Test Certification :
The following test procedures were successfully performed on the Micro VBB:
The Vibration test was performed according with IS9000 procedure for operation conditions. To approximate
rigid mounting Micro VBB clamped on a Aluminum plate and subjected to the following test condition.
A Sine wave with Algorithm Sweep from 10- 500 Hz +/- 5mm with 5g Acceleration without resonance.
Duration of test was Three hours. One hour per axis.
Humidity Test : Performed for 90 % Humidity at 55 C for a Single Cycle of 24 Hours. After the test Micro
VBB found no abnormalities.
High Temperature Test : Micro VBB undergone High temperature test at +85 C +/- 2 C for 4 hours and it
was found functional when it comes to 55 C +/- 2C. It has not shown any abnormalities after the test
conditions were removed.
Storage Temperature: +85 C,Operating Temperature:+55 C.
Low Temperature Test : Low temperature test were conducted at –40 C for four hours and it was found
functional when the temperature comes down to –10 C.
Storage Temperature:-40 C,Operating Temperature:-10 C.
Electro Static Discharge Test: The Micro VBB with stand Electro Static Discharge up to 1500 V with 6
Events both positive and negative pulses applied to Micro VBB. This is according to standard CI-280A, B of
Ford Motor Company.
Component Immunity Power Cycling: According to the Standard CI – 230 A, CI – 230 B, CI – 230 C in
the standard test environment Micro VBB was tested and it was functioning properly.
DC Voltage Stress: Micro VBB withstand the negative voltage Stress of –14 V for 60 Sec accordance to
Standard CI-270 A. It also underwent positive voltage stress of 19 V for 60 minutes. Standard CI-270B. In
Accordance to CI-270C standard Micro VBB withstand up to 24 V DC for 60 Sec.
http://www.microvbb.net/home/vbbperformance.asp 11/20/2007
MicroVBB : Performance Sheet Page 2 of 2
Conducted Immunity Inductive Switching Transients: Micro VBB is tested for Ford Inductive Switching CI-
220B –300V at 0.5 Sec interval and the Total test events was 120.
IS0 7637 Modified test pulse –2 : +150V at 0.5 Sec intervals for 120 Events
IS0 7637 Test pulse 3A: -150V at total time duration of One Minute with pulse of 10 mSec duration at
interval of 90 mSec between the consecutive pulses.
ISO 7637 Test Pulse 3B: 100V Pulse of 10mSec duration with 90 mSec intervals for total time duration of 1
minute. In these conditions Micro VBB gave Positive results
ERTL Certificate For MicroVBB Test Result On High Temperature And Low Temperature. TOP