Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Suitable for sloped glazed area, or roof mounted skylights Integrates with standard 1600 vertical wall Pressure equalized rain screen design Simple overlap connections "Shingled" internal channels for positive drainage Integral purlin condensation gutters Optional rafter condensation gutters Tremco VISIONstrip exterior glazing system Interior elastomeric glazing gaskets

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Structural silicone glazed (SSG) option for purlins Three rafter depths for efficient structural design Optional roll formed steel reinforcing channels Veneer type mullion for use with steel sub-structure Single glazing adapter for exterior canopies Accommodates slopes from 20 to 45 Full and half compression rings for pyramids and sloped gables
Kawneer Company, Inc. 2010

Slope, gable, pyramid, and canopy construction available Exterior / interior colour options

kawneer.com

2000 SKYLIGHT
BLANK PAGE E.C. 97911-22

OCTOBER, 2010

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

OCTOBER, 2010 E.C. 97911-22

2000 SKYLIGHT
INDEX

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

PICTORIAL VIEW . . . . . . . . . . SKYLIGHT TYPES . . . . . . . . . DETAILS . . . . . . . . . . . . . . . . . STRUCTURAL LIMITATIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . .5 . . . . . . . . . . . . . . . . . . . . . . . . . . .6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7 to 10 . . 11, 12

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF THIS PRODUCT VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION AND USE OF THIS PRODUCT AND ASSUMES NO RESPONSIBILITY THEREFOR.

Kawneer Company, Inc. 2010

Kawneer reserves the right to change or discontinue this product without notice.

kawneer.com

2000 SKYLIGHT
BLANK PAGE E.C. 97911-22

OCTOBER, 2010

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

E.C. 97911-22

OCTOBER, 2010

kawneer.com

OPTIONAL RAFTER CONDENSATION GUTTER SIMPLE OVERLAP CONNECTIONS WITH NO NOTCHES TO RAFTERS INTEGRAL PURLIN CONDENSATION GUTTER

2000 SKYLIGHT
PICTORIAL VIEW

1 9

7 5 6 3 3

SKYLIGHT TYPES

2000 SKYLIGHT

VERTICAL WITH SLOPE

2 11

1 4

RIDGE SKYLIGHT WITH SLOPED GABLE 7 3 2 10 1 PYRAMID SKYLIGHT 2 9 1 3 8 5 2 3 1 4 SINGLE SLOPE SKYLIGHT

RIDGE SKYLIGHT WITH VERTICAL GABLE

E.C. 97911-22

OCTOBER, 2010

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

E.C. 97911-22

OCTOBER, 2010

Va

2000 SKYLIGHT

rie

kawneer.com

8 1/4" (Nom.) 209.6

2
1 2

/" .5 63

82 2-0 34

SCALE 1/4 FULL SIZE

82 2-0 07

7" (Nom.) 177.8 5 1/2" (Nom.) 139.7

(Optional) 822-031 Snap-on Cover 822-120 Pressure Plate

2 SILL
822-001 822-002 822-003

2 1/2" 63.5

216-103 216-051

1 RAFTER
822-010

2
1 2

/" .5 63

82 2-0 34

3" 76.2

(Optional) Condensation Gutter

82 2-0 05

l) na ion 82 tio sat Op den ( n Co


1 2-0 0

4 1/2" 114.3 5 3/4" 146.1

Gu

3 PURLIN

tte r
82 2-1 21 82 2-0 05

DETAILS

4 HEAD

5 30 RIDGE

SCALE 1/4 FULL SIZE

6 TRANSITION

8 GABLE END 30
82 2-1 82 82 2-0 2-0 34 09 21 82 2-0 07

DETAILS

2000 SKYLIGHT

822-002 216-103 216-051

NOTE: SEE CURTAIN WALL SECTION FOR DETAILS OF 1600 WALL. Sloped Rafter 822-002 Rafter / Mullion Combinations Vertical Mullion 216-883 216-128 822-001 5 45 RIDGE 7 HIP RAFTER
82 82
822 -12

NOTE: SEE CURTAIN WALL SECTION FOR DETAILS OF 1600 WALL.

9 JAMB
822-002

221

45

12 00

822-002 216-051 216-103

OCTOBER, 2010 E.C. 97911-22

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

OCTOBER, 2010 E.C. 97911-22

2000 SKYLIGHT
DETAILS

SCALE 1/4 FULL SIZE


2 1/2" 63.5
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.
216-103 216-051

SSG OPTION

8 1/4" (Nom.) 209.6

7" (Nom.) 177.8 5 1/2" (Nom.) 139.7

3" 76.2
822-003 822-002 822-001 822-010

4 1/2" 114.3 5 3/4" 146.1

(Optional) Condensation Gutter

82

2-1

21

1 RAFTER
82
3 4

2-0

05

/" .1 19

Va rie s

82
3 4

2-0

06

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

/" .1 19

4 HEAD

82

2-0

08

3 PURLIN
3 4

/" .1 19

82

2-0

08

Kawneer Company, Inc. 2010

6 TRANSITION

216-103

216-051

2 SILL

Rafter / Mullion Combinations Sloped Rafter Vertical Mullion 216-128 216-883

NOTE: SEE CURTAIN WALL SECTION FOR DETAILS OF 1600 WALL.

822-001 822-002

NOTE: SEE 1600 SSG SECTION F2/B, PAGE 14 FOR NOTES REGARDING STRUCTURAL SILICONE SEALANT REQUIREMENTS AND STRUCTURAL LIMITATIONS.

kawneer.com

10

SCALE 1/4 FULL SIZE

3/8" 9.6

5 1/2" (Nom.) 139.7

DETAILS

6 1/8" 155.6

2 1/2" 63.5

216-103

822-004

10 COMPRESSION RING

822-013 216-051

2000 SKYLIGHT

VENEER RAFTER

H ip
Rafter

R af

te

H ip R af te r
45

822-015

Rafter

2 1/2" 63.5

6 1/8" 155.6

SINGLE GLAZING ADAPTER 11 HALF COMPRESSION RING


822-015

Rafter detail shown Purlin detail similar

45 Rafter 3 1/16" 77.8 C L

OCTOBER, 2010

E.C. 97911-22

kawneer.com

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

Kawneer Company, Inc. 2010

Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

OCTOBER, 2010 E.C. 97911-22

2000 SKYLIGHT
STRUCTURAL LIMITATIONS

11

Calculations are based on CAN3-S157 "Strength Design in Aluminum" in accordance with the National Building Code of Canada, considering combined service loads acting perpendicular to the glass plane and an allowable deflection of 1/175 of the span. Determine the service dead, wind and live loads acting perpendicular to the glass plane for the required skylight slope. The greatest of the following load combinations should be used to select the rafter required from the charts:
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor.

Deadload + Windload Deadload + Liveload Deadload + 0.7 (Windload + Liveload) The information contained here is intended as a guideline only. Consult the National Building Code of Canada and / or local codes if more detailed analysis is required. WIDTH IN METRES 0.5 1.0 1.5 2.0 WIDTH IN METRES 0.5 1.0 1.5 2.0 WIDTH IN METRES 0.5 1.0 1.5 2.0

21 20 19 18 17 16 15 14 13 12 11 10

21 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 20 19 18 17 16 15 14 13 12 11 10 9 LENGTH IN METRES 8 LENGTH IN FEET 7 6 5 4

21 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 20 19 18 17 16 15 14 13 12 11 10 9 LENGTH IN METRES 8 LENGTH IN FEET 7 6 5 4

6.0 5.5 A 5.0 B C D E F 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1 2 3 4 5 6 7

B C D E F

A B C D E F

Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement.

9 8 LENGTH IN FEET 7 6 5 4 1 2 3

WIDTH IN FEET

WIDTH IN FEET

WIDTH IN FEET

Kawneer Company, Inc. 2010

3" 76.2

41/2" 114.3

822-003

I = 3.15 (1.31 x 10 6 mm 4 ) S = 1.26 in 3 (2.06 x 10 4 mm 3 )

in 4

822-002

5 3/4" 146.1

I = 6.91 in 4 (2.88 x 10 6 mm 4 ) S = 2.20 in 3 (3.60 x 10 4 mm 3 )

822-001

I = 11.64 (4.85 x 10 6 mm 4 ) S = 3.15 in 3 (5.15 x 10 4 mm 3 )

in 4

A = 20 p.s.f. (0.96 kPa.) B = 30 p.s.f. (1.44 kPa.) C = 40 p.s.f. (1.92 kPa.) D = 50 p.s.f. (2.40 kPa.) E = 70 p.s.f. (3.36 kPa.) F = 90 p.s.f. (4.31 kPa.)

822-005

I = 1.25 in 4 (5.20 x 10 5 mm 4 ) S = 0.71 in 3 (1.16 x 10 4 mm 3 ) I = 0.79 in 4 (3.28 x 10 5 mm 4 ) S = 0.71 in 3 (1.17 x 10 4 mm 3 )

822-006

NOTE: THE CURVED LINES ON THE GRAPHS REPRESENT THE RAFTER LIMITATIONS. THE VERTICAL LINES REPRESENT THE MAXIMUM RAFTER CENTRES BASED ON THE PURLIN LIMITATIONS.

kawneer.com

LENGTH IN METRES

12

2000 SKYLIGHT
STRUCTURAL LIMITATIONS

OCTOBER, 2010 E.C. 97911-22

Calculations are based on CAN3-S157 "Strength Design in Aluminum" in accordance with the National Building Code of Canada, considering combined service loads acting perpendicular to the glass plane and an allowable deflection of 1/175 of the span. Determine the service dead, wind and live loads acting perpendicular to the glass plane for the required skylight slope. The greatest of the following load combinations should be used to select the rafter required from the charts:
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Kawneer Company, Inc. 2010

Deadload + Windload Deadload + Liveload Deadload + 0.7 (Windload + Liveload) The information contained here is intended as a guideline only. Consult the National Building Code of Canada and / or local codes if more detailed analysis is required. WIDTH IN METRES 0.5 1.0 1.5 WIDTH IN METRES 0.5 1.0 1.5 WIDTH IN METRES 0.5 1.0 1.5 A

24 23 22

2.0 7.0 6.5

24 23 22

2.0 7.0

24 23 22 6.5

2.0 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 LENGTH IN METRES

21 20 19 18 17 16 15 14 LENGTH IN FEET 13 C D B

21 20 19 C D

21 20 19

C D

6.0 5.5 5.0 4.5 LENGTH IN METRES 4.0 3.5

6.0 5.5

18 17 16 15 14 LENGTH IN FEET 13 F E

18 17 16 15 14 LENGTH IN FEET 13

E F

5.0 4.5 4.0 3.5 LENGTH IN METRES

12 11 1 2 3 4 5 6 7

12 11 1 2 3 4 5 6 7

12 11 1 2 3 4 5 6 7

10

10

10

WIDTH IN FEET

WIDTH IN FEET

WIDTH IN FEET

5 3/4" 146.1

5 3/4" 146.1

822-001

822-001

5 3/4" 146.1

216-132

Steel Reinforcing

216-132 216-133

Steel Reinforcing

216-132 216-133 216-134 822-001

Steel Reinforcing

Aluminum I = 11.64 in 4 (4.85 x 10 6 mm 4 ) S = 3.15 in 3 (5.15 x 10 4 mm 3 ) Steel I = 4.73 in 4 (1.97 x 10 6 mm 4 ) S = 1.94 in 3 (3.18 x 10 4 mm 3 )

Aluminum I = 11.64 in 4 (4.85 x 10 6 mm 4 ) S = 3.15 in 3 (5.15 x 10 4 mm 3 ) Steel I = 8.54 in 4 (3.55 x 10 6 mm 4 ) S = 3.63 in 3 (5.95 x 10 4 mm 3 )

Aluminum I = 11.64 in 4 (4.85 x 10 6 mm 4 ) S = 3.15 in 3 (5.15 x 10 4 mm 3 ) Steel I = 11.39 in 4 (4.74 x 10 6 mm 4 ) S = 5.01 in 3 (8.22 x 10 4 mm 3 )

A = 20 p.s.f. (0.96 kPa.) B = 30 p.s.f. (1.44 kPa.) C = 40 p.s.f. (1.92 kPa.) D = 50 p.s.f. (2.40 kPa.) E = 70 p.s.f. (3.36 kPa.) F = 90 p.s.f. (4.31 kPa.)

822-005

I = 1.25 in 4 (5.20 x 10 5 mm 4 ) S = 0.71 in 3 (1.16 x 10 4 mm 3 ) I = 0.79 in 4 (3.28 x 10 5 mm 4 ) S = 0.71 in 3 (1.17 x 10 4 mm 3 )

822-006

NOTE: THE CURVED LINES ON THE GRAPHS REPRESENT THE RAFTER LIMITATIONS. THE VERTICAL LINES REPRESENT THE MAXIMUM RAFTER CENTRES BASED ON THE PURLIN LIMITATIONS.

kawneer.com

Вам также может понравиться