Specifications Of The Building THE COTERIE @ HOLLAND (10 August 2011)
1. 2. 3. FOUNDATION RC foundation / RC piles to Engineers specifications SUBSTRUCTURE & SUPERSTRUCTURE Reinforced concrete framework. WALLS (a) External Walls (b) 4. 5. ROOF Flat Roof CEILING (FOR APARTMENT) (a) (b) ( c) 6. Living, Dining, Bedrooms, Study, Balcony Master Bath, Common Bath and Kitchen Internal Staircase (for Penthouse only) : : : Skim coat with emulsion paint Fibrous board with emulsion paint Skim coat with emulsion paint : Reinforced concrete roof with waterproofing system Internal Walls

: :

Common clay bricks and/or dry wall Common clay bricks and/or concrete blocks and/or dry wall

FINISHES COMMON AREAS (a) Internal Walls (i) (ii) (iii) (iv) (v) (b) (c) 1st Storey Lift Lobby Typical Lift Lobbies Corridors Staircases Carpark : : : : : Imported ceramic tiles and/or cement & sand plaster with emulsion paint finish Imported ceramic tiles and/or cement & sand plaster with emulsion paint Cement & sand plaster and/or skim coat with emulsion paint finish Cement & sand plaster and/or skim coat with emulsion paint finish Cement & sand plaster and/or skim coat with emulsion paint finish Cement & sand plaster and emulsion paint Imported ceramic and/or homogenous tiles Imported ceramic and/or homogenous tiles Imported ceramic and/or homogenous tiles Cement & sand screed Cement & sand screed

External Walls (i) Floor (i) (ii) (iii) (iv) (v) External Walls 1st Storey Lift Lobby Typical Lift Lobbies Corridors Staircases Carpark : : : : : :

6.

FINISHES APARTMENT (a) Walls (i) (ii)

Cement & sand plaster with emulsion paint Imported ceramic tiles and/or compressed marble laid up to false ceiling height and exposed surface only (iii) : Imported ceramic tiles laid up to false ceiling height and on exposed surface only Note: No tiles/stone works behind kitchen cabinet/vanity cabinet/mirror

Living, Dining, Bedrooms & Study Master Bathroom & Common Bathroom Kitchen

: :

For Internal Use Only ; Not for Circulation

SPECIFICATIONS
(b) Floor (i) Living, Dining & Bedrooms (For Type A1G, A1, A2G, A2 Only) (ii) Master Bedroom, Bedroom 2 (For Type B1G, B1, B2G, B2 and Penthouse Unit Only) Study (For Penthouse Unit Only) Bathrooms Kitchen Private Staircase (For Penthouse Unit Only) Roof Terrace, Balcony, Open Terrace Planter, A/C Ledge : : Compressed marble and/or homogenous tiles Timber flooring

(iii) (iv) (v) (vi) (vii) (viii) 7. WINDOWS (a)

: : : : : : :

Timber flooring Imported ceramic tiles and/or compressed marble Imported Ceramic tiles Timber flooring Imported Ceramic tiles Cement & sand screed Aluminum framed window with fixed glass panels, sliding and/or casement windows.

Bedrooms, Bathrooms, Kitchen Note : (a) (b) (c)

All aluminum frames shall be powder coated finish All glazing shall be approximately 6mm thick clear or tinted glass All glazing below 1m shall be of tempered or laminated glass : : : : Approved fire rated timber door Aluminum framed sliding door Swing or Sliding Timber door Timber door or Sliding door

8.

DOORS (a) Main Entrance Door (b) Living/Dining (c) Bedrooms (d) Bathrooms Note : (a) (b) (c)

All aluminum frames shall be powder coated finish All glazing shall be approximately 6mm thick Door can be of either swing or sliding type

9. 10

IRONMONGERY (a) All timber doors shall be provided with good quality imported locksets SANITARY FITTINGS (a) Master Bathroom : : : : : : : : : : : : : : 1 pedestal water closet 1 basin 1 basin mixer Frameless glass shower cubicle complete with shower mixer 1 toilet paper holder 1 mirror 1 pedestal water closet 1 basin 1 basin mixer 1 frameless glass shower cubicle complete with shower mixer 1 toilet paper holder 1 mirror 1 single mixer 1 kitchen sink

(b)

Common Bathrooms

(c)

Kitchen

For Internal Use Only ; Not for Circulation

SPECIFICATIONS
11 ELECTRICAL SCHEDULE (a) Concealed electrical wiring in conduits below false ceiling level. Electrical wiring above false ceiling shall be in exposed and/or concealed conduits and/or trunking. (b) Refer to Electrical Schedule for details. TV / TELEPHONE Refer to the Electrical Schedule for details. LIGHTNING PROTECTION Lightning protection system shall be provided in accordance to Singapore Standard CP33:1996 PAINTING (a) Internal Wall : Emulsion paint (b) External Wall : Emulsion paint WATERPROOFING Waterproofing to floors of Bathrooms, Kitchen, Roof Terrace, RC flat roof and Planters. DRIVEWAY AND CAR PARK (a) Surface Driveway & Carpark : Concrete floor and/or ceramic and/or stone finish RECREATION FACILITIES (a) Swimming Pool (b) Pool Deck (c) Wading Pool (d) Spa Corner (e) Open Gymnasium (f) BBQ Pit (g) Childrens Playground ADDITIONAL ITEMS (a) Wardrobes (b) Kitchen cabinet and Appliances : : Built-in wardrobes to Bedrooms Built-in high and low level kitchen cabinets, cooker hob & hood, refrigerator, built-in oven (For Type B1G, B1, B2G, B2 and Penthouse Unit Only) and microwave oven (For Type A1G, A1, A2G and A2 Only). Air conditioning split system provided to Living/Dining &Bedrooms Hot water supply to Bathrooms Audio Intercom based on Purchasers private telephone line from apartment to gate only Galvanized steel auto gate Brick wall with emulsion paint and or BRC fencing

12 13 14

15 16 17

18

(c) (d) (e) 19

Air-Conditioning Water Heater Audio Intercom

: : :

GATE AND FENCING (a) Gate (b) Boundary Wall

: :

For Internal Use Only ; Not for Circulation

SPECIFICATIONS
Notes: (i) Marble, Limestone and Granite Marble, limestone and granite are natural stone materials containing veins with tonality differences. There will be colour and markings caused by their complex mineral composition and incorporated impurities. While such materials can be pre-selected before installation, this non-conformity in the marble, limestone or granite as well as nonuniformity between pieces cannot be totally avoided. Granite tiles are pre-polished before laying and care has been taken for their installation. However granite, being a much harder material than marble, cannot be re-polished after installation. Hence some differences may be felt at the joints. Subject to Clause 14.3, the tonality and pattern of marble, limestone or granite selected and installed shall be subjected to availability. Timber Timber as a natural material containing grain/vein and tonality differences. Thus it is not possible to achieve total consistency of colour and grain in its selection and installation. Cable Television and/or Internet Access The Purchaser is liable to pay annual fee, subscription fee and such other fees to the StarHub Cable Vision Ltd (SCV) and/or internet services providers (ISP) or any other relevant party or any other relevant authorities. The Vendor is not responsible to make arrangements with any of the said parties for the service connection for their respective subscription channels and/or internet access. Fitting, Equipment Finishes, Installations and Appliances Subject to Clause 14.3, the brand, colour and model of all materials, fittings, equipment finishes; installations and appliances supplied shall be provided subject to Architects selection, market availabilities and the sole discretion of the Vendor. Wardrobes, Kitchen Cabinets, Fan Coil Units and Electrical Points, Door Swing Positions and Plaster Ceiling Board layout/location are subject to Architects sole discretion and final design. Air-Conditioning System To ensure good working condition of the air-conditioning system, the system has to be maintained and cleaned by the Purchaser on a regular basic. This includes the cleaning of filters, clearing the condensate pipes and charging gas. DESCRIPTION OF HOUSING PROJECT General Description PROPOSED ERRECTION OF A BLOCK OF 12 STOREY RESIDENTIAL FLAT DEVELOPMENT (TOTAL 36 UNITS) WITH A SURFACE AND MECHANICAL CARPARK AND SKY TERRACE ON 2ND STOREY WITH PROVISION OF SWIMMING POOL ON LOT 02662W MK 02 AT HOLLAND ROAD (TANGLIN PLANNING AREA) Detail of Building Specifications Refer to the Building Specifications in the First Schedule hereto.

(ii)

(iii)

(iv)

(v) (vi)

For Internal Use Only ; Not for Circulation

SPECIFICATIONS
Types of Residential Units Located in the Building Project Type Type A1-G Type A2-G Type B1-G Type B2-G Type A1 Type A2 Type B1 Type B2 Type A1-P Type A2-P Type B1-P Type B2-P No of Units 1 1 1 1 7 7 7 7 1 1 1 1 Storey 3 Storey 3 Storey 3 Storey 3rd Storey 4th 10th Storey 4th 10th Storey 4th 10th Storey 4 10 Storey 11th 12th Storey 11th 12th Storey 11th 12th Storey 11th 12th Storey
th th rd rd rd

Description of Common Property Swimming Pool Pool Deck Wading Pool Spa Corner Open Gymnasium BBQ Pit Childrens Playground

Description of Parking Spaces 24 Mechanical Car Park Lots (Dimension for Car Size 5.2m(L) x 2.15m(W) x 2.00m(H)) 13 Surface Car Park Lots (Inclusive of 1 Handicapped Car Park Lot)

Purpose of Building Project and Restrictions to Use The building project is strictly for residential occupation only. Common Area 1. 2. No Guard House is provided No Management room is provided