Вы находитесь на странице: 1из 4

QUANTUM® Q1000 Electronic

Multimeasurement Meter
Maximize your Measurement Intelligence

Unsurpassed Accuracy Registered Quality B.V. Calibration


QUANTUM Q1000 provides you with the Laboratory and NMi Netherlands
information to deliver energy predictably Meetinstitute; in Mexico: Comision /Federal
and reliably. This revolutionary meter De Electricidad and LAPEM; in Argentina:
meets worldwide requirements for INTI; in Spain: Red Electrica De Espana; in
accuracy, reliability, and connectivity. France: Electricite De France.
The information technology and
standards are all based on our The Q1000 meter is available in Socket,
experience with proven QUANTUM Rackmount, Switchboard, DIN, A-base, and
meter engineering. DIN Flushmount configurations. Each
configuration is available in form five [3
The SchlumbergerSema QUANTUM phase 3 wire delta, (2 element)] and form
Q1000 is a solid-state electronic nine [3 phase, 4 wire wye (3 element)].
multimeasurement, transformer-rated,
polyphase meter of unsurpassed Flexible Communications
accuracy designed to be used at bulk QUANTUM Q1000 works the way you
power flow points, including power work, featuring flexible input and output
plants, substations, intertie points, and capabilities and a wide range of software
large commercial and industrial sites. options. The QUANTUM Q1000 is equally
The Q1000 meter measures and displays versatile in multiple high speed
The QUANTUM Q1000 communications, from frame relay and
the per phase real and reactive power in
meter is available in fiber optics to radio, phone, dial-up, and
all four quadrants along with thousands
socket, rackmount, of other values. microwave using DNP 3.0, IEC 60870-5-102,
switchboard, DIN, and IEC 60870-5-102 plus, mini-DLMS, and
A-base configurations. Active transformer technology combined MODBUS® protocols.
with a 14-bit analog-to-digital converter
reduces measurement errors to near Protocols.
reference standard levels. Each Q1000 The Q1000 meter has powerful, flexible
meter meets or exceeds the accuracy protocols, enabling you to connect to a
standards for IEC 60687 for 0.2S and variety of systems.This flexibility allows
ANSI C12.20: 1997 for class 0.2 meters. easy coordination with existing systems.

The Q1000 has been tested and Dependable Support


approved by many internationally SchlumbergerSema backs QUANTUM
recognized laboratories in conjunction Q1000 with the reliable support you
with local utilities. Among these are: in expect from the leading solutions
the United States: California ISO, New provider to electric utilities. Our engineers
England ISO, Texas ISO-ERCOT, and work with you to implement the
Demand Side Solutions, Inc.; in Canada: QUANTUM Q1000 in the field and tailor
Measurement Canada, Ontario IMO, and its software to provide the intelligent,
Subnet Solutions; in Netherlands: KEMA real-time information you need.
QUANTUM® Q1000 Electronic Multimeasurement Meter

Key Features The Q1000 meter is capable of


calculating, recording, and displaying Standard Features
• Class 0.1% accuracy the following registers: • Class 0.1% Accuracy
• Optical communication port, two • 7 Rate TOU
Energy
RS-232 communication ports, and • Flexible User Memory
I/O port can be used simultaneously • Wh: net, delivered, received, per • Quad-Port Communications (QDIP,
• Up to ten load profiles with 24 phase, and aggregate mini-DLMS protocols included)
• VARh: delivered, received, 4-quadrant,
channels each enabling a variety of • 1 Load Profile (24 channels)
per phase, and aggregate
interval length choices for energy • 32 I/O Capability (supports one module of
• VAh: vectorial and arithmetic, 4-quadrant,
quantities each type - purchase separately.)
delivered, received, per phase,
• TOU • System Loss Compensation
aggregate, distortion, and unbalance
- Current (active) Schedule • 1 Splitter Communications Cable
• PFh: per phase and aggregate
- Latent (pending) Schedule • Hzh • Additional options are: AC/DC Auxiliary
- Seven day types • Qh: net, delivered, and received Power, Meter Form, Optical Port Type,
- Seven rates plus total • Ih and I2h: per phase, neutral, and LED Type, Operating Frequency, and
- Many daily patterns average Current Class Rating.
- Many switch points • Vh and V2h: per phase and average
- Up to 16 digital state triggered • Ih: per phase, % THD, ANSI, and
TOU events IEC versions Optional Features
- Up to 12 independent seasons • Vh: per phase, % THD, ANSI, and • Digital state inputs and outputs
per year IEC versions • KY/KYZ digital pulse inputs and outputs
- Many years • Energy values are programmable for • Voltage and current analog outputs
- Many holidays per phase and three phase data • Support for advanced protocols,
- Supports simultaneous active TOU including DNP 3.0, IEC 60870-5-102,
Demand
rates (overlapping) IEC 60870-5-102 Plus, and
- Supports temporary overrides of Maximum and minimums, present,
MODBUS (RTU) protocols
Current TOU Schedule previous, projected, cumulative,
• Hardened internal 33,600 bps modem
continuous cumulative, and selectable
• Advanced Protocols DNP 3.0, option board
coincident demand values
MODBUS RTU • Autoranging AC/DC auxiliary power
• Reconfiguration Demand Register Types supply
- Communication • Hardened 4 wire RS-485/RS-232
• Block and rolling demand intervals
- Daylight Savings Time with programmable interval and option board
- Harmonics subinterval lengths.
- Input Configuration • Thermal demand calculations I/O Network
- LED Operation • Demand intervals are synchronized to • The I/O modules are separate and complete
- Security Codes the internal clock. modules. Each module interfaces to the
- Voltage Quality • Demand values are programmable meter through a twisted pair of wires
- Current Time of Use for per phase and three phase data. utilizing Echelon's LonWorks® protocol.
- Latent Time of Use • The Q1000 plug and play meters can be
• System loss compensation (SLC) Instantaneous configured to use the following functions
• Update meter time +/- one hour • Net, delivered, received, per phase, through the use of I/O modules:
independently of other meter and aggregate - 8 pulse outputs
functions • Instanteneous peaks and minimums - 8 pulse inputs
• GPS time synchronization - 16 digital state outputs
Self Read
• Detection and recording of voltage - 16 digital state inputs
Up to 32 sets of self read data, each set
sags, swells, imbalances, and - 8 analog outputs
with up to 60 registers.
interruptions - 8 analog inputs(1)
• Detection and measurement of
Voltage Input Ratings
2nd to 32nd harmonics with
recording of and display 2nd Meter Rated Voltage Table
to 20th harmonics Form 5 {3 phase, 3 wire delta (2 element)] Phase to Phase Voltage
• Splitter cable that separates Socket
I/O wires (2); two RS-232 com ports
58-69V* 100-120V 220-240V
(DB-25 connector, each);
RS-485 com port wires (5) DIN/DIN Flushmount/A-base/Switchboard/Rackmount
• Eight totalized quantities 58-69V* 100-120V 220-240V
(additive, subtractive, and Form 9 [3 phase, 4 wire wye (3 element)] Phase to Neutral Voltage
SQRT sum-of-the-squares) Socket
• Flexible user memory
58-69 V* 100-120V 220-240V
DIN/DIN Flushmount/A-base/Switchboard/Rackmount
58-69V 100-120V 220-240V*
2
* Meters operating within these ranges are only available when ordered with auxiliary power.
QUANTUM® Q1000 Electronic Multimeasurement Meter

Accuracy Data • Voltage Range: -20% to +25% of


The Q1000 meter is a +/-0.1% accuracy device complying with the requirements of IEC 60687 nominal voltage
(1992-06) for 0.2S meters and ANSI C12.20:1997 for class 0.2 meters. • Frequency Range:
Measured Quantity Phase Angle % Error of Reading 57-63 Hz (60 Hz setting)
Volts (0.75Vn-1.15Vn) All Phase Angles +/- 0.2% 47-53 Hz (50 Hz setting)
• Temperature Range: -40˚C to +85˚C
Amps (0.1A-0.25A) All Phase Angles +/- 0.4%
• Humidity Range: 0 to 95%, non-
Amps (0.25A-5A) All Phase Angles +/- 0.2% condensing
Watts (0.05A-0.25A) 0˚, 180˚ +/- 0.2%
Watts (0.25A-20A) 0˚, 180˚ +/- 0.1% Reference Conditions for Accuracy Data
Watts (0.1A-0.5A) -60˚, +60˚, -120˚, +120˚ +/- 0.3% • Voltage: nominal voltage +/- 3%
• Current: In to class amps
Watts (0.5A-20A) -60˚, +60˚, -120˚, +120˚ +/- 0.2%
• Temp: +23˚C +/-3˚C
Vars (0.05A-0.25A) -90˚, +90˚ +/- 0.2%
• Frequency: As rated (50 or 60 Hz)
Vars (0.25A-20A) -90˚, +90˚ +/- 0.1% • Waveform: Distortion factor
Vars (0.1A-0.5A) -30˚, +30˚, 150˚, +150˚ +/- 0.3% less than 3%
Vars (0.5A-20A) -30˚, +30˚, 150˚, +150˚ +/- 0.3%
Q(0.05A-0.25A) -60˚ +120˚ +/- 0.4%
Q(0.25A-20A)
Q(0.1A-0.5A)
-60˚ +120˚
-30˚, +30˚, 150˚, +150˚
+/- 0.3%
+/- 0.6%
Reference Information
• QUANTUM ® Q1000 Meter Technical
Q(0.5A-20A) -30˚, +30˚, 150˚, +150˚ +/- 0.4%
Reference Guide, Revision 2.0
VA Arith. (0.05A-0.25A) All Phase Angles +/- 0.3% • QUANTUM ® Q1000 Online
VA Arith. (0.25A-20A) All Phase Angles +/- 0.4% Technical Reference Guide
VA Vec. (0.1A-0.5A) -60˚, +60˚, -120˚, +120˚ +/- 0.3% • PC-PRO+® 98 Getting Started Guide
-30˚, +30˚, -150˚, +150˚ • PC-PRO+® 98 Help Files
VA Vec. (0.5A-20A) -60˚, +60˚, -120˚, +120˚ +/- 0.3% • Protocol Editor™ Help files
-30˚, +30˚, -150˚, +150˚ • Protocol Editor™ Getting Started Guide

• The quantities, pulse weights, events,


demand, and zero offset are user Product Availability Technical Data
programmable. Hardware Mounting General International Codes:
• Standard system supports a 500 foot I/O • Q1000 Socket: Form 5, Form 9 Conforms to:
Network. Call for longer distances. • Q1000 DIN: Form 5, Form 9 • ANSI C12.1: 1995
(1)
This module is not yet available. • Q1000 Switchboard: Form 5, Form 9 • ANSI C12.20: 1998
• Q1000 Rackmount: Form 5, Form 9 • ANSI/UL 50:1992
Internal Modem • ASTM B117:1994
• Q1000 A-base: Form 5, Form 9
• 33,600 bps modem • Q1000 DIN Flushmount: Form 5, Form 9 • ASTM D999:1991
• Auto-baud sensing capability • IEC 60687 (1992-06)
• Can be configured as either an Current Input Ratings • IEC 60068-2-6 (1995-03)
auto-answer or an auto-dial unit • ANSI Class 10, ANSI Class 201 • IEC 60068-2-27 (1987-06)
• Off-hook detect allows modem to release • IEC In=5A, Imax=10A • IEC 61268
phone line if extension phone picks up • IEC In=5A, Imax=20A1 The Q1000 meets ANSI C12.1 with the exception of
• Supports up to 32 meters on one phone • ANSI Class 22 Section 4.7.2.8 “Meter Losses” and section 4.7.2.13
line “Radio Frequency Conducted and Radiated
• IEC In=1A, Imax=6A2
Emission.”
1
Rackmount meter available in 10A and low
Advanced Protocols
current ranges. Surge, Impulse, and RF Interference
• DNP 3.0, Level 2+ • IEC 60870-5-102+ 2
Low current version available in Socket, Rackmount,
Conforms to:
• IEC 60870-5-102 • MODBUS® RTU Switchboard, DIN, DIN Flushmount and A-base Forms.
• ANSI C37.90.1: 1989
Auxiliary Power Ratings • ANSI C62.41: 1991
Software 1 phase AC or two wire DC 100-240V • FCC Part 15
• FCC Part 68
• Compatible with ITRON® MV-90
• IEC 61000-4-2 (1995-01)
• PC-PRO+® 98
• Protocol Editor™ Specifications • IEC 61000-4-4 (1995-01)

• HHF meter data file creation with • Current Range: 0 to class amps Accuracy Tests
PC-PRO+ 98 version 5.0 or greater • Test Amps: 0.5 class amps In conformance with the IEC 60687
• EnergyAudit™ 5.0 • Starting Current: standard for class 0.2S meters, as well
• Compatible with DC Systems RTscada™, 1A meters: <1mA as ANSI C12.16 for class 0.2 meters
for real-time applications 10A meters: <5mA
20A meters: <5mA
3
Dimensions
All dimensions are in centimeters and (inches)

Q1000 Socket Meter Q1000 Rackmount Meter

Q1000 A-Base Meter

Q1000 Switchboard Meter

Q1000 DIN Meter (with short cover)*

* Long cover available

SchlumbergerSema SchlumbergerSema
Energy & Utilities Energy & Utilities
313-B North Highway 11 6700 Century Avenue, Suite 100
West Union, SC 29696, USA Mississauga, Ontario L5N 2V8
Tel: (864) 638-8300 Canada
Fax: (864) 638-4950 Tel: (905) 812-2227
Fax: (905) 812-5028
© 2002 SchlumbergerSema Inc.

www.goslb.com
Effective Date: July 2002
GTD-Q1K-0066-07.02
QUANTUM and PC-PRO+ are registered trademarks and Protocol Editor is a trademark
of SchlumbergerSema Inc. LONWORKS is a trademark of Echelon Corporation.
MODBUS is a trademark of Proticon. RTscada is a trademark of DC Systems.

Вам также может понравиться