Академический Документы
Профессиональный Документы
Культура Документы
AIR CURTAINS
2011
AIR CURTAINS
description
The new and attractive generation of Airtcnics air curtains is the
ideal solution to maintain a comfortable interior climate in commercial
outlets and public buildings that need to keep their doors open.
Airtcnics air curtains create an air stream layer over the doorway
and act as an invisible barrier which efficiently divides the inside
environment from the outside one. Therefore, it substantially reduces
heating and cooling costs up to 80%, while increasing employees and
clients comfort.
For shops, Airtcnics air curtains allow a clear view of the inside of the
shop, welcoming the client to enter easily and freely. The end result is
advantages
MAINTAINS
PROTECTS FROM
- Heating levels
- Refrigeration
- Air conditioning
- Comfort
- Clean atmosphere
The height of the installation measured from the discharge diffuser to the floor.
The width of the door.
The location of the building to determine the level of protection needed against weather conditions.
If the building has several doors in the same, different or opposite faade.
If the building has several storeys connected by escalators.
Pressure differences between the inside and outside of the building.
Door characteristics: if always open, it opens automatically, it opens manually, revolving door, etc...
Characteristics of the ventilation and air conditioning installation.
Voltage and electrical power availability.
Type of business, style and decoration of the premises.
www.aircurtains.es
WIDE RANGE
applications
Model
Kind
Minibel
Windbox
Max
Heating
E P
Common Applications
Kiosks, Fast Food and small sized shops. Restaurants and places with
usually closed door or automatic door when low pedestrian flow.
Up to 2.2 m
Up to 2.5 m
Up to 1.8 m
Eco (E only)
Optima
Recessed Optima
Windbox
Dam
Recessed Windbox
WEC (G only)
REC (G only)
Deco
Zen (M,G only)
Rund (M,G only)
Duojet (M,G only)
RotoWind (M,G only)
VariWind
Kool (A only)
Compact (M/A only)
Recommended
Installation
Height (*)
Up to 2.8 m
Up to 3.2 m
Up to 4 m
Up to 4.5 m
XL
Up to 7 m
Up to 5 m
(*) The maximum height of installation depends on the conditions of the premises. Contact us to clear up your queries or doubts.
(A) Air Only, (E) Electrical Heating, (P) Water Coil Heating LPHW.
3
MINIBEL |
Characteristics
Specifications
Power (Fans)
Voltage
Current
Speed
Airflow
Power (Heating)
Voltage
Current
Temperature Rise
Weight
Noise Level
Maximum Height (*)
MIN 600 A
112
230~1
0,52
2800
400
9
47
1,8
W
V
A
rpm
m3/h
kW
V
A
C
kg
dB(A)
m
MIN 900 A
168
230~1
0,78
2800
600
12,5
48
1,8
112
230~1
0,52
2800
400
2,5
230~1
10,4
18
10
47
1,8
168
230~1
0,78
2800
600
3,2
230~1
16,7
19
13,5
48
1,8
Dimensions
L
18
160
200
75
18
4xM6
45
MIN 600
MIN 900
L
636
936
A
600
900
B
520
820
C
566
866
Specifications
Power (Fan)
Voltage
Current
Speed
Airflow Min./Max.
Power (Heating)
Voltage (*)
Current
Temperature Rise
Weight
Noise Level
Maximum Height (**)
W
V
A
rpm
m3/h
kW
V
A
C
kg
dB(A)
m
ECO 1000 E
140/200
230V~1
0,38/0,63
1.350
950/1025
6,2
400V~3
8,7
18/17
16
65
2,2
150/230
230V~1
0,46/0,72
1.350
1225/1300
200/300
230V~1
0,57/0,88
1.350
1500/1625
7,4
400V~3
10,4
17/16
7,4
230V~1
18,5
17/16
9,3
400V~3
13
17/16
18,2
67
2,2
9,3
230V~1
23,3
17/16
22,9
69
2,2
(*) E Standard models are with electrical heating at 400V three phase. E230 Optional models at 230V single phase.
(**) Depending on installation conditions
Dimensions
300
170
30
166
17
32
30
220
62 110 48
8x9
220
18
(*)
183
L
1000
1200
1500
A
320
420
570
Specifications
Airflow
Heating
capacity
80/60C
Water
Drop
Pressure
Electrical
Heating
Capacity (*)
Electrical
Heating
Voltage
Electrical
Heating
Current
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
Weight
OPT 1000 A
OPT 1000 P
OPT 1000 E
OPT 1000 E230
m3/h
850/1350
725/1150
850/1350
850/1350
kW
8
-
Pa
5050
-
kW
4/6
3,8/5,6
V
400Vx3
230Vx1
A
5,8/8,7
16,5/24,5
W
40/87
40/87
40/87
40/87
A
0,19/0,40
0,19/0,40
0,19/0,40
0,19/0,40
dB(A)
41/50
41/50
41/50
41/50
kg
17,5
20
19,5
19,5
OPT 1500 A
OPT 1500 P
OPT 1500 E
OPT 1500 E230-6
OPT 1500 E230-9
1250/2050
1100/1750
1250/2050
1250/2050
1250/2050
12,6
-
5360
-
6/9
3,8/5,6
6/9
400Vx3
230Vx1
230Vx1
8,7/13
16,5/24,5
26/39,1
64/117
64/117
64/117
64/117
64/117
0,32/0,53
0,32/0,53
0,32/0,53
0,32/0,53
0,32/0,53
43/52
43/52
43/52
43/52
43/52
25
28,5
28,5
28,5
28,5
5,6/11,3
5,6/11,3
400Vx3
230Vx1
8,1/16,3
24,5/49,1
80/174
80/174
80/174
80/174
0,38/0,80
0,38/0,80
0,38/0,80
0,38/0,80
46/55
46/55
46/55
46/55
33
37,5
42
42
Model
OPT 2000 A
1700/2700
OPT 2000 P
1450/2300
16,7
5230
OPT 2000 E
1700/2700
OPT 2000 E230
1700/2700
Water heated pipes connection 1/2
(*) Under request other electrical heating capacities may be supplied
130
215
42,5
4/6 x M8
65
35
4/6 x M8
36
60
78
58
35
200
Control
300
40
OPT 1000
1050
940
OPT 1500
1550
1440
OPT 2000
2050
1940
970
215
300
42,5
Dimensions
Specifications
Airflow
Heating
capacity
80/60C
Water
Drop
Pressure
Electrical
Heating
Capacity (*)
Electrical
Heating
Voltage
Electrical
Heating
Current
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
Weight
RO 1000 A
RO 1000 P
RO 1000 E
RO 1000 E230
m3/h
850/1350
725/1150
850/1350
850/1350
kW
8
-
Pa
5050
-
kW
4/6
3,8/5,6
V
400Vx3
230Vx1
A
5,8/8,7
16,5/24,5
W
40/87
40/87
40/87
40/87
A
0,19/0,40
0,19/0,40
0,19/0,40
0,19/0,40
dB(A)
41/50
41/50
41/50
41/50
kg
24
26,5
26
26
RO 1500 A
RO 1500 P
RO 1500 E
RO 1500 E230-6
RO 1500 E230-9
1250/2050
1100/1750
1250/2050
1250/2050
1250/2050
12,6
-
5360
-
6/9
3,8/5,6
6/9
400Vx3
230Vx1
230Vx1
8,7/13
16,5/24,5
26/39,1
64/117
64/117
64/117
64/117
64/117
0,32/0,53
0,32/0,53
0,32/0,53
0,32/0,53
0,32/0,53
43/52
43/52
43/52
43/52
43/52
34
37,5
37,5
37,5
37,5
RO 2000 A
RO 2000 P
RO 2000 E
RO 2000 E230
1700/2700
1450/2300
1700/2700
1700/2700
16,7
-
5230
-
5,6/11,3
5,6/11,3
400Vx3
230Vx1
8,1/16,3
24,5/49,1
80/174
80/174
80/174
80/174
0,38/0,80
0,38/0,80
0,38/0,80
0,38/0,80
46/55
46/55
46/55
46/55
44,5
49
53,5
53,5
Model
Dimensions
L
40
130
31
4/6 x M8
90
Control
50
L1 (L+50)
60
41
35
200
4/6 x M8
209
445
36
446
396
259
396
209
259
31
L1
RO 1000
1000
RO 1500
1500
1050
938
1550
1438
RO 2000
2000
2050
1938
969
7
WINDBOX S,M,G |
Characteristics
Self-supporting casing construction made of galvanized plated steel, finished in structural epoxy-polyester RAL 9016 as standard. Other colours or stainless steel construction
are available on request.
Low noise centrifugal double inlet fans driven by an external rotor motor with built in
thermal protection contact. Provided by five speed selection.
Micro-perforated inlet grille with filter functions makes unnecessary an intensive filter
servicing, only has to be periodically wiped or vacuumed.
P type includes water heated coil. E type includes electrical shielded element,
three power stages with power switches included. A type is without heating, air only.
Anodised aluminium blow-out vanes, airfoil shaped, adjustable from 0 to 15
each side.
Control panel and 20m of telephonic cable with fast connectors type RJ45 (Plug & Play),
included. Optional: Interface to connect to BMS.
Specifications
Water
Drop
Pressure
80/60C
Water
Connection
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connection
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
2780
-
2x3/4
-
kW
3/6/9
-
kW
0,372
0,372
0,372
A
1,68
1,68
1,68
dB(A)
53
53
53
kg
39
41
34
Model
Airflow
Heating
capacity
80/60C
S 1000 P
S 1000 E
S 1000 A
m3/h
1250
1300
1300
kW
8,53
-
Pa
560
-
2x3/4
-
kW
6,85
-
S 1500 P
S 1500 E
S 1500 A
1875
1950
1950
12,92
-
500
-
2x3/4
-
10,80
-
4250
-
2x3/4
-
4/8/12
-
0,558
0,558
0,558
2,52
2,52
2,52
54
54
54
58
62
50
S 2000 P
S 2000 E
S 2000 A
2500
2600
2600
18,11
-
1270
-
2x3/4
-
14,46
-
3110
-
2x3/4
-
6/12/18
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
73
80
62
S 2500 P
S 2500 E
S 2500 A
3125
3250
3250
23,13
-
2530
-
2x3/4
-
18,10
-
2600
-
2x3/4
-
6/12/18
-
0,930
0,930
0,930
4,20
4,20
4,20
56
56
56
79
86
66
S 3000 P
S 3000 E
S 3000 A
3750
3900
3900
28,39
-
4440
-
2x3/4
-
21,47
-
3910
-
2x3/4
-
8/16/24
-
1,116
1,116
1,116
5,04
5,04
5,04
57
57
57
91
99
76
M 1000 P
M 1000 E
M 1000 A
1800
1850
1850
10,27
-
850
-
2x3/4
-
8,72
-
4250
-
2x3/4
-
3/6/9
-
0,510
0,510
0,510
2,22
2,22
2,22
54
54
54
39
41
34
M 1500 P
M 1500 E
M 1500 A
2700
2775
2775
16,98
-
750
-
2x3/4
-
13,86
-
6690
-
2x3/4
-
4/8/12
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
58
62
50
M 2000 P
M 2000 E
M 2000 A
3600
3700
3700
23,60
-
1950
-
2x3/4
-
18,58
-
4870
-
2x3/4
-
6/12/18
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
73
80
62
M 2500 P
M 2500 E
M 2500 A
4500
4625
4625
29,16
-
3860
-
2x3/4
-
23,18
-
4030
-
2x3/4
-
6/12/18
-
1,275
1,275
1,275
5,55
5,55
5,55
57
57
57
79
86
66
M 3000 P
M 3000 E
M 3000 A
5400
5550
5550
35,78
-
6790
2x3/4
-
28,65
-
7150
2x3/4
-
8/16/24
-
1,530
1,530
1,530
6,66
6,66
6,66
58
58
58
91
99
76
G 1000 P
G 1000 E
G 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6830
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
44
46
38
G 1500 P
G 1500 E
G 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
64
68
55
WINDBOX S,M,G |
Airflow
Heating
capacity
80/60C
Water
Drop
Pressure
80/60C
m3/h
kW
Pa
G 2000 P
G 2000 E
G 2000 A
5400
5550
5550
30,40
-
3320
-
G 2500 P
G 2500 E
G 2500 A
6300
6475
6475
36,00
-
G 3000 P
G 3000 E
G 3000 A
7200
7400
7400
42,91
-
Model
Water
Drop
Pressure
60/40C
kW
Pa
2x3/4
-
24,18
-
7860
-
5680
-
2x3/4
-
28,90
-
9530
-
2x3/4
-
34,62
-
Water
Connection
80/60C
Electrical
Heating
Capacity
3x400V-50Hz
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
kW
kW
dB(A)
kg
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
83
90
72
6000
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
87
96
76
10070
-
2x3/4
-
10,7/21,3/32
-
2,040
2,040
2,040
8,88
8,88
8,88
59
59
59
99
109
86
Water
Connection
60/40C
Weight
4/
3000
2920
1710
3000
2920
1710
3000
2920
1710
DAM |
Characteristics
Self-supporting casing construction made of galvanized plated steel, finished in
structural white RAL 9016 as standard. Other colours or stainless steel construction
are available on request.
The air inlet is located behind the front panel, replacing the traditional front air inlet
and filter grille, so eliminating the need for maintenance
Front panel with option to customise and the possibility of includying personalised
logos, signs, graphic designs, images, etc...
Low noise centrifugal double inlet fans driven by an external rotor motor with built in
thermal protection contact. Provided by five speed selection.
P type includes water heated coil. E type includes electrical shielded element,
three power stages with power switches included. A type is without heating, air
only.
Anodised aluminium blow-out vanes, airfoil shaped, adjustable from 0 to 15
each side.
Control panel and 20m of telephone cable with fast connectors type RJ45 (Plug &
Play), included. Optional: Interface to connect to BMS.
Specifications
Water
Drop
Pressure
80/60C
Water
Connection
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connection
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
2780
-
2x3/4
-
kW
3/6/9
-
kW
0,372
0,372
0,372
A
1,68
1,68
1,68
dB(A)
53
53
53
kg
43
45
38
Model
Airflow
Heating
capacity
80/60C
DAM S 1000 P
DAM S 1000 E
DAM S 1000 A
m3/h
1250
1300
1300
kW
8,53
-
Pa
560
-
2x3/4
-
kW
6,85
-
DAM S 1500 P
DAM S 1500 E
DAM S 1500 A
1875
1950
1950
12,92
-
500
-
2x3/4
-
10,80
-
4250
-
2x3/4
-
4/8/12
-
0,558
0,558
0,558
2,52
2,52
2,52
54
54
54
64
68
56
DAM S 2000 P
DAM S 2000 E
DAM S 2000 A
2500
2600
2600
18,11
-
1270
-
2x3/4
-
14,46
-
3110
-
2x3/4
-
6/12/18
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
81
88
70
DAM S 2500 P
DAM S 2500 E
DAM S 2500 A
3125
3250
3250
23,13
-
2530
-
2x3/4
-
18,10
-
2600
-
2x3/4
-
6/12/18
-
0,930
0,930
0,930
4,20
4,20
4,20
56
56
56
89
96
76
DAM S 3000 P
DAM S 3000 E
DAM S 3000 A
3750
3900
3900
28,39
-
4440
-
2x3/4
-
21,47
-
3910
-
2x3/4
-
8/16/24
-
1,116
1,116
1,116
5,04
5,04
5,04
57
57
57
103
111
88
DAM M 1000 P
DAM M 1000 E
DAM M 1000 A
1800
1850
1850
10,27
-
850
-
2x3/4
-
8,72
-
4250
-
2x3/4
-
3/6/9
-
0,510
0,510
0,510
2,22
2,22
2,22
54
54
54
43
45
38
DAM M 1500 P
DAM M 1500 E
DAM M 1500 A
2700
2775
2775
16,98
-
750
-
2x3/4
-
13,86
-
6690
-
2x3/4
-
4/8/12
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
64
68
56
DAM M 2000 P
DAM M 2000 E
DAM M 2000 A
3600
3700
3700
23,60
-
1950
-
2x3/4
-
18,58
-
4870
-
2x3/4
-
6/12/18
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
81
88
70
DAM M 2500 P
DAM M 2500 E
DAM M 2500 A
4500
4625
4625
29,16
-
3860
-
2x3/4
-
23,18
-
4030
-
2x3/4
-
6/12/18
-
1,275
1,275
1,275
5,55
5,55
5,55
57
57
57
89
96
76
DAM M 3000 P
DAM M 3000 E
DAM M 3000 A
5400
5550
5550
35,78
-
6790
2x3/4
-
28,65
-
7150
2x3/4
-
8/16/24
-
1,530
1,530
1,530
6,66
6,66
6,66
58
58
58
103
111
88
DAM G 1000 P
DAM G 1000 E
DAM G 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6830
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
48
50
42
DAM G 1500 P
DAM G 1500 E
DAM G 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
70
74
61
10
DAM |
Airflow
Heating
capacity
80/60C
Water
Drop
Pressure
80/60C
m3/h
kW
Pa
DAM G 2000 P
DAM G 2000 E
DAM G 2000 A
5400
5550
5550
30,40
-
3320
-
DAM G 2500 P
DAM G 2500 E
DAM G 2500 A
6300
6475
6475
36,00
-
DAM G 3000 P
DAM G 3000 E
DAM G 3000 A
7200
7400
7400
42,91
-
Model
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
kW
Pa
2x3/4
-
24,18
-
7860
-
5680
-
2x3/4
-
28,90
-
9530
-
2x3/4
-
34,62
-
Water
Connection
80/60C
Electrical
Heating
Capacity
3x400V-50Hz
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
kW
kW
dB(A)
kg
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
91
98
80
6000
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
97
106
86
10070
-
2x3/4
-
10,7/21,3/32
-
2,040
2,040
2,040
8,88
8,88
8,88
59
59
59
111
121
98
Water
Connection
60/40C
Weight
Dimensions
40
34
297
76
38
Control
129
33
460
L
A
100
52
4/6 x M8
20
120
580
260
580
40
70
1000
920
1500
1420
710
2000
1920
960
2500
3000
2420
2920
1210
1460
11
Characteristics
Self-supporting casing construction made of galvanized plated steel, ready to be
installed recessed in a false ceiling.
The inlet grille and blow-out nozzle are integrated in a single white frame, colour
RAL 9016. Other colours are available on request.
Low noise centrifugal double inlet fans driven by an external rotor motor with built
in thermal protection contact. Provided by five speed selection.
P type includes water heated coil. E type includes electrical shielded element,
three power stages with power switches included. A type is without heating,
air only.
Anodised aluminium blow-out vanes, airfoil shaped, pitch angle adjustable
each side.
Control panel and 20m of telephonic cable with fast connectors type RJ45
(Plug & Play), included. Optional: Interface to connect to BMS.
Specifications
Water
Drop
Pressure
80/60C
Water
Connections
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Model
Airflow
Heating
Capacity
80/60C
RS 1000 P
RS 1000 E
RS 1000 A
m3/h
1250
1300
1300
kW
8,53
-
Pa
560
-
2x3/4
-
kW
6,85
-
Pa
2780
-
2x3/4
-
kW
3/6/9
-
kW
0,372
0,372
0,372
A
1,68
1,68
1,68
dB(A)
53
53
53
kg
56
58
51
RS 1500 P
RS 1500 E
RS 1500 A
1875
1950
1950
12,92
-
500
-
2x3/4
-
10,80
-
4250
-
2x3/4
-
4/8/12
-
0,558
0,558
0,558
2,52
2,52
2,52
54
54
54
83
87
75
RS 2000 P
RS 2000 E
RS 2000 A
2500
2600
2600
18,11
-
1270
-
2x3/4
-
14,46
-
3110
-
2x3/4
-
6/12/18
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
107
114
96
RS 2500 P
RS 2500 E
RS 2500 A
3125
3250
3250
23,13
-
2530
-
2x3/4
-
18,10
-
2600
-
2x3/4
-
6/12/18
-
0,930
0,930
0,930
4,20
4,20
4,20
56
56
56
121
128
108
RS 3000 P
RS 3000 E
RS 3000 A
3750
3900
3900
28,39
-
4440
-
2x3/4
-
21,47
-
3910
-
2x3/4
-
8/16/24
-
1,116
1,116
1,116
5,04
5,04
5,04
57
57
57
135
142
122
RM 1000 P
RM 1000 E
RM 1000 A
1800
1850
1850
10,27
-
850
-
2x3/4
-
8,72
-
4250
-
2x3/4
-
3/6/9
-
0,510
0,510
0,510
2,22
2,22
2,22
54
54
54
56
58
51
RM 1500 P
RM 1500 E
RM 1500 A
2700
2775
2775
16,98
-
750
-
2x3/4
-
13,86
-
6690
-
2x3/4
-
4/8/12
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
83
87
75
RM 2000 P
RM 2000 E
RM 2000 A
3600
3700
3700
23,60
-
1950
-
2x3/4
-
18,58
-
4870
-
2x3/4
-
6/12/18
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
107
114
96
RM 2500 P
RM 2500 E
RM 2500 A
4500
4625
4625
29,16
-
3860
-
2x3/4
-
23,18
-
4030
-
2x3/4
-
6/12/18
-
1,275
1,275
1,275
5,55
5,55
5,55
57
57
57
121
128
108
RM 3000 P
RM 3000 E
RM 3000 A
5400
5550
5550
35,78
-
6790
-
2x3/4
-
28,65
-
7150
-
2x3/4
-
8/16/24
-
1,530
1,530
1,530
6,66
6,66
6,66
58
58
58
135
142
122
RG 1000 P
RG 1000 E
RG 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6830
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
61
63
55
RG 1500 P
RG 1500 E
RG 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
89
93
80
12
Water
Drop
Pressure
80/60C
m3/h
RG 2000 P 5400
RG 2000 E 5550
RG 2000 A 5550
kW
30,40
-
RG 2500 P
RG 2500 E
RG 2500 A
6300
6475
6475
RG 3000 P
RG 3000 E
RG 3000 A
7200
7400
7400
Model
Airflow
Water
Connection
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connection
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Power
Fans
230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
Pa
3320
-
2x3/4
-
kW
24,18
-
Weight
Pa
7860
-
2x3/4
-
kW
10/20/30
-
kW
1,530
1,530
1,530
A
6,66
6,66
6,66
dB(A)
57
57
57
kg
117
124
106
36,00
-
5680
-
2x3/4
-
28,90
-
6000
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
129
138
118
42,91
-
9530
-
2x3/4
-
34,62
-
10070
-
2x3/4
-
10,7/21,3/32
-
2,040
2,040
2,040
8,88
8,88
8,88
59
59
59
149
158
138
Dimensions
L
A
40
297
34
40
770
33
Control
25
38
312
76
369
6/9 x M8
20
L1 (L+50)
50
310
260
720
70
770
Recessed Windbox
Recessed Windbox
Recessed Windbox
Recessed Windbox
Recessed Windbox
1000
1500
2000
2500
3000
L1
1000
1050
920
1500
1550
1420
710
2000
2050
1920
960
2500
2550
2420
1210
3000
3050
2920
1460
13
Equipped with EC-fans of low consume that save up to 60% of the energy without
decreasing the airflow.
Self-supporting casing construction made of galvanized plated steel, finished in
structural epoxy-polyester RAL 9016 as standard.
Other colours or stainless steel construction are available on request.
Low noise centrifugal double inlet fans driven by an external rotor motor with built in
thermal protection contact. Provided by five speed selection.
Micro-perforated inlet grille with filter functions makes unnecessary an intensive filter
servicing, only has to be periodically wiped or vacuumed.
P type includes water heated coil. E type includes electrical shielded element,
three power stages with power switches included. A type is without heating, air
only.
Anodised aluminium blow-out vanes, airfoil shaped, adjustable from 0 to 15
each side.
Control panel and 20m of telephonic cable with fast connectors type RJ45 (Plug &
Play), included. Optional: Interface to connect to BMS.
Specifications
Water Drop
Pressure
80/60C
Water
Connections
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
6530
-
2x3/4
-
kW
3/6/9
kW
0,279
0,279
0,279
0,279
A
1,86
1,86
1,86
1,86
dB(A)
55
55
55
55
kg
38
44
44
46
Model
Airflow
Heating
Capacity
80/60C
WEC 1000 A
WEC 1000 P86
WEC 1000 P64
WEC 1000 E
m3/h
2700
2610
2610
2700
kW
12,85
-
Pa
1260
-
2x3/4
-
kW
11,06
-
WEC 1500 A
WEC 1500 P86
WEC 1500 P64
WEC 1500 E
3600
3480
3480
3600
18,71
-
1010
-
2x3/4
-
16,35
-
9010
-
2x3/4
-
4/8/12
0,372
0,372
0,372
0,372
2,48
2,48
2,48
2,48
56
56
56
56
55
64
64
68
WEC 2000 A
WEC 2000 P86
WEC 2000 P64
WEC 2000 E
5400
5220
5220
5400
28,52
-
2950
-
2x3/4
-
23,64
-
7520
-
2x3/4
-
6/12/18
0,558
0,558
0,558
0,558
3,72
3,72
3,72
3,72
57
57
57
57
72
83
83
90
WEC 2500 A
WEC 2500 P86
WEC 2500 P64
WEC 2500 E
6300
6090
6090
6300
35,32
-
5500
-
2x3/4
-
28,35
-
5810
-
2x3/4
-
6/12/18
0,651
0,651
0,651
0,651
4,34
4,34
4,34
4,34
58
58
58
58
76
87
87
96
WEC 3000 A
WEC 3000 P86
WEC 3000 P64
WEC 3000 E
7200
6960
6960
7200
42,06
-
9170
-
2x3/4
-
33,95
-
9740
-
2x3/4
-
8/16/24
0,744
0,744
0,744
0,744
4,96
4,96
4,96
4,96
59
59
59
59
86
97
97
106
Dimensions
4/
3000
14
2920
1710
Specifications
Water Drop
Pressure
80/60C
Water
Connections
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
6530
-
2x3/4
-
kW
3/6/9
kW
0,279
0,279
0,279
0,279
A
1,86
1,86
1,86
1,86
dB(A)
55
55
55
55
kg
55
61
61
63
Model
Airflow
Heating
Capacity
80/60C
REC 1000 A
REC 1000 P86
REC 1000 P64
REC 1000 E
m3/h
2700
2610
2610
2700
kW
12,85
-
Pa
1260
-
2x3/4
-
kW
11,06
-
REC 1500 A
REC 1500 P86
REC 1500 P64
REC 1500 E
3600
3480
3480
3600
18,71
-
1010
-
2x3/4
-
16,35
-
9010
-
2x3/4
-
4/8/12
0,372
0,372
0,372
0,372
2,48
2,48
2,48
2,48
56
56
56
56
80
89
89
93
REC 2000 A
REC 2000 P86
REC 2000 P64
REC 2000 E
5400
5220
5220
5400
28,52
-
2950
-
2x3/4
-
23,64
-
7520
-
2x3/4
-
6/12/18
0,558
0,558
0,558
0,558
3,72
3,72
3,72
3,72
57
57
57
57
106
117
117
124
REC 2500 A
REC 2500 P86
REC 2500 P64
REC 2500 E
6300
6090
6090
6300
35,32
-
5500
-
2x3/4
-
28,35
-
5810
-
2x3/4
-
6/12/18
0,651
0,651
0,651
0,651
4,34
4,34
4,34
4,34
58
58
58
58
118
129
129
138
REC 3000 A
REC 3000 P86
REC 3000 P64
REC 3000 E
7200
6960
6960
7200
42,06
-
9170
-
2x3/4
-
33,95
-
9740
-
2x3/4
-
8/16/24
0,744
0,744
0,744
0,744
4,96
4,96
4,96
4,96
59
59
59
59
138
149
149
158
Dimensions
L
A
40
297
34
40
770
33
Control
25
38
312
76
369
6/9 x M8
50
310
260
720
70
20
L1 (L+50)
L
1000
1500
2000
2500
3000
L1
1050
1550
2050
2550
3050
A
920
1420
1920
2420
2920
B
710
960
1210
1460
770
15
WINDBOX B,L,XL | High Pressure Air Curtains For Commercial And Industrial Doors
Characteristics
Specifications
Airflow
Heating
Capacity
80/60C
Water
Drop
Pressure
80/60C
Water
Connection
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
B 1000 P
B 1000 E
B 1000 A
m3/h
4000
4500
4500
kW
21,30
-
Pa
1520
-
2x1
-
kW
17,00
-
B 1500 P
B 1500 E
B 1500 A
6000
6750
6750
35,80
-
820
-
2x1
-
B 2000 P
B 2000 E
B 2000 A
8000
9000
9000
48,70
-
2010
-
B 2500 P
B 2500 E
B 2500 A
10000
11250
11250
61,20
-
B 3000 P
B 3000 E
B 3000 A
12000
13500
13500
L 1000 P
L 1000 E
L 1000 A
Water
Connection
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
2300
-
2x1
-
kW
8,1/10,9/19
-
kW
0,88
0,88
0,88
A
4
4
4
dB(A)
55
55
55
kg
64
65
51
27,10
-
3000
-
2x1
-
11,5/15,5/27
-
1,32
1,32
1,32
6
6
6
57
57
57
87
92
72
2x1
-
37,10
-
3400
-
2x1
-
16/22/38
-
1,76
1,76
1,76
8
8
8
58
58
58
111
117
92
4170
-
2x1
-
47,30
-
4400
-
2x1
-
18/30/48
-
2,20
2,20
2,20
10
10
10
60
60
60
138
146
113
72,80
-
7430
-
2x1
-
58,60
-
7860
-
2x1
-
24/36/60
-
2,64
2,64
2,64
12
12
12
62
62
62
166
173
133
5000
5500
5500
24,40
-
1980
-
2x1
-
19,60
-
3000
-
2x1
-
10/15/25
-
1,14
1,14
1,14
5,2
5,2
5,2
57
57
57
69
70
56
L 1500 P
L 1500 E
L 1500 A
7500
8250
8250
41,00
-
1050
-
2x1
-
31,20
-
3900
-
2x1
-
15/22,5/37,5
-
1,71
1,71
1,71
7,8
7,8
7,8
58
58
58
94
99
79
L 2000 P
L 2000 E
L 2000 A
10000
11000
11000
55,70
-
2660
-
2x1
-
42,50
-
4310
-
2x1
-
20/30/50
-
2,28
2,28
2,28
10,4
10,4
10,4
61
61
61
121
127
102
L 2500 P
L 2500 E
L 2500 A
12500
13750
13750
70,20
-
5440
-
2x1
-
54,60
-
5750
-
2x1
-
24/36/60
-
2,85
2,85
2,85
13
13
13
62
62
62
151
159
125
L 3000 P
L 3000 E
L 3000 A
15000
16500
16500
83,50
-
9600
-
2x1
-
67,70
-
10300
-
2x1
-
24/36/60
-
3,42
3,42
3,42
15,6
15,6
15,6
63
63
63
181
188
148
XL 1000 P
XL 1000 E
XL 1000 E37
XL 1000 A
6400
7000
7000
7000
28,02
-
2540
-
2x1
-
22,77
-
3960
-
2x1
-
10/15//25
15/22,5/37,5
-
2,20
2,20
2,20
2,20
9,56
9,56
9,56
9,56
59
59
59
59
94
95
95
81
XL 1500 P
XL 1500 E
XL 1500 E50
XL 1500 A
9600
10500
10500
10500
42,69
-
1380
-
2x1
-
36,43
-
5200
-
2x1
-
15/22,5/37,5
20/30/50
-
3,30
3,30
3,30
3,30
14,64
14,34
14,34
14,34
60
60
60
60
125
130
130
110
Model
16
WINDBOX B,L,XL | High Pressure Air Curtains For Commercial And Industrial Doors
Airflow
Heating
capacity
80/60C
Water
Drop
Pressure
80/60C
m3/h
kW
Pa
XL 2000 P
XL 2000 E
XL 2000 E60
XL 2000 A
12800
14000
14000
14000
60,87
-
3570
-
2x1
-
50,02
-
5960
-
XL 2500 P
XL 2500 E
XL 2500 E74
XL 2500 A
16000
17500
17500
17500
78,75
-
7240
-
2x1
-
63,77
-
XL 3000 P
XL 3000 E
XL 3000 E93
XL 3000 A
19200
21000
21000
21000
96,89
-
12880
-
2x1
-
79,24
-
Model
Water
Connection
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
kW
Pa
Water
Connection
60/40C
Electrical
Heating
Power
Capacity
Fans
3x400V-50Hz 230V-50Hz
Current
Fans
230V-50Hz
Noise
Level
(5 m)
Weight
kW
kW
dB(A)
kg
2x1
-
20/30/50
24/36/60
-
4,40
4,40
4,40
4,40
19,12
19,12
19,12
19,12
63
63
63
63
156
162
162
137
7700
-
2x1
-
24/36/60
27,8/46,4/74,2
-
5,50
5,50
5,50
5,50
23,90
23,90
23,90
23,90
64
64
64
64
191
199
199
166
14020
-
2x1
-
24/36/60
34,8/58,2/93
-
6,60
6,60
6,60
6,60
28,68
28,68
28,68
28,68
66
66
66
66
227
234
234
194
4/
Specifications
Model
Air
Flow
Water
Heating
Capacity
80/60C
Water
Drop
Pressure
80/60C
Water
Connections
80/60C
Water
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
Input
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
DS 1000 P
DS 1000 E
DS 1000 A
m3/h
1250
1300
1300
kW
8,53
-
Pa
560
-
2x3/4
-
kW
6,85
-
Weight
Pa
2780
-
2x3/4
-
kW
3/6/9
-
kW
0,372
0,372
0,372
A
1,68
1,68
1,68
dB(A)
53
53
53
kg
41
43
36
DS 1500 P
DS 1500 E
DS 1500 A
1875
1950
1950
12,92
-
500
-
2x3/4
-
10,80
-
4250
-
2x3/4
-
4/8/12
-
0,558
0,558
0,558
2,52
2,52
2,52
54
54
54
61
65
53
DS 2000 P
DS 2000 E
DS 2000 A
2500
2600
2600
18,11
-
1270
-
2x3/4
-
14,46
-
3110
-
2x3/4
-
6/12/18
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
77
84
66
DS 2500 P
DS 2500 E
DS 2500 A
3125
3250
3250
23,13
-
2530
-
2x3/4
-
18,10
-
2600
-
2x3/4
-
6/12/18
-
0,930
0,930
0,930
4,20
4,20
4,20
56
56
56
84
91
71
DM 1000 P
DM 1000 E
DM 1000 A
1800
1850
1850
10,27
-
850
-
2x3/4
-
8,72
-
4250
-
2x3/4
-
3/6/9
-
0,510
0,510
0,510
2,22
2,22
2,22
54
54
54
41
43
36
DM 1500 P
DM 1500 E
DM 1500 A
2700
2775
2775
16,98
-
750
-
2x3/4
-
13,86
-
6690
-
2x3/4
-
4/8/12
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
61
65
53
DM 2000 P
DM 2000 E
DM 2000 A
3600
3700
3700
23,60
-
1950
-
2x3/4
-
18,58
-
4870
-
2x3/4
-
6/12/18
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
77
84
66
DM 2500 P
DM 2500 E
DM 2500 A
4500
4625
4625
29,16
-
3860
-
2x3/4
-
23,18
-
4030
-
2x3/4
-
6/12/18
-
1,275
1,275
1,275
5,55
5,55
5,55
57
57
57
84
81
91
DG 1000 P
DG 1000 E
DG 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6830
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
46
48
40
DG 1500 P
DG 1500 E
DG 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
67
71
58
DG 2000 P
DG 2000 E
DG 2000 A
5400
5550
5550
30,40
-
3320
-
2x3/4
-
24,18
-
7860
-
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
87
94
76
DG 2500 P
DG 2500 E
DG 2500 A
6300
6475
6475
36,00
-
5680
-
2x3/4
-
28,90
-
6000
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
92
101
81
18
4/
Deco 1000
Deco 1500
Deco 2000
Deco 2500
L
1000
1500
2000
2500
L1
1096
1596
2096
2596
Details
ZEN M,G |
Characteristics
Decorative air curtain in contemporary architectural style.
Its minimalist and smart design integrates in any environment and we offer the
option to customise, meeting our clients need.
Central structure made of zinc plated steel finished in RAL 9913 black forge as
standard. Other colours available on request.
Front panels are anodized aluminium or zinc plated steel finished in RAL 9913
as standard. Options for stainless steel and gloss, matt or brushed paint finishes. Other materials are possible as wood, metal stressed finish etc...
We can include personalised logos, signs, graphic designs, etc...
Double inlet centrifugal fans with external rotor motors, with built-in thermal
protection contact, provided by five speed selection. Very low noise level.
P type includes water heated coil (80/60C or 60/40C).
E types includes electrical element with three power stages.
A type is unheated, air only.
Anodised aluminium double blow-out vanes, airfoil shaped.
Both sides adjustable discharge pitch angle.
Control panel and 20m cable with fast connectors type RJ45 (Plug & Play),
included. Optional: interface to connect to BMS, PLC, DDC...
Specifications
Airflow
Water
Heating
Capacity
80/60C
Water
Drop
Pressure
80/60C
Water
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
m3/h
kW
Pa
kW
Pa
ZEN M 1000 P
ZEN M 1000 E
ZEN M 1000 A
1875
1950
1950
10,52
-
890
-
2x3/4
-
9,04
-
4450
-
ZEN M 1500 P
ZEN M 1500 E
ZEN M 1500 A
2500
2600
2600
16,14
-
700
-
2x3/4
-
13,28
-
ZEN M 2000 P
ZEN M 2000 E
ZEN M 2000 A
3750
3900
3900
24,22
-
2020
-
2x3/4
-
ZEN M 2500 P
ZEN M 2500 E
ZEN M 2500 A
4375
4550
4550
28,66
-
3750
-
ZEN G 1000 P
ZEN G 1000 E
ZEN G 1000 A
2700
2775
2775
13,10
-
ZEN G 1500 P
ZEN G 1500 E
ZEN G 1500 A
3600
3700
3700
ZEN G 2000 P
ZEN G 2000 E
ZEN G 2000 A
ZEN G 2500 P
ZEN G 2500 E
ZEN G 2500 A
Model
20
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
Input
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
kW
kW
dB(A)
kg
2x3/4
-
3/6/9
-
0,591
0,591
0,591
2,58
2,58
2,58
54
54
54
37
40
32
6390
-
2x3/4
-
4/8/12
-
0,788
0,788
0,788
3,44
3,44
3,44
55
55
55
53
58
46
19,11
-
5140
-
2x3/4
-
6/12/18
-
1,182
1,182
1,182
5,16
5,16
5,16
56
56
56
71
77
62
2x3/4
-
22,80
-
3930
-
2x3/4
-
6/12/18
-
1,379
1,379
1,379
6,02
6,02
6,02
57
57
57
86
94
75
1300
-
2x3/4
-
11,31
-
6850
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
40
43
36
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
57
62
50
5400
5550
5550
30,40
-
3320
-
2x3/4
-
24,18
-
7860
-
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
78
85
69
6300
6475
6475
36,03
-
5700
-
2x3/4
-
28,94
-
6020
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
95
103
83
Water
Connections
80/60C
Water
Connections
60/40C
Weight
ZEN M,G |
Dimensions
40
473
291
70
16
14,5
14,5
291
4x M8
Zen 1000
Zen 1500
Zen 2000
Zen 2500
1220
1140
1115
1620
1544
1515
2120
2044
2544
2015
2620
2515
44,5
177 60
54
55
202
44,5
Custom Finishes
Painted any RAL colour or metallic
Different materials: aluminium, stainless steel AISI 304
(brushed or polished), wood, glass, PVC/PES, etc...
Logos, lights, clocks, signs, vinyls, patterns, etc...
floral
crocco/
leather
screen
vintage
wood
Examples of customized
front panels, to meet
client needs
21
RUND |
Characteristics
Specifications
Water
Drop
Pressure
80/60C
Water
Connections
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
4450
-
2x3/4
-
kW
3/6/9
-
kW
0,558
0,558
0,558
A
2,52
2,52
2,52
dB(A)
54
54
54
kg
47
49
42
Model
Airflow
Heating
Capacity
80/60C
RUND M 1000 P
RUND M 1000 E
RUND M 1000 A
m3/h
1875
1950
1950
kW
10,52
-
Pa
890
-
2x3/4
-
kW
9,04
-
RUND M 1500 P
RUND M 1500 E
RUND M 1500 A
2500
2600
2600
16,14
-
700
-
2x3/4
-
13,28
-
6390
-
2x3/4
-
4/8/12
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
71
75
63
RUND M 2000 P
RUND M 2000 E
RUND M 2000 A
3750
3900
3900
24,22
-
2020
-
2x3/4
-
19,11
-
5140
-
2x3/4
-
6/12/18
-
1,116
1,116
1,116
5,04
5,04
5,04
56
56
56
90
97
79
RUND M 2500 P
RUND M 2500 E
RUND M 2500 A
4375
4550
4550
28,66
-
3750
-
2x3/4
-
22,80
-
3930
-
2x3/4
-
6/12/18
-
1,302
1,.302
1,302
5,88
5,88
5,88
57
57
57
101
108
88
RUND M 3000 P
RUND M 3000 E
RUND M 3000 A
5000
5200
5200
34,08
-
6220
-
2x3/4
-
27,23
-
6510
-
2x3/4
-
8/16/24
-
1,488
1,488
1,488
6,72
6,72
6,72
58
58
58
112
119
99
RUND G 1000 P
RUND G 1000 E
RUND G 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6850
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
52
54
46
RUND G 1500 P
RUND G 1500 E
RUND G 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
77
81
68
RUND G 2000 P
RUND G 2000 E
RUND G 2000 A
5400
5550
5550
30,40
-
3320
-
2x3/4
-
24,18
-
7860
-
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
100
107
89
RUND G 2500 P
RUND G 2500 E
RUND G 2500 A
6300
6475
6475
36,03
-
5700
-
2x3/4
-
28,94
-
6020
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
109
118
98
RUND G 3000 P
RUND G 3000 E
RUND G 3000 A
7200
7400
7400
42,94
-
9540
-
2x3/4
-
34,63
-
10100
-
2x3/4
-
10,7/21,3/32
-
2,040
2,040
2,040
8,88
8,88
8,88
59
59
59
119
128
108
22
203,5
376
200 176
453
185
75
5x8,5
15
(*)
453
30
Vertical installation
53
4
400
60
60
220
430
430
6x
RUND 1000
RUND 1500
RUND 2000
RUND 2500
RUND 3000
L
1025
1525
2030
2530
2980
260
Horizontal installation
23
DUOJET |
Characteristics
2 outlet jets available. It reduces the energy loss as it only warms the air
of the inner jet.
Self-supporting casing construction made of galvanized plated steel, finished in
structural epoxy-polyester RAL 9016 as standard. Other colours or stainless
steel construction are available on request.
Low noise centrifugal double inlet fans driven by an external rotor motor with
built in thermal protection contact. Provided by five speed selection.
Micro-perforated inlet grille with filter functions makes unnecessary an
intensive filter servicing, only has to be periodically wiped or vacuumed
P type includes water heated coils. E type includes electrical shielded
elements, three power stages with power switches included.
Anodised aluminium blow-out vanes, airfoil shaped, adjustable from 0 to 15
each side.
Control panel and 20m of telephone cable with fast connectors type RJ45
(Plug & Play), included. Optional: Interface to connect to BMS.
Specifications
Water
Drop
Pressure
80/60C
Water
Drop
Pressure
60/40C
Pa
1820
-
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
2x3/4
-
kW
3/6/9
kW
0,56
0,56
0,56
A
2,50
2,50
2,50
dB(A)
54
54
54
kg
64
64
65
Model
Airflow
m3/h
1875
1875
1950
kW
6,70
-
Pa
380
-
2x3/4
-
kW
5,60
-
3125
3125
3250
11,20
-
420
-
2x3/4
-
9,50
-
3400
-
2x3/4
-
4/8/12
0,93
0,93
0,93
4,20
4,20
4,20
56
56
56
87
87
92
4375
4375
4550
16,40
-
1090
-
2x3/4
-
13,15
-
2640
-
2x3/4
-
6/12/18
1,30
1,30
1,30
5,85
5,85
5,85
57
57
57
111
111
117
5625
5625
5850
21,60
-
2230
-
2x3/4
-
16,80
-
2270
-
2x3/4
-
6/12/18
1,49
1,49
1,49
6.82
6.82
6,82
58
58
58
138
138
146
2700
2700
2775
8,50
-
620
-
2x3/4
-
7,20
-
3040
-
2x3/4
-
3/6/9
0,76
0,76
0,76
3,33
3,33
3,33
55
55
55
69
69
70
4500
4500
4625
14,20
-
620
-
2x3/4
-
12,30
-
5360
-
2x3/4
-
4/8/12
1,27
1,27
1,27
5,55
5,55
5,55
57
57
57
94
94
99
6300
6300
6475
20,75
-
1660
-
2x3/4
-
17,00
-
4140
-
2x3/4
-
6/12/18
1,79
1,79
1,79
7,77
7,77
7,77
58
58
58
121
121
127
8100
8100
8325
27,30
-
3410
-
2x3/4
-
21,70
-
3590
-
2x3/4
-
6/12/18
2,28
2,28
2,28
9,99
9,99
9,99
59
59
59
151
151
159
24
Water
Connections
80/60C
Heating
Capacity
60/40C
Heating
Capacity
80/60C
Water
Connections
60/40C
DUOJET |
40
318
38
76
34
Control
128
33
480
51
4/
450
480
90
1000
920
B
-
1500
1420
710
2000
1920
960
2500
2420
1210
15
40
B
125
318
Control
33
480
38
34
6/9 x M10
20
450
51
558
76
450
15
450
450
480
90
1000
920
B
-
1500
1420
710
2000
1920
960
2500
2420
1210
450
25
Specifications
Water
Drop
Pressure
80/60C
Water
Connections
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Model
Airflow
Heating
Capacity
80/60C
ROTO M 1000 P
ROTO M 1000 E
ROTO M 1000 A
m3/h
1875
1950
1950
kW
10,52
-
Pa
890
-
2x3/4
-
kW
9,04
-
Pa
4450
-
2x3/4
-
kW
3/6/9
-
kW
0,558
0,558
0,558
A
2,52
2,52
2,52
dB(A)
54
54
54
kg
-
ROTO M 1500 P
ROTO M 1500 E
ROTO M 1500 A
2500
2600
2600
16,14
-
700
-
2x3/4
-
13,28
-
6390
-
2x3/4
-
4/8/12
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
ROTO M 2000 P
ROTO M 2000 E
ROTO M 2000 A
3750
3900
3900
24,22
-
2020
-
2x3/4
-
19,11
-
5140
-
2x3/4
-
6/12/18
-
1,116
1,116
1,116
5,04
5,04
5,04
56
56
56
ROTO M 2500 P
ROTO M 2500 E
ROTO M 2500 A
4375
4550
4550
28,66
-
3750
-
2x3/4
-
22,80
-
3930
-
2x3/4
-
6/12/18
-
1,302
1,302
1,302
5,88
5,88
5,88
57
57
57
ROTO G 1000 P
ROTO G 1000 E
ROTO G 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6850
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
ROTO G 1500 P
ROTO G 1500 E
ROTO G 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
ROTO G 2000 P
ROTO G 2000 E
ROTO G 2000 A
5400
5550
5550
30,40
-
3320
-
2x3/4
-
24,18
-
7860
-
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
ROTO G 2500 P
ROTO G 2500 E
ROTO G 2500 A
6300
6475
6475
36,03
-
5700
-
2x3/4
-
28,94
-
6020
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
26
On top mounting
285
285
360
360
L
4/6xM8
6x12
DI
4/6xM8
DI
6x12
Fixation system
1.
2.
3.
27
Specifications
Water
Drop
Pressure
80/60C
Water
Connections
80/60C
Heating
Capacity
60/40C
Water
Drop
Pressure
60/40C
Water
Connections
60/40C
Electrical
Heating
Capacity
3x400V-50Hz
Fans
Power
230V-50Hz
Fans
Current
230V-50Hz
Noise
Level
(5 m)
Weight
Pa
2780
-
2x3/4
-
kW
3/6/9
-
kW
0,372
0,372
0,372
A
1,68
1,68
1,68
dB(A)
53
53
53
kg
39
41
34
Model
Airflow
Heating
Capacity
80/60C
VARI S 1000 P
VARI S 1000 E
VARI S 1000 A
m3/h
1250
1300
1300
kW
8,53
-
Pa
560
-
2x3/4
-
kW
6,85
-
VARI S 1500 P
VARI S 1500 E
VARI S 1500 A
1875
1950
1950
12,92
-
500
-
2x3/4
-
10,80
-
4250
-
2x3/4
-
4/8/12
-
0,558
0,558
0,558
2,52
2,52
2,52
54
54
54
58
62
50
VARI S 2000 P
VARI S 2000 E
VARI S 2000 A
2500
2600
2600
18,11
-
1270
-
2x3/4
-
14,46
-
3110
-
2x3/4
-
6/12/18
-
0,744
0,744
0,744
3,36
3,36
3,36
55
55
55
73
80
62
VARI S 2500 P
VARI S 2500 E
VARI S 2500 A
3125
3250
3250
23,13
-
2530
-
2x3/4
-
18,10
-
2600
-
2x3/4
-
6/12/18
-
0,930
0,930
0,930
4,20
4,20
4,20
56
56
56
79
86
66
VARI M 1000 P
VARI M 1000 E
VARI M 1000 A
1800
1850
1850
10,27
-
850
-
2x3/4
-
8,72
-
4250
-
2x3/4
-
3/6/9
-
0,510
0,510
0,510
2,22
2,22
2,22
54
54
54
39
41
34
VARI M 1500 P
VARI M 1500 E
VARI M 1500 A
2700
2775
2775
16,98
-
750
-
2x3/4
-
13,86
-
6690
-
2x3/4
-
4/8/12
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
58
62
50
VARI M 2000 P
VARI M 2000 E
VARI M 2000 A
3600
3700
3700
23,60
-
1950
-
2x3/4
-
18,58
-
4870
-
2x3/4
-
6/12/18
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
73
80
62
VARI M 2500 P
VARI M 2500 E
VARI M 2500 A
4500
4625
4625
29,16
-
3860
-
2x3/4
-
23,18
-
4030
-
2x3/4
-
6/12/18
-
1,275
1,275
1,275
5,55
5,55
5,55
57
57
57
79
86
66
VARI G 1000 P
VARI G 1000 E
VARI G 1000 A
2700
2775
2775
13,10
-
1300
-
2x3/4
-
11,31
-
6830
-
2x3/4
-
5/10/15
-
0,765
0,765
0,765
3,33
3,33
3,33
55
55
55
44
46
38
VARI G 1500 P
VARI G 1500 E
VARI G 1500 A
3600
3700
3700
20,30
-
1050
-
2x3/4
-
16,72
-
9410
-
2x3/4
-
7,5/15/22,5
-
1,020
1,020
1,020
4,44
4,44
4,44
56
56
56
64
68
55
VARI G 2000 P
VARI G 2000 E
VARI G 2000 A
5400
5550
5550
30,40
-
3320
-
2x3/4
-
24,18
-
7860
-
2x3/4
-
10/20/30
-
1,530
1,530
1,530
6,66
6,66
6,66
57
57
57
83
90
72
VARI G 2500 P
VARI G 2500 E
VARI G 2500 A
6300
6475
6475
36,00
-
5680
-
2x3/4
-
28,90
-
6000
-
2x3/4
-
10,7/21,3/32
-
1,785
1,785
1,785
7,77
7,77
7,77
58
58
58
87
96
76
28
Variwind 1000
Variwind 1500
Variwind 2000
Variwind 2500
Standard L
1045
1545
2050
2550
Customised L
1045-1544
1545-2049
2050-2549
2550-3000
4/
4/
4/
KOOL |
Characteristics
Specifications
Model
Fans power
Input
230V-50Hz
kW
0,372
0,558
0,744
0,930
1,116
Fans
Current
230V-50Hz
A
1,68
2,52
3,36
4,20
5,04
Noise level
(5 m)
dB(A)
53
54
55
56
57
Weight
kg
29
44
53
58
63
Without heating
Air only
KS 1000 A
KS 1500 A
KS 2000 A
KS 2500 A
KS 3000 A
Airflow
m3/h
1300
1950
2600
3250
3900
KM 1000 A
KM 1500 A
KM 2000 A
KM 2500 A
KM 3000 A
1850
2775
3700
4625
5550
0,510
0,765
1,020
1,275
1,530
2,22
3,33
4,44
5,55
6,66
54
55
56
57
58
29
44
53
58
63
KG 1000 A
KG 1500 A
KG 2000 A
KG 2500 A
KG 3000 A
2775
3700
5550
6475
7400
0,765
1,020
1,530
1,785
2,040
3,33
4,44
6,66
7,77
8,88
55
56
57
58
59
33
49
63
68
73
49
Dimensions
340
30
1500
1420
710
2000
1920
960
2500
3000
2420
2920
1210
1460
40
66
A
920
B
A
L
4/6 x M8
Control
B
40
257
L
1000
193
260
B
40
B
A
L
40
340
30
17
60
18
260
4/6 x M8
Specifications
Model
COM 1000
COM 1500
COM 2000
COM 2500
Airflow
m3/h
1860
2480
3720
4340
Without heating
Air only
-
Fans power
230V-50Hz
kW
0,62
0,83
1,24
1,45
Fans current
230V-50Hz
A
3,30
4,40
6,60
7,70
Noise level
(5 m)
dB(A)
52
53
54
55
Weight
kg
21
32
43
55
Dimensions
4/
4/
COM 1000
COM 1500
COM 2000
COM 2500
L
1000
1500
2000
2500
31
MAX |
Characteristics
Heavy casing made of double chamber aluminium profiles and hot galvanized
plated steel panels, finished white RAL 9016 as standard. Other colours are
available on request.
Vertical or horizontal installation on indurstrial door.
Axial fans driven by an external rotor motor with built-in thermal contact
protection. Provided with five speed selection. Extremely low noise.
Maintenance free.
P type includes water heated coil. E type includes electrical shielded
element, three power stages. A type is without heating, air only.
Anodised aluminium blow-out vanes, airfoil shaped, adjustable from 0 to 15
each side.
Control panel and 20m of telephonic cable with fast connectors type RJ45
(Plug & Play), included. Optional: Interface to connect to BMS.
Specifications
Model
Airflow
Water
heating
capacity
80/60C
Water
drop
pressure
80/60C
Water
connections
80/60C
Water
heating
capacity
60/40C
Water
drop
pressure
60/40C
Water
connections
60/40C
Electrical
heating
capacity
3x400V-50Hz
Fans
power
230V-50Hz
Fans
current
230V-50Hz
Noise
level
(5 m)
Weight
MAX 2 P
MAX 2 E
MAX 2 A
m3/h
7000
8000
8000
kW
40,70
-
Pa
330
-
2x1
-
kW
34,20
-
Pa
7810
-
2x1
-
kW
13,7/22,9/36,6
-
kW
0,68
0,68
0,68
A
2,96
2,96
2,96
dB(A)
59
59
59
kg
75
74
59
MAX 3 P
MAX 3 E
MAX 3 A
10500
12000
12000
61,00
-
1280
-
2x1
-
53,10
-
11400
-
2x1
-
20,7/34,7/55,4
-
1,02
1,02
1,02
4,44
4,44
4,44
61
61
61
102
100
79
MAX 4 P
MAX 4 E
MAX 4 A
14000
16000
16000
85,90
-
3300
-
2x1
-
74,20
-
9230
-
2x1
-
27,8/46,4/74,2
-
1,36
1,36
1,36
5,92
5,92
5,92
62
62
62
135
133
103
MAX 5 P
MAX 5 E
MAX 5 A
17500
20000
20000
108,00
-
6640
-
2x1
-
93,00
-
18430
-
2x1
-
34,8/58,2/93
-
1,70
1,70
1,70
7,40
7,40
7,40
64
64
64
162
159
124
MAX 6 P
MAX 6 E
MAX 6 A
21000
24000
24000
127,00
-
11270
-
2x1
-
104
-
3610
-
2x1
-
consult
-
2,04
2,04
2,04
8,88
8,88
8,88
65
65
65
189
186
151
Dimensions
MAX 2
MAX 3
MAX 4
MAX 5
MAX 6
32
L
1234
1811
2388
2965
3542
2 Speed Range
Suitable for Optima and Recessed Optima air curtains.
CW-2AO-NE
Only air and water
control panel
2 fan speed
CE-2AO-NE
Electrical control panel
2 fan speed and
2 heating stages
5 Speed Range
Suitable for Windbox, Recessed Windbox, Deco, Rund, Rotowind, Variwind, Compact and Max air curtains.
CA-5AW-NE
Only air control panel
5 fan speed
CW-5AW-NE
Water control panel
5 fan speed and
electro-valve switch
CE-5AW-NE
Electrical control panel
5 fan speed and
3 heating stages
D-805 Hand/Auto
Water control panel (Optional)
Manual and automatic operating.
Auxiliary functions with anti-freeze
sensor, door contact and ambience thermostat.
TD
Digital Thermostat
Modifies heat stages and fan
speed depending on temperature
and selected program. Only for
electrical units.
Interface
Allows the connection to a centralized management system like
BMS...
CT Total Control
Suitable for all models from Optima
to Max (except Minibel and Eco).
Auxiliary devices: anti-freeze sensor,
door contact, thermostat, etc
Time programmer: 3 ON/OFF for
each different day of the week.
Digital display with hour, fan speed,
heating stage, temperature
Multilanguage display 9 languages.
Manual or automatic functioning with
programmable behaviours.
IR Control
Infrared remote control.
Available for all models except
Minibel.
33
AIR CURTAINS
Multiple air curtain connection
Accessories
Feet, wall supports, vibration dampers
Thermostatic valve, solenoid valve, anti-freeze sensor, door contact, ambient thermostat
Water temperature
Water coil
80/60
Water coil
60/40
34
18C
20C
1,58
1,53
1,46
1,35
1,27
1,22
80/60C
1,11
1,04
1,00
70/50C
0,89
0,82
0,78
60/40C
0,66
0,59
0,54
55/35C
0,54
0,47
0,42
100/80C
2,86
2,71
2,62
90/70C
2,45
2,30
2,21
80/60C
2,03
1,89
1,81
70/50C
1,61
1,48
1,40
60/40C
1,21
1,08
1,00
55/35C
1,01
0,88
0,79
100/80C
90/70C
The technical data tables give the nominal heat capacity for warm
water coils supplied with water at 80/60C and 60/40C with the
air inlet temperature at 20C.
These tables supply the corresponding factors for calculating the
heat capacity with different air and water inlet temperatures.
Nominal
Power
(23,6 kW)
Coefficient
(1,35)
31,86 kW
GALLERY
Optima
Installation in a
shopping center
Recessed Windbox
Designed to be installed
in a false ceiling
ZEN
Windbox
Free hanging
in a big mall
Rotowind
Rund
Cylindrical design
with tailor-made goalpost
Rund
Max
Multiple towers on
large industrial doors
35