Академический Документы
Профессиональный Документы
Культура Документы
Change report
Air Channel
PRIMERGY Server
Instructions
This document contains basic product and configuration information that will enable you to configure your system via PC-/SystemArchitect.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Rack system.
You can configure your individual PRIMERGY server in order to adjust your specific requirements.
The System configurator is divided into several chapters that are identical to the current price list and PC-/SystemArchitect.
Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through the configurator by following the lines from the top to the bottom.
Section
III
Memory
There are X memory slots which can be equipped with XXX MB. It is permissible to make up to X passes through the memory upgrade options.
In one chapter you can only select as many components (here 4x) as the arrow indicates.
4x
Please note that there are information symbols which indicate necessary information.
Prices and availability see price list and PC-/SystemArchitect. Subject to change and errors excepted.
2 of 31
or
Box
optional:
F-D-L1
F-D-LHDD- Box 2
1.6 * 5.25"
1.6 * 5.25"
Local View/CSS/FD Slim DVD
1.6 * 5.25"
Local View / CSS
Slim DVD Hot plug CPU-Fan 0 only with hot plug fans Slim FD
SAS / SATA
SAS / SATA
Air - Channel
Accessible drives ( V )
Hot plug CPU-Fan 1 only with hot plug fans
optional F-D-L-Box 1 occupies one 5.25" bay: - support for optional LocalView, Slim DVD and Slim FD optional F-D-L-HDD-Box 2 occupies two 5.25" bays: - support for up to 2 hot plug SAS/SATA 1"HDDs and optional one Slim CD/DVD and 1x LocalView or Slim FD
Processor ( II )
Xeon Dual-or Quad Core CPU with 1066 or 1333 MHz Frontsidebus
Hard disk drives ( VI ) Silent Fanbridge Fan 2 3.5" SAS / SATA hot plug Fan 2 ( Hot plug fans for hot plug power supply ) hot plug Fan 4
1x 6-port SAS backplane
Extension slots for: SCSI Controller for backup( VII ) SAS Disk Array ( VIII ) Communication/Network ( IX ) Miscellaneous ( X )
Slot 3 wired x8
internal USB
Key:
Option
One CPU ( first CPU ) and one memory ( first memory ) has to be selected for an orderable basic unit.
3 of 31
or
Box
optional:
F-D-L1
2.5" SAS
HDD- Extension
1.6 * 5.25"
2.5" SAS 2.5" SAS 2.5" SAS 2.5" SAS 2.5" SAS 2.5" SAS 2.5" SAS 2.5" SAS
8x 2.5" SAS
1.6 * 5.25"
Local View / CSS
Slim DVD Hot plug CPU-Fan 0 only with hot plug fans Slim FD
Air - Channel
Accessible drives ( V )
Hot plug CPU-Fan 1 only with hot plug fans
optional F-D-L-Box 1 occupies one 5.25" bay: - support for optional CSS or LocalView modul, Slim DVD and Slim FD optional 2.5" SAS HDD-Extension occupies two 5.25" bays: - support for up to 8 hot plug SAS 2.5" HDDs
Processor ( II )
Xeon Dual-or Quad Core CPU with 1066 or 1333 MHz Frontsidebus
Hard disk drives ( VI ) Silent Fanbridge Fan 2 2.5" SAS hot plug Fan 2 ( Hot plug fans for hot plug power supply ) hot plug Fan 4
1x 12-port SAS backplane
Extension slots for: SCSI Controller for backup( VII ) SAS Disk Array ( VIII ) Communication/Network ( IX ) Miscellaneous ( X )
1 * 2.5" SAS
1 * 2.5" SAS
1 * 2.5" SAS
Slot 3 wired x8
internal USB
Key:
Option
One CPU ( first CPU ) and one memory ( first memory ) has to be selected for an orderable basic unit.
1 * 2.5" SAS
4 of 31
without OEM-Software for PRIMERGY Server OEM-SW is bound to HW and is not allowed to be ordered separately. Exception: VMware SW
For all SW products listed below please refer to the corresponding software configurator accessible via the Extranet under "PC Configurations, Configurator for PRIMERGY SW", URL see below
Microsoft - Software: W **) - Windows Server 2003 R2, Standard Edition Enterprise Edition ! Web Edition, SP2/English
Linux - Software **) - Open Enterprise Server ***) - SuSE Linux ES (OEM): LO - SuSE Linux ES (Support): LS - Red Hat EL (OEM): LO - Red Hat EL (Support): LS
Backup-Software: U - ARCserve ***) Supply over distribution or procurement from FSC VP BC Software
You'll find single software configurators and release lists (OS-matrix / system management / security) under following addresses:
5 of 31
without OEM-Software for PRIMERGY Server OEM-SW is bound to HW and is not allowed to be ordered separately. Exception: VMware SW
For all SW products please refer to the corresponding software configurator accessible via the Extranet under "Configuration & Tools, -All configurations, -Software, URL see below.
only EM64T
Microsoft - Software: W - Windows Server 2003 R2, Standard x64 Edition Enterprise x64 Edition
Linux - Software *) **) only - SuSE Linux ES (OEM): LO x86_64 - SuSE Linux ES (Support): LS - Red Hat EL (OEM): LO - Red Hat EL (Support): LS
only EM64T
MultiPath, Duplex Data Manager (DDM) Linux (W-DDM) Details eg. version numbers are published in the separate SW-Configurator
**) Pay attention to release and order information in PRINCE -> Operating System
You'll find single software configurators and release lists (OS-matrix / system management / security) under following addresses:
6 of 31
7 of 31
A Interfaces at the rear: * 1x RS-232-C (serial, 9 pins) (usable for BMC or OS or shared) * 1x RS-232-C (serial, 9 pins) * 1x optional Centronics (parallel, 25 pin, EPP/ECP compatible) * 1x keyboard (PS/2) * 1x mouse (PS/2) * 1x VGA (15 pins) * 2x USB 2.0 ( UHCI ) with 480MBit/s, no USB wakeup * 2x LAN RJ45, 1x Service-LAN RJ45 Interfaces on the front: * 1x USB 2.0 ( UHCI ) with 480MBit/s, no USB wakeup
Interfaces internal: * 2x released internal USB Interfaces for backup devices, * 1x USB 2.0 ( UHCI ) with 480MBit/s for dongle funcionality, no USB wakeup *Cables: 1.) 1x SATA cable for DVD 2.) 2x SAS cables for connection of 4 SAS-ports each incl. signaling * PS/2 mouse (only for floorstand version) * ServerView Suite Software package incl. ServerStart, ServerBooks, Management Software and Updates * Documentation engl. (multilingual on CD)
8 of 31
Floorstand-version S26361-K1159-V101 without CPU and Memory with: - 1 standard power supply 605W ( non hot plug, no redundancy ) - Two standard fans ( non hot plug, no redundancy ) - 6-port SAS backplane for 6x 3.5" hot plug SAS or SATA HD`s incl. cables for connection to the modular 8-port SAS controllers - One memory board for 4 memory DIMM pairs
Rack-version S26361-K1159-V301 without CPU and Memory with: - 1 standard power supply 605W ( non hot plug, no redundancy ) - Two standard fans ( non hot plug, no redundancy ) - 6-port SAS backplane for 6x 3.5" hot plug SAS or SATA HD`s incl. cables for connection to the modular 8-port SAS controllers - One memory board for 4 memory DIMM pairs - 2 power cords with inlet connector for non-heating apparatus - One CPU ( first CPU ) has to be configured additionally for a base configuration - One memory kit has to be configured for a base configuration - No Rackmount Kit included ! - The Rackmount Kit or the option no Rackmount Kit has to be ordered separate
- One CPU ( first CPU ) has to be configured additionally for a base configuration - One memory kit has to be configured for a base configuration - Mouse with two pushbuttons
Floorstand-version S26361-K1159-V201 without CPU and Memory Floorstand-version S26361-K1159-V222 ESX Server 3i Embedded without CPU and Memory with: - 1 hot-plug power supply 700W ( Redundancy through configuration of 2nd power supply 700W ) - Four hot-plug fans ( Redundancy through configuration of Redundant hot plug Fan Kit ) - 6-port SAS backplane for 6x 3.5" hot plug SAS or SATA HD`s incl. cables for connection to the modular 8-port SAS controllers - One memory board for 4 memory DIMM pairs
Rack-version S26361-K1159-V401 without CPU and Memory with: - 1 hot-plug power supply 700W ( Redundancy through configuration of 2nd power supply 700W ) - Four hot-plug fans ( Redundancy through configuration of Redundant hot plug Fan Kit ) - 6-port SAS backplane for 6x 3.5" hot plug SAS or SATA HD`s incl. cables for connection to the modular 8-port SAS controllers - One memory board for 4 memory DIMM pairs - 2 power cords with inlet connector for non-heating apparatus - One CPU ( first CPU ) has to be configured additionally for a base configuration - One memory kit has to be configured for a base configuration - No Rackmount Kit included ! - The Rackmount Kit or the option no Rackmount Kit has to be ordered separate
- One CPU ( first CPU ) has to be configured additionally for a base configuration - One memory kit has to be configured for a base configuration - Mouse with two pushbuttons
S26361-F3436-E4 no TPM Disable function for Trusted Platform S26361-F3436-E4 no TPM Disable function for Trusted Platform Use according to import restrictions max. 1x per system Use according to import restrictions max. 1x per system
C1
9 of 31
Mounting kits for PRIMERGY TX300 S4 - 1 pair of telescopic rails full extraction - 1 Vario carrier DC-PC-3rd party Rack allows toolless adjustable in depth and easy mounting - 1 bracket PRIMECENTER and DataCentre-Racks Mounting kit for mounting of servers in FSC 19" PRIMECENTER- racks and all server racks conforming to EIA standard EIA-310-D for 19" racks. Therefore the mounting kit is variable in depth from 704-790mm C1 PRIMERGY TX300 S4 Rack
S26361-F2735-E103 RMK_F2 TX300-S4 telescopic rail, full extraction, 1-hand-mounting consisting of - 1 pair of telescopic rails with easy-mounting-clips
S26361-F2735-E111 No Rackmount-Kit option Only for loose deliveries No mounting in Racks possible max. 1x per system
D 1x per system
S26361-F2735-E7 Cable management PC-Rack - for FSC Primecenter / Datacenter Racks - not for 3rd party 1x per system
S26361-F2201-E20 Cable arm 3rd P-Rack - for 3rd party 1x per system
In case nor cable arm is ordered, Server must be prevent of beeing pulled out.
S26361-F2735-L7 Cable management PC-Rack for loose delivery for 3rd party rack cable routing please order S26361-F2201-L20 Cable arm 3rd party racks
PRIMERGY PRIMECENTER-rack
SNP:SY-F1647E301-P Installation ex works for one server or subsystem. Hereby the rack will be delivered completely pre-mounted and all wired connections are tested. With racks 12U, 24U, 38U: Systems and components will be delivered installed in the rack With racks 46U: Systems and components will be delivered separately To be ordered only together with a PRIMERGY PRIMECENTER rack e.g.: S26361-K826-V10x refer configurator PC-Rack max. 1x per System "Rack-mounting ex factory" This service is to be ordered once per installable server/storage subsystem, in order to get the server/storage subsystem mounted into the PRIMERGY racks. In case of the 46 U PRIMERGY Rack, this service has to be ordered, to get the mounting kits and the cables installed. PRIMERGY 42/23U rack PRIMERGY Classic 19" rack is not supported
For later conversion the following kits are available: 1.) Conversion kit 3 Floor -> Rack Conversion PRIMERGY TX300 S4 base unit floorstand into base unit rack including 2 power cords with inlet connector for non-heating apparatus. Only conversion, no mounting kit. Mounting kit has to be ordered seperatly 2.) Mounting Kit FSC PC-/DC-/3rd party- Rack incl. DC- PC- bracket, no cable managment This kit will fit in server racks conforming to EIA standards EIA-310-D for 19" racks. 3.) cable management or cable arm to be ordered additionally FSC PC-/DC- Rack cable management D 3rd party- Rack cable arm or
10 of 31
1. SATA DVD 2.
Basic unit with 6-port SAS backplane for 6 3.5" SAS/SATA hard disks 2 SAS cables
Only possible for basic units with hotplug power supply S26113-F525-E10 2nd power supply 700W (hot plug) for redundancy occupies one bay for hot plug power supply max. 1x per system Only floorstand versions A second, redundant power supply requires an additional country specific power cord (section XIII)
S26361-F2544-E6 Redundant hot plug Fan Kit consists two additional Fans (hot plug) for redundancy max. 1x per system for later conversion of basic units with standard power supply Fan and PSU upgrade kit: Conversion from standard into hot plug PSU (incl. 1 PSU module) Upgrade of standard into hot plug fans (without redundancy) 1 power supply module 700W hot plug: Supplementary module S26113-F525-L22 as soon as available
S26113-F525-L10
11 of 31
E Section
II
Processor
There are 2 processor LGA771 sockets available. The first socket is always equipped with the first CPU which can be selected via configurator It is also possible to upgrade a dual-processor system later on with a second CPU Two processors with different clock frequencies are not possible A multi-processor operating system is required for a dual-processor system.
Max. two CPU`s can be selected per basic unit One of following CPUs has to be selected as first CPU for an orderable basic unit Optional second CPU has to be the same type like the first CPU Dual-Core CPU`s - 1x 64-bit Intel Xeon DP (6MB shared SLC = Second Level Cache ) and heatpipe 1333MHz Frontside Bus with 1066 or occupies socket for one CPU Xeon DP E5205 (1.86GHz/6M/1066) / 65W S26361-F3275-E186 Xeon DP X5260 (3.33GHz/6M/1333) / 80W S26361-F3275-E333 Xeon DP X5270 (3.50GHz/6M/1333) / 80W S26361-F3275-E350 Quad-Core CPU`s - 1x 64-bit Intel Xeon DP (2x6MB shared SLC = Second Level Cache ) and heatpipe 1333MHz Frontside Bus with 1066 or occupies socket for one CPU Xeon DP E5405 (2.xxGHz/2x6M/1333) / 80W S26361-F3340-E200 Xeon DP E5410 (2.33GHz/2x6M/1333) / 80W S26361-F3340-E233 Xeon DP E5420 (2.50GHz/2x6M/1333) / 80W S26361-F3340-E250 Xeon DP E5430 (2.66GHz/2x6M/1333) / 80W S26361-F3340-E266 Xeon DP E5440 (2.83GHz/2x6M/1333) / 80W S26361-F3340-E283 Xeon DP X5460 (3.16GHz/2x6M/1333) / 120W S26361-F3340-E316 Xeon DP X5470 (3.33GHz/2x6M/1333) / 80W S26361-F3340-E333 Low Voltage Dual-Core CPU`s - 1x 64-bit Intel Xeon DP (6MB shared SLC = Second Level Cache ) and passive heat sink Frontside Bus with 1066 or 1333MHz occupies socket for one CPU Xeon LV DP L5240 (3.00GHz/6M/1333) / 40W S26361-F3330-E300 Low Voltage Quad-Core CPU`s - 1x 64-bit Intel Xeon DP (2x4MB shared SLC = Second Level Cache ) and heatpipe 1333MHz Frontside Bus with 1066 or occupies socket for one CPU Xeon LV DP L5310 (1.60GHz/2x4M/1066) / 50W S26361-F3330-E160 Xeon LV DP L5410 (2.33GHz 2x6M/1333) / 50W S26361-F3330-E233 Xeon LV DP L5420 (2.50GHz 2x6M/1333) / 50W S26361-F3330-E250 Xeon LV DP L5430 (2.66GHz 2x6M/1333) / 50W S26361-F3330-E266 F
12 of 31
F Section
III
Memory
- The memory area consists of two memory boards, "Memory Board 1" and "Memory Board 2" . - "Memory Board 1" is alway configured as standard, "Memory Board 2" is an performance option. - There are 8 memory slots per memory board for max. 32GB Fully Buffered DIMM RAM available ( Fully Buffered DIMM FBD667 / PC5300F ) ( For explanation of following terms refer to section "Memory Configurations" ) - The memory area of one memory board is divided into 2 branches with 2 channels each and 4 slots per channel - The first slot of each channel belongs to memory bank 1, the second slot belongs to memory bank 2, the third slot belongs to memory bank 3 and the fourth slot belongs to memory bank 4. - Each slot can optionally be equipped with 512MB, 1GB, 2GB or 4GB FBDIMM modules No mix of modules within one memory branch allowed. - Memory upgrade is only possible per branch with modul pairs ( max. two pairs / branch) ( max. two pairs / branch)
- For each basic unit bank 1 of the first branch on Mem ory B oard 1 has to be equipped with one m em ory pair. (either 2x512MB = 1GB, 2x1GB = 2GB, 2x2GB = 4GB or 2x4GB = 8GB) Additional m em ory extensions can still be configured up to three tim es for the first m em ory board If " Mem ory B ord 2" is addionally configured, another four m em ory m odule pairs can be configured. - 4-way m em ory interleave technology for m axim um perform ance is possible with 2 m em ory m odule pairs in one m em ory bank (one pair per branch of each Mem ory B oard )
Minimum one Memory ( two modules ) = first Memory has to be selected for an orderable basic unit
S26361-F3263-E521 Memory 1GB FBD667 / PC2-5300F consisting of 2 single rank modules occupies one branch Max. 4x per 1st memory board S26361-F3263-E522 Memory 2GB FBD667 / PC2-5300F consisting of 2 dual rank modules occupies one branch Max. 4x per 1st memory board S26361-F3263-E523 Memory 4GB FBD667 / PC2-5300F consisting of 2 dual rank modules occupies one branch Max. 4x per 1st memory board S26361-F3263-E524 Memory 8GB FBD667 / PC2-5300F consisting of 2 dual rank modules occupies one branch Max. 4x per 1st memory board
4x
13 of 31
Therfore the following has to be ordered additionally to support the function "memory mirroring" :
1.) "Memory Board 2"
2.) Minimum one time the same capacity like the selected Memory on "Memory Board 1"
of the basic unit.
3.) For addtitional memory 2x the same capacity and "Memory Board 2"
The function Memory Mirroring can be configured per BIOS setup. For mirrored memory configurations the following items have to be considered: Capacity: Availability: 50% of the configured memory Maximum memory availability. Correction of double bit memory errors possible. After non-correctable errors or too many correctable errors the Mirror takes over immediately and the system remains online. Performance: Only 2-way interleave in mirror configurations possible therefore potentially not max. performance
- Function Hot Spare Mem ory . - If three or four banks of one branch are equipped with m em ory pairs, the third or fourth bank can be defined as hot spare m em ory bank. The capacity of the hot spare m em ory has to be equal or bigger than the capacity of the biggest capacity installed in the lower bank num bers.
The function Hot Spare Memory can be configured per BIOS setup. For Hot Spare Memory configurations the following items have to be considered: Capacity: Availability: 2/3 or 3/4 of the configured memory if the third or fourth bank is the hot spare bank and each bank is equipped with the same modul capacity. Less memory availability. Correction of single bit memory errors posssible. After non-correctable errors / too many correctable errors the system shuts down and during next reboot faulty memory becomes disabled. Performance: 4-way interleave possible in max. spare mode configuration with two memory boards. 4-way interleave increases system performance to maximum In general it is recommended to use identical capacities over the branches of bank 1 to bank 4 to ensure max. performance bandwidth. Memory Board 1 ( Standard ) = Memory Board 2 ( Option ) =
bank 4
FB-DIMM FB-DIMM FB-DIMM FB-DIMM
bank 4
bank 3
FB-DIMM
bank 3
FB-DIMM FB-DIMM FB-DIMM
bank 2
FB-DIMM FB-DIMM FB-DIMM FB-DIMM
bank 2
bank 1
First Memory
bank 1
FB-DIMM FB-DIMM FB-DIMM FB-DIMM
channel 0
channel 1
channel 0
channel 1
branch 0
branch 1
Memory Controllers
14 of 31
Note:
S26361-F3263-E300 Memory Board 2 for another 4* memory DIMM pairs Necessary for max. performance and Memory Mirroring max. 1x per system
for basic units with standard SV: max. 2 additional memory DIMM pairs released
2x/4x
S26361-F3263-E522 Memory 2GB FBD667 / PC2-5300F with SDDC=chipkill support consisting of 2 dual rank modules occupies one branch
Max. 4x per 2nd memory board
S26361-F3263-E523 Memory 4GB FBD667 / PC2-5300F with SDDC=chipkill support consisting of 2 dual rank modules occupies one branch
Max. 4x per 2nd memory board
S26361-F3263-E524 Memory 8GB FBD667 / PC2-5300F with SDDC=chipkill support consisting of 2 dual rank modules occupies one branch
Max. 4x per 2nd memory board
Section
IV
Graphics
Graphics Controller integrated in iRMC S2 (integrated Remote Management Controller): 1600x1200x16bpp 60Hz, 1280x1024x16bpp 60Hz, 1024x768x32bpp 75Hz, 800x600x32bpp 85Hz, 640x480x32bpp 85Hz (1280x1024x24bpp 60Hz only possible if local monitor or remote video redirection is off)
15 of 31
Memory Board 1
Bank 4 Bank 3 FB-DIMM FB-DIMM FB-DIMM FB-DIMM
Memory Board 2
FB-DIMM FB-DIMM FB-DIMM FB-DIMM Bank 4
Bank 3
Bank 2 Bank 1
FB-DIMM FB-DIMM
FB-DIMM FB-DIMM
FB-DIMM FB-DIMM
FB-DIMM FB-DIMM
Bank 2 Bank 1
Channel A
Channel B
Channel C
Channel D
Branch 1
Basically up to four different types of DIMMs pairs can be installed in Normal Mode on each Memory Board. The DIMMs of one pair must cover the same bank position on both channels of a branch. DIMM pairs must be identical with respect to size, speed, and organization. Within a branch memory DIMM pairs must be populated in bank order; Bank 1 first, Bank 2 second. The two channels on each branch operate in lock step to increase FBD bandwidth.
Example: FBD 1A = Fully Buffered DIM Module in Bank1 / Channel A 2.) Spare Mode
Memory Population
Memory Board 1 Memory Board 2
Physical View
Logical View
Memory Board 2
FB-DIMM
Sparing
FB-DIMM
Sparing
ChA
ChB
ChC
ChD
Channel A Channel B Channel C Channel D
Branch 0
Branch 1
Memory Controller
(Blackford MCH)
Branch 0
Branch 1
Memory Population
Memory Board 1 Memory Board 2
Physical View
Logical View
FB-DIMM FB-DIMM
FB-DIMM FB-DIMM
16 of 31
FB-DIMM
FB-DIMM
Both DIMM pairs in one brach must be identical with respect to size, speed, and organization. Within a branch memory DIMM pairs must be populated in bank order; Bank 1 first, spare DIMM pairs in Bank 2 second etc. The two channels on each branch operate in lock step to increase FBD bandwidth.
Physical View
Logical View
ChA
ChB
ChC
ChD
Channel A Channel B Channel C Channel D
Branch 0
Branch 1
Memory Controller
(Blackford MCH)
Branch 0
Branch 1
17 of 31
H Section
There are 3 bays (3x 1.6 * 5.25" ) for accessible drives available and three alternatives to order either standard DVD or Slim DVD. Additional possible are also configurations with Slim Floppy Disk and / or LocalView
Setup TX300 S4 by ServerStart is supported with following configurations: built in DVD or USB DVD, no Floppy disk drive: UNC Network share reachable or USB Floppy connected
1.6 * 5.25"
1x
1.6 * 5.25", anthracite bezel max.1x per system
all formats, DUAL/DL, DVD-RAM only W3K and Linux 1.6 * 5.25", anthracite bezel max. 1x per system
BD DL and all CD/DVD formats 1.6 x 5.25", anthracite bezel max. 1x per system
1.6 * 5.25"
F-D-L-HDD-Box 2 only for 3.5" HD Basic Units S26361-F2826-E301 F-D-L-Box 1 Occupies one 1.6 x 5.25" bay in the accessible bay area Offers bays for: - 1x 0.5 * 3.5" Floppy Disk Drive - 1x 0.5 * 5.25" IDE DVD-ROM - 1x LocalView option Two 0.5 * 3.5" anthracite bezels for FDD and LocalView bays One 0.5 * 5.25" anthracite bezel for 0.5 * 5.25" DVD bay max. 1 per system S26361-F2826-E101 F-D-L-HDD-Box 2 Occupies two 5.25" x 1.6" bays in the accessible bay area or Box 1
1.6 * 5.25"
1.6 * 5.25"
Local View/CSS/FD Slim DVD 1 * SAS / SATA 1 * SAS / SATA
Offers bays for: - 1x 0.5 * 3.5" Floppy Disk Drive or or - 1x LocalView option - 1x 0.5 * 5.25" IDE DVD-ROM - 2x 1 * 3.5" SAS or SATA HD`s One 0.5 * 3.5" anthracite bezel for FDD or LocalView bay One 0.5 * 5.25" anthracite bezel for 0.5 * 5.25" DVD bay Two 1 * 3,25" anthracite bezels for SAS HDD bays max. 1 per system
Air - Channel
Air - Channel
H2 H1
H3
18 of 31
H1
H2
H3
( see section XII ) S26361-F2557-E104 Local Service Display OptionKit S2 or S26361-F2557-E204 LED Display incl. mounting kit max. 1x per system ( see section XII ) S26361-F2557-E104 Local Service Display OptionKit S2 or S26361-F2557-E204 LED Display incl. mounting kit max. 1x per system
S26361-F3059-E2 Floppy disk drive 0,5" Connector: 26pin incl. description (Ger/US) 0.5 * 3.5", anthracite bezel max. 1x per system
S26361-F3059-E2 Floppy disk drive 0,5" Connector: 26pin incl. description (Ger/US) 0.5 * 3.5", anthracite bezel max. 1x per system
S26361-F3269-E1 DVD-RW supermulti slim SATA all formats, DUAL/DL, DVD-RAM only W3K and Linux 0.5 x 5.25", anthracite bezel max. 1x per system
S26361-F3531-E1 Blu-ray Combo slim SATA 6x BD-ROM, 16x DVD, 40x CD BD DL and all CD/DVD formats 0.5 x 5.25", anthracite bezel max. 1x per system
1x
S26361-F3266-E1 DVD-ROM HH SATA 16x DVD 48x CD 1.6 * 5.25", anthracite bezel max. 1x per system S26361-F3267-E1 DVD-RW supermulti HH SATA all formats, DUAL/DL, DVD-RAM only W3K and Linux 1.6 * 5.25", anthracite bezel max. 1x per system S26361-F3530-E1 Blu-ray Combo HH SATA 6x BD-ROM, 16x DVD, 40x CD BD DL and all CD/DVD formats 1.6 x 5.25", anthracite bezel max. 1x per system
If a 1.6" DVD drive is requested instead of a slim 0.5" DVD of a slim 0.5" DVD in configurations with FDD-DVDwith FDD-DVDLocalView-box or FDD-DVDwith SAS / SATA HDD-box I
1.6 * 5.25"
or
DVD
Local View/CSS/FD
DVD
Local View/CSS
Box 2
Box 1
1 * SAS / SATA -
Slim FD
1 * SAS / SATA
Air - Channel
Air - Channel
19 of 31
2x
S26361-F3270-E1 SCSI U320 Controller Adaptec SCSI Card 29320LPE PCIe x1, int: LVD HD68 ext: VHDCI 68pin max. 2x per system ext./int.
For internal SAS Backup drives an additional 4-port SAS controller has to be configured
For internal and external SCSI Backup drives an additional SCSI controller has to be configured For internal SCSI backup drives is one SCSI controller necessary. If no SCSI Backup drive is configured S26361-F2814-E12 68-Pin Kit for internal accessible SCSI drives Cable with Terminator To connect acc. drives to separate SCSI controller max. 1x per system ex works, for later installation the SCSI controller and following 68-Pin SCSI-Kit has to be ordered as lose delivery S26361-F2814-L12 68-Pin Kit for internal accessible SCSI drives Cable with Terminator To connect acc. drives to separate SCSI controller max. 1x per system
S26361-F3257-E4 4 port SAS RAID Controller LSI MegaRAID SAS 1064 no Cache, no BBU RAID 0, 1 & 1E SAS 3Gb/sec 4 internal ports PCIe x4, 160mm max. 1x per system
S26361-F3964-E3 Tape drive LTO2HH Ultrium SCSI 200GB, 24MB/s, U160 SCSI Connector: HD68 without cable incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 1x per system
S26361-F3459-E3 Tape drive LTO3HH Ultrium SCSI 400GB, 60MB/s, U320 SCSI Connector: HD68 without cable incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 1x per system
S26361-F3963-E3 Tape drive LTO4HH Ultrium SAS 800GB, 120MB/s, SAS 3Gb Connector: SATA incl. SAS cable incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 1x per system
2x
S26361-F3225-E3 Tape drive DDS Gen6 SCSI 80GB, 6MB/s, U160 SCSI Connector: HD68 without cable incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 1x per system
S26361-F2848-E3 Tape drive DDS Gen5 SCSI S26361-F2848-E31 (only for OBDR) DDS-G5 for One buttom dis. recov. 36GB, 3MB/s, U2W SCSI Connector: HD68 without cable incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 1x per system
S26361-F3325-E3 Tape drive DDS Gen6 USB 5.25" 80GB, 6MB/s, USB 2.0 Connector: USB "B" with USB cable kit incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 2x per system
S26361-F3324-E3 Tape drive DDS Gen5 USB 5.25" 36GB, 3MB/s, USB 2.0 Connector: USB "B" with USB cable kit incl. description (Ger/US) data and cleaning cartridge 1.6 * 5.25", anthracite bezel max. 2x per system
S26361-F3857-E1 RDX drive USB 5.25" internal 80-320GB, 25MB/s, USB 2.0 Connector: USB "B" with USB cable incl. description (Ger/US) without RDX cartridges 1.6 * 5.25", anthracite bezel max. 1x per system
S26361-F3324-L4 Separate parts delivery of Tape drive DDS Gen5 USB 5.25"
Following USB Components are available 1) USB DVD: 2) USB FDD: 3) USB Keyboard: External SuperMulti Drive External USB FDD (USB cable included) (USB cable included) S26341-F103-L82 S26391-F264-L226 S26381-K340-V120 S26381-K415-L100 S26391-F6047-L104
ordered separately
80GB = S26361-F3857-L80 160GB = S26361-F3857-L160 320GB = S26361-F3857-L320
4) USB Mouse: Optical Wheel Mouse Tilt USB/PS2 5) USB Memorybird: 4GB
20 of 31
J Section
J-VI
Modular Raid 0/1 and Raid5 Controller for 3.5" Hard Disks
For internal 3.5" hard disks one of the following modular RAID-controllers is required
S26361-F3257-E8 8 port SAS RAID Controller LSI MegaRAID SAS 1068 RAID 0, 1 & 1E no controller cache SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket max. 1x per system
Modular Raid 0/1 controller with IME support for SAS/SATA-HDs IME (Integrated Mirroring Enhanced) offers the RAID levels 0, 1, 1E IME is a RAID 0, 1 implementation, whereby RAID 1 can operate an odd number of hard disks. Up to 8 hard disks including one hot spare HD are possible (limited by HHD slots in system). Administration of IME is possible with the LSI Global Array Manager (GAM). Windows2000/2003 as well as SUSE and RedHat Linux are supported (Restrictions refer to Software Configurator) The SAS IME solution supports 2 independent RAID volumes.
1x
Modular Raid 5 controller for SAS/SATA-HDs RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported The RAID controller supports 6 HDDs on the 6 internal SAS ports. Tapes and optical devices (e.g. DVD) are not supported. Also there is no support of any external storage by this RAID solution. Additionally two internal 3,5" SAS or SATA HD`s in the F-D-L-HDD-Box 2 are supported by usage of the remaining 2 SAS ports.
S26361-F3257-E256 8 port SAS RAID Controller LSI MegaRAID SAS 1078 256MB Cache with ECC optional BBU SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket max. 1x per system
S26361-F3257-E512 8 port SAS RAID Controller LSI MegaRAID SAS 1078 512MB Cache with ECC optional BBU SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket max. 1x per system
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
BBU max. 2x per system possible for loose delivery please order S26361-F3257-L10
J2
21 of 31
J2 Section
J-VII
In a basic unit with a 6x 3.5" HD backplane, the remaining 2 SAS ports of the 8-port modular SAS RAID-controllers can be used for additional two SAS or SATA HD`s through the configuration of the 3.5" HD SAS / SATA extension F-D-L-HDD-Box 2 which offers extra two bays for SAS or SATA HD`s
Up to 6 or 8 ( with F-D-L-HDD-Box 2 ) 3.5" SAS or SATA hard disks can be configured. Mixed configurations with SAS and SATA 3.5" HD`s are released
S26361-F3265-E250 HD 250GB 7.2krpm 3.5" 7200rpm,<9.0 ms, 8MB Cache SATA 3Gb/s hot plug/hot replace tray max. 2x per system
S26361-F3265-E500 HD 500GB 7.2krpm 3.5" 7200rpm,<9.0 ms, 8MB Cache SATA 3Gb/s hot plug/hot replace tray max. 2x per system
S26361-F3265-E750 HD 750GB 7.2krpm 3.5" 7200rpm,<9.0 ms, 8MB Cache SATA 3Gb/s hot plug/hot replace tray max. 2x per system
S26361-F3265-E100 HD 1TB 7.2krpm 3.5" 7200rpm,<9.0 ms, 8MB Cache SATA 3Gb/s hot plug/hot replace tray max. 2x per system
6x or 8x
with SAS/SATA F-D-L-HDD-Box 2
S26361-F3204-E573 HD 73GB 15krpm 3.5" 15.000rpm,<4ms, 8MB Cache SAS 3Gb/s hot plug/hot replace tray max. 6x (or 8x) per system
S26361-F3204-E514 Hard disk 146GB 15krpm 3.5" 15.000rpm,<4ms, 8MB Cache SAS 3Gb/s hot plug/hot replace tray max. 6x (or 8x) per system
S26361-F3204-E530 HD 300GB 15krpm 3.5" 15.000rpm,<4ms, 8MB Cache SAS 3Gb/s hot plug / hot-replace Einschub max. 6x (or 8x) per system
S26361-F3204-E545 HD 450GB 15krpm 3.5" 15.000rpm,<4ms, 8MB Cache SAS 3Gb/s hot plug / hot-replace Einschub max. 6x (or 8x) per system
22 of 31
K Section
K-VI
S26361-F2826-E133 Conversion Option to 2.5" HD Basic Unit Drive Bay with one backplane for up to 12x 2.5" HD slots max. 1x per system
Section
K-VII
Modular Raid 5 controller for SAS/SATA-HDs RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported The first RAID controller supports 6 or 12 HDDs on the internal 6x or 12x SAS ports. Tapes and optical devices (e.g. DVD) are not suported. Also there is no support of any external storage by this RAID solution. A second controller is necessary if the 8x 2.5" HD Extension Box is configured
S26361-F3257-E256 8 port SAS RAID Controller LSI MegaRAID SAS 1078 256MB Cache with ECC optional BBU SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket 1x per Upgrade Option
S26361-F3257-E512 8 port SAS RAID Controller LSI MegaRAID SAS 1078 512MB Cache with ECC optional BBU SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket 1x per Upgrade Option
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
BBU max. 2x per system possible for loose delivery please order S26361-F3257-L10
2x
S26361-F2826-E113 8x 2.5" SAS HDD Extension Box Drive Bay with one backplane for up to 8x 2.5" HD slots ocupies one 3,5" acessible bay max. 1x per system
For the 8x 2.5" HD Extension Box an additional SAS controller is necessary This Extension Box is not possible with standard power supply basic units
S26361-F3257-E256 8 port SAS RAID Controller LSI MegaRAID SAS 1078 256MB Cache with ECC optional BBU SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket 1x per Extension box
S26361-F3257-E512 8 port SAS RAID Controller LSI MegaRAID SAS 1078 512MB Cache with ECC optional BBU SAS 3Gb/sec 8 internal ports PCIe x4, 160mm with combi bracket 1x per Extension box
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
BBU max. 2x per system possible for loose delivery please order S26361-F3257-L10
K2
23 of 31
K2 Section
K-VIII
Up to 12x 2.5" SAS hard disks can be configured. Additional 8x 2.5" HD`s with 2.5" HD Extension Box
S26361-F3208-E173 HD 73GB 10krpm 2.5" 10000rpm,<4,5ms, 8MB Cache SAS 3Gb/s hot plug/hot replace tray max. 12x ( or 20x ) per system
S26361-F3208-E114 HD 146GB 10krpm 2.5" 10000rpm,<4,5ms, 8MB Cache SAS 3Gb/s hot plug/hot replace tray max. 12x ( or 20x ) per system
24 of 31
L Section
IX
External 4-port SAS-controller for external SAS Disk Array S26361-F3215-E1 8 port SAS RAID Controller LSI MegaRAID SAS 8344 ELP 256MB Cache with ECC optional BBU SAS 3Gb/sec 4 internal / 4 port external PCIe x4, 198mm full height bracket max. 2x per system
S26361-F3257-E70 Cache Battery Backup Unit with 70cm cable set max. 1x per Controller
BBU max. 2x per system possible for loose delivery please order S26361-F3257-L10
S26361-F3890-E1 8 port SAS RAID Controller LSI MegaRAID SAS8880E 512MB Cache with ECC RAID 0, 1, 10, 5, 50, 6 & 60 without iBBU SAS 3Gb/sec 8 port external PCIe x4, 167mm low profile bracket max. 1x per system
S26361-F3890-E10 8 port SAS RAID Controller LSI MegaRAID SAS8880E 512MB Cache with ECC RAID 0, 1, 10, 5, 50, 6 & 60 with iBBU SAS 3Gb/sec 8 port external PCIe x4, 167mm low profile bracket max. 1x per system
SAS controller for external backup drives S26361-F3271-E1 SAS Controller 3Gb/s 8 port LSI SAS3442E-R PCIe x4, int: 4 port ext: 4 port max. 1x per system
25 of 31
M Section
Fibre Channel
Fibre Channel Controller for external storage systems S26361-F3306-E1 4GBit/s FC Controller Emulex LPe1150, full height bracket 1 channel 4GBit/sec FC Controller LC Interface for 50m Fiber PCIe x4, 170mm max. 3x per system S26361-F3306-E2 4GBit/s FC Controller Emulex LPe11002, full height bracket 2 channel 4GBit/sec FC Controller LC Interface for 50m Fiber PCIe x4, 170mm max. 3x per system S26361-F3483-E1 4GBit/s FC Controller Qlogic QLE2460, full height bracket 1 channel 4GBit/sec FC Controller LC Interface for 50m Fiber PCIe x4 170mm max. 3x per system S26361-F3483-E2 4GBit/s FC Controller Qlogic QLE2462, full height bracket 2 channel 4GBit/sec FC Controller LC Interface for 50m Fiber PCIe x4 170mm max. 3x per system
3x
For Netware only 2 controller are supported No mix and match for different Fibre Channel controllers supported except LPe1150 and LPe11002 Emulex PCI-Express Controller except QLE2460 and QLE2462 QLogic PCI-Express Controller
All controllers for the connection of external storage systems are delivered without cables. For the configuration of external cabling see the configurator for external storage systems. For Fibre Channel SAN also other componets like switches, SFPs and optical wires are orderable (for details see price liste) Internal cables and adapter are included all in the basic unit or the components.
S26361-F3961-E1 8GBit/s FC Controller Emulex LPe1250, full height bracket 1 channel 8GBit/sec FC Controller LC Interface for 50m Fiber PCIe x4, 170mm max. 3x per system
S26361-F3961-E2 8GBit/s FC Controller Emulex LPe12002, full height bracket 2 channel 8GBit/sec FC Controller LC Interface for 50m Fiber PCIe x4, 170mm max. 3x per system
26 of 31
N Section
XI
Communication / Network Two 1GBit on-board LAN Controllers Gigabit Ethernet Controller on-board 2x 1GBit BroadCom 5708 Server Adapter, BroadCom w. TOE ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel * iSCSI boot by system BIOS supported. Teaming: Failover, Load Balancing The Intel LAN Controllers 1000TX and 1000SX can be used with the on-board controller in Teaming Mode. With Broadcom on-board Gigabit Ethernet adapters for teaming the Broadcom drivers must be used. Two onboard LAN ports can likewise educate a team.
5 slots PCIe x8 ( wired x4 ) available Slot 1 = PCIe x8 ( wired x 4 ) populated by modular RAID Slot 6 is wired x8 if slot 5 is not populated Slot 3 is wired x8 if slot 2 is not populated Slot4 = PCI-X 64Bit/133MHz A) PCI-X Adapters with Teaming capability 10-1000TX /SX S26361-F3054-E1 ( Baldry II ) Gigabit Ethernet Contr. 1000SX Eth. Ctrl 1x1Gbit PCI-X Pro/1000MF LC Intel PRO/1000 MF Server Adapter PCI-X (PCI64/133), min 165 mm ext:LC-connector max. 1x per system
A PCIe x4 card can also be plugged in a PCIe x8 slot A PCIe x8 card can also be plugged in a PCIe x4 slot (mechanical x8) PCI-X and PCIe slots are not compatible!
S26361-F3053-E1 ( Everson II ) Gigabit Ethernet Controller 1000TX Eth Ctrl 1x1Gbit PCI-X Pro/1000MT Cu Intel PRO/1000 MT Server Adapter PCI-X (PCI64/133) ext: for RJ45-connector, Cat 5 max. 1x per system
S26361-F3142-E2 ( Stebbins2 resp. ) Gigabit Ethernet Controller 1000TX Eth Ctrl 1x1Gbit PCI32 PRO/1000GT Cu Intel Pro/1000 GT Desktop Adapter PCI 32 (33/66MHz), ext: for RJ45-connector, Cat 5 max. 1x per system
1x
B) Dual Port PCI-X Adapter 1000TX S26361-F3227-E2 respin ( Double Barrow II resp. ) Gigabit Ethernet Contr Dual 1000TX Eth. Ctrl 2x1Gbit PCI-X PRO/1000GT Cu Intel Pro/1000GT dual Server Adapter PCI-X (PCI64/133) ext: fr RJ45-Stecker, Cat 5 max. 1x pro System
4x
C) PCI-Express Adapter 1000TX/SX S26361-F3241-E1 (Glyndon ) Gigabit Ethernet Contr. 1000TX Eth Ctrl 1x1Gbit PCI-e Pro/1000PT Cu Intel PRO/1000 PT Server Adaptor PCIe x1 ext: for RJ45-connector, Cat 5 max. 4x per system S26361-F3242-E1 (Sheepshead Bay ) Gigabit Ethernet Contr. 1000SX Eth Ctrl 1x1Gbit PCI-e Pro/1000PF LC Intel PRO/1000 PF Server Adapter PCIe x4 ext:LC-connector max. 4x per system S26361-F3228-E1 ( Redwater ) Gigabit Ethernet Controller Dual 1000TX Eth. Ctrl 2x1Gbit PCIe PRO/1000PT Cu Intel Pro/1000PT dual Server Adapter PCIe x4 ext: for RJ45-plug, Cat 5 max. 4x per system
S26361-F3516-E1 (Shelter Island) Gigabit Ethernet Controller 1000TX Eth Ctrl 1x1Gbit PCI-e Gigabit CT DT Cu Intel Gigabit CT Desktop Adapter PCIe x1 ext: for RJ45-connector, Cat 5 max. 4x per system
S26361-F3505-E1 (Green Fountain SR) 10 Gigabit Ethernet Controller dual port LC Eth Ctrl 2x10Gbit PCIe x8 XF SR LC Intel 10 Gigabit XF SR Dual Port Server Ad. PCIe x8 ext:LC-connector max. 2x per system
D) Quad Port PCIe Adapter 1000TX S26361-F3462-E1 ( Kirkwood 2 ) Gigabit Ethernet Controller Quad 1000TX Eth. Ctrl 4x1Gbit PCIe PRO/1000PT Cu Intel Pro/1000PT quad Server Adapter PCIe x4 ext: for RJ45-plug, Cat 5 max. 3x per system
27 of 31
S26361-F2814-E8 Parallel Port Option Centronics Cable with 25-pin connector for a Centronics Parallel Port Interface max. 1x per system
28 of 31
P Section
XII
S26361-F1790-E241 iRMC S2 advanced pack integrated remote management controller activation key for graphical console redirection and remote media redirection max. 1x per system
iRMC S2 (integrated Remote Management Controller) onboard server management controller with dedicated 10/100 Service LAN-port and integrated graphics controller. The Service LAN-port can be switched alternatively on standard Gbit LAN port
S26361-F2557-E204 LED Display incl. mounting kit Customer Self Service module incl. mounting kit, anthracite bezel 0.5" x 5.25" max. 1x per system
S26361-F2557-E104 Local Service Display OptionKit S2 LCD display with installation kit 0.5" x 5.25" max. 1x per system
29 of 31
Q Section
XIII
A power cord has to be ordered for country specific floorstand versions: - once per basic unit and additional a second power cord - if an additional hot plug, redundant power supply modul is ordered
Power cord for floorstand versions for following countries: 1.8m, grey T26139-Y1740-E10 T26139-Y1742-E10 T26139-Y1743-E10 T26139-Y1744-E10 T26139-Y1745-E10 T26139-Y1746-E10 T26139-Y3850-E10 D, A, B, F, NL, FIN, N, S, E, P, RUS, TR USA, Canada Switzerland UK, IR Italy Denmark Option "no powercord", for Countries without specific cable orderable like e.g. China
Country specific power cords are not required for rack versions, except for USA &Canada. 2 power cords are shipped in a rack version with inlet connector for non-heating apparatus.
2x
T26139-Y1742-E10 USA, Canada For shipments to USA&Canada, you have to order one power cord (1,8m, grey) per power supply.
option for floorstand keyboards for floorstand versions for following countries: S26381-K397-E110 USA / international S26381-K397-E120 Germany S26381-K397-E140 France S26381-K397-E155 Sweden / Finland S26381-K397-E165 United Kingdom S26381-K397-E180 Spain S26381-K397-E185 Italy USB Keyboard: S26381-K340-E120
Power cord for optional monitor connection for the following countries: 1.8m, grey T26139-Y1740-L10 T26139-Y1742-L10 T26139-Y1743-L10 T26139-Y1744-L10 T26139-Y1745-L10 T26139-Y1746-L10 D, A, B, F, NL, FIN, N, S, E, P, RUS, TR US, CDN Switzerland UK, IR Italy Denmark
Attention: For connection of a monitor to the system an additional country specific power cord has to be ordered as option.
Options and other peripherals For other options, refer to SystemArchitect and Pricelist. These options are supplied lose with the shipment. For suitable peripherals for this product, please refer to SystemArcitect.
30 of 31
Change Report
Date
2009-03-31 2009-01-08 2008-12-17 2008-10-28 2008-10-28 2008-10-28 2008-10-28 2008-10-28 2008-10-13 2009-10-25 2008-09-30 2008-09-30 2008-09-30 2008-09-30 2008-09-27 2008-09-27 2008-09-01 2008-09-01 2008-07-14 2008-07-14 2008-07-08 2008-07-08 2008-06-25 2008-06-25 2008-05-29 2008-04-14 2008-03-11 2008-03-11 2008-02-27 2008-02-27 2007-12-20 2007-11-30
Order number
S26361-F3268-E1 S26361-F1790-E221 S26361-F3257-E4 S26361-F3963-E3 S26361-F3225-E3 S26361-F3964-E3 S26361-F3157-E3 S26361-F3505-E1 S26361-F3516-E1 S26361-F3275-E350 S26361-F3330-E266 S26361-F3340-E333 S26361-F3265-E100 S26361-F3961-E2 S26361-F3961-E1 S26361-F3531-E1 S26361-F3530-E1 S26361-F3204-E545 S26361-F3271-E1 S26361-F3890-E10 S26361-F3890-E1 S26361-F3208-E136 S26361-F3204-E130 S26361-F3330-E200 S26361-F3330-E300 S26361-F3204-E173 S26361-F3204-E114 S26361-F3330-E250 S26361-F3330-E233 S26361-F3436-E4
Changes
CD-RW / DVD ROM drive - no longer available Corrected configuration diagram: Slot 6 is wired x8 if slot 5 is not populated RemoteView Software V5.0 - no longer available 4 port SAS RAID Controller - as soon as available Tape drive LTO4HH Ultrium - as soon as available Tape drive DDS Gen6 - as soon as available Tape drive LTO2HH Ultrium LC - as soon as available Tape Kit LTO2HH Ultrium 200GB no longer available 10 Gigabit Ethernet Controller dual port LC - now available Gigabit Ethernet Controller 1000TX - now available New X5270 3.50GHz CPU now available New L5430 2.66GHz CPU now available New X5470 3.33GHz CPU now available HD SATA 3Gb/s 1TB 7.2k hot plug 3.5" - as soon as available 2 channel 8GBit/sec FC Controller now available 1 channel 8GBit/sec FC Controller now available Blu-ray Combo drive HH SATA Low Profile now available Blu-ray Combo drive HH SATA now available HD 450GB 15krpm 3.5" - as soon as available SAS Controller 3Gb/s 8 port - as soon as available new 8 port SAS RAID Controller with iBBU - as soon as available new 8 port SAS RAID Controller without iBBU - as soon as available HD SAS 3Gb/s 36GB 10k hot plug 2.5" no longer available HD SAS 3Gb/s 300GB 10k hot plug 3.5" no longer available Xeon LV DP L5335 (2.00GHz/2x4M/1333) / 50W no longer available new Low Voltage Quad-Core CPU (3.00GHz/6M/1333) / 40W - as soon as available no longer available no longer available new Low Voltage Quad-Core CPU (2.50GHz 2x6M/1333) / 50W - as soon as available new Low Voltage Quad-Core CPU (2.33GHz 2x6M/1333) / 50W - as soon as available No TPM - now available First Draft
31 of 31