Вы находитесь на странице: 1из 4

Cycet

Electronic Prepaid meter


Directly Charge Usage Energy

- Hi Safety, Hi Security, Hi Accuracy - No Hi voltage danger at user point - Allowance over limit programmable - Easy installation & Easy application - No management software or programming devices required - Anti fraud auto OFF when activated - 1Phase & 3Phase available

APPLICATION
- Shared residential apartment - Condominium - Campus dorm - Mobile home park - Senior high school HVAC usage. - Food session energy counting - Shopping center sub meter - Exhibition booth sub meter

OVERVIEW
DEM510 single phase two wire meter DEM600 three phase four wire meter The IC card metering system has been successfully used in university dorm as well as shared residential apartment for many years. The system lets you give your customers a choice by prepaid before they use electric power. With this prepaid meter, theres no need to read meters every month and eliminated human error in reading and data manipulation as well as money collection and bad debt. The IC card unit installed in the room will display exactly how much electricity power they're using and how much cash still available to use. So the Users effectively manage their electricity power consumption as well as their budgets.

BENEFIT
For you and your client can either eliminate or reduce 1)Collections 2)Meter reads 3)Calls 4)Bills, deposits and disconnect fees 5)Service actions 6)Hassles 7) Electric power limit

CONSTRUCTION
The Prepaid meter consists of 3 parts 1) Meter the DEM series The meter DEM series is digital microprocessor unit of kwh metering with internal switch functionality within one single compact enclosure. It is usually installed in a secure, locked electric distribution panel. DEM series has many models to choose from single phase two wire and 3 phase 4 wire. 2) Card reader ICR815 The ICR is a compact unit for clients operation interface with IC card slot as well as a friendly LED display. It is usually installed in a convenient location in consumers home-remote or room or site ICR815 card reader unit is connected to the meter DEM series with a communication cable type CAT#5 plug-in cable. 3) Programming unit ICR815W Programming Unit, this is card programming that installed at services provider, Using this unit to program or renew the user card to active again.

Cycet
Electronic Prepaid meter
Directly Charge Usage Energy BENEFIT FOR USER AND SERVICES PROVIDER
FOR SERVICES PROVIDER While the utility cost is charged and additional of house rental fee charge method is not only non economic but also unfair. At least, that could not provide incentive to User for energy saving, even more, it could encourage the User waste their electricity. Finally, the house rent must be raised to compensate the waste and this higher rent will cause the services provider lost theirs rental competition. Our pay as you go meter provides a simple and cost effective solution for property manager. FOR USER The User ca easily monitor their electricity usage so as to control their budget to use. Since the room rate exclude the electricity cost, that will allow the User pay less on total rental cost if they willing to save more energy.

HOW IT WORKS? FOR USER Operation simple The User should purchase the a card from service counter, after inserting this card into their individual ICR815 room unit, the electricity power is coming and the ICR815 will automatic deduct electricity cost from the card until amount is used up. The User can easily read the outstanding value and also update kwh to monitor meter's kWh from the card reader ICR815 room unit. When the cash in IC card amount used up, the meter will shutdown the power later (*). That will force the User to buy a new card to get electricity power again. This pay as you go metering system is very similar using calling cards, that is quite simple and reliable.

The manager can set credit period at ICR815 to extend up to 200 hours, that allowed Users have time to prepare new card. So as to prevent theirs power being interrupted

Key Card
For services provider to set each card reader ICR815 to be the same family group.

User Card
The User buy from services provider and insert to card reader ICR815.

Cycet
Electronic Prepaid meter
Directly Charge Usage Energy FOR SERVICES PROVIDER
The services provider can sell the smart card or user card just like selling calling card. That can ensure all electricity revenue won't be lost and also simplify the administrative works. The services provider or manager will never need any jobs like before that need to do metering, meter reading or billing and money collection and so on, as well as eliminating related tedious tasks.. Services provider also can offer a IC card value added machine by ICR815W or beautiful card collections. The services provider can use it for value added operations, By utilizing this unit, the property manager also can set up the IC card amount and tariff per kwh after a key card being inserted and verified successfully.

MORE ADVANCED FEATURE


Low value alert As long as there is amount on the IC card, consumption is enabled and when value is below a certain limit, called low value, the consumer is warned by beeper and flashing lamp to notice the User to prepare a new card within a certain period... If new card is not loaded, meter's internal relay will automatically switch off while the used up.

SIMPLE INSTALLATION
The DEM series meter and ICR815 card reader always installed together. To avoid the hi voltage risk to user then card reader ICR815 came in this picture and use to install in the room or user point for user access. kwh meter is separately installed from IC card room unit to take care the hi voltage part. Normally, DEM meters are installed at a centralized meter panel and ICR815 room unit is installed at individual room. Using a standard cat #5 cable to connect between them. Installation is simple and requires no special training. ICR815 room unit do not need extra power supply, it direct get its power from DEM meter itself. This advanced design eliminates the extra power wiring labor and cost. After installation is complete, using a key card to initialize each ICR815. Since then, the ICR815 will only accept the User card which generated by this key card family.

Credit Period
Credit period is also available for user as the optional setting. This special period can be loaded up to 240 hours (max.) During credit period, the relay will maintain closed and all the consumed data is stored. Until the next new User card is insert, it will be auto deduct the value from this new card.

Fraud Detection
Whenever the meter system detects attempts of fraud, the relay is switched off to shutdown power.

Operation Flow Chart

Cycet
Electronic Prepaid meter
Directly Charge Usage Energy

PRODUCT SPECIFICATION
METER Model: DEM510 single phase two wires DEM540 single phase three wires DEM600 three phase three wires DEM600 three phase four wires Voltage rating: DEM510: 230V AC; 50Hz/60Hz DEM540: 110/220VAC; 50Hz/60Hz DEM600(3p3w):220V; 50Hz/60Hz DEM600(3p4w):220/380V; 50Hz/60Hz Current range: 10(40)A Display: DEM510: 6 digits counter and load on/off status DEM540: 6 digits LED and load on/off status DEM600: 6 digits LED and load on/off status KWH meter constant:3200 imp/kwh Impulse voltage withstand: 6KV Starting current: 40mA Accuracy class: per IEC 61036 CALSS 1 Internal relay contractor : 50A continuous Protection feature: Relay is auto shut off when meter can not detect the ICR815 Connection port: RJ45 socket to link to ICR815 by cat#5 Cable Power consumption: 3 W/ 5 VA Seals: termination seals are provided Operating humidity : up to 90% RH Storage temperature :-30C to +70C Operating temperature: -20C to +55C Dimensions /Weight : DEM510:154mm x 110mm x 61mm :800 gram DEM540: 180mm x 125mm x 62mm :1000 gram DEM600: 220mm x 145mm x 70mm :1600 gram ICR815 USER ROOM IC CARD UNIT Display: 6 digits LED with function legend display Key: 1 switches Display function: IC card remain value, kwh reading, error code, communication status Initialization: Insert the key card to initialize ICR815 while installation completed. Mounting: Surface mount Seals: Protection seals is provided to prevent authorized personnel to access internal circuit IC card standard : ISO 7816 Power Consumption : 3 W/ 5 VA Operating Humidity : up to 90% Storing Temperature : -30C to +70C Operating Temperature : -20C to +55C Dimensions : 150mm x 110mm x 35mm Weight : 300gram

ICR815W IC CARD PROGRAMMING UNIT Programming: Unique key card to unlock programming function Setting: 1)set amount and tariff to User IC card 2)set low value and renew credit period on key card Display: total number of card has been successfully being programmed. User interface: 2 lines by 16 characters LCD display with 2 keys Speed: 1sec. after the User card is insert and a beep to notice value added successfully. Operating Temperature : -20C to +55C Dimensions : 150mm x 110mm x 35mm Weight : 300gram

USER IC CARD Customer logo silk screen printing: one color is available at extra charge

Вам также может понравиться