MV network management
Easergy G200
Basic functions
b Remote monitoring of up to 9 overhead lines (currents, faults, voltage losses, etc.) b RTU with open protocol (DNP3, IEC 870-5-101) b Communication via GSM/GPRS or CDMA b Pole-mounted or inside RTU b External power supply or solar panel
The G200 basic functions are: b Date and time stamping of all events from Flite 116 b Sending all the requested events to the W500 maintenance software or/and to the SCADA b Remote parameter setting of Flite 116 units b Local parameter setting of Flite 116 and G200 units via the RS232 local port b Storage capacity: 100 stamped events.
Description
The G200 is available in 3 housings: b Pole-mounted enclosure, able to house a battery and a battery charger, with external AC supply (ref. G200 PF) b Pole-mounted small size box, with external DC supply, either from solar panel or other (G200 GF) b To be connected to another RTU or part of a switch local control cabinet (G200 SF). The main board includes: b A short range low power spread spectrum radio for communication with the Flite 116 b For long range communication: v one communication medium with its embedded modem (GSM/GPRS/CDMA) or v one RS232 port for external communication. b One RS232 local parameter setting port b 6 digital inputs, for alarm information to SCADA or W500 maintenance software b 3 digital dry contact outputs set to repeat phase faults (phase A, B, or C) from Flite 116 or short range communication faults or battery faults for transmission by an external RTU.
PE55844
PE55848
PE55843
G200 characteristics
Spread spectrum low power licence-free 915-928 MHz FCC part 15.249 and AS/NZS 4268:2003 approved radio Embedded GSM/GPRS modem DNP3, IEC 870-5-101 b I min, I max, I mean and I inst b MV presence statistics 9 phases (9 Flite 116) 100 m b Earth fault indication (phase A, B, or C), (beginning time, ending time) b Phase fault indication (phase A, B, or C), (beginning time, ending time) Transient fault indication and time stamping b Voltage loss indication (phase A, B, or C) and time stamping b Voltage recovery time indication Communication with Flite 116 no.x faulty (after a number of attempts) and time stamping Battery low in Flite 116 no.x and time stamping Battery low in G200 and time stamping (only for G2PF) External AC supply off (only for G2PF) 6 digital inputs 3 relay outputs 220 Vac/1 A 100 Remote via W500 or SCADA 90 to 230 Vac or external 12 Vdc supply or solar panel 6 V when solar powered, 12 V when AC supply 25C to +70C 40C to +85C Large enclosure 430 x 330 x 200 8 kg IP 54 IK 7
Long range communications Communication media Communication protocol Measurements Type HV line monitoring Number of HV lines monitored per G200 Max. distance with Flite 116 Earth fault Phase fault or Imax Transient fault detection if enabled Voltage loss Equipment monitoring Local radio communication faulty Flite 116 battery alarm G200 battery alarm AC supply alarm RTU inputs/outputs Inputs Outputs Local archive Date and time stamped events and measures Downloading of local archive Power supply Supply Battery Environment Operating temperature Storage temperature Mechanical Dimensions in cm Net weight in kg Protection level Standards Vibrations and shocks test EMI / EFI immunity Salt spray and humidity tests
SCADA
Protocols: DNP3
PE55842
PE55849
G200 GF
G200 PF
PE55850
G200 SF
IEC 68-2-6 and 68-2-29 IEC 801-3 and FCC Part 15 IEC 68-2-11 and 68-2-30
PE55845
Other references b Solar panel, without battery: GS612 10 W b GSM pad antenna with 3 m cord: ANT G1 b W500 network maintenance software with DNP3 protocol: W500-DNP3
Reference example: G2 Enclosure size: PF large - IP 54 GF medium - IP 41 SF small - IP 21 GF - 915 AZ D IZ 1 - Embedded interface: G GSM 900 - 1,800 MHz I GPRS 900 - 1,800 MHz 2 RS232 P GSM 1,900 MHz Q GPRS 1,900 MHz 2 - External modem device: Z none
Up to 9 Flite 116
Short range radio frequency: 915 902-928 Mhz 1 - Power supply: A external 6/12 Vdc B 110/230 Vac 2 - Back-up battery: A 7 Ah sealed lead battery (G2 PF) Z no battery
As standard, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper Publishing : Schneider Electric Industries SAS Production : Schneider Electric Industries SAS Printing : Imprimerie du Pont de Claix/JPF - Made in France 08-2007
ENMED305016EN