Академический Документы
Профессиональный Документы
Культура Документы
Agenda
Introduction
NetBotz Product Review
NetBotz Output Control Automation NetBotz Camera Settings Whats New RackAccess PX-HID
EXTERNAL SENSORS NetBotz sensors Dry Contact sensors 0-5V sensors 4-20mA sensors DEVICE MONITORING Servers Routers, Switches UPS Intelligent PDUs
a company of Schneider Electric
SNM P, I PM I,
SENSOR PODS
500
Camera Pod
500
Sensor Pod
Temp
Temp
Fluid
Business Impact
Loss of Business Continuity
Lost Revenue Lower customer service levels Lost employee productivity Opportunity costs
Loss of Accountability
No audit trails Inability to identify and correct root cause
Insufficient staff
No early warning mechanism
ng bli Ca
w Po er
Racks
and Physical Structure
Coo lin
NCPI
Thresholds Detection
ALERT PROFILE
Thresholds
Analog Value Threshold Types
Minimum / Maximum Above / Below Value for x time Rate of Increase / Decrease Examples: Temperature, Humidity, Airflow, Current, CPU temp inside server
Examples: Fluid, Camera Motion, Vibration, Battery status indicator from UPS
Setting a Threshold
Setting a Threshold
Cameras to Trigger
Specify one or more cameras to be triggered upon threshold events
- Only cameras under control of the same NetBotz appliance (including pod-shared cameras) can be triggered User-specified URL & User-specified Description
Provide information to alert recipient (e.g. alert console operator) on steps to resolve, who to contact, etc.
Return to Normal Requires User Input Alert Profile drop box (if more than 1 profile has been created)
Threshold Schedule
ALERT PROFILE
Send an alert to a web application using HTTP POST or HTTP GET Send alert to an FTP file location Call Web Services Alert Receiver
Enable alerts to be processed by custom application
Specify threshold severity levels to which this alert action will respond
Set up different alert actions for different severity levels
Location Fields
Configure additional location information for pods and sensors Location field values be included in alert notifications sent by the appliance Examples: Position in Rack, Rack ID, Floor Number, Room Number, etc.
HTTP POST
SNMP
Activate Button
Triggers an output relay that has been defined as a Button Relay Can be triggered upon event and upon return-to-normal Predefined one-second and 10-second buttons; can customize buttons with different times
ALERT PROFILE
Alert Profiles
Audio Capture
Record audio as well as video with alert camera captures
Camera Block-Out
Configure cameras so that specified areas of the image cannot be seen (Example: keypad)
Door handles (with integrated proximity reader and lock strike) retrofit into front & rear doors
Dual authentication and audit trail Integrate with Netbotz surveillance for visual and proximity card identification
Sales Tools
Custom Online Demos
Book a Live Online Demo, and we will have one of the NetBotz experts walk your customer through a custom demo (as well as help creating a solution).
Contact Information
For specific product questions contact:
Rick Camp rick.camp@apcc.com Chip Clark chip.clark@apcc.com