Factory Vision Marquee & Andon Display Users Manual Revision 3.0
Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without written permission of MacDonald Humfrey (Products) Ltd. Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
M: Emtc/Product Information/3mh-MacDonald Humfrey displays/User Guide/Factory Vision Marquee & Andon Series User Manual/Factory Vision Marquee & Andon Series Manual (Master).doc M: Emtc/Product Information/3mh-MacDonald Humfrey displays/User Guide/Factory Vision Marquee & Andon Series User Manual/Chapter 12(Converter Parts)/Chapter 12-232-485.doc M: Emtc/Product Information/3mh-MacDonald Humfrey displays/User Guide/Factory Vision Marquee & Andon Series User Manual/Chapter 13 Kepware/chapter 13-Kepware DM.doc M: Emtc/Product Information/3mh-MacDonald Humfrey displays/User Guide/Factory Vision Marquee & Andon Series User Manual/Chapter 14,15&16 Stainless Steel Display Overview & Pre-Installation/Chapter 14,15&16 Stainless Steel Overview & Install.doc
Page
4 4 4 4 4 5 5 5 5 5 6 6 6
8
9
11
13
14
16
Chapter 4M- Marquee Display Installation Chapter 1A- Andon Display Product Overview
Offloading & Handling
18 25
26
28
29
30
32
Chapter 4A- Andon Display Installation Chapter 5- Routine Maintenance Chapter 6- Troubleshooting
Schematic Drawing of Factory Vision Internal PC Marquee Board Schematic Drawing of Factory Vision Non-Internal PC Marquee Board Schematic Drawing of Factory Vision Andon Board Spare Parts List
34 41 42
42 43 44 45
51
51 53 54 55 56
57
59 60 61 61
64
64 64 65 66 67 68 70 71 73 74 74 77 79 79 80 81 81 82 85 86 87 88 88 90 90 91 95 95 97
2
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
114
114 115 115 116 116 116 117 119 121 124 130 130 135 136 140 144 149 151 153 156
Chapter 11- Computer Specifications for PC Version Appendix A, PCAnywhere Appendix B, AlphaSender II Appendix C, MHASCC Serial Communication Protocol
MHASCC Serial Communication Protocol NUM Command: Numeric Display Command TX1 Command: Text Command AW1 Command: Write Values & Attributes AC1 Commands: Activate Attributes CLR Command: Clear TIM Command: Time Command 852 Marquee Command: Alpha Numeric Marquee Command SDM Command: Page Flip Command
Appendix D, Command Examples Appendix E, ASCII Control Codes Appendix F, Glossary of Acronyms & Abbreviations Chapter 12- Communications Hookups for Non PC Version Displays
Factory Vision RS-232 to RS-485 Converter (FVKCONV232-485) Ethernet Wireless Options
Chapter 13- Connecting Kepware to Data Manager Chapter 14S- Stainless Steel Display Product Overview Offloading & Handling Chapter 15S- Stainless Steel Display Pre-Installation Set up Guide Pre-Installation Set-up Objectives Pre-Installation Check Pre-Installation Set-up Objectives for Non-PC Version Displays Chapter 16S-Stainless Steel Display Installation Installation On Board PC Gigatron Board LED Distribution Board 5V LED Power Supply
206 211 212 213 213 213 215 216 217 218 218 219 220
3
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Revision
1.0 2.0 3.0
Description of Change
Original Version Added Chapter 14, 15 & 16 Stainless Steel Displays Page 95 added Hardware Compatibility information
Scope This guide is intended for people who are responsible for installing, commissioning and maintaining the MacDonald Humfrey Full Matrix LED Marquees. Users are expected to have the required knowledge of electrical installation and communication fundamentals and, where relevant, the qualifications to install this type of equipment to meet local regulatory requirements. Overview This document is designed to provide personnel with information that will allow them to setup and program the MacDonald Humfrey Full Matrix LED Marquees. Product Update Information Product Updates can be accessed from Electro-Matic Products via the web with the following steps
Trademarks IBM PC, PS/2, PC/AT are trademarks of International Business Machines Corporation. Intel is a trademark of Intel Corporation. AWARD is a trademark of AWARD International Inc. Windows is a trademark of Microsoft Corporation. pcAnywhere is a trademark of Symantec Corporation. Factory Vision is a trademark of Electro-Matic Products Inc.
4
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Service Policy
Electro-Matic Products offers unlimited technical phone support for the Factory Display Product. A 24 Hour pager is available for access to this technical support after normal business hours. The pager number is (810) 870-1512. Additionally, one day of support at Electro-Matic Products, Inc. is included with any purchase of 5 or more displays. This support is intended for use in order to familiarize the customer with the product and aid with initial start-up. Product orientation can also be done at Electro-Matic Products prior to product shipment. PLC programming assistance and/or software integration is not included in this support offering. Additional on-site service support can be purchased for $100.00 per hour or $800.00 per day (plus travel and living expenses for areas outside of Metropolitan Detroit).
Related Publications:
Data Manager user guide on companion CD-ROM pcAnywhere user guide on companion CD-ROM Other software training manuals as appropriate.
Note:It is strongly recommended that the instructions in Chapter 2-Set Up Configuration Guide be carried out prior to installation of the Display Board.
Warranty Conditions
All work must be carried out by qualified personnel. Failure to comply with the recommendations contained in this user guide will void warranty. Faulty components should be returned to supplier for repair.
Introduction
This guide explains the safe handling procedures that must be followed when installing and servicing the VS4000 series Intelligent LED Process Display Board. If neglected, physical injury and/or death may follow, or damage may occur to the boards components. The material in this section and the introduction and installation sections (Chapters 1 & 2) must be studied before attempting any work on this unit.
Warnings
Readers are informed of situations that can result in serious physical injury and/or serious damage to equipment with the following symbols:
6
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
FALL HAZARD. This warning indicates that care should be taken when opening or closing the gas strut assisted doors. CRUSH HAZARD. This warning indicates that care should be taken when opening, closing or moving the unit, as there is a danger of physical injury.
TOPPLING HAZARD
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
TOPPLING HAZARD. This warning indicates that the unit is unstable when unsupported and may present a danger of physical injury if handled improperly.
7
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 1M, Marquee Display Product Overview
The Factory Vision Display product line is divided into two groups; Marquee and Andon. The Marquee group consist of one to four line displays housed in an extruded aluminium cabinet. Components are accessed from either end of the display. The Andon group consist of five to eight line displays housed in a steel cabinet. Components are accessed from a front or back door that lifts up with the aid of pneumatic pistons. Chapters 1M through 4M offer Marquee information, Chapters 1A through 4A offer Andon information. Chapters 5 through 10 offer information common to both display types. This pictorial gives a brief description of the major parts of the Factory Vision One to Four Line Marquee LED Display and tells you where to locate them on the unit.
8
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Offloading
CAUTION! The crated Display Board is heavy. Qualified personnel using suitable lifting equipment, straps and supports must be deployed when offloading.
Unpacking
TOPPLING HAZARD
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
The Display Board is free standing within its transportation-packing crate. The crate is secured by nails and/or screws and therefore can be dismantled by means of simple hand tools. CAUTION! Due to the narrow construction of the Display Board it is unstable when left unsupported. Care should be taken when unpacking to ensure the unit is supported at all times.
Ground Handling
CAUTION!
Hazard - Crushing The Display Board is heavy: Up to 289 pounds depending on model. Suitable lifting equipment should be used when handling the unit. Hazard - Toppling Due to the narrow construction of the unit, the Display Board is unstable when left unsupported. It is suggested that the unit should only be removed from the packing case when a suitable method of support is available, i.e. chain block and straps. DO NOT attempt to lift the display unit with a forklift truck. The base of the unit is not designed as a weight bearing structure except where the supports are fitted.
TOPPLING HAZARD
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
CAUTION!
DO NOT!
9
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
X
CAUTION!
X
This device is not intended for use at ground level. It should be suspended from the fitted eyebolts. Handle with extreme care. Safe handling recommendations are as follows; When the length of the support base equals or exceeds the unit height. When the unit is restrained by attaching slings or chains to the eyebolts and the slings or chains are fastened securely to a suitable structure.
OK
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
OK
10
Factory Vision Marquee Series Users Manual Chapter 2M Marquee Display Pre-Installation Set Up Guide
The FV Series process control boards (PCB) runs a Windows operating system. Some familiarity with the operating system being used is assumed in the set up and configuration of the display board.
Pre-installation check
1) Check documentation pack: a) Windows license b) pcAnywhere CD c) Application setup file CD 2) Set laptop or PC TCP/IP settings comparable to the displays default settings, rebooting as necessary. 3) Connect laptop or PC to RJ45 connector on top of display either directly using a crossover lead or via hub using a standard patch lead. 4) Apply power and wait for display to boot up and display template, approximately 3-4mins. Note: It is important that the network cable is connected prior to powering the display. 5) Make remote connection to display using either pcAnywhere or NetMeeting - see following table for user name and password 6) Change display PCs name as required. Note: A reboot is required for the change to be effective; this will be done later. 7) Change display TCP/IP settings as required. Refer to Chapter 8 first section. Note: On Windows2000 and WindowsXP TCP/IP address changes are effective immediately and the connection will be lost. Reconfigure your laptop/PC comparable to the displays new TCP/IP address, rebooting if necessary. Re-establish the remote connection to complete the displays network configuration. 8) Reboot the display to ensure correct configuration. (Optional) 9) Shut down windows. The display is now ready for installation.
11
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
The display unit comes supplied with several pieces of installed software. Below are the default user names and passwords. Application Default Settings User name DataManager pcAnywhere pcAnywhere NetMeeting (Desktop sharing) User User PCB Administrator level user Password Password Password PCB Administrator level user Customer settings User name Password
Windows user level, user and password are shown in the table below. Note: Passwords are case sensitive. XPE has been configured as a single user system. User level Default Settings User name Administrator Administrator Administrator vs4000 Password Windows 2000 admin vs4000 Customer settings User name Password
IMPORTANT NOTE: Proper Windows shutdown must be performed prior to any movement or shipping of display or warranty will be voided. Improper Shutdown prior to movement may damage hard drive. The display is now ready for installation.
12
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
4XXXX Go to Chapter Nine section Serial Communications Protocol for set up and programming via ethernet. 5XXXX Go to Chapter Nine section Adaptive Reduced Version Protocol for set up and programming via ethernet. 3) Wait approximately one to two minutes for display to complete power-up sequence.
13
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 3M Marquee Display External Connections
CAUTION!
Electrical Connections
The Display Board requires a 110Vac 50-60Hz supply. Note: Refer to Chapter 4M Marquee Display Installation for power requirement by model number. 110 AC Neutral 110 AC Hot
Ground
14
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Sound:
External connections to internal PC consist of a PS2 port for a mouse or keyboard (both with a splitter, a video port of a monitor and a USB port. Non-PC Marquee will have a Ethernet In and a RS-485 Serial In port: PC Version Non-PC Version
PC Reset Audio Connector
USB Port
Network Connection PS2 Port KBRD/Mouse USB Port External Monitor Network Connector
15
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Equipment
QTY 1 1 1 1 Description 100' 16 gauge 4-wire w/ shield 15W speaker 12' 22 gauge 4-wire w/shield 8A4000-31 Female straight micro connector Inventory stock stock customer supplied stock
Data
An array of tests was done to find the maximum sound level and maximum sound level without distortion. A 100 spool of 16 gauge 4-wire with shield, and a supplied with speaker 12 length of 22 gauge 4-wire with shield was tested. Each length was tested individually, and also together with a connector joining the two, to produce a length of 100 16 gauge, and 12 22 gauge equaling 112 total. Outlined on the next page is a chart demonstrating the tests and their results.
Wire GA 22 16 16+22
With Distortion Cable Length (ft) Decibel Level (dB) 5 115 100 115 100+12=112 115 Without Distortion Cable Length (ft) Decibel Level (dB) 5 108-113 100 108-113 100+12=112 108-113
Wire GA 22 16 16+22
Analysis
The data collected shows that at a distance of 100 there is no interference/noise of any kind. However, with the volume set at 100% there is a significant level of distortion, which in turn means the input is too strong for the specifications of the speaker. To minimize distortion, decrease the volume to 25% or less, depending on desired loudness.
Conclusion
The tests consisted of using different gauges of wire to determine an optimal length without experiencing interference. After completion the conclusion was made that 16 gauge would be the optimal thickness, also a length of 100 feet or greater could be used without incurring interference. The maximum size wire that can be used is 16 gauge due to the restrictions of the connectors. At this time further testing has not been done for distances greater than 112. From the data taken, conclusions can be made that 16 gauge 4-wire w/ shield can be used 100 feet or greater without experiencing interference, or power loss (dB).
17
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 4M Marquee Display Installation
Ground Handling
Before handling, testing or installing the Display Board, familiarize yourself with Chapter 1 of this manual Offloading & Handling. There are a variety of safety issues, which need to be understood and complied with to ensure the safety of you, the Display Board and other people in the vicinity.
Mechanical Installation:
The Display Board should be installed suspended from the four corner suspension points supplied with the unit. In addition to four corner suspension points there are two safety eyelets centrally located at each end of the Display. These safety eyelets are intended for use when lifting the Display unit into place, leaving the four main eyebolts free for fixing to the permanent suspension points. These safety eyelets are also used for a safety cable if required by local ordinaces. Qualified personnel should install the unit. Supporting chains must hang vertically utilising all four eyebolts. supporting chains should be fixed at both ends. Do Not Loop Chains Over Girders Etc. CAUTION! Care should be taken to ensure supporting chains are suitably rated to carry the quoted weight and are correctly secured to the unit. The support structure should be suitable to support the quoted weight of the unit. All
CAUTION!
CAUTION!
18
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
OK
19
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
20
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
21
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
On Board PC. Each Factory Vision Marquee (PC Version) has a dedicated onboard computer running a Windows operating system. These are located inside the display and are held in place by four mounting screws. The onboard PC also has an embedded music unit that provides 256 tunes to a loud speaker. The Factory Vision Marquee (Non-PC Version) does not have an imbedded PC thus the Gigatron Board gets its set-up configuration from an external PC via Ethernet or serial connection. The non-PC unit thus does not have music capabilities. Gigatron Board. Each Factory Vision Display has a Gigatron Board which acts as the video driver for the marquee. For the embedded PC display type, the video information is fed to the Gigatron board via the serial cable and video cable shown below. For the non-embedded PC display, the video information is fed to the Gigatron board via the Ethernet port, or RS232/RS484 port shown below. The video signals, now formatted for the display, are fed out of the Gigatron via the A and B side LED distribution cables.
Gigatron Board
PC Hard drive cable from PC to drive located under the Gigatron Board
PC Board
B Side video output connector from Gigatron to LED Distribution Board on B side of Display A Side video output connector from Gigatron to LED Distribution Board on A side of Display
RS232 used to feed an optional 2nd Gigatron PS2 port for Mouse and/or Keyboard Ethernet connection for PC based display Speaker output from music module PC Reset Button 12V/24V connection (Not Used) Ethernet connection for Non-PC based display 5 Volt Power connections Two USB Ports
22
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
5 Volt Power
23
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
24
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 1A- Andon Display Product Overview
The Factory Vision Display product line is divided into two groups; Marquee and Andon. The Marquee group consist of one to four line displays housed in an extruded aluminium cabinet. Components are accessed from either end of the display. The Andon group consist of five to eight line displays housed in a steel cabinet. Components are accessed from a front or back door that lifts up with the aid of pneumatic pistons. Chapters 1M through 4M offer Marquee information, Chapters 1A through 4A offer Andon information. Chapters 5 through 10 offer information common to both display types. This section of the manual gives a brief description of the major parts of the Factory Vision Five to Eight Line Andon LED Display and tells you where to locate them on the unit.
25
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Inspection
CAUTION! The Display Board should be inspected for obvious shipping damage. Do not attempt to operate the unit if any damage is found.
Offloading
CAUTION! The crated Display Board is heavy. Qualified personnel using suitable lifting equipment, straps and supports must be deployed when offloading.
Unpacking
TOPPLING HAZARD
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
The Display Board is free standing within its transportation-packing crate. The crate is secured by nails and/or screws and therefore can be dismantled by means of simple hand tools. CAUTION! Due to the narrow construction of the Display Board it is unstable when left unsupported. Care should be taken when unpacking to ensure the unit is supported at all times.
Ground Handling
CAUTION! DO NOT attempt to open the doors whilst the display is on the ground without a suitable method of support in place, i.e. chain block and straps.
Hazard - Crushing The Display Board is heavy: 110Kg 440Kg depending on model. Suitable lifting equipment should be used when handling the unit.
TOPPLING HAZARD
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
Hazard - Toppling Due to the narrow construction of the unit, the Display Board is unstable when left unsupported. It is suggested that the unit should only be removed from the packing case when a suitable method of support is available, i.e. chain block and straps. DO NOT attempt to lift the display unit with a forklift truck. The base of the unit is not designed as a weight bearing structure except where the supports are fitted.
CAUTION!
DO NOT!
26
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
X X X
CAUTION! This device is not intended for use at ground level. It should be suspended from the fitted eyebolts. Handle with extreme care. Safe handling recommendations are as follows; When the length of the support base equals or exceeds the unit height. When the unit is restrained by attaching slings or chains to the eyebolts and the slings or chains are fastened securely to a suitable structure. CAUTION! This instruction is particularly important when the doors are to be opened. Under NO circumstances should the doors be opened when the above precautions are not in place.
Min. Length = X
27
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 2A Andon Display Pre-Installation Set Up Guide
The Factory Vision Andon Series Imbedded PC runs a Windows operating system. Some familiarity with the operating system being used is assumed in the set up and configuration of the Display Board.
Pre-installation Check
1) Check Documentation Pack: a) Windows License b) Application Setup File and Manual CD 2) Apply Power to the Display 3) Wait approximately 3-4mins for display to complete boot up and display desktop Icons or display template.
The unit comes supplied with several pieces of software. With the exception of Data Manager, all passwords and user names have been set up as PCB. Unless otherwise stated in this document, I.E. Default Data Manager All Other Software Settings Applications User name: User PCB Password: Password PCB IMPORTANT NOTE: Proper Windows shutdown must be performed prior to any movement or shipping of display or warranty will be voided. Improper Shutdown prior to movement may damage hard drive. The Display is now ready for installation.
28
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
4XXXX Go to Chapter Nine section Serial Communications Protocol for set up and programming via ethernet. 5XXXX Go to Chapter Nine section Adaptive Reduced Version Protocol for set up and programming via ethernet. 3) Wait approximately one to two minutes for display to complete power-up sequence.
29
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 3A Andon Display External Connections
Power Electrical Installation:
The Protective Conductor (Earth Wire) must be connected for safety reasons. Check that the power cable has a proper Earth Wire, and it is properly connected. It is not safe to operate the Display Board without the Protective Conductor connected. CAUTION! Do not exceed the voltage rating on the label located on the top of the power supply cowling. Do not work on the unit unless the power is disconnected.
CAUTION!
Electrical Connections
The Display Board requires a 110Vac 50-60Hz supply. Note: Refer to Chapter 4A Andon Display Installation for power requirements by model number.
The AC Power Connection is located next to the left hanger bolts: Note: L1 power must be supplied to both pin 1 and 4 and wire sized with not more than 15 amps total current on each wire. The same holds true for L2 (pins 2 and 5).
30
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Sound:
External connections to internal PC consist of a PS2 port for a mouse or keyboard (both with a splitter, a video port of a monitor and a USB port.
31
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Music Decibel Level and Remote Speaker Distances
Introduction
The purpose of this report is to test the audio performance of the MacDonald Humfrey soundboard. In detail, this report will describe the analysis and data taken in regards to sound intensity and decibel level.
Equipment
QTY 1 1 1 1 Description 100' 16 gauge 4-wire w/ shield 15W speaker 12' 22 gauge 4-wire w/shield 8A4000-31 Female straight micro connector Inventory stock stock customer supplied stock
Data
An array of tests was done to find the maximum sound level and maximum sound level without distortion. A 100 spool of 16 gauge 4-wire with shield, and a supplied with speaker 12 length of 22 gauge 4-wire with shield was tested. Each length was tested individually, and also together with a connector joining the two, to produce a length of 100 16 gauge, and 12 22 gauge equaling 112 total. Outlined on the next page is a chart demonstrating the tests and their results.
32
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Wire GA 22 16 16+22
With Distortion Cable Length (ft) Decibel Level (dB) 5 115 100 115 100+12=112 115 Without Distortion Cable Length (ft) Decibel Level (dB) 5 108-113 100 108-113 100+12=112 108-113
Wire GA 22 16 16+22
Analysis
The data collected shows that at a distance of 100 there is no interference/noise of any kind. However, with the volume set at 100% there is a significant level of distortion, which in turn means the input is too strong for the specifications of the speaker. To minimize distortion, decrease the volume to 25% or less, depending on desired loudness.
Conclusion
The tests consisted of using different gauges of wire to determine an optimal length without experiencing interference. After completion the conclusion was made that 16 gauge would be the optimal thickness, also a length of 100 feet or greater could be used without incurring interference. The maximum size wire that can be used is 16 gauge due to the restrictions of the connectors. At this time further testing has not been done for distances greater than 112. From the data taken, conclusions can be made that 16 gauge 4-wire w/ shield can be used 100 feet or greater without experiencing interference, or power loss (dB).
33
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 4A Andon Display Installation
Ground Handling
Before handling, testing or installing the Display Board, familiarize yourself with Chapter 1 of this manual Offloading & Handling. There are a variety of safety issues, which need to be understood and complied with to ensure the safety of you, the Display Board and other people in the vicinity.
Mechanical Installation:
The Display Board should be installed suspended from the four corner suspension points supplied with the unit. In addition to four corner suspension points there are two safety eyebolts centrally located at each end of the Display. These safety eyebolts are intended for use when lifting the Display unit into place, leaving the four main eyebolts free for fixing to the permanent suspension points. They are also to be used for a safety cable if required by local ordinances. Qualified personnel should install the unit. Supporting chains must hang vertically utilising all four eyebolts. supporting chains should be fixed at both ends. Do Not Loop Chains Over Girders Etc. CAUTION! Care should be taken to ensure supporting chains are suitably rated to carry the quoted weight and are correctly secured to the unit. The support structure should be suitable to support the quoted weight of the unit. All
CAUTION!
CAUTION!
34
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
X
35
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
36
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
37
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Gigatron Board
PC Board
B Side video output connector from Gigatron to LED Distribution Board on B side of Display A Side video output connector from Gigatron to LED Distribution Board on A side of Display
RS232 used to feed an optional 2nd Gigatron PS2 port for Mouse and/or Keyboard Ethernet connection for PC based display Speaker output from music module PC Reset Button 12V/24V connection (Not Used) Ethernet connection for Non-PC based display 5 Volt Power connections Two USB Ports
38
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
5 Volt Power
39
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
40
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 5 Routine Maintenance Vent Filters
The Display has several ventilation ports fitted with dust filters. The filters are of the clip on type and may be removed by hand without tools. Depending on the prevailing environmental conditions the filters will become clogged after a period of use. Routine maintenance and cleaning entails the removal and cleaning or replacement of these four filters.
General Cleaning
The protective covers to the doors on the display are made of polycarbonate; While physically tough and coated with an anti-glare and scratch resistant coating, polycarbonate is susceptible to chemical attack. Therefore only mild detergents and water should be used in the cleaning of the screen. A periodic wipe over with a damp cloth should be sufficient to keep the display clear and clean.
Vent
41
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
42
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
43
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
44
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
46
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Chapter 6 Troubleshooting
Blank Display
Symptoms No images to either side of display Possible Causes AC Power Missing 5 VDC Power Failure User Application Software Not Running Correctly Screen Saver Setting Display Position Coordinates incorrectly set Corrective Action Check Fuses/Breakers Restore Power Replace Power Supply Run User Application Software Disable Windows Screen Saver Set Display Position Coordinates to correct settings (refer to chapter 10, LED Panel set)
47
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
AC Power Missing
Frozen Display
Symptoms Display is not updating any incoming Data. Possible Causes Driver not running Communication cable disconnected Original board configuration modified Corrective Action Start driver and make sure is in startup menu Reconnect cable Restore board configuration to original working state
48
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
49
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Video Signaling Ribbon Cable connection To Displays error Ribbon cable damaged Ribbon cable damaged Display size set improperly
Connect Video Signaling Ribbon cables from driver board to LED board in proper sequence Replace ribbon cable between Gigatron and LED board Replace ribbon cable between LED board and 1st LED segment Use LED Main Menu program to setup proper display size in Gigatron Filter incoming connections
50
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
7/16 Screws
The back side of the Factory Vision Marquee is identified by the AC power port residing on the right end of the marquee cabinet. To access the components residing on the back panel (Back LED segment boards, Back LED Segment Board Power Supplies, and Back LED Distribution Board) remove the four screws holding the access panel that has the AC Power Port:
51
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
7/16 Screws
To remove the front or back display board, remove the appropriate access panel (see above) and pull out the display board. Note: To get a better grip on the board you may want to use a piece of wire or rope looped around one of the display stand-offs as shown below. Note: Be careful to ensure that wires from the opposite display board are clear of the board that is being removed.
52
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
B Side video output connector from Gigatron to LED Distribution Board on B side of Display A Side video output connector from Gigatron to LED Distribution Board on A side of Display
RS232 used to feed an optional 2nd Gigatron PS2 port for Mouse and/or Keyboard Ethernet connection for PC based display Speaker output from music module
53
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
5V DC Power Supply
Mounting Screws
54
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
5 Volt Power
Mounting Screws
55
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Mounting Screws 56
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 7A Andon Display Component Replacement
Display Board Removal Procedure
The front side of the Factory Vision Andon is identified by the Power Switch residing on the Left end of the Andon cabinet. To access the components residing on the front panel (Front LED segment boards, Front LED Segment Board Power Supplies, PC, Gigatron, and Front LED Distribution Board) twist the Two thumb screws at the bottom of the display and raise the cabinet door:
CAUTION!
The cabinet door lifts with the aid of pneumatic pistons. Allow enough space between you and the door when opening to prevent the door from knocking you off your lift or ladder!
Thumb Screws
57
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Once the door is open, you will have access to all components for front and back display.
The following illustration show the location of major components within the Andon Display Board:
PC and Gigatron
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
LED Distribution
LED Segments 58
59
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
5V DC Power Supply
Mounting Screws 60
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
5 Volt Power
Mounting Screws
61
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
62
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
63
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 8 How to Access Display Remote Display Connection Setup Setting up the IP Address for connection to the full matrix display: This will allow the user to establish a remote connection from a PC to the display board. The following setup procedures cover configuring your PC network settings for Window 98, NT and 2000 or XP: If your computer is running Windows 98: For Windows 98, click on the start menu
Select the Configuration tab and click on TCP/IP (Brand Name of Ethernet Card) Card and then select properties. In the properties menu you will see an IP tab, click on that tab and you will see this:
Click on Specify an IP address and enter an IP address that is similar to the one on the display. The default address of the display is 192.168.0.250. The address that you enter in your computer must match the first three numbers of the display IP address. For example, you could enter 192.168.0.200 into your computer. This contains the same first three numbers 192.168.0 as the display. The last number can be any number up to 250 except the number that is contained on the display. In this case that number is 250. The default subnet mask is always 255.255.255.0. This should be the same as the display. When finished setting up the new IP address click OK and restart the computer for the new IP address to take effect.
64
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual If your computer is running Windows NT: For Windows 98, click on the start menu
Select the Protocols tab and click on TCP/IP Protocol and then select properties. In the properties menu you will see an IP Address tab, click on that tab and you will see this:
Click on Specify an IP address and enter an IP address that is similar to the one on the display. The default address of the display is 192.168.0.250. The address that you enter in your computer must match the first three numbers of the display IP address. For example, you could enter 192.168.0.200 into your computer. This contains the same first three numbers 192.168.0 as the display. The last number can be any number up to 250 except the number that is contained on the display. In this case that number is 250. The default subnet mask is always 255.255.255.0. This should be the same as the display. When finished setting up the new IP address click OK and restart the computer for the new IP address to take effect.
65
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual If your computer is running Windows 2000 or XP: The signs run Windows XP so once remotely connected use this procedure to change the IP address. For Windows 2000 or XP, click on the start menu
Click on the Properties button on the Local Area Connection Status window:
Click on Use the following IP address and enter an IP address that is similar to the one on the display. The default address of the display is 192.168.0.250. The address that you enter in your computer must match the first three numbers of the display IP address. For example, you could enter 192.168.0.200 into your computer. This contains the same first three numbers 192.168.0 as the display. The last number can be any number up to 250 except the number that is contained on the display. In this case that number is 250. The default subnet mask is always 255.255.255.0. This should be the same as the display. When you are finished setting up the new IP address click OK and the new IP address will take effect. 66
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Connecting to Display using VNC
VNC is used for remote viewing of the internal PC in the full matrix display from a remote computer. To use VNC you must first install the VNC Software on your computer. Electro-Matic Products can provide a copy or it can be found at www.realvnc.com. Click on VNC icon:
Now you have control of the display PC. Click the X in the upper corner to close the connection.
67
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Connecting to Display using NetMeeting
Click on NetMeeting icon:
Click on the Security Tab and check the box for I prefer to make secure outgoing calls and click OK:
68
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Now you have control of the display PC. Click the Hang up icon on the original connection window to close the connection.
69
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Viewing Display using Internet Explorer on a Remote PC: Using Internet Explorer, enter in either the IP address or the computer name of the display board. The computer (display board) name will start with a FV and contain a number such as 1330 (FV1330). For Example:
This will open a viewer on the Internet Explorer that will display both sides of the display board. This viewer will update every 10 seconds. This is how the display will look on your computer:
70
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Data Manager Introduction: The Data Manager HMI software is used to create the templates on the display boards. These templates consist of display fields that are linked to either the data collection system or to Allen Bradley PLCs via DDE links to Ethernet/DDE driver programs. The Data Manager program runs on the display boards internal PC thus the DM program must be accessed directly through the monitor; keyboard and mouse ports on the display board or via a remote PC on the Ethernet network using PC Anywhere, NetMeeting or VNC. To use Data Manager, double-click on the DM Icon on the desktop: Note: Data Manager can be set to start automatically on the display board by placing the DM.exe in the Windows Startup directory along with the startup of the necessary TCP/IP DDE drivers.
The Data Manager should be configured to start up with a default screen in RUN mode. Fields on the screen will start displaying live data sent by either the data collection system or Allen Bradley PLCs. Otherwise the running screen will display the default characters while waiting for data:
To make any changes to the Data Manager Project, you must first Log In:
The default login name is user The default password for user is password
71
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Once you are logged in, the configuration menu can be opened by selecting File/Configure:
In configuration mode, several tool tables should be visible such as: Tool Box which contains drawing items. Layer Control which allows you to create and specify different drawing layers Object Background which allows you to change object colors Data Manager Logger which allows you to create and edit Tags.
72
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Setting Up a New Template on Data Manager
Select File and New to start a new page.
Select Drawing Background in the color palette and select black for the background. The color black is recommended when using the Data Manager Software on a full matrix display.
Select the line in the toolbox to draw the border of the display. This border is used to set up a template so that this newly created template will fit exactly in the viewing area of the full matrix display. In this example we will use a display that is 200 X 100 pixels.
The outline of the template is usually a small area on a normal laptop or PC. To make this area larger the user can go to the view menu and click on zoom in. This can be done a number of times to make editing of the screen easier.
73
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Data Manager Application Settings: The following Application Setup menu allows you to configure the default screen name, the Startup in Run Mode configuration and the Maximum Undo Limit:
Data Manager Text Types, Tags and Dynamic Data Exchange (DDE): There are two types of text that can be added to a display screen, the first type is called Static Text which is text that does not change through animation depending on the value of a tag. The following tool button is used to create static text:
The following menu is used to enter the static text and establish horizontal and vertical justification:
74
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The second type of text is Dynamic Text that is designed to show the value of an internal (dummy), Real (tied to a port) or DDE type tag. The following button is used to create dynamic text:
The following menu comes up after selecting the location on the screen for the new dynamic text. This menu is used to select the tag that will animate the text. Note: the tag must already exist for this menu to be used.
Use the Select Tag button to select the tag from the tag list: Note: All tags will be entered into this menu as Tagname.Current Value:
75
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
A list of current tags belonging to this project will be displayed in the following table. To view and edit the tag attributes, double-click on the tag in the tag list:
76
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Data Manager Tag Definition: The Tag Definition menu is used to create a tag name, define the tag as a dummy (or internal) tag , a Real (or port connected) tag or a DDE tag. We will be using DDE type tags to communicate with the MHASCC or MHAAB TCP/IP DDE servers. The DDE Tag format is = Server|Topic!Item Where: Server is the source program that feeds the tag, in our case MHASCC or MHAAB. Topic is a category within the server dedicated to a certain data type, Topic names can be any name, in our case for the current project, MHASCC|A1PROJ, A1ACTUAL, A1CELLS, A1MARQUEE or MHAAB|BLOCK1. A1 stand for side 1 of the display; if the display has a second side, different information can be sent to topics starting with A2.... Item is the specific source point for the data, Item names must match available commands in protocol communicating with the tag. Current Items recognized by the MHASCC driver are: NUM, R01C01T..., R01C01C... and MARQUEE. Items recognized by the Allen Bradley PLC from the MHAAB Server are: R1 through R32. Since the screen in this example has two rows of eight cells being feed by the MHAAB Server, R1 through R16 are used. If different information is to be displayed on the back side of a two sided sign, R17 through R32 can be used. Note: The server name must be proceeded with an equal = sign, The topic name must be proceeded with a pipe | sign, The item name must be proceeded with a bang ! sign. Note: A Data Manager project can have multiple DDE source programs in which each can have multiple topics in which each can have multiple items. Note: By design DataManager will periodically to attempt to establish a DDE connection for all defined DDE tags. Ensure all defined DDE tags have active data sources; failure to do so will cause DataManager, periodically, to attempt to establish a DDE connection for the tag with an unobtainable data source. This will adversely affect redrawing of the template. Any DDE tags inherited from a previous taglist, or project, may be either converted to a dummy tag or deleted. Tags may be converted between different types by editing their properties. Tags that are deleted are merely disabled and may be undeleted.
77
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The following table shows the tags used for each of the data fields on the following display:
Display Header NUM data Andon data line 1 Andon data line 2 Andon data line 3 Andon data line 4 Marquee
Note: This table is under construction. Consult your sales person for the latest version.
GOAL = MHASCC|A1PROJ!NUM ACTUAL = MHASCC|A1ACTUAL!NUM TIME = MHASCC|SYSTEM!TIME R01C01T &C R01C02T &C R01C03T &C R01C04T &C R01C05T &C R01C06T &C R01C07T &C R01C08T &C =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! R01C01T & R01C02T & R01C03T & R01C04T & R01C05T & R01C06T & R01C07T & R01C08T & R01C01C R01C02C R01C03C R01C04C R01C05C R01C06C R01C07C R01C08C R02C01C R02C02C R02C03C R02C04C R02C05C R02C06C R02C07C R02C08C =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! R1 R2 R3 R4 R5 R6 R7 R8 R03C01T &C R03C02T &C R03C03T &C R03C04T &C R03C05T &C R03C06T &C R03C07T &C R03C08T &C =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| =MHASCC| A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! A1CELLS! R03C01T & R03C02T & R03C03T & R03C04T & R03C05T & R03C06T & R03C07T & R03C08T & R03C01C R03C02C R03C03C R03C04C R03C05C R03C06C R03C07C R03C08C R04C01C R04C02C R04C03C R04C04C R04C05C R04C06C R04C07C R04C08C =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| =MHAAB| BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! BLOCK1! R9 R10 R11 R12 R13 R14 R15 R16
MARQUEE =MHASCC|A1MARQUEE!MARQUEE
78
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Defining the Goal Data Field using the MHASCC Server: The Goal display is a 4 digit decimal data field tied to the DDE Tag GOAL:
The Tag GOAL has the DDE link =MHASCC|A1PROJ!NUM Since this field will be displayed in a numeric value, the data type must be an ASCII Decimal:
The MHASCC Server program (which must be running for data to reach the Data Manager in Run Mode) is responsible for routing TCP/IP ITEMS from the data collection system (or the Alpha-Sender II program) into the proper topic folder and converting the data from TCP/IP format to DDE format for the Data Manager.
Defining a Topic using the MHASCC Server: To start the MHASCC Server, click on the desktop icon:
To view and edit a topic, Open the MHASCC Server window and select Configure/Topic Definition: Select the topic used by Goal; A1PROJ and select the Modify button:
79
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Notice that the Topic A1PROJ has a Group # of 1 and a Unit # of 4.
Note: The topic configurations are stored in a file in the C:\DM directory called Topic.csv and can be vied with Excel or Notepad. Defining the NUM Numeric Display Control Command using the MHASCC Server: The following is an example of the ASCII data string format which is sent to the MHASSC server via Ethernet. The Goal display is controlled with the NUM (Numeric Display Control Command): 021 | 000200 | <&H02>0104<&H1B>NUM-888N1A<&H04> Program line 21 send this command line for 200 milliseconds, STX <&H02>, Group 01, Unit 04, ESC <&H1B>, NUM (Numeric Display Control Command), display data -888, N = number and terminates the display field, 1 = display data On [default] (0 = Off, 2 = slow flash, 3 = fast flash), A = Attribute which terminates the field, CMD hex 04 (EOT) End of Transmission Note: The Group and Unit number rout the command to the proper MHASCC Topic and the data type NUM matches the Item name in the DDE Tag, Goal Note: The NUM data type is limited to the color selected on the Data Manger screen.
80
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Defining the Actual Data Field in Data Manager using the MHASCC Server: The Actual data field is identical to the Goal data field (see previous example) except:
The Tag Definition is Actual = MHASCC|A1ACTUAL!NUM A1ACTUAL in MHASCC Server Topic Definition has a Group # of 1 and a Unit # of 1. The following is an example of the ASCII data string format which is sent to the MHASSC server via Ethernet. The Actual display controlled with the NUM (Numeric Display Control Command)
020 | 000200 | <&H02>0101<&H1B>NUM-888N1A<&H04> Program line 20 send this command line for 200 milliseconds, STX <&H02>, Group 01, Unit 01, ESC <&H1B>, NUM (Numeric Display Control Command), display data -888, N = number and terminates the display field, 1 =display data On [default] (0 = Off, 2 = slow flash, 3 = fast flash), A = Attribute which terminates the field, CMD hex 04 (EOT) End of Transmission Note: The Group and Unit number rout the command to the proper MHASCC Topic and the data type NUM matches the Item name in the DDE Tag, Actual Note: The NUM data type is limited to color Red. Defining the Time Data Field using the Data Manager Program: The Time Data Field is provided by a Tag defined in the data manager which displays the Window clock value in a 12 or 24 hour format: The Tag Definition is Time = MHASCC|SYSTEM!TIME This Tag data type must be an ASCII String:
The Time display is a 4 digit decimal data field tied to the DDE Tag GOAL:
81
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Defining the Andon Data Cells in Data Manager using the MHASCC Server:
The Andon Cells are 3 digit ASCII string data fields (default ???) that occupy eight columns on lines One and Three of the Andon data area of the display. Each of these data cells are controlled by two tags, one for text value (R01C01T through R03C08T) and one for text color (R01C01C through R03C08C). The following images describe how to configure each Andon cell: Double-click on a Andon data cell. (in this example: row 1, column 1):
82
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual To link the text value tag to the data cell, Select R01C01T text tag:
To link the text color tag to the data cell, Select Dynamic button:
Select Select Tag button and select tag R01C01C color tag. Also ensure the following colors for the following values: Black (Off) = 0 Yellow = 5 Red = 1 Light Green = 6 Amber = 2 Brown = 7 Green = 3 Orange = 8 Light Red = 4
The Tag R01C01T has the DDE link =MHASCC|A1CELLS!R01C01T The data type must be an ASCII String since ASCII characters are to by displayed:
The Tag R01C01C has the DDE link =MHASCC|A1CELLS!R01C01C The data type must be an ASCII Decimal since a numeric value from 0 to 4 will determine the color of the displayed characters:
83
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual To view and edit the A1CELLS topic, Open the MHASCC server window and select Configure/Topic Definition:
Notice that the Topic A1CELLS has a Group # of 1 and a Unit # of 32 decimal.
Note: When creating an object that will have dynamic properties, the object MUST first be created and then subsequently selected to configure its dynamic properties. Attempting to configure dynamic properties during object creation will cause DataManager to crash.
84
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The MHASCC Protocol AC1 Cell Control Command: The following is an example of the ASCII data string format which is sent to the MHASSC server via Ethernet for the first Andon data cell (row 1 column 1). Note: This command line sends both text value data to R01C01T and text color data to R01C01C. 005 | 000200 | <&H02>0120<&H1B>AC11R1C3P1A<&H04> Program line 5, send this command line for 200 milliseconds, STX <&H02>, Group 01, Unit 20 hex = 32 decimal, ESC <&H1B>, AC1 Andon Cell Control Read CMD, 1R = Row 1, 1C = Column 1, 3P = Green text, 1A = Text On, CMD hex 04 (EOT) End of Transmission. Note: The entire command line is sent to the MHASCC server and the program waits for the specified time (200mS) before sending the next command. The Group and Unit number rout the command to the proper MHASCC Topic, the AC1 command specifies read Andon data to server, 1R1C sends text value data to R01C01T tag, 3P send the text color value 3 to R01C01C tag, 1A turns text On.
Primary Color choices are:
0P for Text Color Black or Off 1P for Text Color Red -default 2P for Text Color Amber 3P for Text Color Green 4P for Text Color Light Red 5P for Text Color Yellow 6P for Text Color Light Green 7P for Text Color Brown 8P for Text Color Orange
Note: The Slow and Fast flash rates are configured in the MHASCC server under Configuration/Flash Rate menu:
Note: The actual text value that is sent to R01C01T is contained in Bin 1 by default in a file called R01C01T.csv. Each Andon cell has a CSV file located in the DM directory on the display boards internal computer. Each CSV file has 16 lines (called Bins) for a three digit ASCII character string to be stored. By default, the AC1 command will display the contents of Bin 1; other Bin contents can be displayed by adding #B to the end of the AC1 command line where # = 1 through 16; example: AC11R1C11B will display the contents of Bin 11 in R01C01T.csv. The following example shows Bin 1 in R01C01T.csv has a value 10A, the rest of the bins are empty:
85
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Data can be entered directly into the CSV file with the use of a text editor, or it can be entered with the AlphaSender II program with the use of the AW1 command. Since the entire command is sent to the MHASCC Server via Ethernet, it is the MHASCC Server that manages the Bins within the CSV files. Each Bin position contains the following data: Bin #, Stored Text, Text Attribute, Primary Color, Secondary Color. Bins have the following defaults: Example: Bin 2 = 2,002,1,1,0: (2 = Bin 2) ( 002 = text) (1 = Text Attribute, Text On) (1 = Primary Color, Red) (Secondary Color, Black/off) The MHASCC Protocol AW1 Andon Write Command: The AW1 command is used to write data into a Bin location in the CSV file assigned to specified Andon Cell location. The following AW1 command will write 10A into Bin 1 of R01C01T.CSV: 001 | 000200 | <&H02>0120<&H1B>AW11R1C1B[10A]<&H04> Program line 1, send this command line for 200 milliseconds, STX <&H02>, Group 01, Unit 20 hex = 32 decimal, ESC <&H1B>, AW1 Andon Write CMD, 1R = Row 1, 1C = Column 1 = R01C01T.csv file, 1B = Bin 1, [10A] = data to be written to bin location, CMD hex 04 (EOT) End of Transmission.
86
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Note: The Group 01 and Unit 20 (32 decimal) number routs the command to the proper MHASCC Topic (A1CELLS), the AW1 command specifies writes 10A to Bin 1 of R01C01T.csv. The following text attributes can also be written into a bin by adding the following codes to the AW1 data area:
Primary Color choices are:
0P for Text Color Black or Off 1P for Text Color Red -default 2P for Text Color Amber 3P for Text Color Green 4P for Text Color Light Red 5P for Text Color Yellow 6P for Text Color Light Green 7P for Text Color Brown 8P for Text Color Orange
As noted above, if text attributes are not sent with the AW1 command, the following defaults are used: A (Attribute): 1 (On) P (Primary): 1 (Red) S (Secondary): 0 (Black) B (Bin): 1 Note: The AW1 and AC1 commands are sent from the data collection Server to the MHASCC Server running on the internal display PC via Ethernet. The AW1 command writes a one, two or three digit ASCII character strings to a bin location in the CSV file assigned to a specific Andon Cell. The AC1 command reads a bin location from the CSV file assigned to a specific Andon Cell and passes it to the MHASCC server which converts the data into DDE format and passes it to the Data Manager which displays it. The MHASCC Protocol SDM Page Flip Command: The SDM command is used to flip between pages on the Data Manger screen. The following SDM command will flip from page 1 to page 2 and back to page 1: 001 | 000200 | <&H02>5A01<&H1B>SDM1M<&H04> 002 | 000200 | <&H02>5A01<&H1B>SDM2M<&H04> 003 | 000200 | <&H02>5A01<&H1B>SDM1M<&H04> Program line 1, send this command line for 200 milliseconds, STX <&H02>, Group 90(5A in hex), Unit 01, ESC <&H1B>, SDM, page number = 1, M = terminates the SDM command, CMD hex 04 (EOT) End of Transmission. Program line 2 & 3 only differ by the page number to display. Note: The Group 5A and Unit 01 number routs the command to the proper MHASCC Topic (A1SCREENNO), the SDM command specifies the page number of the Data Manager project to display. To use this command make sure to set up a tag named A1SCREENNO that has the DDE link: =MHASCC|A1SCREENNO!SDM
87
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The MHASCC Protocol Time (TIM) Command: The TIM command is used to control and adjust the time and date on the Data Manager screen. The following TIM command will update the time and date on the display: 001 <Hex02>gguu<Hex1B>TIM15:45:09T2003-06-05D2A<Hex04> Program line 1 STX <Hex 02> = Start of Text gg = Group Number, must be a 2-digit numeric number (a 00 means all groups will respond) uu = Unit Number, must be a 2-digit numeric number (a 00 means all units will respond) ESC <Hex1B> = ASCII escape control code TIM = the character string (short for time) 15:45:09 = Time must be entered in 24 Hour format, but can be displayed in 12 or 24 Hour T = terminates the TIM field 2003-06-05 = Year-Month-Date, A hyphen is used to separate each field D = terminates the Date field 2 = the display format (1=12 hour, 2 = 24 hour) A = terminates the Attribute field CMD <Hex 04> = (EOT) End of Transmission The T, D and A fields are all optional. This means that any one of these fields does not have to be present. If they are not present then the value will not be changed in the system. To use this command make sure to set up a tag in the Data Manager program named TIME that has the DDE link to the MHASCC driver: =MHASCC|SYSTEM!TIME *Page 50-51 has more information on inserting the Time Tag in Data Manager The Marquee Display: The Marquee Display is designed to display text string messages on the display. These messages are limited to the color selected on the Data Manager. The tag assigned to display the message is called MARQUEE:
88
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The Tag MARQUEE has the DDE link =MHASCC|A1MARQUEE!MARQUEE The data type must be an ASCII String since ASCII characters are to be displayed:
The Topic definition in the MHASCC Server is A1MARQUEE with a Group number 01 and a Unit number of 48 decimal:
The Marquee display is designed to utilize a MHASCC configuration called Marquee that allows you to set the maximum width of the marquee display and how fast the marquee the data, which extends beyond the maximum length, will scroll, in milliseconds:
Checking the Roll Once box, will allow each message to only roll once and will not repeat.
89
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The MHASCC Protocol Marquee Command and the Checksum Command: The following POS command will send the text message START to the Marquee display field for 5 seconds: 000 | 005000 | <&H02>0130<&H0C>START<&H05><&H03>9a Program line 0, send this command line for 5 seconds, STX <&H02>, Group 01, Unit 30 hex = 48 decimal which is Topic A1MARQUEE, CMD hex 0C Form Feed, Display Text Start, CMD hex 05 (ENQ) Enquiry, , CMD hex 03 (ETX) End of text, 9a = Checksum The Checksum byte is required as the last code on the first command string of the ASCII string if an ACK or NAK is requested by the ENQ command. The ETX command says that a Checksum byte will follow. Checksum is calculated by summing all code as hex from the group number, on, dropping all but the least significant byte from the result and performing a twos compliment on the result. 9a checksum is the result of the following calculation: (30+31+33+30+0C+53+54+41+52+54+05+03=266, twos compliment on least significant byte: 100 - 66 = 9a) Note: Subtracting result from 100 performs twos compliment. Note: 30, 31, 33, 30 are the hex equivalent for ASCII 0130; 53, 54, 41, 52, 54 are the hex equivalent for ASCII START. Additional Configuration Settings in the MHASCC Server: The port number must match the port number of the data source PC:
The Client Address is used to enter the IP address of the PC that will be receiving the DDE data from the server (if server does not reside on the same computer as Data Manager):
90
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Allen Bradley PLC Communications with Andon Cells via MHAAB Server: In our example screen, eight columns of rows two and four of the Andon display area have been reserved for the display of station condition messages. These Andon Cells will display up to sixteen, three character station condition messages controlled by up to four Allen Bradley PLCs. The Andon cell tag names follow the same naming convention as the POS cells, that is the first cell on row two is R02C01C:
Unlike the Andon cells on rows one and three, the AB Andon cells do not address a text tag such as R02C01T; only the color tag (R02C01C) is used. The text comes from a file called Ledtext.ias located in the project folder for this project (C:\DM\Projects\DemoAB\Ledtext.ias). By selecting the Interpret as String check box in the Data Manager Tag Setup window, and specifying the above IAS file, the value of the tag (in our example R02C01C) determines which line of text from the Ledtext.ias will be displayed- in the Andon cell:
The Ledtext.ias file contains the following three character station condition messages:
91
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The following list defines the three character station condition message abbreviations: 0 = Blank = No Message 1 = FLT = Station Fault 2 = STP = Control Side Emergency Stop 3 = MNT = Control Side Maintenance Call 4 = LDR = Control Side Leader Call 5 = LSC = Control Side Light Screen Fault 6 = Spare 7 = TIP = Control Side TIP Change 8 = BLK = Station Blocked 9 = STV = Station Starved 10 = OVR = Station Over Cycle 11 = MNL = Control Side Manual 12 = HLD = Control Side Robot (s) in Hold 13 = MI = Control Side Manual Intervention 14 = SG = Control Side Safety Gate Open 15 = AUT = Station in Auto 16 = Spare 17 = Spare 18 = STP = Remote Station Emergency Stop 19 = MNT = Remote Station Maintenance Call 20 = LDR = Remote Station Leader Call 21 = LCS = Remote Light Screen Fault 22 = Spare 23 = TIP = Remote Station Tip Change 24 = Spare 25 = Spare 26 = Spare 27 = MNL = Remote Station Manual 28 = HLD = Remote Station Robot (s) in Hold 29 = MI = Remote Station Manual Intervention 30 = SG = Remote Station Safety Gate Open 31 = Spare 32 = REJ = Perceptron Reject Part 33 = PTW = Perceptron Trend Warning 34 = Spare 35 = Spare 36 = TRQ = Nut Runner Torque Fault 37 = Spare 38 = Spare 39 = Spare 40 = Spare 41 = Spare 42 = Spare 43 = Spare 44 = Spare
92
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual 45 = Spare 46 = Spare 47 = HPR = Hopper Low 48 = Spare 49 = Spare 50 = Spare 51 = Spare 52 = TRQ = Nut Runner Torque Fault 53 = Spare 54 = Spare 55 = Spare 56 = Spare 57 = Spare 58 = Spare 59 = Spare 60 = Spare 61 = Spare 62 = Spare 63 = HPR = Remote Hopper Low The color and flash properties of the text message is also controlled by the color tag (R02C01C). To view/edit the text color, select the Dynamic button on the Tag Setup Screen: Select the Line/Text button:
Ensure that the proper color tag for the selected Andon cell is entered and verify the following color/flash properties for the following values: Note: since the same tag determines both the text and the color/flash property, the color/flash property will remain constant for each text message:
Factory Vision Marquee Series Users Manual 2 = Red = STP = Control Side Emergency Stop 3 = Yellow Flash = MNT = Control Side Maintenance Call 4 = Green Flash = LDR = Control Side Leader Call 5 = Yellow = LSC = Control Side Light Screen Fault 7 = Yellow Flash = TIP = Control Side TIP Change 8 = Green = BLK = Station Blocked 9 = Yellow = STV = Station Starved 10 = Red Flash = OVR = Station Over Cycle 11 = Yellow = MNL = Control Side Manual 12 = Red = HLD = Control Side Robot (s) in Hold 13 = Yellow = MI = Control Side Manual Intervention 14 = Red = SG = Control Side Safety Gate Open 15 = Green Flash = AUT = Station in Auto 18 = Red = STP = Remote Station Emergency Stop 19 = Yellow Flash = MNT = Remote Station Maintenance Call 20 = Green Flash = LDR = Remote Station Leader Call 21 = Yellow = LCS = Remote Light Screen Fault 23 = Yellow Flash = TIP = Remote Station Tip Change 27 = Yellow = MNL = Remote Station Manual 28 = Red = HLD = Remote Station Robot (s) in Hold 29 = Yellow = MI = Remote Station Manual Intervention 30 = Red = SG = Remote Station Safety Gate Open 32 = Yellow Flash = REJ = Perceptron Reject Part 33 = Green Flash = PTW = Perceptron Trend Warning 36 = Red = TRQ = Nut Runner Torque Fault 47 = Yellow Flash = HPR = Hopper Low 52 = Red = TRQ = Nut Runner Torque Fault 63 = Yellow Flash = HPR = Remote Hopper Low Note: The color Black is the same as off and will show nothing in the area designated.
ControlLogix processors with 1756-ENET or 1756-ENBT module CompactLogix processors with Ethernet module PLC5 'E' Series PLC5 Enhanced Processors with 1785-ENET module SLC5/05 SoftLogix5 SLC5/03, SLC5/04 via 1761-NET-ENI module PLC5 via 1761-NET-ENI module MicroLogix 1000/1200/1500 via 1761-NET-ENI module PLC5 via ControlLogix Gateway to DH+
SLC5/04 via ControlLogix Gateway to DH+ ControlLogix via ControlLogix Gateway to DH+
Supported PLCs The following PLC's are supported. This list may change as processors are added, but all processors within a family (PLC5, SLC500, Logix) should be compatible. PLC5/20E PLC5/40E PLC5/80E PLC5 enhanced processors with 1785-ENET (Ethernet Side Car) SLC5/05 ControlLogix 5550 with 1756-ENET module SoftLogix5 SLC500 via channel 0 with 1761-NET-ENI Module MicroLogix 1000/1200/1500 via channel 0 with 1761-NET-ENI Module PLC5 processors via channel 0 with 1761-NET-ENI Module The MHAAB Topic Server contains one topic call: BLOCK1. The topic (BLOCK1) contains sixteen items: R1 through R16 (can be up to R32); Each item is assigned to an Andon display cell that represents the condition of a station. So Row 2 is assigned BLOCK1!R1 through R8 and Row 4 is assigned BLOCK1!R9 through R16 as shown in the following table:
Display Header NUM data Andon data line 1 Andon data line 2 Andon data line 3 Andon data line 4 Marquee
Note: This table is under construction. Consult your sales person for the latest version. Display Header = R10C10T & C = MHASCC|A1CELLS!R10C10T & R10C10T
GOAL = MHASCC|A1PROJ!NUM ACTUAL = MHASCC|A1ACTUAL!NUM TIME = MHASCC|SYSTEM!TIME
95
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
MARQUEE =MHASCC|A1MARQUEE!MARQUEE The Tag for the first cell on the second row called R02C01C has the DDE link =MHAAB|BLOCK1!R1 The data type must be an ASCII Decimal since the tag will provide a number between 0 and 15 from the AB PLC that will determine the message text, color and flash properties for the specified Andon Cell:
The MHAAB Server lists all the configured Topic / Item combinations currently addressed by Data Manager:
The only topic configuration available is the ability to change the first slave address from the default of 10 to a different number, to do this, select Configure/Slave Address:
96
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
The Start Address represents the address for Andon station cell R02C01C or the Andon station cell fed by the tag whose DDE path is =MHAAB|BLOCK1!R1 :The Item addresses for R1 through R16 are in octal starting from the Start Address. If the start address (R1) = 10, the following Items will have the following addresses: R1 = 10 R9 = 20 R2 = 11 R10 = 21 R3 = 12 R11 = 22 R4 = 13 R12 = 23 R5 = 14 R13 = 24 R6 = 15 R14 = 25 R7 = 16 R15 = 26 R8 = 17 R16 = 27 Allen Bradley MSG Table Configuration On the Allen Bradley PLC5 equipped with an Ethernet card, configure the following MSG Instruction to communicate with the MHAAB Server on the displays internal PC: For Communication Command use: PLC-2 Unprotected Write For PLC-5 Data Table Address: Select an available area of the Integer data table of the PLC Size in Elements: Represents the number of stations (Items) to be sent to the MHAAB server from this PLC. This number can be from 1 to 32. For the screen being configured in this manual, This number can be from 1 to 16. Port Number: Always 3A Target Device Data Table Address: Used as an offset (from selected Start Address in MHAAB Server) for the first station cell to receive data from this PLC, Size in Elements (above) determines how many station cells will receive data from this PLC. MultiHop: NO Ethernet IP Address: Enter the IP address of the PC running MHAAB server (full matrix display boards Internal PC): Example: To randomly configure four AB PLCs to send data to R1 through R16, configure the first AB PLC to send data to Cells R1 through R4 by configuring the MSG window Size in Elements: = 4 (dec) and the Data Table Address: = 10
97
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual (octal); configure the second AB PLC to send data to Cells R5 through R12 by configuring the MSG window Size in Elements: = 8 (dec) and the Data Table Address: = 14 (octal); configure the third AB PLC to send data to Cells R13 and R14 by configuring the MSG window Size in Elements: = 2 (dec) and the Data Table Address: = 24 (octal); configure the fourth AB PLC to send data to Cells R15 and R16 by configuring the MSG window Size in Elements: = 2 (dec) and the Data Table Address: = 26 (octal). The following table illustrates this particular configuration, any configuration can be used with one to four PLCs:
PLC First PLC Size in Elements 4 decimal Data Table Address 10 octal 11 12 13 14 octal 15 16 17 20 21 22 23 24 octal 25 26 octal 27 Station Cells R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16
Second PLC
8 decimal
2 decimal 2 decimal
Remember; the selected PLC-5 Data Table will contain integer values from 0 to 15 to display one of the following station condition messages for each of the Andon display cells. Which display cells are to be fed by this PLC is determined by the PLC-5: Size in Elements setting for the first display cell offset, and the Target Device: Data Table Address for the number of display cells fed by this PLC: 0 = Black = Blank 1 = Red = FLT = Fault 2 = Red = STP = Control Side Emergency Stop 3 = Yellow Flash = MNT = Control Side Maintenance Call 4 = Green Flash = LDR = Control Side Leader Call 5 = Yellow = LSC = Control Side Light Screen Fault 7 = Yellow Flash = TIP = Control Side TIP Change 8 = Green = BLK = Station Blocked 9 = Yellow = STV = Station Starved 10 = Red Flash = OVR = Station Over Cycle 11 = Yellow = MNL = Control Side Manual 12 = Red = HLD = Control Side Robot (s) in Hold 13 = Yellow = MI = Control Side Manual Intervention 14 = Red = SG = Control Side Safety Gate Open 15 = Green Flash = AUT = Station in Auto 18 = Red = STP = Remote Station Emergency Stop 19 = Yellow Flash = MNT = Remote Station Maintenance Call
98
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual 20 = Green Flash = LDR = Remote Station Leader Call 21 = Yellow = LCS = Remote Light Screen Fault 23 = Yellow Flash = TIP = Remote Station Tip Change 27 = Yellow = MNL = Remote Station Manual 28 = Red = HLD = Remote Station Robot (s) in Hold 29 = Yellow = MI = Remote Station Manual Intervention 30 = Red = SG = Remote Station Safety Gate Open 32 = Yellow Flash = REJ = Perceptron Reject Part 33 = Green Flash = PTW = Perceptron Trend Warning 36 = Red = TRQ = Nut Runner Torque Fault 47 = Yellow Flash = HPR = Hopper Low 52 = Red = TRQ = Nut Runner Torque Fault 63 = Yellow Flash = HPR = Remote Hopper Low Note: The color Black is the same as off and will show nothing in the area designated.
99
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The following four message tables illustrate the configuration required for the example on the previous page: 1st PLC Message Table 2nd PLC Message Table
The following Ladder Logic is an example of how each PLC can be programmed to update the MHAAB Server on a time basis (every minute) and on a data change basis:
100
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Music and Lamp Test Configuration The music and/or lamp test can be accessed by one to 32 PLCs. The addresses are in octal starting with 50 by default. Each PLC will have a MSG table dedicated to music and lamp test data exclusively: PLC
First PLC Second PLC Third PLC Fourth PLC
Size in Elements
2 decimal 2 decimal 2 decimal 2 decimal
Function
PLC 1 Music PLC 1 Lamp Test PLC 2 Music PLC 2 Lamp Test PLC 3 Music PLC 3 Lamp Test PLC 4 Music PLC 4 Lamp Test
To change the default Start Address from the default of 50, open the following menus in the MHAAB Server:
The Music has a priority based configuration and is setup as an "or" function. This means that the largest tune number of the 32 PLC's will be the number that is played until either a higher tune number is sent by another PLC (which will interrupt the current tune) or the PLC that is currently sending the highest tune, sends a higher or lower numbered tune or sends tune number 0 (no tune). If the PLC sending the highest tune, sends a tune with a lower number than a tune being sent by another PLC, the higher numbered tune from the other PLC will take priority and play. Note: Each of the 32 PLCs can simultaneously send tunes but only the highest numbered tune will actually be played on the speaker at any given time. The Lamp Test is also set up as an "or" function. This means that if any of the 32 PLC's sends non-zero number to a lamp test data table address, the board will illuminate all amber LED's. If all of the PLC's show a zero the LED's will return to normal. Note: This section is under construction. Consult your sales person for the latest version.
101
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Special Features for the Data Manager Program and MH Drivers Setting up Music using the MHASCC and MHAAB drivers Click on the Configure menu and select WAV Files:
102
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Enter the number of the Tune in the Tune Number window, enter a Tune Name and click on Browse to locate the Folder that contains the wave file. When finished the window should look like this:
To Modify, select the tune from the main list and click Modify. The filename is the only thing that can be modified. If you want to change the Tune Number or Tune Name you must click on the tune and click Delete. Then click new and re-enter all the information. To Delete a tune, click on the tune from the main list and click Delete.
103
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Setting up the Multi-Channel Music System using the MHASCC Driver Select Sound Channels from the Configure menu in the MHASCC driver
Enter in the group and unit numbers for each sound channel.
104
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Setting up No Comms using the MHASCC and MHAAB drivers
This No Comms window will open. Enter the time in Seconds that you want the driver to monitor communication and click OK (Example 120 = 2 minutes):
Setting up No Comms on the Data Manager for MHASCC Open up Data Manager and under the File Menu select Configure:
Factory Vision Marquee Series Users Manual On the Logger bar select Tags and then edit:
For Flipping pages on the Data Manager, this SDM tag should be created. It should be included with the Electro-Matic Single Block file on the full matrix display. If so you do not have to recreate the tag. If it is not included create a new tag named SDM and insert the DDE link: =MHASCC|A1SCREENNO!SDM. Here is an example of this SDM tag:
106
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual For using No Comms on the MHASCC driver, this TIMEOUT tag should be created. It should be included with the Electro-Matic Single Block file on the full matrix display. If so you do not have to recreate the tag. If it is not included create a new tag named TIMEOUT and insert the DDE link: =MHASCC|SYSTEM!STATUS. Here is an example of this TIMEOUT tag:
For using No Comms on the MHAAB driver, this STATUS tag should be created. It should be included with the Electro-Matic Single Block file on the full matrix display. If so you do not have to recreate the tag. If it is not included create a new tag named STATUS and insert the DDE link: =MHAAB|SYSTEM!STATUS.
107
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Here is an example of this STATUS tag:
108
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual This Window will open on the desktop:
Click on the Start-up Button with the green check mark. This window will now be open:
There is a program included with the Electro-Matic Single Block project on every display board. This program in under the start-up button. So this program is run every time the ElectroMatic Single Block project is in run mode. Below this program is discussed step by step. When you finish making your changes in this program, go under the file menu and save. Then the Application Language window and make sure a green check mark is still next to the Start-up button. If there is a red X, click on the Startup button again and go under file menu and open the startup.dmb file and close the window again. You should now see the green check mark. If you do not see it, repeat the process until you do.
109
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Data Manager Program that controls the Page Flip and No Comms Variable Declaration The top of this program is the declaration of variables that are used in the program. The first three variables are used with the page flip SDM command. The last two variables are used with the No Comms Command. The variable #scrn_no_tag is the current value of the A1SREENNO tag. The variable #scr_no_now is equal to the last changed value of the A1SREENNO tag. The variable #failure is used in the mainloop part of the program. This variable is looking for a change either in the A1SREENNO tag or the TIMEOUT or STATUS tag. The variable #stat_tag is the current value of the TIMEOUT or STATUS tag depending on if you are monitoring the MHASCC or MHAAB status. The variable #last is the last changed value from the TIMEOUT or STATUS tag. Two additional variables can be added if you want to monitor the status of the No Comms communication on the MHASCC and MHAAB drivers at the same time.
declare #scrn_no_tag declare #scr_no_now declare #failure declare #stat_tag declare #last #scr_no_now = 0 #last = 0
Main Program Loop The next part of this program is the mainloop used to monitor a change in either the A1SCREENNO, STATUS or TIMEOUT tags. The line (#failure = GETTAG("a1screenno",#scrn_no_tag)) is grabbing the tag a1screenno and setting it equal to the variable #scrn_no_tag. Then the next line (if #scr_no_now != #scrn_no_tag then goto screenchange) is checking to see if the current value of the a1screenno tag has changed. If it has changed the program will jump to the screenchange part of the program. The line (#failure = GETTAG("TIMEOUT",#scrn_no_tag)) is grabbing the tag TIMEOUT tag and setting it equal to the variable #stat_tag. Then the next line (if #last != #stat_tag then goto screenchange) is checking to see if the current value of the TIMEOUT tag has changed. If it has changed the program will jump to the timeout part of the program. The TIMEOUT tag can be changed to the STATUS tag to look for No Comms on the MHAAB driver or the two lines of code can be copied so both drivers can be checked for No Comms. Of course the variables #stat_tag and #last will had to be changed in the copied part of the code and two new variables will have to be declared at the top of the program.
:mainloop #failure = GETTAG("a1screenno",#scrn_no_tag) if #scr_no_now != #scrn_no_tag then goto screenchange #failure = GETTAG("TIMEOUT",#stat_tag) if #last != #stat_tag then goto timeout wait(1.0) goto mainloop
110
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Screen Flip Program Loop The screenchange part of the program with check the value of the #scrn_no_tag sent from the mainloop program. This value will determine what Data Manager project screen will be displayed on the board. In this example, if the #scrn_no_tag is equal to 1, the program jumps to the template loop. In the template loop the page on the newpic line will be the page displayed on the board. In this case the template.sid will be displayed. If the #scrn_no_tag is equal to 1, the program jumps to the :chart loop. In the chart loop the page on the newpic line will be the page displayed on the board. In this case the chart.sid will be displayed. You can add additional pages to this program or adjust the newpic line based on what page you need to display on the board. You may also want to change the name of each loop based on the name of the page you want to display. For example, if you had a page named test.sid and you wanted to add this to the screenchange part of the program. You would add the line (if #scrn_no_tag == 2 then goto test) to the screenchange loop. Then add a loop called test just like the template and chart loops. Just make sure to set the #scr_no_now = 2 and the newpic (test.sid). :screenchange if #scrn_no_tag == 0 then goto template if #scrn_no_tag == 1 then goto chart #scr_no_now = #scrn_no_tag goto mainloop :template #scr_no_now = 0 newpic("template.sid") goto mainloop :chart #scr_no_now = 1 newpic("chart.sid") goto mainloop
Factory Vision Marquee Series Users Manual project screen will display the timeout page on the board. If the variable #stat_tag is equal to 1 then the program jumps to the nocomms loop located below the timeout loop. This nocomms loop will display the page timeout.sid and then return to the mainloop. If you wanted to add the status loop for the MHAAB driver as was talked about above. Just copy the timeout loop and change it to status. Also, change the variables to the new variables that you created. :timeout #last = #stat_tag if #stat_tag == 1 then goto nocomms goto template :nocomms newpic("timeout.sid") goto mainloop
112
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
This will open the movie file in the windows media player. Once the player is open you can resize the player to make the movie larger or small depending on the size of your LED matrix display.
Once the movie is playing on the desktop of the internal PC there are two options for making this movie visible on the display: 1. Move the media player to the current X and Y coordinates. Remember the X and Y coordinates start at the upper left hand corner and from there they display the available number of pixels from that point. 2. Move the X and Y coordinates from its current location to the location of the media player. This is possible by using the included positioning software. See Chapter 10, LED Panel Set for the Factory Vision displays.
113
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06 RS232/ RS485 Connection Gigatron Board
Ethernet Connection
5 Volt DC Power
The Non-PC Based Displays use one of three communication protocols: 1. Gigatron Native Protocol (GNP) 2. Serial Communications Protocol (SCP) 3. Adaptive Reduced Version Protocol Each of these protocols will be discussed in detail in the next paragraphs.
115
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 10, Gigatron Setup Using LED Set MainMenu with the Factory Vision Displays
A look at the menu bar in LED Set MainMenu.
This is used to configure a Non-PC sign containing a Gigatron unit. This will allow the user to change the IP Address, sign pixel size, overall brightness and serial number. Caution: These are factory set and any changes can cause the sign to malfunction.
This is used to download CPU and FPGA firmware to the signs Gigatron board. These are factory set and changes are made only when required by the manufacturer.
This is used to set the signs brightness on an 8x8 block of LEDs. This is factory set and is only required when an LED component is replaced.
This is used to download font types to a Gigatron used in Non-PC based display.
This is used to configure a display with an internal PC. This software can set the start position coordinates of the internal PC display. It can also be used to set the sign size in pixels, the overall brightness and specify single or double-sided displays. Using System Set for Non-PC versions of the Factory Vision Displays System Set Functionality 116
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Setting the IP Address: Click on the System Set (Non PC) Button.
This will open the System Set Password screen. Enter 1234 and click OK. The password can be changed by entering the current password and re-entering the new password twice.
To Begin working with the System Set, make sure the IP Address window is filled in correctly and click Connect. The default IP Address on all the Gigatron boards unless specified by the customer is 169.254.10.49. This connection to the Gigatron will update the window with the current configuration settings.
117
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
After connecting to the Gigatron, the System Set will display the IP Address and the version of Gigatron software currently loaded on the unit. There are three versions available for the Gigatron. SoftVer: 3XXX - Gigatron Firmware - Loaded on boards containing an internal PC and also on boards without a PC. SoftVer: 4XXX - SCP Firmware - Loaded on boards without an internal PC. SoftVer: 5XXX - ADP Firmware - Loaded on boards without an internal PC. After clicking OK the software will automatically update the system parameters.
When you see the above message the system settings have been updated correctly. Click OK to continue. To change the IP Address, enter the new Address in the IP Addr Box and Click Set Para to sign.
118
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
If the new IP Address is similar to the current IP Address on the Gigatron, the message Set Hard OK will appear instead of the previous message.
Setting the Sign Size, Baud Rate and TCP Timeout: Click on the Sign Para Tab to get to these settings.
Sign Size: Dimension of the sign in pixels. Display Mode: Same Contents - Same information on each side of a double-sided display. Different Contents - Different information on each side of a double-sided display. In a board using an internal PC the second side will start at the same column and row + 128 pixels from the current row setting. FPGA Len: This is calculated automatically. This is used to help with the brightness adjusting. Position: This is the starting position of the sign. For a Non-PC unit this should be set to Start Col: 1 Start Row: 0. Hit the Default button to change to these settings. Baud Rate: Sets the Baud Rate of the Master Board. TCP Timeout: Set the TCP timeout of the Ethernet connection (From 0 - 255). MAC Addr: Displays the current MAC Address of the Gigatron Board. Do not change the MAC Address window. Sign Type: Select RG(8:8) for a tri-color display and RGB(5:6:5) for a full color display. 119
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Setting the Baud Rate: Click on the pull down menu to change the Baud Rate. The default setting is 9600 Baud. After changing the rate click on Set Para to sign to complete the change. Setting the TCP Timeout: The TCP Timeout is set in minutes (0-255). The default setting is 0. This means that the sign will never break connection from the network. If you change the time to 5 minutes for example, after 5 minutes of no activity the sign will break the TCP/IP connection. After changing the timeout settings, click on Set Para to sign to complete the change. Additional Settings on the System Set Menu: Click on the Tools Tab to get to these Settings.
Serial Number: A number that can be unique to each display. This is displayed on the startup screen when the unit is powered up. Click Get SN to read current setting and enter a new number and click Set SN to change. Brightness: Overall brightness on the display. Range is from 0 to 128 (max). Click Get to read current settings or enter a new brightness value and Click Set to change the current value on the display. 120
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Using Update for Non-PC versions of the Factory Vision Displays Update Functionality Click on the Update Button.
This will open the Update Password screen. Enter 1234 and click OK. The password can be changed by entering the current password and re-entering the new password twice.
To connect to the Gigatron unit make sure the IP Address and Tran Mode is correct. The default for a board with an internal PC is RS232/485 and serial port Com2. The default for the IP Address is 169.254.10.49. (Note: If the Users Computer IP Address is not of the segment 169.254.10.x, then the user needs to modify the IP Address of the computer to make it the same as the sign.) If communicating via Serial Port, just select RS232/485 and the exact serial port of the PC to connect to the display. After setting the IP Address of the Gigatron and the Tran Mode Click Connect.
After connecting to the Gigatron, the Update will display the IP Address and the version of Gigatron software currently loaded on the unit. There are three versions available for the Gigatron. SoftVer: 3XXX - Gigatron Firmware - Loaded on boards containing an internal PC and also on boards without a PC. SoftVer: 4XXX - SCP Firmware - Loaded on boards without an internal PC. SoftVer: 5XXX - ADP Firmware - Loaded on boards without an internal PC. Click OK to continue. Make sure CPU is selected in the program type and Click on the button to select the new version of firmware to load.
122
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
After selecting the button, the menu to select the .bin file will open.
Pick the verXXXX.bin file that you are planning to load into the Gigatron and click Open. The File Name box will now show the link to the CPU .bin file that is set to be loaded
Click Updata to download this file. Important: 1. Make sure not to shut off power on the display while downloading, or the download failure will result in an unrecoverable Gigatron unit that must be physically replaced. 2. While downloading the .bin file, if a communication error occurs make sure to not shut off the power, just continue downloading. 3. If power is accidentally cut off while downloading, the unit will have to be sent back to the factory for repair.
123
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Click on exit to close the Update program. Using LED Match for all versions of the Factory Vision Displays LED Match Functionality The LED Match Software is designed to set the brightness of specified blocks of LEDs on the sign to assure optimal consistency and uniformity of color and brightness. Click on the LED Match Button.
To connect to the Gigatron unit make sure the IP Address and Tran Mode is correct. The default for a board with an internal PC is RS232/485 and serial port Com2. The default for the IP Address is 169.254.10.49. (Note: If the Users Computer IP Address is not of the segment 169.254.10.x, then the user needs to modify the IP Address of the computer to make it the same as the sign.) If communicating via Serial Port, just select RS232/485 and the exact serial port of the PC to connect to the display. After setting the IP Address of the Gigatron and the Tran Mode Click Connect. 124
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
After connecting to the Gigatron, the Update will display the IP Address and the version of Gigatron software currently loaded on the unit. There are three versions available for the Gigatron. SoftVer: 3XXX - Gigatron Firmware - Loaded on boards containing an internal PC and also on boards with a PC. SoftVer: 4XXX - SCP Firmware - Loaded on boards without an internal PC. SoftVer: 5XXX - ADP Firmware - Loaded on boards without an internal PC. This connection to the Gigatron will also update the size of the display to the LED Match software and show a block of LEDs on the internal PC or on the remote PC depending on what type of Factory Vision Display you are currently using. Click OK to continue. Below is an example of what is displayed on the screen. The matrix is made up of 8x8 pixel blocks. These blocks can be adjusted individually or in a group. Each 8x8 block is mounted on a driver unit that is 64x16 pixels.
125
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
To begin the LED Match software click on the Tools menu and select Read Brightness. This will pull the brightness file from the gigatron to the LED Match software. The Read Brightness icon on the toolbar can also be used.
Now select the side you want to adjust. For a single-sided board select Side A for a double-sided board you can select either side A or side B. This can be selected on the toolbar or under the tools menu.
126
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
After selecting the correct side, the colors for the display should be selected. For example if you want to adjust the green portion of the LED tiles you must set it up for green, etc. For a Non-PC display follow these instructions: Click on the Test menu and select the color that you would like to adjust on the display. It is recommended that you select Screen All Red or All Green. This is due to the fact that the tricolor displays are made up of Red and Green LEDs.
When finished matching the tiles remember to go back and click test menu and end test. For an internal PC display follow these instructions: Click on the tools menu and select Options or select the Options icon from the tool bar.
Here are the options to adjust on the Led Match options menu: Load Image: Allow the user to load an image into the Led Match simulator. Fore Color: The background color on the Led Match Simulator. Recommend using red or green to match the tiles. Line Color: The color used on the grid lines of the Led Match Simulator. Recommend using black to show the grid lines on the tiles. Select Color: The color used on the selection area of the Led Match Simulator. Select border color: The color used for the selection border in the Led Match Simulator. Recommend using Amber to show the selected section with the red or green background. Recommend using Matrix Size: For tri-color displays the Matrix size is 8x8. After setting up the colors for you display click OK to continue. For all displays begin following these instructions: Drag and select the area or just select the block that you want to adjust.
128
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Once the area or block is selected click on menu and select Set Brightness or select the sun icon on the toolbar.
This will open a slider that will give you control of the red and green portion of the LEDs. Enter the number of move the slider to change the brightness of each color.
After changing the intensity of the color a pop up box will let you know that this new brightness data was sent okay to the Gigatron board. Note: If a large section is chosen for adjustment, this brightness adjustment can take several minutes before you see the below pop-up box.
Click OK to continue. Additional LED Match Tools for Non-PC Displays Click on the Test menu and select one of the following items to test the LEDs on the display. Select Screen All Red, All Green or All Yellow to light up the LEDs Select Horizontal or Vertical Scan to test the LEDs functionality Click End Test to turn off any of these tests.
Using LED Panel Set for PC versions of the Factory Vision Displays LED Panel Set Functionality LED Panel Set will allow the user to change the coordinates of the display, the Sign Size, the overall brightness, and the display mode. Click on the LED Panel Set Button. 130
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
To connect to the Gigatron unit make sure the IP Address and Tran Mode is correct. These settings can be found on the communication tab. The default for a board with an internal PC is RS232/485 and serial port Com2. The default for the IP Address is 169.254.10.49. (Note: If the Users Computer IP Address is not of the segment 169.254.10.x, then the user needs to modify the IP Address of the computer to make it the same as the sign.) If communicating via Serial Port, just select RS232/485 and the exact serial port of the PC to connect to the display. After setting the IP Address of the Gigatron and the Tran Mode Click Connect.
131
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
After connecting to the Gigatron, the Update will display the IP Address and the version of Gigatron software currently loaded on the unit. There are three versions available for the Gigatron. SoftVer: 3XXX - Gigatron Firmware - Loaded on boards containing an internal PC and also on boards without a PC. SoftVer: 4XXX - SCP Firmware - Loaded on boards without an internal PC. SoftVer: 5XXX - ADP Firmware - Loaded on boards without an internal PC. This connection to the Gigatron will also update the size of the display along with the coordinates to the LED Panel Set software. Click OK to close this box.
Click OK to close the Get hardware msg box. Setting the Coordinates on the display: The display on the internal PC is set for 640x480. These coordinates below allow the user to move anywhere within that display. The coordinates start at 0,0 and go to 640,480. To move the location of the LED display, pick the new coordinates and click the Set Para to sign button and click OK to continue. These coordinates set the upper left hand corner of the display. The rest of the display is filled in to the right and down from that point.
132
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Setting the Sign Size of the display: This setting will only be changed if a user is setting up a new Gigatron. This setting should be set correctly when it ships from the factory. To change the size, enter the new size in pixels and click Set Para to sign to make the change. Click OK when finished. If this is set incorrectly, the sign will typically have a multitude of every color on the display portion that is undefined because of a size that is too small. If the sign is set too large then the display will shift up and to the left depending on whether it is the height or width that is incorrect.
Setting the Overall Brightness on the display: This setting will allow the user to change the overall brightness of the display. The range is from 0 - 128. This setting should be set to 100 when it ships from the factory. To change the brightness, enter the new number and click Set Para to sign to make the change. Click OK when finished.
Setting the Control Mode on the display: This setting will allow the user to change the control mode on the Gigatron board. The VGA SYNC mode means the Gigatron will display directly from the internal PC or in the OFF-LINE mode the board will display directly from the Gigatron. The offline mode makes the unit act as a marquee instead of a full matrix display. To change the control mode, select the circle and click Set Para to sign to make the change. Click OK when finished.
133
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Setting the Display Mode on the display: This setting will allow the user to change the display mode on the Gigatron board. The Same Contents mode means the Gigatron will display the same portion of the internal PC display on each side of the board. The Diff. Contents mode allows the user to look at two different portion of the internal PC display on each side of the board. The first side will display the coordinates chosen in the position section of the LED Panel Set and the second side will start at the same column and row + 128 pixels from the current row setting. To change the display mode, select the circle and click Set Para to sign to make the change. Click OK when finished.
Offset Position: This setting is set at the factory based on the internal PC used in the Factory Vision display. This setting should never have to be changed.
MAC Addr: This is the MAC Address that is set at the factory. This setting should never have to be changed.
Sign Type: This is the type of sign that is being controlled by the Gigatron. The RG(8:8) is for the tri-color LEDs and the RGB(5:6:5) is for the Full Color LEDs. This is set at the factory and should never have to be changed.
134
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
1.
2.
File Menu File|New Font List: This menu is to get out font list interface. Also you can select this to download fonts to signs master board. Hot key: Ctrl+N. File|New Font: Click this to create new fonts, hot key: Ctrl+Alt+N File|Open: To open a font list file. File|Convert font: To convert Windows fonts into the format that Gigatron can recognize. File|Exit: To exit the software. Window This menu is to manage the interfaces that youve opened, there are three drop-down list: Tile, cascade, ArrageIcons. Help Click this menu to get help information of the software operation and detail description of this current version. 3. Operations Interface introduction Select File|New Font List from the menu to pop up the following interface:
135
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
File List Area Description of the menu and buttons: Font List|Add: To add a new font file to the File List Area. Also click the button do. Font List|Delete: To delete a font file from the File List Area. Or click the button . Font List|Edit: To select a font file from the File List Area and to edit it. Or use the button . Font list|Move up: To move a file to a upward place. Or click the button. Font list|Move down: To move down a file in the File List Area. Or use the button . will
Font list|Update Font List: to download the font files to the memory of signs master board from the File List Area. Detail Operations of Font File List editing To edit the font list file, first add the file to the File List Area. As per the following figure, to add the file Char15.fnt to File List Area:
136
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Click the font file, and the selected font file will turn highlight. Then use the button the following interface:
to get out
The above figure shows the interface of font file Char_15.fnt. Now you can select some character to edit. 137
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Font Description Description of the Icons in the Tool Bar: : To open Font List File or Font File : To save the current edited file : To clear the Font Editing Area as an eraser
138
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
: To move to the font downstairs. If current editing character is A, there will prompts the downstairs character B after clicking the button, as per the following figure:
: To zoom in the font editing area to original size : To zoom out the Font Editing Area in a certain proportion. : To zoom in the Font Editing Area in some proportion. : To exit the font managing software.
139
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
1.1 Editing the characters: a) Press left button of the mouse and slide it to draw lines in the blank squares of Font Editing Area or left click to draw dots in blank square:
Press left button and slide the mouse to draw lines in blank squares
b)
Press right button of the mouse and slide it to clear the lines or click in the dotted
140
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
c) d)
Use the button to clear the whole font editing area. Sometimes we need some other fonts except for those available in this software, in that case we have two solutions. One is to create new fonts by editing it in Font Editing Area, the other is to take over some that are available in Windows system to replace the current ones, do as the following: Select the font you need in Windows
Seeing the figure above, we select the font MS Serif, set the size 10, and input A in the bottom blank:
141
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Click to save the replacement and now we finish replacing the character A in Char-15 font with that in MS Serif font. The user can also replace the current editing fonts with any other fonts he likes. : The font replacement we do here operate against just the single character that is edited in the Font Editing Area, not the whole font list. So after we download the new font list, only character A is in font MS Serif, while the rest of the font list are still in font Char_15.
142
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
143
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
1.2 Edit special character Font size too big, beyond the Sometimes the user may want to display some special current resolution characters, which are not available in the original font list. In that case, the user needs to edit the character manually. For example, if the user wants to display the character , how to edit it? Let us suppose the current font is Char-15.fnt, do the following to add to the font list the character : Select the menu File|Open on the Font Editing interface, and you will see the following pop ups:
144
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Press 00C
and
drag
the
Rolling
Bar,
click
the
blank
character
in
the
square
145
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
146
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
147
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
: If there isnt any blank square left when opening a font list file, use add button to add a new line of blank square, as per the following figure:
Click to add a new line of blank square : In the case that the user uses some special character very often, while seldom use certain character exiting on the keyboard, we can do the replacement for convenience. Lets explain by an example. Suppose the user often use character , and seldom use the character @, however. The user can just replace @ with per the solution we provide above. And now its made more convenient for the user to input , just by pressing the key @ in the keyboard.
148
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Select the font style, font size and specify the route to save the file in the above dialog. Check the options in the checkbox on the left of the interface to select the language to convert to. Finally click the button to accomplish converting. c) After converting, there will be the following pop up:
149
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
d)
Now lets click some character by chance to view the new font description. Suppose its S, double click on it to enter Font Editing interface:
e)
From the interface above, we learn the resolution of the converted font: 16 dot high, 8 dot wide. We can edit the character and re-convert it so to make it suit the dot matrix of the sign.
150
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Input the font width, font height of the font to create and specify the rout to save it:
b)
Secondly, when creating new font, make sure to create the character exactly per its right place in ASCII code. For example, when we create character o, we should create it in the square of 30H. Only by creating it in that square can we get o when we press the 151
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
152
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
d)
Click
to save the character and create the other characters following the same steps.
: When the user create new font, make sure not to choose a font that occupies the full dot matrix of the Font Editing area. There must be some clearance between the neighboring characters and text lines, in case that there is overlap between the characters or lines. We recommend leaving one row of dot horizontally and vertically. 1.5 Download all font files After finishing editing the fonts, the user need to download all font files to the memory of Signs master board. Be sure to download all font files, that is, not just download the font file that youve edited. Each time we download new data to master board, the master board will be cleared of all preset data. So when downloading, ensure that all needed font files are downloaded. Any font files that is not downloaded in the new downloading will be lost.
153
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
b)
Use the Add button to add to the File List Area all font files that you want to keep:
154
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
You can not use the Dot Matrix Editor Software and the Font Management Software simultaneously. When download all font files, please make sure to list the file Normal5.fnt and Normal7. fnt as the first two files. The user has to follow this sequence. When the sign is switched on, it will display a message of signs description (Signs dot matrix, hardware program version). And it is set that this message must be displayed in Normal5.fnt and Normal7.fnt. Otherwise it will be displayed in a mess. There isnt any sequence restrictions for other files.
155
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
LedPanelSet software
LedPanleSet software is used to set parameters of panel, such as to set the play modes: synchronicor off-line, and also to set the display area, and if double-sided display, to display the same content or different content, etc, the operations are as following: 1. Introducing the interface: Click the button to get out the interface below:
156
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Specify Com mode and sign IP address in the above interface.
When the display is set synchronism mode, this parameter is used to set the location of what the display play in the internal computer, if the display in off-line mode, this parameter is invalid.
To set the synchronism mode or off-line mode Each side of sign will be different. 2nd side of sign is +126 rows down from 1st side start position and at same column
Display area size
To specify whether to display the same content on two sides in case of double-sided sign. To set brightnes
2. Operations 1) Specify communication mode and sign IP address, then click connect button: to build up communication between sign and PC. If communication successful, the button Get Para from sign and Set Para to sign are enabled. 2) Click button Get Para from Sign to get back sign configurations. 3) Specify sign parameters in Sign Para interface and then click the button Set Para to Sign to finish it. Note: Off-Line button is used for Non PC versions of displays. Communications to the sign ids done with RS232/RS485/Ethernet utilizing one of the three protocols: Gigatron, Adaptive or SLC.
157
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
158
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
159
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
160
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
161
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
162
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
163
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
164
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
165
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
166
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
167
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
168
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
169
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
170
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Appendix A PC Anywhere Usage/Configuration pcAnywhere is used to allow a programmer to start and configure MHASCC and MHAAB TCP/IP DDE Servers, the Data Manager HMI program and the EasyMAP program which resides on the display boards internal PC, from a remote PC on the Ethernet network. Before communication can be established, PC anywhere must be loaded and configured: 1. As a Host on the display boards internal PC and 2. As a Slave on the remote PC. PC Anywhere on the Display boards Internal PC: Normally the display board is delivered from the factory with pcAnywhere loaded and configured as a host with a customer specified IP address. To configure the host PC within the display board, plug a monitor, mouse, keyboard into the display board connections located either behind a door on the end of the display board or behind the front LED panel. Start pcAnywhere with the following windows desktop icon:
To set up sign as a host on pcAnywhere..... Select Be a host Button which provides host connection selections:
At the bottom right corner of screen, small icon indicates that the PC is waiting for a connection:
171
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual PC Anywhere on the Remote PC or Laptop: This allows the user to establish a remote connection from a PC to a display board. Open pcAnywhere on a remote PC connected to the same Ethernet network as the display board:
Select network icon which causes a search of the TCP/IP network for a host (In this case, the display board PC)
A window will appear that indicates that pcAnywhere is: Initializing communications Scanning for TCP/IP Hosts Waiting for selection from table listing available hosts Select the host address you want to connect with and select OK:
172
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
You should now see the same display as is on the host PC and the display board:
173
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Appendix B Alpha-Sender II and Quick Sender Programs POS Multi-Use Protocol The POS Multi-Use Protocol is used to send sign data to the Goal, Actual and Time fields and the first and third row of eight Andon cell fields. The second and fourth rows of eight Andon cell fields are programmed to accept data from up to four Allen Bradley PLCs. The following is an examination of a demo program (called Ford_Test_MH1.txt) which uses the POS Multi-Use Protocol to populate the sign with Andon style information that change color from Red to Yellow to Amber. (lines two and four are not addressed in this example) The utility used to send this demo program to the sign is the Electro-Matic Alpha-Sender II Program. The end user of the Electro-Matic Full Matrix Process Display board will need to develop a software program to send message information to the sign.
Alpha-Sender II Program Introduction The Alpha-Sender II program can be used as a method of sending strings of hex or ASCII characters to the MacDonald Humfrey Full Matrix Process Display board. For the purpose of this document, Alpha-Sender II will be used to send MHASCC data to the MHASCC server which will convert the Ethernet data to DDE data to be read and displayed by the Data Manager HMI program.
174
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Verify the following window:
175
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual The Following program will appear:
176
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Select line number where edited line is to be placed:
To change program line Interval in milliseconds, select line number and change Interval field:
To ensure that the Alpha-Sender II communicates via Ethernet, select Communication/Set Port and select 0 (0 will set the port to communicate through Com Port 1) To Set the IP and port address of the computer which the AlphaSender II program is going to send code to, select
Set IP address to target PC (display board) and set port to 3001 (always).
177
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Starting Quick Sender From remote PC window, start Quick Sender program:
A menu including Add Group, Clear Group, Add New and Clear will appear on the screen:
First, add a new group (A group must be added before an IP address and board name can be added) Click on Add Group:
178
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Enter in the name of the Group (Example Body Shop) and press OK:
The new Group Name should now appear in the Group Window:
179
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Enter in the Group to associate with the IP address and Board name:
The new IP address and Board name should appear in the window:
*Repeat these steps to enter in additional Groups and IP addresses that are associated with a display. Show All Groups To show all the Groups, click on Show Groups:
This window should appear displaying all the groups and associated IP addresses:
Click OK to clear away the window. Send an immediate message to a display Click on individual to send to a single display:
Then select the IP address or associated board name where the message will be sent:
180
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Make sure the port and GG/UU is set correctly (default for the port is 3001 and default for group (GG) is 01 and unit number (UU) is 30 hex (48 decimal):
The message should now be sent to the display. Send a Group of Timed Messages to a display or Group of displays Select individual or group to send to one display or a group of displays:
Then select the Group for a group of displays or an IP address or associated board name where the message will be sent: Make sure the port and GG/UU is set correctly (default for the port is 3001 and default for group (GG) is 01 and unit number (UU) is 30 hex (48 decimal): Enter your first message in the message to send window: Select Create Event to set the time you want the message to display:
181
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Enter in the start time Hour (24-hour format) that this message will start to display:
Enter in the start time Minute that this message will start to display:
Enter in the Hour (24-hour format) that this message will be turned off:
182
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Repeat this process to add additional messages to display. Click on Enable events to run the events that you created for the display or displays.
When the red box changes to a green box with Event Enabled displayed the events are running and the messages will be sent to the display or displays. Keep the events enabled as long as you want the messages to be sent to the display.
Click on Disable Events when all the messages have been displayed. Remember to not overlap the times and to put the first message at a time that will be after you start the program running. If the message start time is before the events are enabled the first message will not display. Delete Quick Sender Items To delete an event, click on Delete Event and enter the number of the event to delete and click OK:
183
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Then enter the number of the group you want to delete and click OK:
This should delete this Group. To delete an IP Address or Board Name, Click on Clear:
Then enter the number of the IP Address or Board Name that you want to delete and click OK:
Factory Vision Marquee Series Users Manual Save a File to start up when the Quick Sender program is started Click on File then Save:
This file will automatically start the next time the program is opened.
185
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Appendix C MHASCC Serial Communication Protocol Table of Contents Page 1.0 MHASCC Serial Communication Protocol....................... .... 69 1.0.1 NUM Command: Numeric Display Command ................. .... 69 1.0.2 TX1 Command: Text Command................................ .......... 69 1.0.3 AW1 Command: Write Values & Attributes ............... .......... 70 1.0.4 AC1 Commands: Activate Attributes .................................... 72 1.0.5 CLR Command: Clear .......................................................... 74 1.0.6 TIM Command: Time Command .......................................... 74 1.0.7 852 Marquee Command: Marquee Command ..................... 75 1.0.8 SDM Command: Page Flip Command ................................. 75 Appendix A: Command Examples..................................................... 75 Appendix B: ASCII Control Codes..................................................... 76 Appendix C: Glossary of Acronyms & Abbreviations......................... 77
Revision History
Date 7/7/04 Revision Description of Change 1.0 Original Version Initials NRT
Copyright
Copyright 2004 MacDonald Humfrey (Products) Ltd.. All rights reserved. Factory Vision is a registered trademark of MacDonald Humfrey (Products) Ltd.
186
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Disclaimer Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without written permission of MacDonald Humfrey (Products) Ltd.
1.0 MHASCC Serial Communication Protocol Via MHASCC software control, the Full Matrix displays can be configured to respond to either marquee text commands (TX1) or Andon Cell commands (AW1, AC1). Many of the following additional commands apply: NUM, 852 Marquee, SMD, TIM and CLR. 1.0.1 NUM Command: Numeric Display Command The NUM command is issued to display a number in a specified location on the display. The NUM command will by default display a 0 on the display on startup. This value will remain in this location until another NUM command is sent to the specific group and unit number. The values that are stored on the display will be lost on startup. NUM command syntax: ESC NUM nnnn N a A Where: ESC =(required) the ASCII control code escape NUM =(required) ASCII string NUM(stands for Numeric Display Command) nnnn =(required) the numeric data field (numbers to be displayed) (Valid digits are 0-9, hyphen,blank, and decimal point) N =(required) the character N (stands for Number) Note: The following parameters are optional and will be accepted as long as they do not effect the error proofing operation of the board. a =attribute Where a is: 1 = hold (default, if a is not supplied) A = Attribute Terminator 1.0.2 TX1 Command: Text Command The TX1 command is issued to display text messages on a specified row in the display board. If the specified row is currently in an ANDON configuration upon receipt of the TX1 command (meaning it is currently displaying cell values), the light board will blank the current cell values and, instead, display the text message with the specified display attributes. The TX1 command will not remove the cell values that are stored in non-volatile memory (values that have been configured using the AW1 command).The text sent by the TX1 command will be stored in volatile memory and will continue to display until one of the following occurs: The row receives a subsequent TX1 command The row receives a CLR command (clear command) After receiving an RST, CLR or TS1 command, the row will return to an ANDON configuration. TX1 command syntax: ESC TX1 yy R a A p P s S[xyz]
187
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Note: If any of the optional parameters above are chosen, then the corresponding parameter terminator (A, P or S) MUST also be included. [xyz] = Text to be displayed (THIS IS A REQUIRED FIELD) If the backslash character or either of the bracket characters are to be included in the text, they are to be preceded by the back-slash character. Examples: \\ \[ \] Example of a TX1 command: 0x02 0202 0x1b TX13R1A3P[Hello There] 0x04 This will establish that row 3 will change to a text-only row and display Hello There (quotes will not be displayed) in a green, holding state.
188
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
This will establish that a new bin file will be activated and written into FLASH.
Where: ESC = (required) the ASCII control code escape AW1 = (required) ASCII string AW1 (stands for Andon Cell Write type 1) yy = (required) the Andon cell row number, in ASCII decimal (1 to 99) R = (required) the character R (stands for row) xx = (required) the Andon cell number, in ASCII decimal (1 to 40) C = (required) the Character C (stands for column) p = (optional) the primary display color default for the text in the cell where: 0 = black (off) 1 = red (default) 2 = amber 3 = green 4 = light red 5 = yellow 6 = light green 7 = brown 8 = orange P = (optional) the character P (stands for primary color) s = (optional) the secondary display color default for the text in the cell where: 0 = black (default/off) 1 = red 2 = amber 3 = green 4 = light red 5 = yellow 6 = light green 7 = brown 8 = orange S = (optional) the character S (stands for secondary color) a = (optional) the Andon cell default attribute where: 0 = off 1 = on solid (default if A is unspecified) 2 = normal flash (1 second cycle) 3 = fast flash (1/2 second cycle) A = (optional) the character A(stands for attribute) [xyz] = (required) text to be displayed 189
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Where: 190
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Set color value for bin (Red, Yellow, Green) Set Font for bin (Standard, doublewide.) The AC1 bin commands will be held in volatile memory and will clear on any subsequent command addressed to the cell in which it is being displayed. AC1 commands that do not define command attributes will utilize the attributes previously as sent to the cell and bin using the AW1 command. . 1.0.5 CLR Command: Clear The CLR Command is used to clear the display of a specified row or the entire board. The CLR Command will not remove any values from non-volatile memory. The CLR command will only blank the current display of Andon cells or text messages. CLR command syntax: ESC CLR yy R
CLR Command can be issued by inputting character CLR. CLR is issued to blank all rows and messagesincluding the specified TX1 defined Text row or to restore to Test Mode.
Where:
ESC = (required) the ASCII control code escape CLR = (required) ASCII string CLR (stands for Andon light board clear) yy = (optional) is the Andon cell row number, in ASCII decimal (1 to 99) R = (optional) the character R (stands for row) If Row 0 is specified the entire board will be cleared.
Examples: 0x02 0904 0x1b CLR3R 0x04 This will establish that row 3 display will be turned blank. 0x02 0904 0x1b CLR 0x04 This will blank the entire board. 1.0.6 TIM Command: Time Command This command allows the user to set the current time and date on the display. The display will then keep this time. In order to ensure that the time displayed remains accurate to the level of precision desired, the user may re-send addition TIM commands, at their discretion, to update the display.
192
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
a = (optional) the display format where a is: 1 = 12-hour 2 = 24-hour A = (optional) the character A (stands for attribute) Examples: 0x02 0000 0x1B TIM 12:34:00 T 2004-12-23 D 1 A 0x04 This will establish a time of 12:34 PM, a date of 12-23-2004 and the time will be in 12-hour format .
1.0.7 852 Marquee Command: Alpha-Numeric Marquee Command This command allows the user to send alpha-numeric characters to a marquee line on the display. Each line will have a unique group and unit number, and the lines will be controlled independently. 852 Marquee command syntax: 0x0D alpha-numeric data Where: 0x0D = (required) the ASCII control code for carriage return (begins the line). alpha-numeric data = (required) the alpha-numeric string. Examples: 0x02 0101 0x0D This is a Test Message 0x04 This will display This is a Test Message on the specified marquee line.
1.0.8 SDM Command: Page Flip Command This command allows the user to change the current display to another existing display based on a numeric value. Each template will have a unique number, and each template will be controlled independently. SDM command syntax: ESC SDM m M Where: ESC = (required) the ASCII control code escape. m = (required) the number of the template page. M = (required) terminates the number field. 193
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
APPENDIXES
APPENDIX D: COMMAND EXAMPLES A. 1: Command Summary
The following list is a summary of the commands covered in this manual:
System Commands
Factory Vision-Tri-Color Alpha-Numeric Marquee (TX1) Text Command STX gg uu ESC TX1 yy R a A p P s S f F [xyz] (NUM) NUM Command STX gg uu ESC NUM nnnn N a A (AW1) Write Values and Attributes to ANDON Cells STX gg uu ESC AW1 yy R xx C p P s S f F j J a A [xyz] bb B (AC1) Display/Activate Attributes for Values Stored in ANDON Cells STX gg uu ESC AD1 yy R [cc, cc, cc, cc, cc cc] (CLR) Clear STX gg uu ESC CLR yy R (TIM) Time Command 0x02 gg uu 0x1B TIM hh:mm:ss T yyyy-mm-dd D a A 0x04 (952 Marquee) 952 Marquee Command 0x02 gg uu 0x0D Alpha-Numeric Display 0x04 (SDM) Page Flip Command 0x02 gg uu 0x1B SDM m M 0x04
194
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual A.3: Additional Command Examples
The following command examples are shown with a GROUP address of 03and a UNIT address of 04. Example #1: Select the Andon cell in row 3, column 5, set to fast flashing, color to amber. $02 $30 $33 $30 $34 $1B $41 $43 $31 $33 $52 $35 $43 $33 $41 $32 $50 $04 STX 0 3 0 4 ESC A C 1 3 R 5 C 3 A 2 P EOT
APPENDIX E: ASCII CONTROL CODES In the key column in the table below, the caret (^) before each character represents the CTRL key on the keyboard . Hex Dec Key ASCII ASCII Description SCP Usage Name $00 00 ^@ NUL Null $01 01 ^A SOH Start of Header $02 02 ^B STX Start of Text STX $03 03 ^C ETX End of Text ETX $04 04 ^D EOT End of Transmission EOT $05 05 ^E ENQ Enquiry ENQ $06 06 ^F ACK Acknowledge ACK; also set specific cell $1B 27 ^[ ESC Escape ESC APPENDIX F: GLOSSARY of ACRONYMS and ABBREVIATIONS AKA DRAM EEPROM EOT ESC ETX SCP STX TBD Also Known As Dynamic Random Access Memory Electrically Erasable Programmable Read Only Memory End of Transmission (ASCII control code) Escape (ASCII control code) End of Text (ASCII control code) Serial Communication Protocol Start of Text (ASCII control code) To Be Determined
195
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series User Manual Chapter 12 Networking Hardware for Communications to Non Computer Displays RS-232 Networking
Controller (Computer)
RS-232 Networking An RS-232 Network is a simple point-to-point network that connects two stations: the controller and one sign. To make this connection, you will need a DB-9 to RJ-12 adapter and a 6 pole flat telephone style cable with RJ-12 type connectors on both ends. The maximum length for this cable is 50 ft at 9600 baud. Shown below is the recommended adapter and cable. Description 1. Adapter part number 2. Cable part number Part Number FVZRJ12DB9 FVZRS232FCFX0 (Where X= 1, 2, 3, 4, 5 and Determines the 10s of Feet of Cable i.e. 2 = 20 Feet)
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
196
Controller (Computer)
5 Description RS232 to RS485 Converter RS485 Two Wire Cable Network Adapter RS485 Jumper Cable Terminator Part Number FVZC232-485 FVZC1TPS FVZMARJ11 FVZRS485FC-1 FVZTERM
1. 2. 3. 4. 5.
RS-485 Networking allows a single user to control multiple signs over much greater distances than what is available via RS-232. Without using repeaters, up to 32 stations can be connected on a network that can be up to 4000 ft from start to end. All of the signs should be assigned unique addresses or group-unit IDs in an RS485 Network. They must also be set to the same baud rate on the serial port. *Refer to Chapter 10 of the Factory Vision Marquee & Andon Display Users Manual, for how to set Baud Rates for the signs.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
197
The picture above is a condensed version of what such a network looks like: At the start of the network is the RS-232 to RS-485 converter used by the controller, PC, or PLC. From the converter is a shielded twisted pair cable (RS485 Two-Wire Cable) that runs to the first wiring boxs (Network Adapter) terminals. A one-foot flat cable (RS485 Jumper Cable) runs from the wiring box to the first sign. Then shielded twisted pair cable runs from the terminals of the first wiring box to the terminals of the second wiring box. A one-foot flat cable runs from the second wiring box to the second sign. And you continue until all signs have been networked together (given the distance and drop limitations mentioned above). If more drops or a greater distance is needed, a repeater can be added for an additional 4000 feet and 32 drops. Note that a repeater does count as a drop on the source network. Also note the one-foot flat cable (RS485 Jumper Cable) must be made shorter as network speeds go above 9600-Baud Rates because this can cause signal reflections.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
198
Factory Vision Marquee Series User Manual Factory Vision RS-232 to RS-485 Converter (FVKCONV232-485)
6 1-3
Shown above are the components needed to talk to a Factory Vision Display from an RS232 sending device. These are purchased assembled as a kit under part number FVKCONV232-485.
Description 1. RS-232 to RS-485 Converter 2. Wallmount 9 Volt Power Supply 3. DB9 to RJ45 Adapter Cable 4. Network Adapter Wiring Box 5. Cable- Shielded Twisted Pair 6. Cable 4 pole flat telephone
Part Number FVZC232-485 Included with 1 Included with 1 FVZMARJ11 FVZC1TPS FVZRS485FC-1 (1ft.)
Note that parts 1-3 are included in the same kit this is the non-isolated 110VAC version. Versions with 230VAC or optical isolation are also available. You will need one network adapter wiring box for each sign that is in your RS-485 network. Part number 6 is the cable that runs from the wiring box to the RJ-11 connector on the sign. (NOTE: Due to RS485 Restrictions FVZMARJ11 must NOT be longer than 1 foot or network problems will occur.) This is a straight-through connector: if you look at both ends, you will see that the color coded wires are in the same order from left to right and that there are 4 wires.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
199
Shown above is the wiring in the Network Adapter Wiring box: The Black terminal wire is RS-485 + (B) and the yellow terminal wire is RS-485- (A).
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
200
Shown above is the wiring to the converter terminals: Terminal 1 is RS-485+(B) and Terminal 2 is RS-485- (A).
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
201
Shown above is what the converter will look like when it is connected and ready to drive a sign. Under normal operation, the pwr and cts LEDs will stay lit, and the txd LED will flash as you transmit data to the sign.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
202
Factory Vision Marquee Series User Manual Ethernet and RS485 Networks
All of the FactoryVision Non Computer signs will echo incoming ethernet data out the RS-485 port; using this, a controller can communicate with multiple signs through one ethernet drop. All signs will ignore messages that are not addressed to them. The following would be an example of such a configuration.
3 2 4 1 5 6 FactoryVision Products And Messaging 4 5 6 5 4 FactoryVision Products And Messaging FactoryVision Products And Messaging
1. 2. 3. 4. 5. 6. 7.
Description Ethernet Cable Ethernet Switch Ethernet Cable Network Adapter RS485 Jumper Cable RS485 Two Wire Cable Network Terminator
Part Number Customer Supplied Customer Supplied Customer Supplied FVZMARJ11 FVZRS485FC-1 FVZC1TPS FVZTERM
203
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
802.11G Interfaces
4 6 4 5 6 5 7 1. 2. 3. 4. 5. 6. 7. 8. Description 802.11G Transmitter/Receiver 802.11G Transmitter/Receiver 802.11G Receiver RS485 Jumper Cable Network Adapter RS485 Two Wire Cable Terminator RS485 Cable W/RJ45 Connector Part Number Customer Supplied Customer Supplied FVZRF802SS FVZRS485FC-1 FVZMARJ11 FVZC1TPS FVZTERM FVZRS485RJ45 FactoryVision Products And Messaging
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
204
Controller (Computer)
5 2
900MHZ Transceivers
1. 2. 3. 4. 5. 6. 7.
Description Transmitter Receiver Connector RS485 Jumper Cable Network Adapter RS485 Two Wire Cable Terminator
Part Number FVZRF900SS FVZRF900SS Comes with transmitter/receiver FVZRS485FC-1 FVZMARJ11 FVZC1TPS FVZTERM
Note: When using the Gigatron Protocol, Item # 1 MUST be Part Number _________.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
205
Factory Vision Marquee Series Users Manual Chapter 13- Connecting KEPWARE to Data Manager using DDE
To create a tag in Data Manager using a Kepware connection you must first open the logger on Data Manager.
Enter a name and description for the tag and select DDE for the Tag Type. The DDE address
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
206
Click on the DDE Tab and make sure that Enable DDE connections to the server is checked. Also this is where the Service name is located. By default the name is kepdde, but you can change it if you choose. Click OK when finished.
Locate one of the tags in Kepware that is required on the Data Manager Software. In this example, the tag Channel1.Device1.Tag1 will be used.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
207
The Tag will now be entered into the Data Manager software. On the DDE line enter: =kepdde|_ddedata!Channel1.Device1.Tag1 =<Server>|<Topic>!<Item> kepdde = is the service name from Kepware. _ddedata = is the default topic in the Kepware software. Channel1.Device1.Tag1 = is the tag you are displaying from Kepware. Select the Data Type and click OK to finish.
Click on the tag icon on the Data Manager toolbox and click anywhere on the display to insert the
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
208
Select the new tag from the tag list and click OK.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
209
If the tag address is red on the Multiple Tag Monitor display then something is not entered correctly. Go back to the tag definition screen and re-enter the DDE link until this address shows up in black and you see active data from the Kepware server.
When everything is correct there will be live data displayed on the Data Manager software.
Refer to the Data Manager section in our manual of the help files built into the Data Manager software for more information about setting up there tags on your display.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
210
Factory Vision Marquee Series Users Manual Chapter 14S, Stainless Steel Display Product Overview
The Factory Vision Display product line is divided into two groups; Marquee and Andon. The Marquee group consist of one to four line displays housed in an extruded aluminium cabinet. Components are accessed from either end of the display. The Andon group consist of five to eight line displays housed in a steel cabinet. Components are accessed from a front or back door that lifts up with the aid of pneumatic pistons. Chapters 1M through 4M offer Marquee information, Chapters 1A through 4A offer Andon information. Chapters 5 through 10 offer information common to both display types. This pictorial gives a brief description of the major parts of the Factory Vision Stainless Steel Marquee LED Display and tells you where to locate them on the unit.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
211
CAUTION!
The Display Board should be inspected for obvious shipping damage. Do not attempt to operate the unit if any damage is found.
Offloading
CAUTION! The crated Display Board is heavy. Qualified personnel using suitable lifting equipment, straps and supports must be deployed when offloading.
Unpacking
T P L GH Z R O P IN A A D
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
The Display Board is free standing within its transportation-packing crate. The crate is secured by nails and/or screws and therefore can be dismantled by means of simple hand tools. CAUTION! Due to the narrow construction of the Display Board it is unstable when left unsupported. Care should be taken when unpacking to ensure the unit is supported at all times.
Ground Handling
CAUTION!
Hazard - Crushing The Display Board is heavy: Up to 289 pounds depending on model. Suitable lifting equipment should be used when handling the unit.
T P L GH Z R O P IN A A D
DISPLAY IS HEAVY & MAY PRESENT A TOPPLING HAZARD
Hazard - Toppling Due to the narrow construction of the unit, the Display Board is unstable when left unsupported. It is suggested that the unit should only be removed from the packing case when a suitable method of support is available, i.e. chain block and straps. 212
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
Factory Vision Marquee Series Users Manual Chapter 15S Stainless Steel Display Pre-Installation Set Up Guide
The FV Series process control boards (PCB) runs a Windows operating system. Some familiarity with the operating system being used is assumed in the set up and configuration of the display board.
Pre-installation check
1) Check documentation pack: a) Windows license b) pcAnywhere CD c) Application setup file CD 2) Set laptop or PC TCP/IP settings comparable to the displays default settings, rebooting as necessary. 3) Connect laptop or PC to RJ45 connector on top of display either directly using a crossover lead or via hub using a standard patch lead. 4) Apply power and wait for display to boot up and display template, approximately 3-4mins. Note: It is important that the network cable is connected prior to powering the display. 5) Make remote connection to display using either pcAnywhere or NetMeeting - see following table for user name and password 6) Change display PCs name as required. Note: A reboot is required for the change to be effective; this will be done later. 7) Change display TCP/IP settings as required. Refer to Chapter 8 first section. Note: On Windows2000 and WindowsXP TCP/IP address changes are effective immediately and the connection will be lost. Reconfigure your laptop/PC comparable to the displays new TCP/IP address, rebooting if necessary. Re-establish the remote connection to complete the displays network configuration. 8) Reboot the display to ensure correct configuration. (Optional) 9) Shut down windows. The display is now ready for installation.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
213
Windows user level, user and password are shown in the table below. Note: Passwords are case sensitive. XPE has been configured as a single user system. User level Default Settings User name Administrator Administrator Administrator vs4000 Password Windows 2000 admin vs4000 Customer settings User name Password
IMPORTANT NOTE: Proper Windows shutdown must be performed prior to any movement or shipping of display or warranty will be voided. Improper Shutdown prior to movement may damage hard drive. The display is now ready for installation.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
214
Factory Vision Marquee Series Users Manual Pre Installation Set Up Objectives for non-PC Version Displays
For non internal PC displays that will be communicating via ethernet, it is recommended that the Gigatrons ethernet IP addressing is established before the display is suspended from the ceiling to help avoid network address conflicts. Review relevant safety and handling procedures as detailed in the safety instructions. Pre-Installation Check List: 1) Apply power to the display. 2) Observe the power-up screens and write down the number to determine the sign operating protocol loaded into the unit. If the number sequence is 3XXXX Go to Chapter Nine section Gigatron Native Protocol for set up and programming via ethernet. 4XXXX Go to Chapter Nine section Serial Communications Protocol for set up and programming via ethernet. 5XXXX Go to Chapter Nine section Adaptive Reduced Version Protocol for set up and programming via ethernet. 3) Wait approximately one to two minutes for display to complete power-up sequence.
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
215
Factory Vision Marquee Series Users Manual Chapter 16S Stainless Steel Display Installation
Ground Handling
Before handling, testing or installing the Display Board, familiarize yourself with Chapter 14A of this manual Offloading & Handling. There are a variety of safety issues, which need to be understood and complied with to ensure the safety of you, the Display Board and other people in the vicinity.
Mechanical Installation:
The Display Board should be installed wall-mounted from the six wall-mounting tabs attached to the unit.
CAUTION!
Wall being mounted to must be able to support the weight of the display.
CAUTION!
Care should be taken to ensure mounting bolts are suitably rated to carry the quoted weight and are correctly secured to the unit.
Installation
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
216
Display Size
A (inches ) 31.12
B (inches ) 27.00
Weight (pounds)
FV403C
8.50
165
3.1
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
217
Gigatron Board
PC Hard drive cable from PC to drive located under the Gigatron Board
PC Board
B Side video output connector from Gigatron to LED Distribution Board on B side of Display
RS232 used to feed an optional 2nd Gigatron PS2 port for Mouse and/or Keyboard
A Side video output connector from Gigatron to LED Distribution Board on A side of Display
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
218
5 Volt Power
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
219
Copyright 2005 Electro-Matic Products, Inc. All rights reserved. WI-0309 Rev.3 2/17/06
220