown at the Switch2 side. It has been shown only after relaunching the FCIP Tunnel dialog box. Online Help page titled About User privileges does not have detail about Switch save, Restore, Schedule backup and "Upload Failure Data Capture" in Technical Support Data Collection.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Re-launch the FCIP Tunnel dialog box. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Restart the client. Fixed in DCFM 10.4.0.

User defined names for end devices sometimes disappear in the client.

DCFM launch scripts: Configuration of launch script utility within DCFM event monitoring not behaving as designed.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Manually find the pages in online help. Fixed in DCFM 10.4.0.

Incorrect help page is launched for HBA Port property help and FCIP Edit Tunnel help.

FCIP Tunnel Wizard does not Let User Know Why A port Remains Disabled When There is a Security Violation. Internal Error Observed when the SNMP credentials are modified in Virtual switches. DCFM discovery status reports "Discovered: Not registered for SNMP Traps" for 2/64.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

33

Closed fixes summary

Solution
Workaround prior to upgrade: After restarting DCFM Server Services and all new information are displayed correctly. Fixed in DCFM 10.4.0.

F_Ports connected to Access Gateway are not shown as attached ports under the switch.

Incorrect Domain ID Displayed in Hover Help and Properties dialog box for IM2 fabric. Logical Switch dialog box is blank for the new OUI VF capable switch. Unable to discover the Mi10k partition if one or more unsupported switches are present in the fabric. DCFM 10.1.x Inadequate warning provided before Zone configuration deactivation. DCFM services will not install. When a logical switch is edited through DCFM, the GUI takes a long time to update. In User Management dialog box, EMail Notification column is not sorted correctly when users by ID, Description, EMail Notification, EMail Address fields in Users Panel so that a mismatch occurs in event notification enabled Users. In Add FCIP Tunnel dialog box VEX option got enabled, after adding the circuit with gigE ports of multiprotocol extension blade. In FCIP Tunnel dialog box, Switch-two name was not shown for the tunnels when we add Second side tunnel for the already configured One Side tunnel. SNMP Setup dialog box lists the v3 options when SNMP v1 parameter is selected in the trap forwarding tab. Deletion of circuit through CLI is not updated in the FCIP Tunnels dialog box. Domain Offset is not added to the port address of the M-EOS switches. Not able to login to Linux Client and no window is launched when valid user name and password is entered and exceptions given on the client side. Active client is not logged-out when the corresponding resource group is deleted where the user is assigned. Rename the Selective Ack Off check box as Selective Ack in the FCIP Circuit Advanced Settings dialog box and when the option is checked, Selective Ack should be set On in the circuit and vice versa. Status of the Selective Ack should be displayed as Off/On instead of 0/1 in the Circuit Tab of the FCIP Tunnels dialog box.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close and open the FCIP Tunnel dialog box. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

34

Closed fixes summary


Second switch not compatible with first switch error is given when we select the 4/256 Director with Multiprotocol Router blade as Switch Two, for the DC SAN Backbone Director with Multiprotocol Router blade, which already has "One Side" tunnel. Removing/Adding a TI Zone from DCFM should not affect the Active Zone configs in the switch, but currently disrupts traffic during TI zone config changes. Selective Ack is disabled by default when the Tunnel is created in DCFM , But in CLI, when a Tunnel is created, Selective Ack is enabled by default. In the Help content of Add FCIP Tunnel dialog box, information about Select Switch Two button is missing Configure Storage Encryption Fails When Target Info Entered Without :", and user will not be able to create containers. FICON Emulation settings validation error message pops up in Transmission tab when there are no changes made in the FICON Emulation tab. Node Descriptor "Flag" is not updated in Port Connectivity View dialog box and Refresh operation also does not update the latest data from switch. Error message needs to be modified, which is shown when opening Add FCIP Circuit dialog box, if no FCIP license in the switch. Also error window title is not as per DCFM guideline.

Solution

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: The view will display the fabrics/hosts , if selected from the fabric view. Fixed in DCFM 10.4.0. Workaround prior to upgrade: User can see the alias name in Zoning dialog box. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Relaunch the FCIP Tunnel dialog box, the Circuit dialog box displays with appropriate data. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Restart the client. Fixed in DCFM 10.4.0.

In host view, selecting a view that does not contain any fabric connected to the server, displays a blank view.

Alias name is not getting displayed in the LSAN Zoning dialog box.

Circuit tab displays blank for the newly created single side tunnel

Renaming a host reflects only after client re-launch.

Error message is displayed and report is not generated while activating zone for a pure EOS fabric with report generation enabled.

Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

35

Closed fixes summary

Solution
Workaround prior to upgrade: Check the Committed option and able to create the tunnel Fixed in DCFM 10.4.0.

Unable to create Single side tunnel when Uncommitted is checked in Add FCIP Circuit dialog box.

Auto enclosure is not created in the Fabric view after discovering Host and wrong fabric WWN is shown in the Host view.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Load the configuration in the Right hand side and then activate the configuration. Fixed in DCFM 10.4.0.

Activating a configuration without loading to Right Hand Side (PDCM Matrix) fails and NPE is thrown in the Client.

Fault Management : Master log event count is incremented with the old source name even when the switch name is changed. Seed Switch failover does not happen to Switch 3 in pure EOS fabric as DCFM does not release the NMRU link of Switch 2.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: By removing the Extra entry of WWN from the Zones table, user can activate the Zone configuration Fixed in DCFM 10.4.0. Workaround prior to upgrade: Select any Fabric or Switch in the Device Tree Fixed in DCFM 10.4.0. Workaround prior to upgrade: Provide all the configured v3 credentials when discovering the switch. Fixed in DCFM 10.4.0.

An additional entry of WWN is being added in the zones table when a CNA is added to a Zone.

View Utilization menu item is disabled in Fabric view when the discovered Host is deleted

Discovery dialog box is not showing the status SNMP communication failed. SNMP credentials may be invalid when the user fails to provide the configured Auth\ priv passwords in DCFM.

Delete of a logical switch failed, server errors about moving port from and to the same FID.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Fill any value in the context name field. - If the correct user name, Auth/Priv protocol and password are set, the trap will be forwarded to the destination. Fixed in DCFM 10.4.0. Workaround prior to upgrade: To get manageability after migration, Go to SNMP tab for Mi10k switch in Edit dialog box and check the "Configure for Intrepid 10k" checkbox. Fixed in DCFM 10.4.0.

When context name field is empty, SNMPv3 trap forwarding is failed.

After migration from 10.1.x Enterprise Edition to 10.3.1 Enterprise Edition, Mi10k is not getting manageability in Mixed fabric if discovered through APIuser in DCFM 10.1.x

36

Closed fixes summary

Solution
Workaround prior to upgrade: Add the double side tunnel between two DC SAN Backbone Director with multiprotocol router blades or two 4/256 Director with Multiprotocol Router blades. You should now be able to configure the tunnel. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close the Configure Allow / Prohibit matrix and open it again. Fixed in DCFM 10.4.0.

After adding single side tunnel on DC SAN Backbone Director with multiprotocol router blade or 4/256 Director with Multiprotocol Router blade, VE port number not shown along with Tunnel ID. Upon adding second side tunnel for that one side tunnel error has been given in FCIP Tunnel\Circuit Configuration Report dialog box.

Copied Configuration is not listed in the Product/port tree but successfully saved in the switch.

Some port fencing policies not applied to the 1606 extension SAN switch. The + sign is shown at the wrong time. The > is shown at the wrong level. An alert message is shown in the Zoning dialog box when the TI zone modification is done before activation. Low disk space error message is shown while trying to import firmware even though 30GB disk space is available in installation directory in Windows Vista OS. Enable informs on a fabric with no informs capable switches hangs, client must be killed.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close and reopen the FCIP Tunnels dialog box and observe that now multiple circuits will not be shown to the user. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Schedule daily backup. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Relaunch the client to see the fabric in Topology. Fixed in DCFM 10.4.0.

Duplicate circuits have been shown in the Circuits TAB of FCIP Tunnels dialog box when multiple circuits for the same tunnel are created.

Unable to configure weekly / monthly switch scheduled backup for the current day with a lesser time than the current system time The image bundled with DVD HTML displays "Professional Edition",this needs to be replaced with the latest image. Installation guide has incorrect system requirements for SUSE Linux. Additional fields are shown in Access Gateway property sheet on AG device 2408 FCoE switch. DC SAN Backbone Director discovery fails intermittently (1 out of 10 times) giving the error message "Discovery Failed.

Fabric disappears in the Client after performing unmonitor and monitor operation in mixed fabric.

Product List: Serial Number is displayed incorrectly for OEM customized switches.

Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

37

Closed fixes summary


Wrong GbE port format has been mentioned in the Delete Progress dialog box, when the tunnel is deleted. Trunked ISL (2 connections) is displayed as single link and trunk status is not updated in the connections table. Appropriate message should be displayed when creating a logical switch with Interop mode 2 and zero based addressing mode and also while editing the switch with this combination. Logical Switches dialog box displays unmonitored chassis. Installer package (DVD) doesnt have the branded documents. DCFM should not poll for IPSec information to the switches that do not support this feature.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Enable the insistent domain id after the creation of logical switch. Fixed in DCFM 10.4.0.

While creating a new logical switch, Insistent Domain ID is not enabled in switch when configured.

Bad error message when merging two IM=2 fabrics. When merging two single switch fabrics, the error message: "Backend error: no change to distribution list" is displayed. Clicked on "Finish" and it appears to have completed the merge OK, but no zones were configured set to allow all access. Event policy, Type ISL Offline, is triggered for the F_Ports. Error message is displayed when valid physical ports from Logical switch is selected for Trace Route operation. Spanning-Tree configurations do not match the CLI commands. Default sort column is incorrect for Configure/CEE dialog box. DCFM allows D,I zoning in logical switches that are configured for zero-based addressing in IM=2. This should not be allowed as it causes frames passed from M-EOS switch back to Fabric OS switch to be dropped. A fresh management application install enables call home centers. Only installing OEMs call home center should be enabled. User with Read Only privilege for Zoning Offline, List Zone member option is disabled and Online Help page titled About User Privileges does not have detail about List Zone member. FICON Emulation values in Advance Settings are not in sync with CLI; that is, CLI shows FICON flag as off, but application displays it as enabled. In Activate Zone Config dialog box, property is not shown for removed TI zones after saving the renamed TI zone by using Ok/Apply/SaveToSwitch in Zoning dialog box.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

38

Closed fixes summary


In Email Event Notification some events are missing in email when Summary Interval is configured for 5 seconds.

Solution
Fixed in DCFM 10.4.0. Workaround prior to upgrade: User has to delete all the zones which contain D,P members from the Global zone Library. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Open a new local client after 5 Minutes. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Wait for a discovery cycle. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: After discovering or creating the view with the fabric or adding the fabric to the view, select the desired sub-option in the Connected devices option. Fixed in DCFM 10.4.0.

After Migration for the Interopmode 3 fabric, user is not able to activate a WWN zone config from the Global zone library if any D,P member is present in different zone configuration.

IP address updated in the remote client is not getting updated in the local client and the switch is also not getting manageability.

Renamed TI zone is shown as active in the active zone configuration tab for Fabric OS 6.2.x. Manageable switch is missing from the FCIP Tunnel dialog box, even though the FCIP collection is completed. Active TI zone is shown with green icon in Compare Merge dialog box for Fabric OS less than 6.3.0. Decimal values are not shown in Historical Report for Tx or Rx %Utilization when it is selected as Main Measure. Different values are shown in Historical Graph and Report for Rx or Tx MB/sec in 30 minutes Granularity.

For a fabric with phantom switch, on discovering the fabric or creating a new view with the fabric or adding the fabric to a view, the Connected end devices is set to hide all, but the phantom switch is shown in device tree.

Syslog unregistration did not happen for Host Deletion in HBA Management. The Virtual devices are counted in the device information area in fabric summary report so that number of Initiator, Target count shown incorrectly. On editing the view name without editing the selected fabrics and hosts, the end devices are hidden in topology, even though show all is still selected. Only Rx Ave MB/sec is shown instead of Tx + Rx Ave (MB/sec) as the column header in Top Talkers dialog box in Fabric mode. Fabric Port Reports Total Port count is adding GigE port count also.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Under Connected end devices , select Hide all and then show all. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

39

Closed fixes summary


On Editing the view, there is a mismatch between the levels set under the Manage view option in View menu and the levels shown in device tree. Flyover is not displayed between the created new storage array and switch. Able to create two or more New servers/Storage arrays with same name as a fabric name and error message is not shown. Created storage array entry persists even after the corresponding fabric is unmonitored. Disconnect button is enabled when there is no selection of active client in Active Session dialog box. If Disconnect is clicked, active client is not removed from the dialog box but actually client is disconnected with no masterlog message. Active TI zone is shown with green icon in Activate Zone Config dialog box for Fabric OS less than 6.2.0. Enabling a tunnel failed with the message Tunnel Admin Status cannot be set. error: failed to modify. Not able to manage the switch in server A although the fabric is unmonitored in server B. Fabric changes cannot be accepted due to Access Gateway collector run before switch creation. When an Access Gateway-capable device newly joins the fabric, the device type is not updated with an Access Gateway icon in the Connectivity Map and user will not be able to perform the Accept Changes operation. Fabric port report is not showing the details in fabric section in Linux OS. Switch Model Number is always shown as Brocade 200e in Email Call Home Content when switch is in AG Mode, regardless of the switch model. Active zone Configuration is not getting updated when the zone is enabled from CLI for the Fabric OS 6.1.2 seed switch. Event description is not available in Call home centers.

Solution
Workaround prior to upgrade: Reset the levels under the Manage view option in view menu. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close and re-launch the client. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Rediscover the fabric. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Delete the unmonitored fabric and reopen the LSAN Zoning dialog box. Fixed in DCFM 10.4.0.

Edge fabric is not shown in LSAN Zoning dialog box.

40

Closed fixes summary

Solution
Workaround prior to upgrade: Click on any one tunnel [Either Switch-1 side or Switch-2 side]. Proper information will be shown in the Bottom panel. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Un-monitor and monitor the fabrics. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Restart the client to see the changes. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

In the FCIP Tunnel dialog box, newly created tunnel does not show the VE_Port number in the Switch-2 side Tunnels TAB and the Circuit TAB are not displaying the data properly.

IFL is not shown between the fabrics when the user changes the VE-VE connection to VE-VEX between 400 multiprotocol routers.

When different clients are logged in with same username but different case, then creating, editing and copying views in one client do not dynamically update in the other client. Sorting function is not working in Available table in Port Picker dialog box of Realtime Graph, Historical Graph and Report. HAFM references should be removed from the available call home centers. After migrating from CM, Custom community string is copied to AG switch, when the connected McDATA switch was discovered with custom community string. While enabling the tunnel which is persistently disabled, alert has been given to the user but Enable Tunnel button gets disabled and Disable Tunnel button gets enabled. When the tunnel creation fails for the valid reason, if we rollback the changes, roll back was successful, but after some time, tunnel with EMPTY details is displayed in the FCIP Tunnel dialog box. Improve LIC error message when there is no fabric being managed by DCFM, current message causes confusion. Duplicate WWNs are accepted while launching Fabric_Switch_Configuration_Backup dialog box through LIC. Edit tunnel operation failed when trying to edit the tunnel present between 1606 extension SAN switch and multiprotocol extension blade.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Schedule backup based on client time only. Fixed in DCFM 10.4.0.

Configuring Scheduled backup when launched through remote client takes the time of the client instead of the servers time.

In Fabric port report, Incorrect port count shown in Total Fabric Ports. RNID data for direct managed MEOS switches does not appear in the node descriptor list in DCFM. Some Events are not filtered out properly when filtering the master log events through Define Filter dialog box.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

41

Closed fixes summary

Solution
Workaround prior to upgrade: Single click on the Port name column and use Back Space to edit the name. Fixed in DCFM 10.4.0.

Focus is removed from the Port when double clicking the Port Name Column but user could still modify the port name.

Server Tokens has not been set in Apache on the DCFM. Server information could be accessed by third-party tools. Warning message in IP Configuration option in Options dialog box needs to be modified to include the changes to be done in server IP configuration if DNS is not configured. Adding a detached B-Model WWN to the pure Fabric OS fabric is changing the SCC policy to Tolerant mode. Unable to discover the unmonitored logical switches with the same fabric name. Getting an error stating Fabric with same name already exists. In the Add FCIP Circuit dialog box, VLAN ID field is enabled for 1606 Extension SAN switch and multiprotocol extension blade. But VLAN Tagging is not supported in Discovery. Port names with a show as in DCFM when retrieved from the switch. Name does not match what is on the switch. FICON Emulation values are not in sync with CLI; that is, CLI shows the FICON values, but application does not show any value. Error message is given while trying to download firmware when External FTP is configured on the same machine.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Discover it with different fabric name other than default name. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: After the display of blank topology, click the viewall and then click the view created for the fabric. Fixed in DCFM 10.4.0.

After server port mapping, on clicking view created for a host displays the blank topology for the fabric view.

EOSc switches discovered as seed loses manageability and discovery status shows Invalid protocol.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: After Changing the Server IP and restarting the services, the progress bar hangs. Kill the Process and try to launch the Server management Console, the services are started without any issues. Fixed in DCFM 10.4.0.

Progress bar hangs in Server Management Console of Dual NIC PC, when the Server IP is changed in the IP Configuration of the Options dialog box.

User is not able to uncheck the Show Ports option in Right click menu for discovered HBA.

Fixed in DCFM 10.4.0.

42

Closed fixes summary

Solution
Workaround prior to upgrade: Change the seed switch or wait for seed switch auto failover in case of seed switch unreachable, change the credentials in case of authentication failure. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Activation would get successful, if only ports lesser than 256 are selected. Fixed in DCFM 10.4.0.

No proper error message is shown when trying to activate the zone with seed switch in a pure MEOS fabric that is unreachable. User will not know why the zone activation/deactivation failed.

Error message does not give sufficient information for the user when trying to activate zones with port numbers > 255 in IM2.

CPU utilization for the process (dbsrv10.exe) is very high (about 95100%) when there are a number of large fabrics (more than 100 switches). DCFM fails to delete an ACL policy from a CEE capable Switch. Switches discovered through SNMPV1 are getting listed in the Informs table, which is supported only for switches discovered through SNMPV3. In Pure MEOS fabric, the Plus symbol is not removed from the device tree after giving accept changes. DCFM does not show ISLs to connected switches in domainoffset mode 192(0xc0). The structure of the view is not persisted in the device tree and not in sync with the topology, when going to another view and coming back. A few entities are not updated while creating a Standard ACL. HBA in host group and DC SAN Backbone Director in switch group Icons are shown alike in topology and device tree when look and feel is set as Default/Small/Large. Failed to get FCIP circuit configuration: IPC error, please retry the command error has been given in FCIP Tunnel \ Circuit configuration report, while creating a tunnel between DC SAN Backbone Director switches. Swap blade operation fails at the first time, but succeeds in the next attempt. Not Getting VM properties when opening the Properties dialog box from HBA and HBA port. HBA discovered as part of a fabric is shown in the fabric but has no connection to anything in the fabric.

Workaround prior to upgrade: Restart the client. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Launch a new client. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

43

Closed fixes summary

Solution
Workaround prior to upgrade: Check for the dot1x status on the port before assigning it to a LAG. Fixed in DCFM 10.4.0.

DCFM is allowing the user to create an Empty LAG.

No yellow dotted lines are shown when we configure EX-E within the existing E-E connection. VEX option got enabled in the Edit FCIP Tunnel dialog box, after editing the circuit. While editing a policy, if IP address is changed, it is not reflected in the Trigger section in Event Policy main dialog box. In Connection Properties table, E_Port of a 1606 extension SAN switch is shown as gigE port.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Relaunching the client. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close and reopen the Activate Zone Config dialog box to complete the zoning activation. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close and open the FCIP Tunnel dialog box after sometime. We will not see the duplicate tunnels. Fixed in DCFM 10.4.0.

Incorrect number of edits is shown in the error message when Compare Merge dialog box is opened from the Activate Zone Config dialog box.

Duplicate tunnels are shown in the FCIP Tunnel dialog box after creating a new tunnel.

Unknown Badge is shown for all the Discovered B model switches in DCFM professional edition. DCFM Professional 10.3.0 gets unknown error message on launching the Zoning dialog box. Users will be limited to use 300 KB maximum for zone database size. Alert message is not shown at the top of the Zoning dialog box when user has made any zoning configuration through CLI. When Changing the Look and feel option from Default to System, the Connection properties of a Switch or End device is not properly displayed in the Topology.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Manually select the virtual ports and add to the zone. Fixed in DCFM 10.4.0.

When selecting the switch and adding to the zone the HBA virtual ports are not getting added to the zone.

Client crashes on launch when the system is at JRE 1.6.0_14. Internal error is given on modifying the SNMP credentials from Edit Discovery dialog box. Merge wizard says merge operation success, but the master log says merge operation failed.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

44

Closed fixes summary


LS creation, ports added in incorrect order when slot 1, then slot 12 added to Right Hand Side. For VE-VEx connection, in Routing Domain IDs dialog box, unable to move the phantom switch in the edge switch to the selected switches table.

Solution
Fixed in DCFM 10.4.0. Workaround prior to upgrade: Domain ID for the phantom switch can be configured in CLI. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Configure Maximum Historical Event values after migration in SAN-->Options-->Event Storage. Fixed in DCFM 10.4.0.

Maximum Historical Event values are not getting migrated from 10.1.x to 10.3.0 in Event Storage category of Options dialog box,

Discovery status for VF enabled switch is not getting updated in the Discovery dialog box after changing its credentials from v1 to v3. Unable to configure user selected event types for a new user, when logging in as a new user, all events are displayed in selected events column in local/remote client. Yellow banner displayed in ACL tab of Add LAG dialog box is not according to FS. Yellow banner displayed in ACL tab of Edit Port dialog box [LAG member] is not according to Functional Specification document.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Generate Historical Reports for the TE ports at port level and switch level. Fixed in DCFM 10.4.0.

Destination and Destination port columns are blank in Historical Reports for 10 GE Ports.

Accept changes is not working, support save did not complete even after 5 hours, Remote Client is blank.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Reconfigure the scheduling option after migration. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Use CLI or Web Tools to know the TI zone status. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Use the CLI command to export the self signed pub cert: cryptocfg --export -scp -KACcert [scp server address] [scp server login id] [scp server path] Fixed in DCFM 10.4.0.

Scheduled configuration for Technical support save is not migrating from DCFM Professional to Enterprise.

The Active TI zone is not shown as Active in the zone DB tab.

Encryption switch/blade public certs exported during setup are actually CSR and needs to be signed before the switches can connect to the keyvault.

Zone details missing in zone compare.

Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

45

Closed fixes summary


Web Tools session got expired before the session time out value and also OutOfMemoryError Exception given when launched from DCFM. Domain ID offset for the supported M model switch toggles in Device Tree and Topology. The affected port count is shown twice for the switches which were segmented from a fabric and rediscovered separately. Web Tools is not launched for the switches in the SSL enabled server after migration. In the FCIP Tunnel dialog box, for the 1606 extension SAN switch, Router Icon has been shown, but in the topology, it has been shown as Switch Icon. Marching Ants is not shown for GigE ports with one FCIP Tunnel in 1606 extension SAN switches. Web Tools window comes up with invalid session when launched for Logical Switches. Import of firmware to repository fails with two different error messages that are not appropriate. Show port option is grayed out when a right click is made on the storage. When the Client is kept idle for some time, unable to recover connection to server error message is displayed. FICON- port name > 24 gets a inadequate error message make sure name is not null in return. Unable to change the name, but no information as to why.

Solution
Workaround prior to upgrade: Launch WT via IE. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: After re-launching the Compare Merge dialog box, Domain ID and port number is shown in editable zone db. Fixed in DCFM 10.4.0.

In the Compare Merge dialog box, domain ID and port number are not shown in editable db after adding the members to zone / merging the zones from reference zone db when Hex is selected.

Migration is failed while doing remote migration from DCFM 10.3.0 to 10.3.1 after coming back from FTP server page with the selection of PPE in trial edition page.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Manually delete the file under ftproot if firmware import fails. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Open a new client after 5 Minutes. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Unable to import the firmware file if the import fails or that firmware when importing previously.

Mi10k is not getting manageability in topology but Discovery dialog box status shows it is manageable. Connection between an unmanageable McDATA switch and Access Gateway was not displayed after relaunching the client.

46

Closed fixes summary


Zones Not Shown Correctly After Import. From a Management application to Management application migration, the call home that is enabled cannot be disabled.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: No work around for the Create View dialog box. For the Edit View dialog box, after adding the host to the view, if the Edit View dialog box is opened, then the selected fabrics and hosts section shows the host name set in DCFM. Fixed in DCFM 10.4.0.

In the Create View and Edit View dialog boxes, the name field in the Available hosts section and in the selected fabrics and hosts section is not reflecting the Host name set in DCFM and instead showing the same value as the Network address field.

In master log, after highlighting an event from a VF enabled switch, the topology displayed in the topology pane do not always correspond with the source name. Upgrade button should be disabled after the successful upgrade from Professional plus edition to Enterprise Edition. Incorrect value is returned by SMIAgent for the properties Operational Status and Detailed portstate when port state is Online. Wrong property value listed for the properties operational status, EnabledState and Port availability when port state is No Module in Fabric OS Switch. Alert indication BRCD32 was not received when the password gets expired for the discovered switch. Indications are not received for the Virtual Switch Creation and deletion operation performed through DCFM for LifeCycle Indication. Connection Refused Exception received randomly for some of the classes like Brocade_SANProtocolEndpoint, Brocade_NodeFCPort, Brocade_SwitchFCPortStats, Brocade_TopologyView, Brocade_SAN, while executing Enumeration operations to the CIMOM server. CIM_ERR_FAILED exception is given for Enumeration operation of Brocade_InLogicalNetwork in a large fabric configuration. Association operations failed for Brocade_PortController class when FDMI enabled Brocade HBA, discovered through Host Discovery. Association operations failed for Brocade_Platform class when the FDMI enabled Emulex HBA discovered through Fabric Discovery. CIM operations fails for all classes if Fabric Filter is enabled without filtering the fabrics. Fabric Profile: The instances which are retrieved for the class brocade_SANActiveConnection are less compared to the reference operation performed for class Brocade_SanProtocol with the reference class Brocade_SanactiveConnection. Provider fails to return the correct active connection instances for reference operation of brocade_sanprotocolendpoint.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

47

Closed fixes summary


Wrong property value listed for the properties Enabled state, operational status for No Light port state in Fabric OS Switch. Wrong property value listed for the properties operational status when disabling the No Light Port in Fabric OS Switch. Association and Reference operation fails for the class Brocade_switchfcport for the phantom ports. EnumerationInstances and EnumerationInstancesNames counts are mismatching for Brocade_Blade class. Brocade_PCSNEtwokPortSettings Network IDs has no value for the virtual switches. Error message should be displayed at the bottom of Login dialog box if DCFM Server is not running. Unable to change "PoweredOn" property of Brocade_Blade class. Indications are not received for the Switch deletion operation which is performed through CLI. Indications are not received for the Switch Add/Remove operation which is performed through CLI. Incorrect value is displayed for "RequestedStatesSupported" property of Brocade_FCSwitchCapabilities class for M-model switches. Brocade_SwitchFCPort.OperationalStatus is set to 15 (Dormant) for McDATA G ports, but 0 (Unknown) for Brocade G ports. "CIM_ERR_NOT_FOUND" Exception is displayed while doing Get Instance operation on Brocade_SwitchFcPortStats class in VF. Brocade_Chassis.Manufacturer property value is populated as "MCD" for M-model switches.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Add the switch through DCFM client and get the instances. Fixed in DCFM 10.4.0.

Not able to add /delete any fabric through Configuration Tool after discovering a host.

Table persistence fails for the tables present in the Discovery dialog box of Configuration Tool. User is not able to export "Server Certificate" in desired location other than "root" in Solaris Sparc. GetInstances operation failed in Brocade_Node class with Exception CIM_ERR_FAILED for the FDMI enabled HBA discovered through Host Discovery. Help button is not working in the following screens: Server Management Console.CT,Address Properties dialog box.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

48

Closed fixes summary


AssociatorNames fails for Brocade_SanProtocolEndPoint for Phantom switch with CIM classes CIM_Collection,CIM_Product,CIM_ManagedElement. Unable to change "Enabled Default" value of Brocade_SwitchFCPort. Switch Instances were not returned while traversing from other classes to switch in a mixed fabric, but able to get instances while traversing from switch to other classes. Association operations failed from the class Brocade_Node to Brocade_HBAFCPort with Exception CIMM_ERR_FAILED. Brocade_SANProtocolEndPoint instances are not associated to Brocade_LogicalNetwork.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Repeatedly click search button to reach the desired word. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Restart the server. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Application does not highlight all the items which are found, during a search, in the Switch Configuration Repository dialog box.

When DCFM is restored from a previous backup that is SSL enabled to a non-SSL (default) fresh install, user fails to login. Error message does not give sufficient information for the user when trying to activate more than 4096 unique members in IM2 and IM3. Device tree is collapsed automatically when the newly added column is edited in Linux. When Access Gateway is enabled in the switch extra HBA icon is displayed in Topology with AG WWN along with AG that is connected to the Fabric. Application should get updated with the latest information from the switch in a reasonable time when there is any SNMP configuration changes. Logs are shown inconsistently in the Master log when the Filter conditions have been 'Applied or Removed' continuously in the Define Filter dialog box.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Restart the client to see the correct logs. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Open the Port fencing dialog box and once again apply the same policy at the fabric; it will be applied to all the newly added switches. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Start a new client after 30 minutes. Fixed in DCFM 10.4.0.

In Pure MEOS the Threshold (Link) assigned to fabric is not inherited when a new switch joins the fabric,

Trunk E_Port is shown as L port in Topology and shown connected to the Storage device.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

49

Closed fixes summary

Solution
Workaround prior to upgrade: While removing the policy at the All Fabric level if it is also removed from Chassis, the policy is removed from All Fabric and Chassis. Fixed in DCFM 10.4.0.

In MEOS unassigning the threshold from All Fabrics does not unassign the policy assigned to the chassis group and VF

In dual NIC PC the call home service is always showing the source address as Private IP even though the private IP is not selected during installation HBA Icon is not shown in topology when collapsing and expanding the host group after server port mapping. When an M model switch port is disabled, the Calculated Status is not updated from Healthy to Marginal in Port Properties. DCFM is not restricting when domain ID greater than 31 is added to the zone in Interopmode 2, which in turn cause the zone activation failure with inappropriate message.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Do not add members with Domain ID greater than 31 in Interopmode 2. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Close and open the FCIP Tunnel dialog box and try the same operation. Fixed in DCFM 10.4.0.

Nothing happened when clicking the buttons present in the FCIP Tunnel dialog box. Exception thrown in client log.

Actions panel in Add Event Policy dialog box is unusable if the length of the Name is more than 140 characters in the trigger section when policy is reopened for editing. Blank error message was shown in the Server Management Console when trying to test the valid Radius server user credentials. There is a mismatch in the Tunnel ID shown in the FCIP Tunnel dialog box and the Masterlog for the tunnels created between multiprotocol extension blades and the multiprotocol router blades and 400 multiprotocol switches. Failed to add VIP interface, error: Configuration entry exists on a GigE port error shown while clicking the Current Maximum Bandwidth button present in the Edit Circuit dialog box Yellow dash line is not displayed between 4/256 Director ghost and 400 multiprotocol router. Blank FCIP Tunnels dialog box opened when the switches are in Unmanageable state. Ambiguous Error message is displayed during firmware import to the repository when there is a low disk space. Topology is not shown with -ve symbol for switches and end devices which made offline during migration from DCFM 10.1.x to DCFM 10.3.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

50

Closed fixes summary


Product Menu is empty/lost for mapped port Server and Storage devices. Local client and remote client launch takes 30 to 40 seconds in case if no fabrics are discovered in DCFM. Local Client hangs when the total port count is 10172 ports. Not able to receive email when filter is configured in User Management window. In a single switch fabric, user is not able to uncheck the Show Ports option in Right click menu for the switch. The Operation has Failed error message is given while trying to delete a circuit. Chassis based Call home Events like power supply failure events are generated from Non Default Virtual Switches. Node descriptors are missing for DC SAN Backbone Director and DC04 SAN Director when the F_Port has null node name. When activating a new zone config, DCFM shows the old zone config as active.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Reboot the switch and try to delete the tunnel. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Wait until the Zone collection completes. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Launch Web Tools from the web browser for DC04 SAN Director and then try launching switch view from the fabric tree of DC04 SAN Director. Fixed in DCFM 10.4.0.

No functionalities are able to be performed when Web Tools is launched from the fabric tree of Web Tools for any B model switch.

For the existing tunnel which does not have description, if we edit and add the description, Tunnel goes DOWN and does not come UP. When Host Name is changed from the Property dialog box or Device Tree, it is not getting updated unless Client is relaunched or HBA is rediscovered. NPE is given when the user tries to launch EWS for M model switch from the fabric tree. An Error message is displayed stating CAL/XML request failed (error: % Error: Unsupported PFC policy for PGID 2) while creating a CEE map. Upgraded to 10.3.1 and customer zones that previously contained aliases now have WWNs. Port Names are not being cleared during activation of a Saved Configuration File. Call Home event content list the different contributors when generate call home from default virtual switch which have FID other then 128.

Fixed in DCFM 10.4.0. Workaround prior to upgrade: Relaunch Client; Rediscover HBA. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

51

Closed fixes summary


Zoning activation fails in case the port index greater than 255 is part of the zone Configuration in Interopmode 2. LSAN zone aliases missing. No instances listed while executing the EnumerateInstanceNames, EnumerateInstances operations for the class Brocade_HBAFCPortStatistics. GetInstances operation failed for the class Brocade_HBASCSIProtocolEndPoint with Exception CIM_ERR_NOT_FOUND listing wrong instances as an output for EnumerateInstances operation.

Solution
Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0. Fixed in DCFM 10.4.0.

Fixed in DCFM 10.4.0.

DCFM 10.4.1 fixes


Table 5 lists the fixes that were closed for this release. Table 5 DCFM 10.4.1 closed fixes Closed fixes summary
In a cascaded FICON configuration, the user is not allowed to enable FMS mode when 256-area limit is disabled for logical switches. A warning message is displayed and the user is prevented from performing the operation. Properties with wrong values are returned when a switch with firmware version 6.1.x or earlier is managed with invalid SNMP credentials. User may not be able to retrieve the correct Fabric WWN, switch information like vendor, model and serial number. Zoning operation cannot be performed. In an FCR environment with encryption, each container may display duplicate entries for each of the LUNs. When more than one million events are received in a single day, the event purge mechanism may fail and the number of events in the database continues to grow. In this condition, if the user tries to launch the Audit Log dialog, due to a large number of events being retrieved, the server may restart with an out of memory exception.

Solution
Workaround prior to upgrade: Use the CLI to enable the FMS mode. Fixed in DCFM 10.4.1.

Fixed in DCFM 10.4.1.

Fixed in DCFM 10.4.1.

Fixed in DCFM 10.4.1.

52

DCFM 10.4.1a fixes


Table 6 lists the fixes that were closed for this release. Table 6 DCFM 10.4.1a closed fixes Closed fixes summary
SystemName property is displayed without colon for Brocade_EthernetPort and LANEndPoint classes when CEE switch is discovered via ipv6 address. CEE Maps or Ethernet Ports not returned when using Brocade_CEEMapOnEthernetPort. User will not get CEEMapOnEthernetPort if port is enabled after assigning CEEMap.

Solution
Fixed in DCFM 10.4.1a.

Fixed in DCFM 10.4.1a.

DCFM 10.4.2 fixes


Table 7 lists the fixes that were closed for this release. Table 7 DCFM 10.4.2 closed fixes Closed fixes summary
vCenter connectivity view does not update in a timely manner. User will not be able to view the configured LUNs for at least one minute. After changing the name in the Name column for a device that is part of an unmonitored fabric, user cannot change the name back to the original name. In a tape encryption configuration, if the media changer is added as "tape LUN" in a CTC, the status is reported incorrectly. SMI ONLINE DB is always displayed in the DCFM zoning dialog. When configuring multiple LUN settings changing from cleartext to encrypted, first time encryption will be triggered. When first time encryption is in progress, you must wait for it to complete before being able to make any change for the target container as well as the LUNs. Verify IP Connectivity operation fails in DCFM with reason as destination unreachable, but circuit comes up fine when same parameter is configured via CLI. SMI ONLINE DB is created even when SMI agent is not enabled during installation. In encryption configurations, when importing certificates that contain both the text and Base64 encoded portion of the certificate, the import fails, but reports success in DCFM. ISL links are not showing in topology view. Incorrect FC Address is displayed for some ports in the Logical Switches dialog.

Solution
Fixed in DCFM 10.4.2.

Fixed in DCFM 10.4.2.

Fixed in DCFM 10.4.2. Fixed in DCFM 10.4.2.

Fixed in DCFM 10.4.2.

Fixed in DCFM 10.4.2.

Fixed in DCFM 10.4.2.

Fixed in DCFM 10.4.2. Fixed in DCFM 10.4.2. Fixed in DCFM 10.4.2.

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

53

Closed fixes summary


In a pure EOS fabric with Access Gateways, the fabric will not be discovered and no details are given in the error message regarding the failure.

Solution
Fixed in DCFM 10.4.2.

DCFM 10.4.3 fixes


Table 8 lists the fixes that were closed for this release. Table 8 DCFM 10.4.3 closed fixes Closed fixes summary
On the HP StorageWorks Director 2/140 switch, no performance data is collected for ports 128-131. Although performance monitoring is enabled, no data is displayed for the Real Time graph or Marching Ants. The client becomes unresponsive when trying to import an HBA port mapping csv file if any of the devices in the csv file is not currently managed by the application. The client must be terminated from task managerp. When there are multiple AGs connected to different switches in a Fabric sharing the same N-Port numbers, either all devices connected to the different AGs will be displayed in the Product Tree as ports attached to a single switch or all devices will be displayed as a duplicate set of ports. Technical Support data collection fails for switches of a Fabric whose seed switch is running a firmware version lower than v6.2.x or a seed switch that is upgraded to 6.2.x and not rebooted. The user will see an exception in the Master Log indicating a failure in creating folders within the Technical Support directory.

Solution

Fixed in DCFM 10.4.3.

Fixed in DCFM 10.4.3.

Fixed in DCFM 10.4.3.

Fixed in DCFM 10.4.3.

DCFM 10.4.4 fixes


Table 9 lists the fixes that were closed for this release. Table 9 DCFM 10.4.4 closed fixes Closed fixes summary Solution
Workaround prior to upgrade: Users can add the syslog registration via the CLI command. Fixed in DCFM 10.4.4 . Encryption HAC Failover status is not displayed. An error message is displayed when encrypted LUNs are added to the container in DF format. Fixed in DCFM 10.4.4. Fixed in DCFM 10.4.4.

Syslog registration fails for the HP StorageWorks 4/32B SAN Switch with a McData OUI of 08:00:88

54

Closed fixes summary


Port nicknames for end devices having both port and node with the same WWN are not getting imported in Names dialog after migration from EFCM 9.7.4. Application performance will be affected in the scalability environment because the model for the phantom device is incorrectly set in the database after migration.

Solution
Workaround prior to upgrade: Users can manually set the name through the property dialog Fixed in DCFM 10.4.4

Fixed in DCFM 10.4.4.

DCFM 10.4.5 fixes


Table 10 lists the fixes that were closed for this release. Table 10 DCFM 10.4.5 closed fixes Closed fixes summary
When the HP StorageWorks SAN Director 2/128 or the HP StorageWorks 4/256 SAN Director is discovered, the DCFM management service periodically stops and restarts until the server runs out of disk space. Backup with a network drive fails after a server reboot. Problems may occur when customers use DCFM to implement encryption policy changes. When the number of encryption policy changes exceeds 25, DCFM splits the request into two groups which could cause transmission of two encryption requests to the same LUN.

Solution

Fixed in DCFM 10.4.5

Fixed in DCFM 10.4.5

Fixed in DCFM 10.4.5

DCFM 10.4.5a fixes


Table 11 lists the fixes that were closed for this release. Table 11 DCFM 10.4.5a closed fixes Closed fixes summary
In the Encryption Disk LUN View, the twelfth character of the LUN Serial Number (LSN) is getting dropped on some paths; users will experience a mismatch in the LUN state. Supportsave schedule does not function as expected when client and server are in different time zones. The scheduled time setting changes in the scheduler window and supportsave data is not gathered at the expected time. The same re-key session number is displayed for all LUNs in a container in the encryption Rekey Sessions dialog.

Solution
Fixed in DCFM 10.4.5a

Fixed in DCFM 10.4.5a

Fixed in DCFM 10.4.5a

Effective date
June 2011

B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional

55

56

Вам также может понравиться