Вы находитесь на странице: 1из 28

Acvatix the comprehensive range for greater energy efciency

Reliable and economical valves and actuators for any type of application

Answers for infrastructure.

Acvatix the crucial components for every economical and efcient HVAC plant
With Acvatix you decide for a comprehensive range of valves and actuators that stand for maximum control accuracy, energy efciency and availability of HVAC and chiller systems. Whether you select valves with electrohydraulic actuators, with magnetic actuators or combi valves, Acvatix signicantly reduces energy consumption and thus operating costs. The extensive product range offers you valves and actuators with a long service life that meet any control or hydraulic requirements when it comes to the generation, distribution and usage of heating or cooling energy. They are also ideally suited for district heating/cooling, steam or drinking water applications as well as modernizations or renovations. For you, this means that you are ideally prepared for any type of application with very small to very high volumetric ows or differential pressures whether for single-family houses or apartment blocks, modern ofce buildings, public buildings, distributed properties or HVAC and special plants in industrial environments.

Rugged valves and actuators long lasting, convenient and accurate


A safe investment thanks to high quality Acvatix valves and actuators stand out due to their high quality and very long service life. Their high reliability and fail safety ensure consistent plant availability. They are based on Siemens many years of experience. In addition, decades of backward compatibility of the products provides constant investment protection: Valves or actuators can be easily exchanged. Intelligent comfort for optimum control Acvatix actuators are suited for all types of controllers used in connection with intelligent and optimum room and building automation. Auxiliary functions support efcient plant monitoring and rapid troubleshooting. In the event of failure of individual plant components, energy supply, distribution or consumption can still be ensured via convenient manual operation. When used in ventilation systems, for instance, the valves tted with magnetic actuators form the basis for specically balanced comfort in rooms or zones thanks to their high control accuracy and speed. Full support in every respect Whether for planning, commissioning or service, Siemens offers you a variety of tools to easily select and size valves and actuators. These tools include special software and valve slide rules as well as online resources and practice-oriented training. In addition, Siemens global sales and service network ensures rapid, straightforward delivery and supports you with all questions relating to planning, engineering or the products. Best quality based on many years of experience Acvatix is based on over 60 years of experience in valve and actuator construction with continual incremental development and state-of-the-art technologies. Valves and actuators come from Siemens own development and production facilities. They are optimized based on the many years of eld experience and tested intensively in Siemens own labs. The result: For decades, Acvatix products have been used successfully millions of times in simple and complex HVAC plants throughout the world. Therefore, you will receive the best quality and greatest reliability.

Highlights
Unique variety for optimum planning and design of the entire hydraulic circuit for all types of application (heating, cooling, drinking water and steam) High energy efciency thanks to a comprehensive range, high control accuracy and speed Safe investments due to high reliability, long service life and backward compatibility even under demanding conditions Intelligent comfort thanks to compatibility with all room and building automation controllers Full support during planning, engineering and service High, tested quality and long service life based on many years of experience plus own development and production

Contents
Flanged 2-port and 3-port valves Threaded 2-port and 3-port valves Threaded 2-port and 3-port ball and slipper valves Buttery valves Elite / Standard line Combi valves TRV line On /Off line Refrigerant valves Industrial HVAC plants and special applications Sizing and selection of actuators 6 8 10 11 14 15 16 17 18 20 22
3

Acvatix for central HVAC plants


The heart: the central HVAC plant Whether they operate with water, steam or heat transfer oils, central HVAC plants are used to generate and distribute heating and cooling energy to maintain comfortable temperatures in buildings, zones and rooms. They consist of primary plants for heating, cooling, ventilation and air conditioning as well as of distribution networks in buildings and district heating/cooling systems. Acvatix valves and actuators ensure energy-efcient operation for optimum comfort in all operating and load situations. Your variety for energy generation and distribution Acvatix offers you all types of valves and actuators required for central HVAC plants. The range includes 2-port and 3-port valves with anged or threaded connections and buttery valves combined with actuators that can be driven by all room and building automation controllers. The valves are suited for open and closed circuits with water, water with anti-freeze, drinking water, steam and other media. This means that with Acvatix, you can implement all control, shutoff and changeover functions in HVAC and drinking water plants, whether simple, small, large or complex. Everything for high energy efciency Acvatix helps to ensure that buildings achieve the highest energy efciency classes according to the European Norm EN 15232 (energy performance of buildings). This means you can design your plant optimally in terms of hydraulics and control thanks to the nely graduated range also for part load behavior such as summer/winter or day/night operation. This reduces energy consumption and thus operating costs. In addition, actuators with very short positioning times optimize the energy efciency in fast controlled systems, in controlled systems with a high degree of difculty, or in plants with very dynamic plate heat exchangers. The electrohydraulic actuators control very high dif ferential pressures and large volumetric ows using little energy. And the highprecision, fast-acting valves with magnetic actuator save energy particularly in chilled water plants.

Generation Distribution

Consumption/Use

Investments that pay off in the long term Due to their rugged design and manufacture according to international production and testing standards, Acvatix valves and actuators have a particularly long service life. Thanks to their backward compatibility, they can be simply replaced with new products even after decades of operation. And that pays off also: Various auxiliary functions are available to increase the protection of plants and buildings, such as an integrated fail safe function in the event of a power failure, or position feedback and connection options for frost protection devices, for example.

Designed for installers and users With Acvatix you benet from ease of service and installation. You can simply and cost-efciently install and commission the actuators. The freedom from maintenance minimizes effort and operating costs. And manual operation with no need for additional tools assists you not only during commissioning, but also in unforeseen operating situations. Designed for the environment The Acvatix range also meets the most demanding requirements with respect to the environment, which the ISO 14000 certication veries. The environmental friendliness of Acvatix ranges from environmentally sound development and production in accordance with the Siemens standard SN 36350 and current environmental standards, such as RoHS and WEEE, to the possibility of environmentally compatible disposal.

Highlights
All types of valves and actuators required for the generation and distribution of heating and cooling energy High energy and cost efciency thanks to optimal sizing and selection and energy-saving components, such as fast-acting and highly accurate actuators Long-term investment protection thanks to long service life, backward compatibility and protection functions Auxiliary and in-built functions for convenient operation and enhanced room comfort Easy to service and install, including ergonomic operation with no tools and clear position indication, and a high degree of environmental compatibility

Convenient functions for any situation Based on the integrated position feedback of the actuators, plants can be monitored efciently and faults rectied quickly. If individual plant components fail, the supply of heating or cooling energy can still be ensured thanks to convenient manual operation.

Flanged 2-port and 3-port valves with 20/40 mm actuators


Typical applications Heating plants Ventilation and air conditioning plants Heat and cooling generation Heat and cooling distribution Actuators SQX.. SKD.. SKB.. SKC.. Operating voltage AC 230 V Data sheet N4554 N4561 N4564 N4566 Positioning signal Positioning time [s] SQX SKD SKB/SKC 3-position 150 120 120 3-position 120 120 3-position 35 3-position 30 3-position 150 120 120 3-position 120 120 3-position 35 0...10 V, 4...20 mA 35 30 120 0...10 V, 4...20 mA 30 120 N4410 VXF21.22..25 1) VXF21.25-.. 2) VXF21.39..40 1) VXF21.40-.. VXF21.50 VXF21.50-40 VXF21.65 VXF21.65-63 VXF21.80 VXF21.80-100 VXF21.90 VXF21.100-160 N4420 VXF31.15-.. 2) VXF31.24..25 1) VXF31.25-.. VXF31.39..40 1) VXF31.40-.. VXF31.50 VXF31.50-40 VXF31.65 VXF31.65-63 VXF31.80 VXF31.80-100 VXF31.90 VXF31.100-160 VXF31.91 VXF31.125-250 VXF31.92 VXF31.150-315 N4430 VXF40.15-.. 2) VXF40.25-.. VXF40.40-.. VXF40.50-.. VXF40.65-.. VXF40.80-.. VXF40.100-.. VXF40.125-.. VXF40.150-.. N4440 VXF41.14..15 VXF41.24..25 VXF41.39..40 VXF41.49..50 VVF41.65 VXF41.65 VVF41.80 VVF41.90 VVF41.91 VVF41.92 -10...150 C (180 C) N4345 VVF45.49..50 VVF45.65 VVF45.80 VVF45.90 VVF45.91 VVF45.92 VXF41.80 VXF41.90 VXF41.91 VXF41.92 DN 25 25 40 40 50 50 65 65 80 80 100 100 DN 15 25 25 40 40 50 50 65 65 80 80 100 100 125 125 150 150 DN 15 25 40 50 65 80 100 125 150 DN 15 25 40 50 65 80 100 125 150 DN 50 65 80 100 125 150 700 N Spring return function 20 mm 1000 N 2800 N 40 mm 2800 N

AC 24 V

SQX32.00 SQX32.03 SQX82.00 SQX82.03 SQX62 ps [kPa] 600 600 500 500 300 300 175 175 100 100 ps [kPa] 1000 1000 1000 525 525 325 325 175 175 100 100 ps [kPa] 1600 1550 525 325 175 100 ps [kPa] 350 pmax [kPa] 300 300 300 300 300 300 175 175 100 100 pmax [kPa] 300 300 300 300 300 300 300 175 175 100 100 pmax [kPa] 300 300 300 300 175 100 pmax [kPa] 800 800 500 300 350

SKD32.50 SKD32.51 SKD32.21 SKD82.50 SKD82.51 SKD60 SKD62 ps [kPa] 600 600 600 600 450 450 275 275 175 175 ps [kPa] 1000 1000 1000 775 775 475 475 275 275 175 175 ps [kPa] 1600 1600 775 475 275 175 ps [kPa] 500 pmax [kPa] 300 300 300 300 300 300 275 275 175 175 pmax [kPa] 300 300 300 300 300 300 300 275 275 175 175 pmax [kPa] 300 300 300 300 275 175 pmax [kPa] 800 800 750 400 500

SKB32.50 SKB32.51 SKB82.50 SKB82.51 SKB60 SKB62 ps [kPa] 600 600 600 600 600 600 600 600 500 500 ps [kPa] 1000 1000 1000 1000 1000 1000 1000 750 750 500 500 ps [kPa] 1600 1600 1600 1300 750 500 ps [kPa] 1400 pmax [kPa] 300 300 300 300 300 300 300 300 300 300 pmax [kPa] 300 300 300 300 300 300 300 300 300 300 300 pmax [kPa] 300 300 300 300 300 300 pmax [kPa] 800 800 800 1000 800

SKC32.60 SKC32.61 SKC82.60 SKC82.61 SKC60 SKC62 ps [kPa] 300 300 ps [kPa] 300 300 200 200 125 125 ps [kPa] 300 200 125 ps [kPa] pmax [kPa] 200 200 pmax [kPa] 200 200 150 150 100 100 pmax [kPa] 200 150 100 pmax [kPa]

PN 6 Data sheet

PN 10 Data sheet

PN 16 Data sheet

PN 16 Data sheet

-10150 C N4310 VVF21.22..25 1) VVF21.25-.. 2) VVF21.39..40 1) VVF21.40-.. VVF21.50 VVF21.50-40 VVF21.65 VVF21.65-63 VVF21.80 VVF21.80-100 VVF21.90 VVF21.100-160 -10150 C N4320 VVF31.15-.. 2) VVF31.24..25 1) VVF31.25-.. VVF31.39..40 1) VVF31.40-.. VVF31.50 VVF31.50-40 VVF31.65 VVF31.65-63 VVF31.80 VVF31.80-100 VVF31.90 VVF31.100-160 VVF31.91 VVF31.125-250 VVF31.92 VVF31.150-315 -10...150 C N4330 VVF40.15-.. 2) VVF40.25-.. VVF40.40-.. VVF40.50-.. VVF40.65-.. VVF40.80-.. VVF40.100-.. VVF40.125-.. VVF40.150-.. -10...150 C (180 C) N4340 VVF41.49..50

kvs [m/h] 1.9 / 3 / 5 / 7.5 2.5 / 4 / 6.3 / 10 12 / 19 16 / 25 31 40 49 63 78 100 124 160 kvs [m/h] 2.5 / 4 5 / 7.5 6.3 / 10 12 / 19 16 / 25 31 40 49 63 78 100 124 160 200 250 300 315 kvs [m/h] 1.9 / 2.5 / 3 / 4 5 / 6.3 / 7.5 / 10 12 / 16 / 19 / 25 31 / 40 49 / 63 78 / 100 124 / 160 200 / 250 300 / 315 kvs [m/h] 1.9 / 3 5 / 7.5 12 / 19 19 / 31 49 78 124 200 300 kvs [m/h] 19 / 31 49 78 124 200 300

PN 16 Data sheet

800 600 500 500 400 350 300 250 200 175 125 100 ps pmax ps pmax ps pmax ps pmax [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] 1600 1200 1600 1000 1600 700 1600 450 1600 300 1600 200

Flanged 2-port and 3-port valves with 20/40 mm actuators


Typical applications Heating plants Ventilation and air conditioning plants Heat and cooling generation Heat and cooling distribution Actuators SQX.. SKD.. SKB.. SKC.. Operating voltage AC 230 V Data sheet N4554 N4561 N4564 N4566 Positioning time [s] SQX SKD SKB/SKC 3-position 150 120 120 3-position 120 120 3-position 35 3-position 30 3-position 150 120 120 3-position 120 120 3-position 35 0...10 V, 4...20 mA 35 30 120 0...10 V, 4...20 mA 30 120 Positioning signal DN 15 15 15 15 15 25 40 N4482 VXF61.14..15 1) VVF61.23..25 1) VXF61.24..25 1) VVF61.39..40 1) VXF61.39..40 1) VVF61.49..50 1) VXF61.49..50 1) VVF61.65 VXF61.65 VVF61.80 VXF61.80 VVF61.90 VXF61.90 VVF61.91 VXF61.91 VVF61.92 DN 15 15 15 25 40 50 65 80 100 125 kvs [m/h] 0.16 / 0.2 / 0.25 0.32 / 0.4 / 0.5 0.63 / 0.8 / 1 1.25 / 1.6 / 2 2.5 / 3.2 / 4 5 / 6.3 / 8 / 10 12.5 / 16 / 20 / 25 kvs [m/h] 0.19 / 0.3 / 0.45 0.7 / 1.2 1.9 / 3 3 / 5 / 7.5 5 / 7.5 12 / 19 19 / 31 49 78 124 200 700 N Spring return function 20 mm 1000 N 2800 N 40 mm 2800 N

AC 24 V

SQX32.00 SQX32.03 SQX82.00 SQX82.03 SQX62

SKD32.50 SKD32.51 SKD32.21 SKD82.50 SKD82.51 SKD60 SKD62

SKB32.50 SKB32.51 SKB82.50 SKB82.51 SKB60 SKB62

SKC32.60 SKC32.61 SKC82.60 SKC82.61 SKC60 SKC62

PN 25 Data sheet

PN 40 Data sheet

-20...150 C (180 C) N4373 VVF52.15-.. 2) VVF52.15-.. VVF52.15-.. VVF52.15-.. VVF52.15-.. VVF52.25-.. VVF52.40-.. -25...220 C (350 C) N4382 VVF61.09..11 1) VVF61.12..13 1) VVF61.14..15 1)

ps pmax ps pmax ps pmax ps pmax [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] [kPa] 2500 2500 2500 2500 2500 1500 500 ps [kPa] 1600 1600 1600 1600 1600 1200 400 pmax [kPa] 2500 2500 2500 2500 2500 2250 750 ps [kPa] 4000 4000 4000 2250 1600 1600 1600 1600 1600 1600 700 pmax [kPa] 1600 1600 1600 1200 1600 1200 2500 2500 2500 2500 2500 2500 2000 ps [kPa] 4000 4000 4000 4000 4000 4000 1600 1600 1600 1600 1600 1600 1600 pmax ps pmax [kPa] [kPa] [kPa] 1600 1600 1600 1600 1600 1600 1600 1200 1600 1000 4000 1000 800 4000 700 500 4000 450 300 4000 300 200 4000 200 125

150 300 VXF61.92 09...15, 14...15, 23...25, 24...25, 39...40, 49...50 = insert number in place of kvs value 2) .. = insert kvs value
1)

Flanged 2-port and 3-port valves tted with magnetic actuator


Valve type MXF461.. M3P..FY.. MVF461H.. P = media containing mineral oil, M = silicon-free version PN 16 Data sheet 1...130 C N4455 MXF461.15-.. MXF461.20-5.0 MXF461.25-8.0 MXF461.32-12 MXF461.40-20 MXF461.50-30 MXF461.65-50 1...120 C N4454 M3P80FY M3P100FY 1...180 C N4361 MVF461H15-.. MVF461H20-5 MVF461H25-8 MVF461H32-12 MVF461H40-20 MVF461H50-30 DN 15 20 25 32 40 50 65 80 100 DN 15 20 25 32 40 50 kvs [m/h] 0.6 / 1.5 / 3.0 5 8 12 20 30 50 80 130 kvs [m/h] 0.6 / 1.5 / 3.0 5 8 12 20 30 Typical applications Supply air control with/without cascade Fast-acting heat exchanger control High-precision process control Operating voltage AC 24 V AC 24 V AC/DC 24 V Positioning signal 0...10 V, 2...10 V, 4...20 mA 0...10 V, 4...20 mA 0...10 V, 2...10 V, 0...20 mA, 4...20 mA Type sufx P, M P

ps pmax [kPa] [kPa] Note 300 300 To be used as 2-port or mixing valves, not as diverting valves. 300 300 Selectable valve characteristic: equal-percentage or linear. 300 300 300 300 300 300 300 300 300 300 300 300 200 200 ps pmax [kPa] [kPa] 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

PN 16 Data sheet

Threaded 2-port and 3-port valves with 5.5 mm actuators


Typical applications Heating plants District heating Ventilation and air conditioning plants Actuators SQS.. Data sheet N4573 Positioning signal 3-position 3-position 3-position 3-position 010 V 210 V Spring return function G [inch] G 1B G 1B G 1B G 1B G 1B G 2B G 2B G [inch] G B G B G 1B G 1B kvs [m/h] 0.25 / 0.4 / 0.63 1 / 1.6 2.5 / 4 6.3 10 16 25 kvs [m/h] 0.25 / 0.4 / 0.63 1 / 1.6 / 2.5 4 6.3 SQS35.50 SQS35.53 SQS65.5 ps [kPa] 1600 725 400 750 400 250 125 ps [kPa] 2500 2000 1000 800 SQS35.00 SQS35.03 SQS85.00 SQS85.03 SQS65 SQS65.2 pmax [kPa] 400 400 400 400 400 250 125 pmax [kPa] 1200 1200 1000 800 5.5 mm 400 N 400 N

Operating voltage AC 230 V AC 24 V

Positioning time [s] 150 35 35 DN 15 15 15 20 25 32 40 DN 15 15 20 25 150 35 150 35 35 35

PN 16 Data sheet

PN 25 Data sheet

1120 C N4364 VVG44.15-.. VVG44.15-.. VVG44.15-.. VVG44.20-6.3 VVG44.25-10 VVG44.32-16 VVG44.40-25 1130 C N4379 VVG55.15-.. VVG55.15-.. VVG55.20-4 VVG55.25-6.3

N4464 VXG44.15-.. VXG44.15-.. VXG44.15-.. VXG44.20-6.3 VXG44.25-10 VXG44.32-16 VXG44.40-25

.. = kvs value

Threaded 2-port and 3-port valves with 5.5 mm actuators


Typical applications Heating plants Ventilation plants Actuators SSC.. Operating voltage AC 230 V AC 24 V AC/DC 24 V PN 16 Data sheet 1110 C N4845 VVP45.20-4 VVP45.25-6.3 VVP45.25-10 VVP45.32-16 VVP45.40-25 Data sheet N4895 Positioning signal 3-position 3-position 010 V Positioning time [s] 150 150 30 DN 20 25 25 32 40 30 Spring return function kvs [m/h] 4 6.3 10 16 25 5.5 mm 300 N

SSC31 SSC81 SSC61 ps [kPa] 350 300 300 175 75

SSC61.5 pmax [kPa] 350 300 300 175 75

N4845 VXP45.20-4 VXP45.25-6.3 VXP45.25-10 VXP45.32-16 VXP45.40-25

G [inch] G 1B G 1B G 1B G 2B G 2B

Combi valves with actuators


Typical applications Air handling units Actuators SQD.. SSD.. AC 230 V AC 24 V Data sheet N4540 N4861 Positioning time [s] 150 150 75 75 75 170 43 43 SSD31 SSD81 SSD61 SSD61EP 1) SSD61.2 SQD35.00 SQD85.03 SQD65 pmin [kPa] 26 26 32 32 pmax [kPa] 400 3) 400 3) 400 3) 400 3) 5.5 mm 250 N 6.5 mm 400 N

Operating voltage Positioning signal 3-position 3-position 010 V AC/DC 24 V 010 V 010 V 210 V 1) Selectable: linear or equal-percentage valve characteristic PN 25 Data sheet

1120 C pmin pmax Rp V Vmin DN [kPa] [kPa] [inch] [l/h] [l/h] N4853 VPI45.25F1.5 25 Rp 1 280 1720 16 400 VPI45.25F1.5Q 2) 25 Rp 1 280 1720 16 400 VPI45.25F2 25 Rp 1 350 2040 22 400 VPI45.25F2Q 2) 25 Rp 1 350 2040 22 400 VPI45.32F3 32 Rp 1 560 3050 18 400 VPI45.32F3Q 2) 32 Rp 1 560 3050 18 400 VPI45.40F7 40 Rp 1 2355 7105 VPI45.40F7Q 40 Rp 1 2355 7105 VPI45.50F8.5 50 Rp 2 2664 8586 VPI45.50F8.5Q 50 Rp 2 2664 8586 2) Fitted with pressure testing points 3) For pmax = 400 kPa: leakage rate > 0.05% of volumetric ow V100. For pmax = 230 kPa: leakage rate 0...0.05% of volumetric ow V100

Threaded 2-port and 3-port valves with 20 mm actuators


Typical applications Heating plants Ventilation and air conditioning plants Heat generation Heat distribution District heating Actuators SQX.. SKD.. SKB.. SKC.. Operating voltage AC 230 V Data sheet N4554 N4561 N4564 N4566 Positioning signal Positioning time [s] SQX SKD SKB 3-position 150 120 120 3-position 120 120 3-position 35 3-position 30 3-position 150 120 120 3-position 120 120 3-position 35 0...10 V, 4...20 mA 35 30 120 0...10 V, 4...20 mA 30 120 DN VXG41.1301 VXG41.1401 VXG41.1501 VXG41.2001 VXG41.2501 VXG41.3201 VXG41.4001 VXG41.5001 15 15 15 15 20 25 32 40 50 G [inch] G 1B G 1B G 1B G 1B G 1B G 1B G 2B G 2B G 2B 700 N Spring return function 20 mm 1000 N 2800 N

AC 24 V

kvs [m/h] 0.63 / 1 1.6 2.5 4 6.3 10 16 25 40

SQX32.00 SQX32.03 SQX82.00 SQX82.03 SQX62 ps [kPa] 1600 1600 1600 1600 1600 1550 875 525 300 pmax [kPa] 800 800 800 800 800 800 800 525 300

SKD32.50 SKD32.51 SKD32.21 SKD82.50 SKD82.51 SKD60 SKD62 ps [kPa] 1600 1600 1600 1600 1600 1600 1275 775 450 pmax [kPa] 800 800 800 800 800 800 800 775 450

SKB32.50 SKB32.51 SKB82.50 SKB82.51 SKB60 SKB62 ps [kPa] 1600 1600 1600 1600 1600 1600 1600 1600 1225 pmax [kPa] 800 800 800 800 800 800 800 800 800

PN 16 -25150 C Data sheet N4363 VVG41.11..12 VVG41.13 VVG41.14 VVG41.15 VVG41.20 VVG41.25 VVG41.32 VVG41.40 VVG41.50

N4463 VXG41.15 VXG41.20 VXG41.25 VXG41.32 VXG41.40 VXG41.50

Threaded 2-port and 3-port valves tted with magnetic actuator


Typical applications Valve type MXG461.. Supply air control with/without cascade Fast-acting heat exchanger control MXG461B.. Domestic hot water mixing control MXG461S.. High-precision process control MXG462S.. P = media containing mineral oil, M = silicon-free version PN 16 Data sheet 1...130 C N4455 MXG461.15-.. MXG461.20-5.0 MXG461.25-8.0 MXG461.32-12 MXG461.40-20 PN 16 Data sheet MXG461.50-30 -20...130 C N4461 MXG461B15-.. MXG461B20-5 MXG461B25-8 MXG461B32-12 MXG461B40-20 PN 16 Data sheet MXG461B50-30 1130 C N4465 MXG461S15-1.5 MXG461S20-5.0 MXG461S25-8.0 MXG461S32-12 -20...130 C N4466 MXG462S50-30 Operating voltage AC 24 V AC/DC 24 V AC 24 V AC/DC 24 V G [inch] G 1B G 1B G 1B G 2B G 2B G 2B kvs [m/h] 5 8 12 20 30 kvs [m/h] 0.6 / 1.5 / 3 5 8 12 20 30 kvs [m/h] 1.5 5 8 12 30 Positioning signal 0...10 V, 2...10 V, 4...20 mA 0...10 V, 2...10 V, 0...20 mA, 4...20 mA 0...10 V, 2...10 V, 4...20 mA 0...10 V, 2...10 V, 0...20 mA, 4...20 mA ps [kPa] 300 300 300 300 300 ps [kPa] 1000 800 700 600 600 600 ps [kPa] 300 300 300 300 600 pmax [kPa] Note 300 300 300 300 300 300 pmax [kPa] Note 1000 To be used as 2-port or mixing 800 valves, not as diverting valves. Selectable valve characteristic: 700 equal-percentage or linear. 600 600 600 pmax [kPa] Note 300 300 300 300 600
DVGW-certied

Type sufx P, M

DN 15 20 25 32 40 50

0.6 / 1.5 / 3.0 300

To be used as 2-port or mixing valves, not as diverting valves. Selectable valve characteristic: equal-percentage or linear.

G DN [inch] 15 20 25 32 40 50 DN 15 20 25 32 50 G 1B G 1B G 1B G 2B G 2B G 2B G [inch] G 1B G 1B G 1B G 2B G 2B

To be used as 2-port or mixing valves, not as diverting valves. Selectable valve characteristic: equal-percentage or linear. Parts that are in contact with medium in stainless steel.

DVGW = German Technical and Scientic Association for Gas and Water

Union nuts for threaded valves


Union nuts for threaded valves See page 21

2-port and 3-port ball valves with rotary actuators


Typical applications Heating plants Ventilation and air conditioning plants Heat and cooling generation Heat and cooling distribution Actuators GQD..9A GDB..9E GMA..9E GLB..9E Operating voltage AC 230 V AC 24 V AC/DC 24 V PN 40 Data sheet Data sheet N4659 N4657 N4658 N4657 Positioning signal 3-position 3-position 0...10 V 3-position 0...10 V Positioning time [s] GQD GDB GMA 150 150 150 30 / 15 90 / 15 30 / 15 90 / 15 GLB 150 150 150 2 Nm Spring return function 5 Nm 7 Nm 10 Nm

GDB331.9E GDB131.9E GDB161.9E GQD131.9A GMA131.9E GQD161.9A GMA161.9E ps pmax [kPa] [kPa] 1400 350 1400 350 1400 350 1400 350 ps pmax [kPa] [kPa] 1400 350 1400 350 1400 350 1400 350 1400 350 1400 350 ps [kPa] 1400 1400 1400 1400 1400 1400 1000 1000 800 800 800 600 600 600

GLB331.9E GLB131.9E GLB161.9E pmax [kPa] 350 350 350 350 350 350 350 240 350 240 240 350 240 240

1120 C Rp kvs DN [inch] [m/h] N4211 N4211 VAI61.15-.. VBI61.15-.. 15 Rp 1.6 / 2.5 / 4 / 6.3 VAI61.15-.. 15 Rp 1 / 10 VAI61.20-.. VBI61.20-.. 20 Rp 4 / 6.3 VAI61.20-.. 20 Rp 10 10 VAI61.25-.. VBI61.25-.. 25 Rp 1 6.3 / 16 VAI61.25-.. 25 Rp 1 VAI61.32-.. VBI61.32-.. 32 Rp 1 16 VAI61.32-.. 32 Rp 1 10 / 25 VAI61.40-.. 40 Rp 1 16 VAI61.40-.. VBI61.40-.. 40 Rp 1 25 VAI61.40-.. 40 Rp 1 40 VAI61.50-.. 50 Rp 2 25 VAI61.50-.. VBI61.50-.. 50 Rp 2 40 VAI61.50-.. 50 Rp 2 63 VBI61..: For noiseless operation, the pmax value of 200 kPa should not be exceeded

3-port and 4-port slipper valves with rotary actuators


Typical applications Small to medium-size heating plants Actuators SQK34../84.. SQK33.. SQL33../83.. Operating voltage AC 230 V AC 24 V Mounting set PN 6 Data sheet 1...120 C N4241 VBF21.40 VBF21.50 VBF21.65 VBF21.80 VBF21.100 VBF21.125 VBF21.150 1...120 C N4233 VBG31.20 VBG31.25 VBG31.32 VBG31.40 1...120 C N4232 VBI31.20 VBI31.25 VBI31.32 VBI31.40 1...120 C N4252 VCI31.20 VCI31.25 VCI31.32 VCI31.40 Data sheet N4508 N4506 N4506 Positioning Positioning time [s] signal SQK SQK33 3-position 135 125 3-position 3-position 135 SQL 125 30 125 kvs [m/h] 25 40 63 100 160 550 820 kvs [m/h] 6.3 10 16 25 kvs [m/h] 6.3 10 16 25 kvs [m/h] 6.3 10 16 25 5 Nm 5 Nm 10 Nm / 12.5 Nm

SQK34.00 SQK84.00 pmax [kPa] 30 30 pmax [kPa] 30 30 30 30 pmax [kPa] 30 30 30 30 pmax [kPa] 30 30 30 30

SQK33.00 ASK32 pmax [kPa] 30 30 pmax [kPa] 30 30 30 30 pmax [kPa] 30 30 30 30 pmax [kPa] 30 30 30 30

SQL33.00 SQL33.03 SQL83.00 ASK31 ASK32 pmax [kPa] 30 30 30 30 30 pmax [kPa] pmax [kPa] pmax [kPa] pmax [kPa] 30 30 pmax [kPa] 30 30 30 30 pmax [kPa] 30 30 30 30 pmax [kPa] 30 30 30 30

DN 40 50 65 80 100 125 150 DN 20 25 32 40 DN 20 25 32 40 DN 20 25 32 40 G [inch] G 1B G 1B G 2B G 2B Rp [inch] Rp Rp 1 Rp 1 Rp 1 Rp [inch] Rp Rp 1 Rp 1 Rp 1

PN 10 Data sheet

PN 10 Data sheet

PN 10 Data sheet

Mounting sets ASK40, ASK41 for products of other manufacturers: mounting sets for SQK33../SQL33../SQL83.. for 3-port and 4-port slipper valves from AXA, BUDERUS, CENTRA, ESBE/SHUNT AB, LOELL, MUEHLENBERG, ONDAMIX and VIESSMANN. For additional details, see data sheet N4291.

10

Buttery valves with rotary actuators


Typical applications Shutoff or control For closed or open circuits Actuators Data sheet 12.5 Nm 20 Nm 40 Nm 100 Nm 400 Nm 1200 Nm

SQL33../83.. N4506 SQL35../85.. N4505 SQL36.. N4505 Operating voltage AC 230 V Positioning signal 3-position 3-position 3-position 3-position 3-position 3-position 3-position

Positioning time [s] SQL36E65 6 1) SQL36E110 12 1) SQL36E160 24 1) SQL36E50F04 SQL36E50F05 25 SQL33.03 2) 30 SQL33.00 SQL35.00 125 SQL83.00 SQL85.00 AC 24 V 125 ASK35 ASK33 Mounting set .1 .2 1) With auxiliary module SEZ31.1 variable positioning time: SQL36E65: 30180 s, SQL35E110: 60360 s, SQL36E160: 120720 s 2) Torque 10 Nm -10...120 C N4131 VKF41.40 VKF41.50 VKF41.65 VKF41.80 VKF41.100 VKF41.125 VKF41.150 VKF41.200 PN 16 -10...120 C Data sheet N4136 VKF46.40 VKF46.50 VKF46.65 VKF46.80 VKF46.100 VKF46.125 VKF46.150 VKF46.200 VKF46.250 VKF46.300 VKF46.350 VKF46.400 VKF46.450 VKF46.500 VKF46.600 PN 16 -10...120 C Data sheet N4136 VKF46.350TS VKF46.400TS VKF46.450TS VKF46.500TS VKF46.600TS 3) With ASK35 mounting kit PN 16 Data sheet DN 40 50 65 80 100 125 150 200 DN 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 DN 350 400 450 500 600 kvs [m/h] 50 80 200 400 760 1000 2100 4000 kvs [m/h] 50 85 215 420 800 1010 2100 4000 6400 8500 11500 14500 20500 21000 29300 kvs [m/h] 11500 14500 20500 21000 29300 ps [kPa] 500 500 500 500 500 300 250 125 ps [kPa] ps [kPa] ps [kPa] 500 3) 300 3) ps ps [kPa] [kPa] 1600 1600 1600 ps [kPa] 1600 1600 1000 ps [kPa] ps [kPa] ps [kPa] 1600 1600 1600 ps [kPa] ps [kPa] ps [kPa] 1600 1600 1000 ps [kPa] ps [kPa] ps [kPa] 1600 1000 ps [kPa] ps [kPa] ps [kPa] 1000 1000 600 300 ps [kPa] ps [kPa] ps [kPa] 300 300 300 ps [kPa] 1000 1000 1000 1000 1000

Recommended maximum ow velocity: VKF41.. 4 m/s for water, 40 m/s for gas VKF46.. 4.5 m/s for water, 60 m/s for gas

11

Acvatix for room and zone applications


On-site control: room and zone applications The room and zone controllers ensure comfort in individual living and working spaces in all operating situations. Quiet, fast-acting and accurate valves and actuators are necessary to minimize temperature uctuations and to save energy. A wide selection for various combinations The Acvatix range can be combined in a number of ways, making a signicant contribution to optimum room and zone control. The products range from the high-performance models of the Elite line to radiator valves. They can be combined with thermostatic, thermal or electromotoric actuators. The recommended device combinations for the corresponding applications were all tested in the lab and in the eld for their suitability and control performance. Just save energy room by room, zone by zone With the extensive product range, you can optimally design room and zone applications with hydraulics and control, saving energy and costs. MiniCombiValves and combi valves combine three functions: a control valve for controlling the volumetric ow, an adjusting mechanism for a presettable volumetric ow and a differential pressure controller for balancing pressure uctuations in the hydraulic system. They also ensure load-independent, automatic hydraulic balancing of heating and ventilation plants. Whats more, they prevent rooms and zones from over- or undersupply, enhance comfort and allow particularly energy-efcient applications. In addition, valve characteristics for linear or continuous supply of heating and cooling energy via air heating and air cooling coils contribute to energy efciency. Products with long-term investment protection When you select valves and actuators for room and zone applications, you rely on rugged products manufactured according to strict quality guidelines that ensure a long service life and reliable operation. They meet European and international standards, such as eu.bac and EN 215. Thanks to backward compatibility, the products can be replaced seamlessly even after many years of operation.

12

Generation Distribution

Consumption/Use

Intelligent comfort when it matters Quiet operation and fast and accurate control ensure optimum comfort. Practical in every respect With Acvatix you show your sense of responsibility for the environment through the environmentally compatible and recyclable materials used in accordance with Siemens norms. The product range also includes actuators with halogen-free cables that act ame-retardant in case of a re and avoid the emission of toxic gases. That reduces the risk for people and the environment. Naturally, the valves and actuators for room and zone applications are also developed and produced in compliance with environmental standards such as RoHS.

Furthermore, you benet from practical handling and freedom from maintenance. The products can be installed and commissioned quickly with little effort. Manual operation without tools simplies commissioning and ensures operation in unforeseen situations, providing ideal conditions for service.

Highlights
Valves and actuators can be combined in a number of ways for all room and zone applications High energy and cost savings, e.g. through optimum design, automated stroke adaptation and simplied automatic hydraulic balancing Well-being and comfort owing to excellent control performance and noiseless operation Low space requirements thanks to compact design Auxiliary functions for convenient operation and reliable room comfort Ease of service and installation and high degree of environmental compatibility

13

Elite line
Typical applications Terminal units Induction units Chilled ceilings Actuators SSB.. Data sheet N4891 5.5 mm 200 N 200 N

Operating voltage AC 230 V AC 24 V AC/DC 24 V PN 16 Data sheet

Positioning signal 3-position 3-position 0...10 V

Positioning time [s] 150 150 75

Auxiliary switch

SSB31 SSB81 SSB61 ps [kPa] 725 725 350 350 300

SSB31.1 SSB81.1 pmax [kPa] 400 400 350 350 300 400 400 350 350 300 400 400 400 350 350

1110 C G DN [inch] N4845 VVP45.10-.. 10 G B VVP45.10-.. 10 G B VVP45.15-.. 15 G B VVP45.20-.. 20 G 1B VVP45.25-.. 25 G 1B VXP45.10-.. 10 G B VXP45.10-.. 10 G B VXP45.15-.. 15 G B VXP45.20-.. 20 G 1B VXP45.25-.. 25 G 1B VMP45.10-.. 10 G B VMP45.10-.. 10 G B VMP45.10-.. 10 G B VMP45.15-.. 15 G B VMP45.20-.. 20 G 1B VVP45..S, VMP45..S with Conex compression ttings, kvs = 0.63 / 1 / 1.6 / 2.5 m/h

kvs [m/h] 0.25 / 0.4 / 0.63 1 / 1.6 2.5 4 6.3 0.25 / 0.4 / 0.63 1 / 1.6 2.5 4 6.3 0.25 / 0.4 0.63 / 1 1.6 2.5 4

Standard line
Typical applications Terminal units Induction units Chilled ceilings Actuators STP21../71.. STP72E.. SFP.. SSP.. STS61.. Operating voltage AC 230 V Data sheet N4878 N4876 N4865 N4864 N4880 Positioning signal 2-position 2-position 3-position 2-position 3-position 3-position 010 V 2-position/PDM 2-position/PDM 0...10 V DN 10 10 10 15 20 10 10 10 15 20 10 10 10 15 G [inch] G B G B G B G B G 1B G B G B G B G B G 1B G B G B G B G B 2.5 mm 105 N 105 N 135 N 160 N

Positioning time [s] 180 10 150 10 43 150 < 150 180 180 34 kvs [m/h] 0.25 / 0.4 0.63 / 1 1.6 2.5 4 0.25 / 0.4 0.63 / 1 1.6 2.5 4 0.25 / 0.4 0.63 / 1 1.6 2.5 STP21 STP71 STP72E ps [kPa] 700 250 150 150 100 STS61 pmax [kP a] 400 250 150 150 100 400 250 150 150 100 400 250 150 150 SFP21/18 SFP71/18 ps [kPa] 1000 500 300 300 175 SSP31 SSP81.04 SSP81 SSP61 pmax [kPa] 400 400 300 300 175 400 400 300 300 175 400 400 300 300

AC 24 V

AC/DC 24 V

PN 16 Data sheet

1110 C N4847 VVP47.10-.. VVP47.10-.. VVP47.10-.. VVP47.15-.. VVP47.20-.. VXP47.10-.. VXP47.10-.. VXP47.10-.. VXP47.15-.. VXP47.20-.. VMP47.10-.. VMP47.10-.. VMP47.10-.. VMP47.15-..

.. = kvs value

Union nuts for threaded valves


Union nuts for threaded valves 14 See page 21

3 2

P+ M p1
1 5 1 2 4 3

P-

p2

p3

P+/P-

The combi valves VPI45.. combine three functions: a control valve [3] for controlling the temperature (via the room controller), an adjusting mechanism [2] with a scale for a presettable volumetric flow, a differential pressure controller [4] for balancing pressure fluctuations in the hydraulic system or across the control valve. The mechanical series-connected differential pressure controller keeps the differential pressure (p1 p2) constant across the valve and thus the set volumetric flow also. The desired maximum volumetric flow can be set with the adjusting mechanism [2]. The room controller (not shown) provides constant temperature control together with the SSD.. actuators. The VPI45..Q combi valves have pressure test points (P+, P-) for measuring and monitoring the differential pressure across the valve during commissioning.

Combi valves
Typical applications Terminal units Chilled ceilings Actuators SSD.. Data sheet N4861 5.5 mm 250 N

Positioning signal 3-position 3-position 0...10 V 0...10 V 2...10 V 1) Selectable: linear or equal-percentage valve characteristic 1120 C DN N4853 VPI45.15F0.5 15 VPI45.15F0.5Q 2) 15 VPI45.15F1.5 15 VPI45.15F1.5Q 15 VPI45.20F0.9 20 VPI45.20F0.9Q 20 VPI45.20F2 20 VPI45.20F2Q 20 VPI45.25F1.5 25 VPI45.25F1.5Q 25 VPI45.25F2 25 VPI45.25F2Q 25 VPI45.32F3 32 VPI45.32F3Q 32 2) The VPI45..Q types are tted with pressure testing points PN 25 Data sheet Rp [inch] Rp Rp Rp Rp Rp Rp Rp Rp Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1

Operating voltage AC 230 V AC 24 V AC/DC 24 V

Positioning time [s] 150 150 75 75 75 Vmin [l/h] 90 90 290 290 160 160 350 350 280 280 350 350 560 560 V [l/h] 620 620 1730 1730 1050 1050 2040 2040 1720 1720 2040 2040 3050 3050 pmin [kPa] 16 16 18 18 16 16 22 22 16 16 22 22 18 18

SSD31 SSD81 SSD61 SSD61EP 1) SSD61.2 pmax [kPa] 400 400 400 400 400 400 400 400 400 400 400 400 400 400

15

TRV line
Typical applications Radiators Actuators RTN.. Data sheet N2111

Thermal Typical applications Radiators Actuators STA21../71.. STA72E.. SSA.. STS61.. STP21../71.. STP72E.. Data sheet N4877 N4875 N4893 N4880 N4878 N4876 Positioning Operating voltage Positioning time [s] signal AC 230 V 2-position 180 3-position 150 AC 24 V 3-position 150 0...10 V < 150 AC/DC 24 V 2-position/PDM 180 2-position/PDM 180 0...10 V 34 Normally open/normally closed (for radiator valves) DIN N2105 VDN110 VDN115 VDN120 VEN110 VEN115 VEN120 NF N2106 VDN210 VDN215 VDN220 VEN210 VEN215 VEN220 VUN210 VUN215 NF VPD210A-.. VPD215A-.. VPD210B-200 VPD215B-200 VPE210A-.. VPE215A-.. VPE210B-200 VPE210B-200 DN 10 15 20 10 15 20 10 15 DN 10 15 10 15 10 15 10 15 Rp/R [inch] Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R [inch] Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R [inch] Rp/R Rp/R Rp/R 1 kv [m/h] 0.090.63 0.100.89 0.311.41 0.090.63 0.100.89 0.311.41 0.14...0.60 0.13...0.77 V [l/h] 25...318 25...318 95...483 95...483 25...318 25...318 95...483 95...483 kv [l/h] 0.25...1.9 0.25...2.6 0.25...2.6 pw [kPa] 5 5 10 10 5 5 10 10

RTN51 RTN51G 105 N 100 N

RTN71 2.5 mm 105 N

RTN81

105 N

STA21 STA71 STA72E NC

SSA31 SSA81 SSA61 pmax [kPa] 60 60 60 60 60 60 60 60 pmax [kPa] 200 200 200 200 200 200 200 200 pmax [kPa] 150 150 150

STS61 NC/NO

STP21 STP71 STP72E NO

PN 10 Data sheet

1...120 C

PN 10 Data sheet

1...90 C

DIN N2185 VPD110A-.. VPD115A-.. VPD110B-200 VPD115B-200 VPE110A-.. VPE115A-.. VPE110B-200 VPE115B-200

.. = Vnominal = 45 / 90 / 145 l/h PN 10 Data sheet 1...110 C N2103 VD115CLC VD120CLC VD125CLC DN 15 20 25

Adapters for valves of other manufacturers


AV.. adapters for Siemens actuators for TRV valves of other manufacturers AV51 AV52 AV53 AV54 AV55 AV56 AV57 AV58 AV59 AV60 AV61

Beulco 1) Adapter thread


1)

Comap M28x1.5

Danfoss RA 2000

Danfoss RAVL

Danfoss RAV

Giacomini

Herz M28x1.5

Oventrop < 2002 M30x1

Vaillant

TA < 2002 M28x1.5

MMA Markaryd M28x1.5

M30x1

Not to be used with RTN.. (distributor for underoor heating systems)

Connection (M30x1.5) to valves of other manufacturers, without adapter: Heimeier, Cazzaniga, Junkers, Oventrop M30x1.5 (since 2001), Honeywell Braukmann, TA type TBV-C, MNG, Beulco new

16

TRV line
Typical applications Radiator valves for manual operation Typical applications Radiator lockshield valves

PN 10 Data sheet

1120 C N2104 VDN10M VDN15M VDN20M VEN10M VEN15M VEN20M

DN 10 15 20 10 15 20

Rp/R [inch] Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R

kv [m3/h] 01.58 02.50 03.65 02.46 02.88 05.34

ps [kPa] 60 60 60 60 60 60

pv100 [kPa] 5...20 1) 5...20 1) 5...20 1) 5...20 1) 5...20 1) 5...20 1)

PN 10 Data sheet

1120 C N2107 ADN10 ADN15 ADN20 AEN10 AEN15 AEN20

DN 10 15 20 10 15 20

Rp/R [inch] Rp/R Rp/R Rp/R Rp/R Rp/R Rp/R

kv [m3/h] 01.8 02.5 03.0 01.8 02.5 03.0

Accessories for radiator valves


Compressing ttings for VDN1.., VEN1.., VDN2.., VEN2.., VUN2.., ADN.., AEN.. for copper and steel pipes for PEX plastic pipes for aluminum PEX pipes AVN10-12 AVN15P12 AVN15A14 AVN15-12 AVN15P14 AVN15A16 AVN15-14 AVN15-15 AVN15-16 Valve insert for VDN1.., VEN1.., VDN2.., VEN2.., VUN2.. AVN1

On /Off line
Data sheet N4863 N4877 N4875 N4880 N4860 Positioning Positioning Operating voltage signal time [s] AC 230 V 2-position 10 2-position 180 3-position/SPDT 3) 43 AC 24 V 2-position 10 010 V < 150 AC/DC 24 V 2-position/PDM 180 2-position/PDM 180 2) Not suited for radiator valves 3) SPDT= single-pole double throw (changeover switch) 1110 C Rp DN [inch] N4842 VVI46.15 15 Rp VVI46.20 20 Rp VVI46.25 25 Rp 1 VXI46.15 4) 15 Rp VXI46.20 4) 20 Rp VXI46.25 4) 25 Rp 1 VXI46.25T 5) 25 Rp 1 4) 70% kvs in bypass leakage rate in bypass 2...5% of kvs value 5) 100% kvs in bypass leakage rate in bypass 0.05% of kvs value
For noiseless operation, the value of 100 kPa should not be exceeded.

Typical applications Terminal units Domestic hot water storage tank charging Zone control

Actuators SFA.. STA21../71.. STA72E.. STS61.. SSA31.04 2)

2.5 mm 200 N 105 N 105 N 160 N

SFA21/18 SFA71/18 ps [kPa] 300 300 300 pmax [kPa] 300 300 300 300 300 300 200

STA21 STA71 STA72E ps [kPa] 200 200 200

STS61

SSA31.04 pmax [kPa] 200 200 200 200 200 200 200

PN 10 Data sheet

kvs [m/h] 2 3.5 5 2 3.5 5 5

17

Acvatix for refrigeration plants


Diverse choices for the supply and distribution of cooling energy or heat recovery Acvatix offers you hermetically sealed mixing, diverting and 2-port valves for refrigeration plants. These include refrigerant valves for expansion, hot-gas and suction throttle applications. All valves are compatible with standard controller signals 1) and operating voltages AC 24 V or DC 20...30 V. Greater energy efciency for refrigeration systems All Acvatix refrigerant valves save energy in the refrigeration plant, for example through their accurate superheat control also in part load situations. In addition, the ne stroke resolution enables exact positioning and thus accurate and efcient energy control. Thanks to the positioning time of less than one second, you can handle even the most difcult control tasks reliably while saving energy. Benet from your investments in the long term Rugged, long-lasting and backwardcompatible, the Acvatix refrigerant valves pay off for the long term. Their high efciency and hermetic sealing reduce the amount of refrigerant, the plant size and thus the investment costs. Integrated functions provide added value by protecting the refrigeration plants and buildings. For instance, automatic, fast shutoff in the event of a power failure prevents the temperature and pressure from reaching excessive levels a safety function that products of other manufacturers can only ensure with additional plant components. Features for various comfort options and customer benets To ensure that dynamic processes in refrigeration plants can be handled optimally with small amounts of refrigerants, all 2-port refrigerant valves have an integrated high-precision position controller with a stroke resolution of 1:1000. Simple and environmentally friendly The refrigerant valves are not only simple to install and maintenance-free, but also environmentally compatible: In all actuators the core is completely surrounded by a pressure tube. The magnet coil is located outside the refrigerant circuit, therefore the system is hermetically sealed. The magnet coil generates a magnetic eld that is transmitted through the pressure tube, causing the core to move and thus the valve to travel. Refrigerant valves from Siemens do not have static or dynamic seals that could release refrigerants into the environment in the event of damage.

Highlights
Hermetically sealed refrigerant valves also in IP65 design Energy savings through accurate superheat control, very ne stroke resolution and positioning time < 1 second Long-term investment protection thanks to long service life, backward compatibility and protection functions Vibration-free operation, safe in the event of a power failure, and control of dynamic processes Ease of service and installation, and high degree of environmental compatibility

1)

DC 0...10 V; DC 0...20 mA; DC 2...10 V; DC 4...20 mA

18

Refrigerant valves
Typical applications Expansion, direct/indirect hotgas and hot-gas distribution applications Suction gas applications Condensate mixing Brine plants PN 32 Data sheet -40100 C N4731 Valve M2FP03GX MVL661.. MVS661..N M3FB..LX.. M3FK..LX.. Operating voltage Positioning signal AC 24 V AC/DC 24 V AC/DC 24 V AC 24 V AC 24 V 010 V, 420 mA, 0...20 Phs 010 V, 210 V, 020 mA, 420 mA 010 V, 210 V, 020 mA, 420 mA 010 V, 420 mA, 020 Phs 010 V, 420 mA, 020 Phs kvs [m/h] Auxiliary functions Minimum stroke setting Minimum stroke setting pmax [kPa]

M2FP03GX

Pilot valve

0.3

1800

PN 40 Data sheet

-40120 C N4714 MVL661.15-0.4 MVL661.15-1.0 MVL661.20-2.5 MVL661.25-6.3 MVL661.32-12

DN Connection 15 15 20 25 32 Sleeve Sleeve Sleeve Sleeve Sleeve

Inner [inch] 1 1 Inner [mm] 26 26 26 26 26 Inner [inch] 1 1 1 2 Inner [inch] 1 1 Outer [mm] 33.7 33.7 33.7 33.7 33.7

kvs [m/h] 0.4 1 2.5 6.3 12 kvs [m/h] 0.16 0.4 1 2.5 6.3 kvs [m/h] 0.6 1.5 3 5 8 12 20 30 kvs [m/h] 0.6 1.5 3 5 8 12

kvs reduced [m/h] 0.25 0.63 1.6 4 7.6 kvs reduced [m/h] 0.1 0.25 0.63 1.6 4 Liquid pmax [kPa] 200 200 200 200 200 200 200 200

pmax [kPa] 2500 2500 2500 2500 200 pmax [kPa] 2500 2500 2500 2500 2500 Gas pmax [kPa] 800 800 800 800 800 800 800 800 pmax [kPa] 2200 2200 2200 1800 1200 800

PN 40 Data sheet

-40120 C N4717 MVS661.25-016N MVS661.25-0.4N MVS661.25-1.0N MVS661.25-2.5N MVS661.25-6.3N

DN Connection 25 25 25 25 25 Weldable Weldable Weldable Weldable Weldable

PN 32 Data sheet

-40120 C DN Connection N4722 M3FK15LX06 M3FK15LX15 M3FK15LX M3FK20LX M3FK25LX M3FK32LX M3FK40LX M3FK50LX 15 15 15 20 25 32 40 50 Sleeve Sleeve Sleeve Sleeve Sleeve Sleeve Sleeve Sleeve

PN 40 Data sheet

-40120 C N4721 M3FB15LX06/A M3FB15LX15/A M3FB15LX/A M3FB20LX/A M3FB25LX/A M3FB32LX

DN Connection 15 15 15 20 25 32 Sleeve Sleeve Sleeve Sleeve Sleeve Sleeve

19

Acvatix for industrial HVAC plants and special applications


Valves and actuators for stability, accuracy and reproducibility The 2-port and 3-port valves 1) tted with magnetic actuators meet the demanding control and hydraulic requirements when it comes to industrial processes that require specic room air conditions and for special applications such as motor test beds. They feature very short positioning times, high stroke resolution and large rangeability. The control response is unique under all load conditions and also extremely stable in low load situations. Energy efciency through accuracy and speed Accurate and very fast positioning plus ne stroke resolution enable precise and energy-efcient energy control. Extremely short positioning times ensure that even the most difcult control tasks can be handled reliably, for example in plants using plate heat exchangers. High investment protection and comfort based on broad experience With these Acvatix valves, you can also rely on long-lasting quality and security. They are developed, manufactured and systematically tested in accordance with international standards by Siemens. As a result, they meet European and international standards and have proven themselves millions of times in plants throughout the world. Their integrated position feedback enables efcient plant monitoring and rapid troubleshooting. In addition, the valves automatically close quickly and reliably in the event of a power failure. This is convenient, protects production processes and thus helps protect your investment. Environmentally friendly and easy to use Because they comply with environmental and production standards, the valves tted with magnetic actuators meet all requirements. In addition, you save a considerable amount of time, effort and costs due to simple planning, installation and commissioning plus low maintenance.

Highlights
2-port and 3-port valves tted with magnetic actuators for demanding control and hydraulic requirements Energy efciency through accuracy and speed (< 2 seconds) Long-lasting quality and security thanks to in-house production, in-depth experience and special functions Safety functions the valve closes reliably in the event of a power failure Environmentally friendly and easy to use

1)

Compatible with the standard controller signals DC 0...10 V, DC 0...20 mA, DC 2...10 V and DC 4...20 mA and operating voltages AC 24 V or DC 20...30 V

20

2-port and 3-port valves for HVAC plants and special applications
Typical applications Fast-acting heat exchanger control High-precision process control P = media containing mineral oil PN 16 Data sheet 1130 C N4455 MXF461.15-..P MXF461.20-5.0P MXF461.25-8.0P MXF461.32-12P MXF461.40-20P MXF461.50-30P MXF461.65-50P 1120 C N4454 M3P80FYP M3P100FYP DN 15 20 25 32 40 50 65 kvs [m/h] 0.6 / 1.5 / 3.0 5 8 12 20 30 50 ps [kPa] 300 300 300 300 300 300 300 pmax [kPa] 300 300 300 300 300 300 300 Note To be used as 2-port or mixing valves, not as diverting valves. Selectable valve characteristic: equalpercentage or linear. Valve type MXF461..P M3P..FYP Operating voltage AC 24 V AC 24 V Positioning signal 010 V, 210 V, 420 mA 010 V, 420 mA

80 100

80 130

300 200

300 200

Threaded 2-port and 3-port valves for HVAC plants and special applications
Typical applications High-precision process control Valve type MXG461..P MXG461S.. MXG462S.. Operating voltage AC 24 V AC 24 V AC/DC 24 V Positioning signal 010 V, 210 V, 420 mA 010 V, 210 V, 420 mA 010 V, 210 V, 020 mA, 420 mA G [inch] G 1B G 1B G 1B G 2B G 2B G 2B G [inch] G 1B G 1B G 1B G 2B G 2B kvs [m/h] 0.6 / 1.5 / 3.0 5 8 12 20 30 kvs [m/h] 1.5 5 8 12 30 Type sufx P, M

P = media containing mineral oil, M = silicon-free version PN 16 Data sheet 1130 C N4455 MXG461.15-..P MXG461.20-5.0P MXG461.25-8.0P MXG461.32-12P MXG461.40-20P PN 16 Data sheet MXG461.50-30P 1130 C N4465 MXG461S15-1.5 MXG461S20-5.0 MXG461S25-8.0 MXG461S32-12 .. = kvs value -20...130 C N4466 MXG462S50-30 DN 15 20 25 32 40 50 DN 15 20 25 32 50 ps pmax [kPa] [kPa] Note 300 300 300 300 300 300 300 300 300 300 To be used as 2-port or mixing valves, not as diverting valves. Selectable valve characteristic: equalpercentage or linear.

300 300 ps pmax [kPa] [kPa] Note 300 300 300 300 600 300 300 300 300 600 To be used as 2-port or mixing valves, not as diverting valves. Selectable valve characteristic: equalpercentage or linear. Parts that are in contact with medium in stainless steel.

Union nuts for threaded valves


Type G R, Rp Material [inch] [inch] Set of 2 Set of 3 ALG132 ALG133 G B R (externally threaded) Brass ALG142 ALG143 G B R (externally threaded) Brass ALG122 ALG123 G B Rp Malleable cast iron ALG152 ALG153 G 1B Rp Malleable cast iron ALG152B ALG153B G 1B Rp Brass G R ALG202 ALG203 G 1B Rp Malleable cast iron ALG202B ALG203B G 1B Rp Brass ALG252 ALG253 G 1B Rp 1 Malleable cast iron ALG252B ALG253B G 1B Rp 1 Brass G R ALG322 ALG323 G 2B Rp 1 Malleable cast iron Rp G ALG322B ALG323B G 2B Rp 1 Brass ALG402 ALG403 G 2B Rp 1 Malleable cast iron ALG402B ALG403B G 2B Rp 1 Brass ALG502 ALG503 G 2B Rp 2 Malleable cast iron Rp G Brass ALG502B ALG503B G 2B Rp 2 G d Type G d Material [inch] [mm] Set of 2 ALS152 G B 21.3 Steel, weldable G d ALS202 G 1B 26.8 Steel, weldable G d ALS252 G 1B 33.7 Steel, weldable Valve side: cylindrical thread G according to ISO 228-1, pipe side: ALG.. with cylindrical Rp- or tapered R-thread according to ISO 7-1 Pipe side: ALS.. with welded connection
d G

21

Sizing and selecting valves and actuators


Sizing and selection Correctly sized and selected valves and actuators make an important contribution to the hydraulic and thermal control stability of HVAC plants to optimum operation in all operating and load situations to the energy efciency of the entire HVAC plant HVAC Integrated Tool (HIT) The HVAC Integrated Tool relieves the burden on installers, consultants and planners both in routine tasks and in the time-consuming search for suitable products for controlling a HVAC or refrigeration system. It provides access to the existing range of valves, actuators, sensors, thermostats and variable speed drives from Siemens. The self-explanatory and user-friendly menu navigation is adapted to the typical workows of the industry and allows you an easy start. In addition to the CD version, the HIT is also available as an online version 1) which looks and functions in the same way. This means that all data on the product range and all stored documents are always up-to-date. When previous projects are accessed, the program also identies products that are no longer available, and suitable successor models can be found immediately with the help of the search function. Easy DATA Using the Easy DATA software tool, you can quickly and easily insert valves and actuators into your 2D and 3D CAD plans for HVAC and refrigeration systems. Easy DATA is available on CD and also offers you product labeling, tendering texts and data sheets. Valve slide rules The proven Acvatix valve slide rules simplify sizing and cover the selection for applications with water. For central HVAC plants: 0-91826-EN, for room and zone applications: 0-91827-EN.

Highlights
Fast, targeted planning and design of HVAC plants thanks to HIT Support in the selection of valves and actuators through HIT Fast creation of 2D and 3D CAD layout plans with Easy DATA Simple valve selection for water applications thanks to valve slide rules

1)

www.siemens.com/hit

22

House of valves

Consumption/Use
Chilled ceiling Typical for this application: small temperature differentials and large volumetric ow; demand for simple installation, stable and fast control, quiet and maintenance-free operation; PN 16 or PN 10 class, threaded 2-port valves; 3-position/ DC 010 V positioning signals. Fan coils Typical for this application: demand for simple installation, stable and fast control, quiet and maintenance-free operation; PN 16 class; threaded valves; various valve designs; 3-position/DC 010 V positioning signals; pluggable connecting cables in various lengths, also halogen-free versions; combi valves for energy-efficient operation of large plants.

Distribution
Air handling units Typical for these applications: heating coils: long operating times under part load conditions; fast-acting control (short valve positioning times); 2-port or 3-port valves. Cooling coils: long operating times under part load conditions; fast-acting control (short valve positioning times); 2-port or 3-port valves; safety function. Humidication: today preferably with steam (up to 140 C); safety function; 2-port valves; valve trim made from stainless steel. All applications and heat recovery (HR): DC 010 V positioning signals; flanged or threaded connections; PN 16 class. Domestic hot water Typical for these applications: fast-acting control (short positioning times); certied by DVGW 1) to confirm compliance with stringent hygiene requirements and to reduce the risk of legionella viruses in storage tanks; high temperature gradient in the valve; fail-safe; 3-position/DC 010 V positioning signals; threaded 3-port valves; PN 16 class.

Generation
Boiler plant Typical for this application: heat generation with minimum limitation of the return temperature (prevention of boiler corrosion); ruggedness for long service life; 3-position positioning signals; anged 3-port valves, buttery valves; PN 16 class. ) DVGW = German Technical and Scientic Association for Gas and Water Chiller plant Typical for this application: large, slow mass flows with small temperature differentials; quick changes in cooling requirements; closed circuits; DC 010 V positioning signals; anged 2-port or 3-port valves; PN 16 class.

Generation

Distribution

Consumption/Use

Valve sizing and actuator selection


Basic hydraulic circuit 1 Determine the type of hydraulic circuit For valve sizing relevant variable ow path Throttling circuit Injection circuit with 2-port valve Diverting circuit Injection circuit with 3-port valve Mixing circuit Mixing circuit with xed premixing

Primary pump Primary pump Primary pump Primary pump

HVAC plants and consumers


Heating Surface /oor heating Heating plant (primary) Zone control, heating Heating group Generation of heat energy Heat exchanger water-water Ventilation and air conditioning plants Air handling unit (AHU) Fan coil unit dehumidifying Cooling coil Reheating coil Preheating coil VAV Zone control Chiller plants Surface /oor cooling Generation of cooling energy Cooling towers Zone control, cooling District heating, cooling District heating, primary District heating, secondary District cooling, primary District cooling, secondary Domestic hot water (DHW) DHW uncommon uncommon uncommon uncommon dehumidifying outdated outdated outdated outdated uncommon outdated outdated uncommon outdated outdated outdated outdated outdated uncommon outdated uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon uncommon

Header
Differential pressure header Volumetric ow pressurized variable constant pressureless variable

Determination of kvs value


2 pVR or pMV typical range typical value Determine pV100 Calculate V100 pVR 10200 kPa 10200 kPa Use effective pVR value 1050 kPa 35 kPa 25 kPa 3 kPa 25 kPa 3 kPa pMV 515 kPa 8 kPa pV100 > pMV Q100 1.163T kvs =
V100 pV100 100

25 kPa 3 kPa

515 kPa 8 kPa

3 4

pV100

pVR 2

Water without anti-freeze V100 =

Water with anti-freeze V100 =

Q100 3600 cT

Determine kvs value Check resulting pV100

0.85 . kvs value

pV100 = 100

( )
V100 kVS

Selection of valve and actuator


7 8 9 Select suitable valve series Check valve authority Pv (control stability) Select actuator a) Type of valve (2-port, 3-port, 3-port with bypass) b) Connections (anged, threaded, soldered) pV100 PV = 0.250.8 pVR a) Operating voltage b) Positioning signal c) PN class e) Max/min medium temperature d) Nominal size DN f) Medium pV100 PV = 0.250.8 pV100 + pMV d) Spring return function e) Auxiliary functions

c) Positioning time

Check the working 10 range 11 Selection

a) Differential pressure pmax > pV0 Valve and suitable actuator

b) Closing pressure ps > H0

Size and select combi valves


Determine volumetric ow V 1 Determine Q100 Q100 2 Determine T T 3 Calculate V Water without anti-freeze V100 = Q100 1.163T Water with anti-freeze V100 =
Q100 3600 cT

Select combi valve and actuator Select suitable a) Type of valve (2-port) b) PN class c) Max/min medium temperature 4 combi valve d) Connection (threaded) e) Nominal size DN f) Medium 5 Determine presetting Determine presetting using the volumetric ow/dial table in data sheet N4853 6 Select actuator a) Operating voltage b) Positioning signal c) Positioning time d) Auxiliary functions a) p < pmax maximum permissible differential pressure across the valves control path, valid for the entire actuating range of the motorized valve 7 Check working range b) p > pmin minimum differential pressure required across the valves control path, so that the differential pressure regulator works reliably 8 Select actuator Combi valve and suitable actuator

Denitions
Abbr. p pmax pV0 pV100 ps pMV pVR pw T DN H0 kPa mWC kV k VS Controlled differential pressure Temperature spread Nominal size Shutoff head Unit of pressure Meter water column Nominal ow Nominal ow rate Spring return function PN Phs Pv Q100 V100 PN class Phase cut control signal Valve authority Rated capacity Volumetric ow Kinematic viscosity c Specic heat capacity Specic density kW m/h mm/s kJ/kgK kg/m V Differential pressure at nominal ow rate Closing pressure Term Differential pressure Unit kPa Denition Pressure differential between plant sections Maximum permissible differential pressure across the valves control path, valid for the entire actuating range of the motorized valve Maximum differential pressure across the valves closed control path Differential pressure across the fully open valve and the valves control path by a volumetric ow V100 Maximum permissible differential pressure at which the motorized valve will close securely against the pressure (close off pressure) Differential pressure across the variable ow path. Often pMV is not known, in which case typical values can be used. Differential pressure between ow and return Temperature differential between ow and return Characteristic for matching parts of the piping system The head generated by a pump at closed value, at a given speed and a given pump medium 100 kPa = 1 bar = 10 mWC Amount of cold water (530 C) passing through the valve at the respective stroke and at a differential pressure of 100 kPa (1 bar) Nominal ow rate of cold water (5...30 C) through the fully open valve (H100) at a differential pressure of 100 kPa (1 bar) Shutoff in the event of a power failure Characteristic relating to the combination of mechanical and dimensional properties of a component in the piping system DC 0...20 V Phs Ratio of differential pressure across fully open valve (H100) and differential pressure across valve and variable ow path. To ensure correct control, a minimum valve authority of 0.3 is required. Plants design capacity Volumetric ow with valve fully open (H100) In the case of kinematic viscosities up to 10 mm/s, no corrections are required. For the selection of actuating devices for kinematic viscosities above 10 mm/s, please contact your local Siemens branch ofce.

Maximum differential pressure kPa kPa kPa kPa kPa kPa kPa K m kPa m m/h m/h

Symbols
3-port valve, control path with equal-percentage valve characteristic, bypass with linear valve characteristic 3-port valve, control path with equal-percentage valve characteristic, bypass with linear valve characteristic with 70% of the kvs value. This compensates for the ow resistance of the heat exchange, so that the total volumetric ow V100 remains as constant as possible. 2-port valve, control path with equal-percentage valve characteristic 2-port valve, control path with linear valve characteristic 3-port, control path and bypass with linear valve characteristic. Bypass with 70% of the kvs value. This compensates for the ow resistance of the heat exchanger, so that the total ow amount V100 remains as constant as possible. 3-port valve, control path and bypass with linear valve characteristic 3-port valve, control path and bypass with equal-percentage valve characteristic

Recommended media
Mineral oil SAE05 SAE50 Water with anti-freeze 2) Diesel fuels based on mineral oil

Superheated steam

Type of connection

Safety refrigerants

Silicon-free grease

Low temperature hot water High temperature hot water

Media containing mineral oils

R717 (ammonia)

Saturated steam

Heat transfer oil

Cooling water )

Drinking water

Closed circuits

Chilled water

Open circuits

2-port valve

3-port valve

4-port valve

R744 (CO)

PN class

Brines

M3P..FY M3P..FYP MXF461.. MXF461..M MXF461..P MXG461.. MXG461B.. MXG461..M MXG461..P MXG461S.. MXG462S.. MVF461H.. VAI61.. VBF21.. VBG31.. VBI31.. VBI61.. VCI31.. VKF41.. VKF46.. VVF21.. VVF31.. VVF40.. VVF41.. VVF41..4 VVF41..5 VVF45.. VVF45..4 VVF52.. VVF52..A VVF52..G VVF52..M VVF61.. VVF61..2 VVF61..5 VVG41.. VVG44.. VVG55.. VXF21.. VXF31.. VXF40.. VXF41.. VXF41..4 VXF41..5 VXF61.. VXF61..2 VXF61..5 VXG41.. VXG41..01 1) VXG44.. VD1..CLC VDN../VEN../VUN.. VMP45.. VMP47.. VPD../VPE.. VPI45.. VVI46.. VVP45.. VVP47.. VXI46.. VXP45.. VXP47.. M2FP03GX M3FB..LX.. M3FK..LX.. MVL661.. MVS661..N

16 16 16 16 16 16 16 16 16 16 16 16 40 6 10 10 40 10 16 16 6 10 16 16 16 16 16 16 25 25 25 25 40 40 40 16 16 25 6 10 16 16 16 16 40 40 40 16 16 16 10 10 16 16 10 25 16 16 16 16 16 16 32 40 32 40 40

F F F F F ET ET ET ET ET ET F IT F ET IT IT IT F F F F F F F F F F F F F F F F F ET ET ET F F F F F F F F F ET ET ET ET ET ET ET ET IT IT ET ET IT ET ET S S S W

Central HVAC plants

Room and zone applications

Refrigeration systems

Recommendation: Water treatment according to VDI 2035, ) Sealed bypass, 2) e.g. ethylene and propylene glycols, ) open circuits IT = internally threaded connection, ET = externally threaded connection, F = flanged connection, S = soldered connection, W = welded connection

Air

Permissible medium temperature [C]

Generation

Distribution Consumption/Use
Domestic hot water (DHW)

Underoor heating

Air handling units

Cooling towers )

District heating

Heating groups

Chilled ceilings

Chiller plants

Zone control

Fan coil unit

Boiler plant

Radiators

Refrigeration systems 27

Room and zone applications

Central HVAC plants

VAV M3P.. FY M3P.. FYP MXF461.. MXF461..M MXF461..P MXG461.. MXG461B.. MXG461..M MXG461..P MXG461S.. MXG462S.. MVF461H.. VAI61.. VBF21.. VBG31.. VBI31.. VBI61.. VCI31.. VKF41.. VKF46.. VVF21.. VVF31.. VVF40.. VVF41.. VVF41..4 VVF41..5 VVF45.. VVF45..4 VVF52.. VVF52..A VVF52..G VVF52..M VVF61.. VVF61..2 VVF61..5 VVG41.. VVG44.. VVG55.. VXF21.. VXF31.. VXF40.. VXF41.. VXF41..4 VXF41..5 VXF61.. VXF61..2 VXF61..5 VXG41.. VXG41..01 1) VXG44.. VD1..CLC VDN../VEN../VUN.. VMP45.. VMP47.. VPD../VPE.. VPI45.. VVI46.. VVP45.. VVP47.. VXI46.. VXP45.. VXP47.. M2FP03GX M3FB..LX.. M3FK..LX.. MVL661.. MVS661..N

100

110

120

130

150

180

220

350

-40

-25

-20

-10

90

Answers for infrastructure.


Megatrends driving the future The megatrends demographic change, urbanization, climate change, and globalization are shaping the world today. These have an unprecedented impact on our lives and on vital sectors of our economy. Innovative technologies to answer the associated toughest questions Throughout a 160-year history of proven research and engineering talent, with more than 50,000 active patents, Siemens has continuously provided its customers with innovations in the areas of healthcare, energy, industry, and infrastructure globally and locally. Increase productivity and efciency through complete building life cycle management Building Technologies offers intelligent integrated solutions for industry, commercial and residential buildings, and public infrastructure. Over the entire facilitys life cycle, our comprehensive and environmentally conscious portfolio of products, systems, solutions, and services for low-voltage power distribution and electrical installation technology, building automation, re safety and security ensures the: optimum comfort and highest energy efciency in buildings, safety and security for people, processes, and assets, increased business productivity.

Siemens Switzerland Ltd Industry Sector Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel +41 41 724 24 24 Siemens Building Technologies Industry Sector Brunel House Sir William Siemens Square, Frimley Camberley Surrey, GU16 8QD United Kingdom Tel +44 1276 696000

Siemens Ltd Industry Sector Building Technologies Division Units 1006-10 10/F, China Resources Building 26 Harbour Road Wanchai, Hong Kong Tel +852 2870 7888

The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specied in each individual case at the time of closing the contract. Siemens Switzerland Ltd, 2010 Order no. 0-92205-en 01006

www.siemens.com/acvatix

Вам также может понравиться