Вы находитесь на странице: 1из 4

ATL / 2011 30 August, 2011

// PROFORMA INVOICE //

Viatsa Email: vtl_murthal@yahoo.com Kind Attn: Mr. Anil Chawala Dear Sir, Sub: Analytical Technologies HPLC System We would like thank you very much for your email inquiry regarding your requirement for HPLC System please find our Proforma Invoice for the same.

I.

Analytical Technologies Isocratic HPLC System: Sr.No. Description Analytical Technologies HPLC System with variable Wave Detector & necessary accessories, Consisting of: 01. Analytical Technologies Isocratic Pump Specification Delivery method : double pistons, main & auxiliary Pump head :10 ml SS/Bio analytical ,upgradable to 50ml, 100ml,250ml,500ml,1000ml by exchangeable heads Maximum working pressure: 10 ml pump head 42 Mpa for SST/30 Mpa for PEEK. Flow Range : 10 ml pump head 0.001-9.999ml/min Flow rate accuracy : 0.5% measurement at 1ml/min Display : 320 X 240 blue background colour Protection : Pmax& Pmin Data automatically saved after Power down System connection: 1/16 capillaries Control : Stand-along mode by front keypad HPG Mode: one pump work as master, Others work as slave. RS232 by PC using communication protocol Power Supply : AC220V, 50Hz,400W Dimensions and weight: 410 x 180 x 270 x 10 kg. 02. Analytical Technologies UV-VIS Variable Wave Detector Detector Wavelength Range: 190nm-900 nm - Wavelength Precision: <0.1nm - Wavelength accuracy: <0.3nm Optional bandwidth: 6nm Rise time: 0.0s-9.9s - Baseline noise: <0.5x10-5 AU (empty cell, 254nm, time: 60min) Flow cell: Analytical flow cell: optical path length 10mm: volume 10uL semi-preparative flow cell: optional path length 3mm; volume 5uL Light source: Deuterium lamp & Tungsten Power: AC 110V/220V, 50Hz/60Hz Consumption: 110W Dimensions: 420mm x 280mm x 175mm 03. Analytical Technologies Manual Injector with Automatic Start Qty. 1 Set 1 Price in INR

1 Contd2/-

Analytical Technologies Limited (An Iso 9001Analytical Group Co.) Corporate & Reg. Office: Analytical House, E67 & 68, Ravi Park, Opp. Sainath Park, Vasna Road, Baroda,Gujarat390015, INDIA. Tel: 0091- 265-2253620, 3208026, 3252840 Telefax: 0091-265-2254392 Email: info@ais-india.com, info@hplctechnologies.com, info@analyticalgroup.net Web: www.ais-india.com / www.analyticalgroup.net Sales & Support Offices: across the country; Distributors & Channel partners World Wide.

// 2 // Sr.No. Description 04. Analchrom 21 CFR/FDA complaint Chromatography Station for 32-bit windows Chromatography software for data acquisition and data processing SW Package: SW on a CD, HW key (dongle), cables, manuals, A/D converter (optional) A/D converters: Proprietary only internal PCI, external USB, TCP/IP Operating systems: Microsoft Windows 2000, XP, any localization, MS Vista 32bit (Compatibility table refer to datasheet D016) PC Requirements: Refer to datasheet D016 Compatibility Table for further information. Number of connected instruments: Up to 4 chromatography/ Instruments (= up to 4 time basis) at a time each up to 12 signals/ channels Data acquisition: Any detector with voltage output: up to 10m distance using USB and PCI converters or through Ethernet using the Net PDA for data acquisition from distant places Digital acquisition: for selected chromatographs, e.g. Agilent, Knauer, etc. (Refer to datasheet D004 The list of controlled instruments). Measuring ranges: Bipolar: 156, 1250, 10000mV, Integration frequency: up to 400 Hz, 24-bit resolution GLP / 21 CFR Part 11 requirements: Password protection / expiration, Electronic signature, Audit Trails, User Accounts with access rights, raw data and history of modification stored in chromatogram, Validation Co-operation with autosamplers: The software cooperates with all autosamplers in active or passive mode by synchronization on TTL signal level. Direct control of selected autosamplers is available (refer to The list of controlled instruments, code D004) Integration: 27-integration parameter, such as Peak Width, Threshold, Tangent Slope Ratio, etc. Integration parameters are programmable in Time, automatic reintegration. Calculation types: Both without and with calibration (internal and external standard methods), parameters of individual peaks for assessing both the Efficiency of the column and the chromatographic system as a whole,

Qty. 1 Set

Price in INR

Contd3/-

Analytical Technologies Limited (An Iso 9001Analytical Group Co.) Corporate & Reg. Office: Analytical House, E67 & 68, Ravi Park, Opp. Sainath Park, Vasna Road, Baroda,Gujarat390015, INDIA. Tel: 0091- 265-2253620, 3208026, 3252840 Telefax: 0091-265-2254392 Email: info@ais-india.com, info@hplctechnologies.com, info@analyticalgroup.net Web: www.ais-india.com / www.analyticalgroup.net Sales & Support Offices: across the country; Distributors & Channel partners World Wide.

Sr.No.

// 3 // Description SST module for establishing deviations and reproducibility of selected parameters Calibrations: 6 types of calibration curves, up 20 levels, Reference Peaks, Groups, unlimited number of standards (peaks), LOD, LOQ Work with chromatograms: Overlay of unlimited number of chromatograms, mathematical operations with. Chromatograms, custom labels and setting for chromatograms Automation: Sequences, Post Run automatic launching of selected commands and applications immediately after the chromatogram acquisition, Batch processing, command line parameters Presentation of results: Result and Summary Tables, both integrated and customizable, columns with user-defined calculation, export in text or database format Calculations: Custom: 12 predefined mathematical operators, 15 basic and summary functions Special: Kovats indexes, noise / drift determination Reports: Custom protocol Layouts, Print Preview, Print to PDF file, E-mail report Data export: ASCII, AIA, dBase, LIMS Data import: ASCII, AIA, LIMS Multi-user environment: Selectable system of user accounts with independently customizable behavior and appearance for individual users Network environment: Easy off line (At the file level) data sharing among all stations in a local network Control modules: Refer to datasheet D004 The list of controlled instruments Extensions: GPC, PDA, CE, EA, Installation qualification (IQ) Test, Validation Kit, SST module, LIMS Interface Separate Solutions: Clarity Lite, Clarity Offline refer to datasheet D007 for feature

Qty.

Price in INR

Contd4/-

Analytical Technologies Limited (An Iso 9001Analytical Group Co.) Corporate & Reg. Office: Analytical House, E67 & 68, Ravi Park, Opp. Sainath Park, Vasna Road, Baroda,Gujarat390015, INDIA. Tel: 0091- 265-2253620, 3208026, 3252840 Telefax: 0091-265-2254392 Email: info@ais-india.com, info@hplctechnologies.com, info@analyticalgroup.net Web: www.ais-india.com / www.analyticalgroup.net Sales & Support Offices: across the country; Distributors & Channel partners World Wide.

// 4 // Sr.No. Description Comparison OEM version upon request Support, Warranty: Automatic update from Web, free software updates, free access to online knowledge database, on line technical support, 3 years hardware warranty Column C18, 250mm x 4.6mm x 5um Accessories a) External sample loop 20ul SS: 1 b) SS Mobile Phase Filter 2um, 1/8: 1 c) Accessories like tubing, nuts, ferrules, fittings etc. : 1 set Total Ex-works Price Less: Special Discount 25% After discounted ex-works Price Qty. Price in INR

05 06

1 1 set

7,50,000.00 1,87,500.00 5,62,500.00

TERMS & CONDITIONS: 01. Price : Ex- works Baroda 02. Validity : 30 Days 03. Delivery : 4-8 weeks on receipt of your order & Advance Payment 04. Octroi : As applicable 05. Vat : 5% 06. Excise will be charged at Actual. 07. Packing, forwarding & handling Charges: 3% 08. Air Freight, Insurance: 4% 09. Payment : 100 % advance payment by means of Bankers Draft drawn or Irrevocable L/C In favour of Analytical Technologies Limited, Baroda Thanking you and looking forward to the pleasure of supporting your Quality Control and Research activities by supplying our products, technologies and Services. Yours sincerely, For ANALYTICAL TECHNOLOGIES LIMITED (An Iso 9001 Analytical Group Co.)

Smital Patel Biomed Co-ordinator Email: biomed@hplctechnologies.com www.analyticalgroup.net www.ais-india.com

Analytical Technologies Limited (An Iso 9001Analytical Group Co.) Corporate & Reg. Office: Analytical House, E67 & 68, Ravi Park, Opp. Sainath Park, Vasna Road, Baroda,Gujarat390015, INDIA. Tel: 0091- 265-2253620, 3208026, 3252840 Telefax: 0091-265-2254392 Email: info@ais-india.com, info@hplctechnologies.com, info@analyticalgroup.net Web: www.ais-india.com / www.analyticalgroup.net Sales & Support Offices: across the country; Distributors & Channel partners World Wide.

Вам также может понравиться