Вы находитесь на странице: 1из 12

When it comes to reliability in security systems, our transformers provide the key

How we are working for you to maintain our leadership in the security transformer market
A critical factor in that leadership has been our ability to understand the needs of the market and keep up with technology. As a result, installers of all kinds of security systems know that they find exactly the correct ATC- FROST transformer to meet their needs. If they have any doubts, we will help them make the right choice. We can only do that by having a thorough knowledge of security applications.

Advanced technology Of course, knowledge of the application requirements is only part of the answer. The rest comes in our product development that has the primary goal of staying ahead technologically. For example, you will see on these pages many transformers designed specifically for security applications. Note in particular our new series of transformers combined with fusing and convenient terminations all mounted in a cabinet. This product has been designated FCS Series Camera Power Supply (See next page).

Specialized Software All of our transformers for security use are the product of modern design systems based on specialized computer software. In other words, many aspects of the transformers you see here are exclusive to ATC- FROST and not available anywhere else. We manufacture our transformers in two manufacturing plants that employ the latest production and testing equipment to produce superior products that meet ISO standards. So you know the security systems you install using our transformers will themselves be secure because of the high reliability we build into them.

Go with the leader and be secure. Install ATC-FROST transformers.

A new security panel for CCTV Cameras FCS Series Camera Power Supply
Application:
To provide simple 24 volt AC power for CCTV cameras. This economical yet professional approach in camera power will soon be expanded from the popular eight circuit 100VA shown, to 200VA, sixteen circuit model.

Features:
ULC Listed AC Power Supply s Fully rated power transformer s Fused outputs at 24VAC, 0.5 amps each s Spare fuses supplied s Front mounted 24 volt indicator LED s Screw terminal primary and secondary for trouble free connections s Attractive cream baked enamel panel, can be flush mounted between studs. Only 3.5 depth s Sturdy four point mounting s 8 X 1/2 knockouts. Two at each corner
s

120 Volt 60 Hz Primary


Cat. No. FCS824 FCS1624 VA 100VA 200VA Secontary (RMS) Volt Amps 8 x 24 16 x 24 0.5 0.5 High Dimensions (in) Wide Deep 11.75 11.75 3.5 3.5 lb. Weight Kg 3.7 4.4

11.75 11.75

8.2 9.7

TCE
Enclosed Mounting
Control Circuit Transformers Application:
Enclosed to allow mounting of control circuit transformers outside of any other electrical enclosure, as coil protection and access knockouts for cable are integrally provided.

Features:
Attractive ASA61 grey baked enamel covers with 1/2 conduit knockouts. Size Reduced (SR) enclosures are available on: 100VA*, 150VA*, 200VA* models. Add suffix SR. Fully varnish impregnated core and coil assembly for quiet operation. CSA-NRTL/C certified, LR16597. UL recognized to 500VA, E105782. Leads and screw terminals are used for ease of installation. Dielectric tested to UL/CSA standards. Models from 100VA to 1000VA. 60Hz rated.
NRTL/C

Primary Sec. Volts Volts


120 12/24 24 120 24 120 24 120 24 120 120/240 24 120 240 120/240 24 120 240 120/240 24 120 240 120/240 24 120 240 120/240

100VA*
TCE10012D-1 TCE10024-1 TCE100120-1 TCE10024-2 TCE100120-2 TCE10024-3 TCE100120-3 TCE10024-4 TCE100120-4 TCE100120D-4 TCE10024-5 TCE100120-5 TCE100240-5 TCE100120D-5 TCE10024-6 TCE100120-6 TCE100240-6 TCE100120D-6 TCE10024-7 TCE100120-7 TCE100240-7 TCE100120D-7 TCE10024-9 TCE100120-9 TCE100240-9 TCE100120D-9

150VA*
TCE15012D-1 TCE15024-1 TCE150120-1 TCE15024-2 TCE150120-2 TCE15024-3 TCE150120-3 TCE15024-4 TCE150120-4 TCE150120D-4 TCE15024-5 TCE150120-5 TCE150240-5 TCE150120D-5 TCE15024-6 TCE150120-6 TCE150240-6 TCE150120D-6 TCE15024-7 TCE150120-7 TCE150240-7 TCE150120D-7 TCE15024-9 TCE150120-9 TCE150240-9 TCE150120D-9

200VA*
TCE20012D-1 TCE20024-1 TCE200120-1 TCE20024-2 TCE200120-2 TCE20024-3 TCE200120-3 TCE20024-4 TCE200120-4 TCE200120D-4 TCE20024-5 TCE200120-5 TCE200240-5 TCE200120D-5 TCE20024-6 TCE200120-6 TCE200240-6 TCE200120D-6 TCE20024-7 TCE200120-7 TCE200240-7 TCE200120D-7 TCE20024-9 TCE200120-9 TCE200240-9 TCE200120D-9

250VA
TCE25012D-1 TCE25024-1 TCE250120-1 TCE250120-2 TCE250120-2 TCE25024-3 TCE250120-3 TCE25024-4 TCE250120-4 TCE250120D-4 TCE25024-5 TCE250120-5 TCE250240-5 TCE250120D-5 TCE25024-6 TCE250120-6 TCE250240-6 TCE250120D-6 TCE25024-7 TCE250120-7 TCE250240-7 TCE250120D-7 TCE25024-9 TCE250120-9 TCE250240-9 TCE250120D-9

350VA
TCE35012D-1 TCE35024-1 TCE350120-1 TCE350120-2 TCE350120-3 TCE350120-4 TCE350120D-4 TCE35120-5 TCE350240-5 TCE350120D-5 TCE350120-6 TCE350240-6 TCE350120D-6 TCE350120-7 TCE350240-7 TCE350120D-7 TCE350120-9 TCE350240-9 TCE350120D-9

500VA
TCE50012D-1 TCE50024-1 TCE500120-1 TCE500120-2 TCE500120-3 TCE500120-4 TCE500120D-4 TCE500120-5 TCE500240-5 TCE500120D-5 TCE500120-6 TCE500240-6 TCE500120D-6 TCE500120-7 TCE500240-7 TCE500120D-7 TCE500120-9 TCE500240-9 TCE500120D-9

750VA

1000VA

TCE750120-1 TCE750120-2 TCE750120-3 TCE750120-4 TCE750120D-4 TCE750120-5 TCE750240-5 TCE750120D-5 TCE750120-6 TCE750240-6 TCE750120D-6 TCE750120-7 TCE750240-7 TCE750120D-7 TCE750120-9 TCE750240-9 TCE750120D-9

TCE1000120-1 TCE1000120-2 TCE1000120-3 TCE1000120-4 TCE1000120D-4 TCE1000120-5 TCE1000240-5 TCE1000120D-5 TCE1000120-6 TCE1000240-6 TCE1000120D-6 TCE1000120-7 TCE1000240-7 TCE1000120D-7 TCE1000120-9 TCE1000240-9 TCE1000120D-9

208 240 277

347

416

480

600

Dimensions
C

VA A B
8.20 8.50 9.25 8.75 9.25 10.25 11.00 12.00

C
3.50 3.50 3.50 4.20 4.20 4.20 5.30 5.30

D
3.20 3.20 3.20 3.75 3.75 3.75 3.50 3.50

*SR B E

E B A D

Standard TCE mounting

100VA 150VA 200VA 250VA 350VA 500VA 750VA 1000VA

3.88 3.88 3.88 4.50 4.50 4.50 4.40 4.40

7.50 5.75 4.50 7.75 6.25 5.00 8.50 6.75 5.50 8.00 8.50 9.50 10.00 11.00

E A D

TCE (SR) mounting

Class 2
Selection Guide
Two Categories to Choose From:
Fully Certified Class 2 Transformers A Fully Certified Class 2 transformer is designed for permanent, wired-in, field applications where the extra reliability of professional wiring practices and electrical box mounting is required or desired. Fully certified models have 1/2 conduit nipple or 4 plate mounting. ATC-FROST series to review are FTC, FTD and FTK. Plug-in Class 2 Transformers Plug-in versions of Class 2 transformers are often requested because the need for a qualified technician to install this type of transformer is not required. Both Direct Plug-in and Cord Connected Plug-in models need additional certification due to their portable nature. ATC-FROST models are all subsequently certified to C22.2 No. 223-M91 and the Direct Plug-in models are also CSA (NRTL/C) certified to UL1310. ATC-FROST series to review are FPS and FTA. Doing their Job As mentioned under Where and why are Class 2 Transformers Required?, a Class 2 transformer is DESIGNED TO FAIL in the event of an overload or short circuit. Typical fault conditions which could produce a transformer failure include, but are not limited to, the following: improper voltage section; too many devices powered by one transformer; a pinched or stapled wire; a wiring mistake; or a faulty connected device. ATC-FROST is unable to warranty a Burnt-out Class 2 transformer that has obviously done its job by protecting a fault condition. A failed Class 2 transformer can be recognized by one of two methods and should not be returned for replacement or credit. Most models will show open on the primary leads or plug-in blades with a simple ohmmeter check A limited number of models marked Fused Secondary Do Not Short will show open on the secondary terminals with an ohmmeter check.

What is a Class 2 Transformer?


In practical terms, this type of transformer has protection designed in to limit its output current to a maximum of 8 amps at one minute under all loading conditions including a short circuit. The maximum secondary voltage may not exceed 30 VRMS when the primary is connected to its rated input values. To meet approval, a Class 2 transformer may not show any evidence of a fire or shock hazard, even as it fails to operate.

Energy Limiting and Non-energy Limiting


An Energy-Limiting Class 2 transformer has enough winding impedance to limit its output current. Typically poor voltage regulation is to be expected because of this high impedance but is not normally a concern. An energy-limiting transformer may or may not also be provided with an overtemperature device to limit its maximum temperature. A Non-energy Limiting Class 2 transformer does not have enough winding impedance to limit the output current and is equipped with a fuse or other overcurrent device. Typically better voltage regulation is to be expected as the winding impedance can be similar to a conventional power transformer.

Where and Why are Class 2 Transformers Required?


A Class 2 transformer is considered to be a safety device and indeed is a requirement in the Electrical Code for supplying power to a Class 2 circuit. These circuits typically consist of lightweight, unprotected bell wiring, and devices which often have exposed or easily accessible terminals. Because of the risk of mechanical damage or overloading, the transformer protecting the Class 2 circuit is designed to fail in a safe manner and guard against fire and shock risk. Typical installations which employ Class 2 wiring methods include: Security Systems Humidifiers Central Vacuum Systems P.O.P. Displays Door Chimes Intercoms Thermostats Vending Machines Garage Door Openers Fire Alarm Sensors Remote Controls Lighting Controls

FTC-FTK
Energy Limiting Transformers
Fully Certified Class 2 Transformers - Wired-in (Metal) Features:
Rugged all steel design provides excellent heat dissipation and electromagnetic shielding. Fully threaded, steel conduit nipple provides strong positive mounting. Secondary wiring terminals are also available in combination screw/.25 male quick connects. Vacuum varnish impregnated and oven baked to ensure quiet, trouble free operation. Optional mounting accessories for panel box installation. Fuseless energy limited winding except as noted*. Most models are North American Approved by CSA (NRTL/C) or UL (see table below). Two Mounting Styles

1. Nipple

2. Foot/Nipple

NRTL/C

Options:
FA112 mounting bracket (sold separately) 2.25 x 2.0 x 0.8 c/w K.O. for nipple provides 2.0 panel mounting centres. -Q quick connect male terminals .25 in combination with screw terminals. -L secondary leads extending through fibre in place of terminals. -C secondary leads extending through slotted end shell. -F secondary fuse block for Class 2 circuit only.

Shown with FA112 Mounting Bracket

Shown with Optional Screw/.25 Q.C.

Models 120 Volt 60Hz Primary


Cat. No.
FTC 1024 FTC 1210 FTC 1216 FTC 1224 FTC 2012 FTC 2014 FTC 2016 FTC 2018 FTC 2024 FTC 2024/16/8 FTC 3716 FTC 3718 FTC 4012* FTC 4016 FTC 4018 FTC 4024 FTC 4024UL FTC 5024

VA
10 12 12 12 20 20 20 20 20 20/17/13 37 37 40 40 40 40 40 50

Secondary (RMS) Sec (RMS) Volts Amps. N.L. Volts


24 0.42 10 1.20 16 0.75 24 0.50 12 1.67 14 1.43 16 1.25 18 1.11 24 0.83 24/16/8 .83/1.0/1.6 16.5 2.24 18 2.06 12 3.33 16.5 2.42 18 2.22 24 1.67 24 1.67 25 2.00 29.5 13.9 21.7 29.5 14.1 16.8 18.9 21.5 29.0 28/16/9.4 19.5 21.1 13.7 19.7 21.7 28.3 28.3 28.5

CSA
X X X X X X X X X X X X X X X X X X

Approvals UL NRTL/C
X X X X X X X X X X X X X X X X X X

Style
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

Mounting Style High Wide


2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1.9

Deep
1.9 1.9 1.9 1.9 2.0 2.0 2.0 2.0 2.0 2.0 2.3 2.3 2.3 2.3 2.3 2.3 2.3 3.1

Weight lb. Kg
.83 .83 .83 .83 1.0 1.0 1.0 1.0 1.0 1.0 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.8 (.38) (.38) (.38) (.38) (.46) (.46) (.46) (.46) (.46) (.46) (.60) (.60) (.60) (.60) (.60) (.60) (.60) (.81)

Other Primary Voltages


Cat. No. Primary Volts Rating Freq.
60 50/60 60 50/60 60 60 60

*FTC 4012 is classed as a non-energy limiting Class 2. It uses a fuse for current limiting.

VA
20 20 20 37 40 40 40

Secondary (RMS) Sec (RMS) Volts Amps. N.L. Volts


16 24 24 16 24 24 24 1.25 0.83 0.83 2.25 1.67 1.67 1.67 18.9 29.7 29.0 19.1 28.3 28.3 27.6

Approvals Mounting Style CSA UL NRTL/C Style High Wide Deep


X X X X X X X 1 1 1 1 1 1 1 2.0 2.0 2.0 2.0 2.0 2.0 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.7 2.0 2.0 2.0 2.3 2.3 2.3 2.5

Weight lb. Kg
1.0 1.0 1.0 1.3 1.3 1.3 1.5 (.46) (.46) (.46) (.60) (.60) (.60) (.68)

FTC 2016-3 240 FTK 2024 100 FTC 2024-3 240 FTK 3716-3 230 FTC 4024-3 240 FTC 4024-8 208/240 FTC 4024-10 120/208/240

FTC-FTD-FTK
Energy and Non-energy Limiting Transformers
Fully Certified Class 2 Transformers - Wired-in (Metal) Heavy Duty
Two Mounting Styles

Application:
These heavy duty models have been designed for applications which require higher inrush capabilities for the transformer. Some typical examples include: Low voltage lighting controls where large contactors are required to pull in, and Security installations with multiple devices on the same circuit.

Features:
Rugged all steel design provides excellent heat dissipation and electromagnetic shielding. Fully threaded, steel conduit nipple or 4 plate for electrical box mounting. Secondary wiring terminals are also available in combination screw/.25 male quick connects. Vacuum varnish impregnated and oven baked to ensure quiet, trouble free operation. FTD models are Energy Limited designs and also include an overtemperature thermostat. FTC75 and FTK75 models are classed as Non-energy Limiting Class 2 as they use a trip-free circuit breaker to limit the current. Most models are North American Approved by CSA (NRTL/C) or UL (see table below).

1. Nipple

Options:
FA112 mounting bracket (sold separately) 2.25 x 2.0 x 0.8 c/w K.O. for nipple provides 2.0 panel mounting centres. -Q quick connect male terminals 0.25 in combination with screw terminals. -L secondary leads extending through fibre in place of terminals. -C secondary leads extending through slotted end shell. -F secondary fuse block for Class 2 circuit only.

2. 4 Plate

NRTL/C

Models
Cat. No.
FTD 4024 FTD 4024-3 FTD 4024-4 FTD 4024-5 FTC 7516 FTK 7516-3 FTC 7524 FTK 7524-3

Primary Volts
120 240 277 347 120 230 120 230

Rating Freq.
60 60 60 60 60 50/60 60 50/60

VA
40* 40* 40* 40* 75 75 75 75

Secondary (RMS) Sec (RMS) Volts Amps. N.L. Volts


24 24 24 24 16 16 24 24 1.67 1.67 1.67 1.67 4.69 4.69 3.13 3.13 29.1 29.4 29.4 28.8 17.7 17.9 26.4 26.1

Approvals Mounting Style CSA UL NRTL/C Style High Wide Deep


X X X X X X X X X X X X X X 1 1 1 1 2 2 2 2 2.6 2.6 2.6 2.6 3.7 3.7 3.7 3.7 3.1 3.1 3.1 3.1 4.2 4.2 4.2 4.2 2.9 2.9 2.9 2.9 4.2 4.2 4.2 4.2

Weight lb. Kg
2.2 2.2 2.2 2.2 3.1 3.1 3.1 3.1 (.99) (.99) (.99) (.99) (1.4) (1.4) (1.4) (1.4)

*FTD 40VA models have a 75VA short duration capacity.

FPS
Energy Limiting Transformers
Direct Plug-in Class 2 Transformers Features:
Rugged, high-impact, flame retardant thermoplastic enclosure. Smooth, attractive lines with no sharp corners. Secondary screw terminals are hidden and protected from accidental shorting. Plugs into North American standard duplex receptacle. Unique additional support pin on 40VA models. Flexible secondary line cord, with or without jack, is available for special applications. North American approved by CSA (NRTL/C) to C22.2 No. 223-M91 and UL1310. LR67731. Most models utilize fuseless, energy-limiting design*.

20VA Size A

Models 120 Volt - 60Hz


Cat. No.
FPS2012 FPS2014 FPS2016 FPS2018 FPS2024 FPS4012* FPS4016* FPS4024

NRTL/C

VA
20 20 20 20 20 40 40 40

Secondary (RMS) Volts Amps.


12 14 16 18 24 12.5 16.5 24 1.67 1.43 1.25 1.11 0.83 3.20 2.42 1.67

Secondary (RMS) N.L. Volts


13.8 15.9 18.4 21.3 27.9 13.8 18.2 27.4

Size
A A A A A B B B

Weight lb.
.9 .9 .9 .9 .9 1.6 1.6 1.6

40VA Size B Kg
.41 .41 .41 .41 .41 .73 .73 .73

*FPS4012 and FPS4016 utilize a fuse for current limiting.

Dimensions - Size A & (B)

Other Available Styles

3.2" (3.7")

2.0" (2.2") 2.3" (2.7")

FTA
Energy and Non-energy Limiting Transformers
Cord Connected Plug-in Class 2 Transformers Application:
These cord connected models provide a safe, convenient plug-in method for some popular models of our wire-in series.

Features:
Rugged steel enclosure in two sizes. See dimension table below. 18 line cord is standard. Longer cords are available on special order. FTA 75 models also have a 1/2 conduit knockout for optional hard wiring of the primary. 4 protective rubber feet and keyhole mounting slots. FTA3716 is an attractive two-tone beige and black. FTA 75 models are painted ASA 61 grey. CSA certified to C22.2 No.223-M91. 37VA is an energy-limited design. 75VA utilizes a trip-free circuit breaker for current limiting. LR67731.

Models 120 Volt - 60Hz


Cat. No.
FTA3716 FTA7516 FTA7524

VA
37 75 75

Secondary (RMS) Volts Amps.


16.5 16 24 2.24 4.69 3.13

Secondary (RMS) N.L. Volts


19.5 17.7 26.3

Size
A B B

Weight lb.
2.2 4.0 4.0

Kg
1.0 1.8 1.8

Dimensions Size A Size B

4.625"
3.8"

2.7"

3.375"

2.7"

3.25"

Other Products, Warranty, Quality Policy


OTHER PRODUCTS Fluorescent Ballasts:
ATC-FROST manufactures a range of economical, reactor (starter type) low wattage ballasts (4-28 watt). Styles include open, enclosed and plug-in versions with a variety of mounting and termination options.

Coil Winding:
Custom winding of coils for a wide variety of applications is another service ATC-FROST provides. Solenoid coils, Air coil inductors, Proximity sensors, Electro-magnets name a few products we have supplied coils for.

Light Assembly:
ATC-FROST Magnetics would be pleased to quote on assembly work that would include our products. Examples of this might be chassis or enclosure mounting, custom terminals and connector installation, soldering, and epoxy potting. We welcome inquiries that will help you lower the installed cost of our products.

OEM Transformers
ATC-FROST Magnetics specializes in the design and manufacture of all types of inductive components for Original Equipment Manufacturers. Transformers and inductors in laminated and high frequency materials both as standard and custom are represented in our full line brochure.

WARRANTY
All of our products are thoroughly inspected and tested before leaving the factory and are guaranteed against defects in material and workmanship. All materials substituted, because of shortage of preferred materials, will be the best available. Any part proving to our satisfaction to be defective when shipped from the factory, except substitute material, and which is returned to the factory within 12 months of date of shipment therefrom, transportation prepaid, will be replaced or repaired on a gratis basis. The warranty may be voided by evidence of misuse or improper application. This warranty is limited to the REPAIR OR REPLACEMENT of the part only, and WE DO NOT ASSUME LIABILITY of any kind for the use or misuse of such equipment or the results therefrom. We assume no responsibility beyond the replacement or repair of the defective part at our factory. Changes and improvements may be made at any time in ATC-FROST MAGNETICS INC. products, but we shall be under no obligation to incorporate same in or substitute the same for any products previously delivered to any customer.

QUALITY POLICY
It is the policy of ATC-FROST Magnetics Inc. to provide its customers both product and services which meet or exceed their needs and expectations on performance, reliability, and safety, at a competitive cost.

Notes

Head Office and Plant: 1130 Eighth Line Oakville, Ontario Canada L6H 2R4 Tel: (905) 844-6681 Fax: (905) 844-6895

Waterloo Plant: 505 Conestogo Rd., Unit 12 Waterloo, Ontario Canada N2L 4C9 Tel: (519) 885-4511 Fax: (519) 885-2780

Web: www.atc-frost.com e-mail: salesatc@atc-frost.com