Operations Guide
1. AD-10 Micro Pulse welding machine introduced a. Features b. For welding c. Electrical parameters
www.aodal.com TEL86-755-27891766 FAX86-755-29647106
d. The overall structure 2. Function and Operation a. Panel display and keypad b. Panel key functions and operations c. Operation order d. Alarm description e. Note 3. Safe use and maintenance
www.aodal.com
TEL86-755-27891766 FAX86-755-29647106
www.aodal.com
TEL86-755-27891766 FAX86-755-29647106
1. Pressure moderate, the pressure would be too bad contact welding materials, resulting in Weld or ignition phenomenon; too much pressure will have a greater welding surface indentation, affect quality of welding. 2. Energy should be adjusted gradually from small to big. 3. The size of the two electrodes, two electrode spacing should be welded with the size, shape consistent and try to flush the two electrodes to ensure a consistent pressure. 4. Welding work piece material and thickness, the quality of the welding significant impact. It should be based on the material and thickness of welding material factors such as choice of different materials and electrode structures, and different welding parameters. 1. Safe use and maintenance 1. Welding machine and reliable grounding. 2. The two electrodes can not short-circuit. 3. Test welding, the energy should be small to large. 4. Plug the power plug should ensure POWER welder in the closed state. 5. Maintain the electrode clean. 6. Term should not disconnect the power. 7. Power can not be put together before the electrode
Fault list
SN 1 2 3 4 5
Failure phenomenon No show boot No current welding
Reason
15A fuse, power-holders Not open the discharge control Over-current fuse
No welding current, showed No contact with the trigger switch, normal Press and ( damage button) alarm lantern flash Power issued a "bang" sound normal
Insurance jump start to open Open power leakage, or switch is too input power small, Note (to 20 amps or more) Opening Remarks: The above listed failures in the control circuit failure are possible, please pay attention to the user.