Вы находитесь на странице: 1из 44

Industrial Centrifugal Fans: Centripal EU

Centripal EU Fans

The Centripal EU range has been designed by Flkt Solyvent Ventec to become the new European Reference of Centrifugal fans in the Flkt Woods Group. The latest innovations are reflecting the 90 years of experience of Flkt Solyvent Ventec, strongly recognised on the market for its high performance characteristics, reaching up to 88% efficiency with airfoil blades. The development of the range has enabled a high level of standardisation integrating all ancillaries and fittings, enabling fans to be delivered in short lead times, with a maximum of flexibility.

Summary
General presentation
Fan and applications ................................................................................................................................................................................................................... 4 Key features of a centrifugal fan .................................................................................................................................................................................. 6 The different impeller types ............................................................................................................................................................................................... 8 ATEX norm and related fan types ......................................................................................................................................................................... 10

Small sizes concept:


The range ........................................................................................................................................................................................................................................... 14 Fans for clean air applications Medium pressures .................................................................................................................................................................................................................. 16 High pressures ............................................................................................................................................................................................................................ 18 Fans for dust-laden air applications Medium pressures .................................................................................................................................................................................................................. 20 High pressures ............................................................................................................................................................................................................................ 24 Fans for heavily dust-laden air applications Medium and high pressures ........................................................................................................................................................................................ 26

Large sizes concept:


The range ........................................................................................................................................................................................................................................... 32 Fans for clean air applications .............................................................................................................................................................. 34 Fans for dust-laden air applications ............................................................................................................................................ 36

System design recommendations ..................................................................................................................................................... 38 Ancillaries .................................................................................................................................................................................................................................... 40 Solyvent in the Flkt Woods Group .............................................................................................................................................. 42

Centripal EU: a modular concept built around A design made and adapted
DE-DUSTING Pressurised or depressurised kilns, fans working as blowers or in exhaust mode.

GENERAL VENTILATION - FUME EXTRACT Extractors in workshops, fresh air make up and supply, fans for filtering systems, clean rooms

PROCESS FANS IN PAINT BOOTHS Fans with removable impeller design, re-circulating fans for furnaces, exhausters in spray booths

FANS FOR GLASS INDUSTRY Fans for ovens, glass mould cooling, furnace wall cooling, glass annealing, blowers in the cooling process.

CHEMICALS - GAS EXPLOSION PROOF DESIGN FOR HAZARDOUS AREAS

Blowers, exhausters, certified fan design, category 2 & 3, suitable for Zones 1 & 2 of the directive.

AGRICULTURE - DUST EXPLOSION PROOF DESIGN FOR SILO APPLICATIONS Certified fan design, category 2 & 3 for dusty environment Zone 21 & 22 of the directive.

FURNACE BURNER AIR SUPPLY Introduction of fresh air through a high pressure blower.

highest aerodynamic performance for nearly all industrial applications


TEXTILE MACHINERIES Blowers, exhausters and re-circulating fans for the complete production process.

WOOD AND PAPER INDUSTRIES Blowers/exhausters for kilns in de-dusting, dryers for paper or wood production processes.

FOOD INDUSTRY Coolers, dryers, water evaporation (pasta, milk)

MARINE - OFFSHORE Exhausters, blowers, motor cooling, engine room air circulation...

FANS FOR ORIGINAL EQUIPMENT MANUFACTURERS (OEMS) Machines for packing, plastic films, DC motor cooling, generator cooling, sweepers,

IMPELLERS AND INLET CONES OEMs for filtering systems, air treatment, re-circulation systems, car wash, industrial vacuum

TRACTION Fans for trains, buses: cooling blowers for traction motors, braking resistors, converters, transformers

5 typical features determining a centrifugal fan:


1 Arrangement types
ISO 13349: 1999 Description

Single width impeller. Belt Driven Arrangement. Overhung impeller fitted onto an intermediate shaft, supported by 2 bearings mounted on a Support.

Single width impeller. Direct Driven Arrangement. Overhung impeller directly fitted on motor shaft. No bearings on the fan. Motor is fixed on a Support.

Single width impeller. Direct Driven Arrangement. Overhung impeller directly fitted on motor shaft. No bearings on the fan. Flanged motor fixed on a fan casing.

Double width impeller. Belt driven arrangement Impeller mounted between bearings. Available on demand

Single width impeller. Semi-flexible Coupling Arrangement. As arrangement 1 + one motor support in the same axis.

2 Orientations
Fourteen standard orientations are available as per the diagrams. The orientations are viewed from the drive side (side opposite to the fan inlet) and are given according to the Eurovent standard.

RD 0

RD 45

RD 90

RD 135

RD 180

RD 270

RD 315

LG 0

LG 45

LG 90

LG 135

LG 180

LG 270

LG 315

3 The sizes
15 standard impeller diameters from 315 up to 1600 mm according to the R20 series.

4 Aerodynamics
6 blade types, depending on air transported (see page 8 - 9): D, B, P, L, S, T. 11 performance envelopes, corresponding to impeller width (L, M, K, H, N, P, R, S, T, V, W). (Small sizes). 8 performance envelopes, corresponding to impeller width (9, 7, 6, 4, 3, 2, 1, 0). (Large sizes).

Small sizes : Large sizes :

L ........................................................................................... P .......................................................................................... W 9 .......................................................................................... 3 ........................................................................................... 0

5 Material type and coatings


Carbon steel or Stainless steel (304L, 316L, 316Ti...) Standard coating, epoxy, galvanized steel, zinc spray...

Centripal EU
Fan series

4
Drive Arrangement 4-5: direct 1: belt 8: coupling

L
Impeller width LW 90

D
Type of blades (D - B P-L S - T)

560
Impeller diameter (mm)

RD
Rotation RD = (Right) LG = (Left)

45
Discharge direction

Adx
Material Adx: F24.2 steel, AISI 304 L: stainless steel...

Std
Coatings: - Std : standard RAL 7035 (powder) - Epoxy 120 m anti-corrosion - Galva HDG after manufacture - Finit RAL customer imposed colour

From the 1st January 2001, ISO 12499 "Industrial fans - Mechanical fan safety - Protection", the installer and end user are directed as folows: "If the fans rotating parts become accessible during service, the power supply must be completely isolated. In those circumstances, a power supply isolation unit must be placed next to the fan to enable as positive isolation of the unit during maintenance.

To conform to this international standard, all fans must be installed with a local isolating switch.

A large choice of electrical equipment, whatever your starting (method), to make you life easier: - Pre-wired electrical control panels (Star, Star Delta, double speed ...). - Pre-wired frequency inverters for fan performance control. - Safety switch (standard or explosion proof).

Basic Fan selection information ?


High fan efficiencies, low sound power levels, high performance, small surface area and long life are obtained from the fans design and selection according to the given criteria.

Fan selection is derived from:


the nature of the air to be moved and fan environmental conditions. design requirements (volume, pressure...). drive arrangement and discharge direction, available space, accessories and options...

6 different types of impellers for all applications: D, B, P, L, S, T.

Clean air

Dust-laden

D-blade
(airfoil). Suitable for handling clean air with relative humidity levels not exceeding 80 %. High efficiencies of up to 88 % and particularly low sound power levels. Suitable for L, M, (and 9 - 7 - 6 - 4 for sizes > 1000).

B-blade
(backward curved). Suitable for handling clean air with relative humidity levels not exceeding 80 %. High efficiencies of up to 85 % and particularly low sound power levels. Suitable for H, N, P, R, S, T, V, W widths, and 9- 7 - 6 - 4 - 3 - 2 - 1 - 0 for sizes > 1000.

P-blade
(flat, backward inclined). Suitable for handling humid or fairly dusty air. Efficiencies of up to 87 % with low sound power levels.

Standards
The recently developed, EU range of centrifugal fans is based on the latest European and international standards.

Aerodynamic and acoustic performance research and tests


Performed according to ISO 5801 and ISO 13347. The above research and tests have contributed to the very high efficiencies and exceptionally low sound power levels regardless of operating conditions:

Tolerances of ISO 13348 - AN 3 level Guaranted air volume and pressure : 5 % Guaranted total sound power levels : + 0 dB / + 4 dB

Mechanical and vibration tests


Our Computerized finite Element Analysis has allowed to eliminate all the natural frequencies within the working speed ranges. Guaranteed vibration levels (following ISO 14694 BV3) :

4,5 mm/s: rigid assembly. 6,3 mm/s: on AV mounts.

air

Heavily dust-laden air Air trs poussireux

L-blade
(flat, slightly backward inclined). Suitable for handling air laden with abrasive or slightly clogging dust. Efficiencies of up to 77 % with relatively low sound power levels.

S-blade
(shrouded paddle blade). Recommended for handling air laden with powdery, abrasive and clogging dust. Efficiencies of up to 70 %.

T-blade
(unshrouded paddle blade). Recommended for fibre-laden air. This blade type resist damage due to fan surge at low air volume.

Centripal Ex: a complete

certified range

Some useful information about directive 94/9/EC:


Applicable since July 1st 2003. All new installations have to conform to this new regulation. All existing installations have to be analysed and risk assessed using this new code by the end of June 2006. This European directive is applicable on all electrical equipments, and rotating machineries which are installed in an hazardous area. It is responsibility of the end user and his installer to define precisely the zone in which the fan is going to run. Zone can be different inside and outside the fan. Category of machinery has to correspond to the more dangerous zone.

3DL range certified by a notified body Certificat number: LCIE 06 ATEX 6101X

Conform to the EN 14986 standard

Correspondence between fan categories and Fan category 1G category 2G category 3G category 1D category 2D category 3D category
G = GAS , D = DUST.

zones:

Corresponding zone Zone 0 Zone 1 Zone 2 Zone 20 Zone 21 Zone 22

For categories 2G, 2D, 3G and 3D corresponding to zones 1, 2, 21 and 22, our technical file number

is:

ST M 07 TEC 2885

Additional elements of manufacturers file, following the directive:


Additional name plate: And include: . Certificates of conformity Balancing certificate. Tightness certificate for a ducted/ducted configuration. Vibration test report. Over-speed test report. Storage instructions. Starting and maintenance manuel.

10

Centripal Ex: special features of an


Fully welded construction above 11 kW.

Fan

Some other construction details imposed by the directive for steel impellers for example are:
Carbon shaft: carbon has the ability to be worn is on first start up without burning, as the seal is perfectly adjusted to the motor shaft. This means that there is no risk of ignition during start up. Anti-spark linings in brass protecting all rotating parts: cooling disk, pulleys, shafts, hubs Brass or copper inlet cones for a maximum safety, combined with a minimum distance between rotating and static parts. All bolted parts are also linked to each other via a stainless steel earthing system. certified: motors, temperature detectors, All electrical equipment has to be vibration monitoring (compulsory for 2D zones)... Pulleys to be balanced, belts to be made in an anti-static material.

motor choice
Dust environments:
Motors are certified zone 21 or 22. Depending if dust is conductive or not, protection mode is going to be IP 6X or 5X (generally IP 65 or IP 55).

Gas environment:
If danger is unlikely to happen, likely to happen or permanent, motor can be of a spark-proof design, explosion proof design, or prohibited.

Motor choice in a dust environment:


Azardous area Danger zone Protection level of equipment Motor category Protection mode

Motor choice in a gas environment:


Azardous area Danger zone Protection level of equipment Motor category Protection mode

Continous danger Likely to happen Unlikely to happen Unlikely to happen

20 21 22 Conductive dust 22 Non conductive dust

Very high High Normal

1D 2D 3D

Prohibited IP 6X IP 6X

Permanent danger Likely to happen Unlikely to happen

Very high

1G

CEI EN 50284 EEx-d EEx-de EEx-e EEx-nA

High

2G

Normal

3D

IP 5X

Normal

3G

For the gas environments, additional data to be considered is surface temperature of the motor itself, depending on a gas transported or ambiant:
Group I IIA T1 450 C Methan (mines) Aceton, Acetic Acid, Ammoniac, Methan,Methanol, Propane,Toluene Koke gas, Water gas Hydrogen T2 300 C Butane, Ethyl alcohol Ethylene Acetylene T3 200 C Cyclohexane, Kerosen, THF Hydrogen Sulphide T4 135 C Acetaldehyde T5 100 C T6 85 C -

IIB IIC

Ethyl ether -

Nitrate ethyl

11

12

Centripal EU Small sizes


Drive Arrangements 1 - 4 - 5 Pre - selection charts

13

Centripal EU small sizes: an innovative range,


Arrangement 5: the most compact dsign
A modular concept from 250 to 710 mm

4 possibilities for installation:


Fixation on the inlet flange. Fixation on the outlet flange. Fixation with 2 feet on the floor. Fixation on AV mounts' kit.

Product features:
From 250 up to 710 mm impeller Diameter. Flow rates up to 5,5 m3/s. Pressures up to 7000 Pa. Small surface area. Frequency converter speed control possible. Gas temperatures between -20 C to + 60 C. All impeller types available.

Applications : de dusting, OEM (cooling, drying).

Arrangement 4: a complete and cost effective range

Orientable construction One casing to suit all arrangements: 14 different orientations available in 45 increments thanks to the octogonal casing design. Flexibility of the units for on-site modifications is achieved allowing the casing or motor size to be changed.

Easy for maintenance The bolted motor support enables the impeller to be easily removed from the casing for ease of cleaning and maintenance. Due to the design, stainless steel fan configurations can be made with stainless steel for all gas contact parts and mild steel for the motor support, thereby reducing the overal cost.

14

modular and compact, from 250 up to 900 mm


(extension to 1250 mm for L and M)
Overhung impeller fitted directly on motor shaft:
Small surface area Reduced power requirements Simplified maintenance: no belts, no bearings. Standard fans can be adapted for temperature ranges of 20 C up to +200 C.

The advantages are:


Wide openings in the motor pedestal enable easy access for cabling. Inlet and outlet flanges according to ISO 13351. Sufficient space on the motor pedestal allows the fitting of a safety switch. The large access door enables easy and efficient inspection of the impeller.

Arrangement 1: made for high temperatures and high rotation speeds


Overhung impeller fitted onto an intermediate shaft supported by two bearings and equipped with a V-belt type drive.
Fan capacities fully site-adjustable, High fan speeds, High temperature applications, Special shaft seal, Standard fans can be used at temperatures from -20 C to +350 C.

A very compact design.

Balt maintenance and the adjustment of tension is easily facilitated thanks to a fully adjustable support.

15

Centripal EU small sizes - Clean air applications


Medium pressures

Features
Centripal EU fans for clean air applications: D- type hollow airfoil blades. These are available in 2 impeller widths (L, M). High efficiency levels are obtained with D-type impellers: aerofoil, i.e.,aerodynamically shaped blades matching the inlet cone, reduce shocks produced at wheel entry, resulting in smooth air flow across the blade surface and eliminating eddy currents producing turbulence and noise. Low absorbed powers, high fan efficiencies and low sound power levels.

Typical applications
General ventilation. Boilers and furnaces. Heat treatment. Dehumidification. Smoke exhaust systems. Air conditioning.

16

Fan pre-selection chart - Direct drive


The pre-selection chart below should be used to determine which drive arrangement best meets design requirements: 50Hz direct drive fans at 2,900 or 1,450 rpm, 950 rpm.

CENTRIPAL EU 4 - MD/LD - 2, 4 and 6 poles.

Arr. 4

total pressure (Pa)

7000
MD 630 2p

6000
MD 560 2p
LD 5

5000 4500 4000 3500 3000 2500 2000


M D 400 2p

MD 50 0

60 2

2p

LD 5

00 2

MD 450

2p

LD 4

50 2p

LD 40 0
355

2p
04 90 MD

MD 355 2p

LD
LD 315 2p

2p
8 MD

1500

MD 315 2p

4p 00

7 MD 4p 10

p 06 125 LD

LD 9

MD

1000
MD 56 MD

63 04 p
LD 7

00 4

LD 800

750

04

4p

50 04 p

10 4

p
4p 630 LD

500 400

4 550 LD

4 500 LD

4 LD 4p 50

200 100 0,2 0,3 0,4 0,5 1 2

9 10

15

20

30

40

50

Volume (m3/s)

Fan pre-selection chart - Belt drive


CENTRIPAL Eu 1 - MD/LD
total pressure (Pa)
8000 7000 6000
Arr. 1

5000 4500 4000 3500 3000 2500 2000

315

355

400

500

560

630

710

1250

MD

315 1500

355

400

450

500

560

630

710

800

900

1000 1250

LD

1000 750 500 400 300 200 100


CENT_EU1-MD-LD

0,1

0,2

0,3

0,5

10

15

20

24

30

40

Volume (m3/s)

17

Centripal EU small sizes - Clean air applications


High pressures

Features
Centripal EU high pressure - clean air fans feature B-type curved blades and are available in 8 impeller widths (H, N, P, R, S, T, V and W). Combinations of design features ensures fans precisely match design requirements. Centripal EU equipped with B-type impellers are best suited for low and very low air volume requirements.

Typical applications
Furnace burner air supply. Fluidization. Pneumatic conveying. Glass annealing. Diesel engine booster. Air curtains. Glass mould cooling, heating boiler optical cell cooling, etc. Pulsators in waste water treatment plants.

18

Fan pre-selection chart - Direct drive, 2 and 4-pole motors


The pre-selection chart below should be used to determine which drive arrangement best meets design requirements: 50Hz direct drive fans at 2,900 rpm
Arr. 4

CENTRIPAL EU 4 - H, N, P, R, S, T, V, W.
total pressure (Pa) total pressure (Pa)
18000 17000 16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 355 315 1000 355
CENT_EU4_2P-1

TB 1000 RB 900 900

18000 17000 16000 15000 14000 13000 12000 11000 10000 800 800 710 710 7000 6000 630 630 VB 1000 1000

WB

SB 900 900 900 PB 900 800 800

800 800 800 710 710 710 630 560 500 450 400 400 450 450 500 500 560 560 630 630 NB

9000 8000

710 710 630 630 560 560 500 500 450 400 355 630

710

HB

5000 560 4000

560 500 450

560

500 500 3000


450

450 400 355

450 400 315

2000

355

1000

315
CENT_EU4_2P-2

0,05 0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

3 6

0,05 0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

10

Volume (m3/s)

Volume (m3/s)

Fan pre-selection chart - Belt drive


CENTRIPAL EU 1 - H, N, P, R, S.
total pressure (Pa)
Arr. 1

20000 18000 16000 15000 14000 13000 12000 11000 10000 9000 400 8000 7000 6000 5000 4000 3000 2000 355 355 400 450 560 500 450 500 560 630 RB 630 800 800 NB

total pressure (Pa)

20000 18000 16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 355 355 560 500 450 400 400 450 400 355 500 630 560 500 450 630 800 630 560 800 HB SB 710 800 900 PB

1000
CENT_EU1-R-N

1000 500
CENT_EU1-S-P-H

500

0,05 0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

3 6

0,05 0,1

0,2

0,3 0,4 0,5 0,6 0,8 1

1,5 2

3 6 8

12
3

18

Volume (m3/s)

Volume (m3/s)

19

Centripal EU small sizes - Dust-laden air applications


Medium pressures

Features
Centripal EU fans for dust-laden air applications. Backward inclined blades (P and L). These are available in 2 impeller widths (L, M). Centrifugal force and blade inclination combine to peel off dust, significantly reducing particle build-up on the impeller. The P type impeller with its sharply inclined blades is most suitable for slightly dust-laden, non-clogging air applications. Slightly inclined, the L-blade impeller is designed for handling slightly clogging, particle-laden abrasive air and corrosive gases.

Typical applications
Furnace burner supply air. Dust separators. Coating machine dedusting. Dusty (cement factories, steel mills) or humid (paper mills, dyeing) environment ventilation systems.

20

Fan pre-selection chart - Direct drive


The two pre-selection charts below should be used to determine witch drive arrangement best meets design requirements: 50Hz direct drive fans at 2,900 1,450 or 950 rpm.
Arr. 4

CENTRIPAL EU 4 - ML/LL.
total pressure (Pa)
8000 7000

6000

ML 56
5000 4500 4000 3500 3000
ML 45 0 2p
ML 500

0 2p

2p

LL 560 2p

LL 500 2p

ML 40
2500

0 2p

LL 450 2p

2000

ML 355 LL 400 2p 2p

ML 90 04

p 04 80 ML

1500

LL 355 2p LL 3 15 2 p ML 315 2p

LL

LL

12

L M 0 71

90 04 p

50 6P

1000

4p

ML 630

p 04 71 LL

4p LL 800

ML 5

4p

750

4 p LL 04 50 ML

60 4p

4p 630 LL

p 60 4 LL 5

500 400

LL 5 00 4

50 4p

200 100 0 0,1 0,2 0,3 0,5 1 2

10

15

20

30

40 50 Volume (m3/s)
Arr. 4

CENTRIPAL EU 4 - MP/LP.
total pressure (Pa)
7000
MP 630 2p

6000

5000 4500 4000


MP 5

MP 560 2p

3500 3000 2500


MP 450 2p

00 2p
LP 450

2p

MP 400 2p
2000
MP 35 5 2p

LP 4 00 2 p

MP

LP 3 55 2 p

900 4p

1500
MP 31 5 2p

MP 800

MP 710

4p

1000

4p

750

MP 63

LP 9

LP 800

0 0 4p

LP 71

LP 315 2p

500 400

0 4p

MP 56

LP 630

MP 50

0 4p

LP

4p

4p 500 LP 0 4p

LP 4 50 4

560 4p

0 4p

4p

200 100 0 0,1 0,2 0,3 0,5 1

10

15

20

30

40 50 Volume (m3/s)

21

Centripal EU small sizes - Dust-laden air applications

Fan pre-selection chart - Belt Drive


Arr. 1

CENTRIPAL EU 1 - ML/LL.
total pressure (Pa)

Volume (m3/s)

22

Fan pre-selection chart - Belt Drive


Arr. 1

CENTRIPAL EU 1 - MP/LP.

Volume (m3/s)

23

Centripal EU small sizes - Dust-laden air applications


High pressures

Features
Centripal EU fans for dust-laden air handling feature L-type flat blades and are available in 4 impeller widths (H, N, R and S). Centrifugal force and blade inclination combine to "peel off" dust, significantly reducing clogging hazards. The L-blade is highly suitable for slightly clogging, dust-laden air and corrosive gases.

Typical applications
Dedusting. Chemical degassing. Plant recycling (cement factories). Powder and granulated product pneumatic conveying. Waste incinerators. Sweepers.

24

Fan pre-selection chart - Direct drive


The pre-selection chart below should be used to determine which drive arrangement best meets design requirements: 50Hz direct drive fans at 2,900 rpm
Arr. 4

CENTRIPAL EU 4 - SL/RL/NL/HL.
total pressure (Pa)

16000 15000 14000 900 13000 12000 11000 10000 9000 710 8000 7000 530 6000 5000 4000 450 400 355 355 315 1000
CENT_EU4_2P-3

RL SL 900

800 800 800

NL

710 710 710 HL

530 530 530

560 500

560 560 500 560

500 450

500

3000 400 2000

450

450

400 355 315

400

355

0,05

0,1

0,2

0,3

0,4

0,5

0,6

0,8

9 Volume (m3/s)

Fan pre-selection chart - Belt Drive


Arr. 1

CENTRIPAL EU 1 - SL/RL/NL/HL.
total pressure (Pa)
16000 15000 14000 13000 12000 450 11000 10000 9000 400 8000 7000 355 6000 5000 4000 355 400 450 400 800 355 355 560 630 400 450 HL 450 560 560 SL 630 630 630 RL 800 800 NL

3000

2000

0,05

0,1

0,2

0,3

0,4

0,5

0,6

0,8

1,5

4 6 9 Volume (m3/s)

CENT_EU1-SL-RL-NL-HL

1000

25

Centripal EU small sizes - Heavily dust-laden air


Medium and high pressures

Features
Centripal EU fans for handling heavily dust-laden air can be selected with either shrouded (S-blade) and un-shrouded (T-blade) paddle blades. Fans are available in 3 impeller widths (M-H-R). This type of impeller is ideally suited for: powder and pellet-conveying applications when selected with S-blades. fibre, shavings and paper-conveying when selected with T-blades.

Typical applications
Dedusting of wood-working machines. Dust separators. Pneumatic conveying on carding and combing machines.

26

Fan pre-selection chart - Direct drive, 2 and 4-pole motors


The pre-selection chart below should be used to determine which drive arrangements best meets design requirements: 50Hz direct drive fans at 2,900 or 1,450 rpm.
Arr. 4

CENTRIPAL EU 4 - MS/MT
total pressure (Pa)
7000
MS 560 2p

6000

5000 4500 4000 3500 3000 2500

MS 5

00 2

MS 450 2p

MS 40 0

2p

MT 450 2p

MS 355 2p
2000

MT 400 2p

p 04 90 MT

MS 9

MS

1500

MS 315 2p

MT 355 2p

00 4p

p 04 80

MT 315 2p
1000

M S 71 0 4p

MT 800

M S 63 0

4p

MT

MT

4p

750

M S 56 0

63 04 p

71 04 p

4p

500 400

MT

50 0 4p

560

M T 50 0

4p

200 100 0 0,1 0,2 0,3 0,5 1

4p
3 4 5 6 7 8 10 15 20 30 40 50 Volume (m3/s)
Arr. 4

CENTRIPAL EU 4 - RT/HS/HT - 2900 rpm.


total pressure (Pa)
12000 11000

RT 800
10000 9000 8000 7000

RT 710

HT 710

RT 630
6000

HT 6

30

30 HS 6

5000

RT 560

HT 560

4000

RT 500
HT 500

HS 560

0 50 HS

3000

RT 450

HT 450

H S 45

HT 400

2000

HT 355

HS 0 40

HS 5 35

1000

500 0 0,05 0,1 0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 4 6 8

Volume (m3/s)

27

Centripal EU small sizes - Heavily dust-laden air

Fan pre-selection chart - Belt Drive


CENTRIPAL Eu 1 - HS/MS.
Arr. 1

total pressure (Pa)

12000 10000 9000 450 8000 7000 400 355 HS 630 800

6000

5000 4500 4000 3500 3000 2500 2000 315 1500 355 400 450 500 560 630 710 800 900 MS

1000

750
CENT_EU1-HS-MS

500 400 300 0 0,1 0,2 0,3 0,5 1 2 3 4 5 6 7 8 9 10 15 20

Volume (m3/s)

28

Fan pre-selection chart - Belt Drive


CENTRIPAL Eu 1 - RT/HT/MT.
Arr. 1

RT

total pressure (Pa)

12000 10000 9000 8000 400 7000 355 6000 450 500 450 630 710 800 900 800 HT

5000 4500 4000 3500 315 3000 2500 2000 800 1500 355 400 450 500 560 630 710 900 MT

1000

500 400 300 0 0,1 0,2 0,3 0,5 1 2 3 4 5 6 7 8 9 10 15 20

Volume (m3/s)

29

CENT_EU1-RT-HT-MT

750

30

Centripal EU Large sizes


Drive arrangement 1 - 4 - 8 Pre - selection charts

31

Centripal EU large sizes: a complete range in three


Arrangement 4: the cost effective solution from 1000 up to 1400 mm diameter

Fans in direct driven arrangement, from 1000 mm to 1400 mm are covering a wide range of aerodynamic working curves. Frequency converter option, enables a better comfort in use. For all applications from -20 C to +200 C.

Arrangement 1: a fully standardized range from 900 to 1400 mm diameter

Totaly adapted to high fan speeds, high temperatures applications or special shaft seal. Fan capacities fully site - adjustable standard fans can be used at temperatures from -20 C to +350 C.

32

arrangements to cover all industrial process needs


Arrangement 8: coupling driven arrangement from 900 to 1600 mm diameter
The arrangement 8 is dedicated to applications where cycles (change of speed), high temperatures (up to +350 C) and high motor power are key features for the fan. Coupling is particularly suitable for frequency drive.

Optional equipment:

Inlet guide vane: For adjustment of fan performance on site, or for air flow regulation at constant speed.

Oil bearings: This option is available on simple demand. For high rotation speeds, oil bearings are bringing more comfort in lubrication maintenance.

Rotation detectors: Mainly for arrangement 1; allows to check that the fan runs properly.

PT 100 : To check temperature elevation of bearings

Vibration monitoring: Useful in dusty environments, to monitor clogging and balancing of the impeller.

33

Centripal EU large sizes - Clean air applications

Features
Centripal EU fans for clean air applications: B or D- type hollow airfoil blades. High efficiency levels are obtained: airfoil, i.e.,aerodynamically shaped blades matching the inlet cone, reduce shocks produced at wheel entry, resulting in smooth air flow across the blade surface and eliminating eddy currents producing turbulence and noise. Low absorbed powers, high fan efficiencies and low sound power levels. B-type for highen pressure levels an narrow impellers.

Typical applications
Dedusters after filtration systems. Cooling (glass...). Industrial boilers. Smoke exhaust systems.

Fan pre - selection chart - Direct drive


CENTRIPAL Eu 4 - Widths 9 - 7 - 6 - 4, D blades (Curves at maximum speed)
total pressure (Pa)
Arr. 4

15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000
6D

4D 100 0

4D

11 20

6D 12 50

6D

112

4D

50 12

10

00

7D

11 20

7D

12 50

7D

3000 2000

100 0
9D 2 11

9D 00 10

9D

9D 12 50

00 14

1000 500
CENT_EU4_GT_01

10

15

20

25

30

35

40

45

50

55
3

60

Volume (m3/s)

34

Pre - selection chart - Belt drive


CENTRIPAL Eu 1 - Widths 9 - 7 - 6 - 4 - 3 - 2 - 1, D and B blades (Curves at maximum speed)
total pressure (Pa)

Arr. 1

25000 20000
00 10 2B 900 2B

20000 18000 16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000
1B 9 00

3B 2 11 0

0 100 3B

3B 50 12

4D 112 0
4D 100
50

2B 2 11 0

2B 12

6D 1

6D 1 120
250
1 00 0
7D

4D 1

250

6D
00 3B 9

1B 1 000

10

7D
00

0 112 1B

112 0

7D 1 250

4D 0 90

5000
2 1B 1

4000 3000

50

9D

11 20
9D 12 50
9D
CENT_EU4_GT_02

2000
9D 10 00

14

00

1000
0 5 10 15 20 25 30 35 40 45 50 55 60

Volume (m3/s)

Pre - selection chart - Coupling drive


CENTRIPAL Eu 8 - Widths 9 - 7 - 6 - 4 - 3 - 2 - 1 - 0, D and B blades (Curves at maximum speed)
total pressure (Pa)

Arr. 8

25000 20000
2B
0B 1000

2B
3D

16

20000 18000 16000 15000 14000 13000

00
3D

3D
2 11

90 0
50 12 1B

12

50

3D

16 00

900

2B 50 12

4D 1 120 3D 140 0 4D 100 0


3D 100

1B

12000 11000 10000 9000

2B

2B

6D 1250
7D 100 0

6D 1 120
4D 12

00 14

112

14

00
2B 1000

50

4D

4D

8000 7000 6000 5000 4000 3000

14 00

00 16

2000

50

9D

14

00

1000
0 5 10 15 20 25 30 35 40 45 50

55 60 Volume (m3/s)

CENT_EU4_GT_03

0 0B 1 40 0B 1250
0B 1120 0B 900

4D 900

6D 9

6 1B 900 0B 1 00

7D 125 0

600 1B 1

7D
6D

1B 1000

11 2

1B 1120

00

00 10

6D

9D 1 000

14 0

9D

11 2

9D

12

35

Centripal EU large sizes - Dust-laden air applications

Features
Centripal EU fans for dust-laden air applications. Backward inclined blades L. Centrifugal force and blade inclination combine to peel off dust, significantly reducing particle build-up on the impeller. Slightly inclined, the L-blade impeller is designed for handling slightly clogging, particle-laden abrasive air and corrosive gases.

Typical applications
Furnace burner supply air. Dust separators. Coating machine dedusting. Dusty (cement factories, steel mills) or humid (paper mills, dyeing) environment ventilation systems.

Fan pre - selection chart - Direct drive


CENTRIPAL Eu 4 - Widths 9 - 7 - 6 - 4, L blades (Curves at maximum speed)
total pressure (Pa)

Arr. 4

16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000
4L

4L 12
100 0

50

4L 11

20

6L 1 120
6L 100 0

7L
7L

7L 1 250

100

112 0

9L 1

00 0

9L 1250

9L

11 2

6L

12

50

9L

14 00

1000 500
CENT_EU4_GT_04

10

15

20

25

30

35

40

45

50

55

60

Volume (m3/s)

36

Pre - selection chart - Belt drive


CENTRIPAL Eu 1 - Widths 9 - 7 - 6 - 4 - 3 - 2 - 1, L blades (Curves at maximum speed)
27000
0 90 3L 00 10 2L 20 0 11 50 12 12 1L L1 2L 0 2 90 2L 0 90 1L
total pressure (Pa)

Arr. 1

1L
1L
0

25000 20000

00 10

3L

20000 18000 16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000

11 2

3L

125

1 3L 0 00

12 50

4 L 125 0

4L 9 00

4L 1 000
6 L 11 20 6 L 10 00

4L

112 0

7L

100 0

7 L 12 50

6L

125

7L 1 1 20
9 L 11 20

9L 1250 9L 1000

1000
5 10 15 20 25 30 35 40 45

Volume (m3/s)

Pre - selection chart - Coupling drive


CENTRIPAL Eu 8 - Widths 9 - 7 - 6 - 4 - 3 - 2 - 1, L blades (Curves at maximum speed) 27000
1 2L
total pressure (Pa)

Arr. 8

25000 20000
1L

2L
3L

20000 18000 16000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000

3L

112 0

160

3L

125

10 00

3L

140

4 L 10 00

6 L 11 20

1L

12 50
7L 10 00

6L

125 0

4L
16

12

50
4L 14 00

4L

3L

16 00

4L 9 00

00

6L 9 00

7L
9L 1250

125 0

6L
9 L 11 20

140

9L

3000 2000

10

00

9L

14 00
CENT_EU4_GT_06

1000
0 5 10 15 20 25 30 35 40 45 50 55 60

Volume (m3/s)

CENT_EU4_GT_05

9L

140

9 2L

00 0

00

00 10

1 1L 60

1 2L 25

2L

20 11 1L 0 90 1L

0
2 11 2L 0

14 00
4L

20 11

3L 900

1 1L

6L 10

40 0

00

7L 2 11 0

37

System design recommendations


Design considerations
Our fan performance curves are based on tests performed with optimum installation conditions. The inlet ducts were circular and were connected in a true alignment to the fan inlets with our standard aerodynamic inlet cones fitted. and a discharge duct equipped with an outlet extension connected to a straight measuring duct. Friction loss (system pressure) data is usually available from the duct system manufacturers catalogues. Published data is based on uniform air intake at the fan inlet. It is very rare that a real installation meets the ideal condition, it must therefore be noted that the entire system effect be taken into account to calculate the true performance requirements of the fan, i.e. All duct system components and non-uniform air intake to the fan will have an affect on the fan performance A particular ductwork component located too close to either the fan inlet or outlet will adversely affect the friction loss factors.

Inlet connections
Inlet spin
The various connections shown below all cause air spin at the fan inlet. Air spin is generally either in the direction of, or opposite to the direction of rotation of the fan impeller. If it is opposite to direction of rotation of the impeller, the power consumption will be increased.

If it is in the direction of impeller rotation, capacity will be reduced along with power consumption. Using guide vanes either upstream or in the bends can minimize loss of capacity and static pressure. The friction loss caused by such vanes will need to be added to overall system loss.

There are two solutions to this problem:


Non-uniform airflow at the fan inlet can be corrected with the use of guide vanes. We suggest that you contact our engineering department for the selection of such equipment.

Direction of impeller rotation

a) Forward spin

b) Reverse spin

5 guide vanes in elbow eliminate spin.

2 baffles placed at 90 angles

1,5 d

Cross-vane arrangement eliminates spin

0,45 d

c) Mixing box at fan inlet causing forward spin.

d) Filter at fan inlet causing forward spin.

Bee's nest

38

a = 0,15 d

Sheet steel flow straightener max. gage O,003 D

Non-uniform inlet air velocity


Duct bends at the fan inlet usually cause poor inlet distribution, with the higher air velocities at the outer radius of the bend (fig. 1).

Fig. 1

The problem can be corrected by:


installing a straight section of at least 5 duct diameters (L) between the fan inlet and the bend. installing vanes in the bend at a minimum distance of twice the inlet diameter of the fan inlet (L). increasing the duct diameter before the fan, thereby increasing the radius of the bend. In this case, a converging section should be located at the fan inlet. Duct diameters should not exceed 1.5 times the fan inlet diameter.

L R

Fig. 2
1/2 d d 1/2 d

Fan capacity may be adversely affected when the space between 2 fans or between the fan inlet and the wall is too small (fig.2). The minimum distances shown should correct the problem.
d

Discharge connections
Bends, louver dampers connected directly to the fan outlet. Discharge velocities are not uniform at the fan outlet (fig. 3), which is why duct system components installed immediately downstream of the fan will cause high pressure drops. A good duct layout should have components installed at a minimum distance of: 3x 4 (a x b) In certain installations where it is necessary to install ductwork components near to the fan outlet, the capacity loss may be minimized by the use of a diverging duct section immediately after the outlet (fig. 4). The length of the section should be such that its discharge velocity equals the mean fan inlet velocity measured in the plane of the cone.

from the fan outlet, shown as Le in fig. 3.

Fig. 3

Fig. 4
L

Le

Outlet Free
With discharge velocities not being uniform at the fan outlet as shown, an additionnal pressure loss will be incurred, the magnitude of which will depend on the size of fan used, is to be added when the fan discharges directly into a plenum as the cross sectional area of the duct is larger than fan discharge area.

axb

39

Ancillaries

Standard ancillaries
1 Inlet Flange
(optional on Centripal L). Meets ISO 13351 requirements. Inlet diameters from 315 to 1600 mm sized on the R20 system.

Optionnal ancillaries
10 Grease nipples and exhaust holes 11 Casing Drain
20/27 male thread stub with cap. Not available on 270 orientations.

16 Inlet Vane Control Unit


(see our Gyropal literature).

17 Silencer
Cylindrical silencer, available with or without pod (on request).

2 Outlet Flange
Meets ISO 13351 requirements.

12 Matching flange
(see Inlet and Outlet Flange specifications). Supplied with bolts for installation.

18 Cylinder-type Filter
Disposable cartridge type inlet filter with 90 % efficiency rating.

3 Casing access Door


Bolted access door.

19 Anti-vibration Mountings 13 Safety Wire Guard


Meets ISO 13852 requirements. Anti-vibration mountings for installation under fan feet.

Standard ancillaries for belt-drive arrangement


4 Belt-Drive
Oversize V-Belt and cast iron sheave type sized to ISO 5292. Drive meets ISO 4184.

Spot welded stainless steel AISI 204, factory fitted.

20 Electric Motor
(all types and models).

14 Matching flange
(see Inlet and Outlet Flange specifications). Supplied with bolts for installation.

21 Inverter drive speed controller


(frequency converter).

5 Shaft Guard
Bolted onto bearing supports. Simplifies bearinf cap disassembly.

15 Flexible connection sleeve and deflector


Flexible connection sleeve Class M1 fire rated flexible connections designed for continuous operation at temperatures in excess of 300 C and operating pressures from 9,500 Pa to +15,000 Pa. Circular inlet sleeves flanged at both ends. Outlet sleeves rectangular or rectangularcircular and flanged at both ends, with the circular section sized to the fan inlet diameter. Deflector Required to protect flexible connection sleeves against extremely high or low pressures and heavily dust-laden air.

22 Damper
(on request)

6 Cooling Impeller Guard


Bolted onto bearing supports. Integral air slots.

7 Drive Guard
Bolted onto the casing base. Integral air slots and two inspection doors for speed and belt checks.

8 Belt Tensioning System


Located under the motors mount for quick and easy motor repositioning.

9 Bearings
Plummer block bearing type. Ball or roller bearings fitted as a function of operating conditions and size to ISO 281 for a useful life of 40,000 hours at maximum shaft speed.

40

17

13

22 6 21 15 5

14 3 10

2 9

19

20

11

12

16

13

15

17

18

41

Centripal EU fans
A new range developed with the latest IT tools including Finite Element Analysis.

A laboratory with a full compliment of measurement equipment: over-speed installation, fatigue tests, test rigs for measuring fan performance, noise and vibrations, according to the latest international standards.

42

Solyvent in the Flkt Woods Group:


Created in 1919, Flkt Solyvent Ventec has been a reference on the industrial ventilation market, in France and world-wide, for "Heavy Duty Applications"(Cement, Power, Steel, Petrochemical), as well as "Light Industrial Applications" (process fans and building ventilation). Flkt Solyvent Ventec offers a comprehensive range of centrifugal and axial flow fans, in either standard design, adapted to customer needs, or completely developed to technical specifications. The continuous development of product ranges, material employed or production tools allow Solyvent to be the "Centre of Excellence for Centrifugal fans" within the Flkt Woods Group. ISO 9000 V 2000 certification shows the committment of Solyvent in its quality process management.

43

Light Industry Building Air Climate


Flkt Solyvent-Ventec Flkt Woods AB Kung Hans vg la Rpublique 143, rue de 12 SE-192 68 SOLLENTUNA B.P. 67 SwedenMeyzieu Cedex France 69882 Tel: t + 33 (0) 4 72 45 13 00 +46 8 626 49 00 Fax:+46 8(0) 4 72 45 13 42 f + 33 626 73 10

Heavy Industry Industry Air Movement


Flkt Solyvent-Ventec Flkt Woods Limited Tufnell Way 30, rue Paul Sabatier Colchester, Essex B.P. 23 United Kingdom 71102 Chalon/Sane Cedex France Tel: (0) 3 85 41 73 11 t +33 +44 1206 544122 Fax:+44 85 41 73 22 f +33 (0) 3 1206 574434

Flkt Woods reserves its rights to modify the technical datas described in the document anytime. Informations are not contractual. Should you need any further information, please contact the local agent in your country.

44

TS-JPG - CSP - (V - 09/2007) - printed in France.

w www.flaktwoods.com

Вам также может понравиться