As an energy supplier or consumer, you need to manage the quality and cost of your energy. It's important to lower operational costs, support complex billing structures, and keep your systems running without interruptions.
ION enterprise energy management systems are the answer. They deliver energy information and control from everywhere, to everywhere, you need.
ION products communicate over global networks, integrate with existing systems, and match your exact needs. Applications include power quality management, energy cost control, operations management, billing support, distributed generation, and more.
en
t era
or
Gene
rato
r B
ION 7700
ION 6200
REVENUE METERING
Real-time pricing and interruptible service support Sub-metering
ADVANCED PROCESSING
Virtual meters (VIP) customized for any set of functions Math, logic, trig, log, linearization formulas
INFORMATION MANAGEMENT
Graphic user interface: default and custom displays with animation Report generation: energy and demand, load profile, power quality Multi-site data collection, aggregation, and real-time display Continuous or scheduled retrieval of metered data Company-wide data access through networked PCs Web-enabled access ODBC-compliant database for historical data logging DDE interface for data exchange with other applications Remote meter configuration and firmware upgrades Windows 2000, Windows NT, and Windows 98 operating systems
TCP/IP over Ethernet Modbus RTU and Modbus/TCP Continuous, scheduled, or event-driven communications WebReach for web browser display
ION 6200
POWER, ENERGY, and DEMAND
ION 7300
! ! ! !
ION 7330
! ! ! !
ION 7350
! ! ! ! !
ION 7500
! ! ! ! !
ION 7600
! ! ! ! ! !
ION 7700
! ! ! ! ! !
ION 8300
! ! ! ! ! !
ION 8400
! ! ! ! ! !
ION 8500
! ! ! ! ! !
Voltage/current: per phase, average, unbalance* Power: real, reactive, apparent, power factor, frequency Energy: bi-directional, total, import, export, net* Demand: block, rolling block, thermal, predicted*
POWER QUALITY ANALYSIS
! ! ! !
Sag/swell monitoring Symmetrical components: zero, negative, positive Transient detection, microseconds Harmonics (individual, even, odd, total) up to Sampling rate, maximum samples/cycle Flicker, harmonics to EN50160, IEC 61000-4-7 / 4-15 Configurable for IEEE 519-1992, IEEE 1159, SEMI Number of nines uptime data (6 nines=99.9999%)
DATA and WAVEFORM LOGS
THD 64
15th 32
15th 32
31st 64
63rd 128
65 63rd 256
! !
31st 128
63rd 128
65 63rd 256
! !
! ! ! ! ! ! ! ! ! !
! ! ! ! ! ! !
! ! ! !
! ! ! !
! ! ! !
Triggered by setpoint, schedule, or external signal Sequence-of-event logs, variable log depth Minimum/maximum logs for any parameter Historical logs, maximum # of channels Waveform logs, maximum # of consecutive cycles Timestamps, resolution in seconds GPS time synchronization
COMMUNICATION PORTS and I/O (maximum #)
32 0.001
96 48 0.001
800 96 0.001
!
800 96 0.001
!
320 96 0.001
!
32 0.001
!
320 0.001
!
800 96 0.001
!
ION Enterprise
Single-workstation or networked analysis, control, and data management Customize displays with graphs, diagrams and animation
RS-232/485 ports RS-485-only ports Ethernet ports Infrared optical ports LonWorks ports (LonTalk support) PROFIBUS ports Built-in modems Modbus RTU Slave on serial, modem, infrared ports** Modbus RTU Master on serial ports Modbus/TCP on Ethernet ports DNP 3.0 on serial, modem, infrared ports EtherGate: 31 other meters accessible via RS-485 ModemGate: 31 other meters accessible via RS-485 MeterM@il : data emailed from meter WebMeter : on-board web server Analog inputs** Analog outputs** Digital status/counter inputs** Digital relay outputs (control/pulse)**
1 1 1 1 1
! !
2 1 1
2 1 1
1 1 1 1
1 1 1 1
1 2 1
1 1 1 1
1 1 1 1
1 1 1 1
1
! ! ! ! ! ! ! ! !
1
! ! ! ! ! ! !
1
! ! ! ! ! ! ! !
1
! ! ! ! ! ! ! !
1
!
1
! !
1
! ! ! ! ! ! ! !
1
! ! ! ! ! ! ! !
! ! !
! ! ! ! !
4 4 2 4
4 4 4 4 1 sec
! !
4 4 4 4 1 sec
! ! !
1
4 4 16 7
/2
4 4 16 7
1
18 30 38 30 1 cycle
! ! !
4 8 8 1 sec
! ! ! !
1
4 8 8
/2
4 8 8
1
SETPOINTS, ALARMING, and CONTROL Automatically generate and distribute power quality and energy reports
Setpoints, minimum response time Math, logic, trig, log, linearization formulas Single- and multi-condition alarms Call-out on alarm Dial-out on outage
REVENUE METERING
cycle
! ! !
/2
cycle
! ! !
cycle
! ! ! ! ! ! ! ! ! ! ! ! ! !
/2
cycle
! ! ! ! ! ! ! ! ! ! ! ! ! !
ANSI C12.16 accuracy compliant ANSI C12.20 0.2 compliant IEC 60687 0.2S compliant IEC 60687 accuracy class 0.5S compliant ANSI class 10 (5A nominal, 10A max) ANSI class 2, IEC 1/10 (1A nominal, 10A max) ANSI class 20, IEC 5/20 (5A nominal, 20A max) MV-90 on serial, Ethernet ports Measurement Canada approved Multi-year scheduling: hourly activity profiles Transformer/line loss compensation
*Not all functions available for all meters.
! ! ! ! !
! ! !
! ! ! ! ! ! ! ! ! !
! ! !
! !
! !
! ! !
! !
! ! !
! ! ! ! !
! ! !
! ! ! !
! ! ! !
! ! ! !
ION Enterprise
ION 7700
ION 6200
Power Measurement has a long history of providing enterprise energy management systems to power suppliers and consumers around the globe. Our real-time information and control systems manage the quality, reliability, and cost of energy. All products are supported by training programs, engineering services, a worldwide network of sales professionals, and uncompromising customer support.
Worldwide Headquarters
Tel: 1-250-652-7100 Fax: 1-250-652-0411 email: sales@pwrm.com Toll free 1-866-466-7627
866-ION-SMART
www.pwrm.com
Contact Power Measurement for detailed specifications and ordering information.
ION, ION Enterprise, VIP, ION 6200, ION 7300, ION 7330, ION 7350, ION 7500, ION 7600, ION 7700, ION 8300, ION 8400, ION 8500, MeterM@il, WebMeter, EtherGate, ModemGate, Feature Packs, and smart energy everywhere are either registered trademarks or trademarks of Power Measurement. All other trademarks are the property of their respective owners. Information contained herein is subject to change without notice. Revision Date: October 2002 2002 Power Measurement Printed in Canada 70200-0127