Вы находитесь на странице: 1из 12

Solar Collector Test Report

A Report to:

Your Solar Home, Inc. 299 Applewood Cr., Unit 4 Vaughan, ON L4K 4E7

Attention:

Todd Kirkpatrick, President

Telephone: Fax:

905-669-2212 905-669-2204

Report No.:

07-08-9195 3 Pages, 2 Appendices

Date:

January 14, 2008

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Page 2 of 3 Report No. 07-08-9195

1.0

INTRODUCTION This report documents Uniform Positive and Negative Load testing of two air-heating solar collectors for Your Solar Home, Inc. Testing was done in accordance with Section 6.2.5 of CAN/CSA Standard F378-87 Solar Collectors. The National Solar Test Facility is operated by Bodycote Testing Group for Natural Resources Canada.

2.0

SAMPLE DESCRIPTION Bodycote Sample Number: Manufacturer Name: Collector Model: Serial Number: Collector Type: General Construction: Cover Plate: Dimensions: Gross (including PV Section): Collector Aperture: PV Section Aperture: Heat Transfer Fluid: Bodycote Sample Number: Manufacturer Name: Collector Model: Serial Number: Collector Type: General Construction: Cover Plate: Dimensions: Gross (includes PV Section): Collector Aperture: Heat Transfer Fluid: 07-08-9195-1 Your Solar Home, Inc. 1500 G 01-000211 Flat plate, air-heating, PV panel section attached at top Aluminum extrusion frame, aluminum back sheet Clear glass 2.210 m length x 1.154 m width1; Area: 2.550 m 1.784 m length x 1.010 m width; Area: 1.802 m 0.270 m length x 1.010 m width; Area: 0.273 m Air 07-08-9195-2 Your Solar Home, Inc. 1500 GS n/a Flat plate, air-heating Aluminum extrusion frame, aluminum back sheet Clear glass 2.208 m length x 1.097 m width; Area: 2.422 m 2.121 m length x 1.010 m width; Area: 2.142 m Air

Includes width of the reinforcement extrusions provided by Your Solar Home, Inc.

Bodycote Testing Group Solar Collector TestReport for YourSolar Home,Inc. Page3 of3 ReportNo. 07-08-9195

3.0

UNIFORM POSITIVE AND NEGATIVE LOAD TEST PROCEDURE The Uniform PositiveandNegativeLoad testswere donein accordance with Section6.2.5of CAN/CSA-F378-87"Solar Collectors". The two collectortypestestedare intendedfor surface and rack mounting,and were thereforetestedfor both typesof installation. Testpressure differentialsusedwere + 1.5kPa, -0.5 kPa and -2.0 kPa, in that order. Acceptance criteria for this test arecontainedin Section5.6.2 of the Standard. The 15000 model was first reinforced(by Bodycotestaff) with two 19" long aluminum extrusionsprovidedby the Client, and in accordance with the instructionsin the "Add-On Reinforcement Kit" amendment the Solarsheat to 10000/15000 installationmanual(version2.2) providedby the Client. Both collector samples their associated and mountinghardwarewere assembled per the as installationmanualprovidedby Your SolarHome, Inc., andthen attached turn to the loadtest in table.

4.0

TEST RESULTS after testing. Therewas no apparent permanent distortion of eithertest sampleobserved

5.0

CONCLUSIONS
BodycoteSamples 07-08-9195-1 07-08-9195-2 and both passedthe CSA-F378-87 Positiveand NegativeLoad Testsat the pressures specifiedfor surface-mounted for rack-mounted and collectors.

Reportedby:

Reviewedby:

d~,fi{~
Technologist
National SolarTest Facility

f~ Technical Manager AdDr.~H'P.Eng.


.

National SolarTest Facility

This report refers only to the particular samples, units, material, instrument, or other subject used and referred to in it, and is limited by the tests and/or analyses performed. Similar articles may not be of like quality, and other testing and/or analysis programs might be desirable and might give different results.

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix A Report No. 07-08-9195

APPENDIX A
Bodycote Sample 07-08-9195-1 Test Forms Test Photos (3 Pages)

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix A, Page 1 of 3 Report No. 07-08-9195

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix A, Page 2 of 3 Report No. 07-08-9195

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix A, Page 3 of 3 Report No. 07-08-9195

Figure 1: Side view of collector below test enclosure.

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix B Report No. 07-08-9195

APPENDIX B
Bodycote Sample 07-08-9195-2 Test Forms Test Photos (4 Pages)

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix B, Page 1 of 4 Report No. 07-08-9195

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix B, Page 2 of 4 Report No. 07-08-9195

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix B, Page 3 of 4 Report No. 07-08-9195

Figure 1: Overall view of positive/negative load test apparatus (excluding blower).

Figure 2: Side view of collector showing mounting bracket and attachment to load test table.

Bodycote Testing Group Solar Collector Test Report for Your Solar Home, Inc. Appendix B, Page 4 of 4 Report No. 07-08-9195

Figure 3: Top view (enclosure cover removed) showing tape seal around edges.