Вы находитесь на странице: 1из 2

Programmable Controller MDA 5.

xxxx
Digital measuring instruments offering control functions and limit value indication.

Survey
The MDA 5.xxxx instruments are switching microprocessor-based display units for analogue signals, providing control inputs and an interface option. The apparatus has been developed particularly for use as process control units for tasks where - simple indication does no longer meet the requirements which can only be fulfilled with the help of additional wiring or switching, - where expensive process guiding systems are not appropriate in terms of price. By an integration of several functions and displays in one unit, expensive second equipment is often not required. As this apparatus has been developed and is being produced in our own factory, we can provide quick and low priced adaptation to the most different tasks.

Technical data
Voltage supply

(general) 90 - 265 V AC/DC overvoltage category III contamination level 2 10 VA protection class II connections/casing > 10 MOhm (at 500 VDC) acc.to EN 61010-1 (General safety requirements) acc.to EN 61000-6-2 (Generic Immunity Standard industrial environment) acc.to EN 61000-6-3 (Generic Emission standard
residential commercial and light industry)

Power consumption max. Set-up of apparatus Insulation resistance Safety Resistance to interference

Possibilities of adaptation:
Measuring inputs
The measuring input may be realized for electric current, voltage, resistance, PT 100, pulses or frequencies, respectively.

Emission of interference

Control inputs
2 control inputs. Functions e.g. as release, saving, switch-over, or acknowledgement input. Output sensor supply

24 VDC +/- 5% Imax 50 mA

Ambient conditions
Operating temperature Storage temperature Humidity Displays Height of digits Casing (acc.to DIN 43700) Size (WxHxD) Control panel cut-out Depth of installation Protection type Front of casing Connections 0...+ 50 C -20...+70 C 30...85% relative humidity 3 x 4 digit 7 seg. LED (red) 1 x 14.2 mm / 2 x 2.8 mm 96 x 48 NORYL black 96 x 48 x 96 mm 90 x 43 mm 96 mm EN 60 529 IP 53 IP 00

Interface
For data transfer to routing computers, PCs, large displays, automatic lettering units, printers, etc. Executions e.g. as V24 (RS232), RS 485.
03.2005 Errors excepted. Subject to alteration without notice.

Switching outputs
2 outputs designed as relays, electronic performance output, REED relays, opto couplers, or up to 4 PNP exits are possible. Functions e.g. as limit value switches, pretuned alarm, wire rupture, overload signal, switch-over or acknowledgement exit.

Programme
Scaling, computing, comparing, linking, saving, etc.

Mess- u. Regeltechnik GmbH, 32046 Herford, Germany Tel. (0 52 21) 98 29 - 0

K 15-10.010

Programmable Controller MDA 5.xxxx

Pin configuration:
1 2 3 4 5 + measuring input -24VDC -24VDC +24VDC (+ sensor 1) (- sensor 1) (- sensor supply) (+ sensor supply)

7 Reference potential (- control input) 8 Control input 1 10-24 VDC 9 Control input 2 10-24 VDC

Technical data
MDA)

(dependent upon the type of

A L1 Mains connection (90-265 V AC/DC) B N Mains connection D Relay 1 E Relay 1 F Relay 1 G Relay 2 H Relay 2 I Relay 2 (common contact) (opener) (closer) (common contact) (opener) (closer)

Signal input

0/4 - 20 mA

Input resistance 50 Ohm measuring rate 0.1sec Overload 1.5 fold TK<100 ppm/K Linearity between the supporting points +(0.1%+1digit) after about 15 min. working time

Signal input DC

Input resistance Overload 1.5 fold TK<100 ppm/K Linearity between the supporting points (0.1%+1digit) after about 15 min. working time

0 - 1 V, 0 -10 V >100 k measuring rate 0.1sec

Wiring examples:
Sensor 0/4 - 20 mA (3 Leiter)

Signal input
Measuring current Overload Measuring precision

<1mA measuring rate 0.1sec 1.5 fold TK<100 ppm/K (0.1%+1digit) of the final value after about 15 min. working time optocoupler 24 VDC 2k4 Ohm integrated >2.5kV

0 - 1000 , 0 - 10 k, 0 - 100 k

Control input
Control voltage Pre-resistance Insulation voltage

90 - 265 V AC / DC

Relais Grenzw. 1

Relais Grenzw. 2

Sensor 0-1 V

Exit optocoupler
Uc max 70 VDC If 10 mA Insulation voltage >5kV Transmission ratio 63% 24 VDC load Rl min. 1 kOhm not galvanically separated from the measuring input

90 - 265 V AC / DC

Relais Grenzw. 1

Relais Grenzw. 2

Output PNP
Separation K 15-10.010 R

03.2000 Errors excepted. Subject to alteration without notice.

Output relay 2 potential free rel.switch-over contacts Valuation voltage (relay contact to mains) 250 V ~ max. Load carrying capacity min.100mA(5V) max. 230VAC 1750VA Nominal load 230 V AC, 3A Electrical service life 10E5 switching operations (resistive load) Mechanical service life 10E7 switching operations