Академический Документы
Профессиональный Документы
Культура Документы
3 Phase
LV Induction Motors
About us
H
avells India Ltd, a US$1.3bn company, and one of the largest & Indias fastest growing electrical and power distribution
equipment company, manufacturing products ranging from Building Circuit Protection, Industrial & Domestic Switchgear,
Cables, Energy Meters, Fans, CFL Lamps, Luminaires for Domestic, Commercial & Industrial application and Modular
Switches.
Havells owns some of the prestigious global brands like Crabtree, Sylvania, Concord, Lumiance, Claude, Linolite, SLI Lighting
& Zenith.
With 91 branches / representative offices and over 8000 professionals spread over 50 countries across the globe, the group
has achieved rapid success in the past few years. Its 20 state of the art manufacturing plants spread over India, Europe, Latin
America & Africa churns out globally acclaimed products.
To add to the existing state-of-the-art manufacturing plants, Havells has now started a world class Motor Plant at Neemrana
(Rajasthan). It is one of the largest LV Motor Plant in Asia spread over 42 acres and is manufacturing energy efficient motors ranging
from 0.12HP to 470HP.
The plant has a capacity of manufacturing over 20000 motors per month. The state-of-the art plant and machinery has been
imported from AEG Spain.
Some of the salient features of the plant and the product are :
Havells is committed to manufacturing excellence and providing world class quality products at affordable prices. Havells offers
a complete solution which is not only safe and reliable but also saves energy. We continue the same tradition with our motors.
MHLP 1A
R e v i s i o n - 4
Motor Type
Efficiency
Voltage Variation
Frequency Variation
50 Hz 5%
Combined Variation
Enclosure
TEFC
Mounting
Foot, Face, Flange, Foot cum Flange & Foot cum face
Frame Dimensions
Altitude
Upto 1000M
Relative Humidity
Upto 100%
Degree of Protection
Class of Insulation
Class F
50C / 70C
Duty / Rating
Top
Direction of Rotation
Bi-directional
Grease Type
Cooling
Paint
RAL 9005
Material specificationS
Motor parts
Frame size
Material
Stator frame
56 - 160
90 - 355
Aluminium alloy
Cast iron
Endshield
56 - 112
90 - 355
Aluminium alloy
Cast iron
Flanged endshield
56 - 112
90 - 355
Aluminium alloy
Cast iron
Fan cover
56 - 71
63 - 355
Fan
56 - 355
Terminal box
56 - 71
63 - 160
160- 355
MHLP 1A
R e v i s i o n - 6
Frame
MH56ZAA2
MH56ZBA2
MH63ZAA2
MH63ZBA2
MH71ZAA2
MH71ZBA2
MH80ZAA2
MH80ZBA2
MH90SAA2
MH90LCA2
MH100LAA2
MH100LBA2
MH132SYA2
MH132SZA2
MH160MTA2
MH160MVA2
MH160MXA2
MH160LXA2
MH180MXG2
MH200LLG2
MH200LNG2
MH225MN2
MH250MN2
MH280ST2
MH280MT2
Cat. Ref.
MHHXTAS20X09
MHHXTAS20X12
MHHXTBS20X18
MHHXTBS20X25
MHHXTCS20X37
MHHXTCS20X55
MHHXTDS20X75
MHHXTDS201X1
MHCXTES201X5
MHCXTFS202X2
MHCXTGS20003
MHCXTGS203X7
MHCXTIS205X5
MHCXTIS207X5
MHCXTKS209X3
MHCXTKS20011
MHCXTKS20015
MHCXTLS2018X5
MHCXTMS20022
MHCXTOS20030
MHCXTOS20037
MHCXTQS20045
MHCXTRS20055
MHCXTSS20075
MHCXTTS20090
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and
are listed in EFF1 pricelist
Frame
MH63ZCA2
MH71ZCA2
MH80ZCA2
MH90SBA2
MH90LDA2
MH112MAA2
MH100LCA2
MH 112MBA2
MH132MZA2
MH132MRA2
MH132MTA2
MH160LRA2
MH180MRG2
Cat. Ref.
MHHXTBS20X37
MHHXTCS20X75
MHHXTDS201X5
MHCXTES201X8
MHCXTFS20003
MHCXTHS203X7
MHCXTGS205X5
MHCXTHS205X5
MHCXTJS209X3
MHCXTJS20011
MHCXTJS20015
MHCXTLS20022
MHCXTMS20030
MHLP 1A
R e v i s i o n - 6
Kw
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
Frame
MH56ZAA4
MH56ZBA4
MH63ZAA4
MH63ZBA4
MH71ZAA4
MH71ZBA4
MH80ZAA4
MH80ZBA4
MH90SAA4
MH90LBA4
MH100LAA4
MH112MAA4
MH132SZA4
MH132MZA4
MH160MYA4
MH160MXA4
MH160LXA4
MH180MXG4
MH180LXG4
MH200LNG4
MH225SN4
MH225MN4
MH250MN4
MH280ST4
MH280MT4
Cat. Ref.
MHHXTAS40X06
MHHXTAS40X09
MHHXTBS40X12
MHHXTBS40X18
MHHXTCS40X25
MHHXTCS40X37
MHHXTDS40X55
MHHXTDS40X75
MHCXTES401X1
MHCXTFS401X5
MHCXTGS402X2
MHCXTHS403X7
MHCXTIS405X5
MHCXTJS407X5
MHCXTKS409X3
MHCXTKS40011
MHCXTLS40015
MHCXTMS4018X5
MHCXTNS40022
MHCXTOS40030
MHCXTPS40037
MHCXTQS40045
MHCXTRS40055
MHCXTSS40075
MHCXTTS40090
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Frame
MH63ZCA4
MH71ZCA4
MH80ZCA4
MH90LCA4
MH90LDA4
MH100LBA4
MH100LCA4
MH112MBA4
MH132MRA4
MH132MTA4
MH180LRG4
MH200LFG4
MH250MK4
Cat. Ref.
MHHXTBS40X25
MHHXTCS40X55
MHHXTDS401X1
MHCXTFS401X8
MHCXTFS402X2
MHCXTGS40003
MHCXTGS403X7
MHCXTHS405X5
MHCXTJS409X3
MHCXTJS40011
MHCXTNS40030
MHCXTOS40037
MHCXTRS40075
MHLP 1A
R e v i s i o n - 6
Frame
MH71ZAA6
MH80ZAA6
MH80ZBA6
MH90SAA6
MH90LBA6
MH100LAA6
MH112MAA6
MH132SYA6
MH132MZA6
MH160MZA6
MH160LYA6
MH160LZA6
MH180LZG6
MH200LPG6
MH200LRG6
MH225MP6
MH250MP6
MH280SV6
MH280MV6
Cat. Ref.
MHHXTCS60X18
MHHXTDS60X37
MHHXTDS60X55
MHCXTES60X75
MHCXTFS601X1
MHCXTGS601X5
MHCXTHS602X2
MHCXTIS603X7
MHCXTJS605X5
MHCXTKS607X5
MHCXTLS609X3
MHCXTLS60011
MHCXTNS60015
MHCXTOS6018X5
MHCXTOS60022
MHCXTQS60030
MHCXTRS60037
MHCXTSS60045
MHCXTTS60055
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Frame
MH71ZBA6
MH100LBA6
MH112MBA6
MH132SZA6
MH132MTA6
Cat. Ref.
MHHXTCS60X25
MHCXTGS601X8
MHCXTHS60003
MHCXTIS60003
MHCXTJS607X5
MHLP 1A
R e v i s i o n - 6
Kw
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
Frame
MH71ZAA8
MH80ZAA8
MH90SAA8
MH90LBA8
MH100LAA8
MH100LBA8
MH112MAA8
MH132SZA8
MH160MYA8
MH160MZA8
MH160LZA8
MH180LYG8
MH180LZG8
MH200LRG8
MH225SP8
MH225MP8
MH250MP8
MH280SV8
MH280MV8
Cat. Ref.
MHHXTCS80X12
MHHXTDS80X25
MHCXTES80X37
MHCXTFS80X55
MHCXTFS80X75
MHCXTGS801X1
MHCXTHS801X5
MHCXTIS802X2
MHCXTKS803X7
MHCXTKS805X5
MHCXTLS807X5
MHCXTNS809X3
MHCXTNS80011
MHCXTOS80015
MHCXTPS8018X5
MHCXTQS80022
MHCXTRS80030
MHCXTSS80037
MHCXTTS80045
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Frame
MH132MZA8
Cat. Ref.
MHCXTJS80003
MHLP 1A
R e v i s i o n - 6
Frame
MHF56ZAA2
MHF56ZBA2
MHF63ZAA2
MHF63ZBA2
MHF71ZAA2
MHF71ZBA2
MHF80ZAA2
MHF80ZBA2
MHF90SAA2
MHF90LCA2
MHF100LAA2
MHF100LBA2
MHF132SYA2
MHF132SZA2
MHF160MTA2
MHF160MVA2
MHF160MXA2
MHF160LXA2
MHF180MXG2
MHF200LLG2
MHF200LNG2
MHF225MN2
MHF250MN2
MHF280ST2
MHF280MT2
Cat. Ref.
MHHXTAF20X09
MHHXTAF20X12
MHHXTBF20X18
MHHXTBF20X25
MHHXTCF20X37
MHHXTCF20X55
MHHXTDF20X75
MHHXTDF201X1
MHCXTEF201X5
MHCXTFF202X2
MHCXTGF20003
MHCXTGF203X7
MHCXTIF205X5
MHCXTIF207X5
MHCXTKF209X3
MHCXTKF20011
MHCXTKF20015
MHCXTLF2018X5
MHCXTMF20022
MHCXTOF20030
MHCXTOF20037
MHCXTQF20045
MHCXTRF20055
MHCXTSF20075
MHCXTTF20090
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Frame
MHF63ZCA2
MHF71ZCA2
MHF80ZCA2
MHF90SBA2
MHF90LDA2
MHF112MAA2
MHF100LCA2
MHF112MBA2
MHF132MZA2
MHF132MRA2
MHF132MTA2
MHF160LRA2
MHF180MRG2
Cat. Ref.
MHHXTBF20X37
MHHXTCF20X75
MHHXTDF201X5
MHCXTEF201X8
MHCXTFF20003
MHCXTHF203X7
MHCXTGF205X5
MHCXTHF205X5
MHCXTJF209X3
MHCXTJF20011
MHCXTJF20015
MHCXTLF20022
MHCXTMF20030
MHLP 1A
R e v i s i o n - 6
10
Kw
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
Frame
MHF56ZAA4
MHF56ZBA4
MHF63ZAA4
MHF63ZBA4
MHF71ZAA4
MHF71ZBA4
MHF80ZAA4
MHF80ZBA4
MHF90SAA4
MHF90LBA4
MHF100LAA4
MHF112MAA4
MHF132SZA4
MHF132MZA4
MHF160MYA4
MHF160MXA4
MHF160LXA4
MHF180MXG4
MHF180LXG4
MHF200LNG4
MHF225SN4
MHF225MN4
MHF250MN4
MHF280ST4
MHF280MT4
Cat. Ref.
MHHXTAF40X06
MHHXTAF40X09
MHHXTBF40X12
MHHXTBF40X18
MHHXTBF40X25
MHHXTCF40X37
MHHXTDF40X55
MHHXTDF40X75
MHCXTEF401X1
MHCXTFF401X5
MHCXTGF402X2
MHCXTHF403X7
MHCXTIF405X5
MHCXTJF407X5
MHCXTKF409X3
MHCXTKF40011
MHCXTLF40015
MHCXTMF4018X5
MHCXTNF40022
MHCXTOF40030
MHCXTPF40037
MHCXTQF40045
MHCXTRF40055
MHCXTSF40075
MHCXTTF40090
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Kw
Hp
Frame
Cat. Ref.
0.25*
0.33
MHF63ZCA4
MHHXTBF40X25
0.55
0.75
MHF71ZCA4
MHHXTCF40X55
1.1
1.5
MHF80ZCA4
MHHXTDF401X1
1.8
2.5
MHF90LCA4
MHCXTFF401X8
2.2
3.00
MHF90LDA4
MHCXTFF402X2
3.0*
4.00
MHF100LBA4
MHCXTGF40003
3.7
5.00
MHF100LCA4
MHCXTGF403X7
5.5
7.5
MHF112MBA4
MHCXTHF405X5
9.3
12.5
MHF132MRA4
MHCXTJF409X3
11
15.00
MHF132MTA4
MHCXTJF40011
30
40.00
MHF180LRG4
MHCXTNF40030
37
50.00
MHF200LFG4
MHCXTOF40037
75
100.00
MHF250MK4
MHCXTRF40075
* Class F insulation with temperature rise limited to Class B
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 6
Frame
MHF71ZAA6
MHF80ZAA6
MHF80ZBA6
MHF90SAA6
MHF90LBA6
MHF100LAA6
MHF112MAA6
MHF132SYA6
MHF132MZA6
MHF160MZA6
MHF160LYA6
MHF160LZA6
MHF180LZG6
MHF200LPG6
MHF200LRG6
MHF225MP6
MHF250MP6
MHF280SV6
MHF280MV6
Cat. Ref.
MHHXTCF60X18
MHHXTDF60X37
MHHXTDF60X55
MHCXTEF60X75
MHCXTFF601X1
MHCXTGF601X5
MHCXTHF602X2
MHCXTIF603X7
MHCXTJF605X5
MHCXTKF607X5
MHCXTLF609X3
MHCXTLF60011
MHCXTNF60015
MHCXTOF6018X5
MHCXTOF60022
MHCXTQF60030
MHCXTRF60037
MHCXTSF60045
MHCXTTF60055
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Frame
MHF71ZBA6
MHF100LBA6
MHF112MBA6
MHF132SZA6
MHF132MTA6
Cat. Ref.
MHHXTCF60X25
MHCXTGF601X8
MHCXTHF60003
MHCXTIF60003
MHCXTJF607X5
11
MHLP 1A
R e v i s i o n - 6
12
Kw
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
Frame
MHF71ZAA8
MHF80ZAA8
MHF90SAA8
MHF90LBA8
MHF100LAA8
MHF100LBA8
MHF112MAA8
MHF132SZA8
MHF160MYA8
MHF160MZA8
MHF160LZA8
MHF180LYG8
MHF180LZG8
MHF200LRG8
MHF225SP8
MHF225MP8
MHF250MP8
MHF280SV8
MHF280MV8
Cat. Ref.
MHHXTCF80X12
MHHXTDF80X25
MHCXTEF80X37
MHCXTFF80X55
MHCXTGF80X75
MHCXTGF801X1
MHCXTHF801X5
MHCXTIF802X2
MHCXTKF803X7
MHCXTKF805X5
MHCXTLF807X5
MHCXTNS809X3
MHCXTNF80011
MHCXTOF80015
MHCXTPF8018X5
MHCXTQF80022
MHCXTRF80030
MHCXTSF80037
MHCXTTF80045
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost and are
listed in EFF1 pricelist
Frame
MHF132MZA8
Cat. Ref.
MHCXTJF80003
MHLP 1A
R e v i s i o n - 6
Kw
Hp
Frame
Cat. Ref.
List Price Rs.
0.09
0.12
MHHE56ZAA2
MHHETAS20X09
7,600
0.12
0.16
MHHE56ZBA2
MHHETAS20X12
7,790
0.18
0.25
MHHE63ZAA2
MHHETBS20X18
9,020
0.25
0.33
MHHE63ZBA2
MHHETBS20X25
9,280
0.37
0.5
MHHE71ZAA2
MHHETCS20X37
9,810
0.55
0.75
MHHE71ZBA2
MHHETCS20X55
10,845
0.75
1.00
MHHE80ZAA2
MHHETDS20X75
11,260
1.1
1.5
MHHE80ZBA2
MHHETDS201X1
12,300
1.5
2.00
MHHE90SAA2
MHCETES201X5
14,145
2.2
3.00
MHHE90LCA2
MHCETFS202X2
18,170
3
4.00
MHHE100LAA2
MHCETGS20003
21,335
3.7
5.00
MHHE100LBA2
MHCETGS203X7
22,325
5.5
7.5
MHHE132SYA2
MHCETIS205X5
36,600
7.5
10.00
MHHE132SZA2
MHCETIS207X5
37,925
9.3
12.5
MHHE160MTA2
MHCETKS209X3
64,980
11
15.00
MHHE160MVA2
MHCETKS20011
66,250
15
20.00
MHHE160MXA2
MHCETKS20015
77,670
18.5
25.00
MHHE160LXA2
MHCETLS2018X5
1,00,815
22
30.00
MHHE180MXG2
MHCETMS20022
1,07,520
30
40.00
MHHE200LLG2
MHCETOS20030
1,59,935
37
50.00
MHHE200LNG2
MHCETOS20037
1,95,110
45
60.00
MHHE225MN2
MHCETQS20045
2,51,105
55
75.00
MHHE250MN2
MHCETRS20055
3,38,065
75
100.00
MHHE280ST2
MHCETSS20075
4,20,210
90
125.00
MHHE280MT2
MHCETTS20090
4,87,060
110
150.00
MHHE315SYE2
MHCETUS20110
6,15,200
132
180.00
MHHE315MZE2
MHCETVS20132
7,56,100
160
220.00
MHHE315LYE2
MHCETWS20160
8,27,500
200
270.00
MHHE315LZE2
MHCETWS20200
9,66,500
225
300.00
MHHE355MA2
MHCETYS20225
10,22,300
250
340.00
MHHE355MB2
MHCETYS20250
10,77,400
275
370.00
MHHE355LA2
MHCETZS20275
11,46,490
315
425.00
MHHE355LB2
MHCETZS20315
11,74,000
335
455.00
MHHE355LC2
MHCETZS20335
13,39,900
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Intermediate Ratings (Class F insulation with temperature rise limited to Class F)
Output
2 Pole - 3000 RPM
Kw
Hp
Frame
Cat. Ref.
0.37
0.5
MHHE63ZCA2
MHHETBS20X37
0.75
1.00
MHHE71ZCA2
MHHETCS20X75
1.5
2.00
MHHE80ZCA2
MHHETDS201X5
1.8*
2.5
MHHE90SBA2
MHCETES201X8
3
4.00
MHHE90LDA2
MHCETFS20003
3.7*
5.00
MHHE112MAA2
MHCETHS203X7
5.5*
7.5
MHHE100LCA2
MHCETGS205X5
5.5
7.5
MHHE112MBA2
MHCETHS205X5
9.3
12.5
MHHE132MZA2
MHCETJS209X3
11*
15.00
MHHE132MRA2
MHCETJS20011
15
20.00
MHHE132MTA2
MHCETJS20015
22
30.00
MHHE160LRA2
MHCETLS20022
30
40.00
MHHE180MRG2
MHCETMS20030
* Class F insulation with temperature rise limited to Class B
Excise duty including cess will be charged as applicable at the time of dispatch
13
MHLP 1A
R e v i s i o n - 6
14
Kw
Hp
Frame
Cat. Ref.
List Price Rs.
0.06
0.08
MHHE56ZAA4
MHHETAS40X06
8,410
0.09
0.12
MHHE56ZBA4
MHHETAS40X09
8,455
0.12
0.16
MHHE63ZAA4
MHHETBS40X12
8,590
0.18
0.25
MHHE63ZBA4
MHHETBS40X18
9,875
0.25
0.33
MHHE71ZAA4
MHHETCS40X25
9,950
0.37
0.5
MHHE71ZBA4
MHHETCS40X37
10,370
0.55
0.75
MHHE80ZAA4
MHHETDS40X55
11,555
0.75
1.00
MHHE80ZBA4
MHHETDS40X75
11,670
1.1
1.5
MHHE90SAA4
MHCETES401X1
13,310
1.5
2.00
MHHE90LBA4
MHCETFS401X5
14,500
2.2
3.00
MHHE100LAA4
MHCETGS402X2
19,240
3.7
5.00
MHHE112MAA4
MHCETHS403X7
24,670
5.5
7.5
MHHE132SZA4
MHCETIS405X5
33,990
7.5
10.00
MHHE132MZA4
MHCETJS407X5
39,610
9.3
12.5
MHHE160MYA4
MHCETKS409X3
62,100
11
15.00
MHHE160MXA4
MHCETKS40011
63,480
15
20.00
MHHE160LXA4
MHCETLS40015
78,900
18.5
25.00
MHHE180MXG4
MHCETMS4018X5
1,01,950
22
30.00
MHHE180LXG4
MHCETNS40022
1,13,630
30
40.00
MHHE200LNG4
MHCETOS40030
1,53,410
37
50.00
MHHE225SN4
MHCETPS40037
1,88,410
45
60.00
MHHE225MN4
MHCETQS40045
2,28,380
55
75.00
MHHE250MN4
MHCETRS40055
3,13,875
75
100.00
MHHE280ST4
MHCETSS40075
3,83,830
90
125.00
MHHE280MT4
MHCETTS40090
4,44,990
110
150.00
MHHE315SYE4
MHCETUS40110
5,39,000
132
180.00
MHHE315MYE4
MHCETVS40132
6,34,300
160
220.00
MHHE315MZE4
MHCETVS40160
7,41,000
200
270.00
MHHE315LZE4
MHCETWS40200
9,04,000
225
300.00
MHHE355MA4
MHCETYS40225
9,25,000
250
340.00
MHHE355MB4
MHCETYS40250
9,96,000
275
370.00
MHHE355MC4
MHCETYS40275
10,08,500
315
425.00
MHHE355LA4
MHCETZS40315
11,40,000
335
450.00
MHHE355LB4
MHCETZS40335
12,33,000
350
470.00
MHHE355LC4
MHCETZS40350
14,70,000
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Intermediate Ratings (Class F insulation with temperature rise limited to Class F)
Output
4 Pole - 1500 RPM
Kw
Hp
Frame
Cat. Ref.
0.25*
0.33
MHHE63ZCA4
MHHETBS40X25
0.55
0.75
MHHE71ZCA4
MHHETCS40X55
1.1
1.5
MHHE80ZCA4
MHHETDS401X1
1.8
2.5
MHHE90LCA4
MHCETFS401X8
2.2
3.00
MHHE90LDA4
MHCETFS402X2
3.0*
4.00
MHHE100LBA4
MHCETGS40003
3.7
5.00
MHHE100LCA4
MHCETGS403X7
5.5
7.5
MHHE112MBA4
MHCETHS405X5
9.3
12.5
MHHE132MRA4
MHCETJS409X3
11
15.00
MHHE132MTA4
MHCETJS40011
30
40.00
MHHE180LRG4
MHCETNS40030
37
50.00
MHHE200LFG4
MHCETOS40037
75
100.00
MHHE250MK4
MHCETRS40075
* Class F insulation with temperature rise limited to Class B
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 6
Frame
MHHE71ZAA6
MHHE80ZAA6
MHHE80ZBA6
MHHE90SAA6
MHHE90LBA6
MHHE100LAA6
MHHE112MAA6
MHHE132SYA6
MHHE132MZA6
MHHE160MZA6
MHHE160LYA6
MHHE160LZA6
MHHE180LZG6
MHHE200LPG6
MHHE200LRG6
MHHE225MP6
MHHE250MP6
MHHE280SV6
MHHE280MV6
MHHE315SYE6
MHHE315MYE6
MHHE315MZE6
MHHE315LZE6
MHHE355MA6
MHHE355MB6
MHHE355MC6
MHHE355LA6
MHHE355LB6
Cat. Ref.
MHHETCS60X18
MHHETDS60X37
MHHETDS60X55
MHCETES60X75
MHCETFS601X1
MHCETGS601X5
MHCETHS602X2
MHCETIS603X7
MHCETJS605X5
MHCETKS607X5
MHCETLS609X3
MHCETLS60011
MHCETNS60015
MHCETOS6018X5
MHCETOS60022
MHCETQS60030
MHCETRS60037
MHCETSS60045
MHCETTS60055
MHCETUS60075
MHCETVS60090
MHCETVS60110
MHCETWS60132
MHCETYS60160
MHCETYS60180
MHCETYS60200
MHCETZS60250
MHCETZS60315
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Frame
MHHE71ZBA6
MHHE100LBA6
MHHE112MBA6
MHHE132SZA6
MHHE132MTA6
Cat. Ref.
MHHETCS60X25
MHCETGS601X8
MHCETHS60003
MHCETHS60003
MHCETJS607X5
15
MHLP 1A
R e v i s i o n - 6
16
Kw
Hp
Frame
Cat. Ref.
List Price Rs.
0.12
0.16
MHHE71ZAA8
MHHETCS80X12
11,610
0.25
0.33
MHHE80ZAA8
MHHETDS80X25
13,325
0.37
0.5
MHHE90SAA8
MHCETES80X37
13,610
0.55
0.75
MHHE90LBA8
MHCETFS80X55
14,915
0.75
1.00
MHHE100LAA8
MHCETFS80X75
18,345
1.1
1.5
MHHE100LBA8
MHCETGS801X1
22,360
1.5
2.00
MHHE112MAA8
MHCETHS801X5
25,890
2.2
3.00
MHHE132SZA8
MHCETIS802X2
34,235
3.7
5.00
MHHE160MYA8
MHCETKS803X7
62,000
5.5
7.5
MHHE160MZA8
MHCETKS805X5
65,450
7.5
10.00
MHHE160LZA8
MHCETLS807X5
83,050
9.3
12.5
MHHE180LYG8
MHCETNS809X3
1,03,310
11
15.00
MHHE180LZG8
MHCETNS80011
1,08,920
15
20.00
MHHE200LRG8
MHCETOS80015
1,53,435
18.5
25.00
MHHE225SP8
MHCETPS8018X5
1,98,770
22
30.00
MHHE225MP8
MHCETQS80022
2,39,920
30
40.00
MHHE250MP8
MHCETRS80030
3,22,660
37
50.00
MHHE280SV8
MHCETSS80037
3,93,660
45
60.00
MHHE280MV8
MHCETTS80045
4,57,020
55
75.00
MHHE315SYE8
MHCETUS80055
5,30,000
75
100.00
MHHE315MYE8
MHCETVS80075
6,61,400
90
125.00
MHHE315LZE8
MHCETWS80110
7,46,300
110
150.00
MHHE315LZE8
MHCETWS80110
7,90,000
132
180.00
MHHE355MA8
MHCETYS80132
9,19,810
150
200.00
MHHE355MB8
MHCETYS80150
10,36,430
160
220.00
MHHE355MC8
MHCETYS80160
10,63,560
180
240.00
MHHE355LA8
MHCETZS80180
10,86,030
200
270.00
MHHE355LB8
MHCETZS80200
11,63,450
250
340.00
MHHE355LC8
MHCETZS80250
18,08,140
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Hp
4.00
Frame
MHHE132MZA8
Cat. Ref.
MHCETJS80003
MHLP 1A
R e v i s i o n - 6
Frame
MHHF56ZAA2
MHHF56ZBA2
MHHF63ZAA2
MHHF63ZBA2
MHHF71ZAA2
MHHF71ZBA2
MHHF80ZAA2
MHHF80ZBA2
MHHF90SAA2
MHHF90LCA2
MHHF100LAA2
MHHF100LBA2
MHHF132SYA2
MHHF132SZA2
MHHF160MTA2
MHHF160MVA2
MHHF160MXA2
MHHF160LXA2
MHHF180MXG2
MHHF200LLG2
MHHF200LNG2
MHHF225MN2
MHHF250MN2
MHHF280ST2
MHHF280MT2
MHHF315SYE2
MHHF315MZE2
MHHF315LYE2
MHHF315LZE2
MHHF355MA2
MHHF355MB2
MHHF355LA2
MHHF355LB2
MHHF355LC2
Cat. Ref.
MHHETAF20X09
MHHETAF20X12
MHHETBF20X18
MHHETBF20X25
MHHETCF20X37
MHHETCF20X55
MHHETDF20X75
MHHETDF201X1
MHCETEF201X5
MHCETFF202X2
MHCETGF20003
MHCETGF203X7
MHCETIF205X5
MHCETIF207X5
MHCETKF209X3
MHCETKF20011
MHCETKF20015
MHCETLF2018X5
MHCETMF20022
MHCETOF20030
MHCETOF20037
MHCETQF20045
MHCETRF20055
MHCETSF20075
MHCETTF20090
MHCETUF20110
MHCETVF20132
MHCETWF20160
MHCETWF20200
MHCETYS20225
MHCETYS20250
MHCETZS20275
MHCETZS20315
MHCETZS20335
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Frame
MHHF63ZCA2
MHHF71ZCA2
MHHF80ZCA2
MHHF90SBA2
MHHF90LDA2
MHHF112MAA2
MHHF100LCA2
MHHF112MBA2
MHHF132MZA2
MHHF132MRA2
MHHF132MTA2
MHHF160LRA2
MHHF180MRG2
Cat. Ref.
MHHETBS20X37
MHHETCS20X75
MHHETDS201X5
MHCETEF201X8
MHCETFF20003
MHCETHF203X7
MHCETGF205X5
MHCETHF205X5
MHCETJF209X3
MHCETJF20011
MHCETJF20015
MHCETLF20022
MHCETMF20030
17
MHLP 1A
R e v i s i o n - 6
18
Kw
Hp
Frame
Cat. Ref.
List Price Rs.
0.06
0.08
MHHF56ZAA4
MHHETAF40X06
8,660
0.09
0.12
MHHF56ZBA4
MHHETAF40X09
8,710
0.12
0.16
MHHF63ZAA4
MHHETBF40X12
8,845
0.18
0.25
MHHF63ZBA4
MHHETBF40X18
10,170
0.25
0.33
MHHF71ZAA4
MHHETBF40X25
10,250
0.37
0.5
MHHF71ZBA4
MHHETCF40X37
10,680
0.55
0.75
MHHF80ZAA4
MHHETDF40X55
11,900
0.75
1.00
MHHF80ZBA4
MHHETDF40X75
12,020
1.1
1.5
MHHF90SAA4
MHCETEF401X1
13,710
1.5
2.00
MHHF90LBA4
MHCETFF401X5
14,935
2.2
3.00
MHHF100LAA4
MHCETGF402X2
19,815
3.7
5.00
MHHF112MAA4
MHCETHF403X7
25,410
5.5
7.5
MHHF132SZA4
MHCETIF405X5
35,010
7.5
10.00
MHHF132MZA4
MHCETJF407X5
40,700
9.3
12.5
MHHF160MYA4
MHCETKF409X3
63,965
11
15.00
MHHF160MXA4
MHCETKF40011
65,385
15
20.00
MHHF160LXA4
MHCETLF40015
81,265
18.5
25.00
MHHF180MXG4
MHCETMF4018X5
1,07,045
22
30.00
MHHF180LXG4
MHCETNF40022
1,19,310
30
40.00
MHHF200LNG4
MHCETOF40030
1,61,080
37
50.00
MHHF225SN4
MHCETPF40037
1,97,830
45
60.00
MHHF225MN4
MHCETQF40045
2,39,800
55
75.00
MHHF250MN4
MHCETRF40055
3,29,570
75
100.00
MHHF280ST4
MHCETSF40075
4,03,020
90
125.00
MHHF280MT4
MHCETTF40090
4,67,240
110
150.00
MHHF315SYE4
MHCETUF40110
5,65,950
132
180.00
MHHF315MYE4
MHCETVF40132
6,66,015
160
220.00
MHHF315MZE4
MHCETVF40160
7,78,050
200
270.00
MHHF315LZE4
MHCETWF40200
9,49,200
225
300.00
MHHF355MA4
MHCETYF40225
9,71,250
250
340.00
MHHF355MB4
MHCETYF40250
10,45,800
275
370.00
MHHF355MC4
MHCETYF40275
10,58,925
315
425.00
MHHF355LA4
MHCETZF40315
11,97,000
335
450.00
MHHF355LB4
MHCETZF40335
12,94,650
350
470.00
MHHF355LC4
MHCETZF40350
15,43,500
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Intermediate Ratings (Class F insulation with temperature rise limited to Class F)
Output
4 Pole - 1500 RPM
Kw
Hp
Frame
Cat. Ref.
0.25*
0.33
MHHF63ZCA4
MHCETBF40X25
0.55
0.75
MHHF71ZCA4
MHCETCF40X55
1.1
1.5
MHHF80ZCA4
MHCETDF401X1
1.8
2.5
MHHF90LCA4
MHCETFF401X8
2.2
3.00
MHHF90LDA4
MHCETFF402X2
3.0*
4.00
MHHF100LBA4
MHCETGF40003
3.7
5.00
MHHF100LCA4
MHCETGF403X7
5.5
7.5
MHHF112MBA4
MHCETHF405X5
9.3
12.5
MHHF132MRA4
MHCETJF409X3
11
15.00
MHHF132MTA4
MHCETJF40011
30
40.00
MHHF180LRG4
MHCETNF40030
37
50.00
MHHF200LFG4
MHCETOF40037
75
100.00
MHHF250MK4
MHCETRF40075
* Class F insulation with temperature rise limited to Class B
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 6
Frame
MHHF71ZAA6
MHHF80ZAA6
MHHF80ZBA6
MHHF90SAA6
MHHF90LBA6
MHHF100LAA6
MHHF112MAA6
MHHF132SYA6
MHHF132MZA6
MHHF160MZA6
MHHF160LYA6
MHHF160LZA6
MHHF180LZG6
MHHF200LPG6
MHHF200LRG6
MHHF225MP6
MHHF250MP6
MHHF280SV6
MHHF280MV6
MHHF315SYE6
MHHF315MYE6
MHHF315MZE6
MHHF315LZE6
MHHF355MA6
MHHF355MB6
MHHF355MC6
MHHF355LA6
MHHF355LB6
Cat. Ref.
MHHETCF60X18
MHHETDF60X37
MHHETDF60X55
MHCETEF60X75
MHCETFF601X1
MHCETGF601X5
MHCETHF602X2
MHCETIF603X7
MHCETJF605X5
MHCETKF607X5
MHCETLF609X3
MHCETLF60011
MHCETNF60015
MHCETOF6018X5
MHCETOF60022
MHCETQF60030
MHCETRF60037
MHCETSF60045
MHCETTF60055
MHCETUF60075
MHCETVF60090
MHCETVF60110
MHCETWF60132
MHCETYF60160
MHCETYF60180
MHCETYF60200
MHCETZF60250
MHCETZF60315
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
19
MHLP 1A
R e v i s i o n - 6
20
Kw
0.12
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
37
45
55
75
90
110
132
150
160
180
200
250
Frame
MHHF71ZAA8
MHHF80ZAA8
MHHF90SAA8
MHHF90LBA8
MHHF100LAA8
MHHF100LBA8
MHHF112MAA8
MHHF132SZA8
MHHF160MYA8
MHHF160MZA8
MHHF160LZA8
MHHF180LYG8
MHHF180LZG8
MHHF200LRG8
MHHF225SP8
MHHF225MP8
MHHF250MP8
MHHF280SV8
MHHF280MV8
MHHF315SYE8
MHHF315MYE8
MHHF315MZE8
MHHF315LZE8
MHHF355MA8
MHHF355MB8
MHHF355MC8
MHHF355LA8
MHHF355LB8
MHHF355LC8
Cat. Ref.
MHHETCF80X12
MHHETDF80X25
MHCETEF80X37
MHCETFF80X55
MHCETGF80X75
MHCETGF801X1
MHCETHF801X5
MHCETIF802X2
MHCETKF803X7
MHCETKF805X5
MHCETLF807X5
MHCETNS809X3
MHCETNF80011
MHCETOF80015
MHCETPF8018X5
MHCETQF80022
MHCETRF80030
MHCETSF80037
MHCETTF80045
MHCETUF80055
MHCETVF80075
MHCETVF80090
MHCETWF80110
MHCETYF80132
MHCETYF80150
MHCETYF80160
MHCETZF80180
MHCETZF80200
MHCETZF80250
Note: Havells standard motors in frame 315 and above are EFF1 at no extra cost
Hp
4.00
Frame
MHHF132MZA8
Cat. Ref.
MHCETJF80003
1.1
Non standard single/ double shaft extension, diameter of shaft being same or
1.2
Shaft material - EN 24
10% of LP
1.3
15% of LP
Mounting
Standard flange or face mounting (B14, B5, V1, V18 & V19) or foot cum
2.1
Up to frame 160
3% of LP
2.2
5% of LP
3.1
Epoxy
3.1.1
3% of LP
3.1.2
5% of LP
3.2
Non-Epoxy
3.3
Paint Thickness
Nil
4% of LP
6% of LP
2% of LP
Insulation Class H
10% of LP
5% of LP
8.1
Nil
8.2
3% of LP
9.1
Single Tapped winding type motor upto 8 Pole (to be taken on higher frame).
9.2
10
9 Leads / 12 Leads
3% of LP
11
Enclosure / Types
11.1
IP 56
12
Space Heaters
12.1
Up to Frame 160
12.2
12.3
13
13.1
3 Nos.
13.2
6 Nos.
14
RTD
14.1
14.2
Extra Charges
5% of LP
5% of LP subject to max of
5% of LP
21
22
S. No.
Extra Charges
14.3
14.4
15
15.1
16
Cable Glands
16.1
Frame 71-132
Frame 160-225
Frame 250-355
16.2
Frame 71-132
Frame 160-225
Frame 250-355
17
Frame 355
Rs.28000/- Net
18
Special Bearings
18.1
Rs.33000/- Net
Rs.35000/- Net
Rs.37000/-Net
Rs.40,000/-Net
18.2
Rs.1300/- Net
Rs.2300/- Net
Rs.3200/- Net
Frame 355
Rs.4500/- Net
19
Vibration Level
Precesion Class A
10% of LP
Precesion Class B
20% of LP
20
20.1
Frame 56-132
Frame 160-225
Frame 250-355
20.2
Frame 56-132
Frame 160-225
Frame 250-280
20.3
Frame 56-355
20.4
112M FRAME
132M FRAME
160M FRAME
160L FRAME
180M FRAME
180L FRAME
200L FRAME
H
I
J
K
L
M
N
O
HE
ND
CX
NE
CE
NF
LX
NL
LE
NI
355S FRAME
355M FRAME
355L FRAME
X
Y
Z
315M FRAME
315L FRAME
V
W
315S FRAME
280M FRAME
MS
MN
280S FRAME
250M FRAME
KX
NK
225S FRAME
0 (Zero)
225M FRAME
10pole
B
C
132S FRAME
90L FRAME
100L FRAME
F
G
FX
NC
8pole
6 pole
2
4
2 pole
4 pole
S
F
80 FRAME
90S FRAME
63 FRAME
71 FRAME
B
C
D
NB
T
Z
9,10,11,12
Polarity KW Rating /
MX
FOR TE Enclosure
56 FRAME
MOUNTING
HX
NA
FRAME
7
Running Nos (Non Std.)
Enclosure
Type of Motor
3,4
23
Automatic Winding
CNC Machine
Painting Line
Testing
ZHMPL00002/JAN11/MAR11
NORTH - REGIONAL OFFICES : Delhi : QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-4771000, Fax: 0120-4772000,
Chandigarh : Tel: 0172-4232400 -401, Fax: 0172-4232403, Dehradun : Tel: 0135-2521025, 2521552, Haryana : Tel: 91-120 2477848 / 853, Fax: 0120-2583904,
Noida : Tel: 0120-3055609 / 3055610, Fax: 0120-3055611, Ludhiana : Tel: 0161-4676001 / 6024, Fax: 0161-46766007, Jammu:Tel:0191-2490424,
Fax: 0191-2490405, Jaipur : Tel: 0141-3988210, Fax: 0141-2389024, Lucknow: Tel: 0522-2201032, 2200938, Kanpur : Tel: Airtel: 09935533751/52/53, 05122690128/129/130, Fax: 0512-2692800, EAST - REGIONAL OFFICE : Kolkata : ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata 700 001, Tel: 033-40129851/52,
Fax: 033-40127339, Bhubaneshwar : Tel: 0674-2598104, 2598105, 2598106, Fax: 0674-2598107, Guwahati : Tel: 0361-2134521, 2458923, Fax: 0361-2460355,
Siliguri : Tel: 0353-2525907-3290402 (RIM), Jamshedpur : Tel: 0657-6542492, 09234369436, Patna : Tel: 0612-3244218, 2655519, Telefax: 0612-2655518
WEST - REGIONAL OFFICE : Mumbai : 302, Boston House, 3rd Floor Suren Road, CTS No. 260/261, Andheri (E)-Mumbai-400 093, Tel: 022-67298600-603,
Ahmedabad : Tel: 079-40061111, 40060738-740, Fax: 079-40060741, Indore : Tel: 0731-2572340-41, 4009998 (Airtel), Fax: 0731-2551626, Rajkot : Tel: 0281
3013289 / 3013290, Nagpur : Tel: 0712-2224132, 2222692, 2222029 Pune : Tel: 020-64016413/14, Raipur : Tel: 0771-4243400 / 01, Telefax: 0771-4243402,
Surat : Telefax: 0261-2350137 SOUTH - REGIONAL OFFICE : Chennai : Block 1, A & D Wing, Shakthi Towers, 7th Floor, 766, Annna Salai, Chennai 600
002, Tel: 044-28526941-44, Fax: 044-28524326,Bangalore : Tel: 080-39882100, 30515801 / 2 / 3 /4, Fax: 080-30515804, Coimbatore : Telefax: 0422-2305767,
2306199, 2305199, Hyderabad : Tel: 040-27533372, 27533355, 27533632, 66320407/0408/6401/6402, Fax: 040-27533211, Kochi : Tel.: 0484-4099000,
2393165, 2393068, Fax: 0484-2393170, Vishakapatnam : Tel: 0891-6514339, Fax: 0891-2522547
Representative Offices :
Goa Solapur Gwalior Jabalpur Hubli Davanagere Gulbarga Mysore Trichy Kathmandu Sambalpur Jalandhar Bhopal Calicut
Madurai Trivandrum
Terms & Conditions :
o List prices are valid for delivery from our godown/factory.
o The list prices are exclusive of Excise Duties, Sales Tax and any other Central or Local Taxes, Octroi Duty and other levies. These will be charged extra as applicable on
the day of supply.
o Insurance charges are included in the prices.
o In our endeavour to continuously improve the product from time to time, frame sizes indicated are provisional and subject to change without notice.
o The price list is subject to our Standard General Terms and Conditions of Tender and sale and the prices are subject to revision without prior notice.
o Minimum order value acceptable is ` 20,000/-
Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-4771000,
E-mail: marketing@havells.com, www.havells.com
Consumer Care No.: 1800 11 0303 (Tollfree), 011-4166 0303 (Landline)
1800 103 1313 (All Connections)
Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!
Energy Efficient
3 Phase
LV Induction Motors
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty without Encoder Arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
Frame
0.75
MH80ZAA2
18,160
1.1
1.5
MH80ZBA2
19,210
1.5
MH90SAA2
23,265
1.8*
2.5
MH90SBA2
25,175
2.2
MH90LCA2
26,755
MH100LAA2
30,090
3.7
MH100LBA2
31,880
3.7*
5.5
MH112MAA2
35,725
5.5
7.5
MH132SYA2
46,075
7.5
10
MH132SZA2
47,530
9.3
12.5
MH160MTA2
76,065
11
15
MH160MVA2
76,065
15
20
MH160MXA2
86,535
18.5
25
MH160LXA2
1,07,570
22
30
MH180MXG2
1,20,530
30
40
MH200LLG2
1,74,305
37
50
MH200LNG2
2,07,940
45
60
MH225MN2
2,64,790
55
75
MH250MN2
3,53,770
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD
Treatment Without Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty without Encoder Arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
0.55
0.75
MH80ZAA4
18,540
0.75
MH80ZBA4
18,555
1.1
1.5
MH90SAA4
22,555
1.5
MH90LBA4
23,690
2.2
MH100LAA4
29,050
3.7
MH112MAA4
34,150
5.5
7.5
MH132SZA4
43,890
Frame
7.5
10
MH132MZA4
49,165
9.3
12.5
MH160MYA4
73,055
11
15
MH160MXA4
73,480
15
20
MH160LXA4
87,830
18.5
25
MH180MXG4
1,15,200
22
30
MH180LXG4
1,27,230
30
40
MH200LNG4
1,68,180
37
50
MH225SN4
2,03,690
45
60
MH225MN4
2,42,750
55
75
MH250MN4
3,30,560
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD Treatment
Without Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty without Encoder Arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
Frame
0.37
0.5
MH80ZAA6
19,175
0.55
0.75
MH80ZBA6
19,330
0.75
MH90SAA6
23,405
1.1
1.5
MH90LBA6
24,630
1.5
MH100LAA6
29,080
2.2
MH112MAA6
32,775
3.7
MH132SYA6
45,575
5.5
7.5
MH132MZA6
49,980
7.5
10
MH160MZA6
75,215
9.3
12.5
MH160LYA6
77,015
11
15
MH160LZA6
90,095
15
20
MH180LZG6
1,19,705
18.5
25
MH200LPG6
1,52,730
22
30
MH200LRG6
1,64,310
30
40
MH225MP6
2,49,330
37
50
MH250MP6
3,32,830
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD Treatment
Without Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty without Encoder Arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
0.25
0.33
MH80ZAA8
19,890
0.37
0.5
MH90SAA8
21,720
0.55
0.75
MH90LBA8
22,870
0.75
MH100LAA8
27,640
1.1
1.5
MH100LBA8
31,300
1.5
MH112MAA8
34,750
2.2
MH132SZA8
43,520
3.7
MH160MYA8
63,750
5.5
7.5
MH160MZA8
75,275
Frame
7.5
10
MH160LZA8
91,810
9.3
12.5
MH180LYG8
1,16,260
11
15
MH180LZG8
1,21,995
15
20
MH200LRG8
1,67,400
18.5
25
MH225SP8
2,13,760
22
30
MH225MP8
2,54,075
30
40
MH250MP8
3,38,995
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD
Treatment Without Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty with encoder arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
Frame
0.75
MH80ZAA2
18,620
1.1
1.5
MH80ZBA2
19,725
1.5
MH90SAA2
23,875
1.8*
2.5
Inv.
25,875
2.2
MH90LCA2
27,525
MH100LAA2
30,995
3.7
MH100LBA2
32,850
3.7*
5.5
MH112MAA2
36,900
5.5
7.5
MH132SYA2
47,658
7.5
10
MH132SZA2
49,180
9.3
12.5
MH160MTA2
78,950
11
15
MH160MVA2
78,950
15
20
MH160MXA2
89,900
18.5
25
MH160LXA2
1,11,950
22
30
MH180MXG2
1,25,400
30
40
MH200LLG2
1,81,565
37
50
MH200LNG2
2,16,790
45
60
MH225MN2
2,76,200
55
75
MH250MN2
3,69,110
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD Treatment
With Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty with encoder arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
0.55
0.75
MH80ZAA4
19,020
0.75
MH80ZBA4
19,020
1.1
1.5
MH90SAA4
23,130
1.5
MH90LBA4
24,320
2.2
MH100LAA4
29,890
3.7
MH112MAA4
35,220
5.5
7.5
MH132SZA4
45,360
Frame
7.5
10
MH132MZA4
50,880
9.3
12.5
MH160MYA4
75,790
11
15
MH160MXA4
76,240
15
20
MH160LXA4
91,255
18.5
25
MH180MXG4
1,19,825
22
30
MH180LXG4
1,32,385
30
40
MH200LNG4
1,75,155
37
50
MH225SN4
2,12,255
45
60
MH225MN4
2,53,125
55
75
MH250MN4
3,44,830
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD Treatment
With Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty with encoder arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
Frame
0.37
0.5
MH80ZAA6
19,675
0.55
0.75
MH80ZBA6
19,840
0.75
MH90SAA6
24,020
1.1
1.5
MH90LBA6
25,305
1.5
MH100LAA6
29,940
2.2
MH112MAA6
33,810
3.7
MH132SYA6
47,140
5.5
7.5
MH132MZA6
51,735
7.5
10
MH160MZA6
78,055
9.3
12.5
MH160LYA6
79,940
11
15
MH160LZA6
93,625
15
20
MH180LZG6
1,24,545
18.5
25
MH200LPG6
1,59,025
22
30
MH200LRG6
1,71,135
30
40
MH225MP6
2,60,020
37
50
MH250MP6
3,47,210
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD
Treatment With Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Inverter Duty with encoder arrangement
Motors - Foot / Flange / Foot cum flange Mounted
Continuously rated suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and
temperature rise limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and
conforming to IS 325:1996 / IS 12615:1999
Output
Kw
Hp
0.25
0.33
MH80ZAA8
20,425
0.37
0.5
MH90SAA8
22,285
0.55
0.75
MH90LBA8
23,480
0.75
MH100LAA8
28,435
1.1
1.5
MH100LBA8
32,255
1.5
MH112MAA8
36,885
2.2
MH132SZA8
45,005
3.7
MH160MYA8
66,085
5.5
7.5
MH160MZA8
78,110
Frame
7.5
10
MH160LZA8
95,430
9.3
12.5
MH180LYG8
1,20,945
11
15
MH180LZG8
1,26,935
15
20
MH200LRG8
1,74,370
18.5
25
MH225SP8
2,22,790
22
30
MH225MP8
2,64,970
30
40
MH250MP8
3,53,655
# List Price inclusive of 3 Phase External Forced Cooled Fan & VFD
Treatment With Encoder arrangement
# 3 Phase Forced Cooling Fans are Make of SEM,Bangalore
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Brake Motors
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Brake Motors - Foot / Flange / Foot Cum Flange Mounting
Suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and temperature rise
limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and conforming to IS
325:1996 / IS 12615:1999
Output
Kw
Hp
0.18
0.25
MHBY63ZAA2
15,880
0.25
0.33
MHBY63ZBA2
16,080
0.37
0.5
MHBY71ZAA2
17,880
0.55
0.75
MHBY71ZBA2
19,440
0.75
MHBY80ZAA2
19,830
1.1
1.5
MHBY80ZBA2
21,000
1.5
MHBY90SAA2
26,850
2.2
MHBY90LCA2
31,370
MHBY100LAA2
38,510
3.7
MHBY100LCA2
38,510
5.5
7.5
MHBY132SYA2
63,390
Frame
7.5
10
MHBY132SZA2
64,770
9.3
12.5
MHBY132MZA2
91,720
9.3
12.5
MHBY160MTA2
1,03,140
11
15
MHBY160MVA2
1,03,655
15
20
MHBY160MXA2
1,25,140
18.5
25
MHBY160LXA2
1,61,440
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Brake Motors
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Brake Motors - Foot / Flange / Foot Cum Flange Mounting
Suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and temperature rise
limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and conforming to IS
325:1996 / IS 12615:1999
Output
Kw
Hp
0.12
0.16
MHBY63ZAA4
16,235
0.18
0.25
MHBY63ZBA4
16,910
0.25
0.33
MHBY71ZAA4
18,010
0.37
0.5
MHBY71ZBA4
18,390
0.55
0.75
MHBY80ZAA4
20,240
0.75
MHBY80ZBA4
20,330
1.1
1.5
MHBY90SAA4
25,840
1.5
MHBY90LBA4
27,170
2.2
MHBY100LAA4
34,910
MHBY100LBA4
37,180
3.7
MHBY112MAA4
43,870
5.5
7.5
MHBY132SZA4
60,110
Frame
7.5
10
MHBY132MZA4
66,390
9.3
12.5
MHBY160MYA4
95,370
11
15
MHBY160MXA4
95,890
15
20
MHBY160LXA4
Excise duty including cess will be charged as applicable at the time of dispatch
1,20,045
10
MHLP 1A
R e v i s i o n - 4
Brake Motors
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Brake Motors - Foot / Flange / Foot Cum Flange Mounting
Suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and temperature rise
limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and conforming to IS
325:1996 / IS 12615:1999
11
Output
Kw
Hp
0.18
0.25
MHBY71ZAA6
17,310
0.25
0.33
MHBY71ZBA6
17,685
0.37
0.5
MHBY80ZAA6
20,980
0.55
0.75
MHBY80ZBA6
21,170
0.75
MHBY90SAA6
26,790
1.1
1.5
MHBY90LBA6
28,310
1.5
MHBY100LAA6
36,620
2.2
MHBY112MAA6
44,060
MHBY132SZA6
69,830
3.7
MHBY132SYA6
69,830
5.5
7.5
MHBY132MZA6
74,500
Frame
7.5
10
MHBY160MZA6
1,00,835
9.3
12.5
MHBY160LYA6
1,09,910
11
15
MHBY160LZA6
1,26,325
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Brake Motors
Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Brake Motors - Foot / Flange / Foot Cum Flange Mounting
Suitable for operation on 415 Volts 10%, 3 Phase, 50 Hz 5%, AC Supply with Class F insulation and temperature rise
limited to Class B, for an ambient of 50C and altitude less than 1000m above MSL, IP 55 Protection and conforming to IS
325:1996 / IS 12615:1999
Output
Kw
Hp
0.12
0.16
MHBY71ZAA8
20,655
0.25
0.33
MHBY80ZAA8
21,700
0.37
0.5
MHBY90SAA8
26,060
0.55
0.75
MHBY90LBA8
27,410
0.75
MHBY100LAA8
34,870
1.1
1.5
MHBY100LBA8
39,540
1.5
MHBY112MAA8
46,590
2.2
MHBY132SZA8
62,260
MHBY132MZA8
92,110
3.7
MHBY160MYA8
90,140
5.5
7.5
MHBY160MZA8
1,00,900
MHBY160LZA8
1,28,480
7.5
10
Frame
12
Excise duty including cess will be charged as applicable at the time of dispatch
MHLP 1A
R e v i s i o n - 4
Output
Frame
13
Output
Frame
MH71ZCA4
10,000
MH80ZAA6
11,780
MH80ZAA4
11,120
MH80ZBA6
11,780
MH80ZBA4
10,950
MH90SAA6
12,640
MH80ZCA4
11,730
MH90LBA6
14,630
MH90SAA4
12,260
MH100LAA6
19,110
MH90LBA4
13,400
MH100LBA6
19,894
MH90LDA4
13,875
MH112MAA6
22,730
MH100LAA4
18,070
MH112MBA6
24,979
MH100LBA4
18,430
MH132SZA6
33,450
MH100LCA4
18,480
MH132MYA6
37,230
MH112MAA4
22,650
MH132MZA6
38,691
MH112MBA4
24,745
MH132MTA6
38,945
MH132SZA4
31,200
MH160MZA6
60,100
MH132MZA4
36,460
MH160LYA6
70,990
MH132MRA4
38,155
MH160LZA6
74,213
MH160MXA4
56,810
MH160LXA4
72,390
Output
Frame
Excise duty including cess will be charged as applicable at the time of dispatch
MH90SAA8
12,970
Note:
MH90LBA8
14,620
MH100LAA8
17,590
pages 14 to 17
MH100LBA8
22,137
MH112MAA8
24,730
MH132SZA8
32,820
MH132MZA8
51,470
MH160MYA8
63,070
MH160MZA8
63,612
MH160LZA8
82,110
MHLP 1A
R e v i s i o n - 4
71ZCA4
80ZAA4
80ZBA4
80ZCA4
90SAA4
90LBA4
90LDA4
100LAA4
100LBA4
100LCA4
112MAA4
112MBA4
132SZA4
132MZA4
132MRA4
160MXA4
160LXA4
60 Starts / hour
90 Starts / hour
Motor GD2
25% CDF
40% CDF 60% CDF 25% CDF 40% CDF 60% CDF KGm2
KW
KW
KW
KW
KW
x103
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.7
3.7
5.5
5.5
7.5
9.3
11
15
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.7
3.7
5.5
5.5
7.5
9.3
11
15
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.3
3.7
5
5.5
7.5
9.3
11
15
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.7
3.7
5.5
5.5
7.5
9.3
11
15
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.7
3.7
5.5
5.5
7.5
9.3
11
15
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.3
3.7
5
5.5
7.5
8.5
9.9
15
3.92
6.32
8
9.64
10
12.52
16.2
18.4
22.32
24.2
48.8
60.8
88
120
148.8
324.8
422.8
150 Starts / hour 300 Starts / hour
Motor GD2
Frame
25% CDF
40% CDF 60% CDF 25% CDF 40% CDF 60% CDF KGm2
KW
KW
KW
KW
KW
KW
x103
1
1
1
1
1
2
2
2
3
4
3.7
5.5
5.5
7.5
9.3
11
15
0.55
0.55
0.75
1.1
1.1
1.5
2.2
2.2
3
3.3
3.7
5.5
5.5
7.5
8.5
11
15
0.5
0.55
0.75
1
1.1
1.5
2.2
2.2
3
3
3.7
4.5
5.5
7.5
8
9.3
13.5
0.5
0.55
0.67
1
1.1
1.5
2.2
2.2
2.8
3
3.7
4.5
5.5
7.5
7.7
8
13.5
0.45
0.5
0.6
1
1.1
1.5
2
2.2
2.8
3
3.3
4
5
7
7.2
7.5
11
0.4
0.45
0.6
0.8
1
1.3
2
2
2.5
2.5
3
3.5
4
6
6.8
7
9.3
71ZCA4
80ZAA4
80ZBA4
80ZCA4
90SAA4
90LBA4
90LDA4
100LAA4
100LBA4
100LCA4
112MAA4
112MBA4
132SZA4
132MZA4
132MRA4
160MXA4
160LXA4
Note:
1. Load GD2 value should not be more than motor GD2 value.
2. All motors suitable for an Ambient Temperature of 450C.
3.92
6.32
8
9.64
10
12.52
16.2
18.4
22.32
24.2
48.8
60.8
88
120
148.8
324.8
422.8
14
MHLP 1A
R e v i s i o n - 4
15
80ZAA6
80ZBA6
90SAA6
90LBA6
100LAA6
100LBA6
112MAA6
112MBA6
132SZA6
132MYA6
132MZA6
132MTA6
160MZA6
160LYA6
160LZA6
60 Starts / hour
90 Starts / hour
Motor GD2
25% CDF
40% CDF 60% CDF 25% CDF 40% CDF 60% CDF KGm2
KW
KW
KW
KW
KW
x103
0
1
1
1
2
2
2
3
3
4
5.5
7.5
7.5
9.3
11
0.37
0.55
0.75
1.1
1.5
1.8
2.2
3
3
3.7
5.5
7.5
7.5
9.3
11
0.37
0.55
0.75
1.1
1.5
1.8
2.2
3
3
3.7
5.5
7
7
9.3
11
0.37
0.55
0.75
1.1
1.5
1.8
2.2
3
3
3.7
5.5
7.5
7.5
9.3
11
0.37
0.55
0.75
1.1
1.5
1.8
2.2
3
3
3.7
5.5
7
7
9.3
11
0.37
0.55
0.75
1.1
1.5
1.8
2.2
2.7
3
3.7
5.5
6.5
6.5
9.3
11
7.88
9.88
12.72
19.12
26.92
37.72
56.72
74.8
94
118
149.2
216.4
324.8
422.8
422.8
150 Starts / hour 300 Starts / hour
Motor GD2
Frame
25% CDF
40% CDF 60% CDF 25% CDF 40% CDF 60% CDF KGm2
KW
KW
KW
KW
KW
KW
x103
80ZAA6
80ZBA6
90SAA6
90LBA6
100LAA6
100LBA6
112MAA6
112MBA6
132SZA6
132MYA6
132MZA6
132MTA6
160MZA6
160LYA6
160LZA6
0
1
1
1
2
2
2
3
3
3.7
5.5
7.5
5.8
9.3
11
0.37
0.55
0.75
1.1
1.5
1.8
2.2
3
3
3.7
5.5
7
5.3
9.3
11
0.33
0.5
0.7
0.9
1.3
1.6
2
2.7
2.7
3.3
5
6.3
5
9.3
9.8
0.33
0.5
0.7
0.9
1.3
1.8
2
2.7
2.7
3.3
5
6.5
-
9.3
9.8
0.33
0.5
0.7
0.9
1.1
1.5
2
2.2
2.7
3.3
5
6
-
8.2
8.5
0.3
0.45
0.65
0.8
1.1
1.3
1.8
2
2.2
3
4.5
5.5
-
7.8
8
7.88
9.88
12.72
19.12
26.92
37.72
56.72
74.8
94
118
149.2
216.4
324.8
422.8
422.8
Note:
1. Load GD2 value should not be more than motor GD2 value.
2. All motors suitable for an Ambient Temperature of 450C.
MHLP 1A
R e v i s i o n - 4
60 Starts / hour
90 Starts / hour
Motor GD2
25% CDF
40% CDF 60% CDF 25% CDF 40% CDF 60% CDF KGm2
KW
KW
KW
KW
KW
KW
x103
90SAA8
90LBA8
100LAA8
100LBA8
112MAA8
132SZA8
132MZA8
0.37
0.37
0.37
0.37
0.37
12.72
0.55
0.55
0.55
0.55
0.55
19.12
0.75
0.75
0.75
0.75
0.68
26.88
1.1
1.1
1.1
1.1
63.72
1.5
1.5
1.5
1.5
1.2
66.8
2.2
2.2
2.2
2.2
2.2
118
150.8
160MYA8
3.7
3.7
3.7
3.7
3.3
358
160MZA8
5.5
5.5
5.5
5.5
478
160LZA8
7.5
7.5
7.5
7.5
600.8
150 Starts / hour 300 Starts / hour
Motor GD2
Frame
25% CDF
40% CDF 60% CDF 25% CDF 40% CDF 60% CDF KGm2
KW
KW
KW
KW
KW
KW
x103
90SAA8
0.37
0.37
0.37
0.37
0.37
0.33
12.72
90LBA8
0.55
0.5
0.55
0.5
0.45
19.12
100LAA8
0.75
0.66
0.68
0.66
0.58
26.88
100LBA8
1.1
0.8
0.7
63.72
112MAA8
1.5
1.2
1.5
1.2
66.8
132SZA8
2.2
1.8
1.5
118
132MZA8
2.6
2.8
2.2
1.8
150.8
160MYA8
3.3
2.5
358
160MZA8
4.5
3.5
478
160LZA8
6.5
5.5
600.8
Note: 1. Load GD2 value should not be more than motor GD2 value. 2. All motors suitable for an Ambient Temperature of 45 deg. C.