The Oriental Insurance Company Ltd.

Oriental Staff Training College Sector -11 Mathura Road Faridabad -121006

Tender Document
NAME OF WORK: SUPPLY, INSTALLATION ,TESTING &
COMMISSIONING OF HIGH WALL TYPE SPLIT/ DUCTABLE SPLIT/WINDOW TYPE AIR CONDITIONING UNITS & ELECTRICAL WORKS AT `

# Oriental Staff Training College At Sector 11 FARIDABAD

Lead Consultants:
Vastu Mandal Architects & Interior Designers F-328, Lado Sarai, New Delhi-110030 Ph 41665455 Fax 41665455 E-Mail vastumandal@bol.net.in vastumandal@gmail.com

PART II FINANICIAL BID

Page 0

1.01 Preamble to Bill/ Schedule of Quantities 1 All items of work under this Contract shall be executed strictly to fulfill the requirements laid down under Basis of Design in the specifications. Type of equipment, material specification, methods of installation and testing and type of control shall be in accordance with the specifications, approved shop drawings and the relevant Indian Standards, however capacity of each component and their quantities shall be such as to fulfill the above mentioned requirement. 2 The unit rate for all equipment or materials shall include cost in RUPEES for equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractors store at site, storage, installation, testing, balancing, commissioning and other works as required. 3 The rate for each item of work included in All materials, fixing materials, Wastage on materials and labour. Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary for the full and entire execution. Liabilities, obligations and risks arising out of Conditions of Contract. All requirements of Specifications, whether such requirements are mentioned in the item or not. The Specifications and Drawings where available, are to be read as complimentary to and part of the Bill of Quantities and any work called for in one shall be taken as required for all.

In the event of conflict between Bill of Quantities and other documents including the Specifications, the most stringent shall apply. The interpretation of the Architect/HVAC Consultants/Owner shall be final and binding.

Page 1

4 All equipment, quantities and technical data indicated in this Schedule are for the Contractors guidance only, these are based on the documents prepared by the Architect/HVAC Consultant. The Contractor shall be paid for the actual quantity of work executed by him in accordance with the approved Shop/Construction Drawings at the contract rates. 5 This Schedule shall be fully priced and the extensions and totals duly checked. 6 No alteration whatsoever is to be made to the text or quantities of this Schedule unless such alteration is authorized in writing by the Architect /HVAC Consultant. Any such alterations, notes or additions shall unless authorized in writing be disregarded when tender documents are considered. 7 In the event of an error occurring in the amount of the Schedule as a result of wrong extension of the unit rate and quantity, the unit rate quoted by the bidder shall be regarded as firm and the extensions shall be amended on the basis of rates. 8 Any error in totaling in the amount column and in carrying forward the total shall be corrected. Any error in description or in quantity omission of items from this Schedule shall not vitiate this Contract but shall be corrected and deemed to be variation required by the Architect/HVAC Consultant. 9 The Contractor shall procure and bring Material/Equipment to the site only on the basis of drawings approved for construction and shop drawings and not on the basis of Bill of Quantities, which are approximate only. This also applies to the Contractors requisition for Owner supplied materials. 10 All Control cabling & wiring required to make the system complete shall be treated as part of equipment, panels etc. and nothing extra shall be payable on this account.

Page 2

BILL OF QUQNTITIES A Air Coditioning Works S. No. Description Units 1.00 Air-cooled Ductable Type Split Units Sets comprising of: 1 x Indoor Unit, 3.0 TR Nominal Capacity complete with filters, evporator cooling coil, fan with motor & drive arrangement, power & control componets with wiring. 1 x 3.0 TR nominal capacity air cooled condensing unit complete with hermetically sealed reciprocating compressor, multi row deep air cooled condenser coil, condenser fan with motor & drive, controls, power & control componets with wiring as required. Standard Installation of above split AC units including copper refrigerant piping with fittings, nitrile rubber insulation & wiring - up to 10 Rmt for each compressor to interconnect the condensing units with the indoor units including gas charging, testing & commissioning Initial charge of refrigerant and oil. Electronic remote control unit Fire Retardant Duct Flexible Connectors at outlet complete with fittings, flanges, supports, all accessories as per specifications and any other item required to make the system complete. Refrigerant: R-22 MS Angle Iron Stands and vibration isolation for mounting the outdoor units. The stands shall be painted with 2 coats of red oxide primer and 2 coats of synthetic enamel paint. Power Supply: Single Point Power Supply within 1 metre of outdoor unit, 415V, 3 Phase, 50 Hz, 4 Wire Cost shall be inclusive of minor masonry work e.g. making openings in walls and slabs for passing ducts, pipes,cables, etc. and finally sealing and finishing them good. 2.00 Air-cooled Hi wall Type Split Units comprising of: 1 x Indoor Unit of Nominal Capacity as shown below complete with filters, evporator cooling coil, fan with motor & drive arrangement, power & control componets with wiring.

Qty. 2

Rate (Rs )

Rate (words)

Amount

Page 3

S. No. Description Units 1 x air cooled condensing unit of nominal capacity complete with hermetically sealed rotary compressor(s), multi row deep air cooled condenser coil, condenser fan with motor & drive, controls, power & control componets with wiring. as required. Hi wall split shall be energy efficient of BEE Label 3 Star rating Standard Installation of above split AC units including copper refrigerant piping with fittings, nitrile rubber insulation & wiring - up to 10 Rmt for each compressor to interconnect the condensing units with the indoor units including gas charging, testing & commissioning Initial charge of refrigerant and oil. Electronic remote control unit Refrigerant: R-22 MS Angle Iron Stands and vibration isolation for mounting the outdoor units. The stands shall be painted with 2 coats of red oxide primer and 2 coats of synthetic enamel paint. Supply, installation, testing & commissioning of Voltage Stabliser of approved make installed near outdoor unit complete with its weather protection arrangement Power Supply: Single Point Power Supply within 1 metre of outdoor unit, Single Phase, 50 Hz, 3 wire Cost shall be inclusive of minor masonry work e.g. making openings in walls and slabs for passing pipes,cables, etc. and finally sealing and finishing them good. Capacity 2.0 TR Capacity 1.5 TR

Qty.

Rate (Rs )

Rate (words)

Amount

2.01 2.02

Sets Sets

10 4

2A.00 Air-cooled Slimline Tower Type Split Units comprising of: 1 x Indoor Unit of Nominal Capacity as shown below complete with filters, evporator cooling coil, fan with motor & drive arrangement, power & control componets with wiring. 1 x air cooled condensing unit of nominal capacity complete with energy efficient hermetically sealed compressor(s), multi row deep air cooled condenser coil, condenser fan with motor & drive, controls, power & control componets with wiring. as required.

Page 4

S. No. Description Units Standard Installation of above split AC units including copper refrigerant piping with fittings, nitrile rubber insulation & wiring - up to 10 Rmt for each compressor to interconnect the condensing units with the indoor units including gas charging, testing & commissioning Initial charge of refrigerant and oil. Electronic remote control unit Refrigerant: R-22 MS Angle Iron Stands and vibration isolation for mounting the outdoor units. The stands shall be painted with 2 coats of red oxide primer and 2 coats of synthetic enamel paint. Power Supply: Single Point Power Supply within 1 metre of outdoor unit, 415V, 3 Phase, 50 Hz, 4 Wire Cost shall be inclusive of minor masonry work e.g. making openings in walls and slabs for passing pipes,cables, etc. and finally sealing and finishing them good. 2A.01 Capacity 3.0 TR 3.00 Window type Airconditioners Supply, installation, testing & commissioning of window type air-conditioners complete with Electronic remote control unit of following capacities. The unit shall be complete with frame for fixing. The gaps if any between existing window and the AC Casing shall be filled with high density foam/Neatley finished wood frame painted in enamel matching the colour of Aluminum window complete as / directions Sets

Qty.

Rate (Rs )

Rate (words)

Amount

Window Airconditioners shall be energy efficient of BEE Label 2 Star rating Supply, installation, testing & commissioning of Voltage Stabliser of approved make 3.01 3.02 4.00 Capacity 1.5 TR Capacity 1.0 TR Extra route length beyond 10 Rmt for copper refrigerant piping with fittings, nitrile rubber insulation & wiring to interconnect the condensing units with the indoor units including gas charging, testing & commissioning. 1 Rmt shall mean distance between the indoor unit and outdoor unit measured along the route of the refrigerant piping minus 10 m, irrespective of number of refrigeration circuits. For 3.0 TR Ductable/ Slimline splits For 2.0 TR Hi Wall splits Sets Sets 37 4

4.01 4.02

Rmt Rmt

15 45

Page 5

S. No. Description 4.03 For 1.5 TR Hi Wall splits 5.00 uPVC High Pressure Drain Water Piping complete with fittings (elbows, tees, reducers, sockets etc.), supports, jointing, nitrile rubber insulation etc. and any other item required to make the system complete. Nominal Diameters in mm as indicated below: 5.01 32 5.02 25 5A.00 Supply,installation,testing and commissioning of centrifugal type air curtains of Mitzwah/ Beacon/ Almonard make of robust construction. The casing shall be of MS with powder coated fininsh. The impeller shall be of aluminium construction having forward curved leaves. Impeller shall be with single phase 230V,50Hz sturdy motor for continous operation. Air curtain shall be complete with vibration isolation,elecrtical cord with plug,other accesories to malke the system complete.The unit shall be for following door sizes 5A.1 Door width 5 ft 5A.2 Door width 4 Ft Air Distribution 6.00 Supply, Installation, Testing & Commissioning of GSS Ducting complete with fittings, flanges, bracings, supports, all accessories as per specifications and any other item required to make the system complete. 6.01 24 G 6.02 22 G 6.03 Supply, Installation, Testing & Commissioning of Extruded Aluminium Square/ Rectangular/ Round Air Diffusers with volume control dampers complete with mounting arrangement, wooden/ steel/ aluminium frame work (if required), all accessories as per specifications and any other item required to make the system complete. 6.04 Supply, Installation, Testing & Commissioning of Extruded Aluminium Square/ Rectangular/ Round Air Diffusers without volume control dampers complete with mounting arrangement, wooden/ steel/ aluminium frame work (if required), all accessories as per specifications and any other item required to make the system complete.

Units Rmt

Qty. 15

Rate (Rs )

Rate (words)

Amount

Rmt Rmt

50 120

Set Set

1 1

Sqm Sqm Sqm

45 5 1

Sqm

Page 6

S. No. Description 6.05 Supply, Installation, Testing & Commissioning of Extruded Aluminium Rectangular Grilles with volume control dampers complete with mounting arrangement, wooden/ steel/ aluminium frame work (if required), all accessories as per specifications and any other item required to make the system complete. 6.06 Supply, Installation, Testing & Commissioning of Extruded Aluminium Rectangular Grilles without volume control dampers complete with mounting arrangement, wooden/ steel/ aluminium frame work (if required), all accessories as per specifications and any other item required to make the system complete. 7.00 Supply, Installation, Testing & Commissioning of Duct Acoustic Insulation with in various ducts complete with all accessories & finishes as per specifications and any other item required to make the system complete. 7.01 Supply, Installation, Testing & Commissioning of 25 mm thick Resin Bonded Fiber Glass. 8.00 Supply, Installation, Testing & Commissioning of Duct Thermal Insulation on various ducts using cross linked polyethylene complete with all accessories and finishes as per specifications and any other item required to make the system complete. 8.01 6 mm thick 9.00 Fresh air/Exhaust air louvers made of extruded aluminimum complete with HDPE insect mesh and mounting frames as required. 10.00 Heavy duty volume control dampers 11.00 Painting of all exposed ducting and grilles of approved shade in baked enamel to match the interiors ( This item shall be paid on the basis of exposed duct surface area )

Units Sqm

Qty. 2

Rate (Rs )

Rate (words)

Amount

Sqm

Sqm

15

Sqm Sqm

Rate only 1

Sqm Sqm

1 45

Total ( Air Conditioning Works ) NOTE The work shall be done by the authorised dealer of any approved make.

Page 7

S. No. Description

Units

Qty.

Rate (Rs )

Rate (words)

Amount

B 1

Electrical Works AC DB-1 Supply Installation, testing and commissioning of mainAC panel comprising of the following :Incomer 1 No. 125A TPN MCCB, 25kA (Ics=Icu), suitable for motor duty with thermal overload releases; magnetic short circuit release and earthfault release, auxiliary contacts, extended type handle with door interlock and padlock facility. 1 No. 0-125A CT operated type Ammeter with selector switch, 3 Nos. 125/5A. 15VA class I CTs. 1 No. 0-500 V voltmeter with selectorswitch & control fuses. 3 Nos. Phase indicating lamps with control fuses. Bus bar Bus bar 200A 433V Three Phase 4 wire colour coded non-adhesive PVC insulated electrolytic `Al' conductor bus bar. Outgoings 6 Nos. 32A DP MCB. 2 Nos. 25A DP MCB. 2 Nos. 16A 4P MCB.

1 Set

AC DB-2 Supply Installation, testing and commissioning of mainAC panel comprising of the following :Incomer 1 No. 63A TPN MCCB, 25kA (Ics=Icu), suitable for motor duty with thermal overload releases; magnetic short circuit release and earthfault release, auxiliary contacts, extended type handle with door interlock and padlock facility. 1 No. 0-125A CT operated type Ammeter with selector switch, 3 Nos. 125/5A. 15VA class I CTs. 1 No. 0-500 V voltmeter with selectorswitch & control fuses. 3 Nos. Phase indicating lamps with control fuses.

1 Set

Page 8

S. No. Description

Units

Qty.

Rate (Rs )

Rate (words)

Amount

Bus bar Bus bar 200A 433V Three Phase 4 wire colour coded non-adhesive PVC insulated electrolytic `Al' conductor bus bar. Outgoings 4 Nos. 32A DP MCB. 1 Nos. 25A DP MCB. 2 Nos. 16A 4P MCB. Supply, installation, testing & commissioning of 1.1 KV cable with circular stranded compacted aluminium conductor, conductor screen, XLPE insulation, insulation screen, PVC tape bedding, steelwire armoured overall PVC sheathed as per IS:7098 Part II. 2 2.1 2.2 2.3 2.4 2.2 3 1/2C X 35 sq.mm. A2XFY 100 Mtrs. 100 Mtrs. 300 Mtrs. 500 Mtrs.

4C X 25 sq.mm. A2XFY 4C X 4 sq.mm. YWY 3C X 6 sq.mm. YWY Supply and installation of cable end termination for 1.1 KV grade cables using brass double compression cable glandsand aluminium/copper thimbles withmanual/hydraulic crimping method(Aluminium thimbles for aluminiumconductor cables and copper thimbles forcopper conductor cables will be used). sq.mm. A2XFY

2.2.1 3 1/2C X 35 2.2.2 4C X 25 2.2.3 6C X 4 2.2.4 3C X 6 3 3.1

2 Nos. 2 Nos. 12 Nos. 20 Nos.

sq.mm. A2XFY sq.mm YWY sq.mm YWY

Switch & sockets. Supply and installation of 32A 240V 3-pin interlocked switched socket unit suitable for surface mounting box IP66 WITH din RAIL & with decorative finish as approved by Owner. Make -Legrand.

10 Nos.

Page 9

S. No. Description Units Qty. 6 Nos. 3.2 Supply and installation of 32A 415V 3-pin interlocked switched socket unit suitable for surface mounting box IP66 WITH din RAIL & with decorative finish as approved by Owner. Make -Legrand. Total Electrical Works GRAND TOTAL RS Air Condition Works + Electrical Works Total Amount in Words

Rate (Rs )

Rate (words)

Amount

Contractors Signature

Contractors Name

Contractors Seal

Page 10