COMPETANT PERSON Under Section 2 (ca) of the Factories Act. 1948 RECOGNITION NO: CP (O) NO 55 (G)
PLOT NO: 1205 / A, NAYAPALLI, BHUBANESWAR - 751012 TEL: 0674 2560284, CELL: 94371 32223
01.10.2010
Report of periodic examination of lifting machines, chains, ropes and lifting tackles
as per FORM 7 - A
[As Prescribed under Rule 55-C , Sub-section (2) of Section 29, Factory Rules, 1950] 1 2 Name of Occupier of Factory Address of the factory:
Mr. B. K. Dash M/s East End Technologies Pvt. Ltd. Plot No:133-137 IDCO Indl. Estate, Choudwar, Cuttack.
H.O.T Single Girder Goliath Crane, Id. No: GOLIATH/CRANE/5T/EETPL-01 Make: EETPL, Capacity: 5T, Span: 15mtrs, Height of Lift: 4.5mtrs Mfg Sl. No: Not Available Location : EETPL FACTORY PREMISES Yes
Distinguishing number or mark, if any, and description sufficient to identify the lifting machine, chain, rope or the lifting tackle:
Design and construction: Are all the parts of hoist or lift of good mechanical construction, sound material and adequate strength ( so far as ascertainable)? Date when the lifting machine, chaain, rope or lifting tackle was first taken into use in the factory: Date of construction or reconstruction (if ascertained) Date and number of certificate relating to any test and examination made under Rules 55-A and 55-G together with the name and address of the person who issued the certificate: Date of each periodical thorough examination made under Rule 55-F and the name of examiner: Date of annealing or other heat treatment of the chain and other lifting tackle made under Rule 55-E and by whom it was carried out: Particulars of any defects affecting the safe working load found at any such thorough examination or after annealing and of the steps taken to remedy such defects: Visual Inspection (for Maintenance):
2009
6 7
Not any
Not any
10
Nothing observed
11
Are the following parts of the hoists or lift properly maintained and in good working order? If not state what defects have been found.
(a) Encloser of Hoistway or Liftway (b) Landing gates and cage gates(s) (c) Interlocks and cage - gate(s) the landing gates and
NA NA NA NA NA
(d) Other gate fastenings (e) Cage and platform and fitting, guides and buffers, interiors of the hoistway or liftway (f) Overrunning devices (g) Suspension ropes attatchments or chains and their
NA Good condition NA
(h) Safety gear, I.e., arrangement for preventing fall of platform or cage brakes (i) Brakes (j) Worm or spur gearing (k) Other electrical equipment (l) Other parts 12 13 What parts (if any) were inaccessible Repairs, renwal or alteration (if any) required and the period within which they should be executed. Load Testing: (a) Static tests
14
6.25T held at a height of 0.1mtr above ground for 10min 5.5T lifted upto 5.5 mtr and lowered Deflection at 5T:10mm at centre span Movement in Long travel, with 5.5T load were found satifactory and stable. No overturning tendencies were observed. Below 5T.
15
Maximum safe working load subject to repairs, renewals or alterations (if any) specified in item 5 Others
16
I certify that on 01.10.2010, the above HOT GOLIATH CRANE was thoroughly cleaned to the extent possible and made accessible for through examination and for such tests as were necessary to ascertain the health of the above HOT GOLIATH CRANE. I have thoroughly examined this HOT GOLIATH CRANE and that the above is a correct report of the result. Signature: Qualification: Address: Date: B.Tech (Hons). Competant Person Regn no: CP(O)NO 55(G) Plot No: 1205/A, P.O: Nayapalli, Bhubaneswar - 751012. 01.10.2010
PLOT NO: 1205 / A, NAYAPALLI, BHUBANESWAR - 751012 TEL: 0674 2560284, CELL: 94371 32223
01.10.2010
Report of periodic examination of lifting machines, chains, ropes and lifting tackles
as per FORM 7 - A
[As Prescribed under Rule 55-C , Sub-section (2) of Section 29, Factory Rules, 1950] 1 2 Name of Occupier of Factory Address of the factory:
Mr. B. K. Dash M/s East End Technologies Pvt. Ltd. Plot No:133-137 IDCO Indl. Estate, Choudwar, Cuttack.
H.O.T Single Girder Goliath Crane, Id. No: GOLIATH/CRANE/5T/EETPL-02 Make: EETPL, Capacity: 5T, Span: 4mtrs, Height of Lift: 3mtrs Mfg Sl. No: Not Available Location : EETPL FACTORY PREMISES Yes
Distinguishing number or mark, if any, and description sufficient to identify the lifting machine, chain, rope or the lifting tackle:
Design and construction: Are all the parts of hoist or lift of good mechanical construction, sound material and adequate strength ( so far as ascertainable)? Date when the lifting machine, chaain, rope or lifting tackle was first taken into use in the factory: Date of construction or reconstruction (if ascertained) Date and number of certificate relating to any test and examination made under Rules 55-A and 55-G together with the name and address of the person who issued the certificate: Date of each periodical thorough examination made under Rule 55-F and the name of examiner: Date of annealing or other heat treatment of the chain and other lifting tackle made under Rule 55-E and by whom it was carried out: Particulars of any defects affecting the safe working load found at any such thorough examination or after annealing and of the steps taken to remedy such defects: Visual Inspection (for Maintenance):
2009
6 7
Not any
Not any
10
Nothing observed
11
Are the following parts of the hoists or lift properly maintained and in good working order? If not state what defects have been found.
(a) Encloser of Hoistway or Liftway (b) Landing gates and cage gates(s) (c) Interlocks and cage - gate(s) the landing gates and
NA NA NA NA NA
(d) Other gate fastenings (e) Cage and platform and fitting, guides and buffers, interiors of the hoistway or liftway (f) Overrunning devices (g) Suspension ropes attatchments or chains and their
NA Good condition NA
(h) Safety gear, I.e., arrangement for preventing fall of platform or cage brakes (i) Brakes (j) Worm or spur gearing (k) Other electrical equipment (l) Other parts 12 13 What parts (if any) were inaccessible Repairs, renwal or alteration (if any) required and the period within which they should be executed. Load Testing: (a) Static tests
14
6.25T held at a height of 0.1mtr above ground for 10min 5.5T lifted upto 5.5 mtr and lowered Deflection at 5T:10mm at centre span Movement in Long travel, with 5.5T load were found satifactory and stable. No overturning tendencies were observed. Below 5T.
15
Maximum safe working load subject to repairs, renewals or alterations (if any) specified in item 5 Others
16
I certify that on 01.10.2010, the above HOT GOLIATH CRANE was thoroughly cleaned to the extent possible and made accessible for through examination and for such tests as were necessary to ascertain the health of the above HOT GOLIATH CRANE. I have thoroughly examined this HOT GOLIATH CRANE and that the above is a correct report of the result. Signature: Qualification: Address: Date: B.Tech (Hons). Competant Person Regn no: CP(O)NO 55(G) Plot No: 1205/A, P.O: Nayapalli, Bhubaneswar - 751012. 01.10.2010