1- As per figure 1 below, it is important to choose plane for 2D model analysis and 3D for 3D analysis, in this example choose 2D. 2- Fill the white right rectangular with model name and determine the location for the saved analysis. 3- It is very important to choose the input units for dimensions and loads before starting the analysis. 4- Click next.
Step 4
5- Choose add beam or use structure wizard to use the STAAD template for simple structure. 6- Finish.
Step 5
Step 6
7- Choose the plane of axis (X-Y). 8- In construction lines, choose x-right to be 1 with spacing 10m any right 1 with spacing 0m (simple beam). 9- Snap beam between the two shown nodes. Step7 Step 8
10- Assign supports pinned for the beam from support page icon as below.
11- Define separate load cases for all the cases of loading from the load page icon. 12- From the primary load, define the load cases from DL, LL, Finishes, windetc. 13- Note: for the use of auto load combination, must define the loading type correctly (dead, live, wind, temperature .etc) to enable the STAAD to recognize the type of load implemented.
Primary
Load No.
Loading type
Load page
Load type
Add to assign
14- Note: When assigning concentrated load force, this force will not be copy, rotate or mirror, to avoid this define the concentrated load from member load.
Member load
concentrated force
load value
15- Assign all the different loads on the beam element. 16- Note: Finishes and superimposed load is to be added to dead load case in case for adopting the automatic load combination to use the load type dead load (no loading type named finishes, has to be defined as dead). 17- Define the load combinations manual or auto combination.
Comb. No.
Combination title
Combination
Auto comb.
Combination code
18- Assign the preliminary beam section profile from property page. Section database for rolled section Property page
Or from below
Run analysis
Beam to be copy
2- Link between the two copied beams using add beam icon from the toolbar as below.
3- Use command copy/repeat to add columns, use repeat command as below. - Mark the nodes which will connect to the columns. - Click on the command translational repeat. - Enter the distance in Y-direction with ve sign to repeat downward. - Mark the link step button option to add beams between the repeated joints. Select the nodes Translation repeat command No.of step
Choose direction
Distance
Link step
4- Delete the supports from the upper nodes using the toggle assign command in the support page.
Supports page
No support command
Mark nodes
5- To add secondary beam use the following: - Insert nodes on the beams using insert node icon then link between the nodes by add beam option. - Use add beam perpendicular icon to add beams between joint and perpendicular on the front beam. - Use add beam between mid points icon to add beam directly in the middle without inserting nodes.
6- Adding beam releases to the beam as shown below from the specification page.
Specification page
7- How to save view: - TO save columns view for example, mark the columns. - Click on view then choose view selected object only. - Click on view view management save view Click view Select view selected object only
View management
Selected columns
Save view
8- To recall the view, click write click and choose open view
9- List of checks before run the 3D model as follows: - Check multiple structure - Check duplicated nodes, members, & plates. - Check orphan nodes. - Check zero length members. - Check collinear members. - Other checks for plates, .etc.
Click on tool
List of checks
10- Load list command for the design on combination load only. (Important: check at that load list command is after per form analysis command).
Click on command
Loading
Load combination
Editor icon
11- For design, click on design command on the vertical toolbar then choose the design code.
Choose steel
Click on design
Define parameters
CB=0
TRACK=2
BEAM=1
TORSION=1
13- Lateral torsion buckling unsupported length is to be written in the editor manual after the LY.
Add UNL
14- Before the analysis change the plane order to space in the editor.
Space
15- From the symbols and labels icon choose design results, show diagram them show value to see the design unit check on the STAAD screen.
Design result
Show value
Show values
Show diagram
16- To select the unsafe members: click on select, select by specifications, then select failed members.
Select command
By specification
Definition
Load page
Seismic definition
2- As per the UBC tables, enter the data as follows: Zone: depend on the zone number 1, 2A, 2B, Importance factor: for ordinary building I=1 RW in X or Z directions: depend on the resisting frame type in X or Z direction (moment resisting frame, braced frame,..)as per table 16-N. Soil profile type: depend on the soil type as per the geotechnical report and from table 16-J fr soil profile types (SA=1, SB=2, SC=3,..). Near source factor Na, & NV: to be calculated for zone4 only as per table 16-S, 16-T. CT value: constant equal 0.0853 for steel moment resisting frame, & 0.0488 for all other building as per page 2-14. Period in X and Z direction: not entered for the first run and will be adjusted after viewing the results in the upcoming steps. 3- Click ADD.
4- Add the loads as follows: Self weight. Add joint weight if any ( to be after self weight and before any other load). Add member weight if any. NOTE: Member weight and joint weight can be taken copy and paste from the dead load and 25% of the live load (if needed) in the same formula of the member weight.( member load is to be replaced by member weight and erase GY to be UNI only, joint load is to be joint weight and change FY to weight as per the attached shots.
Format changed
5- Return to Staad screen. 6- Add two new load cases for sis-x and sis-z and define the loading type (seismic) for the auto load combination. Add new load cases for sis
7- Click on seismic x and choose Add then choose seismic. 8- The factor is to be calculated from UBC page 2-13 with range 1.0<R<1.5 depending on the column shear percentage w.r.t the total horizontal force. 9- For using the IBC, enter R=1 for zone 1 to 2B, and 1.5 for zone 3& 4. 10- Repeat the above steps 7& 8 for seismic z. Choose X Click on SIS X
11- Enter the editor, and write the command perform analysis and command change under seismic X & Z manually .
12- NOTE: the seismic cases should be the first load cases above all other cases, so cut and paste the two cases as below.
13- Run the model and open the output. 14- Check the time Ta and Tb as below: Ta can be replaced by Tb under the below conditions: If Tb > Ta then take Tb > 1.4 Ta If Ta > Tb then take Ta After increasing the Time re-run the model with the new T as below.
Ta X 1.4 =0.228 < 0.538 then T user = 0.228 15- Re-enter the T user with 0.228.
Take pictures
3- From button of Report Setup we can control the input / output / pictures we need to appear it in our report.
Available options
selected options
4- Control steel design output to show summary design only or design with full detail.
5- We can control the picture (sketch) size & select full page option.
Delete picture
size controller
6- To export the results to MS Word file; if you want to show outputs the model should be run and in the post processing mode. 7- Go to FILE menu, then chose EXPORT REPORT, then MS Word file.
File
Export report
MS Word file
8- Click SAVE.