Universal Time Delay Relay

Type NT 10

ABB a global leader

ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. The ABB Group of companies operates in around 100 countries. ABB has been present in India since 1928. Today it has 14 manufacturing facilities in the country. Customers are served through an extensive countrywide presence of around 30 marketing offices, 8 service centres, 3 logistic warehouses and a network of over 775 channel partners. ABBs Power Technologies business offers electric, gas and water utilities as well as industrial and commercial customers a wide range of products, systems and services for power generation, transmission and distribution. ABBs turnkey solution capabilities in the sector range from bulk power transmission, turnkey substations and complete electrification to substation automation and network management systems.

The product offering covers a wide spectrum of technologies across the entire voltage range including indoor and outdoor circuit breakers, air and gas insulated switchgear, instrument transformers, disconnectors, capacitor banks and filters for reactive power compensation, power and distribution transformers and a range of power distribution products like Compact Secondary Substations (CSS) and Ring Main Units (RMU).

Advantage ABB
120 years of technology and innovation Unparalleled domain competence Vast global experience Total solution provider Large installed base Environment-friendly technologies

ABB

Universal Time Delay Relay type NT 10


Features
* Both signaling duty and trip duty contacts available * Micro-controller based design for high accuracy The multiple user selectable options provide flexibility to user, for use in various applications. The wide timing range, high timing accuracy and consistency of operation can replace any other time relays. The four LEDs on the front panel indicates status of relay. The presence of healthy auxiliary supply is indicated by green 'Uaux' LED. The operation of relay is indicated by red 'TRIP' LED. The yellow 'Start' LED indicates, 'timing' status in 'ON Delay' and 'OFF Delay' modes. In 'Flasher' and 'Interval' mode Start LED indicates the status of control input. The start LED additionally indicates the change of mode selection. When mode setting is changed, yellow 'Start' LED blinks and the relay does not respond to the control input till mode setting change is applied by pressing 'Reset' push button. The 'IRF' LED indicates the internal relay fault.

* 4-User configurable operating modes * Wide timing range * Easy Setting through DIP switches * Manual Reset 'Flag' LED indication The NT 10 relay is intended for use where high operating requirements are necessary, such as in protection relay systems, control equipment, industrial processes, and control and signal systems. The time delay relay type NT 10 is high precision, numerical time relay with builtin electro mechanical output relays providing- two CO signaling duty contacts and one NO trip duty contact. The micro-controller based relay design provides accurate timing and varied operating modes. The four operating modes are: ON Delay, OFF Delay, Flasher and Interval. The required timing and operating mode can be set by adjusting the DIP switches on the front panel. The timing function is triggered by control input depending on the mode selection. The control input has same rated voltage as auxiliary voltage and is galvanically isolated.

Application:

Description:

Block Diagram:

ABB

Universal Time Delay Relay type NT 10


Operational Modes:

The following modes are possible when the relay is energized with auxiliary supply. ON Delay: In this mode, the timing starts when the control input is applied and after the set time has elapsed, the delayed output switches to the operate condition
Uaux Control I/P Start LED O/P Contact TRI P LED Reset
t t

OFF Delay: In this mode, the output immediately switches to operate condition when applying the control input and in which the timing starts when the control input is disconnected and the output switches to released condition after set time has elapsed
Uaux Control I/P Start LED O/P Contact TRI P LED Reset
t t

Interval: In this mode, the relay switches the output to operate condition for set time when the control input is applied or removed
Uaux Control I/P Start LED O/P Contact Trip LED Reset
t t

Reset PB will not have any effect in this mode

Flasher: In this mode, the output periodically switches on and off with substantially identical pulse on time and pulse off time as long as the control input is applied
Uaux Control I/P Start LED O/P C ontact Trip LED Rese t t t

Reset PB will not have any effect in this mode ABB

Universal Time Delay Relay type NT 10


Technical Data

General Energizing quantities, rated values and limits: Rated Auxiliary Voltage Un (X1- 2,4) : 18 - 80V dc 80 - 265V ac/dc Control Input (X2- 1,2) : 24 - 250 V ac/dc Rated Frequency: 50Hz Power Consumption, Uaux Before Operation : < 3W After Operation : < 4W Power Consumption, Control Input < 0.6W Rated ambient temperature: -100 C to 550 C Weight 1.1 Kg Terminals Suitable for 2.5 sq.mm wire Performance Specification: Time delay Range: Time Adjustment: Accuracy Setting Accuracy: Repeat: Change in operate time at voltage change within rated range: Change in operate time at temperature change within rated range:

0.01- 1.65 sec, 0.1- 16.5sec, 1- 165 sec, 10- 1650 sec * 00 - 165 * 10ms/ 100ms/ 1s/ 10s +/- 5ms or <1% of set value, whichever is greater @reference conditions +/- 5ms or <1% of set value, whichever is greater @reference conditions +/- 3ms

+/- 3ms * - In OFF delay mode minimum operate time is 30ms.

Contact Data: Tripping contact Terminals: Rated voltage : Rated current : Make and carry for 0.5 s : Make and carry for 3.0 s : Breaking capacity for dc circuit with L/R < 40 ms,at 48/110/220 V dc : Contact material: Signaling contacts Terminals: Rated Voltage : Rated current : Make and carry for 0.5 s : Make and carry for 3.0 s : 1Breaking capacity for dc circuit with L/R < 40 ms,at 48/110/220 V dc : Contact material: Electrical endurance, IEC 255-23:

X2- 9,10 250 V dc / ac 5A 30A 10A 5A/ 3A/ 1A AgNi X2, 3- 4- 5; X2, 6- 7- 8 250 V dc / ac 5A 10A 8A A/ 0.25A/ 0.15A AgNi 10,000 operations, at 110V dc, 0.35A resistive, 360 op/hr
5

ABB

Universal Time Delay Relay type NT 10


Technical Data

Electrical tests: Insulation, IEC 60255-5 Dielectric test Impulse test Insulation resistance test Power supply tests, IEC 60255-11 Interruption of dc voltage Interruption of ac voltage Ripple in dc voltage

2KV, 50Hz, 1min 5KV, 1.2/50us, 0.5J >100M Ohm at 500V dc 40ms/ 80v, 10ms/ 18v 70 ms/ 80v max. 12% of dc value

Electromagnetic compatibility tests: 1 MHz burst disturbance test, IEC 60255-22-1 Class III Common mode: 2.5KV, 1MHz, 400 pulses/sec Differential mode: 1.0KV, 1MHz, 400 pulses/sec Electrostatic discharge test, IEC 60255-22-2 Class III Contact discharge: 6KV, 150 pF/ 330 ohm Air discharge: 8KV, 150 pF/ 330 ohm Radiated electromagnetic field immunity test, IEC60255-22-3 10V/m, f = 80...1000MHz Fast transient disturbance test, IEC 60255-22-4 Level III Power supply ports: 2KV, 5/50 ns, 50 Ohm, class B I/O ports: 2KV, 5/50 ns, 50 Ohm, class B Surge immunity test, IEC 60255-22-5 Class III Common mode: 2 kV, 1.2/50 us, Rs = 12 ohm Differential mode: 1 kV, 1.2/50 us, Rs = 2 ohm Immunity to conducted disturbances induced by radio frequency fields, 10V, f=150KHz...80MHz IEC 60255-22-6 Conducted and radiated radio-frequency emission tests, IEC 60255-25, EN55011CISPRII Conducted emission (mains) Class A Radiated emission Class A Power frequency magnetic field immunity test, IEC 61000-4-8 Continuous 100 A/m Short Duration 300 A/m Mechanical tests: Vibration response and endurance test, IEC 60255-21-1 Shock response and endurance test, IEC 60255-21-2 Bump test, IEC 60255-21-2 Seismic Test, 60255-21-3

Class I, 10150Hz Class I, 11ms Class I, 10g, 1000 bumps/dir Class I

ABB

Universal Time Delay Relay type NT 10


Technical Data

Environmental tests: Degree of protection by enclosure when panel mounted (front side), IEC 60529 Dry heat test, IEC 60068-2-2 Dry cold test, IEC 60068-2-1 Transport & Storage temp range, IEC 60068-2-48 Damp heat test, cyclic (12 + 12hr cycle) test, IEC 60068-2-30 Condition

IP 54 + 550 C/ +700 C - 100 C/ -250 C -400 C/ +700 C

96% RH, 6 days

Dimensions

Ordering Details:
Relay Type: Contact : Rated Voltage: NT 10 1NO + 2 CO 18 - 80 Vdc 80 - 265 Vac/dc Article No. 1MYN596701-A 1MYN569701-B

ABB

ABB Limited Maneja, Vadodara 390013, India Tel: +91-265-2604386 Fax: +91-265-2638922

Regional Marketing Offices: North No.14, Mathura Road P.O. Amar Nagar Faridabad 121 003 Tel: +91 129 2275592, 2279627, 5049000 Fax: +91 129 2279692/5019 SCO No.13-14-15 (3rd Floor) Sector 34-A Chandigarh 160 022 Tel: +91 172 2606093 Fax: +91 172 2601618 South 5th Floor, West Wing Khanija Bhavan 49, Race Course Road Bangalore 560 001 Tel: +91 80 22949779 Fax: +91 80 22949808 Century Plaza No. 3C, 3D & 3F, 3rd Floor 561 / 562, Anna Salai Teynampet (Mount Road) Chennai 600 018 Tel: +91 44 24340201 Fax: +91 44 24340282 Central 4th & 5th Floor Maruti Heights Aamanaka, G E Road Raipur 492 099 Tel: +91 771 4701016 FF-9A, 1st Floor Manasarover Commercial Complex Hoshangabad Road Bhopal 462016 Tel: +91 755 4223572 Fax: +91 755 4253323 West ABB House Dr. S B Path Ballard Estate Mumbai 400 038 Tel: +91 22 56318231 39 Fax: +91 22 56318276/77 East 4th Floor No. 9, Elgin Road Kolkata 700 020 Tel: +91 33 22832906/8 Fax: +91 33 22832990

www.abb.co.in

1MDB08221-YN 07/08