INSTRUCTION MANUAL PASS BOX CONTROLLER DYNAMIC MODEL NO: SPB105-S VERSION: 1.1
Instrument SI. No :
STANDARD PACK
1) Instruction Manual
-----
1 No 1 No
2) DPB105 Instrument
Checked By : Date :
1. Description:
Pass box is used for material transfer from one Clean room to another clean room. It consists of a rectangular box with two doors. The two doors are interlocked such that two doors cannot be open at the same time, to prevent pressure losses and cross contamination. Our Pass Box controller achieve this by preventing simultaneous access of door by ensuring that when one door for a Pass box is open then other door is closed. before opening of door. 1. When Door 1 is opened the display on the Door 2 will indicate No Go and at the Door 1 the display will indicate Door Open 2. When any of the Door is kept open beyond a particular time say 10 min, a buzzer will be blown and the display at the doors will indicate Close Door 3. When any door is opened the CF lamp is switched on, and the UV lamp will be switched off 4. Both Doors are provided with EM Locks
2. Features:
Advanced Micro controller based. Supports Maximum of 2 doors Supports Electro magnetic locks/Electric strikers Door status indication with high intensity Bar LEDs Status indication: GO, WAIT, DOOR OPEN, CLOSE DOOR Buzzer output for door is kept open more than specified time from 2 to 30 min. UV Lamp controlling o o UV Lamp ON for both Doors closed UV Lamp OFF for both Doors Open
3. Specifications:
GENERAL
Electro Magnetic Lock Source : 24V DC/ 250 mA
ENCLOSURE: Pass Box Controller Enclosure type Mounting : : Power coating Box Wall Display Module Enclosure type Mounting POWER SUPPLY: Power Wattage ENVIRONMENTAL: Operating Temperature : 0 to 500C. : : 80 - 280V, AC 50 Hz 50W : : SS-316L Panel
4. Electromagnetic locks:
A magnetic lock is a simple locking device that consists of an electromagnet and armature plate. By attaching the electromagnet to the door frame and the armature plate to the door, a current passing through the electromagnet attracts the armature plate holding the door shut The magnetic lock relies upon some of the basic concepts of electromagnetism. Essentially it consists of an electromagnet attracting a conductor with a force sufficiently large enough to prevent the door from being opened.
6. OPERATING MODES:
MODE1: Normally Closed ( Default mode) MODE2: Normally Open MODE1: *Locking device is Electro magnetic lock or Electric striker. Normally Close: In this mode, initially both doors in locked condition. Door access by using push button. Status LEDs provided on the Display module indicates whether person can access the door or not. GO = GO LED glow indicates that person can access the door. WAIT = WAIT LED glow indicates that person cannot access the door. CLOSE DOOR = CLOSE DOOR LED indicates that the door is opened more than specified time (default time 2 min). When the door operated from open to closed condition, both doors locked for 4 sec, with in this time person cannot access both doors. Door Buzzer time select from 2 - 30 min. Using jumpers (Refer Section 7.4) Auto close time delay i.e. the time between the door release and energizing is 4 Sec MODE2: *Locking device is Electro magnetic lock or Electric striker. Normally Open: In this mode, initially both doors in un locked condition; here push buttons are used only for indication purpose (no need to press the button). Status LEDs provided on the push button station indicates whether person can access the door or not. GO = GO LED glow indicates that person can access the door. WAIT = WAIT LED glow indicates that person cannot access the door. CLOSE DOOR = CLOSE DOOR LED indicates that the door is opened more than specified time (default time 2 min). When the door operated from open to closed condition, both doors locked for 4 sec, with in this time person cannot access both doors. Door Buzzer time select from 2 - 30 min. Using jumpers (Refer Section 7.4) Auto close time delay i.e. the time between the door release and energizing is 4 Sec
7. Wiring diagram:
C
L
UV
UV LAMP
CF
CF LAMP
1. Connect Door1 Display Module with Door1 Display Module Cable 2. Connect Door2 Display Module with Door2 Display Module Cable
8. MECHANICAL DRAWINGS
Fig (8.1) Figure for Installation of SPB105C-S Controller:
STYRAX INSTRU
MENTS INDIA PV
T LTD
CONTROLLER
230 mm
Pass Box
287 mm
45 mm
OPEN
SPB105
185 mm
9. Ordering Information:
I). Pass Box Controller X Pass Box Type S- Static D- Dynamic includes, a. Controller: X Pass Box Type S- Static D- Dynamic
Model No SPB105
Model No SPB105C
Variants:
SPB105D SPB105D
X X
NOTE: