Академический Документы
Профессиональный Документы
Культура Документы
Corning
Cable Systems
Copyright © 2005
All rights reserved. This publication must not be reproduced or copied in any
way whatsoever without the express consent in writing of Corning Cable
Systems GmbH & Co. KG. All Corning Cable Systems products described in
this catalog are subject to availability and technical modification. Corning
Cable Systems GmbH & Co. KG reserves the right to improve, enhance or
otherwise modify Corning Cable Systems product without prior notification,
including and in particular technical data and other information about such
products. There is no legal obligation to supply a specific product to a precise
specification until a binding order is accepted by Corning Cable Systems
GmbH & Co. KG.
1 Introduction 3
Introduction
2 FutureCom™ F System 13
FutureCom F
3 FutureCom 10 TEN System 41
FutureCom 10TEN
4 FutureCom E System 55
FutureCom E
5 FutureCom D System 81
FutureCom D
6 FutureCom UE System 101
FutureCom UD FutureCom UE
7 FutureCom UD System 115
8 Hardware 127
Hardware
9 Telephone / ISDN Products 165
1 Introduction 3
Introduction
1.1. Corning - A Reliable Partner 4
FutureCom F
1.3. Corning Cable Systems Global Locations 6
FutureCom 10TEN
1.5. System Description
FutureCom E
FutureCom D
FutureCom UD FutureCom UE
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
Corning Incorporated is a diversified technology company Corning’s own complete system for structured cabling, on
with a proud history of developing breakthrough technolo- the basis of copper cable, followed in 1990. Since then, Corn-
gies that significantly improve people’s lives. We have been ing has always been a market leader and the technology
changing the world through innovation for more than 150 leader for cabling systems. In 1995, for the first time in the
years, integrating scientific discovery with market need. We world, Corning started using 600 MHz technology for sym-
focus on high-impact growth opportunities in the telecom- metrical copper cabling systems.
munications, flat panel display, environmental, life sciences
and semiconductor industries. Today, with LANscape® FutureCom™, Corning offers a com-
plete system of copper components with bandwidths of 100
Corning is a reliable partner that meets the communication to 1500 MHz and the experience of installing more than
requirements of its customers all over the world with cost- 15 million ports. This can also be combined with modular
effective solutions. fiber optic hardware and FutureCom™ cable components.
LANscape - the combination of FutureCom™ copper and
In 2000 Corning grouped all its cable, hardware and equip- fiber optic products - thus offers the optimal solution for
ment businesses into the Corning Cable Systems division. every network.
Corning Cable Systems now comprises the former Siecor
Corporation, the communication cables business from BICC Our quality and environmental management systems are
(Corning Cables), Siemens’ former Communication Cables certified to DIN EN ISO 9001 and ISO 14001. Our global pres-
division and RXS Kabelgarnituren. Norddeutsche Seekabel- ence is your gain because, wherever you are, Corning is close
werke (NSW) also belongs to Corning Incorporated and is at hand.
continuing to operate as a separate company.
5
Further Special Industrial Flex Wire Cable Telephone /
Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction
Information Cable Cable for Patch Cord ISDN Products
Corning Cable Systems Global
Cable and Hardware Businesses
Hagen,
Whiston, Great Britain Germany
Nordenham,
Germany
Derby, Great Britain Berlin,
Germany
Aberdeen,
Great Britain Neustadt,
Germany
Deeside,
Wales
Lodz,
Poland
Headquarter, Favières, France
Hickory NC, Munich,
Germany
USA Madrid,
Winston-Salem, Spain Turin, Italy
NC, USA
Keller, TX, USA
Rio Grande,
Puerto Rico
Boca Raton,
FL, USA
Introduction
Corning Cable Systems EMEA Headquarters is located in
Berlin, Germany.
FutureCom F
FutureCom 10TEN
FutureCom E
Moscow,
Russia
FutureCom D
Gebze, Türkei
FutureCom UD FutureCom UE
Amman, Tokyo, Japan
Jordan Shanghai,
China
Bangkok,
Thailand Makati City,
Phillipines
Kuala Lumpur,
Malaysia
Singapore,
Hardware
Singapore
Clayton,
Australia
Industrial
Cable
Special
Cable
Information
Further
The requirements of future-proof and flexible structured cabling are largely determined by three fundamental cabling
standards addressing specific geographic regions:
Standard Description
North America TIA/EIA 568 B. 1 (2001) / B.2 1 (2001) Commercial Building Telecommunications
Cabling Standard
World ISO/IEC 11801 Edition 2002 Cabling Standard, Generic Cabling for
Customer Premises
The TIA/EIA is not a standard as such, but an industry specification in the North American market. It also contains
requirements regarding the transmission characteristics of cabling and components that differ from those of the EN or ISO/
IEC. It has its origins in the specification of unshielded copper components.
1500 m 500 m 90 m
Building cabling can utilize cabling with both symmetrical copper cables and components and fiber optic cables and
components. In the primary area, only fiber optic cables and components are used.
Introduction
FutureCom F
Campus Backbone Horizontal Subsystem
Campus cabling (backbone) links the individual buildings in In the horizontal subsystem, mainly copper cable is used.
FutureCom 10TEN
one location with each other. The campus distributor forms The cabling is installed in a star shape radiating out from
the center of primary cabling. Due to the relatively long the horizontal distributor to the individual connection
transmission paths, only fiber optic cabling is worth consid- boxes. The distance, however, should not exceed 90 m, since
ering. Corning offers a fiber optic modular cabling solution the cabling would then no longer comply with the standard.
FutureCom E
which can be combined with copper-component cabling sys-
tems. For the campus environment, mainly single-mode An additional option in the horizontal area is “fiber to the
fiber cable is used, which distinguishes itself by its low at- desk” (FTTD), i.e. fiber optic cabling to the workstation. This
FutureCom D
tenuation and high bandwidth. A further argument for fiber is used for high bandwidth or long distance centralized
optic cable in this area is its electromagnetic insensitivity. cabling applications.
Building Backbone
FutureCom UD FutureCom UE
The connection between the building distributor and the
various horizontal distributors is designated as the second-
ary area. It represents the backbone of the building. The ca-
bling of the vertical area can be carried out with both sym-
metrical copper cables and fiber optic cables. “High-end”
copper data cable (bandwidths up to 1500 MHz), such as
those you can find in the Corning FutureCom™ product
Hardware
range, can also be used in the secondary area for lengths up
to 100 m.
FutureCom F
FutureCom Floor Distributors
(see pages 144-151)
FutureCom 10TEN
FutureCom E
Campus Backbone – Building Distributor:
19“ Patch Panels
FutureCom D
(see pages 152-156 or the LANscapeFiber Optic
Catalog, EUR-220-EN)
FutureCom UD FutureCom UE
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Campus Backbone – Backbone Cabling:
Fiber Optic Cables
(see the LANscape Fiber Optic Catalog,
EUR-220-EN)
Industrial
Cable
FutureCom 19“ Distribution Panels Fiber Optic Cable or FutureCom S/FTP, F/FTP, SF/UTP, F/UTP
or 19“ Patch Panels (see the LANscape Fiber Optic Catalog or system chapters
(see pages 152-156 or the LANscape® Fiber Optic in this catalog)
Information
Further
Catalog, EUR-220-EN)
2 FutureCom F
Introduction
2.1. System Descriptions & Data 14
2.2. Certificates 17
FutureCom F
2.3. Cable
FutureCom 10TEN
2.4. Connecting Hardware
FutureCom E
2.4.3. S1200 Connectors 23
2.4.4. Tools 25
FutureCom D
2.5. Hardware
FutureCom UD FutureCom UE
2.5.2. Floor Box Solutions 29
Hardware
2.6.2. Cat. 6 Patch Cords 34
FutureCom F (2002) is Corning’s high-end system solution for symmetrical copper cabling. It satisfies all the requirements of
the current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards for Class F links and Category 7 for the components. The
FutureCom F System is part of the Pretium™ Solutions family. Pretium Solutions is Corning Cable Systems’ high preformance
solution set for fiber and copper premises networks.
Face Plate
80x80 mm
“DELTAprofil”,
WAXWSE-00001-C001
and S1200 Frame Set,
for two
S1200 Modules, Cat.7, SF/UTP flex/26, gray,
inclined, 1xS1200/2 and
CAXFSE-S0201-C001 1xRJ45 connector,
2 pairs,
FutureCom for 10/100Base-T
S/FTP 1200/22 CCAFGD-D1024-A030-C1
CCXFCB-L0047-C001-L7
The highest level of system performance up to 10GBase-T for The FutureCom F system offers technical transmission
the complete link is achieved through the utilization of possibilities similar to those of optical cabling systems and
high-quality Category 7 cables, connectors and patch cords. permits multimedia applications, such as TV transmission. In
The resulting performance and future security guaranty the addition, it enables the optimal utilization of cabling
maximum level of investment protection for cabling. through the use of 2-pair patch cords (cable sharing).
FutureCom F cabling conforms with the standards and is The performance of the FutureCom F cabling system has
outstandingly well suited for all recognized standardized been certified by an independent testing body (see certifi-
voice and data transmission procedures. This applies to ana- cate). Of course, all EMC values standardized in Europe are
log voice transmission, ISDN, Token Ring, Ethernet (10-Base- observed.
T), Fast Ethernet (100Base-TX), Gigabit Ethernet, 10 Gigabit
Ethernet, 100Base-VG and ATM.
Introduction
Frequency in MHz 1 10 20 62.5 100 155.5 250 600 850 1000 1200
Max. attenuation in dB* 4.0 20.8 33.8 54.6
Attenuation in dB (typ. FutureCom™ F values) 1.9 5.3 7.5 13.4 17.1 21.4 27.5 43.5 52.3 57.6 69.2
– – – – – – –
FutureCom F
Min. NEXT in dB* 65.0 62.9 – 56.9 51.2
NEXT in dB (typ. FutureCom F values) 104.0 99.0 96.0 89.0 86.0 82.0 78.0 68.0 60.0 58.0 53.0
– – – – – –
FutureCom 10TEN
ACR in dB (typ. FutureCom F values) 102.1 93.7 88.5 75.6 68.9 60.6 50.5 24.5 7.7 0.4
– – – – –3.4 – – –
ELFEXT in dB (typ. FutureCom F values) 103.0 95.0 91.0 83.0 79.0 74.0 68.0 54.0 45.0 41.0 30.0
– – – – – –
FutureCom E
Return loss in dB (typ. FutureCom F values) 21.0 21.0 21.0 21.0 21.0 21.0 19.0 16.0 15.0 14.0 10.0
– – – – – – –
The system values cited only apply to the use of original FutureCom F products. Derived values, such as PSACR, PSNEXT,
FutureCom D
PSELFEXT, are in observance of the standard values, but are not shown.
FutureCom UD FutureCom UE
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom F values)
min. NEXT in dB
According to standard
Hardware
max. Attenuation in dB
According to standard
Attenuation in dB
Frequency in MHz
Industrial
Cable
Special
Cable
Information
Further
ELFEXT in dB
(typ. FutureCom™ F values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom F values)
Frequency in MHz
Application
Braided shield
The FutureCom™ S/FTP 1500/22 and S/FTP 1200/22 cables
Halogen-free sheath,
flame retardant are designed for applications up to 1500/1200 MHz. Their
transmission characteristics significantly exceed the require-
Twisted pair ments defined by today’s Category 7 specifications
(EN50288).
Foil shielding (PiMF)
4 shielded pairs FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
PE foam-skin insulation
required for applications above 1 Gigabit Ethernet. The possi-
Copper conductor bility of using the cable up to the GHz area enables the
AWG 22 highest possible transmission rates for multimedia applica-
tions such as TV transmission, in future-proof networks.
Introduction
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/– 20 %
Impedance Zo at 1 - 100 MHz 100 V +/– 15 %
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/– 18 %
Impedance Zo at 251 - 600 MHz 100 V +/– 25 %
Surface transfer impedance <2 m V/m at 10 MHz
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
FutureCom 10TEN
Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz
Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz
Propagation velocity 0.77 x c for S/FTP 1200
at >10 MHz (NVP x c) 0.76 x c for S/FTP 1500
FutureCom E
Propagation delay >_ 10 MHz 4.2 ns/m
Delay skew 6 ns/100 m
FutureCom D
Electrical Characteristics (at 20°C) for S/FTP 1500/22
Frequency in MHz 1 10 16 31.25 62.5 100 300 600 1000 1200 1500
Attenuation in dB/100m * 2.0 5.7 7.2 10.1 14.5 18.5 33.3 48.9
FutureCom UD FutureCom UE
Typical values dB/100m 1.7 5.3 6.8 9.7 13.8 17.5 30.8 44.0 57.8 63.6 72.0
– – –
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100 m >105.0 >105.0 >105.0 >105.0 >105.0 >105.0 103.0 95.0 85.0 80.0 75.0
– – –
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Typical values in dB at 100m 102.0 102.0 102.0 102.0 102.0 102.0 100.0 92.0 82.0 77.0 72.0
ELFEXT in dB at 100 m * 80.0 74.0 69.9 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 96.0 96.0 96.0 93.0 88.0 82.0 68.0 55.0 37.0 31.0 24.0
– – –
PSELFEXT in dB at 100 m * 77.0 71.0 66.9 61.1 55.1 51.0 41.5 35.4
Hardware
Typical values in dB at 100m 93.0 93.0 93.0 90.0 85.0 79.0 5.0 52.0 34.0 28.0 21.0
– – –
ACR in dB 103.3 99.7 98.2 95.3 91.2 87.5 72.2 51.0 27.2 16.4 3.0
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Industrial
Cable
Typical values in dB at 100m 103.0 103.0 103.0 103.0 103.0 103.0 103.0 100.0 93.0 83.0 78.0
ELFEXT in dB at 100 m * 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 96.0 96.0 96.0 93.0 93.0 88.0 82.0 70.0 55.0 40.0 35.0
– –
PSELFEXT in dB at 100 m * 77.0 71.0 66.9 65.0 61.1 55.1 51.0 41.5 35.4
Special
Cable
Typical values in dB at 100m 94.0 94.0 94.0 94.0 91.0 86.0 80.0 68.0 53.0 38.0 33.0
– –
ACR in dB 103.3 100.1 98.6 98.0 96.0 92.2 88.5 73.1 53.3 30.5 20.2
Information
* Standard: Requirements for 100 m installed Category 7 cable for Class F cabling sections (complies with EN 50288-4-1 and
Further
IEC 61156-7)
Ordering Information
Max.
Fire Load Halogen- Tensile Outer [ Weight Length
Type designation Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
Features
Introduction
Category 7+ Module
Up to 1200 MHz bandwith per pair
Dust protection flap to prevent exposure to contaminants
Wide range of installation options
FutureCom F
Few individual components
High-level component density
Individual shielding of the modules
FutureCom 10TEN
Individual components of the S1200 Module
FutureCom E
FutureCom D
S1200 Adapter
FutureCom UD FutureCom UE
side of the S1200 Module) enables the S1200 module to be
inserted into the module adapter. The S1200 adapter ex-
tends the application possibilities of the Cat. 7 module to
many components in the LANscape® product range, such as:
Patch panels
Frame sets
Floor box solutions
Hardware
S1200 Module with adapter for LANscape® interface
Features
Ordering Information
Units per
Order Number Description Delivery
CAXFSM-00100-C001 S1200 module, 1 x S1200, shielded, Cat. 7+, 1/1
for installation in LANscape patch panels,
outlets and floor box mounting plates
Blank Covers
Units per
Order Number Description Delivery
1 slot for installation in
FutureCom™ F S1200 patch panels,
outlets and floor box mounting plates
(S1200 direct assembly without module adapters)
CAXFSN-00101-C001 white, RAL 9010 10/1
CAXFSN-00108-C001 black, RAL 9005 10/1
Features
Introduction
Bandwidths up to 1200 MHz per pair
Quick and easy to install
IDC connection (IDC = Insulation Displacement Contacts)
High density, i.e. for each module the following connector
FutureCom F
combinations can be used:
– one 4-pair connector
– two 2-pair connectors
FutureCom 10TEN
– one 2-pair connector and two 1-pair connectors
– four 1-pair connectors
Shielded connectors are designed for the use with S/FTP
type cables
FutureCom E
Ordering Information
FutureCom D
S1200/4 Connector 4-pairs, shielded, Cat.7+
Units per
FutureCom UD FutureCom UE
Order Number Description Delivery
CAXFSS-00100-C001 S1200/4 Connector, shielded, Cat. 7+, 1/1
4-pair, for flex wire cables AWG 26
Hardware
CAXFSS-00100-C004 1200/4 Connector, shielded, Cat. 7+, 1/1
4-pair, for solid wire AWG 22 to 23,
Ordering Information
S1200/2 Connector, 2-pair, shielded, Cat. 7+
Units per
Order Number Description Delivery
CAXFSS-00100-C002 S1200/2 Connector, shielded, Cat.7+, 1/1
2-pair, for flex wire cable AWG 26
Introduction
Integrated knife for the removal of the jacket
Stripping option for the PiMF foils with a defined length
Management for arrangement or shaping of the individual
pairs (PiMF)
FutureCom F
Defined section length of the wires
Ordering Information
FutureCom 10TEN
Units per
FutureCom E
Order Number Description Delivery
CAXFSN-00000-C001 S1200 Tool, 1/1
for the assembly
of S1200 modules
FutureCom D
and S1200/4 or
S1200/2 connectors
FutureCom UD FutureCom UE
Parralel Pliers and Copper Conducting Tape
CAXCSN-00000-C008 Comfort Parallel Pliers, for the termination of 1/1
the IDC contacts on FutureCom™ S1200 modules
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Ordering Information
Units per
Order Number Description Delivery
CAXFSE-S0201-C001 S1200 Frame Set, inclined, 1/1
for 2 FutureCom™ S1200 modules,
including mounting frame
and 50x50 mm central plate with
designation window,
threaded, white RAL 9010
Units per
Order Number Description Delivery
Frame Set, inclined, projecting,
for 2 S1200 modules with module
adapters, including mounting frame
and 50x 50 mm central plate with
designation window
and dust protection flaps
WAXWSE-V0201-C001 white, RAL 9010 1/1
WAXWSE-V0202-C001 pearl white, RAL 1013 1/1
Introduction
Direct assembly of S1200 modules
Surface mount housing suitable for the face plates; see page 136.
FutureCom F
Ordering Information
FutureCom 10TEN
Units per
Order Number Description Delivery
WAXWSE-V0201-C002 Universal Housing, inclined, projecting, 1/1
FutureCom E
for face plate (147x87 mm and 87x87 mm)
for the direct integration of 2 S1200 modules,
central partition provided, white, RAL 9010
FutureCom D
FutureCom UD FutureCom UE
WAXWSE-00001-C005 Face Plate, 87x87 mm, 1/1
for one housing,
including two metric screws and
two withworth screws,
for frame assembly in installation outlets,
white, RAL 9010
(Suitable Surface Mount Housing
Hardware
WAXWSE-00001-C004; see page 136)
Ordering Information
Units per
Order Number Description Delivery
Frame Set, inclined, for 3 S1200 modules
with module adapters,
including mounting frame and triple housing
with designation window
and dust protection flaps,
also as 80x80 mm face plate
WAXWSE-V0301-C001 white, RAL 9010 1/1
WAXWSE-V0302-C001 pearl white, RAL 1013 1/1
Installation Option
Frame Set, inclined, for 6 S1200 modules with module
adapters, including mounting frame and two triple housings
with designation window and dust protection flaps, as well
as 151 x 80 mm face plate, white, RAL 9010:
WAXWSE-V0601-C001
Features
Introduction
Specially designed for the direct integration of S1200
modules
Stable metal construction, no additional installation
trough required
FutureCom F
Integrated cable strain relief that can be mounted
in various positions
No screwing required
FutureCom 10TEN
Integrated grounding bolt
Designation window with title strips
Ordering Information
FutureCom E
Units per
Order Number Description Delivery
FutureCom D
CAXFSU-00600-C001 Mounting Panel for Ackermann Floor Boxes 1/1
GES 2, GES 4, GES 4/10, GESR 4, GES 6,
GES 6/10, GESR 7/10 (outer) or GES 8/10,
for the installation
FutureCom UD FutureCom UE
of 6 FutureCom™ F S1200 modules,
with integrated cable strain relief
and six cable ties,
designation window, black
Hardware
GESR 7/10 (center), GES 9 or GESR 9, for
the installation
of 9 FutureCom F S1200 modules,
Ordering Information
Units per
Order Number Description Delivery
CAXFSU-00900-C002 Mounting Panel for Kleinhuis Floor Box 1/1
GR. II and GR. III (outside only),
for the installation
of 9 FutureCom™ F S1200 modules,
with integrated cable strain relief
and nine cable ties,
designation window, black
Installation Option
Mounting Panel for Kleinhuis Floor Boxes GR. II and GR. III
(only left or right position):
CAXFSU-00900-C002
Features
Introduction
Specially designed for the direct integration of S1200
modules
Integrated shielded transitional spring
Patch panel accessories, see page 156
FutureCom F
Ordering Information
FutureCom 10TEN
Units per
Order Number Description Delivery
FutureCom E
CAXFSV-02400-C001 S1200 Patch Panel 19“, shielded, Cat. 7+, 1/1
including 24 FutureCom™ F S1200 modules,
with integrated cable strain relief and shielded
transitional spring, 1 U, high-grade steel
FutureCom D
FutureCom UD FutureCom UE
CAXFSV-02400-C002 S1200 Patch Panel 19“, 1/1
for max. 24 FutureCom F S1200 modules,
with integrated cable strain relief and shielded
transitional spring, 1 U,
high-grade steel
Hardware
CAXFSV-01200-C001 S1200 Patch Panel 10“, 1/1
Features
Ordering Information
Units per
Order Number Description Delivery
WAXWSW-00008-C014 Consolidation Point Housing for max. 12 FutureCom F S1200 modules, 1/1
with strain relief for incoming data cables, patch cord strain relief and
dust protection flap for floor, wall and ceiling installation,
60 x 263 x 320 mm (HxWxD)
Description
Introduction
FutureCom F Category 7 patch cords are available in two or
four pair versions with foil and full braided shielding (S/FTP).
They are pre-terminated with shielded S1200 connectors on
both ends and are available in various lengths. The patch
FutureCom F
cords meet all the transmision property requirements for
Channel F (2002).
FutureCom 10TEN
Features
FutureCom E
S1200/4 connector pair fully configured and
application-neutral
S1200/4 connector pair for up to 10GBase-T applications
FutureCom D
S1200/2 connector pair fully configured on both sides
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics
FutureCom UD FutureCom UE
Ordering Information
Hardware
1 1
Description
Features
Ordering Information
CCAFGB - G 021 - A - C0
1 2
1 Select color.
1 = gray
2 = blue
3 = yellow
4 = green
5 = red
6 = black
2 Select length.
010 = 1 meter
015 = 1.5 meters
020 = 2 meters
030 = 3 meters
040 = 4 meters
050 = 5 meters
060 = 6 meters
080 = 8 meters
100 = 10 meters
150 = 15 meters
Description
Introduction
Application-neutral, Category 5 SF/UTP patch cords with four
pairs are pre-terminated with S1200/4 and RJ45 connectors.
The patch cords meet all the transmision property require-
ments for Channel D (2002) and Cat. 5 (2002).
FutureCom F
Features
FutureCom 10TEN
SF/UTP flex cable, specified up to 300 MHz
Pre-terminated with S1200/4 and RJ45 connectors
FutureCom E
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics
FutureCom D
4 Pair, AWG 26, Cat. 5 (2002)
Ordering Information
FutureCom UD FutureCom UE
CCAFGF - D 021 - A - C0
1 2
1 Select color.
Hardware
1 = gray
2 = blue
3 = yellow
4 = green
2 Select length.
010 = 1 meter
015 = 1.5 meters
020 = 2 meters
030 = 3 meters
Industrial
040 = 4 meters
Cable
050 = 5 meters
060 = 6 meters
080 = 8 meters
100 = 10 meters
Special
Cable
Information
Further
Description
Features
Ordering Information
For 10/100 Base-T Applications (Pins 1.2 - 3.6) For TR/ISDN and Analog Applications
(Pins 4.5 - 3.6)
CCAFGD - D 24 - A - C1 CCAFGD - D 24 - A - C1
1 2 1 2
Description
Introduction
FutureCom™ F U/UTP flex FRNC patch cords are pre-
terminated with S1200/1 or S1200/2 and RJ45 or RJ11/12
connectors for service specific applications.
FutureCom F
Features
FutureCom 10TEN
U/UTP flex cable, specified up to 100 MHz
Pre-terminated with S1200/1 or S1200/2 connectors
Pre-terminated with RJ11/12 or RJ45 connectors
FutureCom E
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
FRNC cable, unshielded
FutureCom D
FutureCom UD FutureCom UE
Ordering Information
CCAFFE - A6 -A - C0
1 2 3
Select application.
Hardware
1
24 = S1200/2 to RJ45
25 = S1200/2 to RJ11
27 = S1200/1 to RJ45 (Telephone)
28 = S1200/1 to RJ11 (Telephone)
34 = S1200/1 to S1200/1 (Neutral)
Industrial
Select length.
Cable
010 = 1 meter
015 = 1.5 meters
020 = 2 meters
Special
Cable
030 = 3 meters
040 = 4 meters
050 = 5 meters
060 = 6 meters
Information
080 = 8 meters
Further
100 = 10 meters
Features
Specifications
Insertion Attenuation Frequency Range
Back-to-back (75 V 100 V) < 2 dB 5...300 MHz
(100 V 75 V) < 3.5 dB 300...450 MHz
Return loss
Measured at the 75 V end < 19 dB 5...300 MHz
The 100 V end is terminated with a resistor of 100 V. < 12 dB 300...450 MHz
Surface transfer impedance
Rk [mV] < 20 mV 10 MHz
Ordering Information
Order Number Description Length
CCAFGB-I4054-A030-C0 FutureCom™ TV/CATV Patch Cord, 3m*
1 x S1200/1 and 1xTV connector (IEC60169-2),
FRNC sheath, green
Application
Introduction
The S1200 Solution Packages are factory pre-terminated cables. They are offered with
FutureCom™ S/FTP 1200/22 cables, and enable Plug & Play™ installation, significantly
reducing installation time. The assemblies are 100% factory tested, preventing instal-
lation faults on-site.
Ordering Information
FutureCom F
S1200 Solution Packages
FutureCom 10TEN
Order Number Description Length
Solution Package with S/FTP 1200/22
FutureCom E
data cable, 4 pairs, application neutral,
FRNC jacket, pre-terminated
with 2 S1200 Modules
CCAFCB-M2042-A100-C0 S1200 Solution Package S/STP1200/22 - 10 10 m
FutureCom D
CCAFCB-M2042-A150-C0 S1200 Solution Package S/STP1200/22 - 15 15 m
CCAFCB-M2042-A200-C0 S1200 Solution Package S/STP1200/22 - 20 20 m
CCAFCB-M2042-A250-C0 S1200 Solution Package S/STP1200/22 - 25 25 m
FutureCom UD FutureCom UE
CCAFCB-M2042-A300-C0 S1200 Solution Package S/STP1200/22 - 30 30 m
CCAFCB-M2042-A350-C0 S1200 Solution Package S/STP1200/22 - 35 35 m
CCAFCB-M2042-A400-C0 S1200 Solution Package S/STP1200/22 - 40 40 m
CCAFCB-M2042-A450-C0 S1200 Solution Package S/STP1200/22 - 45 45 m
CCAFCB-M2042-A500-C0 S1200 Solution Package S/STP1200/22 - 50 50 m
CCAFCB-M2042-A550-C0 S1200 Solution Package S/STP1200/22 - 55 55 m
CCAFCB-M2042-A600-C0 S1200 Solution Package S/STP1200/22 - 60 60 m
CCAFCB-M2042-A650-C0 S1200 Solution Package S/STP1200/22 - 65 65 m
Hardware
CCAFCB-M2042-A700-C0 S1200 Solution Package S/STP1200/22 - 70 70 m
CCAFCB-M2042-A750-C0 S1200 Solution Package S/STP1200/22 - 75 75 m
CCAFCB-M2042-A800-C0 S1200 Solution Package S/STP1200/22 - 80 80 m
CCAFCB-M2042-A850-C0 S1200 Solution Package S/STP1200/22 - 85 85 m
CCAFCB-M2058-A200-C0
Further
Applications
Ordering Information
Units per
Order Number Description Delivery
CCAFGB-G20ME-A020-C0 S1200 Test Adapter Cable, 2 m, 2/1
for Fluke DSP 4x00 (per pair)
Introduction
3.1. System Descriptions & Data 42
3.2. Certificate 45
FutureCom F
3.3. Cable 46
FutureCom 10TEN
3.4.1. S10TEN Module Overview 47
3.5. Hardware
FutureCom E
3.5.1. S10TEN Outlets 49
FutureCom D
3.6. Patch Cords
FutureCom UD FutureCom UE
3.6.2. Consolidation Point Patch Cords 51
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
Corning Cable Systems’ FutureCom™ 10 System has been especially developed to support 10 Gigabit Ethernet (10GBase-T)
TEN
over 100 meters. FutureCom 10 is the latest addition to Pretium™ Solutions, Corning Cable Systems’ high-performance
TEN
fiber and copper solutions for premises networks, and is fully compliant with the IEEE 802.3an (Draft 2.0) standard for
10 Gigabit Ethernet transmission. The current FutureCom 10 is especially designed for 10 Gigabit applications in riser and
TEN
horizontal environments, avoiding alien near-end and far-end cross talk (ANEXT, AFEXT), in order to warrant the higher
performance of cabling through immunity.
Face Plate
80x80 mm
“DELTAprofil”,
WAXWSE-00001-C001
and S10TEN outlet, S/FTP flex/26, gray,
2xRJ45, 2xRJ45 connectors,
10GBase-T, inclined 4 pairs, for up to
CAXTSD-S0201-C001 10 GBase-T
CCATGD-G1002-A020-C0
FutureCom
S/FTP900/23
CCXEDB-I0047-C001-L7
S10TEN Patch Panel 19“,
S10 Module,
TEN
for max. 24 S10TEN
1 x RJ45,shielded, modules,
10GBase-T with integrated cable
CAXTSM-00112-C001 strain relief, 1 U,
front panel of
high-grade steel
S/FTP flex/26, gray, WAXTSV-02400-C001
2xRJ45- connectors,
4 pairs, for up to
10GBase-T
CCATGB-G1002-A020-C0
A very high level of system performance is achieved for the It is suitable for all recognized standardized voice and data
link through the use of high-quality 10GBase-T connection transmission applications up to 10GBase-T.
technology. The quality of the components guarantees
maximum future security and reliability. The performance of the FutureCom 10TEN cabling system has
been certified by an independent testing body (see certifi-
Using all eight contacts in the RJ45 Connector as well as in cate). Of course, all standardized EMC threshold values in
the RJ45 Module, the cabling can be used universally and is Europe are observed.
application-independent.
Introduction
Frequency in MHz 1 10 20 62.5 100 155.5 200 250 500
Max. attenuation in dB according to standard * 4.0 21.7 35.9 53.4
Attenuation in dB (typ. FutureCom 10TEN values) 2.0 5.6 8.0 14.3 18.1 22.7 25.7 28.8 41.9
– – – – –
FutureCom F
Min. NEXT in dB according to standard * 65.0 39.9 33.1 22.0
NEXT in dB (typ. FutureCom 10 values) 89.4 85.3 75.0 63.6 57.9 53.3 50.7 47.9 37.6
– – – – –
TEN
FutureCom 10TEN
ACR in dB (typ. FutureCom 10 values) 88.1 78.5 66.6 49.5 40.1 31.3 25.8 20.2 -2.0
– – – – –
TEN
FutureCom E
Return loss in dB (typ. FutureCom 10TEN values) 33.9 32.7 30.7 32.4 32.1 31.3 30.3 26.5 22.1
– – – – –
The system values cited only apply to the use of original FutureCom 10TEN products. Derived values, such as PSACR, PSNEXT,
FutureCom D
PSELFEXT, are in observance of the standard values, but are not shown.
FutureCom UD FutureCom UE
Attenuation and
Near-end Crosstalk (NEXT)
NEXT in dB
(typ. FutureCom 10TEN values)
min. NEXT in dB
According to Standard
Hardware
max. Attenuation in dB
According to Standard
Frequency in MHz
Industrial
Cable
Special
Cable
Information
Further
ELFEXT in dB
(typ. FutureCom 10TEN values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom 10TEN values)
Frequency in MHz
Braided shield
Application
Halogen-free jacket, The cables for the FutureCom™ S10TEN System are designed
flame retardant for applications up to 1500 MHz (S/FTP 600 up to S/FTP 1500*).
Their transmission characteristics significantly exceed the
Twisted pair
requirements defined by today’s Category 7 specifications
Foil shielding (PiMF) (EN50288-4-1).
4 shielded pairs FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
PE foam-skin insulation
required for applications running 10 Gigabit Ethernet. The
Copper conductor possibility of using the cable up to the GHz area enables the
AWG 23 - AWG 22 highest possible transmission rates for multimedia applica-
tions, such as TV transmission, in future-proof networks.
* For S/FTP 600 and 900 cable please see pages 61-63. For
S/FTP 1500 and 1200 cable please see pages 18-20.
Features
Introduction
Fully compatible with all modular LANscape® systemes
Wide range of installation options
Few individual components
High-level component density
FutureCom F
Individual shielding
Halogen-free
Fire class UL94V-0
FutureCom 10TEN
Individual Components of the S10TEN Module
FutureCom E
FutureCom™ S10TEN Technology
FutureCom D
Optimized construction with printed circuit board for
bandwidths of more than 500 MHz
FutureCom UD FutureCom UE
More than 1500 connector cycles are possible
Proven IDC technology for wires with AWG 24 to AWG 22
Module reusable several times
Hardware
Disassembled S10TEN Module
Easy handling
Compatible with all FutureCom S/FTP cables
Special
Cable
TEN
Features
Ordering Information
Unit per
Order Number Description Delivery
CAXTSM-00112-C001 S10TEN Module, 1xRJ45, shielded, 1/1
10GBase-T, module aqua,
with transparent TIA/EIA 568 A/B
wire management, incl. copper
conducting tape for installation
in LANscape modular patch panels,
outlets and floor box solutions
Using the additional cable strain relief allows increased pulling forces on the module housings.
Unit per
Order Number Description Delivery
CAXCSN-00000-C001 Additional cable strain relief, 100/1
for fixing higher pulling forces
on shielded FutureCom modules
for solid wire, and for assembly of
flexible consolidation point cables
with FutureCom S10TEN fx, S250fx and
U250fx modules
TEN
Ordering Information
S10TEN Outlets
Introduction
Unit per
Order Number Description Delivery
FutureCom F
CAXTSD-S0201-C001 S10TEN Outlet, 2xRJ45, 1/1
shielded,10GBase-T,
inclined, incl. mounting frame
with grounding flaps,
FutureCom 10TEN
central plate 50x50 mm
with designation window, screw fixing,
copper conducting tape
(without faceplate),
FutureCom E
white, RAL 9010
FutureCom D
2xRJ45, shielded,10GBase-T,
inclined, incl. mounting frame with
grounding flaps, central plate 50x50 mm
with designation window, screw fixing,
FutureCom UD FutureCom UE
copper conducting tape
(without faceplate)
pearl white, RAL 1013
Hardware
S10TEN Patch Panel
Unit per
Description
Features
Ordering Information
CCATGB - G 002 - A - C0
1 2
Description
Introduction
The FutureCom™ 10TEN Consolidation Point Patch Cords are
factory terminated cable assemblies with one S10TEN fx
module and one RJ45 connector. FutureCom S/FTP flex/26
cable is specified up to 600 MHz and satisfies Category 7
FutureCom F
transmission characteristics. The CP Patch Cords are suitable
for connection from LANscape® Consolidation Point Hous-
ings to wall or desktop outlets.
FutureCom 10TEN
FutureCom E
Ordering Information
FutureCom D
FutureCom UD FutureCom UE
Order Number Description Length
S/FTP flex/26 Patch Cords, 4 pairs
application-neutral, FRNC sheath,
gray, pre-terminated with one RJ45
connector and one S10TEN fx module,
for 10GBase-T applications
CCATGB-F1062-A050-C0 CP Patch Cords S/FTP flex/26 - 5 5m
Hardware
CCATGB-F1062-A100-C0 CP Patch Cords S/FTP flex/26 - 10 10 m
CCATGB-F1062-A150-C0 CP Patch Cords S/FTP flex/26 - 15 15 m
CCATGB-F1062-A200-C0 CP Patch Cords S/FTP flex/26 - 20 20 m
Application
Ordering Information
Order Number Description Length
S10 Solution Package, with
TEN
Application
Introduction
The S10TEN Plug and Play™ Solution has been especially cre-
ated for use in data center applications. This special
assembly consists of six S/FTP 900/23 cables, with a com-
mon FRNC jacket. The cable is pre-terminated with six S10TEN
FutureCom F
modules at both ends. All modules are equipped with addi-
tional cable strain relief, to allow higher pulling force during
installation (the pulling force is restricted by the cable only).
FutureCom 10TEN
They enable rapid Plug and Play installation in data centers
and therefore significantly reduce installation time. 100%
factory testing reduces failures during installation.
FutureCom E
Ordering Information
FutureCom D
Order Number Description Length
FutureCom UD FutureCom UE
S10 Plug & Play Solution Package, with
TEN
Hardware
*Other lengths available upon request.
Installation Option
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Application
Ordering Information
Units per
Order Number Description Delivery
CCATGB-F10M0-A030-C0 Universal Test Cord for the acceptance tests 1/1
of the FutureCom 10 TEN
system in conjunction
with the universal test adapter from Fluke
or another test device manufacturers,
2xRJ45, 4 pairs, 3 m
4 FutureCom E
Introduction
4.1. System Descriptions & Data 56
4.2. Cable
FutureCom F
4.2.1. Cat. 7 S/FTP 900/23 and S/FTP 600/23 Cable 61
FutureCom 10TEN
4.2.3. Cat. 6 F/FTP 450/23 Cable 66
FutureCom E
4.3.2. Certificate for S250 Module 69
FutureCom D
4.3.4. S250fx Module 71
4.4. Hardware
FutureCom UD FutureCom UE
4.4.1. S250 Outlets and Patch Panel 72
Hardware
4.5.2. Consolidation Point Patch Cords 76
FutureCom E is Corning’s proven system solution for symmetrical cabling. It exceeds all requirements of the current ISO/IEC
11801 (2002) and EN 50173-1 (2003) standards, Class D and E links and Categories 5 and 6 for components. In addition, the
FutureCom E system also satisfies Category 5e according to TIA/EIA-568-A-5.
Face Plate
80x80 mm
“DELTAprofil”,
WAXWSE-00001-C001
and S250 outlet, S/FTP flex/26, blue,
2xRJ45, 2xRJ45 connectors,
Cat.6, inclined, 4 pairs,
CAXESD-S0201-C001 for 10/100/1000Base-T
CCAEGB-G2002-A020-C0
FutureCom
S/FTP 600/23
CCXEDB-F0047-C001-L7
19“ Patch Panel, for
S250 Module, max. 24 LANscape®
1 x RJ45,shielded, Cat. 6 modules,
CAXESM-00100-C001 with integrated cable
strain relief, 1 U,
front panel of
high-grade steel
S/FTP flex/26, blue, WAXWSV-02400-C001
2xRJ45- connectors,
4 pairs, for
10/100/1000 Base-T
CCAEGB-G2002-A020-C0
A very high level of system performance is achieved for the The system is suitable for all recognized standardized voice
link through the use of high-quality Category 6 connection and data transmission procedures. This applies to analog
technology, Category 6 and 7 cables and Category 6 patch voice transmission, ISDN,Token Ring, Ethernet (10/100Base-T),
cords. The resulting performance and the future security Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T)
guaranty maximum investment protection. and for future high bit-rate transmission procedures.
Fully configured with a RJ45 connector and RJ45 module, the The performance of the FutureCom E cabling system has
cabling can be used universally and is application-neutral. been certified by an independent testing body (see certifi-
cate). Of course, all standardized EMC threshold values in
Europe are observed.
Introduction
Max. attenuation in dB* 4.0 21.7 35.9
Attenuation in dB (typ. FutureCom™ E values) 2.1 5.5 8.0 12.5 16.5 20.0 24.0 27.0
– – – – –
FutureCom F
Min. ACR in dB* 61.0 18.2 – 2.8
ACR in dB (typ. FutureCom E values) 70.6 58.5 50.3 37.5 30.0 23.7 17.1 11.8
– – – – –
FutureCom 10TEN
ELFEXT in dB (typ. FutureCom E values) 73 65.0 60.0 48.0 46.0 38.8 35.0 33.3
– – – – –
FutureCom E
The system values cited only apply to the use of original FutureCom E products. Derived values, such as PSACR, PSNEXT,
PSELFEXT, are in observance of the standard values, but are not shown.
FutureCom D
Attenuation and
Near-end Crosstalk (NEXT)
FutureCom UD FutureCom UE
NEXT in dB
(typ. FutureCom E values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Hardware
Attenuation in dB
(typ. FutureCom E values)
Frequency in MHz
Industrial
Cable
Special
Cable
Information
Further
ELFEXT in dB
(typ. FutureCom™ E values)
Min. ELFEXT in dB
According to standard
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom E values)
Frequency in MHz
Test Setup
FutureCom E Test Cable, 2xRJ45, 3 m Nominal intrinsic impedance 100 V
S250 Module, 2xRJ45 Max. DC loop resistance (according to standard) 40 V
90 m FutureCom S/FTP900/23 DC loop resistance (typ. FutureCom E values) 18 V
S250 Patch Panel 19“ Max. delay (according to standard) 0.05 µs
FutureCom E Test Cable, 2 x RJ45, 3 m Max. delay (typ. FutureCom E values) , 0.02 µs
Introduction
FutureCom F
FutureCom 10TEN
FutureCom E
FutureCom D
Application
FutureCom UD FutureCom UE
Braided shield
The FutureCom™ S/FTP 900/23 and S/FTP 600/23 cables are
Halogen-free jacket,
designed for applications up to 1000/800 MHz and their
flame retardant
transmission characteristics exceed Category 7 specifica-
Twisted pair tions.
Foil shielding (PiMF) FutureCom cables are low-skew products. This is increas-
ingly required for applications above 1 Gigabit-Ethernet. The
Hardware
4 shielded pairs
suitability of the cable for utilization up to the GHz area
PE foam-skin insulation enables the highest possible transmission speeds in future-
proof networks. These cables have a streamlined construc-
Features
Introduction
Frequency in MHz 1 10 16 20 31.25 62.5 100 300 600 900 1000
Attenuation in dB/100m * 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.8 30.0 42.5 55.0 59.0
– –
FutureCom F
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100 m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 92.0 86.0 83.0
– –
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Typical values in dB at 100m
FutureCom 10TEN
98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0 90.0 84.0 81.0
– –
ELFEXT in dB at 100 m * 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
– –
PSELFEXT in dB at 100 m * 77.0 71.0 66.9 65.0 61.1 55.1 51.0 41.5 35.4
– –
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
FutureCom E
– –
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 31.0 24.0
– –
* Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
FutureCom D
Electrical Characteristics (at 20°C) for S/FTP 600/23
Frequency in MHz 1 10 16 20 31.25 62.5 100 300 600 800
FutureCom UD FutureCom UE
Attenuation in dB/100m * 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.8 30.7 44.0 53.0
–
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 95.0 91.0 87.0
–
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 98.0 97.0 93.0 89.0 85.0
–
ELFEXT in dB at 100 m * 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
–
Hardware
PSELFEXT in dB at 100 m * 77.0 71.0 66.9 65.0 61.1 55.1 51.0 41.5 35.4
–
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
–
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 82.1 64.3 47.0 34.0
–
Ordering Information
Max.
Fire Load Halogen- Tensile Outer [ Weight Length
Type designation Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
S/FTP 600/23 12P 7 12 1.89 Yes 462 7.7x25.0 195 500 CCXEDB-F0127-C001-L6
Further
* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.
Application
Braided shield
The FutureCom™ S/FTP 450/23 cables are designed for
Halogen-free jacket, applications of up to 600 MHz and their transmission
flame retardant
characteristics exceed Category 6 specifications.
Twisted pair
FutureCom cables are low-skew products, i.e. the skew
Foil shielding (PiMF)
between the individual pairs are very low. This is increas-
Introduction
Largest resistance margin 1%
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/– 20%
Impedance Zo at 1 - 100 MHz 100 V +/– 15%
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/– 18%
Surface transfer impedance <10 mV/m at 10 MHz / S/FTP
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
FutureCom 10TEN
Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz
Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz
Propagation velocity at > 10 MHz (NVP x c) 0.79 x c
Propagation delay >_ 10 MHz 4.2 ns/m
FutureCom E
Delay skew 4 ns/100 m
FutureCom D
Electrical Characteristics (at 20°C)
FutureCom UD FutureCom UE
Attenuation in dB/100m * 2.1 6.0 7.6 8.5 10.8 15.5 19.9 33.0
Typical values dB/100m 1.8 5.3 6.8 7.6 9.6 13.6 17.3 27.7 38.0 44.8
– –
NEXT in dB at 100 m * 66.0 59.3 56.2 54.8 51.9 47.4 44.3 38.3
Typical values in dB at 100 m >100.0 >100.0 >100.0 >100.0 >100.0 97.0 95.0 90.0 85.0 75.0
– –
PSNEXT in dB at 100 m * 64.0 57.3 54.2 52.8 49.9 45.4 42.3 36.3
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 95.0 93.0 88.0 83.0 73.0
– –
Hardware
– –
ACR in dB 98.2 94.7 93.2 92.4 90.4 83.4 77.7 62.3 47.0 30.2
ISDN Products
Telephone /
* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)
CableCable
Cord Cord
for Patch
Flex Wire
Ordering Information
for Patch
Flex Wire
Max.
Industrial
Type designation Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
Application
Foil shield (FTP) The FutureCom™ F/FTP 450/23 cables are designed for
Halogen-free jacket, applications of up to 450 MHz and their transmission
flame retardant characteristics exceed Category 6 specifications.
Twisted pair
FutureCom cables are low-skew products, i.e. the skew
Foil shielding (PiMF) between the individual pairs are very low. This is increas-
ingly required for Gigabit-Ethernet. These cables have a
4 shielded pairs
streamlined construction and low weight.
Additional wire
Each pair is individually shielded (PiMF). The stranded pairs
PE foam-skin insulation are additionally foil shielded (F/FTP), which guarantees out-
standing shielding characteristics. The cables satisfies Class
Copper conductor
B interference radiation standards (EN 55022), as well as im-
AWG 23
munity (EN 55024), which enables the realization of CE-com-
patible networks.
Introduction
Largest resistance margin 2%
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/– 20%
Impedance Zo at 1 - 100 MHz 100 V +/– 15%
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/– 18%
Surface transfer impedance 100 mV/m at 10 MHz
Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
FutureCom 10TEN
Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz
Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz
Propagation velocity at >10 MHz (NVP x c) 0.79 x c
Propagation delay >_ 10 MHz 4.3 ns/m
FutureCom E
Delay skew 4 ns/100 m
FutureCom D
Electrical Characteristics (at 20°C)
FutureCom UD FutureCom UE
Attenuation in dB/100m * 2.1 6.0 7.6 8.5 10.8 15.5 19.9 33.0
Typical values dB/100m 1.8 5.3 6.8 7.6 9.6 13.6 17.3 27.7 38.0
–
NEXT in dB at 100 m * 66.0 59.3 56.2 54.8 51.9 47.4 44.3 38.3
Typical values in dB at 100 m >100.0 >100.0 >100.0 >100.0 >100.0 97.0 95.0 90.0 85.0
–
PSNEXT in dB at 100 m * 64.0 57.3 54.2 52.8 49.9 45.4 42.3 36.3
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 95.0 93.0 88.0 83.0
–
Hardware
–
ACR in dB 98.2 94.7 93.2 92.4 90.4 83.4 77.7 62.3 47.0
Ordering Information
Max.
Industrial
Type designation Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
Features
Features
Wire Management
69
Further Special Industrial Flex Wire Cable Telephone /
Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction
Information Cable Cable for Patch Cord ISDN Products
FutureCom™ E
S250 Module
Features
Ordering Information
Unit per
Order Number Description Delivery
CAXESM-00100-C001 S250 Module, 1xRJ45, shielded, Cat.6, 1/1
incl. copper conducting tape for installation
in LANscape modular patch panels,
outlets and floor box solutions
Using the additional cable strain relief allows increased pulling force on the module housings.
Unit per
Order Number Description Delivery
CAXCSN-00000-C001 Additional cable strain relief, 100/1
for higher pulling force on shielded
FutureCom modules for solid wire,
and for assembly of flexible consolidation
point cables with FutureCom S10TEN fx,
S250fx or U250fx modules
Application
Introduction
S250fx Modules are used for the assembly of flexible cables
or consolidation point cables.
Features
FutureCom F
Fully compatible with all modular LANscape® connecting
hardware
FutureCom 10TEN
Wide range of installation options
Individual shielding
Proven IDC technology for AWG 24 and AWG 26 stranded
wires
FutureCom E
Module reusable several times
1500 connector cycles are possible Individual components of the S250fx Module
Wire management using A/B printing according to
FutureCom D
TIA/EIA 568
Installation in pairs (no untwisting of the pairs is
necessary)
Easy handling and very short assembly time
FutureCom UD FutureCom UE
Category 6, de-embedded
Hardware
according to TIA/EIA 568 B; when using other single-
ended pre-terminated connecting cables they should be
wired according to the RJ45 connector scheme
Ordering Information
Unit per
Order Number Description Delivery
Industrial
LANscape hardware
Information
Further
Ordering Information
S250 Outlets
Unit per
Order Number Description Delivery
S250 Outlet, 2xRJ45,
shielded, Cat. 6, inclined,
incl. mounting frame
with grounding flaps,
central plate 50x50 mm
with designation window,
screw-fixed, copper
conducting tape
(without face plate)
CAXESD-S0201-C001 white, RAL 9010 1/1
CAXESD-S0202-C001 pearl white, RAL 1013 1/1
Ordering Information
Introduction
Unit per
Order Number Description Delivery
CAXESD-S0200-C001 S250 Double Module Outlet, 1/1
FutureCom F
2xRJ45, Cat. 6, inclined,
incl. mounting frame with
grounding flaps and
copper conducting tape
FutureCom 10TEN
(suitable for Rutenbeck-
compatible central plates
or faceplates)
FutureCom E
FutureCom D
FutureCom UD FutureCom UE
Installation Option
Hardware
For example, mounted with a high grade steel face plate
from Jung
Description
Introduction
The FutureCom E System patch cords consist of Category 6
flex cable with shielded RJ45 connectors at both ends. The
flex cables have four individual foil-shielded pairs and full
braid copper shielding. The zero halogen patch cords (LSZH)
FutureCom F
are non-corrosive (according to IEC 60754-2), low smoke
(according to IEC 61034) and flame retardant (according to
IEC 60332-1, Category B). They are available in various
FutureCom 10TEN
lengths and colors.
Features
FutureCom E
S/FTP flex cable, specified up to 600 MHz
FutureCom D
Application-neutral due to using all four pairs
Minimum surface transfer impedance
(<10 mV/m at 10 MHz)
Outstanding transmission characteristics according to
FutureCom UD FutureCom UE
Channel E (2002)
Cat. 6
Ordering Information
Hardware
CCAEGB - G 002 - A - C0
1 2
Description
Ordering Information
Application
Introduction
The S250 Solution Packages are pre-terminated cables with
S250 modules at both ends. They are generally offered with
FutureCom™ S/FTP 900/23 cables. Both modules are
FutureCom F
equipped with additional cable strain relief, to allow higher
pulling forces during insertion (the pulling force is restricted
by the cable only). They enable Plug and Play™ installation
FutureCom 10TEN
and therefore significantly reduce installation time.
FutureCom E
FutureCom D
Ordering Information
FutureCom UD FutureCom UE
Order Number Description Length
Solution Package, S/FTP900/23 cable,
4 pairs, FRNC jacket pre-terminated
with 2 S250 modules
and additional cable strain relief
CCAEDB-D2050-A100-C0 S250 Solution Package S/FTP 900/23 - 10 10 m
Hardware
CCAEDB-D2050-A150-C0 S250 Solution Package S/FTP 900/23 - 15 15 m
CCAEDB-D2050-A200-C0 S250 Solution Package S/FTP 900/23 - 20 20 m
CCAEDB-D2050-A250-C0 S250 Solution Package S/FTP 900/23 - 25 25 m
CCAEDB-D2050-A300-C0 S250 Solution Package S/FTP 900/23 - 30 30 m
Application
The S250 Plug and Play™ Solution has been especially cre-
ated for use in data center applications. This special
assembly consists of six S/FTP 900/23 cables, with a com-
mon FRNC jacket. The cable is pre-terminated with six S250
modules at both ends. All modules are equipped with addi-
tional cable strain relief, to allow higher pulling force during
installation (the pulling force is restricted by the cable only).
They enable rapid Plug and Play installation in data centers
and therefore significantly reduce installation time. 100%
factory testing reduces failures during installation.
Ordering Information
Order Number Description Length
S250 Plug & Play Solution Package, with
6x S/FTP 900/23 cables with common
FRNC jacket, both ends terminated
with 6 S250 modules,
and additional cable strain relief
CCAEDB-D2650-A200-C0 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 20 20 m
CCAEDB-D2650-A300-C0 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 30 30 m
CCAEDB-D2650-A400-C0 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 40 40 m
Installation Option
Application
Introduction
The universal channel test cord can be used for acceptance
tests of shielded FutureCom™ E Systems in conjunction with
the universal test adapter from Fluke or other test device
manufactureres.
FutureCom F
One pair of these test cords is required for acceptance tests.
FutureCom 10TEN
Ordering Information
Units per
FutureCom E
Order Number Description Delivery
CCAEGB-D10M0-A030-C0 Universal Test Cord, for the acceptance test 1/1
of the FutureCom E System in conjunction
with the universal test adapter from Fluke
FutureCom D
or other test device manufacturers,
2xRJ45, 4 pairs, 3 m
FutureCom UD FutureCom UE
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
5 FutureCom D
Introduction
5.1. System Descriptions & Data 82
5.2. Certificates 85
FutureCom F
5.3. Cable
FutureCom 10TEN
5.3.2. Cat. 5 SF/UTP 300/24 FRNC, 16P Cable 88
FutureCom E
5.4.1. S100e Module Overview 92
FutureCom D
5.5. Hardware
FutureCom UD FutureCom UE
5.5.2. S100e Double Module Outlet 95
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
FutureCom D (2002) is Corning’s Class D system solution for symmetrical cabling. It fulfils all requirements of the current
ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards, Class D for links and Category 5 for the components. In addition,
the FutureCom D system also satisfies Category 5e according to TIA/EIA-568-A-5.
Face Plate
80x80 mm
“DELTAprofil”,
WAXWSE-00001-C001
and SF/UTP flex/26, green,
S100e outlet, 2xRJ45, 2xRJ45 connectors,
Cat.5, inclined, 4 pairs,
CAXDSD-S0201-C001 for 10/100/1000Base-T
CCADGF-D4002-A030-C0
FutureCom
SF/UTP 300/24 Cable
CCXDEF-I0047-C001-L7
19“ Patch Panel, for
S100e Module, max. 24 LANscape®
1xRJ45, shielded, modules,
Cat. 5 with integrated cable
CAXDSM-00100-C001 strain relief, 1 U,
front panel of
high-grade steel
SF/UTP flex/26, green, WAXWSV-02400-C001
2xRJ45- connectors,
4 pairs, for
10/100/1000 Base-T
CCADGF-D4002-A020-C0
A high level of system performace is achieved for the entire FutureCom D cabling that conforms to the standards is
link through the use of high-quality Category 5 connection suitable for all recognized standardized voice and data
technology, cables and patch cords. The resulting perfor- transmission procedures. This applies to analog voice trans-
mace, and future security, guarantees a high degree of mission, ISDN, Token Ring, Ethernet (10-Base-T), Ethernet
investment protection for the cabling. (100Base-TX) and Gigabit Ethernet (1000Base-T).
Fully configured with RJ45 connectors and RJ45 modules, the The performance of the FutureCom D cabling system has
cabling is application-neutral and can be used universally. been certified by an independent test body (see certificate).
Of course, all standardized EMC threshold values in Europe
are observed.
Introduction
Max. attenuation in dB* 4.0 9.1 24.0
Attenuation in dB (typ. FutureCom™ D values) 2.3 3.5 5.8 7.0 8.5 10.0 16.0 19.0
– – – – –
FutureCom F
Min. ACR in dB* 56.0 34.5 6.1
ACR in dB (typ. FutureCom D values) 67.7 56.5 49.2 44.0 39.2 34.0 22.0 17.0
– – – – –
FutureCom 10TEN
ELFEXT in dB (typ. FutureCom D values) 70.0 60.0 52.0 48.0 46.0 43.0 38.0 34.0
– – – – –
FutureCom E
The system values cited are only valid with regard to the use of original FutureCom D products. Derived values,
such as PSACR, PSNEXT and PSELFEXT, maintain the required standard values but are not shown for clarity of presentation.
FutureCom D
Attenuation and
Near-end Crosstalk (NEXT)
FutureCom UD FutureCom UE
NEXT in dB
(typ. FutureCom D values)
min. NEXT in dB
According to standard
max. Attenuation in dB
According to standard
Hardware
Attenuation in dB
(typ. FutureCom D values)
Frequency in MHz
Industrial
Cable
Special
Cable
Information
Further
ELFEXT in dB
(typ. FutureCom™ D values)
Min. ELFEXT in dB
According to Norm
Frequency in MHz
Return Loss
Return loss in dB
(typ. FutureCom D values)
Frequency in MHz
Application
Braided shield
The FutureCom SF/UTP 300/24 cable is designed for applica-
Halogen-free jacket,
flame retardant or PVC tions of up to 300 MHz and its transmission characteristics
exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5)
Twisted pair specifications.
Foil shielding
FutureCom cables are low-skew products, i.e. the skew
4 shielded pairs between the individual pairs is very low. This is increasingly
required for Gigabit-Ethernet. The cable has a streamlined
PE foam-skin insulation
construction and low weight.
Copper conductor
AWG 24 The four stranded pairs are sheathed with a foil shield
(F/UTP) and, additionally, with a braided shield (SF/UTP),
which guarantee outstanding shielding characteristics. The
cable satisfies the standard for Class B interference radiation
(EN 55022), as well as immunity (EN 55024), which enables
the realization of CE-compatible networks.
Color Coding
Pair 1 white with blue rings/blue
Features
Pair 2 white with orange rings/orange
SF/UTP 300/24 cable, specified up to 300 MHz
Pair 3 white with green rings/green
Pair 4 white with brown rings/brown Outstanding electrical characteristics
Full braid copper shield
Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH) jacket
Flame retardant according to IEC 60332-3, Category C
PVC jacket, flame retardant, according to IEC 60332-1,
Category B
FRNC is non-corrosive according to IEC 60754-2
Introduction
Conductor insulation PVC: PE Foam skin Largest resistance margin 1%
FRNC: Halogen-free Insulation resistance >5000 MV x km
Foam-skin Impedance Zo at 0.064 MHz 125 V +/– 20%
Sheath material Halogen-free, Impedance Zo at 1 - 100 MHz 100 V +/– 15%
FutureCom F
flame retardant Surface transfer impedance <10 m V/m
Area/range of application Dry and at 10 MHz
damp rooms Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
FutureCom 10TEN
Temperature range (installation) 0 to +50°C Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz
Operating temperature -20 to +60°C Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz
Min. bending radius >_ 35 mm (for 2 x Propagation velocity
for one-time bending (4x2...) over flat side) at >10 MHz (NVP x c) 0.74 x c
FutureCom E
Min. bending radius during >_ 50 mm (for 2 x Propagation delay >_ 10 MHz 4.5 ns/m
installation (4x2...) over flat side) Delay skew 7 ns/100 m
Copper conductor AWG 24
FutureCom D
Electrical Characteristics (at 20°C)
Frequency in MHz 1 10 16 20 31.25 62.5 100 250 300
FutureCom UD FutureCom UE
Attenuation in dB/100m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 2.0 5.6 7.2 8.0 10.1 14.4 18.2 29.5 32.2
– –
Hardware
Typical values in dB at 100m 72.0 60.0 54.0 52.0 48.0 40.0 34.0 22.1 17.0
– –
ACR in dB 75.0 56.4 51.8 49.0 43.9 35.6 27.8 9.0 2.8
Ordering Information
Max.
No. of Fire Load Halogen- Tensile Outer [ Weight Length
Type designation Category Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
Industrial
Cable
* X1 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.
Halogen-free
external jacket, Application
flame retardant
Foil shielding
Metal-free FutureCom cables are low-skew products, i.e. the skew
central element between the individual pairs is very low. This is increasingly
Twisted pair required for Gigabit-Ethernet.
4 shielded pairs The four stranded pairs are foil shielded (F/UTP) additionally
with a braided shield (SF/UTP), which guarantees outstand-
Foam-skin PE
insulation ing shielding characteristics. The cable satisfies the standard
for Class B interference radiation (EN 55022), as well as im-
Copper conductor
AWG 24 munity (EN 55024), which enables the realization of CE-
compatible networks. The Quattro configuration with a
shared external sheath for the FutureCom SF/UTP 300/24
16P cable, allows increased mechanical load and enables
cost-optimized installation.
Introduction
Conductor insulation Halogen-free Largest resistance margin 1%
Foam-skin material Insulation resistance >5000 MV x km
Outer jacket Halogen-free, Impedance Zo at 0.064 MHz 125 V +/– 20%
flame retardant Impedance Zo at 1 - 100 MHz 100 V +/– 15%
FutureCom F
Area/range of application Dry and Surface transfer impedance <10 m V/m
damp rooms at 10 MHz
Temperature range (installation) 0 to +50°C Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
FutureCom 10TEN
Operating temperature -20 to +60°C Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz
Min. bending radius >_ 85 mm Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz
for one-time bending Propagation velocity
Min. bending radius during >_ 120 mm at >10 MHz (NVP x c) 0.74 x c
FutureCom E
installation Propagation delay >_ 10 MHz 4.5 ns/m
Copper conductor AWG 24 Delay skew 7 ns/100 m
FutureCom D
Electrical Characteristics (at 20°C)
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 250 300
Attenuation in dB/100m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 2.0 5.6 7.2 8.0 10.1 14.4 18.2 29.5 32.2
– –
Hardware
– –
ACR in dB 75.0 56.4 51.8 49.0 43.9 35.6 27.8 9.0 2.8
* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)
Ordering Information
Industrial
Cable
Max.
Fire Load Halogen- Tensile Outer [ Weight Length
Type designation Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
Special
Cable
SF/UTP 300/24 16P 5e 16 4.04 Yes 328 16.5 280 1000 CCXDEF-C0167-C001-L7
Information
Further
Additional wire FutureCom cables are low-skew products, i.e. the skew be-
tween the individual pairs are very low. This is increasingly
PE foam-skin insulation
required for Gigabit-Ethernet. The cable has a streamlined
Copper conductor construction and low weight.
AWG 24
4 shielded pairs The four stranded pairs are foil shielded (F/UTP). The cable
satisfies the standards for Class B interference radiation
(EN 55022), as well as immunitiy (EN 55024), which enables
the realization of CE-compatible networks.
Pair 1 white with blue rings/blue F/UTP 300/24 cable, specified up to 300 MHz
Pair 2 white with orange rings/orange Outstanding electrical characteristics
Pair 3 white with orange rings/orange Full shielding with 2 foils and additional copper wire
Pair 4 white with orange rings/orange Streamlined design
Lightweight
Low skew between the pairs
Halogen-free (LSZH) jacket
Flame retardant according to IEC 60332-3, Category C
PVC jacket, flame retardant according to IEC 60332-1,
Category B
Non-corrosive according to IEC 60754-2 (FRNC)
Introduction
Conductor insulation PVC: PE foam skin Largest resistance margin 1%
FRNC: Halogen-free Insulation resistance >5000 MV x km
Foam-skin Impedance Zo at 0.064 MHz 125 V +/– 20%
Impedance Zo at 1 - 100 MHz 100 V +/– 15%
FutureCom F
Outer jacket Halogen-free,
flame retardant Surface transfer impedance <10 m V/m
Area/range of application Dry and at 10 MHz
damp rooms Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz
FutureCom 10TEN
Temperature range (in motion) 0 to +50°C Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz
Operating temperature -20 to +60°C Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz
Min. bending radius >_ 35 mm (for 2x Propagation velocity
for one-time bending (4x2...) over flat side) at >10 MHz (NVP x c) 0.74 x c
FutureCom E
Min. bending radius during >_ 50 mm (for 2x Propagation delay >_ 10 MHz 4.5 ns/m
installation (4x2...) over flat side) Delay skew 7 ns/100 m
Copper conductor AWG 24
FutureCom D
Electrical Characteristics (at 20°C)
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 250 300
Attenuation in dB/100m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 2.0 5.6 7.2 8.0 10.1 14.4 18.2 29.5 32.2
– –
Hardware
Typical values in dB at 100m 72.0 60.0 54.0 52.0 48.0 40.0 34.0 22.1 17.0
– –
Ordering Information
Max.
Fire Load Halogen- Tensile Outer [ Weight Length
Type designation Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number
Industrial
Cable
*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.
Features
Features
Wire Management
Features
Introduction
Easy and quick to install, no special tools required
IDC connection (IDC = Insulation Displacement Contacts)
High-level component density
Universal application in all modular LANscape® and
FutureCom F
FutureCom™ components
Negligible disturbance effect from interference by means
of the individual shielding of the modules
FutureCom 10TEN
Utilization of additional cable strain relief
CAXCSN-00000-C001 is possible for increased pulling
forces
FutureCom E
Ordering Information
FutureCom D
Unit per
Order Number Description Delivery
CAXDSM-00100-C001 S100e Module, 1xRJ45, shielded, Cat.5 (2002), 1/1
for wire diameter AWG 24 to AWG 23
FutureCom UD FutureCom UE
(F/UTP and SF/UTP cables), incl. copper
conducting tape for installation in
LANscape patch panels,
outlets and floor box solutions
Hardware
CAXDSM-00200-C001 S100e Double Module, 2xRJ45, shielded, 1/1
Cat.5 (2002), for wire diameter AWG 24
to AWG 23 (F/UTP and SF/UTP cable),
patch cords.
Ordering Information
S100e Outlets
Unit per
Order Number Description Delivery
S100e Outlet, 2xRJ45,
Cat. 5/Cat. 5e, shielded,
inclined, incl. mounting
frame with grounding
flaps, 50x50 mm central
plate with designation
window, screw fixings,
copper conducting tape
(without face plate)
CAXDSD-S0201-C001 white, RAL 9010 1/1
CAXDSD-S0202-C001 pearl white, RAL 1013 1/1
Ordering Information
Introduction
Unit per
Order Number Description Delivery
CAXDSD-S0200-C001 S100e Double Module Outlet, 1/1
2x RJ45, Cat. 5, inclined,
FutureCom F
incl. mounting frame with
grounding flaps and
copper conducting tape
(suitable for Rutenbeck-
FutureCom 10TEN
compatible central plates
or face plates)
FutureCom E
FutureCom D
Installation Option
FutureCom UD FutureCom UE
S100e Double Module Outlet, 2x RJ45, Cat.5, inclined,
incl. mounting frame and copper conducting tape.
CAXDSD-S0200-C001
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Ordering Information
S100eL Outlets
Unit per
Order Number Description Delivery
S100eL Outlet,
2xRJ45, Cat. 5/Cat. 5e,
inclined, incl. mounting
frame with grounding
flaps, 50x50 mm central
plate with designation
window, screw fixings,
copper conducting tape
(without face plate)
CAXGSD-S0201-C001 white, RAL 9010 1/1
CAXGSD-S0202-C001 pearl white, RAL 1013 1/1
A Class E link can be constructed using S100eL patch panels and outlets, in conjunction
Introduction
WAXWSE-S0301-C001
FutureCom F
with one MT-RJ module adapter frame
LAXLSN-00101-C001
with one MT-RJ adapter for multimode connector
FutureCom 10TEN
ADP-MTRJ-CNKFL-CLS
and two blue SF/UTP flex/26 patch cords
CCADNF-D2002-A030-C0
FutureCom E
Combi-Frame “DELTAprofil”
FutureCom D
mounting frame and central plate 50x 50 mm with
designation window, screw fixed, white, RAL 9010:
CAXDSD-S0201-C001
FutureCom UD FutureCom UE
equipped with one red labeling icon
WAXWSE-00007-C001
one gray labeling icon
WAXWSE-00003-C001
and one red SF/UTP flex/26 patch cord
CCADNF-D5002-A020-C0
combined with surface mount housing
WAXWSE-00001-C003
Hardware
and one “DELTAfläche” face plate
Double Surface Mount Outlet
WAXWSE-00001-C002
Description
Features
Ordering Information
CCAD F -D 002 - A - C0
1 2 3
Application
Introduction
The S100e Solution Packages are pre-terminated cable
sections with S100e modules at both ends. They are gener-
ally offered with FutureCom™ F/UTP 300/24 cables. Both
modules are equipped with additional cable strain relief to
FutureCom F
allow higher pulling force during installation (the pulling
force is restricted by the cable). They enable Plug and Play™
installation and therefore significantly reduce installation
FutureCom 10TEN
time. 100% factory testing reduces failures during installa-
tion.
FutureCom E
FutureCom D
Ordering Information
FutureCom UD FutureCom UE
Order Number Description Length
S100e Solution Package with F/UTP 300/24
data cable, 4 pairs, FRNC jacket pre-terminated
with two S100e modules
and additional cable strain relief
CCADEE-B2044-A100-C0 S100e Solution Package F/UTP 300/24 - 10 10 m
CCADEE-B2044-A150-C0 S100e Solution Package F/UTP 300/24 - 15 15 m
Hardware
CCADEE-B2044-A200-C0 S100e Solution Package F/UTP 300/24 - 20 20 m
CCADEE-B2044-A250-C0 S100 Solution Package F/UTP 300/24 - 25
e
25 m
CCADEE-B2044-A300-C0 S100e Solution Package F/UTP 300/24 - 30 30 m
CCADEE-B2044-A350-C0 S100e Solution Package F/UTP 300/24 - 35 35 m
8 Hardware
Introduction
8.1. Outlets and Outlet Accessories
FutureCom F
8.1.2. Metal Outlets 138
FutureCom 10TEN
8.3. Patch Panel and Patch Panel Accessories 152
FutureCom E
8.6. 1000 RT 162
FutureCom D
FutureCom UD FutureCom UE
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
Application
Ordering Information
Units per
Order Number Description Delivery
Blank Cover, 1 position
for installation in modular
LANscape patch panels,
outlets and floor box solutions
WAXWSM-00101-C001 white, RAL 9010 6/1
WAXWSM-00108-C001 black, RAL 9005 6/1
Ordering Information
Introduction
Frame Sets for the Individual Configuration of Outlets
Units per
Order Number Description Delivery
FutureCom F
Frame Set, inclined, with grounding
flap, for 2 LANscape® modules,
including mounting frame and
FutureCom 10TEN
50x50 mm central plate with designation
window, screw fixing
WAXWSE-S0201-C001 white, RAL 9010 1/1
WAXWSE-S0202-C001 pearl white, RAL 1013 1/1
FutureCom E
Design Line - Special Color Options
FutureCom D
Frame Set, inclined, with grounding
flap, for 2 LANscape® modules,
including mounting frame and
50x50 mm central plate with designation
FutureCom UD FutureCom UE
window, screw fixing
WAXWSE-S0203-C001 gray, RAL 7035 1/1
Hardware
including mounting frame and
50x50 mm central plate with designation
window, screw fixing
Ordering Information
Frame Set, inclined, projecting, 3- or 6-Port Outlet
Units per
Order Number Description Delivery
Frame Set, inclined, projecting,
for 3 LANscape® modules,
including mounting frame
and triple housing
with designation window,
dust protection flaps
and face plate 80x80 mm
WAXWSE-V0301-C001 white, RAL 9010 1/1
WAXWSE-V0302-C001 pearl white, RAL 1013 1/1
Introduction
All frame sets with a 50x50 mm central plate as well as the
3- and 6-port frame sets offer the opportunity to code each
port with labeling icons. The icons indicate port applications
and show a telephone or a computer (LAN operation). They
FutureCom F
are available in six different colors. Furthermore, these
frame sets have a designation window with a clear cover, for
inserting a designation label.
FutureCom 10TEN
Ordering Information
FutureCom E
Units per
Order Number Description Delivery
WAXWSE-00003-C001 Labeling Icon, computer/telephone, 120/1
FutureCom D
gray, RAL 7042
WAXWSE-00004-C001 Labeling Icon, computer/telephone, 120/1
blue, RAL 5015
WAXWSE-00005-C001 Labeling Icon, computer/telephone, 120/1
FutureCom UD FutureCom UE
yellow, RAL 1021
WAXWSE-00006-C001 Labeling Icon, computer/telephone, 120/1
green, RAL 6029
WAXWSE-00007-C001 Labeling Icon, computer/telephone, 120/1
red, RAL 3000
WAXWSE-00008-C001 Labeling Icon, computer/telephone, 120/1
black, RAL 9005
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
WAXWSE-00001-C009 DIN A4 Title Strip Sheet, 10/1
with 150 designation labels
for LANscape® outlets, white,
e.g. for labeling using a PC-printer
Industrial
Cable
Special
Cable
Information
Further
Ordering Information
Ordering Information
Introduction
Combi-Frames
Units per
FutureCom F
Order Number Description Delivery
“DELTAprofil” Combi-Frame, 80x80 mm,
inclined, for 3 LANscape® modules
WAXWSE-S0301-C001 white, RAL 9010 1/1
FutureCom 10TEN
WAXWSE-S0302-C001 pearl white, RAL 1013 1/1
FutureCom E
“DELTAfläche” Combi-Frame, 75x75 mm,
FutureCom D
inclined, for 3 LANscape modules
WAXWSE-S0301-C002 white, RAL 9010 1/1
WAXWSE-S0302-C002 pearl white, RAL 1013 1/1
FutureCom UD FutureCom UE
Installation Options
Hardware
inclined , white, RAL 9010;
WAXWSE-S0301-C001
“DELTAprofil”Combi-Frame
WAXWSE-S0301-C002
CAXDSM-00100-C001
and one single MT-RJ Module for single-mode/multimode
connectors
Information
Further
LAXLSM-00101-C004
“DELTAprofil” Combi-Frame
The following brackets can be used for the quick and simple
installation of outlets and frame sets in raceways.
Ordering Information
Units per
Order Number Description Delivery
WAXWSE-00001-C010 Brackets for Raceway Mounting of outlets 1/1
and frame sets, T-groove mounting,
height 50 mm, with half-shell partition,
white, RAL 9010
Ordering Information
Introduction
Units per
Order Number Description Delivery
WAXWSE-00001-C008 Surface Mount Housing, 67x110 mm, 1/1
FutureCom F
for combi-frame (67x110 mm),
white, RAL 9010
FutureCom 10TEN
FutureCom E
WAXWSE-V0201-C004 Combi-Frame, 67x110 mm, 1/1
for installation of two
FutureCom D
single LANscape® modules,
inclined,
white, RAL 9010
FutureCom UD FutureCom UE
CAXCSE-G0201-C001 Combi-Frame, 45x45 mm, 1/1
with self-closing shutters for
the installation of 2 FutureCom™
modules, straight,
Hardware
white, RAL 9010
Ordering Information
Units per
Order Number Description Delivery
WAXWSE-00001-C004 Surface Mount Housing, 87x87 mm, 1/1
including two screws for face plate
(87x87 mm),
white, RAL 9010
Ordering Information
Introduction
Units per
Order Number Description Delivery
CAXCSE-V0201-C001 Module Housings with 1/1
FutureCom F
self-closing shutters, projecting,
inclined, for face plates
(147x87 mm and 87x87 mm)
for the installation of 2 FutureCom™
FutureCom 10TEN
modules, white, RAL 9010
FutureCom E
WAXWSE-V0201-C002 Universal Module Housing, 1/1
projecting, inclined,
FutureCom D
for face plates (147x87 mm and
87x87 mm) for the installation of
2 FutureCom™ modules,
central partition provided,
FutureCom UD FutureCom UE
white, RAL 9010
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
Application
Features
Ordering Information
Unit per
Order Number Description Delivery
WAXWSD-V0208-C001 2-Port Metal Outlet 1/1
for Industrial Applications,
60x65x121 mm (HxWxD),
for the installation
of 2 LANscape modules,
inclined, projecting,
with designation window,
metal construction with
integrated cable strain relief,
anthracite, RAL 7016 *
Introduction
FutureCom F
FutureCom 10TEN
FutureCom E
Horizontal top hat rail: Horizontal top hat rail: Horizontal top hat rail: Vertical top hat rail:
Upper top hat rail clip Middle top hat rail clip Lower top hat rail clip Middle top hat rail clip,
rotated 90°
FutureCom D
The top hat rail clips can be assembled in four different positions, since distributor cabinets (e.g. robot or machine controls)
often have different distances between the top hat rails and the cabling conduits. In addition, there are two diagonally posi-
tioned drilled holes in the back of the outlet housing, so that the metal outlet can be mounted directly on the surface by re-
moving the top hat rail clip.
FutureCom UD FutureCom UE
Installation Option
2-port Metal Outlets for Industrial Applications, 60 x 65 x 121 mm (HxWxD), for the installation of two LANscape® modules,
inclined, with designation window, metal construction with integrated cable strain relief, anthracite, RAL 7016;
WAXWSD-V0208-C001
equipped with one S1200 Module,
Cat. 7
Hardware
CAXFSM-00100-C001
in one S1200 Module Adapter
CAXFSN-00110-C001
(Right side) Basic housing with mounted copper and fiber optic cables
Application
Features
Ordering Information
Unit per
Order Number Description Delivery
WAXWSD-V0408-C001 4-Port Metal Outlet 1/1
for Industrial Applications,
79x101x121 mm (HxWxD),
for the installation of
max. 4 LANscape modules,
inclined, with designation
window, metal construction
with integrated cable strain
relief, integrated grounding
pin, easy retrofitting of the
optional splice tray,
WAXLSD-0000-C001,
anthracite, RAL 7016 *
* other colors upon request
Installation Option
Introduction
4-port Metal Outlet for Industrial Applica-
tions, 79 x 101 x 121 mm (HxWxD), for the
installation of max. 4 LANscape® mo-
FutureCom F
dules, inclined, with designation window,
metal construction with integrated cable
strain relief, integrated grounding pin,
FutureCom 10TEN
anthracite, RAL 7016;
WAXWSD-V0408-C001
FutureCom E
Cat.7
CAXFSM-00100-C001
Closed metal outlet Basic housing
one a S1200 module with mounted copper cables
FutureCom D
CAXFSN-00110-C001
one S250 module, Cat. 6
CAXESM-00100-C001
and with one SC duplex module
FutureCom UD FutureCom UE
LAXLSM-00201-C001
with dust protection flap for SC duplex
multimode connector, beige
LAXLOK-00013-C001
equipped with splice tray
WAXLSD-00000-C001
incl. two stored crimp-splice
connections of two SC pigtails
Hardware
.... mounted on a top hat rail Basic housing with mounted copper and Splice tray (rear side) with
FO cables incl. splice tray mounted splice connections
Ordering Information
Units per
Order Number Description Delivery
WAXLSD-00000-C001 Splice Tray for 4-Port Metal Outlets, 1/1
15x96x92 mm (HxWxD),
Industrial
Cable
Description Features
The LANscape® metal outlet is constructed entirely from Metal construction suitable for harsh environmental
metal and is intended for wall surface mounting or conditions
mounting in false floors. It offers space for four LANscape® Cable strain relief for individual cables at cable entry in
fiber optic or copper modules. The outlet is especially the basic housing using cable ties
designed for security applications. Connection protection and security against accidental or
unauthorized access
Fastening of the housing cover using a central screw,
which can be protected, e.g. using a security label
Excess length storage for fiber optic cable, maintaining
the minimum bending radius
Basic housing designed to be conductive
(important when using FutureCom™ copper modules)
Standard fastening shape (60 mm hole spacing)
Horizontal and vertical top hat rail mounting
Ordering Information
Unit per
Order Number Description Delivery
WAXWSD-U0407-C001 Metal Outlet, 4-Port 1/1
45x93x143.5 mm (HxWxD),
for the installation of 4
LANscape individual
modules, straight, metal
construction with
integrated strain relief,
patchcord protection
and excess length storage
for FO cables,
red, RAL 3000 *
Description Features
Introduction
The LANscape® metal outlet is constructed entirely from Metal construction, suitable for harsh environmental
metal and is intended for wall surface mounting, raceway conditions
mounting or mounting in false floors. It offers space for Cable strain relief for individual cables in the basic
four four LANscape fiber optic or copper modules. housing using cable ties
FutureCom F
Fastening of the housing cover using a central screw
Excess length storage for FO cables of max. length
0.6-1.0 m, for maintaining the minimum bending radius
FutureCom 10TEN
Basic housing designed to be conductive
(important when using copper modules)
Standard fastening shape (60 mm hole spacing)
Horizontal and vertical top hat rail mounting
FutureCom E
FutureCom D
Closed metal outlets
with mounted
copper cables
FutureCom UD FutureCom UE
Ordering Information
Unit per
Order Number Description Delivery
WAXWSD-U0407-C002 Metal Outlet, 4-Port 1/1
45x93x87 mm (HxWxD),
for the installation of 4
Hardware
LANscape individual
modules, straight,
metal construction with
Applications
Description
Splicing of pigtails is possible in the floor box in combina- Mounting in the Ackermann GES4 Floor Box
tion with the protection box and a special splice tray.
Ordering Information
Mounting Panels for Ackermann Floor Boxes
Introduction
Units per
Order Number Description Delivery
WAXWSU-00600-C003 Mounting Panel for Ackermann 1/1
FutureCom F
Floor Boxes GES 2, GES 4, GES 4/10,
GESR 4, GES 6, GES 6/10, GESR 7/10
(outer mounting position only)
FutureCom 10TEN
or GES 8/10, for the installation of
6 LANscape modules, with integrated
strain relief and six cable ties,
designation window, metal, black
FutureCom E
WAXWSU-00900-C003 Mounting Panel for Ackerman 1/1
FutureCom D
Floor Boxes GESR 7/10 (middle
mounting position only), GES 9
or GESR 9, for the installation of
9 LANscape modules, with integrated
FutureCom UD FutureCom UE
strain relief and nine cable ties,
designation window, metal, black
Hardware
Units per
Order Number Description Delivery
WAXWSU-00900-C005 Mounting Panel for VanGeel Floor Box 1/1
Ordering Information
Mounting Panels for Kleinhuis Floor Boxes
Units per
Order Number Description Delivery
WAXWSU-00900-C002 Mounting Panel for Kleinhuis 1/1
Floor Box GR. II or GR. III
(outer mounting position
only in the round box),
for the installation of 9 LANscape®
modules, with integrated cable
strain relief and nine cable ties,
designation window, metal, black
Ordering Information
Mounting Panels for OBO Bettermann Floor Boxes
Introduction
Units per
Order Number Description Delivery
WAXWSU-00900-C007 Mounting Panel for OBO Bettermann 1/1
FutureCom F
Floor Boxes GE 12 R/5,GE 12R/10,
GE 12 RK/5,GE 12RK/10, (left, center,
right), for the installation of
FutureCom 10TEN
9 LANscape® modules, with
integrated cable strain relief
and nine cable ties,
designation window, metal, black
FutureCom E
FutureCom D
Protection Boxes for Mounting Panels
Units per
Order Number Description Delivery
FutureCom UD FutureCom UE
WAXWSU-00000-C003 Protection Box for Ackermann 1/1
Floor Boxes (GES 2, GES 4,
GES 4/10, GESR4, GES 6, GES 6/10,
GESR 7/10 (only outer mounting
position) or GES 8/10, with integrated
cable management, metal, black
Hardware
WAXWSU-00000-C004 Protection Box for Ackermann 1/1
Ordering Information
Protection Boxes for Mounting Panels
Units per
Order Number Description Delivery
WAXLSU-00000-C005 Splice Tray for Protection Box 1/1
WAXWSU-00000-C003
(Ackermann GES 2, GES 4, GES 4/10,
GESR 4, GES 6, GES 6/10, GESR 7/10,
outer mounting position only, or
GES 8/10), with splice organizer for
the storage of 12 crimp-splice
protectors, metal, black
Features
Units per
Order Number Description Delivery
WAXWSU-00100-C001 Mounting Panel for Ackermann 1/1
Floor Boxes GESR 2, for the
installation of one LANscape
module, with grounding flap,
metal, high-grade steel
Ordering Information
Introduction
Mounting Panels for Ackermann Floor Boxes
Units per
Order Number Description Delivery
FutureCom F
WAXWSU-00600-C004 Mounting Panel for Ackermann 1/1
Floor BoxGES 2,GES 4, GES 4/10,
GESR 4, GES 6, Ges6/10, GES7/10
FutureCom 10TEN
(outside) or GES 8/10 for the
installation of 6 LANscape® modules,
high-grade steel
FutureCom E
WAXWSU-00900-C001 Mounting Panel for Ackermann 1/1
FutureCom D
Floor Box GESR 7/10 (center), GES 9,
or GESR 9, for the installation of
9 LANscape modules,
high-grade steel
FutureCom UD FutureCom UE
Installation Option
Hardware
Mounting panel for Ackermann floor box GESR 2
WAXWSU-00100-C001
Features
Ordering Information
Units per
Order Number Description Delivery
WAXWSU-00400-C001 Mounting Panel for Ackermann 1/1
Floor Boxes GES 2, GES 4, GES 4/10,
GESR 4, GES 6, GES 6/10, GESR 7/10
(only center position) or GES 8/10
for the installation of 2 LANscape
housings (WAXWSE-V0201-C002 or
CAXCSE-V0201-C001),
high-grade steel
Ordering Information
Blank Cover Panel
Introduction
Order Number Description Delivery
FutureCom F
WAXWSU-00000-C001 Blank Cover Panel for unused 1/1
mounting positions, suitable
for Ackermann and Kleinhuis
FutureCom 10TEN
mounting panels (page 150),
metal, high-grade steel
FutureCom E
FutureCom D
Installation Options
FutureCom UD FutureCom UE
WAXWSU-00600-C002
1. Blank Cover
WAXWSU-00000-C001
Hardware
CAXCSE-V0201-C001
CAXGSM-00100-C001
and one gray S/FTP flex/26 patch cord
CCAEGB-G1002-A020-C0
and one MT-RJ fiber optic module
Special
Cable
LAXLSM-00101-C004
Information
Further
Ordering Information
Units per
Order Number Description Delivery
WAXWSV-02400-C001 19“ Patch Panel, 1/1
for max. 24 LANscape®
fiber optic or FutureCom™
copper modules, with
integrated cable strain
relief, 1 U,
high-grade steel
Ordering Information
Introduction
Units per
Order Number Description Delivery
19“ Blank Panel,
to fill unused areas
FutureCom F
in the distribution cabinet
or rack,
high-grade steel
FutureCom 10TEN
WAXWSW-00000-C004 1U 1/1
WAXWSW-00000-C005 2U 1/1
FutureCom E
FutureCom D
WAXWSW-00000-C007 19“ Cable Management 1/1
FutureCom UD FutureCom UE
Panel, 1 U, high-grade steel
front panel with 5 black
cable management
brackets
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Ordering Information
Units per
Order Number Description Delivery
WAXWSV-02408-C001 19“ Patch Panel, 1/1
for max. 24 LANscape®
fiber optic or FutureCom™
copper modules, with
integrated cable strain
relief, 1 U,
black
Ordering Information
Introduction
Units per
Order Number Description Delivery
19“ Blank Panel,
to fill unused areas
FutureCom F
in the distribution
cabinet or rack,
black
FutureCom 10TEN
WAXWSW-00008-C004 1U 1/1
WAXWSW-00008-C005 2U 1/1
FutureCom E
FutureCom D
WAXWSW-00008-C007 19“ Cable Management 1/1
FutureCom UD FutureCom UE
Panel,1 U, black
front panel with 5 black
cable management
brackets
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Ordering Information
Features
Introduction
Full metal housing for up to 12 LANscape® fiber optic
or copper modules
Conforms to standards ISO/IEC 11801 (2002) and
EN 50173-1 (2003)
FutureCom F
Ideally suited for a distribution or consolidation point
Suitable for ceiling, wall, false floor or desk mounting
Individual strain relief for incoming and outgoing cables
FutureCom 10TEN
Dust-proof feedthrough for incoming cables
Easy plug-in of consolidation point cables (dust protec-
tion and mechanical protection)
Housing floor electrically conductive for optimal
FutureCom E
shielding transition or grounding
Installation height of 60 mm
Fastening of the housing top with non-detachable screws
FutureCom D
Black sheet steel housing top, RAL 9005, white labeling
Ordering Information
FutureCom UD FutureCom UE
Units per
Order Number Description Delivery
WAXWSW-00008-C015 Consolidation Point 1/1
Housing for max.
12 LANscape modules,
Hardware
with cable strain relief
for incoming data
cable, patch cord strain
Description
Ordering Information
Units per
Order Number Description Delivery
CAXCSN-00000-C005 Assembly Toolkit for FutureCom Modules 1/1
1 2 3
4 5 6 7 8 9 10 11 12
13
14 15
Introduction
Description Application
1. Crimping Tool Assembly of additional cable strain relief for S100e, S100eL and S250 Modules
2. Module Tool Assembly of the basic modules with wire management
for S10TEN, S100e, S100eL and S250 Modules
FutureCom F
3. S1200 Installation Tool Tool for stripping cable, trimming PiMF foil and preparing the pairs of S1200
modules or connectors
4. Screwdriver for Slotted Screws, Size 4 Universal
FutureCom 10TEN
5. Screwdriver for Cross Slotted Screws, Size 1 Universal
6. Edge-cutter Universal
7. Electronics Edge-Cutter, 125 mm Universal
8. Waterproof Pen, white Marking
FutureCom E
9. Waterproof Pen, black Marking
10. Telephone Scissors, 130 mm Universal
11. Open-Ended Wrench, size 8 x 10 Hexagon head bolts/nuts, size 8 x 10
FutureCom D
12. Tape Measure, 1.4 m long Universal
13. Copper Conducting Tape, 12.7 mm wide, Module installation (terminating braid shield)
16.5 m
14. Steel Ruler, 300 mm long Universal
FutureCom UD FutureCom UE
15. “Jokari” Stripping Knife Cutting cable sheath
16. Installation Instructions Assembly of S1200/S250/S250fx/U250/U250fx/S100eL/S100e/U100e Modules
Ordering Information
Hardware
Units per
Order Number Description Delivery
CAXCSN-00000-C004 Copper Conducting Tape, 12.7 mm wide, 1/1
Ordering Information
Ordering Information
Introduction
Assembly Tool for Modules
Units per
Order Number Description Delivery
FutureCom F
CAXCSN-00000-C007 Assembly Tool, 1/1
for connecting
the basic modules
FutureCom 10TEN
with the wire
management for
FutureCom™ S10TEN,
S10TEN fx, S250, S250fx,
FutureCom E
U250, U250fx, S100eL,
S100e, U100e modules
FutureCom D
FutureCom UD FutureCom UE
Crimping Pliers for Additional Strain Relief
Units per
Order Number Description Delivery
CAXCSN-00000-C002 Crimping Pliers for die assembly 1/1
Hardware
of the additional cable strain relief
for the FutureCom™ S10TEN,S10TEN fx,
S250, S250fx, U250, U250fx, S100eL,
Description Features
Corning Cable Systems IDC terminal strips provide a reliable High density
and effective wire connection for telecommunications and User-friendly cable managment through wire guides
data networks at very high density. Our strips can be moun- High felxibility due to adaptability of different wire
ted in 19“ panels or IDC blocks, for direct connectorization, guides
with punch down tool. The IDC terminal strips offer a very Multiple access wire guiding of incoming wires
high density with a height of only 13.8 mm including wire (e.g. system cable to be terminated on upper row of IDC
guides. They are easy to install and maintain. Userfriendly contacts) is possible from either rear or left or right hand
cable management supports longterm control over chang- side.
ing jumpering. Multiple access wire guiding of outgoing wires (to be
terminated on lower row of IDC contacts) is possible
from either left or right hand side
All combinations possible and available on request
Suitable for conductor size AWG 22-28
Ordering Information
IDC Disconnection Terminal Strips
Units per
Order Number Description Delivery
Cable side from the right,
jumper side from the left
C39104-A123-A10 numbered, white 10 pairs
C39104-A123-A11 numbered, white 10 pairs
C39104-A123-A12 numbered, white 10 pairs
C39104-A123-A13 numbered, white 10 pairs
Ordering Information
Introduction
Units per
Order Number Description Delivery
19“ Solutions
C39393-A80-D53 Horizontal 19“ Rack (empty) for Series 1000RT IDC terminal strips, 1
FutureCom F
IDC terminal strips ordered separately (max. 28 terminal strips; 280 pairs)
C39393-A80-D52 Horizontal 19“ bracket to install Series 1000RT mounting frames, 1
2 pcs. required, mounting frames and IDC terminal strips ordered
FutureCom 10TEN
separately
C39104-A123-B69 20-way mounting frames with closed jumper comb (length = 321 mm), 1
4 pcs. required to install 20 terminal strips
* different sizes of mounting and full cablinet frames also available
FutureCom E
Overvoltage / Overcurrent Terminal Strips Protection
S30264-D1006-S210 Overvoltage (3-point) 230 V + 20 %, with fail safe 1
FutureCom D
S30264-D1006-S211 Overvoltage / Overcurrent (5-Point), 230 V + 20 %, with fail safe, 150 mA / PTC 1
* single pair protector also available
FutureCom UD FutureCom UE
C39195-A332-A12 Patch cord 1 x 1000RT to 1 x 1000RT, 2 meters 1
C39195-A332-A31 Patch cord 1 x 1000RT to 1 x RJ45, 2 meters 1
C39195-A332-A30 Patch cord 2 x 1000RT to 1 x RJ45, 2 meters 1
Hardware
Marking Accessories
C39104-A115-C50 Color black 10 caps
C39104-A115-C51 Color white 10 caps
Termination Tools
Industrial
Cable
C39407-A139-A12 Termination Tool for connecting the wires, cutting device with lock for 1
optional cutting of excess wire length and extraction hook for removing wires
C39407-A149-A15 Extraction Tool for removing modules out of extremely narrow distribution 1
Special
enclosures
Cable
Labeling Kits
Information
Features
Ordering Information
Units per
Order Number Description Delivery
CAXCSV-05003-C001 FutureCom™ Cat. 3/ISDN 1/1
Telephone Patch Panel,
unshielded, 50xRJ45,
configuration 4.5 and
3.6, LSA-PLUS, 1U,
light-basic, RAL 7035
Features
Introduction
19“ patch panel 1U and 0.5U with 25 unshielded 8-pin RJ 45
jacks
Wire connection via 8-pin LSA/110 connect dual cutting
clamps for AWG 22-26
FutureCom F
Wiring according to ISO/IEC 11801/EN 50173-1,
configuration: Pin 3/6 and Pin 4/5
Grounding via M6 screw with nut and lock washer on the
FutureCom 10TEN
patch panel
Shield connection directly on the circuit board
Integrated cable strain relief
FutureCom E
Ordering Information
FutureCom D
Units per
Order Number Description Delivery
CAXCSV-02503-C001 FutureCom™ Cat. 3/ISDN 1/1
FutureCom UD FutureCom UE
Telephone Patch Panel,
unshielded, 25xRJ45,
configuration 4.5 and
3.6, LSA-PLUS, 1U,
light-basic, RAL 7035
Hardware
ISDN Products
Telephone /
CableCable
Cord Cord
unshielded, 25xRJ45,
configuration 4.5 and
3.6, LSA-PLUS, 1U,
Industrial
high-grade steel
Cable
Special
Cable
Information
Further
Ordering Information
Units per
Order Number Description Delivery
CAXCSV-02503-C002 FutureCom™ Cat. 3/ISDN 1/1
Telephone Patch Panel,
unshielded, 25xRJ45,
configuration 4.5 and
3.6, LSA-PLUS, 0.5U,
light-basic, RAL 7035
Application
Braided shield FutureCom™ S/FTP flex/26 patch cord cable is designed for
applications up to 600 MHz and its transmission character-
Halogen-free jacket,
flame retardant istics satisfy Category 7 specifications.
Foil shielding (PiMF) FutureCom patch cord cables are a low-skew product, i.e. the
skew between the individual pairs is very low. This is increas-
Twisted pair
ingly required for applications above 1 Gigabit. The cable has
PE foam-skin insulation a streamlined construction and low weight.
4 shielded pairs
Each pair is individually shielded (PiMF). The stranded pairs
Copper flex wire, are additionally braid shielded (S/FTP), which guarantees
AWG 26 outstanding shielding characteristics. The cable satisfies the
standards of Class B interference radiation (EN 55022), as
well as immunitiy (EN 55024), which enables the realization
of CE-compatible networks.
Introduction
Largest resistance margin 2%
Insulation resistance >5000 MV x km
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
Impedance Zo at 101 - 250 MHz 100 V +/- 18%
FutureCom F
Impedance Zo at 251 - 600 MHz 100 V +/- 25%
Surface transfer impedance 10 m V/m
(typical value) at 10 MHz
FutureCom 10TEN
Operating capacity 43 pF/m
Propagation velocity 0.78 x c
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz 4.3 ns/m
FutureCom E
Delay skew 4 ns/100 m
FutureCom D
Frequency in MHz 1 10 20 31.25 62.5 100 300 600
Attenuation in dB/100m * 2.9 8.5 12.1 15.2 21.7 27.8 50.0 73.3
FutureCom UD FutureCom UE
Typical values dB/100m 2.9 7.9 10.8 13.5 19.5 25.2 44.3 63.5
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m 96.0 96.0 96.0 96.0 95.0 94.0 86.0 80.0
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Typical values in dB at 100m 93.0 93.0 93.0 93.0 92.0 91.0 83.0 77.0
ELFEXT in dB at 100 m * 80.0 74.0 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 95.0 93.0 93.0 88.0 81.0 72.0 60.0 51.0
PSELFEXT in dB at 100 m * 77.0 71.0 65.0 61.1 55.1 51.0 41.5 35.4
Hardware
Typical values in dB at 100m 92.0 90.0 90.0 85.0 78.0 69.0 57.0 48.0
ACR in dB 93.1 88.1 85.2 82.5 75.5 68.8 41.7 16.5
Ordering Information
Fire Load Zero Outer [ Weight Length
Type designation Category Pair count (MJ/m) Halogen Color (mm) (kg/km) (m) Order Number
Industrial
Cable
Application
Braided shield
The FutureCom™ SF/UTP flex/26 patch cord cable is
Halogen-free jacket, specified for applications up to 300 MHz and it´s outstand-
flame retardant ing transmission characteristics satisfy Channel D (2002)
specifications.
Foil shield
Twisted pair FutureCom patch cord cables are low-skew products. This is
increasingly required for applications above 1 Gigabit. The
PE foam-skin insulation cable has a streamlined construction and low weight.
4 shielded pairs
The stranded pairs are foil shielded and have a braided
Copper flex wire, shield (SF/UTP), which guarantees outstanding shielding
AWG 26
characteristics. The cable satisfies the standards for Class B
interference radiation (EN 55022), as well as immunity
(EN 55024), which enables the realization of CE-compatible
networks.
Introduction
Largest resistance margin 3%
Insulation resistance >150 MV x km
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
Surface transfer impedance <100 m V/m
FutureCom F
(typical value) at 10 MHz
Operating capacity 48 pF/m
Propagation velocity 0.74 x c
FutureCom 10TEN
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz 4.5 ns/m
Delay skew 7 ns/100 m
FutureCom E
Frequency in MHz 1 10 16 20 31.25 62.5 100 300
FutureCom D
Attenuation in dB/100m * 3.2 6.0 9.5 13.6 17.1 24.8 32.0
Typical values dB/100m 3.0 5.8 9.0 12.2 14.7 22.5 27.3 48.3
–
FutureCom UD FutureCom UE
–
Hardware
* Standard: Requirements for Category 5/5e flexible cable (conforms with EN-50288-2-2)
–
Application
Conductor insulation Halogen free S/FTP 600/23 PUR cable, specified up to 800 MHz
Foam-skin material Outstanding electrical characteristics
Outer jacket Polyurethane Each pair is shielded (PiMF)
Area/range of application Dry and Full copper braid shield
damp rooms Streamlined design
Temperature range (installation) 0 to +50°C Lightweight
Operating temperature -20 to +60°C Low skew between the pairs
Min. bending radius >_ 40 mm Halogen-free (LSZH)
for one-time bending Flame resistant and non-corrosive
Min. bending radius during >_ 60 mm Lubricant-resistant, microbe-resistant and hydrolysis-
installation resistant
Copper conductor AWG 23
Introduction
Largest resistance margin 1%
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/- 20%
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/- 18%
Impedance Zo at 251 - 600 MHz 100 V +/- 25%
Surface transfer impedance <10 m V/m at 10 MHz
FutureCom 10TEN
Unbalance to ground >46 dB at 64 kHz
dB/BZL = 1000 m
Unbalance to ground >40 dB at 1 MHz
dB/BZL = 100 m
FutureCom E
Unbalance to ground >20 dB at 100 MHz
dB/BZL = 100 m
Propagation velocity 0.79 x c
at >10 MHz (NVP x c)
FutureCom D
Propagation delay >_ 10 MHz 4.2 ns/m
Delay skew 4 ns/100 m
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 300 600 800
Attenuation in dB/100m* 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.9 30.7 44.0 53.0
–
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 95.0 91.0 87.0
–
PSNEXT in dB at 100 m* 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Hardware
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 98.0 97.0 93.0 89.0 85.0
–
ELFEXT in dB at 100 m* 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
–
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 82.1 64.3 47.0 34.0
–
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Ordering Information
Industrial
Cable
Max
Fire Load Zero Tensile Outer [ Weight Length
Type designation Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number
Special
Cable
Application
Halogen-free jacket,
flame retardant The FutureCom™ 120 V Industrial Cable is designed
specifically for data and voice transmission in industrial or
Star Quad telecommuncations enviroments. These cables can be used
Foil shielding as connecting cables or for direct installation in dry as well
PP foil as damp rooms.
Dummy element
Braid shield
Additional wire
Foam-skin insulation
Copper conductor
AWG 24
Introduction
Typical values in dB/100 m 1.5 1.75 3.3 4.9 6.8 7.6
Typical values in dB at 100 m, Cable 61.5 58.9 47.2 40.3 36.9 34.7
Typical values in dB at 100 m, Quad 66 65.8 53.0 44.3 42.4 41.2
FutureCom F
Electrical Characteristics (at 20°C)
FutureCom 10TEN
Insulation resistance $ 10 GV x km
Impedance Zo at 0.064 MHz 120 V +/- 15V
NEXT at 1 MHz
FutureCom E
End to end in the same quad $ 50 dB
End to end in different cables (2x60m) $ 75 dB
ELFEXT at 1 MHz
End to end in the same quad $ 50 dB
FutureCom D
End to end in different cables (2x60m) $ 75 dB
Max. attenuation at 1 MHz # 19 dB/1000m
Shield attenuation (30 to 900 MHz) $ 80 dB
FutureCom UD FutureCom UE
Operating Voltage 300 Vss
Testing Voltage 800 Vss
(conductor/conductor, conductor/
shielding at 50 Hz, 1 min)
Ordering Information
Hardware
Zero Outer[ Weight Length
Type designation Category Pair count Halogen mm (kg/km) (m) Order Number
Application
4 shielded pairs Each pair is individually shielded (PiMF). The stranded pairs
are additionally sheathed with a braid shield (S/FTP), which
Copper flex wire guarantees outstanding shielding characteristics. The cable
AWG 26
satisfies Class B interference radiation standards (EN 55022),
as well as immunity (EN 55024), which enables the realiza-
tion of CE-compatible networks.
Introduction
Largest resistance margin 2%
Insulation resistance >5000 MV x km
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
Impedance Zo at 101 - 250 MHz 100 V +/- 18%
FutureCom F
Impedance Zo at 251 - 600 MHz 100 V +/- 25%
Surface transfer impedance <10 m V/m at 10 MHz
Operating capacity 43 pF/m
FutureCom 10TEN
Propagation velocity at >10 MHz 0.78 x c
Propagation delay >_ 10 MHz 4.3 ns/m
Delay skew 4 ns/100 m
FutureCom E
Frequency in MHz 1 10 20 31.25 62.5 100 300 600
Attenuation in dB/100m* 2.9 8.5 12.1 15.2 21.7 27.8 50.0 73.3
FutureCom D
Typical values dB/100m 2,9 7.9 10.8 13.5 19.5 25.2 44.3 63.5
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m 96.0 96.0 96.0 96.0 95.0 94.0 86.0 80.0
FutureCom UD FutureCom UE
PSNEXT in dB at 100 m* 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Typical values in dB at 100m 93.0 93.0 93.0 93.0 92.0 91.0 83.0 77.0
ELFEXT in dB at 100 m* 80.0 74.0 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 95.0 93.0 93.0 88.0 81.0 72.0 60.0 51.0
PSELFEXT in dB at 100 m* 77.0 71.0 65.0 61.1 55.1 51.0 41.5 35.4
Typical values in dB at 100m 92.0 90.0 90.0 85.0 78.0 69.0 57.0 48.0
ACR in dB 93.1 88.1 85.2 82.5 75.5 68.8 41.7 16.5
* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)
Hardware
Ordering Information
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
12 Special Cable
Introduction
12.1. F/UTP 450/23 FRNC Cable 184
FutureCom F
12.2.1. S/FTP 600/23 with Diffusion Barrier 186
FutureCom 10TEN
12.2.2. U/UTP 100/24 190
FutureCom E
12.3.2. Fiber Blow S/FTP 600 194
FutureCom D
12.4. ViMF Cable
FutureCom UD FutureCom UE
12.4.2. Star Quad U/FTP 300/23 FRNC 200
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
Application
Foil shielding FutureCom cables are low-skew products, i.e. the skew
between the individual pairs is very low. This is increasingly
Foil shielding required for applications above 1 Gigabit-Ethernet. These
PE foam-skin The four stranded pairs are foil shielded (F/UTP). The cable
insulation
satisfies Class B interference radiation standards (EN 55022)
Additional wire as well as immunity (EN 55024) which enables the realiza-
tion of CE-compatible networks.
Central cross member
Copper conductor
AWG 23
Introduction
Frequency in MHz 1 10 16 20 31.25 62.5 100 250
Attenuation in dB/100m per Standard * 2.1 6.0 7.6 8.5 10.7 15.5 19.9 33.0
Near-end crosstalk loss in DB per Standard * 66.0 59.3 56.2 54.8 51.9 47.4 44.3 38.3
FutureCom F
PSNEXT in dB at 100 m per Standard * 64.0 57.3 54.2 52.8 49.9 45.4 42.3 36.3
ELFEXT in dB at 100 m per Standard * 66.0 50.0 45.9 44.0 40.1 34.1 30.0 22.0
PSELFEXT in dB at 100 m per Standard * 64.0 47.0 43.0 41.0 37.1 31.1 27.0 19.0
FutureCom 10TEN
ACR in dB 63.9 53.3 48.6 46.3 41.2 31.9 24.4 5.3
* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling links (conforms with EN 50288-5-1)
FutureCom E
Ordering Information
Max.
Tensile
FutureCom D
Fire Load Zero Strength Outer[ Weight Length
Type designation Category Pair count (MJ/m) Halogen (N) mm (kg/km) (m) Order Number
FutureCom UD FutureCom UE
Hardware
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Industrial
Cable
Special
Cable
Information
Further
Application
PE sheath
Layered aluminum The FutureCom™ S/FTP 600/23 data cable with diffusion
band barrier is specified up to 800 MHz. It’s transmission
Braided shield characteristics satisfy Category 7 specifications according to
ISO/IEC 11801 (2002) and EN 50173-1 (2003).
Twisted pair
FutureCom cables are low-skew products, i.e.the skew
Foil shielding (PiMF) between the individual pairs is very low. As a result of the
aluminum composite layer sheath, this cable is suitable for
PE foam-skin
insulation direct burial. The cable has a streamlined construction and
Copper conductor low weight.
AWG 23
Each pair is individually shielded (PiMF). The stranded pairs
FRNC interior sheath
are sheathed with a braided shield (S/FTP), which guaran-
4 shielded pairs tees outstanding shielding characteristics. The cable satis-
fies the standard for Class B interference radiation
(EN 55022), as well as immunitiy (EN 55024), which enables
the realization of CE-compatible networks.
Conductor insulation Halogen free/ S/FTP 600/23 cable, specified up to 800 MHz
foam-skin material Outstanding electrical characteristics
Outer jacket Halogen free Each pair is shielded (PiMF)
Area/range of application Outdoor installation Full copper braid shield
Temperature range (installation) 0 to +50°C Streamlined design
Operating temperature -20 to +60°C Lightweight
Min. bending radius <_ 175 mm Low skew between the pairs
for one-time bending Includes a diffusion barrier
Min. bending radius during <_ 235 mm (aluminum band and PE sheath)
installation Halogen-free (LSZH)
Copper conductor AWG 23 Interior sheath flame retardant according to
IEC 60332-3 and EN 50266-2-4
Interior sheath non-corrosive according to
IEC 60754-2 and EN 50267
Interior sheath low smoke according to IEC 61034
Can be directly buried
Introduction
Largest resistance margin 1%
Insulation resistance > 5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/- 20%
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/- 18%
Impedance Zo at 251 - 600 MHz 100 V +/- 25%
Surface transfer impedance <10 m V/m at 10 MHz
FutureCom 10TEN
Unbalance to ground >46 dB at 64 kHz
dB/BZL = 1000 m
Unbalance to ground >40 dB at 1 MHz
dB/BZL = 100 m
FutureCom E
Unbalance to ground >20 dB at 100 MHz
dB/BZL = 100 m
Propagation velocity 0.79 x c
at >10 MHz (NVP x c)
FutureCom D
Propagation delay >_ 10 MHz 4.2 ns/m
Delay skew 4 ns/100 m
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 300 600 800
Attenuation in dB/100m * 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.9 30.7 44.0 53.0
–
NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 95.0 91.0 87.0
–
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Hardware
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 98.0 97.0 93.0 89.0 85.0
–
ELFEXT in dB at 100 m * 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
–
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 82.1 64.3 47.0 34.0
–
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Ordering Information
Industrial
Cable
Max
Fire Load Zero Tensile Outer [ Weight Length
Type designation Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number
Special
Cable
Application
Foil shielding
The FutureCom™ F/UTP 300/24 PE cable is designed for out-
PE-outer sheath
door applications up to 300 MHz and provides transmission
2 wires stranded to a performance exceeding Category 5e ISO/IEC 11801 (2002)
pair and EN 50173-1 (2003) specifications.
Foil shielding
The improved operating temperature of up to -60°C is
Additional wire appropriate for the use under most adverse conditions.
This cables are low skew products, i.e. the difference in prop-
PE foam-skin PE
agation delay between the individual pairs is
insulation
very low. This is increasingly being requested for Gigabit
Copper conductor Ethernet. The cable as a streamlined construction and low
AWG 24 weight.
4 shielded pairs
The stranded pairs are surrounded by foils (F/UTP).
The cable satisfies Class B interference radiation
Color Coding (EN 55022), as well as immunity (EN 55024), which enables
the realization of CE-compatible networks.
Pair 1 White with blue rings/blue
Pair 2 White with orange rings/orange
Pair 3 White with green rings/green
Pair 4 White with brown rings/brown
Wire insulation Halogen free F/UTP 300/24 PE cable, specified up to 300 MHz
PE foam-skin material Outdoor cable specified up to -60°C
Sheath material PE Excellent electrical characteristics
Area/range of application Outdoor installation Full shielding including 2 foils with additional tinned
Temperature range (in motion) 0 to +50°C copper wire
Operating temperature -60 to +60°C Slim design
Min. bending radius >35 mm Lightweight
for one-time bending Low skew between the pairs
Min. bending radius >50 mm PE jacket
during installation
Diameter of the copper conductor AWG 24
Introduction
Largest resistance margin 2%
Insulation resistance >5000 MV x km
DC resistance 185 V/km
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Surface transfer impedance <10 m V/m at 10 MHz
Unbalance to ground >46 dB at 64 kHz
dB/BZL = 1000 m
FutureCom 10TEN
Unbalance to ground >40 dB at 1 MHz
dB/BZL = 100 m
Unbalance to ground >20 dB at 100 MHz
dB/BZL = 100 m
FutureCom E
Propogation velocity 0.74 * c
at >10 MHz (NVP * c)
Signal delay >10 MHz 4.5 ns/m
Delay margin 7 ns/100 m
FutureCom D
Frequency in MHz 1 10 16 20 31.25 62.5
FutureCom UD FutureCom UE
100 250 300
Attenuation in dB/100m according to standard* 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 2.0 5.6 7.2 8.0 10.1 14.4 18.2 29.5 32.2
– –
NEXT in dB at 100 m to standard* 65.3 50.3 47.3 45.8 42.9 38.4 35.3
Typical values in dB at 100m 77.0 62.0 59.0 57.0 54.0 50.0 46.0 38.5 35.0
– –
PSNEXT in dB at 100 m according to standard* 62.3 47.3 44.2 42.8 39.9 35.4 32.3
Typical values in dB at 100m 75.0 60.0 57.0 55.0 52.0 48.0 44.0 36.5 33.0
– –
ELFEXT in dB at 100 m according to standard* 63.8 43.8 39.7 37.8 33.9 27.9 23.8
Hardware
Typical values in dB at 100m 72.0 60.0 54.0 52.0 48.0 40.0 34.0 22.1 17.0
– –
PSELFEXT in dB at 100 m according to standard* 60.8 40.8 36.7 34.8 30.9 24.9 20.8
Typical values in dB at 100m 70.0 58.0 52.0 50.0 46.0 38.0 32.0 20.1 15.0
– –
ACR in dB 74.9 55.9 51.4 48.5 43.5 34.9 26.7 7.0 0.9
Ordering Information
Max Std.
Zero Min. Tem- Tensile Outer [ Weight Length
Industrial
Type designation Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m) Order Number
Cable
Application
PE-outer jacket
The FutureCom™ U/UTP 100/24 PE cables are designed for
2 wires stranded to a
pair outdoor applications up to 100 MHz and provides transmis-
sion performance exceeding Category 5e ISO/IEC 11801
PE foam-skin PE (2002) and EN 50173-1 (2003) specifications. The improved
insulation
operating temperature of up to -60°C/-40°C is appropriate
4 unshielded pairs for the employment under most, even adverse, conditions.
Copper conductor This cables are low skew products, i.e. the difference in prop-
AWG 24
agation delay between the individual pairs is very low. This
is increasingly being requested for e.g. Gigabit Ethernet.
The cable has a streamlined construction and low weight.
Color Coding
The cable satisfies Class B interference radiation (EN 55022),
Pair 1 White with blue rings/blue as well as immunity (EN 55024), which enables the
Pair 2 White with orange rings/orange realization of CE-compatible networks.
Pair 3 White with green rings/green
Pair 4 White with brown rings/brown
Introduction
Largest resistance margin 3%
Insulation resistance >5000 MV x km
DC resistance 185 V/km
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Mutual capacity 45 pF/m
Propogation velocity 0.74 x c
at >10 MHz (NVP * c)
FutureCom 10TEN
Signal delay >10 MHz 4.5 ns/m
Delay margin 7 ns/100 m
FutureCom E
Frequency in MHz 1 10 16 20 31.25 62.5 100
Attenuation in dB/100m according to standard* 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 1.9 5.9 7.4 8.4 10.5 15.1 19.3
FutureCom D
NEXT in dB at 100 m to standard* 65.3 50,3 47,3 45,8 42,9 38.4 35.3
Typical values in dB at 100m 77.4 65.5 62.2 59.7 57.7 49.6 46.6
PSNEXT in dB at 100 m according to standard* 62.3 47.3 44.2 42.8 39.9 35.4 32.3
Typical values in dB at 100m 74.0 60.0 56.0 54.0 51.0 47.0 44.0
FutureCom UD FutureCom UE
ELFEXT in dB at 100 m according to standard* 63.8 43.8 39.7 37.8 33.9 27.9 23.8
Typical values in dB at 100m 68.0 49.0 45.0 42.0 40.0 33.0 28.0
PSELFEXT in dB at 100 m according to standard* 60.8 40.8 36.7 34.8 30.9 24.9 20.8
Typical values in dB at 100m 66.0 47.0 43.0 40.0 38.0 31.0 26.0
ACR in dB 74.1 56.1 50.6 47.6 42.5 33.9 26.7
*Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-3-1)
Hardware
Ordering Information
for Patch Cord ISDN Products
Flex Wire Cable Telephone /
Max Std.
Zero Min. Tem- Tensile Outer [ Weight Length
Type designation Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m) Order Number
Application
Braided shield
The FutureCom™ S/FTP 900/23 fiber blow is prepared for the
Halogen-free jacket,
subsequent insertion of up to 12 fibers (single or multimode
flame retardant
fibers with 250 µm diameter can be inserted). Future-proof
Twisted pair cabling, for example fiber-to-the-desk (FTTD), can be easily
realized. The integrated copper data cable is specified for ap-
Foil shielding (PiMF) plications up to 1000 MHz and its transmission characteris-
tics satisfy Category 7 specifications according to ISO/IEC
4 shielded pairs
11801 (2002) and EN 50173-1 (2003).
PE foam-skin insulation
FutureCom cables are low-skew products, i.e. the skew
Copper conductor
AWG 23 between the individual pairs is very low. This is increasingly
required for applications above 1 Gigabit. The cable has a
Tube for streamlined construction and low weight. Each pair is
insertion of fibers individually shielded (PiMF). The stranded pairs are sheathed
with a braided shield (S/FTP), which guarantees outstanding
shielding characteristics. The cable satisfies the standards
for Class B interference radiation (EN 55022), as well as
immunity (EN 55024), which enables the realization of
CE-compatible networks.
Introduction
Largest resistance margin 1%
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/- 20%
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/- 18%
Impedance Zo at 251 - 600 MHz 100 V +/- 25%
Surface transfer impedance <10 m V/m at 10 MHz
FutureCom 10TEN
Unbalance to ground >46 dB at 64 kHz
dB/BZL = 1000 m
Unbalance to ground >40 dB at 1 MHz
dB/BZL = 100 m
FutureCom E
Unbalance to ground >20 dB at 100 MHz
dB/BZL = 100 m
Propagation velocity 0.79 x c
at >10 MHz (NVP x c)
FutureCom D
Propagation delay >_ 10 MHz 4.2 ns/m
Delay skew 4 ns/100 m
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 300 600 900 1000
Attenuation in dB/100m* 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.8 30.0 42.5 55.0 59.0
– –
NEXT in dB 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 92.0 86.0 83.0
– –
PSNEXT in dB at 100 m* 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Hardware
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0 90.0 84.0 81.0
– –
ELFEXT in dB at 100 m* 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
– –
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 31.0 24.0
– –
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Industrial
Cable
Ordering Information
Max
Special
Cable
Fiber Blow
Application
Braided shield
The FutureCom™ S/FTP 600/23 fiber blow is prepared for the
Halogen-free jacket, subsequent insertion of up to 12 fibers (single or multimode
flame retardant fibers with 250 µm diameter can be inserted). Future-proof
cabling, for example fiber-to-the-desk (FTTD), can be easily
Twisted pair realized. The integrated copper data cable is specified for ap-
plications up to 800 MHz and its transmission characteris-
Foil shielding (PiMF)
tics satisfy Category 7 specifications according to ISO/IEC
4 shielded pairs 11801 (2002) and EN 50173-1 (2003).
PE foam-skin insulation FutureCom cables are low-skew products, i.e. the skew
Copper conductor between the individual pairs is very low. This is increasingly
AWG 23 required for applications above 1 Gigabit. The cable has a
Tube for streamlined construction and low weight. Each pair is indi-
insertion of fibers vidually shielded (PiMF). The stranded pairs are sheathed
with a braided shield (S/FTP), which guarantees outstanding
shielding characteristics. The cable satisfies the standards
for Class B interference radiation (EN 55022), as well as
immunity (EN 55024), which enables the realization of
CE-compatible networks.
Conductor insulation Halogen free Fiber blow S/FTP 600/23 cable, specified up to 800 MHz
foam-skin material Outstanding electrical characteristics
Outer jacket Halogen free Each pair is individually shielded with foil
flame retardant Full copper braid shield
Area/range of application Dry and Low skew between the pairs
damp rooms Prepared for the subsequent insertion of up to 12 fibers
Temperature range (installation) 0 to +50°C Halogen-free (LSZH)
Operating temperature -20 to +60°C Flame retardant according to IEC 60332-3, Category C
Min. bending radius >_ 100 mm Non-corrosive according to IEC 60754-2 (FRNC)
for one-time bending (over flat side*) Low smoke according to IEC 61034
Min. bending radius during >_ 100 mm
installation (over flat side*)
Copper conductor AWG 23
* Max. cabling length of 90 m with 12 x 90° bends with
regard to a radius of 100 mm
Introduction
Largest resistance margin 1%
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/- 20%
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Impedance Zo at 101 - 250 MHz 100 V +/- 18%
Impedance Zo at 251 - 600 MHz 100 V +/- 25%
Surface transfer impedance <10 m V/m at 10 MHz
FutureCom 10TEN
Unbalance to ground >46 dB at 64 kHz
dB/BZL = 1000 m
Unbalance to ground >40 dB at 1 MHz
dB/BZL = 100 m
FutureCom E
Unbalance to ground >20 dB at 100 MHz
dB/BZL = 100 m
Propagation velocity 0.79 x c
at >10 MHz (NVP x c)
FutureCom D
Propagation delay >_ 10 MHz 4.2 ns/m
Delay skew 4 ns/100 m
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 300 600 800
Attenuation in dB/100m * 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.8 30.0 42.5 53.0
–
NEXT in dB 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 92.0 87.0
–
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Hardware
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0 90.0 85.0
–
ELFEXT in dB at 100 m * 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
–
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
–
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 34.0
–
* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Ordering Information
Industrial
Cable
Max
Fire Load Zero Tensile Outer [Weight Length
Special
Type designation Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number
Cable
Application
Braided shield
PE foam-skin insulation adapter cables and for connecting workstations inside build-
ings (FTTD - Fiber-to-the-Desk). They can also be used as in-
Copper conductor AWG 23 ter-building connecting cables in dry conduits. The 900µm
Halogen-free jacket, tight-buffer design allows easy and direct field connector-
flame retardant
ization.
Rip-cord
The FutureCom™ S/FTP 600/23 copper cable is specified for
900 µm tight buffered fiber
applications up to 800 MHz and its transmission character-
Fiber istics satisfy Category 7 specifications according to ISO/IEC
Strain relief 11801 (2002) and EN 50173-1 (2003). A high level of system
(aramide yarn) performance for the complete channel is achieved by using
this high-quality Category 7 cable.
FO cable with 900µm tight-buffered fibers, S/FTP 600/23 cable, specified up to 800 MHz
TB-3 construction enables easy, consistent stripping Outstanding electrical characteristics
Particularly suitable for field-installable UniCam® Each pair is individually shielded with foil
connectors Full copper braid shield
Telecordia color-coding Low skew between the pairs
Completely dry construction Halogen-free (LSZH)
Flame retardant according to IEC 60332-3, Category C
Non-corrosive according to IEC 60754-2 (FRNC)
Low smoke according to IEC 61034
Introduction
Typ. attenuation Typ. attenuation Guaranteed mini-
Loose Tube in the tight buffer mum distance at
Fiber Type Features Cables cable in dB/km
850 nm 1300 nm 850 nm 1300 nm 1 Gbit/s 10 Gbit/s
FutureCom F
InfiniCor® OM2 (50 µm) 2.5 0.7 2.7 0.8 600 m 100 m
FutureCom 10TEN
Largest resistance margin 1%
Conductor insulation Halogen free Insulation resistance >5000 MV x km
foam-skin material Impedance Zo at 0.064 MHz 125 V +/- 20%
Outer jacket Halogen free Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom E
flame retardant Impedance Zo at 101 - 250 MHz 100 V +/- 18%
Area/range of application Dry and Impedance Zo at 251 - 600 MHz 100 V +/- 25%
damp rooms Surface transfer impedance <10 m V/m at 10 MHz
Unbalance to ground >46 dB at 64 kHz
FutureCom D
Temperature range (installation) 0 to +50°C
Operating temperature -20 to +60°C dB/BZL = 1000 m
Min. bending radius >_ 40 mm (for 2x Unbalance to ground >40 dB at 1 MHz
for one-time bending (4x2...) over flat side) dB/BZL = 100 m
FutureCom UD FutureCom UE
Min. bending radius during >_ 60 mm (for 2x Unbalance to ground >20 dB at 100 MHz
installation (4x2...) over flat side) dB/BZL = 100 m
Copper conductor AWG 23 Propagation velocity 0.79 x c
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz 4.2 ns/m
Delay skew 4 ns/100 m
Hardware
Attenuation in dB/100m* 2.0 5.7 7.2 8.1 10.1 14.5 18.5 33.3 48.9
Typical values dB/100m 1.7 5.0 6.5 7.3 9.2 13.2 16.8 30.0 42.5 53.0
–
NEXT in dB 100 m * 80.0 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8
PSNEXT in dB at 100 m * 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 57.8
Typical values in dB at 100m 98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0 90.0 85.0
–
ELFEXT in dB at 100 m * 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 38.4
Typical values in dB at 100m 93.0 93.0 93.0 93.0 90.0 86.0 83.0 68.0 51.0
–
PSELFEXT in dB at 100 m * * 77.0 71.0 66.9 65.0 61.1 55.1 51.0 41.5 35.4
–
Typical values in dB at 100m 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 49.0
–
ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 34.0
–
Industrial
*Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)
Cable
Ordering Information
Max
Special
Cable
J-VH 4G50L/125 + 7 4/4 1.44 Yes 154 7.5x15.5 110 500 WCXWXW-X0087-C001-L6
Further
Application
PE foam-skin insulation StarQuad ViMF Cables are intended for multimedia applica-
tions (voice, image and data communications) where cable
Copper conductor
AWG 22 sharing is an option. Alongside traditional applications
(ISDN, Ethernet and Token Ring), the cables are suitable for
PP foil systems with high frequency areas, such as TPDDI via copper
(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to
1000 Base-T.
Features
Mechanical Characteristics
S/FTP 600/22 cable, specified up to 600 MHz
Conductor insulation Halogen free Outstanding electrical characteristics
foam-skin material Each StarQuad (foursome) is shielded (ViMF)
Outer jacket Halogen free Different color coding of individual foursomes
flame retardant Simultaneous, standard-conforming transmission
Area/range of application Dry and of multiple services is possible
damp rooms Very robust, thus particularly suitable for application in
Temperature range (installation) -5 to +50°C industrial and other harsh environments
Operating temperature -20 to +60°C Full copper braid shield
Min. bending radius >_ 26 mm Zero skew between the foursomes
for one-time bending (over flat side*) Halogen-free (LSZH)
Min. bending radius during >_ 40 mm Flame retardant according to IEC 60332-3, Category C
installation (over flat side*) Non-corrosive according to IEC 60754-2 (FRNC)
Copper conductor AWG 22 Low smoke according to IEC 61034
Introduction
Largest resistance margin 1%
Insulation resistance >5000 MV x km
Impedance Zo at 0.064 MHz 125 V +/- 20%
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
Surface transfer impedance <10 m V/m at 10 MHz
Unbalance to ground >46 dB at 64 kHz
dB/BZL = 1000 m
FutureCom 10TEN
Unbalance to ground >40 dB at 1 MHz
dB/BZL = 100 m
Greatest possible loop resistance 130 V/km
Operating capacity 48 pF/m
FutureCom E
Propagation velocity 0.74 x c
at >10 MHz (NVP x c)
Propagation delay >_ 10 MHz 4.9 ns/m
Delay skew 0 ns/100 m
FutureCom D
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 250 600
Attenuation in dB/100 m * 2.1 6.0 7.6 8.5 10.8 15.5 19.9 33.0
Typical values dB/100m 1.5 4.9 6.3 7.1 9.0 12.9 16.5 26.9 43.6
–
NEXT in dB at 100 m * 66.0 59.3 56.2 54.8 51.9 47.4 44.3 38.3
Typical values in dB at 100 m (pair/pair) 78.6 67.5 64.0 62.0 59.0 54.5 51.8 45.0 38.0
–
Typical values in dB at 100 m (foursome/foursome) 90.0 90.0 90.0 90.0 90.0 90.0 90.0 75.0 70.0
Hardware
PSNEXT in dB at 100 m * 64.0 57.3 54.2 52.8 49.9 45.4 42.3 36.3
Typical values in dB at 100m 75.6 64.5 61.0 59.0 56.0 51.5 48.8 42.0 35.0
–
ELFEXT in dB at 100 m * 66.0 50.0 45.9 44.0 40.1 34.1 30.0 22.0
PSELFEXT in dB at 100m * 64.0 47.0 43.0 41.0 37.1 31.1 27.0 19.0
–
Typical values in dB at 100m 73.0 63.0 60.0 58.0 52.0 42.0 34.0 15.0
–
* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)
–
Industrial
Cable
Ordering Information
Max
Special
Cable
Application
Foil shielding
The FutureCom™ StarQuad ViMF Cable is designed for
Halogen-free applications in industrial and other harsh environments up
jacket to 300 MHz and its transmission characteristics satisfy
Foil shielding Category 5 specifications according to ISO/IEC 11801 (2002)
and EN 50173-1 (2003).
1 twisted
quad
FutureCom ViMF Cables are zero-skew products. i.e. the
Additional skew between the individual pairs of foursomes is very low.
wire This is increasingly required for Gigabit-Ethernet.
PE insulation
StarQuad ViMF Cables are intended for multimedia applica-
Copper tions (voice, image and data communications) where cable
conductor
sharing is an option. Alongside traditional applications
AWG 23
(ISDN, Ethernet and Token Ring), the cables are suitable for
PP foil high frequency transmission, such as TPDDI via copper
(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to
1000 Base-T.
Features
Introduction
Largest resistance margin 2%
Conductor insulation Halogen free
Insulation resistance >5000 MV x km
foam-skin material
Impedance Zo at 0.064 MHz 125 V +/- 20%
Outer jacket Halogen free
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
FutureCom F
flame retardant
Surface transfer impedance <10 m V/m at 10 MHz
Area/range of application Dry and
Unbalance to ground >46 dB at 64 kHz
damp rooms
dB/BZL = 1000 m
Temperature range (installation) 0 to +50°C
FutureCom 10TEN
Unbalance to ground >40 dB at 1 MHz
Operating temperature -20 to +60°C
dB/BZL = 100 m
Min. bending radius 2V: >_ 30 mm (flat side)
Greatest possible loop resistance 130 V/km
for one-time bending 3V: >_ 50 mm
Operating capacity 48 pF/m
4V: >_ 52 mm
FutureCom E
Propagation velocity 0.68 x c
7V: >_ 65 mm
at >10 MHz (NVP x c)
Min. bending radius during 2V: >_ 45 mm (flat side)
Propagation delay >_ 10 MHz 4.9 ns/m
installation 3V: >_ 75 mm
Delay skew 0 ns/100 m
4V: >_ 78 mm
FutureCom D
7V: >_ 100 mm
Copper conductor AWG 23
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 200 300
Attenuation in dB/100 m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 1.8 5.2 6.7 7.5 9.4 13.7 17.6 25.1 30.9
– –
Typical values in dB at 100 m (foursome/foursome) 90.0 90.0 90.0 90.0 90.0 90.0 90.0 80.0 80.0
Hardware
PSNEXT in dB at 100 m * 62.3 47.3 44.2 42.8 39.9 35.4 32.3
Typical values in dB at 100m 76.7 61.1 57.8 56.9 52.8 47.5 44.0 38.0 35.3
– –
ELFEXT in dB at 100 m according * 63.8 43.8 39.7 37.8 33.9 27.9 23.8
PSELFEXT in dB at 100m according * 60.8 40.8 36.7 34.8 30.9 24.9 20.8
Typical values in dB at 100m 73.0 62.0 59.0 57.0 51.0 45.0 41.0 30.0 20.0
– –
ACR in dB 78.2 58.8 54.3 52.5 46.6 36.8 29.4 15.9 7.4
*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)
Ordering Information
Industrial
Cable
Max
Fire Load Zero Tensile Outer [ Weight Length
Type designation Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number
Special
Cable
Application
Foil shielding
Schirmfolie
The FutureCom™ StarQuad ViMF cable is designed for
PVC jacket
Mantel PVC applications in industrial and other harsh environments up
to 300 MHz and its transmission characteristics satisfy
Foil shielding
Schirmfolie Category 5 specifications according to ISO/IEC 11801 (2002)
and EN 50173-1 (2003).
Additional wire
Beidraht
FutureCom ViMF cables are zero-skew products, i.e. the skew
41 Adern
twisted quad
zum Vierer ver-
seilt between the individual pairs of foursomes is very low. This is
PE insulation increasingly required for Gigabit-Ethernet.
PE-Isolierung
Copper conductor StarQuad ViMF cables are intended for multimedia applica-
AWG 23
Kupferleiter AWG 23
tions (voice, image and data communications) where cable
PP foil sharing is an option. Alongside traditional applications
(ISDN, Ethernet and Token Ring), the cables are suitable for
high frequency transmissions, such as TPDDI via copper
(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to
1000 Base-T.
Features
Introduction
Largest resistance margin 2%
Conductor insulation Halogen free
Insulation resistance > 5000 MV x km
foam-skin material
Impedance Zo at 0.064 MHz 125 V +/- 20%
Outer jacket Halogen free
Impedance Zo at 1 - 100 MHz 100 V +/- 15%
flame retardant
FutureCom F
Surface transfer impedance <10 m V/m at 10 MHz
Area/range of application Dry and
Unbalance to ground >46 dB at 64 kHz
damp rooms
dB/BZL = 1000 m
Temperature range (installation) 0 to +50°C
FutureCom 10TEN
Unbalance to ground >40 dB at 1 MHz
Operating temperature -20 to +60°C
dB/BZL = 100 m
Min. bending radius 1V: >_ 30 mm
Greatest possible loop resistance 130 V/km
for one-time bending 2V: >_ 30 mm (flat side)
Operating capacity 48 pF/m
3V: >_ 50 mm
FutureCom E
Propagation velocity 0.68 x c
4V: >_ 52 mm
at >10 MHz (NVP x c)
Min. bending radius during 1V: >_ 45 mm
Propagation delay >_ 10 MHz 4.9 ns/m
installation 2V: >_ 45 mm (flat side)
Delay skew 0 ns/100 m
3V: >_ 75 mm
FutureCom D
4V: >_ 78 mm
Copper conductor AWG 23
FutureCom UD FutureCom UE
Frequency in MHz 1 10 16 20 31.25 62.5 100 200 300
Attenuation in dB/100 m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3
Typical values dB/100m 1.8 5.2 6.7 7.5 9.4 13.7 17.6 25.1 30.9
– –
Typical values in dB at 100 m (foursome/foursome) 90.0 90.0 90.0 90.0 90.0 90.0 90.0 80.0 80.0
Hardware
PSNEXT in dB at 100 m * 62.3 47.3 44.2 42.8 39.9 35.4 32.3
Typical values in dB at 100m 76.7 61.1 57.8 56.9 52.8 47.5 44.0 38.0 35.3
– –
ACR in dB 78.2 58.8 54.3 52.5 46.6 36.8 29.4 15.9 7.4
*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)
Ordering Information
Industrial
Cable
Max Std.
Fire Load Zero Tensile Outer [ Weight Length
Type designation Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number
Special
Cable
13.3. Glossary
On the Internet: Our Training Centers are located in Berlin and Neustadt /
http://www.corning.com/cablesystems Coburg, Germany. Standard and customized courses to meet
Or via E-Mail: individual requirements are held locally throughout the
emea.cs@corning.com world, where the technical facilities permit.
Or by phone under:
Freephone: 00800 2676 4641
Introduction
We guarantee that each customized Corning Cable Systems
LANscape® Cabling Solution meets or exceeds the global
data communication and performance standards. You can
FutureCom F
be assured that your Corning Cable Systems Solution meas-
ures up to the international cabling requirements,
ISO/IEC 11801 and EN 50173 (Europe).
FutureCom 10TEN
Installation Expertise and Reliability LANscape® Solutions Total Package
Corning Cable Systems’ network of LANscape® Extended The LANscape® end to end product offering is designed to
FutureCom E
Warranty Program™ (EWP) installers are carefully selected deliver the most technologically advanced communications
and trained. systems to the customer. Corning Cable Systems LANscape®
products withstand rigorous field and laboratory testing
FutureCom D
Each partner-company meets our stringent requirements for with continual design enhancements in response to rapidly
technical experience, financial strength and proven dedica- evolving customer environments.
tion to quality. EWP partners must demonstrate ongoing
commitment to extensive training and are required to Ready for Your Growing Network
FutureCom UD FutureCom UE
update training at least once every two years.
Corning Cable Systems understands the critical need for
flexible solutions with the rapid growth of your data
communications requirements. With Corning Cable Systems’
LANscape® Solutions, changes and expansions are cost-
effective and simple. Your cost-of-ownership is minimized!
Hardware
Corning Cable Systems’ experts support and assist Extended
Warranty Program installers with the planning, designing,
*The Extended Warranty of Corning Cable Systems is subject to the terms and conditions set forth in the EWP Contract to be signed by each EWP Partner and set
forth in the Warranty Statement granted to the endcustomer of an installation. The liability of Corning Cable Systems for failures /malfunction or alterations of
the specifications published at the date of installation is repair or replacement of the defective product. Corning Cable Systems shall not be liable for any conse-
quential damages or violation of the contract terms with respect to the warranty obligation for this product. The maximum liability of Corning Cable Systems
within the scope of the Extended Warranty Program is repair and replacement of the Corning Cable Systems product that does not comply with the Corning Ca-
ble Systems specifications published at the date of installation of such product plus labor costs in connection with the replacement or the repair of such products
amounting to a maximum of Euro 10.000 (ten thousand).
Introduction
cable.
Attenuation Reduction in electrical signal power between two defined points on a transmission path. It is
frequency dependent and caused mainly by resistance and the skin effect (unit: dB)
Attenuation constant Known also as attenuation coefficient, it is the length related attenuation introduced by the
FutureCom F
cable in the stationary condition (unit: dB/km or dB/100m).
ATM Asynchronous Transfer Mode is a network technology based on transferring data in cells or
packets of fixed size. ATM supports data transfer rates of from 25 to 622 Mbps (megabits per
FutureCom 10TEN
second).
AWG American designation for conductor diameter (American Wire Gauge)
Cable core The totality of cabling elements in the cable and the wrapping covering all these elements.
Cable sheath Covering, generally of polyethylene (PE), polyvinylchloride (PVC) or zero-halogen material (H),
FutureCom E
to protect the cable core against environmental influences.
Capacitance unbalance The difference between the ground capacitances of the two conductors.
Characteristic impedance Complex quantity defining the ratio of voltages to currents in a propagating wave at every
FutureCom D
point along the line.
Conductor The conductor is used for transporting the electrical charge carriers and is therefore made of
electrically conducting material (metal). The conductor is usually round.
Conductor resistance Conductor resistance is determined by the quality of the copper used and the cross-section of
FutureCom UD FutureCom UE
the conductor. It increases linearly with cable length and has a determining influence on the
attenuation.
Corrosive Release of corrosive gases and acids by the combustion of cables and lines. For indoor installa-
tions, non-corrosive cables should be used. Halogen-free cables are generally non corrosive.
DC loop resistance Overall DC resistance of the go and return conductors (unit: ?/km)
Delay skew The difference in time between the arrival (reception) of a data signal and subsequent related
data signals. Usually expressed in nanoseconds.
Dielectric Insulating material, also termed dielectric medium, i.e. an electrically non-conducting material
Hardware
ELFEXT A measurement of the unwanted signal coupling from a transmitter at the near end into an-
other pair, measured at the far end with the effects of the attenuation removed.
FEXT Far-end crosstalk loss is the attenuation between the transmission circuits of a cable at the
reactance, the latter being the frequency-dependent opposition to current flow offered by
inductances and capacitances. Impedance is physically determined by the dimensions of inner
conductor, dielectric and shield.
Insulation resistance This is determined by the insulating material and more particularly by the nature of the
Special
Cable
LAN: Local Area Network Local network for bit-serial transmission between interconnected, independent terminal
equipments. The term LAN was introduced in order to distinguish this network from processor
links (central processor unit with peripherals) operating at very high bit rates over short
distances on the one hand and from publicly accessible networks operating over long
distances on the other.
Length of lay The distance along the center axis of a cable that a cabling element advances in order to
complete one full turn (360°) about this axis.
LS0H/LSZH Low smoke (LS) and zero halogen (0H)
Mutual capacitance Effective capacitance of the line
NEXT Near-end crosstalk loss is the attenuation between the transmission circuits of a cable at the
same end of the cable.
Propagation delay The time required for a signal to pass along a transmission line.
Propagation velocity The velocity of wave propagation along a transmission line.
PS-ACR The difference between attenuation and PSNEXT. The result is referred to as “head room”. The
more head room a cable or system has the more forgiving it will be with the installation errors
(apart from mis-wiring).
PSANEXT Sum of the unwanted signal coupling of crosstalk noise at the near end from external cabling
pairs into an affected pair of cable.
PSELFEXT A computed sum value of the individual ELFEXT effects on each pair by the other 3 pairs.
ELFEXT removes the impact of insertion loss on Far End Crosstalk.
PSNEXT The sum of all pair combinations for crosstalk as it occurs when a signal is introduced into a
communications cable, and measured at the near end to the transmitter
Quad A series of four separately insulated conductors, generally twisted together.
Resistance unbalance Difference in DC resistance between two wires of a circuit (unit: ?)
Return loss The difference between the power incident upon a discontinuity in a transmission system and
the power reflected from the discontinuity.
Shield Structural cable element for shielding. The design of the shield depends on whether one is
seeking protection against electric fields (capacitive coupling) or magnetic fields (inductive
coupling) or against both. Shielding materials against magnetic fields should always have a
high electrical conductivity and small inductance, which is why, in the case of conductors,
copper is mostly used.
Shielding Protects against electric and magnetic influence caused by emission (emitted interference)
and emission (received interference).
Skew A measure of the inequality of propagation delay between two pairs in a multi-pair cable
Skin effect Tendency for higher frequency currents to travel near the outside surface of a conductor
Smoke density Measure of the smoke generated by a burning cable. For indoor installation, cables should be
selected with a low smoke density (typical value: 50%).
Transfer impedance Surface transfer impedance is a measure of the effectiveness of the shielding and is defined as
the ratio of the voltage along the shield of the disturbed system to the current in the
disturbing system.
Twisted pair A transmission line in which two insulated conductors are twisted together.