Вы находитесь на странице: 1из 8

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.

com Ultra Slim DC Power Supplies

RK-80 series

NEW

Ultra Slim DC Power Supplies


Sharp Versatile

www.matsusada-us.com

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com

Ultra Slim DC Power Supplies


RK-80 series is DC regulated power supply which has two time wider output setting range. For example standard 80W 36V model is enable to set up to 2.2A current (80W 36V), but RK-80 is enable to set maximum 5A, and has both setting range of 36V/2.2A and 16V/5A. Further more, the size 1/3, and weight is 1/5 of standard 80W power supply. Featuring OVP, OCP, 3 individual presets and locking function, RK-80 is high cost performance model.

NEW

(124mm)

4.88"

10.63"
(270mm)

RK-80 series
(35mm)

1.38"

Compact and light weight space saving design

80

80L

80M 80H

4 different models with various output voltages Power factor correction and universal input

For wider output range


RK-80L:16V/10A RK-80M:110V/1.3A RK-80:36V/5A RK-80H:320V/0.5A

With low noise switching method ideal for research purpose

Various operations by connecting multiple power supplies, such as master/slave, is possible.

New user-friendly functions


Useful new feature of variable setting range RK-80 36V/2.2A

New and useful functions and stylish front panel design!

Quick access to the function needed


No.1
Preset setting is automatically displayed when output is off.

16V/5A

No.2

OCP is added for more safety operation.

Set voltage/current value within 80W, then turn on output

*Not automatic range change which can output 80W all the time. Resetting is required.
02

No.3

Quick lock with one touch action. Two selectable lock options.

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com


LINEUP
AC Input Ripple Temperature coefficient(ppm/C) Output voltage Output current Output MODEL Input Voltage Input Current (typ) Power factor (typ) CV CC (V) (A) Power(W) (mVrms) (mArms)
0 to 16 0 to 36 0 to 110 0 to 320 0 to 10 0 to 5 0 to 1.3 0 to 0.5

Weight (typ)

RK-80L 80 RK-80 RK-80M RK-80H

5 5 10 20

10 5 2 1 100 200 85 to 264VAC 50/60Hz 1

AC in AC in 115V 230V 1A 0.5A 99%

0.9kg

When 115VAC Maximum Output

MULTI SETTING FUNCTION


Function to memorize 3 different voltage and current settings in addition to standard preset function. No need to adjust the output when different setting, and convenient function for production inspection process or testing which require frequent data taking.

DELAY TRIGGER FUNCTION


Function to output ON/OFF of total 32 units from one master unit. (when master/slave) * It is possible to delay the ON/OFF time, and simultaneous ON/OFF setting is possible as well. Ideal function for application which require time delay for ON/OFF setting.
Memory a
OUTPUT ON (From Master) Master OUTPUT OFF (From Master)

1 Press down SET 2 Select a memory with 3 buttons

t1

t5

Memory b

Slave1 t2 Slave2 t3 t7 t6

3 Set voltage and current

Memory c
Slave3 t4 Up to 32 units t8

*setting range of t1 to t8 is 0.0s to 99.9s

*Master/Slave function is available on the model with -LGmb option. TWO MODE LOCK FUNCTION
Function to select two different lock functions for two different purpose."Full Lock" locks all the function on front panel, and "Normal Lock" locks all the function except for ON/OFF. "Full Lock" mode shall be good in case mis-operation have to be completely avoided, and "Normal Lock" mode shall be good in case to avoid mis-operation but secure the way for emergency stop of power supply. You can select the best mode according to your level of "Security", (in both modes, emergency stop is possible with Power Switch.)

Full LOCK Lock all the function other than 9 reset lock mode, and effective for purpose to avoid misoperation when controlled.

Normal LOCK Lock voltage and current setting dial, and effective for purpose to avoid changing output setting by mistake or when easy emergency stop is required.

03

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com


Remote switch ON/OFF
5V or VCE

REMOTE FUNCTIONS

DIMENSIONS inch (mm)


side

0.89"(22.7)

10.63"(270)

0.16"(4)

* +S(common)
Output ON OFF Relay SHORT OPEN

Open collector V CE V CE 0.4V 2V

*+S is common. So external control voltage shall be input with +S


as reference. Otherwise it can cause failure.

Sink current 1mA

Remote sensing
Compensate the voltage drop (V0-VL) due to resistance of output lead or drop of stability by contact resistance. (maximum 0.5V)
+S

front
1.38"(35)
CV

back
LS+ LS+S + + -S

-S
4.88"(124)

V
CC

+
R VO IO

Load

A
SET OUTPUT OVP/
OCP

LOCK

VL

INPUT AC 100V-240V 50/60Hz

FUNCTIONS
1 2

0.31"(8)

Output voltage and OVP setting display Output current and OCP setting display Remote programming display
Light up when output voltage/current control in remote mode.

Front panel

Rear panel

3 4 15

Output display
Light up when output is on.

1 2 3 4 5

7 16 8 9 10 11 18 17

OUTPUT ON/OFF switch Monitor terminal

To be used to turn output on/off when local mode as well resetting protection functions.

6 7 8 9 10

Constant voltage operation mode display Constant current operation mode display PRESET switch OVP/OCP switch LOCK switch OUTPUT voltageOVP setting dial OUTPUT currentOCP setting dial Power ON/OFF switch
This has priority over all operations for safety reason.

12

11 12

13 6

13 14 19 15 16 17 18 19

14

LS switch(remote switch) +Sense OUTPUT terminal -Sense AC inlet

04

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com


SPECIFICATION
Output Control CV Mode : By rotary encoder on front panel
Setting resolution of output voltage is 1/256 of rated maximum voltage

Operation Temp 0C to 40C Storage Temp -40C to +85C Storage humidity 20% to 80% (non-condensing) Isolation voltage 250V-DC (Positive or Negative terminal grounding)

CC Mode : By rotary encoder on front panel


Output current setting accuracy is 1/256 of rated maximum output current. Remote control is option. See OPTION for remote control function.

Output Function Wide output range, automatic limit setting at 80W for voltage and current
In CV mode output current drop down when output power is more than 84.05W In CC mode output voltage drop down when output power is more than 84.05W

Lock Function Lock function locks the output voltage and current setting Output Display Voltage : 3-digit digital meter. *Accuracy is 0.5% FS 2 digits Current : 3-digit digital meter. *Accuracy is 0.5% FS 2 digits
(*Accuracy of preset setting is 1% FS 2 digits)

Protection

Over voltage protection (OVP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum voltage Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control) Over current protection (OCP) : Cut off the output at set value Setting range : appx. 5% to110% of rated maximum current Setting : By front panel rotary encoder Reset : By output ON/OFF switch or remote switch (manual control) Over temperature protection. (OTP) : Cut off output at abnormal inside temperature. Reset(after temperature get down to normal temperature) : Output ON/OFF switch or Remote switch (manual control) Input brownout(ACF). Blackout protection Output is cut off when input voltage decreased. Reset (when normal voltage value or recovery from blackout) Manual recovery by OUTPUT switch or remote switch for blackout protection(re-output protection function). Automatic recovery when blackout protection is canceled. Sense reverse connection

ACCESSORIES
Input AC cable 2.5m single phase 3pin type(1) Instruction manual(1) Ground plate(1)

Other Functions Remote switch ON/OFF (TTL or external relay), Remote sensing Delay trigger: Individual setting of ON delay and OFF delay (0.0 to 99.9sec) Multi setting function: Voltage and current memory "a", "b" and "c" setting in addition to standard voltage and current preset

Ground plate

*For safer operation connect ground plate and output terminal.

SERIES OPERATION PARALLEL OPERATION


RK-80 power supply of same model number can be connected in series or parallel to increase output voltage or current.

Series operation
PS1 V1 PS2 V2 0V
[caution] Total output voltage is to be up to 250V. Therefore for models with output voltage of over 250V, series operation cannot be conducted. Output current is to be the smallest current of those.

Parallel operation
PS1 - + Load + PS1

Split operation
- + +Vout 0V -Vout

- +

Vout V1+V2

- +

PS2

- +

PS2 -

- +

Please keep all the settings of voltage the same. Output current will be the summation of each current. [caution] Please keep OVP level of power supply maximum to prevent any damage.

[caution] In case of +- operation, the remote connector is connected to negative output terminal. So never connect other remote control to the connector.

05

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com


OPTION
-LUs1 :USB Interface Board
Enable digital control via USB
RK-80

* 1 *2

-LGmb :Digital Interface Board *1

*2

Enable digital control via GPIB/ RS-232C/ RS-485 as well as one control with Master/Slave function.

USB
GPIB
When controlling several RK-80 power supplies via USB, a USB hub will be required between the PC and RK-80 power supplies.

CO-G32m
A

RK-80

One control function *3 via Master/Slave

GPIB enables control of up to 14 CO-G32m modules.

Master

32 units can be connected to one CO-G32m.

A
Slave

Converter
CO-MET2-9 CO-MET2-25 CO-MET4-25
RS-232C RS-485

*5 *6
A

Up to 32

A CO-M cable
One 2 meter cable is provided per unit. Please notify your sales representative if you need a longer cable or additional cables.

Dsub Modular jack

-LRmf :Remote multi function *1


Output control

CV, CC
+S(common)

Remote control, it operates 3 range switchable mode as follows.


or

model

Switch number
1

Range
High Middle Low High Middle Low High Middle Low High Middle Low

Rated output voltage


16V 10V 8V 36V 27V 16V 110V 80V 60V 320V 250V 160V

Rated output current


5A 8A 10A 2.2A 3A 5A 0.7A 1A 1.3A 200mA 300mA 500mA

RK-80L Vout . Iout 0 to MAX Vcon . Icon 0 to about 10V R 0 to about 10k@ RK-80

2 3 1 2 3 1

RK-80M

2 3 1

RK-80H

2 3

can * 1) Either -LGmb, -LUs1, -LRmf USBbe selected.interface, please refer date sheet of CO series. specification and digital * 2) For detailed Function whenof 3) Delay triger be *@@ set voltage and current master/slave canunit.set individually . It is also possible to cancel one control function except for output by changing Remote/Local, @and @ @ @ preset for each external control voltage * 4) +S is common. SoMetal RS-232C module. shall be input with +S as reference. Otherwise it can cause failure. * 5) Previous model is Metal RS-485 module. 6) Previous model is * Add above L mark to the model number when ordering@ {e.g} RK-80-LGmb alphabetical order@ -LGmb, -LRmf, -LUs1 cannot be ordered together.

*
06

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com


AC INPUT CABLE
CABLE TYPE 1 (standard)
125V / 10A

CABLE TYPE 3
250V / 10A

CABLE TYPE 4
250V / 10A

RK-80 series Accessory Kit

Various accessories are available for convenient use of the unit. Rack mount holder
10 Units/1 rack holder, and can be placed in a cabinet. Easy to take one unit out. Best suitable for a system operation. With fan unit.

Book stand
For one unit operation...

Binder
For the applications which require 2 to 6 units combination. Dual, triple and quad multiple operation is possible.
needed *Cooling fan is 3 units for more than combination.

*Power supply is not included in the accessories.

07

Simpo PDF Password Remover Unregistered Version - http://www.simpopdf.com

FAX

USA/canada : 1-888-652-8651 other countries : 1-81-75-229-6366

Customer Inquiry Sheet (RK-80 series)


Please copy this page and fax to above fax number after filling out form below. What product are you interested in?
RK-80L RK-80 RK-80M RK-80H

<option>
-LGmb (GPIB,RS-232C,RS-485) -LUs1(USB I/F) -LRmf(analog I/F)

I would like...
a quotation an explanation of product a demonstration

You are currently


introducing one interested in applying for budget other ( )

Give us your requirement / comment.

Contact information.
Address: State: Zip:

Company name:

Dept.:

Title:

Name:

Tel:

Fax:

E-mail:

For products

www.matsusada.com/product

For contact

www.matsusada.com/contact

San Jose Office : 2570 N.First Street Suite 200 San Jose, CA 95131 New York Office : 80 Orville Drive Suite 100 Bohemia, NY 11716 Dallas Office : 5430 LBJ Freeway, Suite 1200 Dallas, TX 75240 International Office : Kyoto-City, Kyoto Japan @

Tel: +1-408-273-4573 Tel: +1-631-244-1407 Tel: +1-972-663-9336 Tel: +81-75-229-6355

Fax: +1-408-273-4673 Fax: +1-631-244-1496 Fax: +1-972-663-9337 Fax: +81-75-229-6366

Headquarters : 745 Aoji-cho Kusatsu Shiga 525-0041 Japan Tel: +81-77-561-2111 Fax: +81-77-561-2113

1117-01A

Вам также может понравиться