Вы находитесь на странице: 1из 4

Circulating Fluidized Bed

for Coal Fired Boiler

WWW.V-FLO.COM

TEL:+8610 88580010/51906628
FAX:+8610 88580150

V-FLO

5th Floor East, Jiahuiyuan, Huaao Center,


No.31 Zizhuyuan Road, Haidian District, Beijing, China

Circulating Fluidized Bed for Coal Fired Boiler


Features
Burning efficiency reaches 95%99%. high burning rate, heat efficiency above 87%.energysaving, high efficiency.
High flexibility of fuel, which can satisfy the burning of many kinds of fuels.

formulates sulphate, desulphuration can satisfy environment protection. reasonable air


distribution and low temperature of furnace, which can control formulation of NOx and really
reach environment protection. big adjusting range load can be adjusted rang 110%30%.
High automatic control, makes boilers running safely and economically in long term.
Adopt upper-exhaust high temperature cyclone separated device. high collection of bed
material. high heat transfer coefficient, high ability of overload.

Structure Diagram

WWW.V-FLO.COM

WWW.V-FLO.COM

Limestone can be added in bed material. during burning process reacts with SO2 of flue

V-FLO
2

TEL:+8610 88580010/51906628
FAX:+8610 88580150

V-FLO

5th Floor East, Jiahuiyuan, Huaao Center,


No.31 Zizhuyuan Road, Haidian District, Beijing, China

Technical Parameter

Model (Capacity/Pressure)

35/3.82

75/5.29

75/3.82

75/5.29

130/3.82

130/5.29

35

35

75

75

130

130

Steam Pressure (Mpa)

3.82

5.29

3.82

5.29

3.82

5.29

Steam Temperature ()

450

485

450

485

450

485

Feed Water Temperature ()

150

150

150

150

150

150

8594.98

8530.18

18417.81

18321.07

31924.21

31756.52

Coal consumption (Kg/h)

Soft Coal, Blind Coal, Lean Coal, Wood Coal, Coal Gangue, Coal Slurry,
Refinery Coke

Fuel

Temperature of Drain Smoke ()

150

150

150

150

150

150

Design Thermal Efficiency (%)

87

87

87

87

87

87

Primary Air Preheat Temperature ()

150

150

150

150

180

180

Secondary Air
()

150

150

150

150

170

170

1:1

1:1

1:1

1:1

1:1

1:1

2.02.3

2.02.3

2.02.3

2.02.3

2.02.3

2.02.3

Desulfurization efficiency (%)

90

90

90

90

90

90

Limestone Granularity (mm)

10

10

10

10

10

10

Fuel Granularity (mm)

Width (mm)

9200

9200

11420

11420

14420

14420

Depth (mm)

13555

13555

15590

15590

20700

20700

Max Height (mm)

26750

26750

32732

32732

38730

38730

Preheat Temperature

Air-material Ratio

Ca/S

V-FLO
3

WWW.V-FLO.COM

WWW.V-FLO.COM

Capacity (t/h)

TEL:+8610 88580010/51906628
FAX:+8610 88580150

V-FLO

5th Floor East, Jiahuiyuan, Huaao Center,


No.31 Zizhuyuan Road, Haidian District, Beijing, China

Technical Parameter (Continue)

130/9.8

220/3.82

220/5.29

220/9.8

440/13.7

670/13.7

Capacity (t/h)

130

220

220

220

440

670

Steam Pressure (Mpa)

9.8

3.82

5.29

9.8

13.7

13.7

Steam Temperature ()

540

450

485

540

540

540

Feed Water Temperature ()

215

150

150

215

250

215

30288.44

54025.58

53741.81

51256.36

102520

51256.36

Coal consumption (Kg/h)


Fuel

Soft Coal, Blind Coal, Lean Coal, Wood Coal, Coal Gangue, Coal Slurry,
Refinery Coke

Temperature of Drain Smoke ()

150

150

150

150

150

150

Design Thermal Efficiency (%)

87

87

87

87

87

87

Primary Air Preheat Temperature ()

200

200

200

200

200

200

Secondary Air Preheat Temperature


()

200

200

200

200

200

200

Air-material Ratio

1:1

1:1

1:1

1:1

1:1

1:1

2.02.3

2.02.3

2.02.3

2.02.3

2.02.3

2.02.3

Desulfurization efficiency (%)

90

90

90

90

90

90

Limestone Granularity (mm)

10

10

10

10

10

10

Fuel Granularity (mm)

Width (mm)

14010

16700

16700

16700

29000

34000

Depth (mm)

20800

23200

23200

23200

32000

36700

Max Height (mm)

40300

43200

43200

43200

55500

63500

Ca/S

V-FLO
4

WWW.V-FLO.COM

WWW.V-FLO.COM

Model (Capacity/Pressure)

Вам также может понравиться