Вы находитесь на странице: 1из 82

TABLE OF CONTENTS

Revised 09/07/11

Table of Contents
1.1-1.16 DISHwASHErS

1/2

PLANNING GUIDE
10.1-10.6
10.1 -10.3 10.4 -10.6

wALL OvENS

Distinctive Single (DO) Distinctive Double (DO) Discovery Single (EO/MOH/MOV) Discovery Double (EO/MOH/MOV) Renaissance Single (EOR/MOR) Renaissance Double (EOR/MOR) Renaissance Single (RO/ROV) Renaissance Double (RO/ROV)

1.1-1.2 1.3-1.4 1.5-1.6 1.7-1.8 1.9-1.10 1.11-1.12 1.13-1.14 1.15-1.16

24 Front Control Panel DDWF24S 24 Hidden Control Panel EDWH/IDWH

rEFrIGErATION

wArmING DrAwErS

Epicure, Millennia , Integrated Millennia (ETT/MET)

2.1-2.3 3.1-3.3
3.1-3.3

Epicure Built-In Wine-Beverage cooler (EF24) 11.1 Epicure Outdoor Refrigerator (OF24) 11.2 36 Freestanding Glass 3-Door 11.3 36 Freestanding (EF/IF 3-Door) 11.4-11.7 42, 48 Built-In (EF/IF) 11.8-11.13 36 Freestanding with Dispenser (EF36IWF) 11.14

11.1-11.14

2.1-2.3

ELECTrIC COOkTOPS GAS COOkTOPS

mICrOwAvES

Epicure Slide-In (EG) Drop-In (SGM) Renaissance Drop-In (RGC) Distinctive Slide-In (DRT) Distinctive Drop-In (DCT)

4.1-4.21

4.1-4.4 4.5-4.9 4.10-4.13 4.14-4.17 4.18-4.21

Standard Type, Stainless Steel (DMW2420S) Trim Kits for Above (AMTK/AOMTK) Standard Type, Black Glass (DMT2420BK) Trim Kits for Above (AMTK/AOMTK) Convection Type (DCM24) Trim Kits for Above (ACTK/AOCTK) Standard Type, Over Range Mount (PMOR3021) Convection Type, Over Range Mount (PCOR30) 24" Microwave-In-A-Drawer (MMD24) 30" Microwave-In-A-Drawer (MMD30/MMDV30)

12.1-12.7
12.1 12.1 12.2 12.2 12.3 12.3 12.4 12.5 12.6 12.7

rANGES

30 Epicure All Gas (ER30G) 36 Epicure All Gas (ER36G) 30 Epicure Dual Fuel (ER30D) 36, 48 Epicure Dual Fuel (ER36D/ER48D) 30 Millennia Electric (MRES30) 30 Distinctive Dual Fuel (DR30D)

5.1-5.15

5.1-5.3 5.4-5.6 5.7-5.9 5.10-5.11 5.12-5.13 5.14-5.15

OUTDOOr GrILLS

Epicure (OB/OBS) 13.1-13.3 Built-In Trim kit for OB/OBS Series Grill (OBGT) 13.4 Outdoor Grill Carts, OB/OBS Series Grill (OBC) 13.5

13.1-13.5

BACkGUArDS

DUCT PLANNING GUIDE HOODS


Millennia Chimney Style, Wall Mount (DHW) Millennia Island Style (DHI) Glass Wall Mount (PHW) Epicure/Millennia Wall Mount (EH, EHR, MH) Integrated Ventilation System (IVS, IVSR) Custom Hood Liner (IHL)

6.1 7.1-7.8
7.1 7.2 7.3 7.4-7.6 7.7 7.8

Backguard, Stand-Alone (AEB)

14.1
14.1

rAISED vENTS

Epicure Slim Chassis (ERV, PRV) Epicure for ER 36", 48" Ranges (ERV-ER) Standard Chassis (RV)

8.1-8.13

8.1-8.3 8.4-8.6 8.7-8.13

BLOwErS

Cabinet Style for RV Series Raised Vents (CABP) 9.1 In-Line (ILHSF) 9.2-9.3 Remote (REMP) 9.4-9.6

9.1-9.6

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

X.1

TABLE OF CONTENTS
Revised 09/07/11

Table of Contents
CI.1-CI.27

2/2

PLANNING GUIDE

COmBINATION INSTALLATIONS

Drop-In Gas Cooktop/Raised Vent/Single Wall Oven CI.1 Drop-In Electric Cooktop/Raised Vent/Single Wall Oven CI.2 Drop-In Gas Cooktop/Slim Raised Vent/Single Wall Oven CI.3 Drop-In Electric Cooktop/Slim Raised Vent/Single Wall Oven CI.4 Single Wall Oven/Drop-In Cooktop CI.5 Raised Vent/30 Epicure Range CI.6 Raised Vent/36-48 Epicure Range CI.7 Slim Raised Vent/Millennia Range CI.8 CI.9 Slim Raised Vent/Epicure Slide-In Cooktop Slim Raised Vent/Distinctive Slide-In Cooktop CI.10 Drop-In Gas Cooktop/Raised Vent CI.11-CI.12 CI.13 DCT Drop-In Gas Cooktop/Raised Vent Drop-In Electric Cooktop/Raised Vent CI.14 Drop-In Gas Cooktop/Slim Raised Vent CI.15-CI.16 Drop-In Electric Cooktop/Slim Raised Vent CI.17 CI.18 Warming Drawer/Drop-In Cooktop Warming Drawer/Slide-In Cooktop CI.19 Warming Drawer (stacked)/Slide-In Cooktop CI.20 Warming Drawer (side-by-side)/Slide-In Cooktop CI.21 Microwave/Warming Drawer/Distinctive or Renaissance CI.22 Wall Oven Microwave/Warming Drawer CI.23 Microwave/Distinctive or Renaissance Wall Oven/ CI.24 Warming Drawer Microwave/Discovery Wall Oven/Warming Drawer CI.25 Microwave/Warming Drawer/Discovery Wall Oven CI.26 Discovery Wall Oven/Microwave In-A-Drawer/ Warming Drawer CI.27

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

X.2

DO
Document # PG01-007 Revised 05/25/10 Page 1/2

Single, Distinctive wall Oven


Product tolerances: 1/16 (1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

L Utility cutout

Top of chassis B F G

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

A
mODEL DO130

Control panel front Chassis Notch Side View

K E M

Conduit: 60 (152 cm) long Top of chassis

21 1/8 (53.7 cm)

(A) Overall Width 29 3/4 (75.6 cm)

(B) Chassis Width 28 3/8 (72.1 cm)

(C) Overall Height 28 7/16 (72.4 cm)

(D)* Chassis Height 27 1/2 (69.9 cm)

(E) Control Panel Overlay 15/16 (2.4 cm)

* To top of chassis notch behind control panel (F) Utility Cutout Width 5 (12.7 cm) (G) Utility Cutout Height 5 (13.3 cm) (H) Utility Cutout Depth 6 (15.2 cm) (J) Control Panel Depth 1 (2.5 cm) (K) Notch Depth 1 5/8 (4.1 cm) (L) Chassis Depth 24 (61.0 cm) (M) Notch Height 1 (2.5 cm)

ELECTRICAL SPECIFICATIONS Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire,*** 30 Amp. Total Connected Load 5.3 kW (23 Amp.)

*** Two 120 Vac hot (L1 and L2), one neutral, one ground The above specifications are for reference only. See the appliance data plate for exact specifications.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.1

DO
Document # PG01-007 Revised 05/25/10 Page 2/2

Single, Distinctive wall Oven


Cabinet/countertop tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

1 (2.5 cm) Min. to combustibles

1 1/2 (3.8 cm) typical counter 36 (91.4 cm)

R
Recommended electrical location 4 typical toe kick

3/4 (1.9 cm) support platform

1 (2.5 cm) Min. to combustible floor

SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr

1 (2.5 cm) Min. to bottom of cabinet door

Recommended electrical location

Minimum Interior Cabinet Depth: 24 (61.0 cm)

(N) Minimum Cabinet Width 30 (76.2 cm)


R 3/4 (1.9 cm) support platform

(P) Minimum Cut Out Width 28 (72.4 cm)

(R) Minimum Cutout Height 27 5/8 (70.2 cm)

1 (2.5 cm) Min. to top of cabinet door

Alternate electrical location

31 1/4 (79.4 cm) recommended

4 typical toe kick

SINGLE wALL OvEN - CUTOUT DImENSIONS

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.2

DO
Document # PG01-008 Revised 05/25/10 Page 1/2

Double, Distinctive wall Oven


Product tolerances: 1/16 (1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

Top of chassis

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

Utility cutout

F G H

A
mODEL DO230

21 1/8 (53.7 cm)

Control panel front Chassis Notch Side View

K E M

Top of chassis
(A) Overall Width 29 3/4 (75.6 cm)

Conduit: 60 (152 cm) Long

(B) Chassis Width 28 3/8 (72.1 cm)

(C) Overall Height 49 15/16 (126.8 cm)

(D)* Chassis Height 49 1/16 (124.6 cm)

(E) Control Panel Overlay 15/16 (2.4 cm)

* To top of chassis notch behind control panel (F) Utility Cutout Width 5 (12.7 cm) (G) Utility Cutout Height 5 (13.3 cm) (H) Utility Cutout Depth 6 (15.2 cm) (J) Control Panel Depth 1 (2.5 cm) (K) Notch Depth 1 5/8 (4.1 cm) (L) Chassis Depth 24 (61.0 cm) (M) Notch Height 1 (2.5 cm)

ELECTRICAL SPECIFICATIONS Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire,** 40 Amp. Total Connected Load 7.8 kW (33 Amp.)

** Two 120 Vac hot (L1 and L2), one neutral, one ground. The above specifications are for reference only. See the appliance data plate for exact specifications. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.3

DO
Document # PG01-008 Revised 05/25/10 Page 2/2

Double, Distinctive wall Oven


Cabinet/countertop tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

1 (2.5 cm) min. to bottom of cabinet door

Recommended electrical location

R P

3/4 (1.9 cm) support platform

1 (2.5 cm) Min. to top of drawer face

4 typical toe kick

9 5/8 (24.4 cm) recommended

DOUBLE wALL OvEN - CUTOUT DImENSIONS

(N) Minimum Cabinet Width 30 (76.2 cm)

(P) Minimum Cut Out Width 28 (72.4 cm)

(R) Minimum Cutout Height 49 1/8 (124.8 cm)

Minimum Interior Cabinet Depth: 24 (61.0 cm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.4

EO, mOH, mOv


Document # PG01-001 Revised 01/25/11 Page 1/2

27 and 30 Inch wide, Single, Discovery wall Ovens WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
Dedicated Circuit Required 240 Vac, 4-wire*, 60Hz, 30 Amp. Total Connected Load 4.6 kW (19.5 Amp.) Approximate Shipping Weight 240 lbs.

PLANNING GUIDE

Product tolerances: 1/16 (1.6 mm), unless otherwise stated.

EO - Epicure 3 11/16 (9.4 cm)

MOH/MOV - Millennia 3 5/16 (8.4 cm)

1 1/4 (3.2 cm)

1 1/4 (3.2 cm)

* Two 120 Vac hot (L1 and L2), one neutral, one ground.

HANDLE DImENSIONS - SIDE vIEw

C 1 1/4 (3.2 cm) B E F

Top of chassis H D

G Utility cutout

22 11/16 (57.6 cm)

Control panel front Chassis notch side view

L J K A Top of chassis

66 (167.6 cm) Flexible conduit

Model EO127 MOH127 MOV127 EO130 MOH130 MOV130

A 27 (68.6 cm)

H 25 3/8 (64.4 cm)

27 15/16 (71.0 cm) 30 (76.2 cm)

23 3/8 (59.4 cm)

2 5/16 (5.9 cm)

7 3/8 (18.7 cm)

6 3/8 (16.2 cm)

27 3/8 (69.5 cm) 28 3/8 (72.0 cm)

9/16 (1.4 cm)

1 (2.5 cm)

1 7/8 (4.6 cm)

PrODUCT DImENSIONS

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.5

EO, mOH, mOv


Document # PG01-001 Revised 01/25/11 Page 2/2

27 and 30 Inch wide, Single, Discovery wall Ovens

PLANNING GUIDE

Cutout tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated.

Recommended electrical location 1 (2.5 cm) min. to combustibles


1 1/2 (3.8 cm) typical counter 36 Typical (91.4 cm)

4 (10.2 cm) min. between cutout A B 3/4 (1.9 cm) support platform 4 typical toe kick (shown) A B 3/4 (1.9 cm) support platform Alternate electrical locations

1 (4.5 cm) min. to combustible floor

CUTOUT DImENSIONS SIDE-BY-SIDE UNDEr-COUNTEr INSTALLATION

Model EO127
Recommended electrical location

B 25 1/2 (64.8 cm)

C 27 (68.6 cm)

MOH127 MOV127 EO130 MOH130 MOV130 27 7/16 (69.7 cm)

28 1/2 (72.4 cm)

30 (76.2 cm)

1 (2.5 cm) min. clear to bottom of door

CUTOUT DImENSIONS

B 3/4 (1.9 cm) support platform

Alternate electrical location


1 1/2 (3.8 cm) typical counter 36 Typical (91.4 cm)

1 (2.5 cm) min. to combustibles

1 (4.5 cm) min. clear to top of door for heat exhaust

A B 3/4 (1.9 cm) support platform Recommended electrical location

31 1/4 (79.4 cm) recommended (may be altered)

1 (4.5 cm) min. to combustible floor 4 typical toe kick (shown)

4 typical toe kick (shown)

CUTOUT DImENSIONS UNDEr-COUNTEr INSTALLATION

NOTES: 1. 2. 24 (61.0 cm) minimum interior cabinet depth. Back of cabinet may need to be removed. 3/4 (1.9 cm) support platform (flush with cutout).

3. 4.

1/8 (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers. Two (2) Single Ovens are not approved in a stack configuration.
www.dacor.com Phone: (800) 793-0093

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

1.6

EO, mOH, mOv


Document # PG01-002 Revised 01/25/11 Page 1/2

27 and 30 Inch wide, Double, Discovery wall Ovens WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
Dedicated Circuit Required 240 Vac, 4-wire*, 60 Hz, 50 Amp.

PLANNING GUIDE
Total Connected Load 9.25 kW (38.9 Amp.) Approximate Shipping Weight 415 lbs.

* Two 120 Vac hot (L1 and L2), one neutral, one ground.

Product tolerances: 1/16 (1.6 mm), unless otherwise stated.

Top of chassis C 1 1/4 (3.2 cm) E F H D

Utility cutout

Control panel front Chassis notch side view

L J K
Top of chassis A

22 11/16 (57.6 cm)

66 (167.6 cm) Flexible conduit

Model EO227 MOH227 MOV227 EO230 MOH230 MOV230

A 27 (68.6 cm)

H 25 3/8 (64.4 cm)

51 1/16 (129.7 cm) 30 (76.2 cm)

23 3/8 (59.4 cm)

2 5/16 (5.9 cm)

7 3/8 (18.7 cm)

6 3/8 (16.2 cm)

50 1/2 (128.3 cm) 28 3/8 (72.0 cm)

9/16 (1.4 cm)

1 (2.5 cm)

1 7/8 (4.6 cm)

PrODUCT DImENSIONS

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.7

EO, mOH, mOv


Document # PG01-002 Revised 01/25/11 Page 2/2

27 and 30 Inch wide, Double, Discovery wall Ovens


Cutout tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated.

PLANNING GUIDE

C
EO - Epicure 3 11/16 (9.4 cm)

MOH/MOV - Millennia 3 5/16 (8.4 cm)

Recommended electrical location

1 1/4 (3.2 cm)

1 1/4 (3.2 cm)

1 (2.5 cm) min. clear to bottom of door


HANDLE DImENSIONS - SIDE vIEw

A B

Model EO227 MOH227

B 25 1/2 (64.8 cm)

C 27 (68.6 cm)

1 (4.5 cm) min. clear to top of door for heat exhaust

3/4 (1.9 cm) support platform 9 5/8 (24.4 cm) recommended (may be altered)

MOV227 EO230 MOH230 MOV230

50 9/16 (128.4 cm) 28 1/2 (72.4 cm) 30 (76.2 cm)

4 typical toe kick (shown)

CUTOUT DImENSIONS

NOTES: 1. 2. 3. 24 (61.0 cm) minimum interior cabinet depth. Back of cabinet may need to be removed. 3/4 (1.9 cm) support platform (flush with cutout). 1/8 (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.8

EOr, mOr
Document # PG01-003 Revised 05/25/10 Page 1/2

27, 30, 36 wide, Single, renaissance wall Ovens


All tolerances: 1/16 (1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

L Utility cutout

Top of chassis B* F G

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
(A) Overall (B)* Chassis Width Width 26 7/8 (68.3 cm) 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) 25 3/8 (64.5 cm) 28 3/8 (72.1 cm) 34 3/8 (87.3 cm) (C) Overall Height 28 7/16 (72.4 cm) 28 1/8 (71.4 cm) (D)** Chassis Height 27 1/2 (69.9 cm) 27 1/4 (69.2 cm) (E) Control Panel Overlay 15/16 (23.8 cm) 7/8 (2.2 cm)

Model Number

EORS127/ MORS127 EORS130/ MORS130 EORS136

Light cover

A Conduit: 60 (152 cm) Long E M Top of chassis

* Width at light covers on sides ** To top of chassis notch behind control panel Model Number EORS127 MORS127 EORS130 MORS130 EORS136 240 Vac 60 Hz., 4-wire***, 30 Amp. 5.0 kW (20.8 Amp.) 5.3 kW (22 Amp.) Dedicated Circuit Requirements Total Connected Load

Control panel front Chassis Notch Side View

*** Two 120 Vac hot (L1 and L2), one neutral, one ground The above specifications are for reference only. See the appliance data plate for exact specifications. (F) Utility Cutout Width (G) Utility Cutout Height 5 (13.3 cm) (H) Utility Cutout Depth 6 (15.2 cm) (J) Control Panel Depth 1 (2.54 cm) (K) Notch Depth 1 1/8 (2.9 cm) (L) Chassis Depth 24 (61.0 cm) (M) Notch Height 1 (2.5 cm)

All models

5 (12.7 cm)

1 (2.5 cm) 3 3/8 (8.6 cm)

1 (2.5 cm)

HANDLE DImENSIONS

Epicure

Millennia (Handle is integral)

21 1/8

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.9

EOr, mOr
Document # PG01-003 Revised 05/25/10 Page 2/2

27, 30, 36 wide, Single, renaissance wall Ovens


All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

Minimum Interior Cabinet Depth: 24 (61.0 cm)

1 (25 mm) Min. to combustibles

1 1/2 (3.8 cm) typical counter 36 (91.4 cm)

R
Recommended electrical location 4 typical toe kick

3/4 (1.9 cm) support platform

1 (2.5 cm) Min. to combustible floor

SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr

1 (2.5 cm) Min. to bottom of cabinet door

Recommended electrical location

Model Number EORS127/ MORS127 EORS130/ MORS130 EORS136

(N) Minimum Cabinet Width 27 (68.6 cm) 30 (76.2 cm) 36 (91.4 cm)

(P) Minimum Cut Out Width 25 (64.8 cm) 28 (72.4 cm)) 34 (87.6 cm)

(R) Minimum Cut out Height

3/4 (1.9 cm) support platform

27 5/8 (70.2 cm) 27 (69.9 cm)

1 (2.5 cm) Min. to top of cabinet door

Alternate electrical location

31 1/4 (79.4 cm) recommended

4 typical toe kick

SINGLE wALL OvEN - CUT OUT DImENSIONS

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.10

EOr, mOr
Document # PG01-004 Revised 05/25/10 Page 1/2

27, 30, 36 wide, Double, renaissance wall Ovens


All tolerances: 1/16 (1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

B*

Top of chassis

Utility cutout

F G H

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
(A) Overall (B)* Chassis (C) Overall Width Width Height 26 7/8 (68.3 cm) 29 7/8 (75.9 cm) 25 3/8 (64.5 cm) 28 3/8 (72.1 cm) (D)** Chassis Height (E) Control Panel Overlay 7/8 (2.2 cm)

Model Number EORX227/ MORX227

Light cover
D

EORX230/ MORX230

49 15/16 (127.0 cm)

49 1/16 (124.6 cm)

Light cover

X = Number of convection ovens: S = single, D = double * Width at light covers on sides ** To top of chassis notch behind control panel Model Number EORS227/ MORS227 Dedicated Circuit Requirements 240 Vac 60 Hz, 4-wire***, 40 Amp. 240 Vac 60 Hz, 4-wire***, 50 Amp. Total Connected Load 7.8 kW (33 Amp.) 10.0 kW (42 Amp.)

EORS230/ MORS230 EORD227/ MORD227 EORD230/ MORD230

Control panel front Chassis Notch Side View

K E M

Top of chassis

Conduit: 60 (152 cm) Long

*** Two 120 Vac hot (L1 and L2), one neutral, one ground The above specifications are for reference only. See the appliance data plate for exact specifications. (H) Utility Cutout Depth 6 (15.2 cm) (J) Control Panel Depth 1 (2.5 cm) (K) Notch Depth 1 1/8 (2.9 cm) (L) Chassis Depth 24 (61.0 cm) (M) Notch Height 1 (2.5 cm)

(F) Utility Cutout Width All models 5 (12.7 cm)

(G) Utility Cutout Height 5 (13.3 cm)

1 (2.5 cm) 3 3/8 (8.6 cm)

1 (2.5 cm)

HANDLE DImENSIONS

Epicure

Millennia (Handle is integral)

21 1/8

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.11

EOr, mOr
Document # PG01-004 Revised 05/25/10 Page 2/2

27, 30, 36 wide, Double, renaissance wall Ovens


All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

1 (2.5 cm) min. to bottom of cabinet door

Recommended electrical location

R P

3/4 (1.9 cm) support platform

1 (2.5 cm) Min. to top of drawer face

4 typical toe kick

9 5/8 (24.4 cm) recommended

DOUBLE wALL OvEN - CUT OUT DImENSIONS

Model Number EORX227/ MORX227 EORX230/ MORX230

(N) Minimum Cabinet Width 27 (68.6 cm)

(P) Minimum Cut Out Width 25 (64.8 cm)

(R) Minimum Cut-out Height

49 1/8 (124.8 cm) 30 (76.2 cm) 28 (72.4 cm)

X = Number of convection ovens: S = Single, D = Double

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.12

rO130, rOv130
Document # PG01-009 Revised 09/07/11 Page 1/2

30 Inch, Single, renaissance wall Oven


Product tolerances: 1/16 (1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

K Utility cutout

Top of chassis B F G

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

A Conduit: 60 (152 cm) long E Top of chassis

Control panel front Control panel side view


(A) Overall Width 29 7/8 (75.9 cm) (F) Utility Cutout Width 6 1/4 (15.9 cm) (B) Chassis Width 28 3/8 (72.1 cm) (G) Utility Cutout Height 4 3/4 (12.1 cm)

21 1/8

(C) Overall Height 28 5/8 (70.2 cm)

(D) Chassis Height 26 5/8 (67.6 cm)

(E) Control Panel Overlay 1 (2.5 cm) (K) Chassis Depth 23 5/8 (60.0 cm)

ELECTRICAL SPECIFICATIONS Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire,* 30 Amp. Total Connected Load 6.0 kW (25.0 Amp.)

(H) Utility Cutout Depth 7 3/4 (19.7 cm)

(J) Control Panel Depth 1 3/16 (3.0 cm)

* Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2. The above specifications are for reference only. See the product data plate for exact specifications.

1 1/8 (2.9 cm) 3 1/2 (8.9 cm) 3 3/16 (8.1 cm)

1 1/8 (2.9 cm)

HANDLE DImENSIONS

Epicure

Millennia (Order kit #AMOH30)) www.dacor.com Phone: (800) 793-0093

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

1.13

rO130, rOv130
Document # PG01-009 Revised 09/07/11 Page 2/2

30 Inch, Single, renaissance wall Oven


Cabinet tolerances: +1/16 (+1.6 mm) -0, unless otherwise stated

PLANNING GUIDE

1 (2.5 cm) min. to combustibles

1 1/2 (3.8 cm) typical counter 36 typ. (91.4 cm)


R

Recommended electrical location 4 typical toe kick

1 (2.5 cm) min. to bottom of cabinet door

Recommended electrical location

3/4 (1.9 cm) support platform

1 (2.5 cm) min. to combustible floor

SINGLE wALL OvEN - INSTALLED UNDEr COUNTEr

Minimum interior cabinet depth: 24 (61.0 cm)

3/4 (1.9 cm) support platform

(N) Minimum Cabinet Width 30 (76.2 cm)

(P) Minimum Cut Out Width 28 1/2 (72.4 cm)

(R) Minimum Cutout Height 26 7/8 (68.3 cm)

1 (2.5 cm) min. to top of cabinet door

Alternate electrical location

31 1/4 (79.4 cm) recommended

4 typical toe kick


SINGLE wALL OvEN - CUTOUT DImENSIONS

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.14

rO230, rOv230
Document # PG01-010 Revised 08/26/11 Page 1/2

30 Inch, Double, renaissance wall Oven


Product tolerances: 1/16 (1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

K Utility cutout

Top of chassis B F G H

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

21 1/8

Control panel front Control panel side view


(A) Overall Width 29 7/8 (75.9 cm) (F) Utility Cutout Width 6 1/4 (15.9 cm)

Top of chassis

Conduit: 60 (152 cm) Long

1 1/8 (2.9 cm) 3 1/2 (8.9 cm) 3 3/16 (8.1 cm)

1 1/8 (2.9 cm)

(B) Chassis Width 28 3/8 (72.1 cm) (G) Utility Cutout Height 4 3/4 (12.1 cm)

(C) Overall Height 49 7/8 (126.7 cm)

(D) Chassis Height 49 (124.5 cm)

(E) Control Panel Overlay 7/8 (2.2 cm) (K) Chassis Depth 23 5/8 (60.0 cm) Epicure Millennia (Order kit #AMOH30)) HANDLE DImENSIONS

(H) Utility Cutout Depth 7 3/4 (19.7 cm)

(J) Control Panel Depth 1 3/16 (3.0 cm)

ELECTRICAL SPECIFICATIONS Dedicated Circuit Requirements 240 Vac 60 Hz., 4-wire,* 60 Amp. Total Connected Load 11.6 kW (48.6 Amp.)

* Two 120 Vac hot (L1 and L2), one neutral, one ground. Fuse/circuit breaker on both L1 and L2. The above specifications are for reference only. See the product data plate for exact specifications. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

1.15

rO230, rOv230
Document # PG01-010 Revised 08/26/11 Page 2/2

30 Inch, Double, renaissance wall Oven


Cabinet tolerances: +1/16 (+1.6 mm) -0, unless otherwise stated

PLANNING GUIDE

1 (2.5 cm) min. to bottom of cabinet door

Recommended electrical location

3/4 (1.9 cm) support platform

1 (2.5 cm) min. to top of drawer face

4 typical toe kick

9 5/8 (24.4 cm) recommended

DOUBLE wALL OvEN - CUTOUT DImENSIONS

(N) Minimum Cabinet Width 30 (76.2 cm)

(P) Minimum Cut Out Width 28 1/2 (72.4 cm)

(R) Minimum Cutout Height 49 1/8 (124.8 cm)

Minimum interior cabinet depth: 24 (61.0 cm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

1.16

Document # PG02-002

ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD


24, 27, 30, 36, wide warming Drawers

Revised 01/24/11 Page 1/3

PLANNING GUIDE
Total Connected Load 4.0 Amp. @ 120 Vac, 60 Hz. Minimum Ambient Operating Temperature 32F (0C)

Product tolerances: 1/16 (1.6 mm) unless otherwise stated

ERWD 3 1/2" (8.9 cm) 1 1/8" (2.9 cm) 3 7/16" (8.7 cm)

EWD

Electrical Circuit Required 120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit

1" (2.5 cm)

10 1/8 (257 mm)

MRWD30B (only) 1 7/16" (3.7 cm)

MWDH/V All other MRWD series 3 1/4" (8.3 cm) 1" (2.5 cm) 1" (2.5 cm)

A
DrAwEr FACE DImENSIONS (MWD SerieS ShoWn)

HANDLE DImENSIONS - SIDE vIEw

Mounting hole 9 places

40 (101.6 cm) 3-prong 120 Vac power cord

B C

1/2" (1.3 cm) 10" (25.4 cm)

9" (22.9 cm)

Chassis without drawer inserted

Chassis

23 3/8 (59.4 cm)

1/2" (1.3 cm)


CHASSIS DImENSIONS

Model ERWD27

(A) Drawer Face Width 27 (68.6 cm) 30 (76.2 cm) 24 (61.0 cm) 27 (68.6 cm) 30 (76.2 cm) 36 (91.4 cm) 26 3/4 (67.9 cm) 29 3/4 (75.6 cm) 27 (68.6 cm) 30 (76.2 cm) 27 (68.6 cm) 30 (76.2 cm)

(B) Chassis Face Width 26 5/8 (67.6 cm) 29 5/8 (75.2 cm) 23 5/8 (60.0 cm) 26 5/8 (67.6 cm) 29 5/8 (75.2 cm) 35 5/8 (90.5 cm) 26 5/8 (67.6 cm) 29 5/8 (75.2 cm) 26 5/8 (67.6 cm) 29 5/8 (75.2 cm) 26 5/8 (67.6 cm) 29 5/8 (75.2 cm)

(C) Chassis Width 25 1/4 (64.1 cm) 28 1/4 (71.8 cm) 22 1/4 (56.5 cm) 25 1/4 (64.1 cm) 28 1/4 (71.8 cm) 34 1/4 (87.0 cm) 25 1/4 (64.1 cm) 28 1/4 (71.8 cm) 25 1/4 (64.1 cm) 28 1/4 (71.8 cm) 25 1/4 (64.1 cm) 28 1/4 (71.8 cm)

5/64" (2 mm) Drawer open 23 13/16 (60.5 cm)

ERWD30 EWD24 EWD27 EWD30 EWD36 MRWD27 MRWD30 MWDH27 MWDH30

OvErALL DImENSIONS - TOP vIEw (EwD SErIES SHOwN)

MWDV27 MWDV30

wArmING DrAwEr OvErALL DImENSIONS Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

2.1

Document # PG02-002

ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD


24, 27, 30, 36, wide warming Drawers

Revised 01/24/11 Page 2/3

PLANNING GUIDE
Total Connected Load 4.0 Amp. @ 120 Vac, 60 Hz. Minimum Ambient Operating Temperature 32F (0C)

Product tolerances: 1/16 (1.6 mm) unless otherwise stated

Electrical Circuit Required 120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit

C B

Chassis

E 5/16 (8 mm)

Drawer open

DrAwEr FACE DImENSIONS (iWD/oWD SerieS ShoWn)

Mounting hole, 9 places


OvErALL DImENSIONS - IwD/OwD SErIES TOP vIEw

40" (101.6 cm) 3 prong 120 Vac power cord

**

** ** ** G

Chassis without drawer installed ** = OWD24 mounting holes


CHASSIS DImENSIONS (iWD/oWD ShoWn)

Model IWD24 IWD27 IWD30 OWD24

(A) Dimension Drawer Face Width 22 5/16 (56.7 cm) 25 5/16 (64.3 cm) 28 5/16 (71.9 cm) 22 1/2 (57.1 cm)

(B) Dimension Chassis Width 22 1/4 (56.5 cm) 25 1/4 (64.1 cm) 28 1/4 (71.8 cm) 22 1/2 (57.1 cm)

(C) Dimension Chassis Face Width 22 3/8 (56.8 cm) 25 3/8 (64.5 cm) 28 3/8 (72.1 cm) 22 1/2 (57.1 cm)

(D) Dimension Drawer Face Height 8 15/16 (22.7 cm) 11 7/8 (30.2 cm)

(E) Dimension Chassis Depth 23 3/8 (59.4 cm) 20 (50.8 cm)

(F) Dimension Drawer Depth 23 13/16 (60.5 cm) 18 (45.7 cm)

(G) Dimension Chassis Height 9 1/16 (23.0 cm) 11 7/8 (30.2 cm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

2.2

Document # PG02-002

ErwD, EwD, IwD, mrwD, mwDv, mwDH, OwD


24, 27, 30, 36 wide warming Drawers

Revised 01/24/11 Page 3/3

PLANNING GUIDE WARNING

Cabinet/countertop tolerances: +1/16 (+1.6 mm) -0 unless otherwise stated

36" typ. (91.4 cm)

Warming drawer Warming drawer 120 Vac electrical outlet

C C

3/4" min.* (1.9 cm) D 3/4" min.* (1.9 cm)

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
Mounting platform must be 3/4" (1.9 cm) thick and support 100 lbs.

A B

27"/30"/36" Dacor single wall oven D Warming drawer Warming drawer 120 Vac elect. 120 Vac elect. C D C
36" typ. (91.4 cm)

Cooktop

1 1/2" (3.8 cm) Typical countertop Warming drawer C 3/4 min.* (1.9 cm)

A B

120 Vac electrical outlet

Toe kick A

3/4" min.* (1.9 cm)


(B) Min. Width to Adjacent Doors/ Drawers 27 1/4 (69.2 cm)* 30 1/4 (76.8 cm)* 24 1/4 (61.6 cm)* 27 1/4 (69.2 cm)* 30 1/4 (76.8 cm)* 36 1/4 (92.1 cm)* ** ** ** 27 (68.6 cm)* 30 (76.2 cm)* 27 1/4 (69.2 cm)* 30 1/4 (76.8 cm)* 27 1/4 (69.2 cm)* 30 1/4 (76.8 cm)* 24 1/4 (61.6 cm)***

Model ERWD27 ERWD30 EWD24 EWD27 EWD30 EWD36**** IWD24 IWD27 IWD30 MRWD27 MRWD30 MWDH27 MWDH30 MWDV27 MWDV30 OWD24*****

(A) Cutout Width 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) 22 1/2 (57.2 cm) 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) 34 1/2 (87.6 cm) 22 1/2 (57.2 cm) 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) 25 1/2 (64.8 cm) 28 1/2 (72.4 cm) 22 5/8 (57.5 cm)

(C) Cutout Height 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 9 1/8 (23.2 cm) 11 15/16 (30.3 cm)

(D) Min. Vertical Gap Between Cutouts 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* NA 1 1/16 (2.7 cm) 1 1/16 (2.7 cm) 1 1/16 (2.7 cm) 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* 1 1/4 (3.2 cm)* NA

Min. Cutout Depth

24 (61.0 cm)

20 1/8 (51.1 cm)

* Bare minimum spacing to allow for ventilation and avoid scraping on ERWD, EWD, MRWD, MWDH and MWDV series models. ** On IWD series models or OWD24 without the optional front panel kit: The chassis and the drawer faceplate are smaller than the cutout. The custom front panel mounts to the drawer faceplate. The height and width of the custom front panel must exceed the appropriate cutout dimensions (A and C above) to cover the hole. Allow 1/4" minimum additional space on the top, bottom and sides from the custom front panel edge to prevent scraping against adjacent doors, drawers and the countertop. *** OWD24 with optional factory front panel kit only. Bare minimum spacing shown to avoid scraping. Gap above and below cutout is 3/4 minimum. See ** above for OWD24 with custom front panel. **** Model EWD36 cannot be installed above or below another warming drawer (any type). ***** Model OWD24 cannot be installed above, below or adjacent to a wall oven or warming drawer (any type). Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

2.3

ETT304-1, ETT365-2, mET304 and mETB365-1


Document # PG03-001 Revised 05/06/10 Page 1/3

30 Inch and 36 Inch wide, millennia Electric Cooktops


Product tolerances: 1/16 (1.6 mm) unless otherwise noted

PLANNING GUIDE WARNING

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

30 1/4" * (768 mm)

4" (102 mm) Chassis height

21 1/4" * (540 mm)

19 3/8" (495 mm)

28 3/8" (721 mm)

36 1/4" * (921 mm)

4" (102 mm) Chassis height

PrODUCT DImENSIONS - ETT304-1 AND mET304 (ETT304-1 SHOwN)


19 3/8" 21 1/4" * (495 mm) (540 mm) 34 3/8" (873 mm)

PrODUCT DImENSIONS - ETT365-2 AND mETB365-1 (ETT365-2 SHOwN) * For units with stainless steel trim, other units may be up to 1/8" less.

Model No. ETT304-1 ETT365-2 MET304 METB365-1

Electrical Circuit Required 240 Vac, 60 Hz, 40 Amps. 240 Vac, 60 Hz, 40 Amps. 240 Vac, 60 Hz, 40 Amps. 240 Vac, 60 Hz, 50 Amps.*

Total Connected Load* 6.9 kW (29 Amps.) 9.1 kW (38 Amps.) 6.9 kW (29 Amps.) 9.6 kW (40 Amps.)

Minimum Supply Wire Size Line and Ground Connections

No. 8 AWG

* For reference only, See the product data label on bottom of unit for exact specifications. ELECTrICAL SUPPLY rEqUIrEmENTS

NOTES: 1. The cooktop is supplied with a flexible, 48 inch long power conduit consisting of two (2) insulated hot lead conductors (L1 and L2) and one (1) insulated ground conductor. There is no neutral connection. All leads are copper. The conduit is connected to the right corner of the cooktop. Do not connect the ground wire to neutral. Tested in accordance with the latest edition of ANSI Z21.1 and U.L. 858 Standard for household cooking appliances. These cooktops are not approved for recessed installation.
www.dacor.com Phone: (800) 793-0093

2. 3.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

3.1

ETT304-1, ETT365-2, mET304 and mETB365-1


Document # PG03-001 Revised 05/06/10 Page 2/3

30 Inch and 36 Inch wide, millennia Electric Cooktops


All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

Allow a minimum of 6 inches (152 mm) clearance between the top of the countertop and any combustible surface below, including the upper edge of a drawer below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets.

When installing model ETT365-2 or METB365-1 and the bottom of the chassis is to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.

Cooktop cutout in top of cabinet

A
Model ETT304-1, MET304 ETT365-2, METB365-1

6 (152 mm) Min. clearance to combustible surfaces


(A) Minimum Under Counter Clearance (Width) 30 1/2 (775 mm) 36 1/2 (927 mm)
3/ 4

7 3/4 X 4 3/8 ventilation cut-outs in enclosure floor

1 1/2

1 1/2

3/ 4

UNDEr COUNTEr CLEArANCE

TOP vIEw vENTILATION CUTOUT

Rear wall

Model ETT304-1, MET304 ETT365-2, METB365-1

(B) Minimum Under Counter Clearance (Width) 28 3/4 (730 mm) 34 3/4 (883 mm)

6" (152 mm) Min. from mounting surface to combustibles below cooktop chassis B 19 3/4" Min. 2 1/4" Min. (502 mm) (57 mm) 1" Min. (25 mm) 6" (152 mm) Min. to combustible, side wall, both sides

COUNTErTOP CUTOUT (wITHOUT rAISED vENT)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

3.2

ETT304-1, ETT365-2, mET304 and mETB365-1


Document # PG03-001 Revised 05/06/10 Page 3/3

30 Inch and 36 Inch wide, millennia Electric Cooktops


All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

3/8 Min. (10 mm) flat countertop overhang required behind cutout Stiffener

Countertop

5/8 Min. (16 mm) flat countertop overhang required behind cutout Stiffener

Countertop

ETT or MET series cooktop Cabinet face 3/8 Min. (10 mm) space behind raised vent chassis to clear stiffener ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit

ETT or MET series cooktop Cabinet face 5/8 Min. (16 mm) space behind raised vent chassis to clear stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit

Floor
Erv AND Prv SErIES rAISED vENT INSTALLATION SIDE vIEw
D B E

Floor
rv SErIES rAISED vENT INSTALLATION SIDE vIEw

Rear wall

19 3/4" (502 mm)

Cabinet face

1" Min. (25 mm)

6" (152 mm) Min. from mounting surface to combustibles below cooktop chassis

6" Min. (152 mm)

6" Min. (152 mm)

COUNTErTOP CUTOUT (wITH rAISED vENT) TOP vIEw

COUNTErTOP CUTOUT (wITH rAISED vENT) ISO vIEw (E) Minimum Rear Countertop Overhang 3/8 (10 mm) 5/8 (16 mm) 3/8 (10 mm) 5/8 (16 mm)

Model/Configuration ETT304-1 or MET304 cooktop with ERV30 or PRV30 raised vent ETT304-1 or MET304 cooktop with RV30 raised vent ETT365-2 or METB365-1 cooktop with ERV36 or PRV36 raised vent ETT365-2 or METB365-1 cooktop with RV36 raised vent

(A) Cooktop Cutout Width 28 3/4 (730 mm)

(B) Raised Vent Cutout Width 27 3/4 (705 mm)

(C) Total Cutout Depth 22 1/2 (572 mm) 22 1/4 (565 mm) 22 1/2 (572 mm)) 22 1/4 (565 mm)

(D) Raised Vent Cutout Depth 2 3/4 (70 mm) 2 1/2 (64 mm) 2 3/4 (70 mm) 2 1/2 (64 mm)

34 3/4 (883 mm)

33 3/4 (857 mm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

3.3

EG366, EG486
Document # PG04-001 Revised 05/06/10 Page 1/4

36 Inch and 48 Inch wide Epicure Gas Cooktops WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
Circuit Required 120 Vac 60Hz, 15 Amp. (3 wire)

PLANNING GUIDE
Total Connected Load 0.25 Amp @ 120 Vac, 60 Hz

ELECTrIC CIrCUIT rEqUIrEmENTS

Product tolerances: 1/16 (1.6 mm) unless otherwise noted

GAS SUPPLY PrESSUrE rEqUIrEmENTS* Gas Type Natural Gas Propane (LP) Manifold Pressure 5 Water Column 10 Water Column Minimum Gas Supply Pressure 6 Water Column 11 Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2 (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486).

Combustible rear wall


PrODUCT DImENSIONS - ISO vIEw A - Width EG366 EG486 35 7/8 (911 mm) 47 7/8 (1216 mm)

2 1/2 (64 mm) Min. to combustible rear wall

28 (711 mm) 27 (686 mm) 26 (660 mm)

Trim: 7/16 (11 mm) thick

CABINET/COUNTErTOP SIDE vIEw wITHOUT BACkGUArD

1 1/2 (38 mm) cooking surface height (grate level) above countertop

7 3/4 (197 mm)

Combustible rear wall Backguard mandatory if gap from back of cooktop to combustible wall is less than 2 1/2

4 (102 mm)

Power cord 32 long

5/8 (16 mm)

3/4 gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2 (51 mm) from chassis bottom
PrODUCT DImENSIONS - SIDE vIEw Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. CABINET/COUNTErTOP SIDE vIEw wITH BACkGUArD

www.dacor.com

Phone: (800) 793-0093

4.1

EG366, EG486
Document # PG04-001 Revised 05/06/10 Page 2/4

36 Inch and 48 Inch wide Epicure Gas Cooktops


Cabinet tolerances: +1/16, -0 (+1.6 mm, -0) unless otherwise noted.
10 (254 mm) to combustible side wall Min. both sides 1 1/2 (38 mm) typical countertop thickness

PLANNING GUIDE

1/2 (13 mm) overhang, both sides B

7 3/4 (197 mm) Recommended gas and electrical service location, consult local code

Cooktop platform 1 (25 mm) Min. thickness

36 (914 mm) typical

CABINET/COUNTErTOP DImENSIONS - FrONT vIEw


13 (330 mm) max.3

Model No. EG366


Hood

B 36 (914 mm) 48 (1219mm)

C 36 (914 mm)* 42 (1067 mm)** 48 (1219 mm)* 54 (1372 mm)**

EG486

* Minimum ** Recommended
See note 2

18 (457 mm) Min.1, 3

30 (762 mm) Min.1 Top of finished counter

Cutout for utility access

CABINET/COUNTErTOP DImENSIONS ISO vIEw

1 Vertical to combustible surface from cooktop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10 (254mm) from the edge of the cooktop.

Continued on following pages...

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.2

EG366, EG486
Document # PG04-001 Revised 05/06/10 Page 3/4

36 Inch and 48 Inch wide Epicure Gas Cooktops


Cutout tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

Gas and electrical connections at right rear section of chassis

Gas connection and power cord may be routed through bottom or back of chassis
Increase countertop and overhang additional 2 1/2 (64 mm) Min. for combustible rear wall above countertop Non-combustible rear wall, rear of mounting platform

3/8 (13 mm) countertop overhang 1/2 (13 mm) countertop overhang 24 5/8 (625 mm) Gas/electrical utility cut-out in right rear corner of mounting platform 8 W X 6 D (203 mm X 152 mm), if gas and electrical are routed through bottom

10 (254 mm) min. to combustible wall above countertop, both sides 1/2 (13 mm) countertop overhang Countertop

C L
11 7/16 (291 mm) Countertop

Hole 1/2 dia. (13 mm), 2 places, through platform for hold down bolts 1 thick mounting platform Min.

2 (51 mm) 1 (25 mm) Cabinet face below countertop overhang

C L

C L
B

C L

CABINET/COUNTErTOP CUTOUT DImENSIONS wITHOUT rAISED vENT - TOP vIEw

Model No. EG366 EG486

B - Cutout Width 36 (914 mm) 48 (1219 mm)

D - Hole Offset 16 5/8 (422 mm) 20 13/16 (529 mm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.3

EG366, EG486
Document # PG04-001 Revised 05/06/10 Page 4/4

36 Inch and 48 Inch wide Epicure Gas Cooktops


Cutout tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

2 5/8 (67 mm)

3/8 (10 mm) Min. countertop overhang

Non combustible rear wall recommended

E Open to below to allow for raised vent, gas and electrical connections 1/2 (13 mm) countertop overhang 24 5/8 15 (625 mm) (381 mm) 1 thick mounting platform Min.

10 (254 mm) Min. to combustible wall above countertop, both sides

C L

1/2 (13 mm) countertop overhang Countertop

Countertop

11 7/16 (291 mm)

Hole 1/2 dia. (13 mm), 2 places, through platform for hold down bolts

2 (51 mm) 1 (25 mm) D D Cabinet face below countertop overhang

C L

C L
B

C L

CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - TOP vIEw

3/8 Min. (10 mm) flat countertop overhang required behind cutout Countertop

Model No. EG366 EG486

Approved Raised Vent Models ERV36, PRV36 ERV48, PRV48

Stiffener EG366 or EG486 cooktop 3/8 Min. (10 mm) space behind raised vent chassis to clear stiffener Dacor approved raised vent IMPORTANT: See raised vent installation instructions for duct system layout/planning

IMPORTANT: Use only the raised vents specified.

Control panel Cabinet face

Model No.

B - Cutout Width 36 (914 mm) 48 (1219 mm)

D - Hole Offset 16 5/8 (422 mm) 20 13/16 (529 mm)

E - Raised Vent Cutout 33 1/2 (851 mm) 43 1/2 (1105 mm)

Minimum countertop height: 30 1/4" (768 mm)

EG366 EG486

CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - SIDE vIEw Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

4.4

SGm304, SGm365, SGm466


Document # PG04-004 Revised 01/27/11 Page 1/5

30, 36, 46 wide, Drop-in Gas Cooktops

PLANNING GUIDE WARNING

All tolerances 1/16 (1.6 mm), unless otherwise noted.

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

30" (76.2 cm)

1 5/8" (4.1 cm) bottom of base to cooking surface

4" (10.2 cm) chassis height

21" (53.3 cm)

19 1/2" * (49.5 cm)

27 5/8" * (70.2 cm)

PrODUCT DImENSIONS mODEL SGm304

* including embosses/screws in side of chassis

1 5/8" (4.1 cm) bottom of base to cooking surface 36" (91.4 cm)

4" (10.2 cm) chassis height

PrODUCT DImENSIONS mODEL SGm365


33 1/2" * (85.1 cm)

21" (53.3 cm)

19 1/2" * (49.5 cm)

* including embosses in side of chassis


46" (116.8 cm)

4" (10.2 cm) chassis height

1 5/8" (4.1 cm) bottom of base to cooking surface

44 5/8" * (113.3 cm) 19 1/2" * (49.5 cm)

21" (53.3 cm)

PrODUCT DImENSIONS mODEL SGm466

* including embosses/screws in side of chassis

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.5

SGm304, SGm365, SGm466


Document # PG04-004 Revised 01/27/11 Page 2/5

30, 36, 46 wide, Gas Cooktops


Electrical Requirements Gas Supply Requirements

PLANNING GUIDE

WARNING
To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owners responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed.
The cooktop is supplied with a factory installed, 40-inch, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. Be certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service.

Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Units equipped for LP operation have LP in the model number listed on the product data label. See the Chassis Bottom Diagram for label location. Units equipped for high altitude operation have an H at the end of the model number listed on the product data label. Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve. Models SGM304 and SGM365 come with a 1/2 regulator. Model SGM466 comes with a 3/4 regulator, approved for connection to a 1/2 house gas supply.

The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page. SGM304 SGM365 SGM466 Gas type Manifold pressure Natural 4 Water column 5 Water column 1/2 p.s.i. 0.25 Amp. (0.03 kW) 120 Vac, 60 Hz, 15 Amp. SGM304LP SGM365LP SGM466LP LPG 10 Water column 11 Water column 1/2 p.s.i. 0.25 Amp. (0.03 kW) 120 Vac, 60 Hz, 15 Amp.

Front of unit

Product data label

Min. gas supply pressure** Max. gas supply pressure Total connected load Circuit requirement

Gas inlet Electric cord


CHASSIS BOTTOm DIAGrAm

GAS AND ELECTrICAL rEqUIrEmENTS* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.6

SGm304, SGm365, SGm466


Document # PG04-004 Revised 01/27/11 Page 3/5

30, 36, 46 wide, Gas Cooktops


Cabinet and Countertop Layout

PLANNING GUIDE

WARNING
To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. Follow the countertop manufacturers instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.

Allow a minimum 1/4 (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.

1/4 (6 mm) min. clearance to combustible surfaces

Under Cabinet Clearances


Model SGM304 SGM365 SGM466 (B) Minimum* 29 (73.7 cm) 35 1/4 (89.5 cm) 46 (116.8 cm)

* To allow clearance for hold down brackets The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. Access to the gas shut-off valve and regulator when the unit is installed. Access to the electrical outlet when the cooktop is in place. The 40 (101.6 cm) power cord must be able to reach the electrical outlet Access to the underside of the cooktop for service and inspection purposes Clearance inside the cabinet to allow for proper hold down bracket installation.

Cabinet tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

Combustible overhead cabinets

The installation must allow for the following:

13" max.3 (33.0 cm)

18" min.1, 3 (45.7 cm)

Combustible surface to rear See cutout dimensions

2 30" min.1, (76.2 cm)

1 7/8" min. (4.8 cm)

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

Raised Vent Compatibility


If installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below:

7 1/2 (19.1 cm) min. to combustible side wall, above counter both sides Measured from cooking surface (top of cooktop grate). 2 If installing with an overhead vent hood, also check hood specifications for minimum required clearances. 3 Not applicable for cabinets more than a horizontal distance of 6 (15.2 cm) from edge of cooktop. Allow 7 1/2 (19.1 cm) from edge of cutout.
mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP Model SGM304 SGM365 SGM466 (A) Minimum 30 (76.2 cm) 36 (91.4 cm) 48 (121.9 cm) (A) Recommended 36 (91.4 cm) 42 (106.7 cm) 54 (137.2 cm)
1

Cooktop Models SGM304 SGM365 SGM466

Approved Raised Vent Models ERV30, PRV30 or RV30 ERV36, PRV36 or RV36 PRV46 or RV46

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.7

SGm304, SGm365, SGm466


Document # PG04-004 Revised 01/27/11 Page 4/5

30, 36, 46 wide, Gas Cooktops


Cutout Dimensions

PLANNING GUIDE

Cutout tolerances +1/16 (+1.6 mm), -0, unless otherwise noted

IMPORTANT: Be careful to use the correct cutout diagram (on page 5/5) to determine the countertop dimensions for the installation type. Carefully double check all dimensions against the table below and the correct diagram before cutting the countertop. Countertop Dimensions Installation Type SGM304 without raised vent SGM304 with ERV30 or PRV30 SGM304 with RV30 SGM365 without raised vent SGM365 with ERV36 or PRV36 SGM365 with RV36 SGM466 without raised vent SGM466 with PRV46 SGM466 with RV46 Cutout Diagram Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 1 (Square) Figure 2 (Notched) Figure 2 (Notched) (C) Min. 2 7/8 (7.3 cm) 3/8 (1.0 cm) 5/8 (1.6 cm) 2 7/8 (7.3 cm) 3/8 (1.0 cm) 5/8 (1.6 cm) 2 7/8 (7.3 cm) 3/8 (1.0 cm) 5/8 (1.6 cm) (D) 19 3/4 (50.2 cm) 22 1/2 * (57.2 cm) 22 1/4 * (56.5 cm) 19 3/4 (50.2 cm) 22 1/2 * (57.2 cm) 22 1/4 * (56.5 cm) 19 3/4 (50.2 cm) 22 1/2 * (57.2 cm) 22 1/4 * (56.5 cm) (E) 27 3/4 (68.6 cm) 27 3/4 (68.6 cm) 27 3/4 (68.6 cm) 33 5/8 (85.4 cm) 33 5/8 (85.4 cm) 33 5/8 (85.4 cm) 44 3/4 (113.7 cm) 44 3/4 (113.7 cm) 44 3/4 (113.7 cm) (F) NA NA NA NA NA NA NA 43 1/2 (110.5 cm) 43 1/2 (110.5 cm) (G) NA NA NA NA NA NA NA 5/8 (1.6 cm) 5/8 (1.6 cm) (H) NA NA NA NA NA NA NA 2 5/8 ** (6.7 cm) 2 5/8 ** (6.7 cm)

* Total cutout depth, accommodates both the cooktop and raised vent ** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).

3/8 min. (1.0 cm) flat countertop overhang required behind cutout Stiffener

Countertop
Stiffener

5/8 min. (1.6 cm) flat countertop overhang required behind cutout

Countertop

SGM series cooktop Cabinet face 3/8 min. (1.0 cm) space behind raised vent chassis to clear stiffener ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit

SGM series cooktop Cabinet face 5/8 min. (1.6 cm) space behind raised vent chassis to clear stiffener RV series raised vent: Check raised vent dimensions/specifications to determine proper fit 4 5/8 (11.7 cm) 9 7/8 (25.1 cm) with CABP3 blower installed

Floor
SIDE vIEw - SGm SErIES COOkTOP wITH Erv Or Prv SErIES rAISED vENT

Floor
SIDE vIEw - SGm SErIES COOkTOP wITH rv SErIES rAISED vENT

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.8

SGm304, SGm365, SGm466


Document # PG04-004 Revised 01/27/11 Page 5/5

30, 36, 46 wide, Gas Cooktops


Cutout tolerances +1/16 (+1.6 mm), -0, unless otherwise noted

PLANNING GUIDE

Rear wall

Vertical combustible surface 4 1/4" (10.8 cm) min. from mounting surface to combustibles below cooktop chassis C D E 7 1/2" (19.1 cm) min. to combustible side wall above countertop (both sides)

1 7/8" min. (4.8 cm)


FIGUrE 1 - SqUArE COUNTErTOP CUTOUT DIAGrAm

Rear wall

4 1/4" (10.8 cm) min. from mounting surface to combustibles below cooktop chassis

Vertical combustible surface G

F 7 1/2" (19.1 cm) min. to combustible side wall above countertop (both sides)

C D

1 7/8" min. (4.8 cm)


FIGUrE 2 - NOTCHED COUNTErTOP CUTOUT DIAGrAm Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.9

rGC304, rGC365
Document # PG04-005 Revised 01/25/11 Page 1/4

30, 36 wide renaissance Gas Cooktops


All tolerances 1/16 (1.6 mm) unless otherwise noted.

PLANNING GUIDE WARNING

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

30" (76.2 cm)

2 1/8" (5.4 cm) bottom of base to cooking surface

4" (10.2 cm) chassis height

21" (53.3 cm)

19 1/2" * (49.5 cm)

27 1/2" * (69.9 cm)

* including embosses in side of chassis


PrODUCT DImENSIONS - mODEL rGC304

36" (91.4 cm)

21" (53.3 cm)

4" (10.2 cm) chassis height

Axis2

19 1/2" * (49.5 cm) 2 1/8" (5.4 cm) bottom of base to cooking surface

33 5/8" * (85.4 cm)

* including embosses in side of chassis

PrODUCT DImENSIONS - mODEL rGC365 Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.10

rGC304, rGC365
Document # PG04-005 Revised 01/25/11 Page 2/4

30, 36 wide, renaissance Gas Cooktops


Electrical Requirements Gas Supply Requirements

PLANNING GUIDE

WARNING
To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owners responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed.
The cooktop is supplied with a factory installed, 40-inch power cord with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service.

Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Units equipped for LP operation have LP in the model number listed on the product data label. See the Chassis Bottom Diagram for label location. Units equipped for high altitude operation have an H at the end of the model number listed on the product data label. Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve. The regulator inlet accommodates a 3/4 gas line. The inlet to the cooktop itself is equipped with a 3/4 male NPT fitting.

The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page. RGC304 RGC365 Gas type Manifold pressure Min. gas supply Pressure** Natural 5 Water column 6 Water column 1/2 p.s.i. 0.25 Amp. (0.03 kW) 120 Vac, 60 Hz, 15 Amp. RGC304LP RGC365LP LPG 10 Water column 11 Water column 1/2 p.s.i. 0.25 Amp. (0.03 kW) 120 Vac, 60 Hz, 15 Amp.

Front of unit

Product data label

Max. gas supply pressure Total connected load

Gas inlet Electric cord


CHASSIS BOTTOm DIAGrAm

Circuit requirement

GAS AND ELECTrICAL rEqUIrEmENTS* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.11

rGC304, rGC365
Document # PG04-005 Revised 01/25/11 Page 3/4

30, 36 wide, renaissance Gas Cooktops


Cabinet and Countertop Layout

PLANNING GUIDE

WARNING
To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. Follow the countertop manufacturers instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.

Allow a minimum 1/4 (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.

1/4 (6 mm) min. clearance to combustible surfaces

Under Cabinet Clearances


Model RGC304 RGC365 (B) Min.* 29 (73.7 cm) 35 1/4 (89.5 cm)

* To allow clearance for hold down brackets The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. Access to the gas shut-off valve and regulator when the unit is installed. Access to the electrical outlet when the cooktop is in place. The 40 (101.6 cm) power cord must be able to reach the electrical outlet Access to the underside of the cooktop for service and inspection purposes Clearance inside the cabinet to allow for proper hold down bracket installation.

All tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

The installation must allow for the following:

Combustible overhead cabinets

13" max. (33.0 cm)

18" min. (45.7 cm)

1, 3

Combustible surface to rear See cutout dimensions

30" min. (76.2 cm)

1, 2

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

1 7/8" min. (4.8 cm)

Raised Vent Compatibility


If installing the cooktop with a raised vent, install only the approved Dacor model numbers specified below: Cooktop Model Approved Raised Vent Models ERV30, PRV30 or RV30 ERV36, PRV36 or RV36

See cutout dimensions


1 2

RGC304 RGC365

Measured from the cooking surface (top of cooktop grate). If installing with an overhead vent hood, also check the hood specifications for minimum required clearances. 3 Not applicable for cabinets more than a horizontal distance of 6 (15.2 cm) (5 1/2 (14.0 cm) for RGC365) from edge of cooktop. Allow 7 1/2 (19.1 cm) from cutout edge for RGC304 and 7 (17.8 cm) for RGC365.
mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP Model RGC304 RGC365 (A) Min. 30 (76.2 cm) 36 (91.4 cm) (A) Recommended 36 (91.4 cm) 42 (106.7 cm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.12

rGC304, rGC365
Document # PG04-005 Revised 01/25/11 Page 4/4

30, 36 wide, renaissance Gas Cooktops


Cutout Dimensions

PLANNING GUIDE

All tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

Rear wall Vertical combustible surface 4 1/4" (10.8 cm) min. from mounting surface to combustibles below cooktop chassis C D F E F

COUNTErTOP CUTOUT DImENSIONS Installation Type RGC304 with no raised vent RGC304 with ERV30 or PRV30 RGC304 with RV30 RGC365 with no raised vent RGC365 with ERV36 or PRV36 RGC365 with RV36

1 7/8" min. (4.8 cm)

Min. distance to combustible side wall above countertop (both sides)

(C) Min. 2 7/8 (7.3 cm) 3/8 (1.0 cm) 5/8 (1.6 cm) 2 7/8 (7.3 cm) 3/8 (1.0 cm) 5/8 (1.6 cm)

(D) 19 3/4 (50.2 cm) 22 1/2 (57.2 cm) 22 1/4 (56.5 cm) 19 3/4 (50.2 cm) 22 1/2 (57.2 cm) 22 1/4 (56.5 cm)

(E) 27 5/8 (70.1 cm)

(F) 7 1/2 (19.0 cm)

33 3/4 (85.7 cm)

7 (17.8 cm)

3/8 min. (1.0 cm) flat countertop overhang required behind cutout Stiffener

Countertop

5/8 min. (1.6 cm) flat countertop overhang required behind cutout Stiffener

Countertop

RGC series cooktop Cabinet face 3/8 min. (1.0 cm) space behind raised vent chassis to clear stiffener ERV or PRV series raised vent: check raised vent dimensions/specifications to determine proper fit

RGC series cooktop Cabinet face 5/8 min. (1.6 cm) space behind raised vent chassis to clear stiffener RV series raised vent: check raised vent dimensions/specifications to determine proper fit

Floor
SIDE vIEw - rGC SErIES COOkTOP wITH Erv/Prv SErIES rAISED vENT Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

Floor
SIDE vIEw - rGC SErIES COOkTOP wITH rv SErIES rAISED vENT

www.dacor.com

Phone: (800) 793-0093

4.13

DrT304S, DrT366S
Document # PG04-003 Revised 02/03/11 Page 1/4

30 and 36 wide, Distinctive Series Slide-in Gas Cooktops WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

PLANNING GUIDE

Electrical and Gas Supply Requirements


ELECTRIC CIRCUIT REQUIREMENTS Circuit Required 120 Vac 60Hz, 15 Amp. (3 wire) Total Connected Load 1.0 Amp @ 120 Vac, 60 Hz.

Product Dimensions

GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Natural Gas Propane (LP) Manifold Pressure 5 Water Column 10 Water Column Minimum Gas Supply Pressure 6 Water Column 11 Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

Cabinet and Countertop Layout


Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2 (Figure 2). When installing a backguard, use only Dacor model numbers AEB3009 (DRT304S), AEB3609 or AEB3612 (DRT366S).

A
Product tolerances: 1/16 (1.6 mm) unless otherwise noted

Combustible rear wall 2 1/2 (6.4 cm) min. to combustible rear wall

COOKTOP WIDTH (A) DRT304S DRT366S 29 7/8 (75.9 cm) 35 7/8 (91.1 cm)

28 1/8 (71.4 cm) 25 7/8 (65.7 cm)

Trim: 1/2 (1.3 cm) thick

SIDE vIEw wITHOUT BACkGUArD

Combustible rear wall Backguard mandatory if gap from back of cooktop to combustible wall is less than 2 1/2

1 5/8 (4.1 cm) cooking surface height (grate level) above countertop

7 3/4 (19.7 cm)

4 (10.2 cm)

Power cord 32 (81.3 cm) long

5/8 min. (1.6 cm)


SIDE vIEw wITHOUT BACkGUArD

3/4 gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2 (5.1 cm) from chassis bottom
SIDE vIEw

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.14

DrT304S, DrT366S
Document # PG04-003 Revised 02/03/11 Page 2/4

30 and 36 wide, Distinctive Series Slide-in Gas Cooktops


Cabinet and Countertop Layout (Continued)
10 (25.4 cm) to combustible side wall min. both sides 1 1/2 (3.8 cm) typical countertop thickness

PLANNING GUIDE

Cabinet tolerances: +1/16, -0 (+1.6 mm, -0) unless otherwise noted.

1/2 (1.3 cm) overhang, both sides B

7 3/4 (19.7 cm) Recommended gas and electrical service location, consult local code

Cooktop platform 1 (2.5 cm) min. thickness

36 (91.4 cm) typical

CABINET/COUNTErTOP DImENSIONS - FrONT vIEw


13 (33.0 cm) max.3

Model No. DRT304S DRT366S

B 30 (76.2 cm) 36 (91.4 cm)

C 30 (76.2 cm)* 36 (91.4 cm)** 36 (91.4 cm)* 42 (106.7 cm)**

Hood

* Minimum ** Recommended

See note 2

NOTE: Model DRT304S is not approved for installation with a raised vent.
18 (45.7 cm) min.1, 3 30 (76.2 cm) min.1 Top of finished counter Cutout for utility access

CABINET/COUNTErTOP DImENSIONS ISO vIEw

1 Vertical to combustible surface from cooktop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10 (25.4 cm) from the edge of the cooktop.

Continued. on following page...

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.15

DrT304S, DrT366S
Document # PG04-003 Revised 02/03/11 Page 3/4

30 and 36 wide, Distinctive Series Slide-in Gas Cooktops


Cabinet and Countertop Layout (Continued)
Cutout tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

PLANNING GUIDE

Gas and electrical connections at right rear section of chassis

Gas connection and power cord may be routed through bottom or back of chassis
Increase countertop and overhang additional 2 1/2 (6.4 cm) min. for combustible rear wall above countertop Non-combustible rear wall, rear of mounting platform

3/8 (1.3 cm) countertop overhang 1/2 (1.3 cm) countertop overhang 24 5/8 (62.5 cm) Countertop Gas/electrical utility cut-out in right rear corner of mounting platform 8 W X 6 D (20.3 cm X 15.2 cm), if gas and electrical are routed through bottom

10 (25.4 cm) min. to combustible wall above countertop, both sides 1/2 (1.3 cm) countertop overhang Countertop

Hole 1/2 dia. (1.3 cm), 2 places, through platform for hold down bolts 1 thick mounting platform min.

2 (5.1 cm) 1 (2.5 cm) Cabinet face below countertop overhang

C L
B

CABINET/COUNTErTOP CUTOUT DImENSIONS wITHOUT rAISED vENT - TOP vIEw

Model No. DRT304S DRT366S

B - Cutout Width 30 (76.2 cm) 36 (91.4 cm)

D 13 3/8 (34.0 cm) 16 5/8 (42.2 cm)

E 10 1/8 (25.7 cm) 11 3/16 (28.4 cm)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.16

DrT304S, DrT366S
Document # PG04-003 Revised 02/03/11 Page 4/4

30 and 36 wide, Distinctive Series Slide-in Gas Cooktops


Cabinet and Countertop Layout (Continued)
2 5/8 (6.7 cm) 3/8 (1.0 cm) min. countertop overhang Non combustible rear wall recommended

PLANNING GUIDE

Cutout tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

F Open to below to allow for raised vent, gas and electrical connections 1/2 (1.3 cm) countertop overhang 24 1/2 15 (62.2 cm) (38.1 cm) E 1 (2.5 cm) thick mounting platform min.

10 (2.5 cm) min. to combustible wall above countertop, both sides

1/2 (1.3 cm) countertop overhang Countertop

Countertop

Hole 1/2 dia. (1.3 cm), 2 places, through platform for hold down bolts

2 (5.1 cm) 1 (2.5 cm) D


CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - TOP vIEw

C L
B
F - Raised Vent Cutout 33 1/2 (85.1 cm)

Cabinet face below countertop overhang

Model No.* DRT366S

B - Cutout Width 36 (91.4 cm)

D 16 5/8 (42.2 cm)

E 11 3/16 (28.4 cm)

NOTE: Gas and electrical connections may only be routed through the bottom of the cooktop when installed with a raised vent.

* Model DRT304 is not approved for use with a raised vent. ** Use only raised vent model specified. Raised vent is not compatible with DRT cooktops having a serial number starting with letters SA.

3/8 min. (1.0 cm) flat countertop overhang required behind cutout Stiffener 3/8 min. (1.0 cm) space behind raised vent chassis to clear stiffener Use Dacor raised vent, model ERV3615 only

28 5/16 (71.9 cm) Countertop

DRT366 cooktop

Control panel Cabinet face

Minimum countertop height: 30 1/4" (76.8 cm)

CABINET/COUNTErTOP CUTOUT DImENSIONS wITH rAISED vENT - SIDE vIEw

IMPORTANT: See raised vent installation instructions for duct system layout/planning

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.17

DCT305, DCT365
Document # PG04-006 Revised 08/19/11 Page 1/4

30 and 36 wide, Distinctive Series Drop-in Gas Cooktops WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

PLANNING GUIDE

Product tolerances 1/16 (1.6 mm) unless otherwise noted.

2" (5.1 cm) countertop to cooking surface 4" (10.2 cm) chassis height
Model DCT305 DCT365 (A) 30 (76.2 cm) 36 (91.4 cm) (B) 27 5/16 (69.4 cm) 33 5/16 (57.8 cm)

21" (53.3 cm)

Rear overhang 1 3/16 (3.0 cm) 19 9/32 (49.0 cm) Side View

Front overhang 17/32 (1.3 cm)

1 11/32 (3.4 cm) B Front View

1 11/32 (3.4 cm)

Product Dimensions
Front of cooktop

Front of unit

Power cord in

1/2 male NPT gas inlet*

1 3/4 (4.4 cm)

Chassis 1 3/4 (4.4 cm) 2 (5.1 cm) Top panel overhang

Power cord 42 (106.7 cm) long

1/2 male NPT gas inlet

*Gas inlet protudes 1/2 (1.3 cm) from bottom


UTILITY LOCATIONS Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. UTILITY DImENSIONS www.dacor.com Phone: (800) 793-0093

4.18

DCT305, DCT365
Document # PG04-006 Revised 08/19/11 Page 2/4

30 and 36 wide, Distinctive Series Drop-in Gas Cooktops


Electrical Requirements Gas Supply Requirements

PLANNING GUIDE

WARNING
To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owners responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician.
The cooktop is supplied with a factory installed, 42 inch power cord with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. Be certain to locate the electrical outlet so that the power may be easily disconnected if the unit needs service.

Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. Units equipped for LP operation have LP in the model number listed on the product data label. See the Chassis Bottom Diagram for label location. Units equipped for high altitude operation have an H at the end of the model number listed on the product data label. Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve. The regulator inlet accommodates a 3/4 gas line. The inlet to the cooktop itself is equipped with a 3/4 male NPT fitting.

The cooktop gas connection is located on the bottom of the cootktop in the back right corner as you face the front of the unit. See the Chassis Bottom Diagram on this page. DCT304_NG DCT365_NG Gas type Manifold pressure Natural 5 water column 6 water column 1/2 psi 0.25 Amp. (30 Watts) 120 Vac, 60 Hz, 15 Amp. DCT304_LP DCT365_LP LP gas 10 water column 11 water column 1/2 psi 0.25 Amp. (30 Watts) 120 Vac, 60 Hz, 15 Amp.

Front of unit

Product data label

Min. gas supply Pressure** Max. gas supply pressure Total connected load Circuit requirement

CHASSIS BOTTOm DIAGrAm

GAS AND ELECTrICAL rEqUIrEmENTS* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1 inch water column (249 Pa) above the specified manifold pressure.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.19

DCT305, DCT365
Document # PG04-006 Revised 08/19/11 Page 3/4

30 and 36 wide, Distinctive Series Drop-in Gas Cooktops


Cabinet and Countertop Layout

PLANNING GUIDE

WARNING
To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. Follow the countertop manufacturers instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system.

Allow a minimum 1/4 (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.

1/4 (6 mm) mimimum clearance to combustible surfaces

* Allows for clearance between hold down brackets


Model DCT305 DCT365 (B) Minimum 29 1/4 (74.3 cm) 35 1/4 (89.5 cm)

Cabinet tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. Access to the gas shut-off valve and regulator when the unit is installed. Access to the electrical outlet when the cooktop is in place. The 42 (106.7 cm) power cord must be able to reach the electrical outlet Access to the underside of the cooktop for service and inspection purposes Clearance inside the cabinet to allow for proper hold down bracket installation.

The installation must allow for the following:

13 max.3 (33.0 cm) 18 min.1, 3 (45.7 cm) Combustible surface to rear See cutout dimensions 1 5/8 min. (4.1 cm) See cutout dimensions Distance to combustible surfaces measured from cooking surface (top of cooktop grate). 2 If installing with an overhead range hood, check the hood specifications for minimum required clearances. 3 This specification does not apply for cabinets located greater than a horizontal distance of 5 1/2 (14.0 cm) from edge of cooktop. Allow 6 7/8 (17.5 cm) from cutout edge.
mINImUm rEqUIrED CLEArANCES ArOUND THE COOkTOP Model DCT305 DCT365 (A) Minimum 30 (76.2 cm) 36 (91.4 cm) (A) Recommended 36 (91.4 cm) 42 (106.7 cm)
1

30 min. (76.2 cm)

1, 2

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions.

Raised Vent Compatibility


Model DCT305 is not compatible with a raised vent. If installing cooktop model DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation of any other raised vent model may cause improper operation.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

4.20

DCT305, DCT365
Document # PG04-006 Revised 08/19/11 Page 4/4

30 and 36 wide, Distinctive Series Drop-in Gas Cooktops


Cutout Dimensions
Cabinet tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated

PLANNING GUIDE

Raised Vent Compatibility


If installing cooktop DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation other any other model raised vent may cause improper operation.

Rear wall Vertical combustible surface 4 1/4 (10.8 cm) min. from mounting surface to combustibles below cooktop chassis C D F 1 5/8 min. (4.1 cm) Minimum distance to combustible side wall above countertop (both sides) E F

Installation Type DCT305* DCT365 with no raised vent DCT365 with ERV3615 raised vent

(C) Minimum 3 1/4 (8.3 cm) 3 1/4 (8.3 cm) 3/8 (1.0 cm)

(D) 19 5/8 (49.9 cm) 19 5/8 (49.9 cm) 22 3/4 (57.8 cm)

(E) 27 5/8 (85.4 cm) 33 5/8 (85.4 cm)

(F) Minimum 6 7/8 (17.5 cm)

* Model DCT305 is not compatible with a raised vent

3/8 min. (1.0 cm) flat countertop overhang required behind cutout Stiffener

Countertop

DCT365 cooktop Cabinet face 3/8 min. (1.0 cm) space behind raised vent chassis to clear stiffener ERV3615 raised vent. Check raised vent dimensions/specifications to determine proper fit

Floor
SIDE vIEw - DCT365 COOkTOP wITH Erv3615 rAISED vENT Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

4.21

Er30G, Er30GI
Document # PG05-001 Revised 05/25/10 Page 1/3

30 wide, Epicure All Gas range


Electrical Circuit Required 120 Vac, 60 Hz, 15 Amps., dedicated, grounded Total Connected Load 4.0 Amps. @ 120 Vac, 60 Hz

PLANNING GUIDE WARNING

ELECTrICAL rEqUIrEmENTS

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances 1/16 (1.6mm) unless otherwise noted.

45 9/16 (1157mm) 28 9/16 (725mm) 27 1/16 (687mm) 26 1/8 (664mm) 24 (610mm) 1 1/8 (29mm)

Front of open door Front of handle Front edge of bullnose Front panel Rear of front panel Backguard thickness

NOTE: Neither model is compatible with a raised vent.

9 (229mm) Grates extend Backguard*** 1 above trim 1 9/16 (40mm)

6 (152mm) Backguard* 3 (76mm) Backguard*** 1 3/4 (44mm) Backguard**

ER30GI: 2 (51mm) Partial stainless steel side panel 3 (76mm) 35 (889mm) to 37 1/8 (943mm)

* Standard on model ER30G Optional on model ER30GI, NOT compatible with self-rimming installations ** Standard on model ER30GI Optional on model ER30G *** Optional on both models, NOT compatible with self-rimming installations ER30G is designed for freestanding installations. ER30GI is designed for installation in a recessed cabinet or island. ER30G is NOT equipped for self-rimming installation.

ER30G: Full stainless steel side panels

Product width: 29 7/8 (759mm)

Er30G/Er30GI OvErALL DEPTH DImENSIONS - SIDE vIEw

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.1

Document # PG05-001

Er30G, Er30GI
30 wide, Epicure All Gas range
A*
B

Revised 05/25/10 Page 2/3

PLANNING GUIDE
B 30 (762mm) Minimum 36 (914mm) Recommended C 37 1/8 (943mm) Maximum

All tolerances +1/16 -0 (+1.6mm, 0) unless otherwise noted.

30 1/16 (764mm)

* See the cutout dimensions below for self-rimming installations

NOTE: Self-rimming kit is included with model ER30GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back.
13 (330mm) Max.4

Non-combustible surface along back wall recommended 18 (457mm) Min.1, 4 30 (762mm) Min.1

Top of finished counter 10 (254mm Min. to combustible side walls above the range (both sides)

Note 2

Suggested location of utilities3

Vertical to combustible surface from range grate level Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10 (254mm) from the edge of the range.
2

SLIDE-IN CUTOUT DImENSIONS


10 Min. (254mm) to any combustibles above counter both sides
10 Min. (254mm) rear wall or to any combustibles countertop edge above counter both sides 3/4 Min. (19mm) Countertop overhang

non comubustible rear wall recommended

29 1/4 (743mm) countertop opening 30 (762mm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets Countertop Height: Min: 34 3/4 (883mm) Max: 36 7/8 (937mm) Countertop Thickness: Max: 1 5/8 (41mm)

24 (610mm)

Countertop overhang 2 1/8 (54mm) Max.

29 1/4 (743mm) countertop opening 30 (762mm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets Countertop Height: Min: 34 3/4 (883mm) Max: 36 7/8 (937mm) Countertop Thickness: Max: 1 5/8 (41mm)

24 1/8 (613mm)

Countertop overhang 2 1/8 (54mm) Max.

SELF-rImmING CUTOUT DImENSIONS CABINET DEPTH ExACTLY 24 INCHES (Er30GI ONLY) Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

SELF-rImmING CUTOUT DImENSIONS CABINET DEPTH GrEATEr THAN 24 INCHES (Er30GI ONLY)

www.dacor.com

Phone: (800) 793-0093

5.2

Document # PG05-001

Er30G, Er30GI
30 wide, Epicure All Gas range

Revised 05/25/10 Page 3/3

PLANNING GUIDE

10 (254mm)

C L

12 (305mm)
12 1/2 (318 mm) to 14 5/8 (371 mm)

2 5/8 (67 mm)


BACk OF rANGE

2 1/2 (64mm) 1 (25mm) 3 1/2 C L (89mm)


UTILITY CLEArANCE BEHIND rANGE

GAS SUPPLY PRESSURE REQUIREMENTS Gas Type Natural LP Manifold Pressure* (WC) 5 10 Min. Gas Supply Pressure (WC) 6 11 Max. Input Pressure 1/2 p.s.i. 1/2 p.s.i.

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it). The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

10 (254mm)

www.dacor.com

Phone: (800) 793-0093

5.3

Er36G, Er36GI
Document # PG05-002 Revised 05/25/10 Page 1/3

36 wide, Epicure Gas range WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

PLANNING GUIDE
Total Connected Load 5.0 Amps. @120 Vac, 60 Hz,

Electrical Circuit Required 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, 3 prong electrical outlet

ELECTrICAL rEqUIrEmENTS

All tolerances 1/16 (1.6 mm) unless otherwise noted.

46 7/8 (1191 mm) 29 (736 mm) 27 13/16 (706 mm) 26 3/4 (679 mm) 24 5/8 (625 mm) Grates extend 1 1 above trim 2 (51 mm) 1 9/16 (40 mm) ER36GI: Partial stainless steel side panel 3 (76 mm)

Front of open door Front of handle Front edge of bull nose Front panel Rear of front panel7

9 (229 mm) 1 1/4 (32 mm) 19 (482 mm) D 15 1/4 (387 mm) B C

ER36G: Full stainless steel side panels Product Width: 35 7/8 (911 mm)

35 3/4 (908 mm) to 37 7/8 (962 mm)

(A) 1 3/4 (44 mm): Model AER36GLBG (low profile) 2 (B) 6 (152 mm): Model AER36GBG6 3, 5 (C) 9 (229 mm): Model AER36GBG9 4, 5 (D) 24 (610 mm): Model AER36GBG24 4, 5
Er36G/Er36GI AvAILABLE BACkGUArDS

Er36G/Er36GI DImENSIONS SIDE vIEw

NOTE: Neither model is compatible with raised vents.

NOTES: 1. 2. 3. 4. 5. 6. 7. Trim thickness is 1/4 (6 mm) with optional self-rimming kit installed (ER36GI only). Standard on model ER36GI. Optional on model ER36G. Standard on model ER36G. Optional on model ER36GI. Optional on both models. Not for use with self rimming installations. ER36G is not equipped for self-rimming installation. ER36G is designed for freestanding installations. ER36GI is designed for installation in a recessed cabinet or island. This dimension is shortened to 24 inches when the selfrimming kit is installed (ER36GI only).
www.dacor.com Phone: (800) 793-0093

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

5.4

Document # PG05-002

Er36G, Er36GI
36 wide, Epicure Gas range

Revised 05/25/10 Page 2/3

PLANNING GUIDE

All tolerances +1/16 -0 (+1.6 mm, 0) unless otherwise noted. A*


B

B 30 (762 mm) Minimum 36 (914 mm) Recommended

C 37 7/8 (962 mm) Maximum

36 1/16 (916 mm)

* See the Cutout dimensions below for self-rimming installations

13 (330mm) Max.4

NOTES:
Non-combustible surface along back wall recommended Top of finished counter 10 (254mm Min. to combustible side walls above the range (both sides)

1. 2.

18 (457mm) Min.1, 4

30 (762mm) Min.1

Utilities may be located in the lower left corner of the adjacent right cabinet (recommended). Consult local code. Self-rimming kit is included with model ER36GI. The self-rimming kit allows the trim to overlap the counter top on the sides and back. ER36G is not equipped for self-rimming installation.

Note 2

Suggested location of utilities3

Vertical to combustible surface from range grate level Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10 (254mm) from the edge of the range.
2

CABINET CUTOUT DImENSIONS


10 Min. (254mm) rear wall or to any combustibles countertop edge above counter both sides

10 Min. (254mm) to any combustibles above counter both sides

non comubustible rear wall recommended

3/4 Min. (19mm) Countertop overhang

35 1/4 (895 mm) countertop opening 36 (914 mm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets Countertop Height: Min: 35 1/2 (902 mm) Max: 37 5/8 (956 mm) Countertop Thickness: Max: 1 5/8 (41mm)

24 (610mm)

35 1/4 (895 mm) countertop opening 36 (914 mm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets Countertop Height: Min: 35 1/2 (902 mm) Max: 37 5/8 (956 mm) Countertop Thickness: Max: 1 5/8 (41mm)

24 1/8 (613mm)

Countertop overhang 2 1/8 (54 mm) Max.

Countertop overhang 2 1/8 (54mm) Max.

SELF-rImmING CUTOUT DImENSIONS CABINET DEPTH ExACTLY 24 INCHES (Er36GI ONLY)

SELF-rImmING CUTOUT DImENSIONS CABINET DEPTH GrEATEr THAN 24 INCHES (Er36GI ONLY)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.5

Document # PG05-002

Er36G, Er36GI
36 wide, Epicure Gas range

Revised 05/25/10 Page 3/3

PLANNING GUIDE

12 1/2 (318 mm)

C L

12 (305mm)
15 7/8 (403 mm) to 18 (457 mm)

3 3/4 (95 mm)


BACk OF rANGE

2 1/2 (64mm) 1 (25mm) 3 1/2 C L (89mm)


UTILITY CLEArANCE BEHIND rANGE

GAS SUPPLY PRESSURE REQUIREMENTS Gas Type Natural LP Manifold Pressure* (WC) 5 10 Min. Gas Supply Pressure (WC) 6 11 Max. Input Pressure 1/2 p.s.i. 1/2 p.s.i.

IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it). The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

15 (381 mm)

www.dacor.com

Phone: (800) 793-0093

5.6

Er30D, Er30DSr
Document # PG05-003 Revised 02/03/11 Page 1/3

Epicure ranges
46 1/4 (1175 mm) 28 13/16 (732 mm) 27 5/16 (694 mm) 26 5/16 (668 mm) 24 1/4 (616 mm)

PLANNING GUIDE

Product tolerances: 1/16 (1.6 mm) unless otherwise stated

WARNING
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

1 1/16 (27 mm)

9 (229 mm) Backguard**

6 (152 mm) 3 (76 mm) Backguard** Backguard*

NOTE: Self-rimming models are designed to allow the trim to overlap the countertop when configured to the dimensions on page 1/3. Self-rimming models are not compatible with integral backguards
45 5/8 (1159 mm) 28 3/16 (716 mm) 26 11/16 (678 mm) 25 11/16 (652 mm) 23 5/8 (600 mm) 23 1/8 (587 mm) 1 9/16 (40 mm) Front of open door Front of handle Front edge of bullnose Front panel Rear of front panel /oven door Rear of front panel to back of chassis

1 9/16 (40 mm)

1 1/16 (27 mm) to cooking surface (top of grates) from top of trim 35 3/4 (908 mm) to 37 7/8 (962 mm)

* Standard ** Optional

Width at front panel: 29 7/8 (758 mm) Finished side panel

FrEESTANDING mODELS Er30D AND Er30D-C NOTE: Models ER30D and ER30D-C are NOT designed for use with self-rimming installations or raised vents. Use model ER30DSR for self-rimming and raised vent installations.
Width at front panel: 29 7/8 (758 mm)

1 5/16 (33 mm) to cooking surface (top of grates) from bottom of trim 35 3/4 (908 mm) to 37 7/8 (962 mm)

46 1/8 (1172 mm) 28 11/16 (729 mm) 27 3/16 (691 mm) 26 3/16 (665 mm) 24 1/8 (613 mm) 23 1/8 (587 mm) 1 9/16 (40 mm)

Front of open door Front of handle Front edge of bullnose Front panel Rear of front panel /oven door Rear of front panel to back of chassis

SELF rImmING mODEL Er30DSr SIDE DImENSIONS wITH STANDArD TrIm

1 5/16 (33 mm) to cooking surface (top of grates) from bottom of trim 35 3/4 (908 mm) to 37 7/8 (962 mm)

Width at front panel: 29 7/8 (758 mm)

ELECTRIC CIRCUIT REQUIREMENTS Range Model ER30D/ER30DSR Circuit Required 240 Vac, 4-wire* 60 Hz, 30 Amp. Total Connected Load 5.6 kW (24.2 Amp.)

* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground SELF rImmING mODEL Er30DSr SIDE DImENSIONS wITH OPTIONAL rAISED vENT TrIm kIT INSTALLED (ATk30Sr) Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. The ratings above are for reference only refer to the range rating label

www.dacor.com

Phone: (800) 793-0093

5.7

Er30D, Er30DSr
Document # PG05-003 Revised 02/03/11 Page 2/3

Epicure ranges
Product tolerances: 1/16 (1.6 mm) unless otherwise stated A 4 7/8 (124 mm)

PLANNING GUIDE
GAS - ELECTRICAL ACCESS DIMENSIONS B 21 3/4 (552 mm) C 8 5/8 (219 mm) D 10 3/16 (259 mm) E 7/8* (22 mm)

* The hole size can be increased to 1 1/8 by removing the conduit bracket inside the range electrical access box.
Gas inlet Range electrical access, cover removed B D

Gas and Electrical Service


The shaded area (diagram bottom left) denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve and electrical locations. An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.

A C

7/8 (22 mm) Dia. electrical connection hole in bottom*

The installation must allow for the following:


Access to the gas shut-off valve when the unit is installed. Access to the remote circuit breaker panel/fuse box, when the range is in place. The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed. The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

BACk OF rANGE

Cabinet tolerances: +1/16, (+1.6 mm) -0


F

GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Natural Gas


13 (330 mm) Max.4

Manifold Pressure 5 Water Column 10 Water Column

Minimum Gas Supply Pressure 6 Water Column 11 Water Column

Petroleum (LP)

* Maximum input gas supply pressure for all models is 1/2 p.s.i.

18 (457 mm) Min.1, 4

Non-combustible surface along back wall recommended 30 (762 mm) G Min.1

CUT-OUT DIMENSIONS
10 (254 mm) Min. to combustible side walls above the range (both sides)

F 36 (914 mm)* 30 (762 mm)**

G 30 1/16 (916 mm)*

* Recommended ** Minimum
Note 2 36 1/2 (927 mm) Max. Suggested location of utilities 3 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10 (254 mm) from the edge of the range.
1

CABINET CUTOUT DImENSIONS mODELS Er30D AND Er3OD-C NOTE: See following page for countertop/cabinet cutout dimensions for self-rimming installations

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.8

Er30D, Er30DSr
Document # PG05-003 Revised 02/03/11 Page 3/3

Epicure ranges
Cutout tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated
Non-combustible rear wall recommeded 10 Min. (254 mm) both sides 1/4 Min. (6 mm) Countertop overhang
Non-combustible rear wall recommended 10 Min. (254 mm) both sides

PLANNING GUIDE
3/8 Min. (10 mm) Countertop overhang 2 3/8 (60 mm)

Combustible side wall above range 29 1/2 (749 mm) countertop opening 30 (762 mm) cabinet opening below countertop Cabinet face below countertop Notch countertop overhang to width of cabinets H J K

27 1/2 (699 mm) raised vent opening 29 1/2 (749 mm) countertop opening 30 (762 mm) cabinet opening below countertop Combustible side wall above range Cabinet face below countertop Notch countertop overhang to width of cabinets

H J

Countertop front

Countertop Height: Min: 35 5/8 (905 mm) Max: 37 3/8 (949 mm)

Countertop front

Countertop Height: Min: 35 5/8 (905 mm) Max: 37 1/4 (946 mm)

TOP vIEw - mODEL Er30DSr COUNTErTOP/CABINET CUTOUT DImENSIONS SELF rImmING INSTALLATION

TOP vIEw - mODEL Er30DSr COUNTErTOP/CABINET CUTOUT DImENSIONS, SELF rImmING INSTALLATION wITH rAISED vENT (ATk30Sr TrIm kIT INSTALLED) APPrOvED rAISED vENTS: Erv30 Or Prv30 H J 23 1/2 (597 mm) 20 1/2 to 23 1/2 24 (610 mm) 21 to 24 K 24 to 25 9/16 21 to 25 9/16 24 1/2 to 26 1/16 21 1/2 to 26 1/16

ER30DSR with no side panels no raised vent 3-inch side panels* and no raised vent no side panels and raised vent 3-inch side panels and raised vent

23 1/2 (597 mm) 20 1/2 (521 mm) 24 (610 mm) 21 (533 mm)

3/8 Min. (10 mm) flat countertop overhang required behind cutout Stiffener

28 3/4 (730 mm) Countertop* Cabinet face* Back of control panel Shown with optional 3-inch side panels installed** Countertop height: 35 5/8" (905 mm) Min. 37 1/4 (946 mm) Max.

3/8 Min. (10 mm) space behind raised vent chassis to clear stiffener ERV30 or PRV30 raised vent ER30DSR range: ATK30SR trim kit required for installation with raised vent

* IMPORTANT: See Countertop/Cabinet Cutout Dimensions for countertop cutout dimensions. ** IMPORTANT: If optional 3-inch side panels are not installed cabinet face must be flush with back of control panel.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.9

Er36D, Er48D
Document # PG05-004 Revised 04/21/10 Page 1/2

Epicure ranges
Product tolerances: +/- 1/16 (+/- 1.6 mm) unless otherwise stated

PLANNING GUIDE WARNING

48 (1219 mm) 30 3/4 (781 mm) 29 3/8 (746 mm) 28 1/4 (718 mm) 26 1/8 (664 mm) (229 mm)

Front of open door Front of handle Front edge of bull nose Front panel Rear of front panel/oven door

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
ELECTRIC CIRCUIT REQUIREMENTS

(51 mm) (483 mm) (387 mm)

24 (610 mm)

**

(229 mm)

Range Model ER36D

Circuit Required 240 Vac, 4-wire* 60 Hz, 30 Amp. (Min.) 40 Amp. (Recommended) 240 Vac, 4-wire* 60 Hz, 50 Amp.

Total Connected Load 6.5 kW (28 Amp.) 10.0 kW (42 Amp.)

** **

(40 mm)

1 1/16 (27 mm) to cooking surface (top of grates) from top of trim

(76 mm)

ER48D

* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
Finished side panel (940 mm)

GAS SUPPLY PRESSURE REQUIREMENTS*


(908 mm) ** Optional

Gas Type Natural Gas Propane (LP)

Manifold Pressure 5 Water Column 10 Water Column

Minimum Gas Supply Pressure 6 Water Column 11 Water Column

Width:

ER36D - 35 7/8 (911 mm) ER48D - 47 7/8 (1216 mm)

* Maximum gas supply pressure 1/2 p.s.i. for all models

GAS - ELECTRICAL ACCESS DIMENSIONS Model ER36D ER48D A 5 5/8 (142.9 mm) 3 13/16 (96.8 mm) B 18 3/8 (466.7 mm) 18 11/16 (474.7 mm) C 10 3/4 (273.0 mm) 9 3/8 (238.1 mm) D 13 11/16 (347.7 mm) 13 3/4 (349.3 mm) E* 7/8 (22.2 mm) 1 1/8 (28.6 mm)
B

Gas regulator access, cover removed

Range electrical access, cover removed

Inlet

Back of range

* The diameter on models equipped for use in Canada is (6.4mm) larger than those stated. Canadian units come from the factory pre-wired with an appliance cord. When installing an appliance cord on models that are not pre-wired, the hole size must be increased to 1 1/8 (1 3/8 for model ER48D) by removing the conduit bracket inside the range electrical access box. OVEN INTERIOR SPECIFICATIONS Model Number ER36D ER48D - Small oven ER48D - Large oven Dimensions 15" H x 29" W x 19 " D 15" H x 15" W x 19 " D 15" H x 27" W x 19 " D Volume 4.9 ft3 2.5 ft3 4.6 ft3

A C

E Electrical connection hole in bottom

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.10

Er36D, Er48D
Document # PG05-004 Revised 04/21/10 Page 2/2

Epicure ranges

PLANNING GUIDE

Cutout tolerances: +1/16 (+1.6 mm), -0 unless otherwise stated


F

Gas and Electrical Service


For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible locations. An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance. Access to the gas shut-off valve when the unit is installed. Access to the remote circuit breaker panel/fuse box, when the range is in place. The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed. The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected. CUT-OUT DIMENSIONS Range Model ER36D ER48D F 42 (1067 mm)* 36 (914 mm)** 54 (1372 mm)* 48 (1219 mm)** G 36 1/16 (916 mm)** 48 1/16 (1221 mm)** H 33 1/2 (848 mm) 43 1/2 (1102 mm)

13 (330 mm) Max.4

The installation must allow for the following:


Non-combustible surface along back wall recommended 30 (762 mm) G Min.1


10 (254 mm) Min. to combustible side walls above the range (both sides)

18 (457 mm) Min.1, 4

Note 2 36 1/2 (927 mm) Max. Suggested location of utilities 3


1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10 (254 mm) from the edge of the range.

Backsplash Minumum Countertop Height: 30 1/4 (768 mm) Maximum Countertop Height: 36 1/2 (927 mm) 3/8" (10 mm) Min. flat countertop overhang H

* Recommended **Minimum

2 13/16" (71.4 mm)

3/8 Min. (10 mm) flat countertop overhang required behind cutout

non-combustible rear wall recommended

Countertop*

Stiffener 3/8 Min. (10 mm) space behind raised vent chassis to clear stiffener

Cabinet face** Back of control panel ER36D or ER48D Range

10" (254 mm) Min. 3 to combustible side walls above the range (both sides)

ERV36-ER or ERV48-ER raised vent

Countertop height: 30 1/4" (768 mm) Min. 36 1/2 (927 mm) Max.

CUTOUT wITH OPTIONAL Erv rAISED vENT (TOP vIEw) APPROVED RAISED VENT MODELS Raised Vent Model ERV36-ER ERV48-ER For Use With Range Model ER36D ER48D

* IMPORTANT: See CUTOUT WITH OPTIONAL ERV RAISED VENT for countertop cutout dimensions. ** IMPORTANT: Cabinet face must not stick out further than back of control panel.

rAISED vENT INSTALLATION SIDE vIEw

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.11

mrES30
Document # PG05-005 Revised 11/24/10 Page 1/2

30 Inch wide millennia Electric range WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
60 (152.4 cm) long 240 Vac 4 wire conduit location

PLANNING GUIDE

All tolerances: +1/16, -0, (+1.6mm, -0) unless otherwise stated The optional full size side panels are for installation where the side of the range will not be covered by the cabinet. For the right side panel, order Dacor part number ARSR30S. Order part number ARSL30S for the left side.

Dedicated Circuit Required 240 Vac, 60 Hz., 4-wire*, 50 Amp.

Total Connected Load 12.5 kW (48.2 Amp.)

ELECTrICAL rEqUIrEmENTS The above specifications are for reference only. See the product data label for exact specifications.

36" (91.4 cm) recommended 30" (76.2 cm) min.


35 (88.9 cm)

Hood 13" (33.0 cm) max.


Non-combustible rear wall recommended

5/16 - 1 13/16 8 mm - 46 mm)

25" (63.5 cm)


Top of finished counter

Optional full size side panels (ARSL30S, ARSR30S) Removable (factory installed) 3 (7.6 cm) side panels

PrODUCT DImENSIONS - ISO vIEw


30" (76.2 cm)

18" (45.7 cm) min.*

30" (76.2 cm) 30 1/16" min.* (76.4 cm)

1 2

10" (25.4 cm) min. to combustibles side wall (both sides)

Range top

23 1/2" (59.7 cm) 25 5/16" (64.3 cm)

Rear of control Panel/oven door

Electrical locations** 1) Recommeded 2) Alternate

** 14H (35.6 cm) X 10W (25.4 cm)

* Vertical to combustible surface from cooktop surface

Door opened

Max. depth to oven door handle with door closed

Consult local code for exact location requirements

FrEESTANDING CUTOUT DImENSIONS For self-rimming cutout dimensions, see the following page.

45 1/4" (114.9 cm)

PrODUCT DImENSIONS - TOP vIEw

NOTES: 1. 2. Electrical is located in the right rear corner of the unit. Range is supplied with a 60 (1524 cm) long 240V 4-wire conduit.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.12

mrES30
Document # PG05-005 Revised 11/24/10 Page 2/2

30 Inch wide millennia Electric range


All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

PLANNING GUIDE

Backsplash

Vertical non-combustible surface rear wall

1/4" (6 mm) min. flat ledge Rear wall

25" (63.5 cm) Adjust for backsplash thickness 13/16" to 4 1/4" (2.1 - 10.8 cm) 28 11/16" (72.9 cm) 29 5/8" (75.2 cm) 11/16" (1.7 cm)

TOP vIEw - SLIDE-IN, SELF-rImmING INSTALLATION USING 3 SIDE PANELS wITH BACkGUArD rEmOvED

Vertical non-combustible surface rear wall

27 7/8" (70.8 cm)

Backsplash thicker than 3/4" (1.9 cm)

27 13/16" (70.6 cm) Adjust for backsplash over 3/4" thick from 13/16" to 3 13/16" (2.1 - 9.7 cm) 13/32" (1.0 cm) 29 1/4" (74.3 cm) 30 1/16" (76.4 cm) Countertop overhangs cabinet

1/4" (6 mm) min. flat ledge

2 13/16" (7.1 cm)

10" (25.4 cm) min. to combustible side walls above the range (both sides)

TOP vIEw - DOwNDrAFT Erv30 wITH SLIDE-IN, SELF-rImmING INSTALLATION USING 3 SIDE PANELS wITH BACkGUArD rEmOvED

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.13

Dr30D
Document # PG05 - 006 Revised 1/26/10 Page 1/2

Distinctive range
All tolerances: 1/16 (1.6 mm) unless otherwise stated.
46 3/8 (117.8 cm) 28 1/2 (72.4 cm) 26 1/2 (67.3 cm) 24 3/8 (61.9 cm) 1 1/8 (2.9 cm) Front of open door Front of knobs Front panel Rear of front panel/oven door

PLANNING GUIDE WARNING

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

9 (22.9 cm) Backguard**

6 (15.2 cm) 3 (7.6 cm) Backguard** Backguard*

1 1/8 (2.9 mm) to cooking surface (top of grates) from top of trim Width at front panel: 29 7/8 (75.9 cm) Finished side panel 35 3/4 (90.8 cm) to 37 7/8 (96.2 cm)

* Standard ** Optional

Gas inlet Range electrical access, cover removed B D

PrODUCT DImENSIONS NOTE: This range is NOT designed for self-rimming installation or installation with a raised vent. Optional Backguard and Island Trim Part Numbers Description Island trim kit (no backguard) 6 inch trim kit 9 inch trim kit Part Number ADTK30 ADB3006 ADB3009 Gas Supply Pressure Requirements* Gas Type Natural gas LP Manifold Pressure 5 water column 10 water column Minimum Gas Supply Pressure 6 water column 11 water column A 4 3/4 (12.1 cm)

A C

7/8 (2.2 cm) dia. electricalhole 7/8" to 1 1/8" dia. access connection hole in bottom*

GAS AND ELECTrICAL DImENSIONS Gas - Electrical Access Dimensions B 22 1/8 (56.2 cm) C 8 3/4 (22.2 cm) D 13 3/4 (34.9 cm)

Ranges equipped for installation in Canada: Ranges equipped for use in Canada come pre-wired with a 4-wire, 66 inch (168 cm) long, appliance cord and NEMA 14-50P plug. Do not modify the factory wiring. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician.

All other models: The conduit or appliance cord installed needs to be long enough to allow the range to be pulled out from the wall for service, while remaining connected. See next page for further details. The wiring to the range must: Include a strain relief. Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends.

* Maximum input gas supply pressure for all models is 1/2 p.s.i. The regulator inlet accommodates a 3/4 gas line. The range ships with a 1/2 to 3/4 adapter connected to the regulator. Electrical Specifications Circuit Required 240 Vac, 60 Hz., 30 Amp.* Total Connected Load 5.7 kW (23.8 Amp.)

Where local code permits, a 3 or 4 wire appliance cord may be used. It must: Be UL listed type SRD or SRDT. Be equipped with a NEMA 14-50P 4-wire plug or, where local code permits, a NEMA 10-50P 3-wire plug. www.dacor.com Phone: (800) 793-0093

* Two 120 Vac hot (L1 and L2), one neutral, one ground The ratings above are for reference only - refer to the range's product data label for exact specifications.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

5.14

Dr30D
Document # PG05 - 006 Revised 1/26/10 Page 2/2

Distinctive range
Cabinet Layout
Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood. A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. All maximum and minimum dimensions and clearances shown in the diagram below must be maintained for safe operation. The range may be installed flush to the rear wall. A non-combustible rear wall is not mandatory, but Dacor highly recommends installing a non-combustible material from the countertop level up to the vent hood or installation of a backguard. Any openings in the wall behind the appliance or in the floor underneath it must be sealed.

PLANNING GUIDE

Gas and Electrical Service


The shaded area shown below denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations. An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance.

The installation must allow for the following:


Access to the gas shut-off valve when the unit is installed. Access to the remote circuit breaker panel/fuse box when the range is in place. The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed. The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected.

Cabinet tolerances: -1/16, (+1.6mm) -0

13 (33.0 cm) Max.4

18 (45.7 cm) Min.1, 4

Non-combustible surface along back wall recommended 30 (76.2 cm) F Min.1

10 (25.4 cm) Min. to combustible side walls above the range (both sides)

Note 2 37 7/8 (96.2 cm) Max. Suggested location of utilities 3 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10 (25.4 cm) from the edge of the range.
1

Cutout Dimensions E 36 (91.4 cm)* 30 (76.2 cm)**


1

F 30 /16 (916mm)

* Recommended ** Minimum

rEqUIrED CABINET DImENSIONS

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

5.15

DUCT PLANNING GUIDE


Document # PG06 - 001 Revised 10/21/09 Page 1/1

Duct Planning Guide WARNING


All blowers, hoods and raised vents must be installed in accordance with the accompanying installation instructions. Observe all governing codes and ordinances during planning and installation. Use only duct work deemed acceptable by state, municipal and local codes and by the installation instructions. Contact your local building department for further information. To prevent combustion by-products, smoke or odors from entering the home and to improve efficiency, tape all duct joints securely. Hoods and vents may interrupt the proper flow of smoke and combustion gases from furnaces, gas water heaters and fireplaces. To avoid drawing lethal gases into the home, follow the manufacturers recommendation for these devices and consult NFPA and ASHRAE recommendations. Improper installation may result in a back draft and/or the insufficient venting of smoke and fumes. For hoods or raised vents equipped with integral blowers, DO NOT install an additional in-line or external blower to increase the length of the duct run. For hoods or raised vents not equipped with integral blowers, DO NOT install more than one in-line or external blower. Even small differences between blower air flow rates can greatly reduce the air draw. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
All duct work materials (including screws and duct tape) must be purchased separately by the customer. When planning new duct work, always look for the shortest, most direct route to the outside. Some models can accommodate venting (and/or wiring) through the back.

PLANNING GUIDE

To prevent back-drafts, a damper at the duct outlet may also be required. Make sure duct work does not interfere with floor joists or wall studs. On dual exhaust models, the two 8 exhausts may be merged into one 10 duct using a Dacor transition kit. See the installation instructions for details. With concrete slab construction, "box-in" the duct work to prevent it from collapsing when the wet concrete is poured. Also allow room for electrical conduit.

Calculating the Maximum Duct Run Length


The maximum straight duct length is determined by the type of hood or raised vent installed and type of duct used. See the hood or raised vent specifications for the maximum duct run for the desired configuration. To determine the actual length the duct work cannot exceed, subtract all of the equivalent lengths of the elbows and transitions listed below from the maximum straight duct run from the hood/raised vent specifications. After determining that your proposed duct work meets the maximum duct length requirement, proceed with the location planning. Equivalent Lengths Piece 8 90 elbow 8 45 elbow 3 X 10 to round 90 transition 3 X 10" 45 elbow 3 X 10" 90 flat elbow Roof cap Subtract 7 feet 3 feet 25 feet 7 feet 20 feet * Wall cap with damper * Piece 10 90 elbow 10 45 elbow 3 X 10 to 8/10 round transition 3 X 10" 90 elbow Subtract 5 feet 2 feet 4 feet 15 feet

General Design Requirements


* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

Duct Work Design Tips


Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45 angles are better than one 90. If multiple elbows are used, try to keep a minimum of 24 straight duct between them. Avoid S or back to back use of adjacent elbows. Keep turns as far away from the hood or raised vent exhaust as possible, and as much space between bends as possible. For best performance, use round duct instead of rectangular, especially when elbows are required. Cross-drafts or air currents caused by adjacent open windows or doors, HVAC outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.

To prevent a back draft, never decrease the duct size over the run. If existing duct work is smaller than 8 inches in diameter, remove it and replace it with 8" round, 10" inch round or 3 1/4" x 10" duct work. Do not use duct work that is smaller in cross-sectional area than these recommended types. Do not use flexible metal duct. Do not rely on tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape. Use sheet metal screws as required to support the duct weight.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

6.1

DHw Hoods
Document # PG07-001 Revised 06/24/10 Page 1/1

30, 36, 42 and 48 wide wall mount Chimney Hoods


All tolerances: 1/16 (1.6 mm), -0, unless otherwise stated

PLANNING GUIDE WARNING

15

11 3/4

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.
Chimney can accommodate up to 10 round duct work Unit can be installed to exhaust through the ceiling or through the rear wall (see diagram below).


Chimney

Min. 30 - Max. 42

5 3/4

24 3/4 16 1/4 * 12 1/2 24 30 - 36 - 42 - 48


* 18 1/4 on 48 inch model (DHW482) DHw SErIES OvErALL DImENSIONS Blower 600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control 4 12 Vac, 20 Watt halogen Baffle type, dishwasher safe 8 inch 430 stainless steel 120 Vac, 60 Hz. (see table at right for current rating) 120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground)

rEAr ExHAUST DIAGrAm IMPORTANT: The minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range. Maximum Duct Length The maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details.

Blower speeds Lights Filters Exhaust Finish Total connected load Circuit requirements

* At zero inches static pressure GENErAL SPECIFICATIONS MODEL NUMBER DHW301 Blowers Lights Filters Maximum current draw 1 2 1 3.4 Amp. DHW361 1 2 1 3.4 Amp. DHW421 1 3 1 3.6 Amp. DHW482 2 4 2 6.8 Amp.

mODEL SPECIFIC SPECIFICATIONS Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

7.1

DHI Hoods
Document # PG07-002 Revised 06/16/10 Page 1/1

36, 42, 48 and 54 wide Ceiling mount Island Hoods WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

PLANNING GUIDE
12 9/16 (31.9 cm)

All tolerances: 1/16 (1.6 mm), -0, unless otherwise stated

15 (40.0 cm)

28 (71.1 cm) to 36 (91.4 cm) 15 (39.4 cm)* 12 (31.8 cm)

DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.
Blower Blower Speeds Lights Filters Exhaust Finish Total connected load Circuit requirements 600 CFM* (1200 CFM* for units with 2 blowers) with electronic speed control 4 12 Vac, 20 Watt halogen Baffle type, dishwasher safe 8 Inch 430 stainless steel 120 Vac, 60 Hz (see table at right for current rating) 120 Vac, 15 Amp. grounded, dedicated 3-wire circuit (hot, neutral, ground) GENErAL SPECIFICATIONS

Chimney

30 (76.2 cm)

36 (91.4 cm) - 42 (106.7 cm) 48 (121.9 cm) - 54 137.2 cm)


* 18 1/4 on models DHI482 and DHI542 DHI SErIES OvErALL DImENSIONS Chimney can accommodate up to 10 round duct work

* At zero inches static pressure

Model** DHI361 DHI421 DHI482 DHI542

Blowers 1 1 2 2

Lights 4 4 4 6

Filters 1 1 2 2

Maximum Current Draw 3.8 Amp. 3.8 Amp. 6.8 Amp. 7.1 Amp.

Maximum Duct Length The maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details. IMPORTANT: The minimum installed distance from the hood to the cooking surface must be no less than 30 inches. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range.

mODEL SPECIFIC SPECIFICATIONS ** IMPORTANT ORDERING INFORMATION: Each model requires that you order a chimney assembly (Part number DHICH) in addition to the hood assembly part number.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

7.2

PHw
Document # PG07-003 Revised 01/25/11 Page 1/1

30 Inch and 36 Inch wide Glass wall mount range Hoods


Product tolerances: 1/16 (1.6 mm), -0, unless otherwise stated

PLANNING GUIDE WARNING

10 3/4 (27.3 cm) 11 7/8 (30.2 cm)

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30 inches (76.2 cm), 26 inches (66.0 cm) for an electric cooktop. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range. DO NOT install an additional in-line or external blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw of the hood.

8 dia. 203.2 cm) 26 1/8 (66.4 cm) min.* 44 (111.8 cm) max.* 25 3/8 * 19 3/4 * (64.5 cm) (50.2 cm)

5 3/4 (14.6 cm)

19 3/4 (50.2 cm)

30 (76.2 cm) or 36 (91.4 cm)**


The hood may exhaust through the ceiling on through a rear wall.

* Glass thickness of 5/16 (3 mm) not included ** Glass width must be specified at time of order. Specify glass part number: PHGXXBK where XX is the width.
OvErALL DImENSIONS

Rear of blower unit 5/16 (3 mm)

8 (20 cm)

CHImNEY mOUNTING BrACkET

Glass

GENErAL SPECIFICATIONS Blower Blower Speeds Lights Filters Exhaust Finish Power Required Circuit Required 600 CFM with electronic speed control 4 120 Vac, 50 Watt halogen (1) Mesh type, dishwasher safe (2) 8 inch 430 stainless steel with tempered glass hood 120 Vac, 60 Hz., 3.5 Amp. 120 Vac, 60 Hz., 15 Amp. 3-wire (hot, neutral, ground), grounded, dedicated circuit Min.

30 min. (76.2 cm)

Cooktop surface

ExAmPLE OF rEAr ExHAUST

INSTALLATION - SIDE vIEw

Maximum Duct Length The maximum straight duct length for the hood is 50 feet. To determine the actual maximum duct run, subtract the equivalent length of each elbow, transition and cap from 50 feet. See the Duct Planning Guide or the installation instructions for more details. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

7.3

Document # PG07-004

EH, EHr and mH wall mount range Hoods


30, 36, 42, 48, 54 wide Hoods WARNING

Revised 05/14/10 Page 1/3

PLANNING GUIDE

All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
11 7/8 (30.2 cm) A

2 (5.1 cm)

32 (81.3 cm)

13 (34.9 cm)

(1.9 cm)

9 (22.9 cm)

DImENSIONS OF OPTIONAL AHT10 TrANSITION

D E

OvErALL DImENSIONS Overall Dimensions Model EH/EHR3012 EH/EHR3612 EH/EHR4212 EH/EHR4812 MH3012 MH3612 MH4812 EH/EHR3018 EH/EHR3618 EH/EHR4218 EH/EHR4818 EH/EHR5418 MH3018 MH3618 MH4818 A 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) 41 7/8 (106.4 cm) 47 7/8 (121.6 cm) 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) 47 7/8 (121.6 cm) 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) 41 7/8 (106.4 cm) 47 7/8 (121.6 cm) 53 7/8 (136.8 cm) 29 7/8 (75.9 cm) 35 7/8 (91.1 cm) 47 7/8 (121.6 cm) 25 1/2 (64.8 cm) 26 7/8 (68.3 cm) 18 (45.7 cm) 25 1/2 (64.8 cm) 26 7/8 (68.3 cm) 12 3/8 (31.4 cm) B C 25 Min.* (63.5 cm)

Electrical access

* Height above cooking surface. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range. Minimum Cabinet Width Models EH3012, EH3018, MH3012, MH3018 EH3612, EH3618, MH3612, MH3618 EH4212, EH4218 EH4812, EH4818, MH4812, MH4818 EH5418 D 30 (76.2 cm) 36 (91.5 cm) 42 (106.7 cm) 48 (121.9 cm) 54 (137.2 cm) www.dacor.com Phone: (800) 793-0093

NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

7.4

Document # PG07-004

EH, EHr and mH wall mount range Hoods


30, 36, 42, 48, 54 wide Hoods
GENErAL SPECIFICATIONS

Revised 05/14/10 Page 2/3

PLANNING GUIDE
Weight 48 lbs. (22 kg) 53 lbs. (24 kg) 57 lbs. (26 kg) 55 lbs. (25 kg) 60 lbs. (27 kg) 70 lbs. (32 kg) 77 lbs. (35 kg) 84 lbs. (38 kg)

Weight Specifications Models EH3012, MH3012

All Models Fan speeds Filters Exhaust(s) Total connect load Lights Circuit requirement Model Specific EH48, EHR48, MH48, EH54 Lights Filters Exhaust outputs Fan* rating 3 4 2 1200 CFM EH42, EHR42 2 3 1 600 CFM EH30, EHR30, MH30, EH36, EHR36, MH36 2 2 1 600 CFM 4 Mesh type, dishwasher safe 8-inch 120 Vac, 60 Hz, 9 Amp. Max. (10.0 Amp. Max. surge) 120 Vac, 75 W halogen 120 Vac, 15 Amp. dedicated, grounded circuit

EH3018, MH3018, EH3612, MH3612 EH3618, MH3618 EH4212 EH4218 EH4812, MH4812 EH4818, MH4818 EH5418

Weight Specifications Models EHR3012 EHR3018, EHR3612 EHR3618 EHR4212 EHR4218 EHR4812 EHR4818 EHR5418 Weight 39 lbs. (18 kg) 44 lbs. (20 kg) 48 lbs. (22 kg) 46 lbs. (21 kg) 51 lbs. (23 kg) 52 lbs. (24 kg) 59 lbs. (27 kg) 66.4 lbs. (30 kg)

* Does not apply to EHR Series

Duct Size 8 round 10 round 3 X 10 rectangular

Maximum Straight Duct Run 60 feet 50 feet 50 feet

IMPORTANT: When planning the installation, you must calculate the actual length the duct work cannot exceed. To calculate actual maximum duct length, use the above specifications in combination with the Duct Planning Guide or see the hood installation instructions.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

7.5

Document # PG07-004

EH, EHr and mH wall mount range Hoods


30, 36, 42, 48, 54 wide Hoods

Revised 05/14/10 Page 3/3

PLANNING GUIDE

NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood. All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated. Single exhaust models** Standard 8 duct connection Dual exhaust models* Standard 8 duct connection Front of hood

Electrical access holes 7/8 Dia. (5.1 cm)

C L
6 1/8 (15.6 cm) 9 7/8 (25.1 cm) 19 (50.2 cm) TOP DImENSIONS 19 (50.2 cm)

C L
1 (3.8 cm) 4 (10.2 cm) 3 (7.6 cm)

C L

3 (7.6 cm) 4 (10.2 cm) (1.9 cm)

C L
9 7/8 (25.1 cm) E***

Electrical access holes 7/8 Dia. (5.1 cm)

Bottom of hood

Dual exhaust models* Standard 8 duct connection

Single exhaust models** Standard 8 duct connection

BACk DImENSIONS * Models EH48, EHR48, MH48, EH54, EHR54 ** All other models ***Rear Exhaust Placement Nominal Hood Height 12 18 Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. E 4 1/2 (11.4 cm) 6 1/8 (15.6 cm)

www.dacor.com

Phone: (800) 793-0093

7.6

IvS1, IvS2, IvSr1, IvSr2


Document # PG07 - 006 Revised 02/24/10 Page 1/1

Integrated ventilation System WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
33 1/4" (84.5 cm) 34 1/2" (87.6 cm)

PLANNING GUIDE
8" (20,3 cm) round exhausts with back draft damper Electrical access holes 6 (15.2 cm)

All tolerances: 1/16 (1.6 mm) unless otherwise stated.


8" (20,3 cm) round exhaust with back draft damper Electrical access holes 6 (15.2 cm) 21 1/4" (54.0 cm) 22 1/2" (57.2 cm)

11 1/16" (28.1 cm) 12 1/4" (31.1 cm)

IvS2/IvSr2 OvErALL DImENSIONS

6 1/2" 6 1/2" (16.5 cm) (16.5 cm)


11 1/16" (28.1 cm) 12 1/4" (31.1 cm)
C L C L C L

C L

IvS1/IvSr1 OvErALL DImENSIONS


C L

8" Exhaust
IvS2/IvSr2 ExHAUST DImENSIONS - TOP vIEw
10 inch round
C L

8" Exhaust

2" (5.1 cm)

IvS1/IvSr1 ExHAUST DImENSIONS - TOP vIEw NOTE: The Dacor IHL series integrated hood liner is designed for use with all Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces.
21" (53.3 cm) 8" (20.3 cm) 13" (33.0 cm)

ATD10 DImENSIONS - FOr USE wITH IvS2 AND IvSr2 (SOLD SEPArATELY) Model No. IVS1 IVSR1 IVS2 IVSR2 Dedicated Circuit Required 120 Vac, 60 Hz., 15 Amp. Min. grounded, dedicated circuit Maximum Duct Length Maximum 60 equivalent straight feet Total Connected Load 0.2 kW (2 Amp.) 0.2 kW (1.5 Amp.)* 0.4 kW (3 Amp.) 0.2 kW (1.5 Amp.)* Blower Configuration Internal Remote** Internal Remote** Blower Rating 600 CFM Nom. See REMP specifications 1200 CFM Nom. See REMP specifications Approximate Shipping Weight 25 lbs. 21 lbs. 38 lbs. 29 lbs.

* Does not include remote blower. ** Remote blower required. Use only Dacor REMP series remote blower *** At zero inches static pressure Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

7.7

IHL
Document # PG07-005 Revised 11/30/10 Page 1/1

Custom Hood Liners WARNING


Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

PLANNING GUIDE

The Dacor IHL series integrated hood liner is used to line the inside of custom built range hoods. It is constructed with non-combustible stainless steel and is designed for use with Dacor IVS series integrated ventilation systems. Together the IVS and IHL series products can be built into a custom hood structure to provide the required ventilation and heat resistant, easy to clean surfaces. IHL Model IHL30 IHL36 IHL42 IHL48 IVS Model IVS1 IVS1 IVS2 IVS2 IVS2

All tolerances: 1/16 (1.6 mm) unless otherwise stated.

21" (53.3 cm)

4" (10.2 cm)

IHL54

vENTILATION SYSTEm COmPATIBILITY

Mounting hole for IVS IHL mounting hole, number and locations vary with model
IHL Model IHL30 IHL36 IHL42 IHL48 IHL54 (A) Width Dimension 27 (68.6 cm) 33 (83.8 cm) 39 (99.1 cm) 45 (114.3 cm) 51 (129.5 cm)

13 7/16" (34.1 cm)

C L

Custom hood

Number Mounting Holes/Mounting Screws Required* 4 4 6 6 6 Dacor IHL series hood liner

IHL SErIES HOOD LINEr DImENSIONS * #8 mounting screws (not included) are required. Length and type must be determined according to application (mounting material). Hood liner mounting screw, number required varies with model, see table

Dacor IVS series integrated ventilation system


10" (25.4 cm)

Cap nuts/lock washers for mounting IVS (provided with IHL kit)

HEIGHT OF IHL SErIES HOOD LINEr AND IvS SErIES INTEGrATED vENTILATION SYSTEm wHEN ASSEmBLED Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.dacor.com Phone: (800) 793-0093

7.8

Document # PG08-001

Erv30, Erv36, Erv48, Prv30, Prv36, Prv46


30, 36, 46, 48 wide, Slim raised vent
2 3/16" (56 mm) 2 1/8" 5/16 (8 mm) thick stiffener (54 mm) across back 2 1/2" (64 mm) 1 15/16" (49 mm) 2 9/16" (65 mm) 3/16" (5 mm) 9/16" (14 mm) Top cap with vent down

Revised 03/29/10 Page 1/3

PLANNING GUIDE WARNING

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.
All tolerances: 1/16 (1.6 mm) unless otherwise stated

A
Vent shown in raised position

2 1/8" (54 mm) ERV top cap - side view

3/8" (10 mm)

10" (254 mm)

2 1/8" (54 mm) PRV top cap - side view

7/16" (11 mm)

B
18 5/8 (473 mm) 3 3/4" (95 mm) 1" (25 mm)

Product data label

30" 30 " (762 mm) (768 mm) to 37 " (946 mm)

6" (152 mm) Motor cover Front of unit 28" 3 prong grounded power cord

Adjustable anchor legs


DImENSIONS SIDE vIEw DImENSIONS FrONT vIEw

Model No. ERV/PRV30 ERV/PRV36 PRV46 ERV48

A 30 (762 mm) 36 (914 mm) 46 (1168 mm) 48 (1219 mm)

B 27 3/8 (695 mm) 33 3/8 848 mm) 43 3/8 (1102 mm) 43 3/8 (1102 mm)

Circuit Requirement*

NOTES: 1. 2. 3. The maximum installed height must not exceed the maximum specified countertop height of cooking appliances. Install these raised vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information. This appliance must be install in conjunction with a single Dacor approved remote or in-line blower. See following pages for approved blowers.

Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, circuit

* Includes power supply requirements for external blower

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.1

Document # PG08-001

Erv30, Erv36, Erv48, Prv30, Prv36, Prv46


30, 36, 46, 48 wide, Slim raised vent

Revised 03/29/10 Page 2/3

PLANNING GUIDE

Duct Work Design Tips


Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45 angles are better than one 90. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible. For best performance, use round duct instead of rectangular when possible, especially when elbows are required. If multiple elbows are used, try to keep a minimum of 24 of straight duct between them. Avoid S or back to back configurations of adjacent elbows. Do not use flexible metal duct.

For example, for a raised vent system using 3 1/4 X 10 rectangular duct, two (2) 3 1/4 X 10 90 elbows, a 3 1/4 X 10 rectangular to 10 round transition, and a REMP16 remote blower: From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet. The equivalent length of each 90 elbow is 15 feet. The equivalent length of 45 elbow is 2 feet. The equivalent length of the transition is 4 feet. The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet. The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet. Equivalent Number of Feet Duct Elbows and Transitions 45 elbow 8 Inch 45 elbow 10 Inch 90 elbow 8 Inch 90 elbow 10 Inch 90 3 X 10 to 8 round transition Roof cap 3 feet 2 feet 7 feet 5 feet 3 X 10 45 elbow 3 X 10 90 elbow 3 X 10 90 flat elbow 3 X 10 to 8 round transition 3 X 10 to 10 round transition Wall cap 7 feet 15 feet 20 feet 4 feet

Calculating the Maximum Duct Run Length


Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the table to the right. For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right. The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length. Raised Vent Model No. ERV/PRV30 ERV/PRV36 PRV46 ERV48 Approved Dacor Blowers* Remote blowers: REMP3 or REMP16 In-line blowers: ILHSF8 or ILHSF10

25 feet *

4 feet *

* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

*For detailed information on the remote/in-line blowers, refer to the blower installation instructions.

Duct Size Used 8 Inch 10 Inch 3 X 10

Blower Maximum Duct Straight Length REMP3 Remote Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) REMP16 Remote Blower 60 feet (18.3 meters) 70 feet (21.3 meters) 60 feet (18.3 meters) ILHSF8 In-line Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) ILHSF10 In-line Blower 60 feet (18.3 meters) 70 feet (21.3 meters) 60 feet (18.3 meters)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.2

Document # PG08-001

Erv30, Erv36, Erv48, Prv30, Prv36, Prv46


30, 36, 46, 48 wide, Slim raised vent

Revised 03/29/10 Page 3/3

PLANNING GUIDE

All tolerances: 1/16 (1.6 mm) unless otherwise stated ExHAUST OUTLET LOCATION OPTIONS SIDE vIEw FrONT vIEw

26" (660 mm)

1 1/8" (29 mm)

C (159 mm) L

6 1/4"

Front of unit Motor cover


C L

5" (127 mm)

2 X 16, connects to side or bottom exhaust on raised vent

1" (25 mm) 3 1/4 X 10 to duct work


C L

ADT2 TrANSITION (INCLUDED)

Rear Exhaust Knock Out (3 1/4 X 10) Vertical center line of rear exhaust knock out lines up with vertical Bottom Exhaust Knock Out (1 5/8 X 16) On 46 and 48 wide models, the vertical center line of bottom knock On 30 and 36 wide models, the vertical center line of bottom knock Side Exhaust Knock Outs (1 5/8 X 16)
NOTE: See the appliance planning guide page for cutout dimensions

center line of chassis

out lines up with vertical center line of chassis

out is offset 3

Blower wiring access hole in side Front of unit

Blower wiring access hole in bottom


wIrING/CONDUIT CONNECTIONS FOr rEmOTE/IN-LINE BLOwEr

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.3

Erv36-Er, Erv48-Er
Document # PG08-002 Revised 03/29/10 Page 1/3

36 and 48 wide Slim raised vent for Epicure range


Product Dimensions

1/4" (6 mm) 2 13/16" (71 mm) Top cap with vent down

PLANNING GUIDE WARNING

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

5/16 (8 mm) thick stiffener across back 2 1/2" (64 mm) 1 15/16" (49 mm)

All tolerances: +/- 1/16 (+/- 1.6 mm) unless otherwise stated

Model Number ERV36-ER ERV48-ER

A 36 (914 mm) 48 (1219 mm)

B 33 3/8 (848 mm) 43 3/8 (1102 mm)

2 9/16" (65 mm)

NOTE: See the appliance planning guide page for cutout dimensions

A
Vent shown in raised position

10" (254 mm)

B
18 5/8 (473 mm) 3 3/4" (95 mm) 1" (25 mm)

Product data label

30" 30 " (762 mm) (768 mm) to 37 " (946 mm)

6" (152 mm) Motor cover Front of unit 28" 3 prong grounded power cord

Adjustable anchor legs

NOTES: 1. 2. Install these raised vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information. This appliance must be install in conjunction with a single Dacor approved remote or in-line blower. See following pages for approved blowers.

Circuit Requirement (all models)* Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, circuit

Approved Dacor Blowers (all models)** Remote blowers: REMP3 or REMP16 In-line blowers: ILHSF8 or ILHSF10

* Includes power supply requirements for external blower. **For detailed information on the remote/in-line blowers, refer to the blower installation instructions.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.4

Erv36-Er, Erv48-Er
Document # PG08-002 Revised 03/29/10 Page 2/3

36 and 48 wide Slim raised vent for Epicure range


Duct Work Design Tips
Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45 angles are better than one 90. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible. For best performance, use round duct instead of rectangular when possible, especially when elbows are required. If multiple elbows are used, try to keep a minimum of 24 of straight duct between them. Avoid S or back to back configurations of adjacent elbows. Do not use flexible metal duct.

PLANNING GUIDE

For example, for a raised vent system using 3 1/4 X 10 rectangular duct, two (2) 3 1/4 X 10 90 elbows, a 3 1/4 X 10 rectangular to 10 round transition, and a REMP16 remote blower: From the Blower Maximum Duct Straight Length table, the maximum length without transitions and elbows is 60 feet. The equivalent length of each 90 elbow is 15 feet. The equivalent length of 45 elbow is 2 feet. The equivalent length of the transition is 4 feet. The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet. The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet. Equivalent Number of Feet Duct Elbows and Transitions 45 elbow 8 Inch 45 elbow 10 Inch 90 elbow 8 Inch 90 elbow 10 Inch 90 3 X 10 to 8 round transition Roof cap 3 feet 2 feet 7 feet 5 feet 3 X 10 45 elbow 3 X 10 90 elbow 3 X 10 90 flat elbow 3 X 10 to 8 round transition 3 X 10 to 10 round transition Wall cap 7 feet 15 feet 20 feet 4 feet

Calculating the Maximum Duct Run Length


Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the table to the right. For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right. The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length.

25 feet *

4 feet *

* The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist.

Duct Size Used 8 Inch 10 Inch 3 X 10

Blower Maximum Duct Straight Length REMP3 Remote Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) REMP16 Remote Blower 60 feet (18.3 meters) 70 feet (21.3 meters) 60 feet (18.3 meters) ILHSF8 In-line Blower 50 feet (15.2 meters) 40 feet (12.2 meters) 40 feet (12.2 meters) ILHSF10 In-line Blower 60 feet (18.3 meters) 70 feet (21.3 meters) 60 feet (18.3 meters)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.5

Erv36-Er, Erv48-Er
Document # PG08-002 Revised 03/29/10 Page 3/3

36 and 48 wide Slim raised vent for Epicure range


All tolerances: 1/16 (1.6 mm) unless otherwise stated ExHAUST OUTLET LOCATION OPTIONS SIDE vIEw FrONT vIEw

PLANNING GUIDE

Front of unit

26" (660 mm)

1 1/8" (29 mm)

C (159 mm) L

6 1/4"

5" (127 mm)

2 X 16, connects to side or bottom exhaust on raised vent

Motor cover
C L

1" (25 mm) 3 1/4 X 10 to duct work


C L

ADT2 TrANSITION (INCLUDED)

Rear Exhaust Knock Out (3 1/4 X 10) Vertical center line of rear exhaust knock out lines up with vertical Bottom Exhaust Knock Out (1 5/8 X 16) On 46 and 48 wide models, the vertical center line of bottom knock On 30 and 36 wide models, the vertical center line of bottom knock Side Exhaust Knock Outs (1 5/8 X 16)
out is offset 3 out lines up with vertical center line of chassis center line of chassis

Blower wiring access hole in side Front of unit

Blower wiring access hole in bottom


wIrING/CONDUIT CONNECTIONS FOr rEmOTE/IN-LINE BLOwEr

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.6

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 1/7

30, 36, 46 wide, raised vent


1 15/16" (49 mm) 1 13/16" 1/2 (13 mm) (46 mm) thick stiffener across back 3 1/8" (79 mm) 2" (51 mm) 2 5/16" (59 mm) 3/16" (5 mm) 9/16" (14 mm) Top cap with vent down 15/16" (24 mm)

PLANNING GUIDE WARNING

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances: +1/16, -0, (+1.6 mm, -0) unless otherwise stated

Vent shown in raised position 7 1/2" (191 mm)

7" (178 mm)

Product data label

4 5/8" (117 mm) 9 7/8 (251 mm) with CABP3 blower installed

26 3/4" 28" (711 mm) (679 mm) to 34" (864 mm)

Adjustable anchor legs Front View

Model Number RV30 RV36 RV46

A - Top Cap Width 30 (762 mm) 36 (914 mm) 46 (1168 mm)

B - Chassis Width 27 3/8 (695 mm) 33 3/8 (848 mm) 43 3/8 (1102 mm)

NOTES: 1. 2. Install these raised vents only with approved Dacor cooktops. See the planning guide for the particular appliance for proper applications and cutout information. This appliance must be install in conjunction with a single Dacor approved cabinet, remote or in-line blower. See following pages for approved blowers. For detailed information on the remote and in-line blowers, refer to the blowers installation instructions.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.7

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 2/7

30, 36, 46 wide, raised vent


Electrical Specifications General System Layout

PLANNING GUIDE

WARNING
The electric service for the raised vent should be installed only by a licensed electrician.
It is the owners responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA 70- 2002* (or latest revision) and local codes and ordinances. *A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101

The vent system consists of the raised vent itself and a single Dacor approved remote blower or internal cabinet blower. Raised Vent Model No. RV30 RV36 RV46 Approved Blowers CABP3, ILHSF8, ILHSF10, REMP3, REMP16 Duct Sizes 3 1/4 x 10, 8 round, 10 round

WARNING
Failure to install an approved blower and proper duct work will result in a back draft and/or the insufficient venting of smoke and fumes. To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooktop should be avoided. Follow the instructions and diagrams for minimum safe clearances and installation location in these instructions, the appliance installation instructions and the blower installation instructions. Failure to do so may result in a fire or safety hazard.
Install the raised vent, blower and cooktop so that they can be removed if service is required. Refer to the cooktop planning guide for the minimum cutout dimensions specific to the particular raised vent model being installed. The raised vent is equipped with adjustable anchor legs to accommodate various cabinet heights. All contact surfaces between the raised vent and any cabinets or walls must be solid and at right angles.

Electrical Requirements
Power must be supplied by a separate, grounded, single phase circuit protected by a properly sized circuit breaker or time delay fuse and rated at 120 Vac, 60 Hz, 15 Amps. The above specifications are for reference only. If the power supply requirements shown above do not agree with those listed on the product data label, use the ratings on the label. The suggested location of the junction box supplying power to the unit is to the bottom right of the unit, providing local codes permit. Install 3 conductor wiring/conduit with minimum current carrying capacity of 8 Amps to supply power to the internal cabinet blower or remote blower from the raised vent when turned on. When installing a remote or in-line blower run the wiring/ conduit parallel to the duct work and connect it to the remote blower and raised vent on the ends. There are two 7/8 access holes in the bottom of the raised vent for connecting the wiring to the blower and connecting the vent to the power supply junction box.

Cabinet blower Connection to junction box

Connection to cabinet blower

Electrical access holes in bottom

Connection to remote/in-line blower

ELECTrICAL LAYOUT

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.8

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 3/7

30, 36, 46 wide, raised vent


General System Layout (continued)
The raised vent exhaust may be configured to vent through the bottom or through one of the sides. Allow room for the exhaust duct coming out of the unit. See Planning the Duct Work for additional details. The maximum allowable duct run must be taken into consideration when determining the layout. See Planning the Duct Work for further details. Access from the front of the cabinet to the underside of the cooktop, the vent system and the electrical and gas supplies for the cooktop and vent must be provided for inspection and service. Any drawers or shelves placed below the cooktop and in front of the vent must be easy to remove for access to the cooktop, vent and utilities. For installation with gas cooktops, a 90-degree elbow must be connected to the cooktop gas inlet (see diagram below) to avoid interference with the raised vents front panel.

PLANNING GUIDE
REMP16 Series Remote Blower

3 1/4 X 10 to 10 round transition and 45 adjustable elbow Cooktop

Wall Board Backsplash Duct work between raised vent and remote blower Raised vent configured for bottom exhaust

90 Elbow

Raised Vent with internal cabinet blower mounted to front

Optional Internal Cabinet Blower Gas line with regulator attached

Floor

Wiring/conduit that supplies power to remote blower

ExAmPLE OF LAYOUT wITH rEmOTE BLOwEr, rOOF ExHAUST

Backsplash Cooktop

Internal cabinet blower


ExAmPLE OF GAS LINE rOUTING FOr GAS COOkTOP INSTALLATIONS - SIDE vIEw

Wall

Wall cap 3 1/4 x 10 90 elbow floor Duct directly through rear wall to wall cap 12 (305 mm) Min.

ExAmPLE OF LAYOUT wITH CABINET BLOwEr, ExHAUST THrOUGH wALL

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.9

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 4/7

30, 36, 46 wide, raised vent


General System Layout (continued)

PLANNING GUIDE

Cabinet back Outside wall Cooktop Raised vent Raised vent configured for bottom exhaust Wall cap on outside wall 3 1/4 X 10 to round transition Floor

Duct work Wiring/conduit from raised vent to in-line blower

Duct work ILHSF series in-line blower

ExAmPLE OF LAYOUT wITH IN-LINE BLOwEr, DUCT wOrk UNDEr FLOOr, wALL ExHAUST

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.10

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 5/7

30, 36, 46 wide, raised vent


Planning the Duct Work

PLANNING GUIDE

WARNING
To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency. For proper operation this unit must be installed with a remote blower or internal cabinet blower. Use only one of the models specified. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. DO NOT install more than one blower. Even small differences between blower air flow rates can greatly reduce the air draw by the raised vent.
You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run. Do not rely on duct tape alone to seal duct joints. Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape. Use sheet metal screws as require to support the duct weights. To prevent back-drafts, a damper at the duct outlet may also be required. Make sure duct work does not interfere with floor joists or wall studs. With concrete slab construction, box-in the duct work to prevent it from collapsing when the wet concrete is poured. Also allow room for electrical wiring from the remote blower. Cross-drafts or air currents from adjacent open windows or doors, heating/air conditioning outlets, ceiling fans and recessed ceiling lights reduce vent efficiency.

You must install one of the Dacor blower models listed below for proper operation. For models REMP3 or REMP16, see the REMP3/16 Remote Blower Installation Instructions. For model CABP3, see the instructions later in this manual. Only one blower shall be installed. BLOWER RATINGS FOR DACOR BLOWERS APPROVED FOR USE WITH RV SERIES RAISED VENTS Model Number CABP3 (cabinet) ILHSF8 (in-line) ILHSF10 (in-line) REMP3 (remote) REMP16 (remote) Rating 600 CFM* 600 CFM** 1100 CFM** 600 CFM** 1000 CFM**

* Nominal rating at zero inches static pressure, see the CABP3 Cabinet Blower Data for actual rating. ** Nominal rating at zero inches static pressure. See the blower installation instructions for actual blower rating. The raised vent can be configured to exhaust through the bottom or either side: On installations using a remote or in-line blower, the cover plate on the appropriate side or on the bottom is removed to expose the exhaust. Configure the raised vent for bottom exhaust and use an elbow to vent through the rear cabinet wall. On installations using the CABP3 blower, the blower assembly is mounted to the front of the raised vent with the exhaust pointing in the desire direction. Point the exhaust down and use an elbow to vent through the rear cabinet wall.

Duct Work Design Tips


Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45 angles are better than one 90. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible. For best performance, use round duct instead of rectangular when possible, especially when elbows are required. If multiple elbows are used, try to keep a minimum of 24 of straight duct between them. Avoid S or back to back configurations of adjacent elbows. Do not use flexible metal duct.

When planning new duct work, always look for the shortest, most direct route to the outside. Calculate the maximum duct length (see following pages) to determine if the planned duct route will work with the blower selected. On bottom exhaust installations you may cut a hole in the floor to allow the duct work to pass through. All duct work materials (including screws and duct tape) must be purchased separately by the customer.

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

www.dacor.com

Phone: (800) 793-0093

8.11

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 6/7

30, 36, 46 wide, raised vent


Planning the Duct Work (continued)
Countertop Raised vent center line

PLANNING GUIDE
Duct connection center line A

C L C L

14 3/8" (365 mm)

25 5/8" (651 mm)

1 7/8" * (48 mm)


*Back of unit lines up with back of cutout
C L

Front View

3 1/4 X 10 Duct connection

FrONT ExHAUST DImENSIONS CABP3 BLOwEr - BOTTOm ExHAUST


Bottom View

1 7/8" * (48 mm)

Side Exhaust Locations (3 1/4 X 10) Bottom Exhaust Location (3 1/4 X 10) Vertical center line of bottom exhaust lines up with vertical Internal cabinet blower mounting location
ExHAUST LOCATIONS AND DImENSIONS FOr IN-LINE/rEmOTE BLOwEr CONFIGUrATIONS (ILHSF Or rEmP SErIES BLOwErS)
center line of chassis

Countertop

Raised vent center line

B 11 5/8" (295 mm)

3 1/4 X 10 Duct connection

Duct connection center line

Cooktop

FrONT ExHAUST DImENSIONS CABP3 BLOwEr - rIGHT ExHAUST


Countertop Raised vent center line

CABP3 C L 8 3/8" (213 mm) from back of RV cutout to center line of CABP3 exhaust in any orientation (bottom, or side exahust) RV Bottom exhaust configutation with rear or bottom duct routing DUCT

11 3/4" (298 mm)

3 1/4 X 10 Duct connection

Duct connection center line

DUCT

FrONT ExHAUST DImENSIONS CABP3 BLOwEr - LEFT ExHAUST


Model RV30 RV36 RV46 A 2 (51 mm) 5 (127 mm) www.dacor.com B 6 (152 mm) 9 (229 mm) C 12 (205 mm) 9 (229 mm)

ExHAUST LOCATIONS AND SIDE DImENSIONS FOr CABP3 INTErNAL CABINET BLOwEr
Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.

Phone: (800) 793-0093

8.12

rv30, rv36, rv46


Document # PG08-003 Revised 03/29/10 Page 7/7

30, 36, 46 wide, raised vent


Calculating the Maximum Duct Run Length
Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the table to the right. For best performance, keep the duct run as short as possible and never exceed the maximums stated at the right. The maximum straight duct length for the raised vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition (see table) must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the Blower Maximum Duct Straight Length. 45 elbow 8 Inch 45 elbow 10 Inch 90 elbow 8 Inch 90 elbow 10 Inch 90 3 X 10 to 8 round transition Roof cap*

PLANNING GUIDE
Equivalent Number of Feet Duct Elbows and Transitions 3 feet 2 feet 7 feet 5 feet 3 X 10 45 elbow 3 X 10 90 elbow 3 X 10 90 flat elbow 3 X 10 to 8 round transition 3 X 10 to 10 round transition Wall cap with damper* 7 feet 15 feet 20 feet 4 feet

For example, for a raised vent system using 3 1/4 X 10 rectangular duct, two (2) 3 1/4 X 10 90 elbows, a 3 1/4 X 10 rectangular to 10 round transition with a REMP16 remote blower: From the Maximum Equivalent Straight Length table, the maximum length without transitions and elbows is 60 feet. The equivalent length of each 90 elbow is 15 feet. The equivalent length of 45 elbow is 2 feet. The equivalent length of the transition is 4 feet. The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet. The maximum amount of straight duct that can be used with a REMP16 and the above components is: 60 feet - 34 feet = 24 feet.

25 feet **

4 feet **

* For installations using the CABP3 internal cabinet blower. ** The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVAC specialist. Blower Maximum Duct Straight Length Blower Used CABP3 ILHSF8 ILHSF10 REMP3 REMP16 8 Inch Duct 50 feet (15.2 meters) 60 feet (18.3 meters) 70 feet (21.3 meters) 60 feet (18.3 meters) 70 feet (21.3 meters) 10 Inch Duct 40 feet (12.2 meters) 50 feet (15.2 meters) 80 feet (24.4 meters) 50 feet (15.2 meters) 80 feet (24.4 meters) 3 X 10 Duct 40 feet (12.2 meters) 50 feet (15.2 meters) 70 feet (21.3 meters) 50 feet (15.2 meters) 70 feet (21.3 meters)

Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.