SIT Group

SIT 390 MIXER

INTEGRATED SYSTEM PERFORMING THE GAS/AIR FLOW CONTROL AND MIXING


Application
Subject to change without notice

Main features Two heat-input models. Wide modulation range.

Fan assisted gas fired appliances with premix burner. 390 MIXER is particularly suitable for modulating condensing boilers.

9.955.048 048

GENERAL DATA
CONSTRUCTION CHARACTERISTICS
Die casting aluminium body Air signal to the gas/air control connection

USE SPECIFICATION
Mounting Position Gas families Ambient temperature Downstream of the fan 2nd and 3rd No inconvenience in operation within standard working condition of gas appliances (-20....+100 C)

MECHANICAL CONNECTIONS
Air inlet and mixture outlet Gas inlet M5 (4) Flanges G 3/4 ISO 228 or: Rp 1/2 ISO 7 or: M4 (4) Flanges 6.5 mm

Air signal

DESCRIPTION
1 Gas/Air mixture outlet. Air Inlet. Gas Inlet.

2 3 4

2
Air signal connection.

CAPACITY
MAXIMUM HEAT INPUT
Maximum heat input available with reference to the pressure drop between the outlet and the inlet of the 390 MIXER in operating condition. Reference conditions: gas G20.

Maximum Heat Input (indicative)


Heat Input based on gross CV kW 60
50 40 30 20 10 0 0 50 100 150 200 250 300 350 400 450 500 550 600 650

Heat Input based on nett CV


54

kW

#2

45 36

#1

27 18 9 0 700

p [Pa]

Model MIXER #1 #2 390. 0xx 390. 1xx

Reference Heat Input 25 kW 35 kW

MINIMUM HEAT INPUT


The minimum available heat input is strictly related to the appliance characteristics. As a general guideline the minimum heat input is 20% of the maximum (modulation range 1:5). In the following table the nominal value of the minimum heat input, when the minimum pressure drop between the inlet of 390 MIXER and gas injection section is 50 Pa, is reported. Reference conditions: gas G20, gross calorific value.
Model MIXER 390. 0xx 390. 1xx Minimum Heat 5 kW 7 kW

OPERATION
390 MIXER

gas

848 SIGMA

Stand by - With the appliance in not-operating condition there is no air flow and the gas way is closed by the gas/air control valves.

390 MIXER

air

gas

848 SIGMA

Pre-purge - When the appliance is in pre-purge condition there is air flow through MIXER.

OPERATION
390 MIXER

air

gas

848 SIGMA

Operating - Automatic shut off valves open. The gas flows through the control and it is injected inside the MIXER in the mixing chamber. Then the gas/air mixture leaves the MIXER and goes to the burner.

INNER VIEW
The inner profiles of MIXER are designed and realised in order to ensure the mixing functions and to increase the modulating range.

Gas inlet chamber Venturi Pipe

Gas/Air mixing chamber

Air signal compensation chamber

390 MIXER

LAY-OUT ASSEMBLING

BURNER

MIXTURE

GAS

390 MIXER

848 SIGMA
AIR

FAN

AIR SIGNAL

70

50 6.5

50

60

47

54

70

DIMENSIONS

60

96

Gas Connection: Flanges version

Gas Connection: G 3/4 version


G3/4 ISO 228

32

24

24 32

SIT GROUP www.sitgroup.it - e-mail: mkt@sitgroup.it