Вы находитесь на странице: 1из 2

LCD MENU

SELF TEST PRINTING

EXIT CONTROLLER MPL (B) MPP (B) CX Model (C) 4224 4234 3287 3262 3268 4214 CSET (B) (22 selections) Compat Op (C) CR MPP+1 NL MPP+1 FF To Col FF To Lin Null Supp FF If Pos Auto EOB Prnt Comp STO Alarm Space Case EAB IR Timout ScreenBuf TX Model (T) 4234 4245 5224 5225 5256 5262 5219 3812 4214 Compat Op (T) STO Alarm Tx Addres (T) 0 thru 6 SCS Locks (B) Clear All PPM SD PPM DO PPM DD PPM QQ PPM DX STO/SPPS SHF SVF SCD SLD FF TST Mode (B) None Conf Rpt Buf Dump

EMULATION ANSI 3.64 IBMGP PPXL III FX286e SPC MODE None Quiet Multipart INTFACE Serial CentrPar SAVE Format 1, 2, 3, 4 MSG LANG English French German Italian Spanish CHAR SET Set 1 Set 2 LPI 3, 4, 6, 8 CPI 10 thru 20 FONT Gothic DP Gothic LQ Courier DP Courier LQ HEAD GAP Ribbn Chg Semi-Auto 1 (Stall) thru 55 Automatic 1 (Stall) thru 20 UTILITY Prnt Stat PR Format Hex Dmp None Standard Enhanced Test Prn 8 Max 13.6 Max Shear Adj FORM LENG MARGINS Right Left Top Bottom PRNREF Left Top PRMENU
(C) = Coax Interface Mode Only (T) = Twinax Interface Mode Only (B) = Both Interfaces

1. 2. 3. 4. 5. 6. 7. 8.

Press <ON LINE> key. Press <PROG> key. Press <> key until ... Press <PROG> key. Press <> key until ... Press <PROG> key. Press <PROG> key. Press <PROG> to end test.

On Line LED goes out. LCD = "Prog :Exit" LCD = "Prog :Utility" LCD = "Utilit:Prnt Stat" LCD = "Utilit:Test Prn" LCD = "Test P:8" Max" Test print begins.

STATUS PRINT
1. 2. 3. 4. 5. Press <ON LINE> key. Press <PROG> key. Press <> key until ... Press <PROG> key. Press <PROG> key. On Line LED goes out. LCD = "Prog :Exit" LCD = "Prog :Utility" LCD = "Utilit:Prnt Stat" Status print begins.

FORMAT PRINT
1. 2. 3. 4. 5. 6. Press <ON LINE> key. Press <PROG> key. Press <> key until ... Press <PROG> key. Press <> key until ... Press <PROG> key. On Line LED goes out. LCD = "Prog :Exit" LCD = "Prog :Utility" LCD = "Utilit:Prnt Stat" LCD = "Utilit:PR Format" Format print begins.

To use the parallel interface in the 3910IS / 3940IP printers, the twinax or coax adapter provided with the printer must be connected. If neither adapter is connected, the Program Mode cannot be accessed to select CentPar in the Interface submenu. 65 No Interface will display on the LCD.

INITIALIZATION
1. 2. 3. Press <PARK/PATH> and <FONT> keys as you apply power to the printer. Hold both keys until the printer beeps. This may take up to 10 seconds. A flashing FAULT LED is also a sign of a successful initialization. Press the <CLEAR> key. 1. 2.

RIBBON INFO (Manual Head Gap)


(3910IS) To properly install a ribbon, it is recommended that the paper be in a parked position by pressing the <PARK/PATH> key. Never install a ribbon when paper has just been loaded and is sitting at top of form. This can cause damage to the metal smudge shield on the ribbon guide. Open the top cover and set the lever on the right inside frame to the "RIBBON CHANGE" position. Install and align the cartridge in the printer. Snap the cartridge firmly into place on the left and right sides. Snap the ribbon guide onto the print head nozzle. Rotate the ribbon advance knob to remove any slack from the ribbon fabric. Move the print head all the way from left to right to verify it does not make contact with the ribbon cartridge. Close the top cover.

PRINT GAP ADJUST (Auto Head Gap)


(3940IP) 1. 2. 3. 4. 5. 6. 7. 8. Press <ON LINE> key. Press <PROG> key. Press <> key until ... Press <PROG> key. Press <> key until ... Press <PROG> key. Press <> or <> key. Press <PROG> key. On Line LED goes out. LCD = "Prog :Exit" LCD = "Prog :Head Gap" LCD = "Head G:Ribbn Chg" LCD = "Head G:Automatic" LCD = "Automa>n" n = value of adjustment Lower n = closer PH distance Higher n = farther PH distance Saves value to current format

3. 4. 5. 6. 7. 8. 9.

OPTIONS & ACCESSORIES


Manual / Programmers Manual / Service Manual / Users (3910IS) Manual / Users (3940IP) Output Paper Rack Paper Basket Pedestal (Universal) Pedestal Catch Tray (Univ Ped) Ribbon (standard) Ribbon (infrared) Print Head Tractor Assembly GEK-88793E GEK-88996A GEK-88957C GEK-88984 3A0113B01 3A0120B01 3A1213B01 3A1213B05 3A0100B02 3A0100B03 3D1302G03S 3A0108B05

NOTE1: The <PRINT QUALITY> key will start and stop a print test, and the <TEAR OFF> key will advance the paper. NOTE2: Every time the printer automatically adjusts the print gap, two small columns of dots are printed at the top of the form about two inches from the left margin.

PRINT GAP ADJUST (Manual Head Gap)


(3910IS) 1. 2. 3. 4. Move the "RIBBON CHANGE" lever slowly towards the rear of the printer as it is printing. Position the lever for the best quality print. If the print is light or characters not fully formed, continue to move the lever towards the rear of the printer. If the print starts to smudge, move the lever towards the front of the machine. CAUTION: Smudged print could cause the paper to tear or do damage to the print head.

HOW TO CONTACT GENICOM


U.S.A.
GENICOM USA .....................................800-436-4266 BBS........................................................540-949-1576 Technical Support ..................................540-949-1031 GENICOM Web Site ..............................http://www.genicom.com Printer Sales .................................................. telemarketing@genicom.com Technical Support ......................................... techsupport@genicom.com Service Training ............................................ essctrain@essc.com

RIBBON INFO (Auto Head Gap)


(3940IP) 1. 2. 3. A ribbon may be installed only when the print head is fully backed away from the striker bar. To properly install a ribbon, paper must be in a parked position by pressing the <PARK/PATH> key or ... Menu must be set to the "Ribbon Change" utility function.

RIBBON CHANGE VIA MENU


1. 2. 3. 4. 5. Press <ON LINE> key. Press <PROG> key. Press <> key until ... Press <PROG> key. Press <PROG> key. On Line LED goes out. LCD = "Prog :Exit" LCD = "Prog :Head Gap" LCD = "Head G:Ribbn Chg" LCD = "Head G:Ribbn Chg" LCD blinks three times. Print head backs away. Open top cover and remove old ribbon. Install new ribbon (See steps 5 thru 9 in the RIBBON INFO (Manual Head Gap) section). Press <PROG> key. Print head adjusts to proper position.

INTERNATIONAL
Product Sales.........................................info@genicom-intl.com Australia .................................................61-2-9417-6411 Belguim ..................................................32-2-712-6270 Canada ..................................................800-268-0464 Denmark ................................................45-45-421120 France....................................................33-1-69-542-317 Germany ................................................49-6196-65990 Hong Kong .............................................852-2805-3601 Italy ........................................................39-2-253041 Singapore...............................................65-28-64240 Spain......................................................34-1-351-48-99 Sweden ..................................................46-31-876-500 United Kingdom......................................44-1252-744400

Pocket User Guide

Serial Matrix Printers


GENICOM

6. 7. 8.

(06/98) (Rev 007)

GEK-89353