A - General technical data Marine Generator - Panda 30 IC PMS Model.: Area of Application.: Generator Version.: Panda 30 IC PMS M (Marine Generator) PMS PSA Premium Line - Panda Standard Asynchronous 50 3000 HP1 27.00 31.8 24.3 28.6 [kW] [kVA] [kW] [kVA] [Hz] [rpm]

Generator Type

Frequency Nominal Speed Alternator Standard Version.: Nominal Performance Nominal Performance Continuous Performance Continuous Performance B - Alternator General Data Power rating factor Cos Pi Voltage Regulation Voltage Tolerance with VCS (up to 80% Performance Generator manufacturer

0.85 VCS 3 FISCHER PANDA accordance with VDE 0875 F MKP Capacitors [Volt]

Shielded to prevent radio interference Isolation class of windings Excitation by

C - Performance Data for electrical Generator (Alternator) Daten HP1 Coil (Single Phase Version) - Standard version Alternator Type "HP1" (High Performance 1 phase Winding), 230 V only. Alternator Type Nominal Voltage in Volt Nominal Performance in kW Nominal Performance in kVA Continuous Performance in kW Continuous Performance in kVA Number of Phases HP1 230 27.00 31.8 24.3 28.6 1 [Volt] [kW] [kVA] [kW] [kVA]

http://www.fischerpanda.de/psadatasheets/eng/1/72/99/277

14.10.2010

Datasheet: Marine Generator - Panda 30 IC PMS | Fischer Panda

Page 2 of 3

Rated current each Phase in Ampere Continuous current each Phase in Ampere Frequency in Hertz

138.3 124.3 50

[A] [A] [Hz]

Daten HP3 Coil (Three Phase Version) - Optional - This version available on request Alternator Type "HP3" (High Performance 3 phase winding). Produces 3-phase current (400 V), but 230 V single phase is included, but must be distributed to 3 phases. Alternator Type Nominal Voltage in Volt Nominal Performance in kW Nominal Performance in kVA Continuous Performance in kW Continuous Performance in kVA Number of Phases Rated current each Phase in Ampere Continuous current each Phase in Ampere Frequency in Hertz HP3 3x400+N 27.00 31.8 24.3 28.6 3 46.0 41.3 50 [A] [A] [Hz] [Volt] [kW] [kVA] [kW] [kVA]

Daten DVS Coil (3 phase + 1 phase Version) - Optional - This version available on request The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The alternator comprises a 3-phase (400V) winding and a 1-phase (230V) winding. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing. DVS Winding - 1 phase Alternator Type Nominal Voltage in in Volt Nominal Performance (P) in kW Nominal Performance (S) in kVA Continuous Performance in kW Continuous Performance in kVA Number of Phases Rated current each Phase in Ampere Continuous current each Phase in Ampere Frequency DVS Winding - 3 phase Alternator Type Nominal Voltage in Volt Nominal Performance (P) in kW Nominal Performance (S) in kVA Continuous Performance in kW Continuous Performance in kVA Number of Phases Rated current each Phase in Ampere Continuous current each Phase in Ampere Frequency in Hertz DVS 3x400+N 23.8 28.0 21.4 25.2 3 40.5 36.4 50 [A] [A] [Hz] [Volt] [kW] [kVA] [kW] [kVA] DVS 230 23.8 28.0 21.4 25.2 1 121.7 109.6 50 [A] [A] [Hz] [Volt] [kW] [kVA] [kW] [kVA]

D - Sound Insulation Cover (generator housing)

Capsule GFK 3D - Standard Sound Insulation Capsule Description Material Sound Insulation Material GFK 3D GFK (Glass fibre reinforced polyester) 3 layers with a total thickness of 30 mm

http://www.fischerpanda.de/psadatasheets/eng/1/72/99/277

14.10.2010

Datasheet: Marine Generator - Panda 30 IC PMS | Fischer Panda

Page 3 of 3

Dimensions Housing

L x W x H *)

Request - Please contact us Request - Please contact us

Total Weight of Generator with Capsule

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc. Therefore please Note You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

E - Engine Data Engine Manufacturer Engine Type No. Cylinders Bore and Displacment Kubota (KU) V 1505 T IC 4 1498 [ccm]

F - Downloads

Disclaimer All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements. Primary Power: Fischer Panda Marine 31.8 kW Generator Fischer Panda Marine 31.8 kW Genset Fischer Panda Marine 31.8 kW Power Generator Fischer Panda Marine 31.8 kW Diesel Generator Fischer Panda Marine 31.8 kW Electric Generator Keywords:

Impressum | Kontakt | AGB | Garantiebedingungen | Inhaltsbersicht

2010 Fischer Panda GmbH

Certificate Registration No. 476591 QM08

http://www.fischerpanda.de/psadatasheets/eng/1/72/99/277

14.10.2010

Вам также может понравиться