Вы находитесь на странице: 1из 2

Networked Access Controller

Rosslares VeritraxTM Networked Access Control System: 32 panels (64 Doors) Control. System of networked HW Controllers & Client/Server Enterprise PC Software.

GENERAL SYSTEM DESCRIPTION


Rosslares VeritraxTM, is a networked access control system for medium scale applications handling up to 10,000 right holding users, and 64 doors. A system may be comprised of up to 32 networked AC-215 Access Control Units (ACUs) driven by Rosslares powerful, flexible and easy to use PC Enterprise software. The VeritraxTM system provides the flexibility of connecting multiple door networks across several communications platforms including RS-485, Ethernet TCP/IP LAN, and PSTN Modem. Each VeritraxTM ACU subnets, consisting of 1 or more ACUs, may be connected to a PC running the VeritraxTM AS-215 Server PC Software for continuous event monitoring, or periodically for batch downloading of event data, administration and maintenance. Other PCs on the network may connect to the server by running the VeritraxTM AS-215 Client PC Software. The system provides an ideal, modular, expandable, and flexible solution for commercial and institutional needs. Veritrax system runs on Microsoft Windows 98/Me and NT/2000/Xp operating systems. It is ideal for an enterprise scale application deployment, utilizing a Client/Server architecture, allows access to multiple local or remote door networks, from multiple PC terminals within a local network.
TM

LED Indicators Ideal for System Inspection and Test Locking Door with Two Keys

Ventilated Side Panel

SECURE Hinged Door for higher anti-vandal resistance

Space for Labelling (Zone and Door Name)

Figure 1. AC-215 Enclosure Hardware


PS-14 Regulated AC/DC Power Supply with Backup Battery Charger Tamper Switch for Housing Closure

AC-215 NETWORKED DOOR CONTROLLER


The VeritraxTM AC-215 ACU is a total solution for the creation of a network of door controllers. Whatever configuration your application requires, VeritraxTM lets you easily design and install a system optimized to suit your needs. Each ACU automatically supports both 1 door (In/Out) and 2 Door (In/Out, In/In and Out/Out) configurations (See Figure 3.). This provides maximum flexibility, and economy on demand. The complete hardware unit (See Figure 2.) is housed in a rugged, hinged metal enclosure that is lockable and tamper protected. The enclosure is compatible with Rosslares PS-14 Power Supply/Charger module, and provides externally visible status LEDs for Power, backup battery voltage status, and power failure. Also included is a special sound unit for audible signals such as alarms, doors reminders and a doorbell. Inside the ACU enclosure, pre-installed components include an AC-AC power transformer, a power supply/charger unit with tabbed battery connectors, a special Bell Unit for audible signals such as alarms, door reminders, and doorbell, the main ACU PCB, space for a Sealed Lead Acid backup battery, and a tamper switch. This means that installation only requires the connection of peripheral keypads/card readers, door strikes/monitors, AC power, and optionally, to a data network. Overall the unit is self contained and ready for installation without the need to source and assemble numerous system parts. This allows you to concentrate your valuable time on designing and installing the system. Single Door 1 Reader
AC to AC Transformer Speaker / Bell Unit for Alarms Wire Strain Releif Mounted AC215Main PCB Wiring Opeining

Sealed Lead-Acid Type Rechargeable Battery

Figure 2. AC-215 Hardware Platform


Single Door 2 Readers Two Door 2 Readers

GLUE-LESS DOOR LOGIC IN NETWORK


The VeritraxTM AC-215 ACU provides seamless integration with Rosslare's range of Proximity Card Readers, PIN keypads, PIN+Prox readers, Smart Card Readers, RFID User Cards and tags. The AC-215 is also compatible with Biometric and Fingerprint readers, Facial and Voice recognition units, and all standard Wiegand 26 or Clock and Data devices.
IN READER IN READER OUT READER IN READER IN READER

Figure 3. AC-215 Configurations

Networked Access Controller Unit


GENERAL DATA << AC-215 >>
Type of Unit: Product Availability: No. of Panels Per Data Line: No. of Doors Per Data Line: No. of Readers/Keypads per ACU: Supported Door Logic: Access Rights User Capacity: Non Access Rights User Capacity: Medium Scale Networked Access Controller Available 1 to 32 1 to 64 (One Door In/OUT or 2 Door In/In) Programmable per reader as IN or Out or None 5000 or 10,000 (w/ MD-16 Memory Upgrade*) 20,000 or 40,000 (w/ MD-16 Memory Upgrade*) Access Control Reader 2 Access Control Reader 1 Input 2 Output 2
Out 2 Out 2 Out 2 In 2 In 2 COM. N.O N.C <-> <+>

ID- 8Way DIP Switch


Speaker (Bell) Out 1 Out 1 Out 1 In 1 In 1 COM. N.O N.C <-> <+>

Connector for Bell Unit

Input 1 Output 1

Off Line ACU History Event Memory: 5000 or 10,000 (w/ MD-16 Memory Upgrade*) Event Memory Retention Power Loss: All System and User settings and Data Non Volatile Local Memory each ACU # Access Levels: # Time Zones (Groups): # Holiday Dates: Compatible Reader Protocols: Anti-Passback (Hard/Soft) Real Anti-Passback: Timed Anti-Passback: Global Anti-Passback: Programmable Auto Relock: Extended Door Unlock Time: Man Trap: First Person Delay: Output Activation: System Alarms: Multiple Facility Codes: Analog/Digital Inputs: 128 32 64 Clock & Data, or Wiegand 26 Bits YES Valid for Two Readers on one ACU Valid on Each Reader (0 to 250 min) YES, Valid on all panels on all networks. YES, Based on Door Monitor or Timer YES, Based on User Definition (Handicapped..) YES, Based on Door Monitor to Enable Reader YES, on Automatic Door Unlock Timed, or Toggled, of Input Follower System registers various alarms. 4-max 4 Inputs - Single Door Configuration: 1) REX, 2) Monitor, 3) Tamper, 4) General Aux 4 Inputs - Two Door Configuration: 1) REX1 2) Monitor1 3) REX2 4) Monitor2 Relay Outputs: 4 Outputs - Single Door Configuration: 1) Lock, 2) Alarm, 3) Aux 4) General Aux 4 Outputs - Two Door Configuration: 1) Lock1, 2) Alarm1, 3) Lock2 4) Alarm2 RS232Communications Direct Wiring INPUT POWER RS485Communications Direct Wiring Input 2A Output 2A
Out 2A COM. Out 2A N.O Out 2A N.C In 2A < - > In 2A <+> Out 1A COM. Out 1A N.O Out 1A N.C In 1A < - > In 1A <+> Rdr. 2 +12Vdc Rdr. 2 - GND D0 D1 Rdr.2 LED Rdr. 2 Tamper Rdr. 1 Tamper Rdr.1 LED D1 D0 Rdr. 1 - GND Rdr. 1 +12Vdc

Input 1A Output 1A

Figure 4. AC-215 Main Controller Board ELECTRICAL DATA << AC-215 >>
ACU Power Supply Voltage: ACU Power Supply Max Current: ACU Maximum Input Current: Max Current for PROX Readers: Max Current for Keypad: Supports Heated Readers: Maximum Current for Lock Strike: 12V DC Regulated - From OEM Power Supply PS-14 500 mA input Current Limited - From OEM Power Supply PS-14 Standby Load: 125 mA @ 12V DC Max Load: 325 mA @ 12V DC 150 mA@ 12V DC for Each Prox Reader 150 mA@ 12V DC for Each Keypad YES, 12 V DC @150 mA ACU Relay Supports up to 30V 5A

COMMUNICATIONS DATA << AC-215 >>


ACU Communications Method: ACU Communications Data Rate: Dial-Up Remote Modem Support: TCP/IP Remote LAN Support: RS-232 / RS-485 Half Duplex 57,600 Bits Per Second YES, Supports Remote Modem Subnet (OEM MD-N33) YES, Supports Remote TCP/IP Subnet (OEM MD-N32)

Max Current for Mag Stripe Readers: 150 mA@ 12V DC for Each Prox Reader

Remote Firmware Upgrade Support: YES, ACU Firmware may be changed by PC: 64 K with Bootstrap Loader and FLASH memory architecture. RS-485 Network Bus Distance (Max): 1200 m Belden Shielded Pairs

INDICATIONS & MMI DATA << AC-215 >>


ACU LED Visual Indicators: 8 - LEDs 1) Data Rx 2) Data Tx 3) Relay Output 1 4) Relay Output 2 5) Relay Output 1A 6) Relay Output 2A 7) Reader 1 Mode 8) Reader 2 Mode (MD-14) PS LED Visual Indicators: 3 - LEDs 1) Input Power 2) Low Battery 3) Power Failure Audible Speaker Connection: Yes, Tones ( Siren, Bell and Chime Reminder) Internal Sound and Tone Generator: Siren Prog.. to Activate on Alarm Events Bell Prog.. to Activate on Selected Input Chime Prog.. to Activate on Access Events Door Monitor and Ajar Warning 8-WAY DIP Switch: 2-Way Switch: Hardware Supervised Readers: Supervised Lock: For ACU Addressing, Type and Baud Rate For Setting RS-485 or RS-232 Reader Tamper Input and Reader LED control Reader Cut Detection Alarms. YES, By Chime, Timer Monitor

ELECTRICAL DATA POWER PCB << PS-14 >>


Requires a Class 2 Transformer: Unregulated AC Input Power: Regulated DC Power Output: Backup Rechargeable Power: (PS-14 ) Auxiliary Power Output: Low Battery Status Monitoring: AC Power Loss Monitoring: Transformer Input 220 / 110 50/60 Hz to 16 Volt AC Output 16 Volt AC (From Transformer) 12 Volt DC with 500 mA current Limit. Yes, Supports 12V Lead Acid (SLA-Type) Rechargeable Cell with on-board Charger PS-14 has 12V/2A for door strike and/or Auxiliary output By Open Collector Output By Open Collector Output VAC

PHYSICAL DATA << AC-215 >>


ACU Board Dimensions [mm] Weight [kg] 102 mmh x 116 mmw x 30 mmd 190g 2.4 KG w/Enclosure 1 Kg PCB 2 Kg + Enc Installation Indoor Installation Only. Recommended Enclosure(mm)Space 200 * 170mm 11 in h 12 in x 3.5 in d

INTERNATIONAL STANDARDS << AC-215 >>


Standards Approvals UL 294 / FCC/ CE CENELEC