Fire

Conventional Detectors
DATA SHEET
CPD321 / CPT341 / CFR330 / CMT360 CHT390 / MPD821 / MPT951/ MFR830 / MMT860 / MHT890 / FXN533 FXN632 / FXN525 / FXN524 / FXN526

Cooper offers a comprehensive range of conventional detectors that are compatible with Cooper, Menvier and JSB conventional control panels.

Benets and Features


> > > > > > > LPCB 3rd party approved / CPD approved Low profile design 360 viewable LED design Removable detector chamber for cleaning Common mounting base New enhanced detectors feature dual LEDs, Drift compensation and chamber monitoring (Optical & Photo-Thermal)

Technical Specications
Model Description CPD approved product Standards CPD321 / MPD821 FXN533 Optical detector 0832CPD0633 EN54: Pt 7; 2000 + A1 2002 CPT341 / MPT951 FXN632 Photo-themal detector 0832CPD0629 EN54: Pt 7; 2000 + A1 2002 EN54 Pt 5; 2000 + A1 2002 Area coverage System wiring Indication Mounting Detetion Mode Operating voltage Max stand by current Max Start up current Max alarm current Heat class Alarm temperature Environmental IP rating Operating temperature Humidity EMC Physical Construction Colour Dimensions Excluding base (Dia x H) Including base (Dia x H) Compatibility 100mm x 45mm 100mm x 43mm 101mm x 55mm Conventional re systems ABS White -20C to 60C -20C to 45C IP40 -20C to 60C 0 to 95% non condensing CE marked -20C to 60C -20C to 75C NA NA A2S 60C 340A 340A 25mA A2R 60C BS 77C CS 92C light scatter principle light scatter principle heat sensitive element 15 to 30 V dc 30A NA 100m (subject to local standard) 2 core 360 visibility light pipe Surface mount CDBB300, FXN520 base heat sensitive element 50m (subject to local standard) CFR330 / MFR830 FXN525 Heat detector (fast) 0832CPD0233 CMT360 / MMT860 FXN524 Heat detector (med) 0832CPD0236 EN54: Pt 5; 2000 + A1 2002 + A1 2002 CHT390 / MHT890 FXN526 Heat detector (high) 0832CPD0237

Wiring Diagram - Standard Conventional Base


+V e
+
Remote Indicator LED (optional)

+
Conventional Zone Fire Alarm Panels

4 2 3
2

-Ve

Earth screen of cable to be continuous between detectors

Product Codes
Conventional optical detector Conventional photo-themal detector Conventional heat detector (Fast) Conventional heat detector (Med) Conventional heat detector (High) Conventional mounting base CPD321 / MPD821 / FXN533 CPT341 / MPT951 / FXN632 CFR330 / MFR830 / FXN525 CMT360 / MMT860 / FXN524 CHT390 / MHT890 / FXN526 CDBB300 / FXN520

Cooper Lighting and Safety Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB www.cooperfire.com
Sales T: +44 (0)1302 303 999 F: +44 (0)1302 303 333 E: sales@cooperfire.com