Installation

Transcoding and Rate Adaption Unit IMN:TRAU


A30808-X3247-M460-3-7631

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Important Notice on Product Safety


DANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS. The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system must comply with the applicable safety standards. Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components may also have high operating temperatures. Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage. Therefore, only trained and qualified personnel may install and maintain the system.

The same text in German: Wichtiger Hinweis zur Produktsicherheit LEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE. Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Alle an das System angeschlossenen Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen. In diesen Anlagen stehen die Netzversorgungsleitungen unter gefhrlicher Spannung. Einige Komponenten knnen auch eine hohe Betriebstemperatur aufweisen. Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Krperverletzungen oder Sachschden fhren. Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten.

Caution:
This equipment has been tested and found to comply with EN 301489. Its class of conformity is defined in table A30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the relevant standards referenced in the manual Guide to Documentation, may cause harmful interference to radio communications. For system installations it is strictly required to choose all installation sites according to national and local requirements concerning construction rules and static load capacities of buildings and roofs. For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagnetic field / force (EMF) limits. Otherwise harmful personal interference is possible.

Trademarks: All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

Copyright (C) Siemens AG 2006.


Issued by the Communications Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Reason for Update


Summary: Third Edition for Release BR 8.0 Details: Chapter / Section all Reason for Update Revised chapters

Issue History
Issue 1 2 3 Date of issue 01/2005 11/2005 03/2006 Reason for Update First Edition for New Release BR 8.0 Second Edition for Release BR 8.0 Third Edition for Release BR 8.0

A30808-X3247-M460-3-7631

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

This document consists of a total of 145 pages. All pages are issue 3.

Contents
1 1.1 1.2 1.3 1.4 1.4.1 1.4.2 1.5 1.6 1.7 2 2.1 2.2 2.3 2.4 2.4.1 2.4.2 2.5 2.5.1 2.5.2 2.5.2.1 2.5.3 2.6 2.6.1 2.6.2 3 3.1 3.2 3.3 3.4 4 4.1 4.1.1 4.1.2 4.2 4.2.1 4.2.2 4.3 4.3.1 4.3.2 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Position in the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Station Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 TRAU Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 TRAU-HC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Cable Length between Network Elements . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installation Activities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Disposal of Electrical and Electronic Equipment . . . . . . . . . . . . . . . . . . . . . 20 Mechanical Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Installation Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Equipment Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Equipment Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Rack Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Devices and Boards Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Installation of the TRAU-Standard Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Grounding connections of the TRAU Standard Rack (S30861-C21-X) . . . . 31 Grounding collector and fire protection kit for the TRAU-Standard rack (MK:FGV* - S30861-K106-X). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Fan units (FG Kit - S50201-U32-X) and rack door (FG kit - C50324-A201-B12) for fire resistance cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Earthquake Kit for the TRAU-Standard Rack. . . . . . . . . . . . . . . . . . . . . . . . 39 Installation of the TRAU-HC Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Earthquake Kit for TRAU-HC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Grounding connections for the TRAU-HC Rack. . . . . . . . . . . . . . . . . . . . . . 62 TRAU Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 TRAU Rack Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Primary Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 PCM and ALARM connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Asub/A interface connection of the TRAU Standard rack . . . . . . . . . . . . . . 69 Coaxial cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Balanced cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Alarms connection of the TRAU Standard rack . . . . . . . . . . . . . . . . . . . . . . 75 Remote Alarms connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Internal Alarms connection (W14, W15 connectors) . . . . . . . . . . . . . . . . . . 79 Asub/A interface connection of the TRAU-HC rack . . . . . . . . . . . . . . . . . . . 80 Coaxial cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Balanced cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4.4 4.4.1 5 5.1 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.3 5.3.1 5.3.2 6 7 8

Alarms connection of the TRAU-HC rack . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Remote Alarms connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 System Cabling of the TRAU rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 TRAU Standard rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 TRAU-HC rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Adapter Board cabling (M:ADAPTBTV1) . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Front-Panel Board cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Internal PCM lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Photographs of the wiring assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 TRAU HC Frame to mount in a TRAU Standard rack. . . . . . . . . . . . . . . . 126 Extra Adapter Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Replacement and expansion procedure . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Upgrade Procedure of a TRAU frame in a TRAU HC rack . . . . . . . . . . . . 134 Swap from TRAU Standard rack to TRAU HC rack . . . . . . . . . . . . . . . . . 144 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145

A30808-X3247-M460-3-7631

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Illustrations
Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 2.34 2.35 2.36 Position of the TRAU in the SBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Front view of the TRAU Standard rack . . . . . . . . . . . . . . . . . . . . . . . . . 13 Front view of the TRAU Standard rack in fire resistance cabinet . . . . . . 14 TRAU HC fully equipped. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 TRAU-HC frame with two TRAU modules and DC Panel. . . . . . . . . . . . 17 Interfaces between network elements . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Maximum attenuations between equipment and HF-DF rack . . . . . . . . . 19 Installation tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 TRAU rack unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Unpacking of TRAU devices and boards . . . . . . . . . . . . . . . . . . . . . . . . 25 TRAU rack installation accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 TRAU rack details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Rack fixing on concrete floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Rack fixing on raised floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Grounding kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Ground plate assy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Grounding cables kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Power cables connection for fans kit . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Fan units mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Flame-guard door mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Earthquake Kit : floor holes for the TRAU-Standard. . . . . . . . . . . . . . . . 40 Earthquake kit: front view.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Earthquake kit parts list. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Earthquake kit anchoring screws detail . . . . . . . . . . . . . . . . . . . . . . . . . 43 Earthquake kit: Internal Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 TRAU rack details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Minimum space necessary for a single TRAU rack installation . . . . . . . 47 Minimum space necessary for a back to back TRAU rack installation . . 48 Drilling sketch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Rack levelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Rack fixing on concrete floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Rack fixing on raised floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Back to back rack fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Earthquake kit installation: preliminary operations . . . . . . . . . . . . . . . . . 55 Earthquake kit: floor holes for TRAU-HC. . . . . . . . . . . . . . . . . . . . . . . . . 56 Earthquake kit: front view.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Earthquake kit: part list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Eathquake kit: Internal Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Anchor Kit S30861-K126-X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Anchoring screw S30861-K126 assembled on M12/50 anchor . . . . . . . 60 Fastening of the HSL M12/50 anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Rack fixed on the floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 RCAP of the TRAU rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig.

3.1 3.2 4.1 4.2 4.3 4.4 4.5 4.6 4.7 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 5.16 5.17 5.18 5.19 5.20 5.21 5.22 5.23 5.24 5.25 5.26 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9

TRAU-Standard power IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TRAU-HC power IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 TRAU Standard top view : Rach Cabling Access Panel (RCAP). . . . . . 67 TRAU-HC top view : Rach Cabling Access Panel (RCAP) . . . . . . . . . . 68 Coax Adapter mounted on left side (GW6, LW6). . . . . . . . . . . . . . . . . . 71 Coax Adapter mounted on right side (AW6, DW6) . . . . . . . . . . . . . . . . 72 PCM line connections to MDF (to/from BSC and MSC) . . . . . . . . . . . . 74 Remote Alarm connection to terminal block . . . . . . . . . . . . . . . . . . . . . 78 Coax Adapter mounted on left and right side. . . . . . . . . . . . . . . . . . . . . 82 TRAU Rack - Top view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Rack left side and rack right top side . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Power and ground cables distribution . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Interconnections list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 TRAU Sub-rack: front view (fuse panel shown in open position). . . . . . 95 TRAU sub-rack: Fuse Panel Mounting and Cabling . . . . . . . . . . . . . . . 96 Adapter Board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Adapter Board layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Adapater Board system block diagram . . . . . . . . . . . . . . . . . . . . . . . . . 99 DC-PANEL system block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Remote Alarms cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 PCM lines connectors in DC-Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 PCM lines wirings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Table of the rack wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Rack wiring 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Rack wiring 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Rack wiring 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Rack wiring 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Table of the frame wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Frame wiring 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Frame wiring 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Mechanical layout of the Extra Adapter board . . . . . . . . . . . . . . . . . . . 129 Extra Adapter Board system block diagram. . . . . . . . . . . . . . . . . . . . . 130 New subrack of the TRAU_HC in TRAU_standard rack . . . . . . . . . . . 131 Examples of replacement and expansion procedures . . . . . . . . . . . . . 133 Examples of replacement and expansion procedures . . . . . . . . . . . . . 133 TRAU frame wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 TRAU FRAME mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 DC PANEL rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 TRAU FRAME cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Frame mechanics mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Ground cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 PCM and Signal cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 DC Panel mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140

A30808-X3247-M460-3-7631

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig.

6.10 6.11 6.12 6.13 6.14 6.15 7.1 7.2

Ground cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Power cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Remote Alarm cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Daisy chain and Signal cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 DC Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Standard rack drilling sketch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 HC rack drilling sketch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Tables
Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. Tab. 1.1 1.2 1.3 2.1 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.19 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 5.16 5.17 5.18 6.1 6.2 Board equipping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Coaxial cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Balanced cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Types of anchorage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Left TRAUs PCM lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Right TRAUs PCM lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 PCM Lines connector pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Pinning of the 75ohm PCM on Adapter board . . . . . . . . . . . . . . . . . . . . 72 Pinning of the PCM connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Left TRAUs Remote alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Right TRAUs Remote alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Layout of the pins of connector AW3/DW3/GW3/LW3 . . . . . . . . . . . . . 76 Pinning of the Remote Alarm cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Pin description of the connectors W14 and W15 . . . . . . . . . . . . . . . . . . 79 Left TRAUs PCM lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Right TRAUs PCM lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 PCM Lines connector pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Pinning of the 75ohm PCM on Adapter board . . . . . . . . . . . . . . . . . . . . 83 Pinning of the PCM connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Left TRAUs Remote alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Right TRAUs Remote alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Layout of the pins of connector AW0-AW7 . . . . . . . . . . . . . . . . . . . . . . 87 Pinning of the Remote Alarm cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Connectors position, type and function . . . . . . . . . . . . . . . . . . . . . . . . . 90 Table of the Fuse Panel cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 X25 connector of the Adapter Board . . . . . . . . . . . . . . . . . . . . . . . . . . 100 X23,X24 connectors of the Adapter Board . . . . . . . . . . . . . . . . . . . . . 101 X27 connector of the Adapter Board . . . . . . . . . . . . . . . . . . . . . . . . . . 102 X26 connector of the Adapter Board . . . . . . . . . . . . . . . . . . . . . . . . . . 103 X5,X6 connectors of the Adapter Board . . . . . . . . . . . . . . . . . . . . . . . 105 X1,X2 and X3,X4 connectors of the Adapter Board. . . . . . . . . . . . . . . 105 X7 to X22 connectors of the Adapter Board . . . . . . . . . . . . . . . . . . . . 106 X13,X14 connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 X15,X16 connectors of the Front Panel Board . . . . . . . . . . . . . . . . . . 110 X17 connectors of the Front Panel Board . . . . . . . . . . . . . . . . . . . . . . 111 X1/X12 connectors of the Front Panel Board . . . . . . . . . . . . . . . . . . . 113 PCM lines connector in the Frame backpanel and in the RCAP . . . . . 117 X3,X4 connectors of the Extra Adapter Board . . . . . . . . . . . . . . . . . . . 126 X5,X6 connectors of the Extra Adapter Board . . . . . . . . . . . . . . . . . . . 127 X1,X2 connectors of the Extra Adapter Board . . . . . . . . . . . . . . . . . . . 127 X7 connector of the Extra Adapter Board . . . . . . . . . . . . . . . . . . . . . . 128 List of Rack Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 List of Frame cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

A30808-X3247-M460-3-7631

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

1 General
i
The CE declaration of conformity for the product will be fulfilled if the setup and cabling is undertaken in accordance with the specification in the manual and the documentation listed there, such as mounting instructions, cable lists etc. Where necessary, account should be taken of project-specific documentation. Deviations from the specifications or independent changes during setup, such as use of cable types with lower screening values, for example, can lead to the CE requirements being violated. In such cases the CE declaration of conformity is invalidated and the responsibility passes to the person who has caused the deviations. The applicable technical standards and regulations are listed in the Terminology Guide to Documentation A30808-X3247-K-52-x-7635. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. For the US market the following note applies:- PCM ports are intended to be connected to a near-placed Listed CSU (Channel Service Unit) providing over voltage protection.

i i

i 1.1

Purpose of the Manual


This document provides the information required for the installation of the Transcoder and Rate Adaption Unit (TRAU), rack configurated for balanced or coaxial PCM lines. In accordance with the GSM requirements, a TRAU provides a PCM line interface to the Base Station Controller (BSC) and four PCM lines to the Mobile Switching Center (MSC) PCM line to/from BSC can be redundant.

1.2

Position in the System


The following figure gives the position of the TRAU within the BSS. Um Interface

BTS Mobile Station Abis Interface

BSC Asub Interface SBS

TRAU A Interface

MSC

Fig. 1.1

Position of the TRAU in the SBS

10

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

1.3

Site Requirements
Before starting the installation, the construction of the room in which the operation and maintenance equipment is to be housed must be complete and the room in good condition and dry heaters, if necessary, should be put up in the room. Doors and windows, if any, must already have been installed and must be lockable. Openings in wall or ceiling of oor, if required, must be complete. The oor covering must have been laid. Room lighting and wall sockets must have been installed. Heating or air-conditioning systems should be ready for operation. Walls and ceilings should have been painted. The room must be clean. To prevent subsequent accumulation of dust and dirt, the parts and equipment units to be installed must be unpacked outside the room (if possible). After that it is advantageous to install the OMS-B equipment, after all other installation works to create the required infrastructure (power supply, PCM30 lines ...) are complete.

1.4

Station Conguration
The TRAU functionality is mechanically arranged in two variants: - TRAU rack able to manage up to 480 TCH (Standard configuration) - TRAU-HC rack able to manage up to 960 TCH (High capacity configuration)

1.4.1

TRAU Standard
The TRAU Standard rack (S30861-C21-X), which is configured according to the ETSI standard (h=2000mm, l=600mm, p=300mm) (h=78.7,w=23.6,d=11.8) can accommodate up to 4 TRAU subracks equal each other and equipped with the same boards (files BC, EF, HI and MN). Every subrack includes a fuse and alarm panel (files A, D, G and L). Files A, D, G and L relate to the backplanes of the TRAU subracks with the connectors for internal and external connections. A lamp panel is equipped in file T. The sensor of the Open Door Alarm (OPDS) is equipped in file O. The TRAU rack includes up to 4 subrack (4 TRAU modules) The subrack (H=420mm (16.5), W=533mm (21), D=249mm (9.8) includes the interfaces to the BSC (BSCI) and the MSC (MSCI) , the transcoders (TRAC) and the cable connection zone to the RCAP of the rack. TRAU subrack capacity (depending on PCM line type): One PCM line with 120 or 96 16kbit/s channels to/from the BSC. Four PCM lines with 30 or 24 64kbit/s channels to/from the MSC. This capacity corresponds to 15 or 12 TRXs (full rate) located in the BTS (radio measures pre-processed in the BTS).

A30808-X3247-M460-3-7631

11

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Boards are equipped according to the following Tab. 1.1. Quantity 2 2 6 2 Tab. 1.1 Acronym BSCI MSCI TRAC PWRS Board equipping Slot position 40-44 36-48 18-24-30 52-58-64 3-71 1 1 2 Notes

Note 1: Boards in position 44 and 48 are for redundancy purposes. Note 2: All the TRAC boards of a TRAU subrack are always equipped at the factory, irrespective of the number of channels of the PCM line coming from the BSC. One board (out of the equipped six) is for redundancy purposes. The TRAU Fuse and Alarm Panel (TFAP) (H=116mm (4.6), W=533mm (21)), accommodates the fuses through which the primary power is brought to the equipment, the LEDs displaying the equipment alarms, and the SUB D 15 connector interfacing (V.11) the Local Maintenance Terminal (LMT). The rack is equipped with an alarm panel placed at the top of the rack which can be attained by removing the front cover. The racks have a door mounted. Therefore a new alarming mechanism is introduced detecting when the door is left Open (see detail x in Fig. 2.5). The relevant TRAU Open door alarm is managed by SW and treated as an internal alarm. A sensor is cableconnected to the first TRAU shelf of the rack, indicating when the TRAU door is Open. The TRAU rack configuration is modular in accordance with the number of the transcoders to be equipped. The number of the transcoders depends on the number of traffic channels coming from the BSC. Every TRAU subrack can be equipped with 5 (+1 redundant) transcoder boards (TRAC). Every TRAC board handles up to 24 traffic channels. Fig. 1.2 shows a picture of the TRAU Standard rack fully equipped and Fig. 1.3 with flame-guard door and fan units in file H.

12

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

BSC LINK ALARM

A
T R A C 3 T R A C 4 T R A C 5 P W R S 1
71

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

BC

30 36 40 44 48 52 58 64

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

BSC LINK ALARM

D
T R A C 3 T R A C 4 T R A C 5 P W R S 1
71

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

EF

30 36 40 44 48 52 58 64

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

G
T R A C 4 P W R S 1
71

BSC LINK ALARM

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

T R A C 3

T R A C 5

HI

30 36 40 44 48 52 58 64

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

L
P W R S 1
71

BSC LINK ALARM

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

T R A C 3

T R A C 4

T R A C 5

MN

30 36 40 44 48 52 58 64

O
OPDS

Fig. 1.2

Front view of the TRAU Standard rack

A30808-X3247-M460-3-7631

13

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

BSC LINK ALARM

A
T R A C 3 T R A C 4 T R A C 5 P W R S 1
71

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

BC

30 36 40 44 48 52 58 64

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

D
T R A C 3 T R A C 4 T R A C 5 P W R S 1
71

BSC LINK ALARM

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

EF

30 36 40 44 48 52 58 64

POWER 0 10A F POWER 1 10A F LOCAL TERMINAL

GLOBAL ALARMS CRITICALMAJOR MINOR

LAMP TEST

G
T R A C 4 T R A C 5 P W R S 1
71

BSC LINK ALARM

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

T R A C 3

HI

30 36 40 44 48 52 58 64
POWER 0 GLOBAL ALARMS CRITICALMAJOR MINOR LAMP TEST

10A F POWER 1 10A F LOCAL TERMINAL

BSC LINK ALARM

L
T R A C 3 T R A C 4 T R A C 5 P W R S 1
71

P W R S 0
3

T R A C 0
18

T R A C 1
24

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

MN

30 36 40 44 48 52 58 64

OPDS

Fig. 1.3

Front view of the TRAU Standard rack in fire resistance cabinet

14

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

1.4.2

TRAU-HC
The new TRAU-HC (S30861-C37/C41-X) rack has the same footprint as that the previous TRAU Standard rack, mechanical dimensions h=2000, l=600, p=300 (h=78.7, w=23.6, d=11.8) , but each rack includes up to 4 Frames (8 TRAUs) (Fig. 1.5). Fans are included for heat dissipation (Fig. 1.4). No power supply card is necessary because all the cards have a DC/DC converter on board. The weight, fully equipped, is 130 Kg (286 lb). The rack is equipped with an alarm panel placed at the top of the rack which can be attained by removing the front cover The racks have a door mounted. Therefore a new alarming mechanism is introduced detecting when the door is left Open (see detail x in Fig. 2.19). The relevant TRAU Open door alarm is managed by SW and treated as an internal alarm. A sensor is cable-connected to the first TRAU shelf of the rack, indicating when the TRAU door is Open. The new TRAU frame can be mounted on the old rack by using the Extra Adapter Board (S30861-U725-X) mounted into the DC-Panel. In that case, as the RCAP board is the same as that of the Standard configuration, the number of channels cannot exeed 480 TCH. The TRAU rack configuration is modular in accordance with the number of the transcoders to be equipped. The number of the transcoders depends on the number of traffic channels coming from the BSC. Each TRAU module is functionally independent from the other ones and can be equipped with 5 (+1 redundant) transcoder boards (TRAC). Every TRAC board handles up to 24 traffic channels. Fig. 1.4 shows a picture of the TRAU HC fully equipped. Leds, lamps, signallings and alarms reporting have the same philosophy as that of the Standard configuration (Fig. 1.4 and Fig. 1.5) except for the Fan-alarm and Door-open alarms. The Fan-alarm is reported on the TRAU_Right (odd numbered) and the Dooropen-alarm on the TRAU_Left (even numbered). So to manage both the alarms, the presence of two TRAUs at least, within the same subrack, is necessary. .

A30808-X3247-M460-3-7631

15

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

TRAU 0

TRAU 1

TRAU 2

TRAU 3

TRAU 4

TRAU 5

TRAU 6

TRAU 7

Fig. 1.4

TRAU HC fully equipped

16

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

DC Panel

TRAU module Fig. 1.5 TRAU-HC frame with two TRAU modules and DC Panel.

A30808-X3247-M460-3-7631

17

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

1.5

Cable Length between Network Elements


Fig. 1.6 shows A, Abis and Asub interfaces; whereas, Tab. 1.2, Tab. 1.3, and Fig. 1.6 show the maximum distances and attenuations allowed between BSS racks (BTS, BSC, TRAU) and between the BSS (TRAU) and the MSC.

Abis

BTS

BSC

Asub BSS Fig. 1.6

TRAU

MSC

Interfaces between network elements

For the US market PCM ports are intended to be connected to a near-placed Listed CSU (Channel Service Unit) providing over voltage protection.

Coaxial Version Connection A Asub Abis Tab. 1.2 Max. hop attenuation 6 dB 6 dB 6 dB Coaxial cables Max. hop length cable attenuation dependent cable attenuation dependent cable attenuation dependent

Balanced Version Connection A Asub Abis Tab. 1.3 Max. hop attenuation 6 dB 6 dB 6 dB Balanced cables Max. hop length cable attenuation dependent cable attenuation dependent cable attenuation dependent

Whenever two equipment elements are connected through High Frequency-Distribution Frames (HF-DF), the maximum attenuation is as follows:

18

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

1st equipment HF-DF 2nd equipment HF-DF

6 dB 6 dB

BSC

6dB

HF-DF

TRAU

6dB

HF-DF

Fig. 1.7

Maximum attenuations between equipment and HF-DF rack

1.6

Installation Activities
The installation activities for the BSS-TRAU rack consist of the following: Unpacking the rack and inspecting for visible damages Positioning the rack as per oor plan and anchoring it to the oor Grounding the rack Connecting DC power to the rack Note: The recommended torque value for the screws of the input terminal block is from 1.24 to 2.26 N x m (11 to 20 lb x in). Connecting external cables Inserting power supply boards and disk units into the rack.

A30808-X3247-M460-3-7631

19

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

1.7

Disposal of Electrical and Electronic Equipment

All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your sales representative. The statements quoted above are only fully valid for equipment which is installed in the countries of the European Union and is covered by the directive 2002/96/EC. Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment.

20

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2 Mechanical Installation
2.1 Installation Tools
The correct rack installation is carried out with the aid of the following tools (see Fig. 2.1). Hammer drill (ATF) Twist drills widia 20mm (0.79) and 9mm (0.35) (PRP) Poligonal socket wrench (CHT) Poligonal wrench (CHP) N3 and N4 screwdrivers (CAT) for cross-slotted screws N2, N3 and N4 screwdrivers (CA) Square (SQ) Plumb line (FP) Tracer (TR) Screwdrivers for M3, M6 and M12 hex.socket head screws (CHB) Electric jigsaw with sawdust vacuum and lter (for raised oors only) (ATS) Other tools are needed for the electrical connections: Wire-wrap tool for 0.8 x 1.2mm (0.03x0.05)anchoring pins and 0.5mm (0.02) wire Power soldering iron for tinned copper braid welding Soldering iron for electronic circuits Crimping tool

A30808-X3247-M460-3-7631

21

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 2.1

Installation tools

22

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.2

Equipment Delivery
Racks, devices, boards, cables as well as all installation material and relevant manuals are shipped in cartons or in wood boxes. Handle each container with extreme caution to avoid tipping. All boxes containing installation material have the following information printed on them or indicated in label W of Fig. 2.2 and Fig. 2.3: trade-mark customer order number serial number of rack or other equipment destination gross and net weight overall dimensions symbol or inprint to identify the "Top" or "Bottom" For transport of the cartons from the unloading area into the construction room use handling aids (for example: fork-lift truck, goods elevator); a second person is needed for help.

2.3

Preliminary Checks
Check that the cartons are not damaged. In case of evident damage due to transport, unpack the equipment in the presence of an insurance company representative and promptly claim any damage and inform the shipper for specifying the damage. Check whether the package is actually addressed to the site and complete. Open it and take the contents out carefully. After having removed all contents from the packing material, check for deformation to the devices, of torn or unwelded wiring, of oxidized connectors, as well as deformed front sides of the units, loose screws, damage to paint work, etc.

2.4

Equipment Unpacking
During the unpacking steps great care must be taken to ensure that the equipment is not scratched or damaged in any way. The packing material should be preserved for possible future re-packing. In case of repacking or in the event that repacking material is supplied by the customer, special care should be taken to avoid damage during the transport and storage of the devices.

A30808-X3247-M460-3-7631

23

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

9 8

2
FRA GILE

3 Fig. 2.2 TRAU rack unpacking

24

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Z W

3 Z1

Z2

Fig. 2.3

Unpacking of TRAU devices and boards

A30808-X3247-M460-3-7631

25

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

2.4.1

Rack Unpacking
With reference to Fig. 2.2 proceed as follows: Cut the straps 8 and 9 and remove the container cover 7. Take out the rack from the box 1 and the relevant wood support 2. Open the tubular shrink-wrap 5 protecting the rack and take it out. Remove the 8 dehydrating material bags 6 xed with adhesive tape. Remove the protections 3 of rack head and base and lift the rack to vertical position. Remove the 2 front proles 4 and the 2 rear proles 4 protecting the rack edges.

2.4.2

Devices and Boards Unpacking


With reference to Fig. 2.3 proceed as follows: Cut with a suitable knife the adhesive tape sealing the box 1. Take the device out. Remove the shaped proles in polystyrene foam 4. Remove the dehydrating material bags 3. Open the wrap 2 protecting the device/board and withdraw it. The packing material should be preserved for possible future repacking. To this purpose, reverse the procedure described above, taking into account the warnings specified for the packing. In case of repacking or in the event that repacking material is supplied by the Customer, special care should be taken to avoid damages during transport and storage of the devices.

26

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.5

Installation of the TRAU-Standard Rack


The TRAU rack is provided with proper metal eyebolts (G1 G4) for securing the rack during transport (see Fig. 2.5). The aluminium protection grid, in the upper part of subracks, is covered during transport and installation by a fender sheet which is to be removed after installation and which prevents damages caused by accidental falls of screws or other installation tools. The Y detail shows the ESD jack (CNB) for wrist (BR) strap connection. The rack can be anchored onto two types of floor (see Tab. 2.1 as well as Fig. 2.6 and Fig. 2.7): Type of anchorage Wall anchorage Stand alone rack Back to back racks Tab. 2.1 yes yes yes Standard oor (concrete) yes yes yes Raised oor

Types of anchorage

Note: The stand alone rack anchored on raised floor must be also fixed to the wall. The installation of the TRAU requires the following accessories, available separately (see Fig. 2.4): Adaption (AD): Expansion bolts (M8): for securing the rack to the wall for fixing the rack to the wall

90 (3.5

70 (2.8

AD M8 6 (0.2)

Fig. 2.4

TRAU rack installation accessories

A30808-X3247-M460-3-7631

27

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

.For correct positioning of the rack, trace the drilling plan of the floor, whichever this is, using the plumb line, the square and the tracer. These procedures, relevant to the rack installation, adjustment and alignment, are valid for all types of rack configurations. Make sure the leveling feet (P1-P4) of the rack basement do not stretch out the basement level. Place the rack in vertical position, then make the reference pins of the alignment bar, to be aligned with the corresponding holes in the rack basement. Make sure the alignment bar is fully inside the groove of the rack basement. Remove the flame guard hex.socket head screws, M12, and washers from the hole for the expansion bolt M8. Put the rack in a vertical position so that the holes on the floor coincide with the holes of the rack basement. Adjust the leveling feet (P1-P4) of the basement to have the rack coinciding both vertically and horizontally in the correct position. Screw tightly the hexagonal bolts (M8x10) of the upper anchorage, then the hexagonal expansion bolts (2xM8x25) of the floor by means of a 13mm (0.5) socket wrench. For elevated floor, use proper (2x5x30 Din 97/UNI 702) self-thread screws and tighten them firmly.

28

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Y detail

ESD jack for wrist strap connection

TRAU Open Door

Fig. 2.5

TRAU rack details

A30808-X3247-M460-3-7631

29

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 2.6

Rack fixing on concrete floor

Fig. 2.7

Rack fixing on raised floor

30

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.5.1

Grounding connections of the TRAU Standard Rack (S30861-C21-X)


The rack has to be connected to the site specific ground system before to starting the connection of the power cable. To grounding the rack has to be used the Grounding kit (Fig. 2.8 ).

The Grounding kit (C50324-A201-A6) is part of the Fire Resistance kit. The kit contains the following items: 1. 2. 3. 4. 5. ground plate assy (see Fig. 2.10) grounding cables grounding label bush cover (see Fig. 2.10, pos. 10)

(0.39+/-0.06)

10+/-1.5

25+/-1.5 (0.98+/-0.06)

Fig. 2.8

Grounding kit

The ground plate assy (see Fig. 2.10) contains the following items: 1. 2. 3. 4. 5. ground plate washer contact washer hexagon nut screw

A30808-X3247-M460-3-7631

31

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

77.5 (3.05)

Fig. 2.9

Ground plate assy

Mounting instruction of the grounding kit (see Fig. 2.10): Remove the grounding cable (if it is connected) from the RGB bolt (corresponding to pos. 2)) on the top of the rack. Remove yellow ground label 4) Remove ground connection nut 2), washers and the screws 3). Place as shown the ground plate 1) and replace nut and washer 2). Change the screws 3) with the one supplied in the kit (item 5 of Ground plate assy). Spacing piece 11) supplied with ground plate kit should be used if it is necessary only to guarantee a correct plate mounting. The ground plate should be parallel to the rack top plate. Remove screws 6) and connection cover 5). Cut label in half and cover the two ground symbol of the ground terminal block as shown 12). Place ground cables 7) and 8) supplied by the kit and connect them as shown. Lock ground cables by the cable tie 9). Place the new connection cover 10) and x it by the screws previously removed.

32

A30808-X3247-M460-3-7631

46.5 (1.83)

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Grounding kit installation

Two bolts for external ground wire connection

Fig. 2.10

Grounding cables kit To grounding the rack use a 16mmq/5AWG or 25mmq/3AWG PVC Ye/Gr copper wire. The connection should be connected to a main wire or to a ground bar on the shortest way. Mounting procedure of the external ground wire: Use the nearest ground system on site. Verify the distance between the connection points of the ground system and the ground bolts of the rack. Cut the wires to the required length. Unsheet the wire at the end and crimp a two-hole M6 lug terminal (i.e. Thomas & Betts type 54852BE blue color for 16mmq/6AWG or 54856BE brown color for 25mmq/3AWG). Remove hexagon nut 4), contact washer 3) and washer 2) of the ground plate assy. Connect the prepared wire to the ground plate assy by a two-hole lug terminal. Replace the hexagon nut 4), contact washer 3) and washer 2). Tighten the hexagon nut rmly.

A30808-X3247-M460-3-7631

33

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

2.5.2

Grounding collector and fire protection kit for the TRAU-Standard rack (MK:FGV* - S30861-K106-X)
The FIREPROT-0 (MK:FG) is an optional kit reducing the damage of a fire on the TRAU rack (S30861-C21-X) and also includes an additional extension of the rack grounding. Unit part number list: Grounding kit (C50324-A201-A6). Fun unit (S50201-U32-X). FGV1 rack door (C50324-A201-B12). Four cable tie (H70764-B140-J210). One label (C7322-R6-N1).

34

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.5.2.1

Fan units (FG Kit - S50201-U32-X) and rack door (FG kit - C50324A201-B12) for fire resistance cabinet.
This kit is available only for S30861-C21-X TRAU-Standard rack. The fan units kit consists of : Fan motor assembly Two power supply cables Mounting instruction with reference to Fig. 2.11 : Remove grid cover 1) by the screws. Remove nuts 3) and connect fan units power supply cables 4) and 5). Cables lug to be connected on the existing ones. Lock cables by the previously removed nuts 3). With reference to Fig. 2.12: Connect power supply cables 4) and 5) coming from Bus Bar PP0 as shown. Cables must be xed to the fan unit front panel as shown by cable ties 7) supplied with the kit. Insert fan units 6) in the rack and t it by grid cover screws 2) previously removed. Place the cables in the left rack space (side of the sub-racks). With reference to Fig. 2.13 Remove door xing screws 1) and disconnect door ground cable from door side. Place new door and connect the door ground cable previously disconnected and x the door by the removed screws 1). Place the label 20) in indicated position.

A30808-X3247-M460-3-7631

35

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

2)
T H
POWER 0 10A F POWER 1 10A F LOCAL TERMINAL GLOBAL ALARMS CRITICALMAJOR MINOR LAMP TEST

BSC LINK ALARM

A
T R A C 3

P W R S 0
3

T R A C 0

T R A C 1

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

T T R R A A C C 4 5

P W R S 1
71

BC

18 24

30 36 40 44 48 52 58 64

Fig. 2.11

Power cables connection for fans kit

36

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2)

6)
T H A
POWER 0 10A F POWER 1 10A F LOCAL TERMINAL GLOBAL ALARMS CRITICALMAJOR MINOR LAMP TEST

BSC LINK ALARM

P W R S 0
3

T R A C 0

T R A C 1

T R A C 2

M S C I 0

B S C I 0

B S C I 1

M S C I 1

T R A C 3

T T R R A A C C 4 5

P W R S 1
71

BC

18 24

30 36 40 44 48 52 58 64

5) BLUE FROM BUS BAR PP0 -V

5) 7)

4) BLACK FROM BUS BAR PP0 +V

FANS EXISTING CABLE

4)

5) FANS EXISTING CABLE

Fig. 2.12

Fan units mounting

A30808-X3247-M460-3-7631

37

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 2.13

Flame-guard door mounting

38

A30808-X3247-M460-3-7631

EXISTING LABELS

FGV1 2D-CODE LABEL

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.5.3

Earthquake Kit for the TRAU-Standard Rack.


Earthquake Kit, available separately, allows the TRAU rack to be resistant to earthquake zone 4 strains, according to the NEBS requirements.

This kit is available only for S30861-C21-X rack starting from issue 06 on. The kit for TRAU-Standard (MK: EQ4V1 - S30861-K105-X) consists of (Fig. 2.16): 1. 2. 3. 4. N2 Internal Plate (C50324-A201-C13) N4 Anchoring Screws (HSL M12/50)(C50117-A201-B49) N1 Label (C7322-R6-N1) N1 Insulating plate (C50117-A201-C389)

i
!

The Earthquake Kit allows the TRAU rack to conform with the Bellcore specification and is mandatory for the U.S. market. The concrete floor shall have the compressive strength of 30 N/mm2 minimum With reference to Fig. 2.14, Fig. 2.15 and Fig. 2.16 proceed as follows: 1. Mark oor holes. 2. Drill a 90mm (3.54) deep hole (18 mm (0.71) diameter hole) for each Anchoring screw. 3. Using an appropriate vacuum, clear the hole with a small diameter hose which can reach the bottom of the hole. 4. Take off the leveling feet (P1-P4 in Fig. 2.6 and Fig. 2.7) from the rack basement and, if necessary, extend the hole size to 20 mm (0.79) diameter. 5. Place the TRAU rack. The hole of the rack basement must t the hole on the oor. 6. Position the Internal Plates over the holes. Be careful not to let any debris fall into the holes. 7. Insert the anchor into the hole and tap the anchor down with a hammer until the washer contacts the rack internal plate. 8. Screw down the Anchor HSL M12/50 having 80Nm tightening torque.

A30808-X3247-M460-3-7631

39

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

1+1 INTERNAL PLATE

N4 EXAGONAL-HEAD SCREW (HSL M12/50) FOR ANCHORAGE

TRAU CABINET

TRAU POSITION
16 (6. 0 3)

300 (11 .8 )
95 (3. 7)

HOLES FROM LODGING FLOOR

0 30 .8) (11 0 60 .6) (23 0 15 ) 9 (5.

Fig. 2.14

Earthquake Kit : floor holes for the TRAU-Standard.

40

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

N4 GOLFARE FOR LIFT THE CABINET

INTERNAL PLATE HSL M12/50 WASHER

18 (0.71)
84 (3.3)
18 (0.71)
FLOOR

18+1

90 (3.5)
Fig. 2.15 Earthquake kit: front view. A30808-X3247-M460-3-7631

162 (6.37)

41

(41 3)

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 2.16

Earthquake kit parts list.

42

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 2.17

Earthquake kit anchoring screws detail

A30808-X3247-M460-3-7631

43

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

145 mm (5.7)

160 mm (6.3)

21 mm (0.83)

Fig. 2.18

Earthquake kit: Internal Plate

37,5 mm (1.5)

275 mm (10.8)

44

A30808-X3247-M460-3-7631

220 mm (8.7)

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.6

Installation of the TRAU-HC Rack


The TRAU rack is provided with two proper metal eyebolts (G1 and G2) on the top for securing the rack during the transport (see Fig. 2.19.).

If the rack is provided with the earthquake kit take care of the floor flatness/ruoghness. The floor flatness tolerance must be 6mm/mq max. and the roughness tolerance 5 mm max

BR G1 G2

CNB

Detail Y

Fig. 2.19

TRAU rack details

A30808-X3247-M460-3-7631

45

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

The Y detail shows the ESD jack (CNB) for wrist (BR) strap connection. The rack can be anchored on the concrete floor or raised floor in stand alone or back to back mode (see Fig. 2.23). Before starting of rack installation, consult the site documentation to locate the installation point of the TRAU rack, the PCM network termination, the Alarm connection point, the Power Supply unit; then check the grounding bar and the necessary cable runways.

46

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Minimum room height

2250mm (88.6)

2000mm (78.7)

Front

300 mm (11.8)

Minimum 100mm (3.9)

600mm (23.6) 950mm (37.4)

Front

700mm (27.6) Fig. 2.20 Minimum space necessary for a single TRAU rack installation

A30808-X3247-M460-3-7631

47

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Minimum room height

2250mm (88.6)

2000mm (78.7)

Front

Front

600mm (23.6)

300 mm (11.8) Minimum 100mm (3.9) 1900mm (74.8)


950mm (37.4)

600mm (23.6)

Front

Front

Minimum 800mm (31.5) Fig. 2.21 Minimum space necessary for a back to back TRAU rack installation

48

A30808-X3247-M460-3-7631

1500mm (59)

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Installation on concrete floor: Mark the positions of the drilling holes as per Fig. 2.22. Drill the oor with 18mm in diameter and a depth of 90mm. Clean out the drilling holes by vacuuming. Make sure the levelling feet (P1-P4 - see Fig. 2.23) of the rack basement do not stretch out the basement level. Place the rack in vertical position and shift it in the correct position so that the holes on the floor coincide with the holes of the rack basement. Adjust the levelling feet (P1-P4 - see Fig. 2.23) of the basement to have the rack coinciding both vertically and horizontally in the correct position. Insert (see Fig. 2.24) the anchor (e.g. HILTI HSL M12/25) and washer (e.g. DIN 125 - Internal Diameter=21mm - External Diameter=37mm) into the hole and tap the anchor down with a hammer until the washer contacts the rack basement. Screw down the anchor HSL M12/50 having 80Nm tightening torque.

45 (1.77)

BASEMENT LAYOUT 300+/-0.25 (11.8+/-0.01)

57 (2.2)

145+/-0.25 (5.7+/-0.01)

transportation holes

adjustable feet

599+/-1 (23.6+/-0.04)

Fig. 2.22

Drilling sketch

300+0-1.5 (11.8+0-0.01)

80 (3.15)

A30808-X3247-M460-3-7631

49

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 2.23

Rack levelling

Washer

Anchor

Fig. 2.24

Rack fixing on concrete floor

50

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Installation on raised floor: Mark the positions of the drilling holes as per Fig. 2.22. Drill the raised oor with 18mm in diameter Drill the concrete oor with 18mm in diameter and a depth of 90mm. Clean out the drilling holes by blowing or sucking. Make sure the levelling feet (P1-P4 - see Fig. 2.23) of the rack basement do not stretch out the basement level. Place the rack in vertical position and shift it in the correct position so that the holes on the floor coincide with the holes of the rack basement. Adjust the levelling feet (P1-P4 - see Fig. 2.23) of the basement to have the rack coinciding both vertically and horizontally in the correct position. Insert (see Fig. 2.25) the anchor (e.g. HILTI HSA M12/80+300) and washer (e.g. DIN 125 - Internal Diameter=17mm - External Diameter=30mm) into the hole and tap the anchor down with a hammer until the washer contacts the rack basement. Screw down the Anchor HSL M12/80+300 having 50Nm tightening torque.

(Di=0.67 De=1.18)

(3.5)

(D=0.71)

Fig. 2.25

Rack fixing on raised floor

If the distance between the raised and the concrete floor (Ground floor loose stone foundation) is bigger than the length of the screw of the anchor (e.g. HILTI M12/300) replace the screw of the anchor with a threaded rod M12 DIN 975 cutting the same at the right leght.

A30808-X3247-M460-3-7631

51

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Racks installed back to back If two rack are installed back to back it also needs to fix the racks on the top. After having installed the racks proceed as follows (see Fig. 2.26): Take the plane washer (dameter 10.5 DIN 934) in the correct position. Insert the bolt (M10 DIN 933). Insert the spring washer (diameter 10.5 DIN 127). Tighten the nut (M10 DIN 934) rmly.

Nut M10 DIN 934

Spring washer diam.10.5 DIN 127 Plane washer Diam.10.5 DIN 433
Bolt M10 DIN 933

Fig. 2.26

Back to back rack fixing

52

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

2.6.1

Earthquake Kit for TRAU-HC.


Earthquake Kit, available separately, allows the TRAU rack to be resistant to earthquake zone 4 strains, according to NEBS requirements.

! !

The floor flatness tolerance must be 6mm/mq max. and the roughness tolerance 5 mm max The concrete floor shall have the compressive strength of 30 N/mm2 minimum The kit for TRAU-HC (MK: EQ4V2 - S30861-K121-X) consists of (Fig. 2.30): 1. 2. 3. 4. 5. 6. N2 Internal Plate (C50324-A201-C39) N4 Anchoring Screws (V50089-B3-P100) N1 Label (C7322-R6-N1) N4 washers (C50324-A201-C40) N1 Insulating bushes (C50324-A201-C41 N1 Insulating plate (C50324-A201-C42)

For installed TRAU-HC pull out the cards of the down rack and take out the four guiderails on the right side and the four guide-rails on the left side

Mounting Instructions
With reference to Fig. 2.27 Fig. 2.28, Fig. 2.29 and proceed as follow: 1. Pull out the cards of the down rack if they are inserted and take out the three guiderails on the right side and the two guide-rails on the left side (mark their slot position, so it is easier to reassemble them) 2. Mark oor holes (if the new rack replaces the old standard type you can use the previous holes by two anchoring screws S30861-K126-X kit (see mounting instruction below). 3. Drill a 105mm (4.13) deep hole (18 mm (0.71) diameter hole) for each anchoring screw. 4. Using an appropriate vacuum, clear the hole with a small diameter hose which can reach the bottom of the hole. 5. Take off the leveling feet (P1-P4 in Fig. 2.23) from the rack basement and, if necessary, extend the hole size to 20 mm (0.79) diameter. 6. Place the insulating plate and the TRAU rack on. The hole of the rack basement must t the hole on the oor. 7. Position the Internal Plates over the holes. Be careful not to let any debris fall into the holes. 8. Insert the anchors into the holes and tap the anchors down with a hammer until the washer contacts the rack internal plate. 9. Insert on the anchors the insulating bush, thei nsulating washer, the washer, and screw down the Anchor HSL M12/50 having 80Nm tightening torque.

A30808-X3247-M460-3-7631

53

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Mounting Instructions using the Kit S30861-K126-X.


The kit S30861-K126-X is an optional kit to fix the BT 960 HC rack on the holes of the previous TRAU rack (S30861-C20-X). It s consist of (refer Fig. 2.32): Nr.2 complete rod (item1) Nr.2 ring (item 2) Nr.2 insulating bush (item 3) Nr.4 washer (item 4) Nr.2 Xexagon nut M12 (item 5) Nr.1 label

With reference to Fig. 2.33 proceed as follows: 1. Insert the washer (item 2) on long threaded part of item 1 and the ring ( item 3) . Then insert, removed from HILTI HSL-B-TZ M12/50 anchor SIEMENS code V50089-B3-P100-7625 supplied with the kit S30861-K121-X the S30861-K121-X kit, the rubbing (item 4), the expansion cone (item 5) and screw the nut cone (item 6) 2. Insert the insulating bush (item 3) on opposite threaded part, insert the washer (item 4) and screw in the nut (item 5) 3. Position the Internal Plates, from S30861-K105-X kit, over the holes. Be careful not to let any debris fall into the holes andPut the two anchor so assembled in the holes 4. Insert the two so assembled anchor into the rear position hole and tap the anchor down with a hammer until the washer contacts the rack internal plate. 5. Screw down the anchor HSL M12/50 having 80Nm tightening torque with the M12 pivot frontal direction (Fig. 2.34 6. Place the TRAU rack on. The anchor must t the rear holes of the rack basement and the front holes of the rack basement must t the holes on the oor. 7. Position the Internal Plates over the rack basement. Be careful not to let any debris fall into the holes. 8. Mount the anchor V50089-B3-P100-7625 supplied with the S30861-K121-X kit on the front holes. 9. Insert on the rear anchors the insulating bush, the nsulating washer, the washer, and screw, by using a dynamometer at 80 Nm, the nut M12/50. (Fig. 2.35).

After the installation stick 20 code label on rack door in reserved area

54

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 2.27

Earthquake kit installation: preliminary operations

A30808-X3247-M460-3-7631

55

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

1+1 INTERNAL PLATE

N4 EXAGONAL-HEAD SCREW (HSL M12/50) FOR ANCHORAGE

TRAU CABINET

TRAU POSITION

(5. 145 71 )

(10 271 .67 )


(2. 67.5 66 )

HOLES FROM LODGING FLOOR

0 30 .8) (11 0 60 .6) (23 0 15 ) 9 (5.

Fig. 2.28

Earthquake kit: floor holes for TRAU-HC.

56

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

N2 GOLFARE FOR LIFT THE CABINET

INTERNAL PLATE HSL M12/50 WASHER

18 (0.71)
84 (3.3)
18 (0.71)
FLOOR

18+1
105 (4.1)

Fig. 2.29

Earthquake kit: front view.

A30808-X3247-M460-3-7631

162 (6.37)

57

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 2.30

Earthquake kit: part list

58

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

145 mm (5.7) 23 mm (0.91)

145 mm (5.7) 5 mm(0.2)

Fig. 2.31

Eathquake kit: Internal Plate

Fig. 2.32

Anchor Kit S30861-K126-X

37,5 mm (1.5)

275 mm (10.8)

5 mm(0.02)

220 mm (8.7)

A30808-X3247-M460-3-7631

59

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

1 2 3 4 5

Fig. 2.33

Anchoring screw S30861-K126 assembled on M12/50 anchor

Fig. 2.34

Fastening of the HSL M12/50 anchor

60

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 2.35

Rack fixed on the floor

A30808-X3247-M460-3-7631

61

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

2.6.2

Grounding connections for the TRAU-HC Rack


The rack has to be connected to the site specific ground system before to starting the connection of the power cable

ground bolts Fig. 2.36 RCAP of the TRAU rack

To grounding the rack use a 16mm2/5AWG or 25mm2/3AWG PVC Ye/Gr copper wire. The connection should be connected to a ground collector bar on the shortest way. Mounting instruction of the grounding of the rack (see Fig. 2.36): Use the nearest ground system on site. Verify the distances between the connection point of the ground system and the ground bolts of the rack. Cut the wire to the required length. Unsheet the wire at the end and crimp a two-hole M6 lug terminal (i.e. Thomas & Betts type 54852BE blue color for 16mm2/6AWG or 54856BE brown color for 25mm2/3AWG). Remove exagonal nut, lock washer and contact washer from the ground bolt. Connect the prepared wire to the ground bolts by a two-hole lug terminal. Replace the contact washer, lock washer and hexagonal nut. Tighten the hexagonal nut rmly.

62

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

3 TRAU Power Supply


3.1 Requirements
The equipment shall be connected to a 48V DC SELV source which is electrically isolated from the AC source and which is reliably connected to earth.

The BSCIV4, as well as TRACV5 and MSCIV2, can be powered by the on board DC/DC converter and in this case the Power Supply Module (PWRS) is not equipped. The equipment and the strap configuration of these modules are described in the TRAU Maintenance Manual.

3.2

Overview
The TRAU rack has to be connected to a 48 VDC Power Distribution Rack (PDR). For reasons of reliability, two power suppliers at 48V start from PDR, each one provided with an individual protection. The two couples of conductors at 48V, are directly connected to the PP0 and PP1 terminals (max conductor cross-section is 10mm2) located on the Rack Cabling Access Panel (see Fig. 3.1). When connecting the power supply cables use different colors, like blue and black (or brown) and take into account that: PDR side: The BLACK conductor must be connected to the positive polarity of the secondary power and then to the protective earth collector; The BLUE conductor must be connected to the negative polarity of the secondary power. The BLACK conductor must be connected to terminal "+" The BLUE conductor must be connected to terminal "- 48V

Rack side:

The power supply units of the TRAU subsystem operate at a voltage of 48 V (range:38.4-57.6 V). They provide two output voltages +5,3 V and +12,3 V with a tolerance of +/- 2%. The power supply units are switched off in an irreversible way if the output voltage exceeds a protection threshold of +15%; if the output voltage drops below a protection threshold of -5%, the power supply units are switched off and then automatically restored when the voltage returns above the threshold value. Two power supply units, copy 0 and copy 1, are provided for the TRAU subrack. Each power supply is powered in an independent way and each module is powered by two independent conductors at -48V.

A30808-X3247-M460-3-7631

63

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

3.3

TRAU Rack Power Requirements


Voltage -48VDC Max power consumption for subrack/frame 120W for TRAU Standard 110W fro TRAU HC Max power consumption for TRAU rack 480W fro TRAU Standard 470W for TRAU HC Power protection on Alarm and Fuse Panel 2 x 10A fuses for TRAU standard 2 x 4A breakers for TRAU HC Upstream Protection Breakers or Fuses (see Note 1) The TRAU subsystem comprises redundant equipment for reasons of reliability. All the boards of the TRAU system, except TRAC boards, are duplicated and operate in activehot standby configuration. The copy 0 of the duplicated boards are powered by the power supply copy 0 and the copy 1 by the power supply copy 1. The TRAC boards, having a system redundance N+1, receive a double supply voltage, from power supplier copy 0 and power supplier copy 1, with decoupling diodes. Note 1: The choice of the breakers/fuses, to mount upstream (in a Power Distribution Rack) the TRAU rack, and the cross-section of the conductors, to connect between the Power Distribution Rack and the TRAU rack, should be based on the typical parameters of the installation (Power Station, ohmic resistance of the cabling, max voltage drop accepted on the TRAU power line, etc.). All these data are known to the Service people and are should be taken in order to have the right coordination of the protections. In a general way it is possible: to use an automatic breaker supplied by SIEMENS S.p.A. as an example of its characteristics: Nominal Current=20A; Single pole; Curve C; Type 5SY4 or 5SY6 connect the TRAU rack from a Power Distribution Rack to a distance of 30m (100ft), using a 10mm2 (7AWG) conductors cross-section

For markets requiring UL compliance use UL-Listed automatic breaker

64

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

3.4

Primary Power Connection


Installation of the DC wires (see Fig. 3.1) is as follows: Verify the distance between the connection points of the Power Distribution Rack system and the terminals (on the RCAP) of the power entry of the TRAU rack. Cut the wires to the required length. TRAU rack side: unsheet the wires about 10mm (0.4) PDR side: installation dependent Remove the cover of the Power Line entry on the RCAP. Insert the wires into holes. Connect the prepared wire as follows: BLUE wire to Terminal -48V; BLACK (BROWN) wires to terminal +48V. Check the correct polarity of the connection from the TRAU rack and the DC output of the PDR. Replace the cover of the Power Line entry.

cover

terminals for power line connection power1 power 0

power 0 power1 power line entry

Fig. 3.1

TRAU-Standard power IN

A30808-X3247-M460-3-7631

65

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

terminals for power line connection power 0 power 1 cover

power line entry Fig. 3.2 TRAU-HC power IN

66

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4 PCM and ALARM connection


This chapter provides the information required for installing the external cables between the TRAU rack (RCAP Fig. 4.1 and Fig. 4.2) and the infrastructure equipment on site. The rack cannot function without the following cable connections: an external -48VDC power supply. ground connection Abis interface optional: remote alarms interface Note: For what concerns interconnecting cables and cable assemblies used for external interconnection between parts of equipment or between components of system, the following directives apply to all countries that operate according to UL or CB certificate: For external cables longer than 3,5 m (approximately 10 ft), the following must be used: Listed CL-2 or Listed Communication Cable (DUZX), type CM or CMR, rated 150 Vac, 75C. For external cables less than 3,5 m (approximately 10 ft) the following can be used: Listed or constructed of materials rated minimum FT-1 or VW-1. Furthermore each detachable external interconnecting non-Listed cable with terminations must be identied by a tag or a non-permanent label reporting the logo "Siemens AG" and the "cables identifying designation"; marking applied on the cable at any location or locations. Two types of cables can be used for the Asub/A interface (PCM lines): coaxial cables (using an Adapter inserted on SUB-D37 connectors) balanced cables

Fig. 4.1

TRAU Standard top view : Rach Cabling Access Panel (RCAP)

A30808-X3247-M460-3-7631

67

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 4.2

TRAU-HC top view : Rach Cabling Access Panel (RCAP)

68

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4.1

Asub/A interface connection of the TRAU Standard rack


The Asub/A connection provides the communication links to the MSC equipment and to BSC equipment. The connection can be performed either coaxial cable or balanced cable. The Abis interface is terminated with the Overvoltage Protection (OVPT) that protects the boards inside the rack against overvoltage (residual voltage <1kV). The connector (SUB-D37) of the OVPTis mounted on the RCAP of the rack (see Fig. 4.1).

Use only coaxial cable for 75ohm wiring, e.g. INTERCOND 13-RJC19A12R-C1 (12x0.4/1.9) and relative 1.0/2.3 coaxial connector, e.g. COMPEL 350.064.050 or INTERCOND 11-RK23/4 (single coaxial) and relative 1.0/2.3 coaxial connector, e.g. COMPEL 350.064.054. Use onlybalanced cable 100/120ohm, e.g. INTERCOND 13-TDH26P12R-C1 12x2xAWG26 twisted shielded pairs (with drain wire) plus total braided shield and relative SUB-D 37 connector.

The Tab. 4.1 and Tab. 4.2 gives the corresponding of the PCM connection between the TRAU subrack, the TRAU module and the connector of the RCAP rack. TRAU Subrack 3 4 Tab. 4.1 3 4 Left TRAUs PCM lines TRAU Module RCAP Connector LINK 3 (GW6) LINK 4 (LW6)

TRAU Subrack 1 2 Tab. 4.2 1 2

TRAU Module

RCAP Connector LINK 1 (AW6) LINK 2 (DW3)

Right TRAUs PCM lines

A30808-X3247-M460-3-7631

69

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

The pinning of any PCM connector on the RCAP of the rack is shown in Tab. 4.3. The wire color is referred to the rack internal cable and is corresponding to the table CEIUNEL 00724. PIN CONNECTOR # 1/20 2/21 3 4/22 5/23 6/24 7/25 26 8/27 9/28 10 11/29 12/30 13/31 14/32 33 15/34 16/35 17 18/36 19/37 Tab. 4.3 PCM 0 Input PCM 0 Output GROUND PCM 1 Input PCM 1 Output PCM 0 Input PCM 0 Output GROUND PCM 1 Input PCM 1 Output GROUND PCM 2 Input PCM 2 Output PCM 3 Input PCM 3 Output GROUND ----------------------------GROUND ----------------------------PCM Lines connector pinning (from MSC) (to MSC) (from MSC) (to MSC) (from MSC) (to MSC) (from BSC) (to BSC) (from MSC) (to MSC) PCM LINE (from BSC) (to BSC) WIRE COLOR BLUE/WHITE ORANGE/WHITE SHIELD GREEN/WHITE BROWN/WHITE GREY/WHITE BLUE/RED SHIELD ORANGE/RED GREEN/RED SHIELD BROWN/RED GREY/RED BLUE/BLACK ORANGE/BLACK SHIELD Not connected Not connected SHIELD Not connected Not connected

70

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4.1.1

Coaxial cable connection


For Asub/A cabling 75ohm impedance use coaxial cable and relative 1.0/2.3 coaxial connector.

To assembly the coaxial cable and relative connector, please refer to the assembling procedures of the connector Supplier The Asub/A interface should be connected by a coax Adapter C39117-A343-A48 (see Fig. 4.3, Fig. 4.4, Tab. 4.4)
TX cables to BSC side TX cables to MSC side Not Used

1
0 1 0 1 2 3

RX cables to BSC side

RX cables to MSC side

Not Used

Fig. 4.3

Coax Adapter mounted on left side (GW6, LW6)

A30808-X3247-M460-3-7631

71

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Not used

RX cables to MSC side

RX cables to BSC side

Not Used

TX cables to MSC side

TX cables to BSC side

Fig. 4.4

Coax Adapter mounted on right side (AW6, DW6)

Preparation of the coaxial cable TRAU rack side Cut the cable to the required length. Unsheet the cable as per connector assembling procedures. Fix a 1.0/2.3 female connector (e.g. ROSENBERGER 34S101-341H3 for the cable 2YCCY 0.4/2.5) for any PCM-Input and Output line at the end to be connected to the coax Adapter. Connect the prepared cable to the matching connectors. Use a torque spanner for 1.0/2.3 connector (35 N/cm). Signal PCM 0 Input PCM 0 Output PCM 1 Input PCM 1 Output Coax connector RX 0 (BSC side) TX 0 (BSC side) RX 1 (BSC side) TX 1 (BSC side) Signal PCM 0 Input PCM 0 Output PCM 1 Input PCM 1 Output PCM 2 Input PCM 2 Output PCM 3 Input PCM 3 Output Tab. 4.4 Pinning of the 75ohm PCM on Adapter board Coax connector RX 0 (MSC side) TX 0 (MSC side) RX 1 (MSC side) TX 1 (MSC side) RX 2 (MSC side) TX 2 (MSC side) RX 3 (MSC side) TX 3 (MSC side)

Preparation of the coaxial cable on Installation side The connector type to be used is a site installation dependent; the choice of the right connector and possible terminals block to mount on a Main Distribution Frame (MDF) is Service people care.

72

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4.1.2

Balanced cable connection


For Asub/A cabling 100/120ohm impedance use a balanced cable twisted shielded pairs (with drain wire) plus total braided shield and relative SUB-D 37 Male connector.

The outer diameter of the PCM cable must not exceed 15mm (0.59) The pinning of the PCM signal is reported in the Tab. 4.5 Pin connector 1/20 2/21 3 4/22 5/23 6/24 7/25 26 8/27 9/28 10 11/29 12/30 13/31 14/32 33 15/34 16/35 17 18/36 19/37 Tab. 4.5 PCM line PCM 0 Input (BSC) - RXP0/RXN0 PCM 0 Output (BSC) - TXP0/TXN0 GND PCM 1 Input (BSC) - RXP1/RXN1 PCM 1 Output (BSC) - TXP1/TXN1 PCM 0 Input (MSC) - RXP0/RXN0 PCM 0 Output (MSC) - TXP0/TXN0 GND PCM 1 Input (MSC) - RXP1/RXN1 PCM 1 Output (MSC) -TXP1/TXN1 GND PCM 2 Input (MSC) - RXP2/RXN2 PCM 2 Output (MSC) - TXP2/TXN2 PCM 3 Input (MSC) - RXP3/RXN3 PCM 3 Output (MSC) - TXP3/TXN3 GND Not connected Not connected GND Not connected Not connected Pinning of the PCM connector

Preparation of the balanced cable TRAU rack side

A30808-X3247-M460-3-7631

73

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Cut the cable to the required length. Remove external jacket about 70 mm (2.7) Free all pairs from respective shields about 55 mm (2.1) (dont cut the drain wire). Connect the pairs as per Tab. 4.5 (connect to GND the drain wire of the pairs) using a SUB-D37 Male (e.g. CANNON ZDC37PA191). Close the connector with a shielded cap with screws M3 (e.g. FCT FMK4GK201+2FRS1Y5-K190-M3). Be careful: the outer shield of the cable must be in contact with the cable clamping of the said cap.

Preparation of the balanced cable on Installation side The connector type to be used is a site installation dependent; the choice of the right connector is Service people care. The following Fig. 4.5 shows a possible termination on a 6x30 terminal block of the Main Distribution Frame (MDF). The wires color is the same color of the wires of the internal cable and is corresponding to the table CEI-UNEL 00724.

Fig. 4.5

PCM line connections to MDF (to/from BSC and MSC)

74

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4.2
4.2.1

Alarms connection of the TRAU Standard rack


Remote Alarms connection
This connection is used to send the TRAU alarms to a remote location. The connectors of the TRAU RCAP are associated to the TRAU subrack, TRAU module according the following Tab. 4.6 and Tab. 4.7. TRAU Subrack 3 4 Tab. 4.6 3 4 Left TRAUs Remote alarms TRAU Module RCAP Connector GW3 LW3

TRAU Subrack 1 2 Tab. 4.7 1 2

TRAU Mdule

RCAP Connector AW3 DW3

Right TRAUs Remote alarms

For Remote alarms cabling use a 13x2x0.4 (13x2xAWG24/26) twisted pairs plus total braided shield and relative SUB-D 25 Male connector.

i i

The outer diameter of the Remote Alarms cable must not exceed 12mm (0.47) The maximum length between the remote alarms connector and the output device should be calculated taking into account that the nominal loading of each relay contact is 0,3A/48VDC. The alarm signals are associated to as many relay contacts to send the following alarm conditions: BSC link alarm Spare alarm Spare alarm OR of BS-MS-INT Global alarm: Major Global alarm: Minor Global alarm: Critical OR of MJ-MN-CR (BS) (MS) (INT) (OR2) (MJ) (MN) (CR) (OR1)

A30808-X3247-M460-3-7631

75

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Tab. 4.8 shows the layout of the pins of the connector AW3/DW3/GW3/LW3, situated on the RCAP.The wire color is referred to the internal cable and is corresponding to the table CEI-UNEL 00724. Alarm Type BSC LINK ALARM Signal Name BS-BK BS-CM BS-MK SPARE ALARM MS-BK MS-CM MS-MK SPARE ALARM INT-BK INT-CM INT-MK OR OF BS-MSINT ALARMS OR2-BK OR2-CM OR2-MK Pin Number 01 02 03 04 05 06 07 08 09 10 11 12 13 GLOBAL ALARM: MAJOR GLOBAL ALARM: MINOR GLOBAL ALARM: CRITICAL OR OF MJ_MN_CR ALARMS MJ-BK MJ-CM MJ-MK MN-BK MN-CM MN-MK CR-BK CR-CM CR-MK OR1-BK OR1-CM OR1-MK Tab. 4.8 14 15 16 17 18 19 20 21 22 23 24 25 RED ORN RED GRN RED BRN RED GRY BLK BLU BLK ORN Wire Color WHT BLU WHT ORN WHT GRN WHT BRN WHT GRY RED BLU

Layout of the pins of connector AW3/DW3/GW3/LW3

76

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

In general, the condition of each type of alarm is notified through a relay contact in the following way: no alarm: contact RELAY-COMMON/RELAY-BREAK contact RELAY-COMMON/RELAY-MAKE contact RELAY-COMMON/RELAY-BREAK contact RELAY-COMMON/RELAY-MAKE closed open open closed

alarm state:

Where RELAY-COMMON indicates the common point of the contact (CM), RELAYBREAK indicates the break point (no alarm) of the contact (BK), and RELAY-MAKE indicates the make point (alarm) of the contact (MK). Preparation of the Remote Alarm cable TRAU rack side Cut the cable to the required length. Remove external jacket about 70 mm (2.7) Cut the outer shield leaving about 10mm (0.4) to permit its contact with the campling of the cap. Connect the pairs as per Tab. 4.9 (the wire color is referred to the internal cable and is corresponding to the table CEI-UNEL 00724) using a SUB-D25 Male (e.g. CANNON ZDB25PA191). Close the connector with a shielded cap with screws M3 (e.g. FCT FMK3GK201+2FRS1Y5-K190-M3). Be careful: the outer shield of the cable must be in contact with the cable clamping of the said cap.

Pair Color WHT/BLU WHT/ORG WHT/GRN WHT/BRN WHT/GRY RED/BLU WHT/GRY RED/GRN RED/BRN RED/GRY BLK/BLU BLK/ORG BLK/GRN Tab. 4.9

Signal BSBK/MJBK BSCM/MJCM BSMK/MJMK MSBK/MNBK MSCM/MNCM MSMK/MNMK INTBK/CRBK INTCM/CRCM INTMK/CRMK OR2BK/OR1BK OR2CM/OR1CM OR2MK/OR1MK ----------------

Connector Pin 1/14 2/15 3/16 4/17 5/18 6/19 7/20 8/21 9/22 10/23 11/24 12/25 Not connected

Pinning of the Remote Alarm cable

A30808-X3247-M460-3-7631

77

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Preparation of the Remote Alarm cable on Installation side The connector type to be used is a site installation dependent; the choice of the right connector is Service people care. The following Fig. 4.6 shows a possible termination on a 6x30 terminal block of the Main Distribution Frame (MDF). The wires color is the same color of the wires of the internal cable and is corresponding to the table CEI-UNEL 00724. The left part (*) of the MDF block in Fig. 4.6 can be used for alarms from BSC, when the BSC and the TRAU racks are co-located. All these alarm signals can be connected to output devices such as lamps, bells, horns, taking into account that the nominal loading of each relay contact is 0,3A/48VDC; only security voltages (60VDC max or 42,4Vpk max) can be connected to these circuits.

The cable shield must be grounded at Installation (e.g. MDF) side

Fig. 4.6

Remote Alarm connection to terminal block

78

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

4.2.2

Internal Alarms connection (W14, W15 connectors)


The internal alarms are connected between the connectors W14, W15 of the TRAU subracks and the connector PM2 of the TRAU Rack Cabling Access Panel. The Tab. 4.10 shows the pinning of the connectors W14 and W15. Pin 1 2 3 4-9 5 6 8 7 MJB CRB MNB signal name BSB MSB INTB CM2,CM1 BSC link alarm not used Open door alarm - 48 V not used major alarm critical alarm minor alarm ground description

10 - 11 GND Tab. 4.10

Pin description of the connectors W14 and W15

In the last lower subrack on the connector W14 takes place the Open door sensor cable. The two wires of the sensor are connected to pin number 3 and to ground (by the cableclamp of the shielded cap). During an upgrade of a subrack needs to: disconnect the cable connected to connector W14 on the last subrack equipped. mount the new subrack. reconnect the cable disconneted from connector W14 on the new subrack. connect the cable V7440-A32-R32 (item of the new subrack) between the connector W15 of the new subrack and the connector W14 of the last equipped subrack.

For references see Fig. 5.4 and Fig. 5.5 of the Chap. 5.

A30808-X3247-M460-3-7631

79

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

4.3

Asub/A interface connection of the TRAU-HC rack


The Asub/A connection provides the communication links to the MSC equipment and to BSC equipment. The connection can be performed either coaxial cable or balanced cable. The Asub/A interface is terminated with the Overvoltage Protection (OVPT) that protects the boards inside the rack against overvoltage (residual voltage <1kV). The connector (SUB-D37) of the OVPTis mounted on the RCAP of the rack (see Fig. 4.1).

Use only coaxial cable for 75ohm wiring, e.g. INTERCOND 13-RJC19A12R-C1 (12x0.4/1.9) and relative 1.0/2.3 coaxial connector, e.g. COMPEL 350.064.050 or INTERCOND 11-RK23/4 (single coaxial) and relative 1.0/2.3 coaxial connector, e.g. COMPEL 350.064.054. Use only balanced cable 100/120ohm, e.g. INTERCOND 13-TDH26P12R-C1 (12x2x0.4) 12x2xAWG26 twisted shielded pairs (with drain wire) plus total braided shield and relative SUB-D 37 connector.

The Tab. 4.11 and Tab. 4.12 gives the corresponding of the PCM connection between the TRAU frame, the TRAU module and the connector of the RCAP rack. TRAU Frame 0 1 2 3 Tab. 4.11 0 2 4 6 Left TRAUs PCM lines TRAU Module RCAP Connector LINK 0 (PCM 0) LINK 2 (PCM 2) LINK 4 (PCM 4) LINK 6 (PCM 6)

TRAU Frame 0 1 2 3 Tab. 4.12 1 3 5 7

TRAU Module

RCAP Connector LINK 1 (PCM 1) LINK 3 (PCM 3) LINK 5 (PCM 5) LINK 7 (PCM 7)

Right TRAUs PCM lines

80

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

The pinning of any PCM connector on the RCAP of the rack is shown in Tab. 4.3. PIN CONNECTOR # 1/20 2/21 3 4/22 5/23 6/24 7/25 26 8/27 9/28 10 11/29 12/30 13/31 14/32 33 15/34 16/35 17 18/36 19/37 Tab. 4.13 PCM 0 Input PCM 0 Output GROUND PCM 1 Input PCM 1 Output PCM 0 Input PCM 0 Output GROUND PCM 1 Input PCM 1 Output GROUND PCM 2 Input PCM 2 Output PCM 3 Input PCM 3 Output GROUND Not used Not used GROUND Not used Not used PCM Lines connector pinning (from MSC) (to MSC) (from MSC) (to MSC) (from MSC) (to MSC) (from BSC) (to BSC) (from MSC) (to MSC) PCM LINE (from BSC) (to BSC)

A30808-X3247-M460-3-7631

81

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

4.3.1

Coaxial cable connection


For Asub/A cabling 75ohm impedance use coaxial cable and relative 1.0/2.3 coaxial connector.

To assembly the coaxial cable and relative connector, please refer to the assembling procedures of the connector Supplier The Asub/A interface should be connected by a coax Adapter S30861-Q472-X (see Fig. 4.7, Tab. 4.14)
TX cables to BSC side TX cables to MSC side

1
0 1 0 1 2 3

RX cables to BSC side

RX cables to MSC side

Fig. 4.7

Coax Adapter mounted on left and right side

Preparation of the coaxial cable TRAU rack side Cut the cable to the required length. Unsheet the cable as per connector assembling procedures. Fix a 1.0/2.3 female connector (e.g. ROSENBERGER 34S101-341H3 for the cable 2YCCY 0.4/2.5) for any PCM-Input and Output line at the end to be connected to the coax Adapter. Connect the prepared cable to the matching connectors. Use a torque spanner for 1.0/2.3 connector (35 N/cm).

82

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Signal PCM 0 Input PCM 0 Output PCM 1 Input PCM 1 Output

Coax connector RX 0 (BSC side) TX 0 (BSC side) RX 1 (BSC side) TX 1 (BSC side)

Signal PCM 0 Input PCM 0 Output PCM 1 Input PCM 1 Output PCM 2 Input PCM 2 Output PCM 3 Input PCM 3 Output

Coax connector RX 0 (MSC side) TX 0 (MSC side) RX 1 (MSC side) TX 1 (MSC side) RX 2 (MSC side) TX 2 (MSC side) RX 3 (MSC side) TX 3 (MSC side)

Tab. 4.14

Pinning of the 75ohm PCM on Adapter board

Preparation of the coaxial cable on Installation side The connector type to be used is a site installation dependent; the choce of the right connector and possible terminals block to mount on a Main Distribution Frame (MDF) is Service people care.

A30808-X3247-M460-3-7631

83

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

4.3.2

Balanced cable connection


For Asub/A cabling 100/120ohm impedance use a balanced twisted shielded pairs (with drain wire) plus total braided shield and relative SUB-D 37 Male connector.

The outer diameter of the PCM cable must not exceed 15mm (0.59) The pinning of the PCM signal is reported in the Tab. 4.15 Pin connector 1/20 2/21 3 4/22 5/23 6/24 7/25 26 8/27 9/28 10 11/29 12/30 13/31 14/32 33 15/34 16/35 17 18/36 19/37 Tab. 4.15 PCM line PCM 0 Input (BSC) - RXP0/RXN0 PCM 0 Output (BSC) - TXP0/TXN0 GND PCM 1 Input (BSC) - RXP1/RXN1 PCM 1 Output (BSC) - TXP1/TXN1 PCM 0 Input (MSC) - RXP0/RXN0 PCM 0 Output (MSC) - TXP0/TXN0 GND PCM 1 Input (MSC) - RXP1/RXN1 PCM 1 Output (MSC) -TXP1/TXN1 GND PCM 2 Input (MSC) - RXP2/RXN2 PCM 2 Output (MSC) - TXP2/TXN2 PCM 3 Input (MSC) - RXP3/RXN3 PCM 3 Output (MSC) - TXP3/TXN3 GND Not connected Not connected GND Not connected Not connected Pinning of the PCM connector

84

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Preparation of the balanced cable TRAU rack side Cut the cable to the required length. Remove external jacket about 70 mm (2.7) Free all pairs from respective shields about 55 mm (2.1) (dont cut the drain wire). Connect the pairs as per Tab. 4.15 (connect to GND the drain wire of the pairs) using a SUB-D37 Male (e.g. CANNON ZDC37PA191). Close the connector with a shielded cap with screws M3 (e.g. FCT FMK4GK201+2FRS1Y5-K190-M3). Be careful: the outer shield of the cable must be in contact with the cable clamping of the said cap. Preparation of the balanced cable on Installation side The connector type to be used is a site installation dependent; the choice of the right connector and the arrangement on a possible terminal block to mount on a Main Distributor Frame (MDF) is Service people care.

A30808-X3247-M460-3-7631

85

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

4.4
4.4.1

Alarms connection of the TRAU-HC rack


Remote Alarms connection
This connection is used to send the TRAU alarms to a remote location. The connectors of the TRAU RCAP are associated to the TRAU frame, TRAU module according the following Tab. 4.16 and Tab. 4.17. TRAU Frame 0 1 2 3 Tab. 4.16 0 2 4 6 Left TRAUs Remote alarms TRAU Module RCAP Connector AW0 AW2 AW4 AW6

TRAU Frame 0 1 2 3 Tab. 4.17 1 3 5 7

TRAU Module

RCAP Connector AW1 AW3 AW5 AW7

Right TRAUs Remote alarms

For Remote alarms cabling use a 2x13x0.4 (2x13xAWG24/26) twisted pairs plus total braided shield and relative SUB-D 25 Male connector.

i i

The outer diameter of the PCM cable must not exceed 12mm (0.47) The maximum length between the remote alarms connector and the output device should be calculated taking into account that the nominal loading of each relay contact is 0,3A/48VDC. The alarm signals are associated to as many relay contacts to send the following alarm conditions: BSC link alarm Spare alarm Spare alarm OR of BS-MS-INT Global alarm: Major Global alarm: Minor Global alarm: Critical OR of MJ-MN-CR (BS) (MS) (INT) (OR2) (MJ) (MN) (CR) (OR1)

86

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Tab. 4.18 shows the layout of the pins of the connector AW0-AW7, situated on the RCAP. Alarm Type BSC LINK ALARM Signal Name BS-BK BS-CM BS-MK SPARE ALARM MS-BK MS-CM MS-MK SPARE ALARM INT-BK INT-CM INT-MK OR OF BS-MSINT ALARMS OR2-BK OR2-CM OR2-MK Pin Number 01 02 03 04 05 06 07 08 09 10 11 12 13 GLOBAL ALARM: MAJOR GLOBAL ALARM: MINOR GLOBAL ALARM: CRITICAL OR OF MJ_MN_CR ALARMS MJ-BK MJ-CM MJ-MK MN-BK MN-CM MN-MK CR-BK CR-CM CR-MK OR1-BK OR1-CM OR1-MK Tab. 4.18 14 15 16 17 18 19 20 21 22 23 24 25

Layout of the pins of connector AW0-AW7

A30808-X3247-M460-3-7631

87

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

In general, the condition of each type of alarm is notified through a relay contact in the following way: no alarm: contact RELAY-COMMON/RELAY-BREAK contact RELAY-COMMON/RELAY-MAKE contact RELAY-COMMON/RELAY-BREAK contact RELAY-COMMON/RELAY-MAKE closed open open closed

alarm state:

Where RELAY-COMMON indicates the common point of the contact (CM), RELAYBREAK indicates the break point (no alarm) of the contact (BK), and RELAY-MAKE indicates the make point (alarm) of the contact (MK). Preparation of the Remote Alarm cable TRAU rack side Cut the cable to the required length. Remove external jacket about 70 mm (2.7) Cut the outer shield leaving about 10mm (0.4) to permit its contact with the campling of the cap. Connect the pairs as per Tab. 4.19 (the wire color is referred to the internal cable and is corresponding to the table CEI-UNEL 00724) using a SUB-D25 Male (e.g. CANNON ZDB25PA191). Close the connector with a shielded cap with screws M3 (e.g. FCT FMK3GK201+2FRS1Y5-K190-M3). Be careful: the outer shield of the cable must be in contact with the cable clamping of the said cap.

Pair Color WHT/BLU WHT/ORG WHT/GRN WHT/BRN WHT/GRY RED/BLU WHT/GRY RED/GRN RED/BRN RED/GRY BLK/BLU BLK/ORG BLK/GRN Tab. 4.19

Signal BSBK/MJBK BSCM/MJCM BSMK/MJMK MSBK/MNBK MSCM/MNCM MSMK/MNMK INTBK/CRBK INTCM/CRCM INTMK/CRMK OR2BK/OR1BK OR2CM/OR1CM OR2MK/OR1MK ----------------

Connector Pin 1/14 2/15 3/16 4/17 5/18 6/19 7/20 8/21 9/22 10/23 11/24 12/25 Not connected

Pinning of the Remote Alarm cable

88

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Preparation of the Remote Alarm cable on Installation side The connector type to be used is a site installation dependent; the choice of the right connector and the arrangement on a possible terminal block on a Main Distributor Frame (MDF) is Service people care. All these alarm signals can be connected to output devices such as lamps, bells, horns, taking into account that the nominal loading of each relay contact is 0,3A/48VDC; only security voltages (60VDC max or 42,4Vpk max) can be connected to these circuits.

The cable shield must be grounded at Installation (e.g. MDF) side

A30808-X3247-M460-3-7631

89

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

5 System Cabling of the TRAU rack


This chapter reports an overview of the internal cabling of the TRAU rack

5.1

TRAU Standard rack


The following Tab. 5.1 shows the function and the type of connector positioned on the Rack Cabling Access Panel .

Connector position PP0 PP1 AW3 DW3 GW3 LW3 PM2 AW6 DW6 GW6 LW6 TERMINALS

Type

Function Power supply Connected to PDR TRAU 0 alarms to remote location TRAU 1 alarms to remote location TRAU 2 alarms to remote location TRAU 3 alarms to remote location Rack Lamp alarms (connected together) PCM line connections to BSC and MSC for TRAU-0 PCM line connections to BSC and MSC for TRAU-1 PCM line connections to BSC and MSC for TRAU-2 PCM digital connections to BSC and MSC for TRAU-3

SUB D 25 Female SUB D 25 Female SUB D 25 Female SUB D 25 Female SUB D 9 Female SUB D 37 Female SUB D 37 Female SUB D 37 Female SUB D 37 Female

Tab. 5.1

Connectors position, type and function

90

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

The Fig. 5.1 shows the position of the connectors on the RCAP of the rack

Fig. 5.1

TRAU Rack - Top view

A30808-X3247-M460-3-7631

91

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

The Fig. 5.2 shows a side view of the rack with the subrack power supply connection (bus-bar) and the connection of the cables on the RCAP

Rack right top side

Rack left side Fig. 5.2 Rack left side and rack right top side

92

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

The Fig. 5.3 shows a front view of the rack with the subrack power supply connection (bus-bar and filter) and ground connection.

Fig. 5.3

Power and ground cables distribution

A30808-X3247-M460-3-7631

93

IMN:TRAU

Installation Transcoding and Rate Adaption Unit The Fig. 5.4 shows the list of the cabling of the TRAU rack.

Fig. 5.4

Interconnections list

94

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Notes on interconnection list 3 - This cable is a part of the F:TRAUE (Expansion frame). Here listed for mounting reference only. 4 - this cable is fitted by rack supplier. Here listed for mounting reference only. 5 - Side 1 of the Open sensor cable (57) has to be terminated to W14 connector of TRAU module equipped in lower position; secure cable along vertical duct using provided cable ties (ref. 58 and 59). The Fig. 5.5 shows the connectors of the Fuse Pane in open position. Rem-Alm to TOP(AW3) to Fuse Panel (J1) (J2)

48VA

to top(AW6) PCM lines

from Door-Open sensor to W14 upper subrack or to PM2 on RCAP

48VB

from PM3 temp. sensors

Fig. 5.5

TRAU Sub-rack: front view (fuse panel shown in open position)

A30808-X3247-M460-3-7631

95

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

The Fig. 5.5 shows the cabling of the Fuse Panel.

Fig. 5.6

TRAU sub-rack: Fuse Panel Mounting and Cabling

Mounting Reference File 55 56 58 58 60 Tab. 5.2 W W W W W

From Connector W5 W4 W1 W16 GNDF File

To Connector

Fuse Pan. J1 Fuse Pan. J2 Fuse Pan. J4 Fuse Pan. J5 Fuse Pan. GNDF

Table of the Fuse Panel cabling

96

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

5.2

TRAU-HC rack
This chapter reports an overview of the internal cabling of the TRAU rack. The chapter is developped in the following four blocks: 1. 2. 3. 4. Adapter Board cabling DC-Panel cabling PCM lines cabling Photographs of the wiring assembly

5.2.1

Adapter Board cabling (M:ADAPTBTV1)


Adapter Board card (S30861-Q476-X) takes place on the top of the rack (see Fig. 5.7, Fig. 5.8 and Fig. 5.9) and has the following functions : 48 V power supply from EMI-Filter to all DC-Panel,Lamp Panel,Fan unit and Temperature Monitor Thermal alarms from Temperature Monitor Fan alarm from Fan unit Open door alarm from open door sensor Board alarms from all TRAU cards to Lamp Panel

Fig. 5.7

Adapter Board layout

A30808-X3247-M460-3-7631

97

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 5.8

Adapter Board layout

98

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 5.9

Adapater Board system block diagram

A30808-X3247-M460-3-7631

99

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

LIST OF THE CONNECTORS AND CABLES OF THE ADAPTER BOARD (refer Fig. 5.9).

X25 connector The X25 connector is used to send board alarms and to power Lamp Panel at the top of the rack (PM2 connector). Connector code is D Subminiature right-angle solder termination 9p. pin 1 2 3 4 5 6 7 8 9 Tab. 5.3 Signal N.C. N.C. N.C VAB -VAB MJ MN + 48 V - 48 V Major alarm Minor alarm not connected Description

Critical Critical alarm -VAB - 48 V

X25 connector of the Adapter Board

RCAP-LAMP PANEL CABLE

100

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

X23-X24 Connectors The faston X23-X24 are used to receive open door alarm that is a contact from a sensor. The type is a faston pressfit. pin X23 X24 Tab. 5.4 Signal OPEND GND Open door ground Description

X23,X24 connectors of the Adapter Board

OPEN DOOR SENSOR CABLE

A30808-X3247-M460-3-7631

101

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

X27 connector The X27 connector is used to receive fan alarm from FAN unit. The type is D Subminiature pressfit termination 15p. pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Tab. 5.5 N.C. N.C. N.C GND TRAU_FANAL N.C. N.C. N.C. N.C. N.C. GND N.C. N.C. N.C. N.C. X27 connector of the Adapter Board Fan alarm Signal Description

FAN UNIT ALARM CABLE

102

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

X26 connector The X26 connector is used for DAISY CHAIN that connects the sub-racks with the following signals: TRAU alarms (MJ,MN,MCR,EXT) that are in logical OR between the sub-racks. POWER OFF A and B alarms. OPEND alarm. FAN alarm,. The type is 20pin, 2x10 pressfit termination. Daisy chain is constituted with a crimped flat cable. pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Tab. 5.6 Signal TEST_PWOFFA Test thermal alarm A PWOFFA Thermal alarm A Description

TEST_PWOFFB Test thermal alarm B PWOFFB - VAB OPEND MN GND N.C. FAN N.C. MN N.C. MJ N.C. MCR N.C. EXT N.C. GND X26 connector of the Adapter Board External BSCI alarm Critical alarm Major alarm Minor alarm Fan alarm Thermal alarm B - 48 V Open door alarm Minor alarm

A30808-X3247-M460-3-7631

103

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

DAISY CHAIN CABLE

(169)

104

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

X5-X6 connector The faston X5-X6 are used to feed Fan unit. The type is a faston pressfit. pin5 X5 X6 Tab. 5.7 Signal + VAB - VAB + 48 V - 48 V Description

X5,X6 connectors of the Adapter Board

DC-FAN UNIT CABLE

X1-X2 and X3-X4 connectors The faston X1-X2 and X3-X4 are used to receive power supply from EMI-Filter. The type is a faston pressfit. pin 1 2 3 4 Tab. 5.8 Signal 48A - 48A 48B - 48B + 48 V battery A - 48 V battery A + 48 V battery B - 48 V battery B Description

X1,X2 and X3,X4 connectors of the Adapter Board

DC-MAIN CABLES

A30808-X3247-M460-3-7631

105

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

X7 to X22 connector The faston X7 to X22 are used to feed TRAU frames. The type is a faston pressfit. Ref. X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X20 X21 X22 Tab. 5.9 frame 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 Signal + 48 A - 48 A + 48 B - 48 B + 48 A - 48 A + 48 B - 48 B + 48 A - 48 A + 48 B - 48 B + 48 A - 48 A + 48 B - 48 B X7 to X22 connectors of the Adapter Board

DC-MAIN TO DC-PANEL CABLES

106

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

5.2.2

Front-Panel Board cabling


The Front Panel Board (S50201-Q54-X) is positioned in the DC-Panel in a TRAU subrack that includes two TRAU unit and provides the following functions: to display the TRAU alarms (4 leds for each TRAU) to connect the TRAU via LMT Evolution connector to exchange alarms to other units via DAISY CHAIN to remote the alarms on the top rack connectors (AW) to switch off the 48 V power supply in the frame by two 4A magnetothermic breakers.

daisy chain

daisy chain

daisy chain

ADAPTER-BOARD

-48B

DC PANEL 0

Fig. 5.10

DC-PANEL system block diagram.

to/from backpanel to backpanel to top rack -48A -48B

-48A

daisy chain

daisy chain

A30808-X3247-M460-3-7631

107

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

LIST OF THE CONNECTORS AND CABLES OF THE FRONT-PANEL BOARD (refer Fig. 5.10). X13-X14 connectors The X13-X14 connectors are used to send alarms (REM-AL-L/R) of the TRAULeft/Right to the top rack (AW connectors) : The type is 26pin, 2x13 pressfit termination. pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Signal BSBK_L/R BSCM_L/R BSMK_L/R N.C. N.C. N.C. N.C. N.C. N.C. OR2BK_L/R OR2CM_L/R OR2MK_L/R N.C. MJBK_L/R MJCM_L/R MJMK_L/R MNBK-L/R MNCM_L/R MNMK_L/R CRBK_L/R CRCM_L/R CRMK_L/R OR1BK_L/R OR1CM_L/R OR1MK_L/R X13,X14 connectors OR alarm pin 14 to 22 Global alarm : Critical Global alarm : Minor Global alarm : Major OR alarm pin 1 to 9 BSC link alarm Description

Tab. 5.10

108

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

REMOTE ALARM CABLE (from DC-Panel: Rem-AL_L/R to RCAP:AW0/(AW7)

Fig. 5.11

Remote Alarms cabling

A30808-X3247-M460-3-7631

109

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

X15-X16 connectors The LMT Evolution connectors X15-X16 are used to have a serial interface of both the TRAU_L/R. The type is D Subminiature straight pressfit termination 15p. Refer to V11 interface for the signals description. pin 1 2 3 4 5 6 7 8 S T(A) C(A) R(A) I(A) S(A) B(A) G X15,X16 connectors of the Front Panel Board Signal 9 10 11 12 13 14 15 pin T(B) C(B) R(B) I(B) S(B) B(B) N.C. Signal

Tab. 5.11

X18 connector The X18 connector is the DA-CH (DAISY CHAIN) connector. The pin description is the same as in the Adapter Board (see Tab. 5.6)

110

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

X17 connector The X17 connector is the LMT+ALM_L/R used for the following signals: Two LMT Evolution serial interfaces for the Trau Left and Right side. Alarm from Backplane : major,minor,critical,external. Alarms to Backplane : power-off,open-door,fan. Power signal from Backplane : +5VA and +5VB. The type is 64pin, 2x32 pressfit termination. Description Signal GND V11 interface for LMT-TRAU-Left side T(A) C(A) R(A) I(A) S(A) B(A) S GND Thermal alarm to BSC_0 PWOFF A0 pin 1 3 5 7 9 11 13 15 17 19 pin 2 4 6 8 10 12 14 16 18 20 Signal GND T(B) C(B) R(B) I(B) S(B) B(B) G GND PWOFF B1 Thermal alarm to BSC_1 V11 interface for LMT-TRAULeft side Description

Tab. 5.12

X17 connectors of the Front Panel Board

A30808-X3247-M460-3-7631

111

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Description

Signal N.C.

pin 21

pin 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64

Signal N.C.

Description

Open door alarm to BSCI-0 of TRAU left Fan alarm to BSCI_0 of TRAU right

OPEND0 23 _L FANAL0 _R N.C. 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63

OPEND1 Open door alarm to BSCI-1 _L of TRAU left FANAL1 _R N.C. N.C. MCR_R GND +5VB_L EXT_L EXT_R GND +5VB_R N.C. T(B) C(B) R(B) I(B) S(B) B(B) G N.C. GND V11 interface for LMT-TRAURight side 5VB TRAU_Right 5VB TRAU_Left External alarm Trau_Left External alarm Trau_Right Critical alarm TRAU_Right Fan alarm to BSCI_1 of TRAU right

Minor alarm TRAU_Right Major alarm TRAU_Right

MN_R MJ_R GND

5VA TRAU_Left Minor alarm TRAU_Left Major alarm TRAU_Left

+5VA_L MJ_L MN_L MCR_L

5VA TRAU_Right

+5VA_R GND

V11 interface for LMT-TRAURight side

T(A) C(A) R(A) I(A) S(A) B(A) S N.C. GND

Tab. 5.12

X17 connectors of the Front Panel Board

LMT+ALM CABLE

X1/X12 connectors (48 V power cabling)

112

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Ref X5 X6 X11 X12 X10 X4 X7 X1 X8 X9 X2 X3 X20

Signal - 48A_UP + 48A_UP - 48B_UP + 48B_UP - 48B_UP - 48A_UP - 48B - 48A - 48B + 48B - 48A + 48A GND from breakers to breakers

Description main power A from Adapter board

main power B from Adapter board

PWR-B to Backplane

PWR-A to Backplane

Tab. 5.13

X1/X12 connectors of the Front Panel Board

DC-CABLES TO BACKPLANE

DC-CABLES TO BREAKERS

A30808-X3247-M460-3-7631

113

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

GROUND CABLES

X19 connector The X19 connector fits the new version TRAUV2 sub-rack (S30861-B248-X) on the TRAU-Standard rack (S30861-C21-X).

114

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

For the pin description see the X7 connector in the Extra Adapter Board (Chap. 5.3).

5.2.3

Internal PCM lines

A30808-X3247-M460-3-7631

115

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

From the Backplane of each FRAME there are two connectors to connect the PCM lines of the TRAU_L/R (left and right) towards and from BSC/MSC.

PCM connector of the TRAU_L

PCM connector of the TRAU_R

Fig. 5.12

PCM lines connectors in DC-Panel

PCM LINES CABLES

116

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

pin 1-20 2-21 3 4-22 5-23 6-24 7-25 26 8-27 9-28 10 11-29 12-30 13-31 14-32 33 15-34 16-35 17 18-36 19-37

signal PCM 0 input PCM 0 output GND PCM 1 input PCM 1 output PCM 0 input PCM 0 output GND PCM 1 input PCM 1 output GND PCM 2input PCM 2 output PCM 3 input PCM 3 output GND N.C. N.C. GND N.C. N.C.

stream from BSC to BSC

from BSC to BSC from MSC to MSC

from MSC to MSC

from MSC to MSC from MSC to MSC

Tab. 5.14

PCM lines connector in the Frame backpanel and in the RCAP

A30808-X3247-M460-3-7631

117

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 5.13

PCM lines wirings

118

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

5.2.4

Photographs of the wiring assembly


This chapter reports the cable routing tables and the photographs of the rack wiring.

Fig. 5.14

Table of the rack wiring

A30808-X3247-M460-3-7631

119

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 5.15

Rack wiring 1

120

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 5.16

Rack wiring 2

A30808-X3247-M460-3-7631

121

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

FRAME 0

Fig. 5.17

Rack wiring 3

FRAME 1

FRAME 2

122

A30808-X3247-M460-3-7631

FRAME 3

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

14/0

14/0

TRAU FRAME 0

4/0A 4/0B

12/0 12/0 18 14/1

14/1

TRAU FRAME 1

4/1A 4/1B

12/1 12/1 18 14/2 14/2

TRAU FRAME 2 4/2A 4/2B 12/2 12/2 18 14/3 14/3

TRAU FRAME 3 4/3A 4/3B 12/3 12/3 18 Fig. 5.18 Rack wiring 4

A30808-X3247-M460-3-7631

123

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Fig. 5.19

Table of the frame wiring

SIGNAL CABLE

Fig. 5.20

Frame wiring 1

POWER CABLES

124

A30808-X3247-M460-3-7631

GROUND CABLE

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

DAISY CHAIN CABLES

Fig. 5.21

Frame wiring 2

REMOTE ALARM CABLES

PCM CABLES

POWER CABLES

A30808-X3247-M460-3-7631

125

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

5.3

TRAU HC Frame to mount in a TRAU Standard rack


It is possible to mount a TRAU HC Frame (S30861-B248-X) in a TRAU Standard rack (S30861-C21-X) by an Extra Adapter Board (S30861-U725-X).

5.3.1

Extra Adapter Board


The Extra Adapter Board is mounted on the Front-Panel-Board (S50201-Q54-X) in the DC-Panel. It provides the following function: to receive - 48VA and - 48VB from the bar of the rack and to power supply the Frame to distribute the Power-off alarm to the Frame to interface the signalling with the other TRAU Frames via DAISY-CHAIN.

LIST OF THE CONNECTORS AND CABLES X3-X4 connectors The X3-X4 are used to receive Power-off alarms from the top of the rack. The type is D subminiature pressfit termination 9 p. pin 1 2 3 4,5,6,7,8,9 Tab. 5.15 signal PWOFFA Thermal alarm A N.C. PWOFFB Thermal alarm B N.C. X3,X4 connectors of the Extra Adapter Board description

126

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

X5-X6 connectors The X5-X6 are used to receive and to distribute the Daisy-Chain alarms and feed the power to the top board (RCAP). The type is D subminiature pressfit termination 9 p. pin 1 2 3 4 5-9 6 7 8 Tab. 5.16 signal N.C GND OPEND + VAB - VAB MJ MN MCR Open-door alarm + 48 V - 48 V Major alarm Minor alarm Critical alarm description

X5,X6 connectors of the Extra Adapter Board

X1-X2 connectors The X1-X2 are used to receive Power supply (X1 from A and X2 from B source). The type is power D subminiature pressfit termination 3 p. pin 1 2 3 Tab. 5.17 signal - VA/B GND + VA/B + 48 V - 48 V description

X1,X2 connectors of the Extra Adapter Board

A30808-X3247-M460-3-7631

127

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

X7 connectors The X7 is used to interface Extra Adapter board to the Frame via front Panel board. . The type is SMT solder terrmination 36 p. description +48 VA +48 VA - 48 VA - 48 VA + 48 VB + 48 VB - 48 VB - 48 VB signal + VA + VA - VA - VA + VB + VB - VB - VB GND Fan alarm FAN GND Open-door alarm OPEND pin 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 pin 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 signal + VA + VA - VA - VA + VB + VB - VB - VB GND PWOFFA Thermal alarm A PWOFFB Thermal alarm B GND MCR MN N.C. N.C. N.C. N.C. Critical alarm Minor Alarm +48 VA +48 VA - 48 VA - 48 VA + 48 VB + 48 VB - 48 VB - 48 VB description

External BSCI alarm (link) EXT Major alarm MJ N.C. N.C. N.C. N.C. Tab. 5.18

X7 connector of the Extra Adapter Board

128

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

The Extra Adapter Board is designed using pressfit connector apart from X7 (Fig. 5.22) that is a SMT solder termination 36 p. This connector needs to connect this board to Front Panel Board (on this board there is the same connector) via a pin strip (V50500C1-A8). Before inserting the finger of the X7 connector in the Front Panel Board connector (DA-CH), tighten the four screws on the Extra Adapter Board to fasten it on the Front Panel Board.

holes for fastening screws

X3

X4

X5 X1 X2 X7

X6

Fig. 5.22

Mechanical layout of the Extra Adapter board

A30808-X3247-M460-3-7631

129

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

AW6

DW6

AW3 S50201-X8-A20 new cables DW3 new cable for expansion subrack

X6

PM2

X5

PM3

X4

X3 X2 X1

GW6

LW6

GW3

LW3

to old type TRAU subrack

Fig. 5.23

Extra Adapter Board system block diagram

130

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 5.24

New subrack of the TRAU_HC in TRAU_standard rack

A30808-X3247-M460-3-7631

131

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

5.3.2

Replacement and expansion procedure


It is possible, in each frame, to replace a TRAU-Standard module with a TRAU-HC module using the TRAU-HC shelf, but if there is another TRAU in service in the shelf below it is allowed to equip only one TRAU (the first on the left side) because of TRAUs cables numbering. If there is no TRAU in the shelf below it is possible to equip both TRAUs of the TRAU-HC frame, provided the number of TRAUs do not exceed four. In the figure below there are some examples of the replace/expansion of TRAU module starting from TRAU-Standard rack with 1, 2 or 3 TRAUs. 0 0 add one TRAU 1 add one TRAU 0 2 1 add one TRAU

0 1 2 3

TRAU-Standard rack with only one TRAU equipped 0 replace with TRAU-HC

add one TRAU 0 1 add one TRAU 1 0 2 add one TRAU 1 3 0 2

0 1 TRAU-Standard rack with two TRAUs equipped 0 1 replace shelf number zero with TRAU-HC shelf add one TRAU 0 1 2 add one TRAU add one TRAU

0 1 2 add one TRAU

0 1 2 3

0 1 2 3

132

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

Fig. 5.25

Examples of replacement and expansion procedures

0 1 2 add one TRAU

0 1 2 3

replace shelf number zero TRAU-Standard rack with three TRAUs equipped 0 1 2 replace shelf 1 number one 2 3 0 add one TRAU 1 2 0

replace shelf number two 0 1 2 add one TRAU 0 1 2 3

Fig. 5.26

Examples of replacement and expansion procedures

A30808-X3247-M460-3-7631

133

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

6 Upgrade Procedure of a TRAU frame in a TRAU HC rack


In the following is showed the Upgrade Procedure of a TRAU frame in a site with TRAU rack already installed and working. The upgrade procedure is referred to one frame only; each frame should be installed in the same way. TRAU rack with a frame missing and cables of the Rack Cabling kit.

Fig. 6.1

TRAU frame wiring

134

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

List of the Rack Cabling kit (S30861-K117-X). Code Number Function Designation Cable Number 14/0 14/0 14/1 14/1 14/2 14/2 14/3 14/3 S50201-X8-A9 Remote Alarm cable 12/0 12/0 12/1 12/1 12/2 12/2 12/3 12/3 S50201-X8-A3 Power cable 4/0A 4/0B 4/1A 4/1B 4/2A 4/2B 4/3A 4/3B S50201-X8-A15 Daisy chain cable ----Connected To Frame 0/X27 (PCM 0) -SX Frame 0/X25 (PCM 1) -DX Frame 1/X27 (PCM 0) -SX Frame 1/X25 (PCM 1) -DX Frame 2/X27 (PCM 0) -SX Frame 2/X25 (PCM 1) -DX Frame 3/X27 (PCM 0) -SX Frame 3/X25 (PCM 1) -DX DC Panel 0/REM AL: - SX DC Panel 0/REM AL: - DX DC Panel 1/REM AL: - SX DC Panel 1/REM AL: - DX DC Panel 2/REM AL: - SX DC Panel 2/REM AL: - DX DC Panel 3/REM AL: - SX DC Panel 3/REM AL: - DX DC Panel 0/PWRA (IN) DC Panel 0/PWRB (IN) DC Panel 1/PWRA (IN) DC Panel 1/PWRB (IN) DC Panel 2/PWRA (IN) DC Panel 2/PWRB (IN) DC Panel 3/PWRA (IN) DC Panel 3/PWRB (IN) DC Panel 0/Daisy chain DC Panel 1/Daisy chain DC Panel 2/Daisy chain DC Panel 3/Daisy chain

S50201-X8-A11 PCM cable

Tab. 6.1

List of Rack Cabling

A30808-X3247-M460-3-7631

135

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

TRAU FRAME (S30861-B248-X) Mechanics (S30861-B250-X)

Fig. 6.2

TRAU FRAME mechanics

DC PANEL (S30861-D26-X)

Fig. 6.3

DC PANEL rear

136

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

FRAME cabling kit

Fig. 6.4

TRAU FRAME cabling

Code Number S50201-X8-A6 S50201-X8-A16 S50201-X8-A16 S50201-X8-A17 Tab. 6.2

Function Designation Ground cable Power cable Power cable Signal cable

From DC Panel/GND DC Panel/PWRA (OUT) DC Panel/PWRB (OUT) DC Panel/LMT+ALARM

To TRAU Frame/X28 (GND) TRAU Frame/X21-X22 (VBA) TRAU Frame/X23-X24 (VBB) TRAU Frame/X26 (LMT+ALM)

List of Frame cabling

A30808-X3247-M460-3-7631

137

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

Upgrade procedure
1 - Mount the frame mechanics

4xScrews Frame-Mechanics

Fig. 6.5

Frame mechanics mounting

2 - Connect ground cable (backplane side)

Fig. 6.6

Ground cable

138

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

3 - Connect PCM cables and Signal cable (backplane side)

Fig. 6.7

PCM and Signal cables

4- Connect power cables (backplane side)

Fig. 6.8

Power cables

A30808-X3247-M460-3-7631

139

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

5 - Mount the DC panel

4xScrews DC-Panel

Fig. 6.9

DC Panel mounting

Make sure that the two breakers of the DC panel are off.

6- Connect Ground cable (DC Panel side)

Fig. 6.10

Ground cable

140

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

7 - Connect Power cables (DC Panel side)

Fig. 6.11

Power cables

8 - Connect Power cables (DC Panel side)

Fig. 6.12

Power cables

A30808-X3247-M460-3-7631

141

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

9 - Connect Remote Alarm cables

Fig. 6.13

Remote Alarm cables

10 - Connect Signal cable (DC Panel side) and Daisy chain cable

Fig. 6.14

Daisy chain and Signal cables

142

A30808-X3247-M460-3-7631

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

12 - Close the DC Panel

Fig. 6.15

DC Panel

A30808-X3247-M460-3-7631

143

IMN:TRAU

Installation Transcoding and Rate Adaption Unit

7 Swap from TRAU Standard rack to TRAU HC rack


To swap the standard rack to HC rack proceed as follows: Disconnect all cables (rst of all: POWER SUPPLY) from the rack and position them in a zone where dont trouble. Take off the standard rack (according the site remove the expansion bolt used for xing the basement, the expansion bolt used for xing the rack to the wall, the Adaption used for securing the rack to the wall - see Chap. 2.5). Install the HC rack according the Chap. 2.6. Reconnect all cables according the site documentation and, if occur, according the Chap. 3 (TRAU Power Supply) and Chap. 4 (External Cabling Activities).

Basement layout
80 (3.15)45 (1.77) 300 (11.8)

160 (6.3) 599 (23.6)

Fig. 7.1

Standard rack drilling sketch

80 (3.15) 45 (1.77)

300 mm (11.8)

57 (2.2)

Basement layout

599 (23.6)

Fig. 7.2

HC rack drilling sketch

144

A30808-X3247-M460-3-7631

300 mm (11.8)

145 (5.7)

300 (11.8)

Installation Transcoding and Rate Adaption Unit

IMN:TRAU

8
A Abis Asub BSC BSS BTS CSU DC ETSI GND HF-DF LMT MDF MSC PCM TFAP TRAC TRX

Abbreviations
GSM Interface between TRAU and MSC GSM Interface between BTS and BSC GSM Interface between BSC and TRAU Base Station Controller Base Station System Base Transceiver Station Channel Service Unit Direct Current European Telecommunication Standards Institute Ground High Frequency-Distribution Frames Local Maintenance Terminal Main Distribution Frame Mobile Switching Center Pulse Code Modulation TRAU Fuse and Alarm Panel Transcoder and Rate Adaption Board Transceiver

A30808-X3247-M460-3-7631

145