DX Series
Features of DX series
Simple Operation & Authorization Setup Function Per Each Access Code Because of easy and intuitional menu constitution settable by users, DX series is convenient for operation setup and communicability, and it embeds authorization setup function per each access code, so that it can prevent the equipments from malfunction. Also, it can provide users with very reasonable price in contradistinction with cost in spite of a combination of network ability and control function. Big Size Graphic LCD (240x128, 5 inch) DX series applies for big size graphic LCD which makes it possible to provide users with several languages (Korean, Chinese, English and Japanese). Also, it maximizes usersconvenience by supporting both graphic and text interface. (Wide temperature range type : -20~70) Error Message & Alarm Display (Operation Status Recording Devise Embedded) DX series can display error information such as failure or malfunction of the equipments with a simple message, so users or engineers can check and manage the equipments. Also, it can save maximum 200 shut down histories and states when error occurred, so it provides users with easy analysis of problems. (Embedding black box function) Reliable Preventative and Maintenance Function DX series provides users with the information about a cycle of PM and consumable parts exchanging schedule which is very helpful not only to maintain good state of the equipment but also to save PM cost. Solution against Noise from the External Environment It is a mandatory requirement to have a solution against noise as an industrial controller. DX series has insulated digital input and output signal which prevents the external signal from going into inside of main board. And, Watch Dog timer is operating in CPU per every 32msec which automatically recovers from CPU down occurred by noise. Also, brownout function is embedded in CPU inside for a real-time detection of control power. Various Analogue Output Function DX series can basically use 3 of 4~20mA output. 3 of analogue output can be applied for the required controlling or transmitting output according to users setting. RS485 Communication Function Applying for RS485 communication method based on MODBUS RTU/ASCII Protocol, DX series helps users to construct convenient SCADA/HMI system which is possible for precise central concentrated monitoring with PLC, PC, and touch screen. Compact & Slim Size Because of unified type of main control part and display part, the size of compressor can be minimized by securing enough places. Various Sensor Lineups DX series can be used with various lineups of DOTECHs sensors for temperature, humidity, pressure and differential pressure, so it provides users with excellent compatibility and extended application. IP65 Certification DX series has passed IP65 front side test, so it is possible to be used in poor environment, such as dusty and humid place.
02
Composition of DX series
Product category for various applications DX series is composed of various applications like HVAC, screw, scroll, multi, ground/water source heat pump and air compressor, user can use various functions of DX series if user buy it depending on their purpose.
DX series
HVAC
Screw
Recipro Scroll
Multi
Heat Pump
DX100/120/140 Series
DX200/220/240/270 Series
DX230 Series
DX260 Series
DX230H/DX540H Series
03
HVAC Controller
DX100 series based on microprocessor has realized the best control and stability with efficient control for HVAC units (AHU, constant temperature & humidity unit and dehumidifier) and perfect interface with safety devices. Its elegant graphic LCD display and LED helps users to check the current state of the units. - Temperature & humidity control function, Max. 6 loop of independent step operating function - Alternative operation by max. 4 compressors and 8 heaters - Backup operating function - Prevention from frequent starting failure occurred by low pressure hunting using low pressure switch in compressor - Successive starting function, pump down function and prevention from restarting function - Control function for cold water, hot water, steam valve, SCR, damper designed for HVAC (4~20mA PID control) - Detection of error in temperature and humidity sensor, Alarm function, Output of equipment state (Cooling and Dehumidification, Heating and Humidification)
- DX140 : Exclusive controller for constant temp. and humidity unit Models DX100 DX120
OK OK OK (PID control) OK (PID control) OK (PID control) OK (PID control) OK (PID control) OK OK OK OK OK OK OK
DX140
10 12 1 1 2 5 2 1 -
Main Specification
Trip / Alarm Recording Function Schedule Run/Stop Function Cool / Dehumidify Analog Control Cooling Analog Control Heating Analog Control Humidify Analog Control Diff. Pressure Analog Control Temperature Retransmission Output Humidify Retransmission Output Diff. Press. Retransmission Output React Heater SCR on/off Control Heater SCR on/off Control Humidify Heater SCR on/off Control Cooling State on/off Control
DX140
OK(P control) OK(P control) OK(P control) OK(P control) OK(P control) -
HEAT CONTROL DIFFERENCE Input standard been driving/suspension control sensitivity of Heating control.
Current Temp. Set Temp. Heat control Diff. Heat control Diff. x2 Heater #1
ON ON
ON ON
Heater #2
HUMIDITY CONTROL DIFFERENCE When drive humidification, input control sensitivity that get into standard of step driving of humidifier.
Current Humidity Set Humidity Humidity diff. Humidity diff. x2
Humidifier #1
ON ON
04
Humidifier #2
When control react heater in dry type of dehumidifier, if [CONTROL SET: REACT HETER CONTROL] is OFF, it controls react heater's step according to current humidity.
When control react heater in dry dehumidifier, control step of react heater according to present react heater temperature if [CONTROL SET: REACT HEATER CONTROL] is ON. .(Figure, When 2 Step Control)
Applications
Exhaust Air Outside Air
Supply Air
Return Air
- Constant temperature & humidity unit - AHU - Dry type dehumidifier - Various types HVAC system
Screen Composition
Temperature + Humidity Control Display
PV
MENU Composition
OPERATION
Current Temperature Set Temperature Digital Output State Operation State Digital Input State
SP
25.0
25.0
PV
50.0
50.0
SET TEMPERATURE
Current Humidity
SP
MENU SELECT
Set Humidity Current Time Alarm Message Equipment State Code
08:20
08
LOC STP
C1A LP1 LP2 C2A
DPS. ALARM
RHA AFS HUA BRA RET
TRIP LOG
00 01 02 03 04 080102 080102 080102 080102 080102 15:55 16:10 16:30 16:30 16:45 X FIRST POWER ON FAN FAULT COMP#1 FAULT COMP#2 FAULT HEATER FAULT
Lock Signal
Current Temperature
25.0
C SP
25.0
ALR BRO
Set Temp.
Current Humidity
50.0
SP
50.0
STAND BY
08:20
08
08:20
08
LOC STP
C1A LP1 LP2 C2A RHA AFS
STAND BY
BRA RET
LOC STP
C1A LP1 LP2 C2A
AC 220V, 50/60Hz after Noise filter Output Terminal 100 200 LEGEND LEGEND COMPRESSOR #1 ON/OFF CONTROL MAIN SOL #1 ON/OFF CONTROL COMPRESSOR #2 ON/OFF CONTROL MAIN SOL #2 ON/OFF CONTROL DESC. N1 N2 N3 N4 TERMINAL NO J21 - 1 J21 - 2 J21 - 3 J21 - 4 J21 - 5 COMP 2 SOL 2 COMP 1 SOL 1 FUSE 3A
OUTPUT COMMON 1 C1 RE-HEATER #1 ON/OFF CONTROL RE-HEATER #2 ON/OFF CONTROL MULTI-FUNCTION ON/OFF CONTROL MULTI-FUNCTION ON/OFF CONTROL
N5 N6 N3 N8
RH1 RH2 N7 N8
Compressor #1 Alarm LP Switch for Comp #1 Compressor #2 Alarm LP Switch for Comp #2 Halon, Smog Detector React Fan OCR
OUTPUT COMMON 2 C2 MULTI-FUNCTION ON/OFF CONTROL MULTI-FUNCTION ON/OFF CONTROL MULTI-FUNCTION ON/OFF CONTROL BROWER (Pump) ON/OFF CONTROL
ID COMMON
Re-Heater Alarm Flow SW Humidifier Alarm Brower(Pump) Over Current Remote Signal G (HOT)
OUTPUT COMMON 3 C3 J14 - 1 J14 - 2 J14 - 3 J14 - 4 J14 - 5 J14 - 6 ID6 ID7 ID8 ID9 ID10 IDCM2 RE-HEATER OT Flow S/W HUMIDIFY ALARM BROWER OCR REMOTE ON/OFF ID COMMON
* Optional Spec. J6 - 1 MULTI-FUNCTION Y1 ANALOG#1(4~20mA) YG1 J6 - 2 MULTI-FUNCTION Y2 J6 - 3 ANALOG#2(4~20mA) YG2 J6 - 4 J6 - 5 MULTI-FUNCTION Y3 ANALOG#3(4~20mA) YG3 J6 - 6 * MULTI-FUNCTION CONTROL (Selctable user) PID ANALOG #1~3 DIGITAL ON/OFF(N7~N11) 1. Cool & Dehumid 2.Cool Control 3. Dehumid. Control 4. Heat Control 5. Diff. Press Control 7. Temperature Retrans. 8. Humidity Retrans. 9. Diff. Retrans. 1. Heater #3~#7 2. Humidifier #1~#4 3. Total alarm 4. Error (Over/Under Range) 5. React Fan 6. React Heater #1~#4 7. Run/Stop State 8. Cool State 9. Heat State 10. Dehumidify State 11. Humidify State
EXTENTION BOARD
* Optional Spec. TB1 - 1 SG TB1 - 2 B TB1 - 3 A * Optional Spec. TB2 - 1 SG TB2 - 2 B TB2 - 3 A
05
Applications
- Water cooled & air cooled screw compressor - Chiller, CDU, Spot-Cooler - HeatPump System
Screen Composition
DX200 (Stepless)
PV
MENU Composition
C SP
Current Temperature
25.5
7.0
STAND BY
OPERATION
Set Temperature Discharge Gas Temperature Current Time Alarm Message Equipment State Code
Set Point
D.C GAS :
ALR PM
14 C 08 : 20 51
MENU SELECT
RUN INFO OPERATION TRIP LOG TRIP & ALARM
1 Step Start Deviation 2 Step Start Deviation 1 Step Stop Deviation 2 Step Stop Deviation
: : : : :
LOC STP
OCC REV LPS HPS
TRIP LOG
23 24 25 26 7 000101 000101 000101 000101 000101 00:00 Low Temp Alarm 00:00 Outlet T-Sense Fault 00:00 DC Gas#1 T sensor 00:00 DC Gas#2 T sensor 00:00 X Low Temp Alarm
Lock Signal
DX270 (Step)
PV
Current Temperature
25.5
C SP
7.0
Set Temperature Discharge Gas Temperature Current Time Alarm Message Equipment State Code
D.C GAS :
ALR PM
14 C 08 : 20 51
LOC STP
OCC REV LPS HPS OLS OVH
GOOD
FS PIL RET
START READY
Lock Signal
MC for Main / PW1 MC for Star(Y) / PW2 MC for Delta(D) SOL for Liquid Injection
N5 N6 N3 N8
R5 R6 R7 R8
Over-Temp Main Motor Overload Condensor-Fan Motor Interlock Pump(Fan), Flow Switch Overload Pump(Fan) Motor Alarm Remote Run/Stop
Analog Option (Only DX200-X1 Model) Y1 Inlet Temp retrans. YG1 Y2 Outlet Temp retrans. YG2 DC Gas Temp retrans. Y3 YG3
06
DX220
Applications
- Water cooled & air cooled screw compressor - Chiller, CDU, Spot-Cooler - HeatPump System
Screen Composition
MENU Composition
OPERATION
SET VALUE
: 7.0 RUN DIFFERENTIAL : +1.0 : -0.5 STOP DIFFERENTIAL 50% CAP. DIFFERENTIAL : +0.2 75% CAP. DIFFERENTIAL : -0.2
Current Temperature
PV
25.5
C SP :
IN : GAS#1 : GAS#1 :
ALR
10.0 C 0.8 C 25 C 45 C
Set Temperature
MENU SELECT
RUN INFO OPERATION TRIP LOG TRIP & ALARM
08 : 20
STAND BY
LOC STP
51
Lock Signal
TRIP LOG
05 000101 06 000101 07 000101 08 000101 09 000101 00:00 COND-FAN FAULT 00:00 COMP INT FAULT 00:00 OUTLET SENS. FLT 00:00 DS GAS SENS. FLT 00:00 INLET SENS FLT
07
DX230
Applications
- Water cooled & air cooled compressor - Chiller, CDU, Spot-Cooler - HeatPump System
Screen Composition
MENU Composition
OPERATION
SET VALUE
RUN DIFFERENTIAL CAP DIFFERENTIAL #1 CAP DIFFERENTIAL #2 CAP DIFFERENTIAL #3 : 7.0 : + 3.0 : + 0.5 : + 1.0 : + 1.5
MENU SELECT
Current Temperature
PV
7.5
C SP
7.0
STAND BY
Set Temperature Discharge Gas Temperature Current Time Alarm Message Equipment State Code
TRIP LOG
00 01 02 03 04 080102 080102 080102 080102 080102 15:55 POWER ON FIRST 16:10 PUMP(FAN) FAULT 16:30 COMP OCR 16:30 PHASE FAULT 16:45 X HIPRESS FAULT
D.C GAS :
ALR PM
13 C 08 : 20 02
Lock Signal
LOC STP
OCC REV HPS OPS OCF FS PIL RET
MC for Main / PW1 MC for Star(Y) / PW2 MC for Delta(D) SOL V/V FOR LIQUID OUTPUT COMMON 2
N5 N6 N3 N8 C2
R5 R6 R7 R8
Over-Temp Main Motor Overload Condensor-Fan Motor Interlock Pump(Fan), Flow Switch Overload Pump(Fan) Motor Alarm Remote Run/Stop
Analog Optoin(Only DX230-x1 Model) Y1 Overload Condenser Fan Inlet Temp retrans. YG1 Flow Switch Interlock Pump Remote On/Off Signal ID COMMON 2 Outlet Temp retrans. DC Gas Temp retrans. Y2 YG2 Y3 YG3
EXTENTION BOARD
08
DX260
Applications
- Multi Condensing Unit - Multi Compressor Control
Screen Composition
MENU Composition
OPERATION
COMP SET VALUE :
COMP STEP DIFF RUN/STOP DIFF FAN SET VALUE FAN STOP DIFF : : : : 1.8 bar +0.40 bar +1.00 bar 13.0 bar + 0.7 bar
MENU SELECT
PV
2.0
bar
SP
2.0
12.3
STAND BY
bar
Set Low Pressure High Pressure Currrent Time Alarm Message Equipment State Code
HPrs
bar
TRIP LOG
00 01 02 03 04 080102 080102 080102 080102 080102 15:55 16:10 16:30 16:30 16:45 POWER ON FIRST COMP#1 FAULT COMP#2 FAULT COMP#3 FAULT X COMP#4 FAULT
08:20
06
Lock Signal
LOC STP
CA1 CA2 CA3 CA4 FA1 FA2 FA3 FA4 ILC RET
AC 24V, 50/60Hz G LEGEND LEGEND COMPRESSOR #1 ON/OFF CONTROL 24VAC 50/60Hz CONTROLLER POWER INPUT COMPRESSOR #2 ON/OFF CONTROL COMPRESSOR #3 ON/OFF CONTROL COMPRESSOR #4 ON/OFF CONTROL OUTPUTCOMMON 1 CONDENSER #1 ON/OFF CONTROL CONDENSER #2 ON/OFF CONTROL CONDENSER #3 ON/OFF CONTROL CONDENSER #4 ON/OFF CONTROL OUTPUT COMMON 2 DESC. N1 N2 N3 N4 C1 TERMINAL NO J21 - 1 J21 - 2 J21 - 3 J21 - 4 J21 - 5 R3 R4 R1 R2 FUSE 3A G0
DESC. FG G0 G +24V B4 B5 GND B1 GND B2 GND B3 ID1 ID2 ID3 ID4 ID5 IDC1
HIGH PRESSURE
0.0 ~ 30.0 bar
LOW PRESSURE (4~20mA) HIGH PRESSURE (4~20mA) TEMP INPUT -40 ~ 70 SPARE TEMP SPARE TEMP
N5 N6 N7 N8 C2
R5 R6 R7 R8
Compressor #1 Alarm Compressor #2 Alarm Compressor #3 Alarm Compressor #4 Alarm Condenser #1 Alarm G (HOT)
COMP#1 ALARM COMP#2 ALARM COMP#3 ALARM COMP#4 ALARM FAN#1 ALARM ID COMMON
TOTAL ALARM STATE SIGNAL COMP RUN/STOP STATE SIGNAL COMP ALL ALARM STATE SIGNAL SYSTEM RUN/STOP STATE SIGNAL OUTPUT COMMON 3
Condenser #2 Alarm Condenser #3 Alarm Condenser #4 Alarm Interlock Alarm Remote Signal G (HOT)
FAN#2 ALARM FAN#3 ALARM FAN#4 ALARM INTERLOCK ALARM REMOTE ON/OFF ID COMMON
* Optional Spec. MULTI FUNCTION ANALOG#1(4~20mA) MULTI FUNCTION ANALOG#2(4~20mA) MULTI FUNCTION ANALOG#3(4~20mA)
* MULTI - FUNCTION CONTROL (Selctable User) MULTI FUNCTION (N9~N12) * OFF * RUN STATE * RUN WAIT STATE * COMP RUN * FAN RUN * TOTAL ALARM * COMP ALARM * FAN ALARM * COMP ALL ALARM * FAN ALL ALARM
* Optional Spec. SG TB1 - 1 B TB1 - 2 A TB1 - 3 * Optional Spec. TB2 - 1 SG TB2 - 2 B TB2 - 3 A
09
DX230H
Applications
- Geothermy & Water-cooled Heat Pump - Air-cooled Heat Pump - Waste Heat Recovery Pump
Screen Composition
MENU Composition
OPERATION
COOL SET VALUE
: 7.0 COOL SET VALUE NIGHT : 7.0 COOL RUN DIFFERENTIAL : +1.0 HEAT SET VALUE : 30.0 HEAT RUN DIFFERENTIAL : -1.0
PV
Current Temperature
7.5
LIS
C SP
MENU SELECT
45
24.8
STAND BY
Set Temperature Geothermy Output Temperature Current Time Alarm Message Equipment State Code
GEO TEMP. :
ALR 4W PM
TRIP LOG
00 01 02 03 04 080102 080102 080102 080102 080102 15:55 16:10 16:30 16:30 16:45 POWER ON FIRST POWER ON COMP OCR POWER OFF X COMP OCR
SOL CM CY CD
08 : 20 02
GOOD
Run/Stop State
Heating, Day/Night Equipment State Lock Signal Cooling operation State (Failure, Alarm, Maintain) State
MAIN SOL #1 N1 ON/OFF CONTROL COMP #1 MAIN/PW1 N2 ON/OFF CONTROL COMP #1 STAR/PW2 N3 ON/OFF CONTROL COMP #1 DELTA ON/OFF CONTROL N4
OUTPUT COMMON 1 C1
N6 L.INJECTIN SOL ON/OFF SIGNAL N3 N8 OUTPUT COMMON 2 C2 NIGHT MODE ON/OFF SIGNAL COMPRESSOR ALARM SIGNAL 4 WAY SOL ON/OFF CONTROL BROWER (Pump) ON/OFF CONTROL
DC GAS TEMP OVERLOAD MAIN MOTOR OIL PRESS ALARM INT. THERMO ALARM LOW PRESS SWITCH HIGH PRESS SWITCH ID COMMON 1
Spare COOL / HEAT-ON SWITCH FLOW SWITCH PUMP(FAN) ALARM REMOTE ON/OFF ID COMMON 2
* Optional Spec. Inlet Temp reTrans. Y1 ANALOG#1(4~20mA) YG1 Outlet Temp reTrans. Y2 ANALOG#2(4~20mA) YG2 Geo-Outlet Temp Y3 ANALOG#2(4~20mA) YG3
+ + + -
10
EXTENTION BOARD
* Optional Spec. TB1 - 1 SG TB1 - 2 B TB1 - 3 A * Optional Spec. TB2 - 1 SG TB2 - 2 B TB2 - 3 A
DX540H
Applications
Screen Composition
MENU Composition
OPERATION
HEAT SET VALUE
HEAT SET VALUE STEP1 OP DEV. STEP2 OP DEV. STEP2 STOP DEV. : 7.0 : -50.0 : -2.0 : -3.0 : 0.0
24.5
C1 C2 SOL
LOC STP
MENU SELECT
RUN INFO OPERATION SCHEDULE TRIP LOG
TRIP LOG
00 01 02 03 04 080102 080102 080102 080102 080102 15:55 16:10 16:30 16:30 16:45 INLET FAULT OUTLET FAULT OUT AIR FAULT DISCHARGE FAULT X EVAPO. FAULT
DEF
08 : 20 02
Lock Signal
Discharge Fault
Heating/Cooling State
11
Basic Specification
Power spec.
Input Power Consumption CPU AC24V 50/60Hz, DC24V Max. 20VA ATmega 128, 16MHz 240 X 128 Pixel, LED Backlight Opto-Isolation 10 (5X2 Common) AC24V or DC24V Relay contact 12 (4X3 Common) 250V, 10A Indoor -10~60 Type RS485 (Half-Duplex Type) 1 channel (MODBUS RTU) 4800, 9600, 19200, 38400 BPS(default 9600) Parity None, Data 8bit, Stop 1bit Max. 1.2 km BELDEN 9842 or 8761 NTC x 3 (Max. 5) 2 (Build-in power 24V for sensor)
Communication
Speed Distance
CPU/LCD
LCD Type
Cable
Digital Input
Difference Correction Software Channel No. Type Setup Type Storing Temp. Operating Humidity 3 Channel 4~20mA Software -30~80 5~95 in No condensation state
Dimensions
230
45 204
192x130
Mount Hole : 5pie X 4 EA (mm)
90
150
HTX23
OEM Temp. & Humidity Sensor
HTX32C
Indoor Temp. & Humidity Transmitter
HTX62C/D
Industrial Temp., Humidity & Dew Point Temp. Transmitter
HTX72/73C
Climate Control Temp., & Humidity Transmitter
HTD500
Ultra-precise Indoor Type Temp.& Humidit Transmitter
Temperature Sensor
DPR-TH2-P6D-100L
Sensor type : NTC 10K Range : -40 ~ 150 Accuracy : 1.5 at 25 Sheath : 6 X 100mm, SUS Protection : IP67 Cable : 2C X 0.5mm, sus-mesh shield tefron
Pressure Sensor
DP510
Measuring range : 0 ~ 16bar, 4~20mA Accuracy : Within 1%FS Size : Small type Temperature Range : -40 ~ 125 Applications : Automobiles & Heavy Equipments, Oil & Air Pressure Systems, Compressors, Industrial Engines, Pump Pressure Controls
DPR-TH1-S6D100L
Sensor type : NTC 5K Range : -50 ~ 105 Accuracy : 0.3 at 25 Sheath : 6 X 100mm, SUS Protection : IP67 Cable : 2C X 0.5mm, sus-mesh shield tefron
506.933A/506.930A
DOTECH OEM Model : 506.933A For High Pressure (0~30bar) DOTECH OEM Model : 506.930A For Low Pressure (-1~9bar) - Measuring pressure in pipe (water, oil, gas) - Applying for all the refrigerants including ammonia (for freezing) - EMC conformity - Accuracy : 0.5% FS - Using Temperature : -40 ~ 125 - Insulation Class : IP67 - Output : 0~5V, 8~33VDC, 3wire 0~10V, 11.4~33VDC 16~34VDC/24VAC 4~20mA, 8~33VDC, 2wire
DPR-TH1-H6D100L
Sensor type : NTC 5K Range : -50 ~ 105 Accuracy : 0.3 at 25 Sheath : 6 X 100mm, SUS Protection : IP67 Cable : 2C X 0.5mm
www.dotech21.com business@dotech21.com
6F, JOONGANG-ILBO 778 Wonsi-Dong, Danwon-Gu, Ansan-City, Gyeonggi-Do, Korea TEL : +82-31-495-3767 FAX : +82-31-495-3917