Вы находитесь на странице: 1из 33

1

3 3

Installation Manual for Jincheng Software

1. Requirements for the computer


1) Custom configuration: Main board: the video card should be separated CPU: 2.8GHz Memory: 1.0 GB / DDR 400 Mhz Hard disk: 80 GB /7200 RPM Video card: special video card with double DVI interfaces Display: 17--- 12801024 pixels Image files can be read and processed by inputting devices such as scanner, flash memory and Zip driver on your PC.

2) System: Windows XP Professional.

3 3

2. Software Installing & Display Card Setting


2.1 Software Install The new software is copying version. Copy New Version V1.19, jcLcoscfg.dat and 6inch_repair.bmp to PC from CD. Note: Put jcLcoscfg.dat into the root directory of exposure software and 6inch_repair.bmp into the file: Mask.

2.2 Display Card Setting The screen is dual-view (Extend the Windows desktop to this monitor). Monitor one is 1280*1024, and monitor two is 1280*768. The quality of color is 32 bits. Refresh frequency of screen is 60 Hz. It shows as below:

3 3

3 3

3. Software Using
Click JCExposal.exe. It shows as below:

3.1 System Setting Click System Setting on the purpose of choosing processing channel and type of the machine. This part is used to rectify most parameters for Digital Transducer. It shows as below:

3 3

3.1.1 Machine Setting Generally, as long as you choose the type of your machine in the list, the system will automatically load the default values matching your machine. You do not have to change any parameters, but you might have to when a modification is done in the analog machine ex: shutter or other connections done.

3 3

Remarks: 1 Choose the type of your machine and

the system will load the default parameters matching your machine. 2 It is used to check if the connection of the signal

cables is good before printing each time. 3 time. 4 time. 5 Different machines offer different shutter signals. If Check the status of the shutter before printing each Check the status of the shutter before printing each

this is chosen, it shows that the signal of shutter open, provided by the machine, is high-tension. Contrarily, it is low-tension. 6 If the pulse signal is offered by the machine, you have

to choose this item. Under any circumstance, Item 5 (High Dap) only checks pulse signal as long as you choose Pulse Check. 7 It is used to see if the machine is checking the

automatic size signal or not.

3 3

8 9 transducer. 10 image. 11 12

It is used to see if it need postpone the scanning time. Choose it according to the type of the digital

It is used to make the outputting pictures to be mirror

It is used to see if it need adjust the gray board. The system will choose this item automatically

according to different types of the digital transducer. 13 It is used to choose the mode of exposure key. If

choose this, it shows that the mode of exposure key is twice or more. If do not choose, it shows that the mode of the exposure key is once. 14 It is used to set the function key, whether you

will start the function key 2, 3. 15 Command waiting. If the waiting time

is over your setting time, the system shows it is wrong. Its default value: 15000 (10001 sec.) This time has not to be shorter than the longest exposure time. 16 machine starting running. 17 Time for checking the shutter once. Time from pressing the key to the

3 3

3.1.2 Screen Setting It is used to set the size, refresh rate and BPP of the pictures feeding from video card to digital transducer. Note: do not modify this part.

3.1.3 ID Photo Setting It is used to set the size of ID photos.

3.1.4 Lens Setting It is used to change the parameters of the lens and paper.

3 3

1 2 3 4.

Used to select the lens size. Used to select the paper size. Used to select the type of the paper.

Red, Green and Blue channel exposure time. 5 different paper and lens size. 3.1.5 Paper Channel It is used to adjust R, G and B exposure time. Show default values according to

Red Time, Green Time and Blue Time show the exposure time of each channel respectively. Their unit is ms (microsecond). Density: adjust the collective exposure time.

1 0

3 3

Width: paper width. 3.1.6 Index Setting It is used to set parameters of the company information. If needed, company information can be showed on the picture.

Symbol: used to set the path of Symbol showing on the right top of pictures. 3.1.7 Size Setting It is used to adjust sizes of output pictures and to set default values.

3.1.8 Serial Port Setting The following is the default parameters:

1 1

3 3

3.1.9 Led Control It is used to test working condition and focusing of the light source.

3.1.10 Paper Dash Out Setting

At present, this function is not available. No need to set.

1 2

3 3

3.1.11 Mini Setting

This part is used to set parameters for Jincheng 0812 & 1015 Minilabs. If tick this item, it shows to use minilab channel to make exposure and Machine Setting is no use. It shows to use 0812 channel. It shows to use 1015 channel. Paper Length: How long is the paper cut? Center Length: The distance from the magazine to the center of the image. Send Length: The distance from the center of the image to the lift. Motor: The power of the motor. It is only used for 0812. Supply Area: It equals the length the width of the picture. When processing area reaches to a certain parameter, the machine automatically replenish chemical once. Cleft Time(s): Time of assorting timer. Cut Paper: Sending signal to cut paper. Send Paper: Sending signal to send paper. Supply Water: Sending signal to replenish chemical.

1 3

3 3

Uninstall Paper: Rewinding paper Cleft: Sorting After finishing setting, click 3.2 Color Revising It is mainly used to adjust the output color of the digital transducer. Digital Transducer has enough space to save the Gammas of Red, Green, Blue channel. You need download these Gammas into the digital transducer at first. Through this function, you can easily to do it. to save your results.

3.2.1 Paper Channel Selecting It is used to select paper channel. Different papers have different sensitizing parameters. In order to get good reverting, you have to

1 4

3 3

choose your own paper mode because different paper needs different Gamma.

3.2.2 Gamma Control

Downloading values: 1~1213. Each digital transducer has its own parameters, so downloading values are different. We offer downloading default parameters for each digital transducer.

Gamma Value: not in use Min Red: minimum Gamma value of red light Max Red: maximum Gamma value of red light Min Green: minimum Gamma value of green light Max Green: maximum Gamma value of green light

1 5

3 3

Min Blue: minimum Gamma value of blue light Max Blue: maximum Gamma value of blue light When you tick and click , it shows that

you confirm to download the Gamma. 3.2.3 Information

When you run the digital transducer, it will offer you sending and receiving signal so that you can see if the machine works normally or not. The position of the cursor. 3.2.4 Curve Control

1 6

3 3

3.2.5 Density Loading

Ticking it shows to start to load density, using densitometer. This item is no use for end-users.

1 7

3 3

3.2.6 Gamma Downloading Click to download Gamma.

3.3 Print Management Click Print Management.

3.3.1 Remarks Pressing right button of the mouse is decreasing and left button is increasing.

1 8

3 3

Cyan

Magenta

Yellow

Density

Contrast

Saturation

Sharpness

Gamma

Zoom in/out

1 9

3 3

Print quantity

Numerical increment 3.3.2 Prints Making 3.3.2.1 Custom Printing 1. Click to load pictures from PC.

2. Select pictures you want to print and then click

to open them.

2 0

3 3

2 1

3 3

Click Print Page to print pictures on current page. Click Print All to print all loaded pictures. Click Clear to clear all loaded pictures. Dblclick any one picture to enter into Adjust Image. It shows as below:

2 2

3 3

3. After your adjustment, click

or

to print.

2 3

3 3

3.3.2.2 ID Photo and Index Print 1. ID Photo Click ID in Adjust Image. It shows as below:

Take 1inchx4-2inchx2 for an example: A. Choose 1inchx4-2inchx2 in Template box.

2 4

3 3

B. Click rectangles to make them turn red. Note: Red rectangles are available.

2 5

3 3

2 6

3 3

C. Select Image (Press

to adjust image.)

D. Dblclick selected part.

2 7

3 3

E. Repeat steps of B, C and D till all rectangles are filled with images.

2 8

3 3

F. Click Create.

2 9

3 3

Note: the size of rectangles can be modified in System Setting. Please refer to 3.1.3.

2. Index Print A. Click to load pictures.

3 0

3 3

B. Choose pictures you want and then click Print.

to create Index

3 1

3 3

After creating Index Print, Index Print file Index0.bmp appears on the screen. It shows as below. Finally, load Index0.bmp to print.

3 2

3 3

3. ID Photo & Index Print After creation ID photo & index print, make them print like custom print. Please refer to 3.3.2.1.

3.4 Color Management Click Color management. Ticking Color Management is in use. shows

3 3

3 3

Вам также может понравиться