Вы находитесь на странице: 1из 64

Heavy Duty Hydraulic Cylinders

Series 2H

Catalog HY08-1114-1/NA

Section A Overview

Section A
Series 2H
Heavy Duty Hydraulic Cylinders
1.50" Through 6.00" Bore
Performance

Specifications and Mounting Styles

Cylinder Features

4-5

Application Check List

Mounting Styles & Tips for Applying

2H Cylinder Model Code & How To Order

8-9

Rod End Styles and Dimensions

10-11

TD, TB, TC Mount Dimensions

12

J Mount Dimensions

13

JB Mount Dimensions

14

JJ Mount Dimensions

15

H Mount Dimensions

16

HB Mount Dimensions

17

HH Mount Dimensions

18

C Mount Dimensions

19

F Mount Dimensions

20

BB Mount Dimensions

21

D Mount Dimensions

22

DB Mount Dimensions

23

DD Mount Dimensions

24

DE Mount Dimensions

25

SB Mount Dimensions

26

Double Rod End Cylinders

27

2HD & 3HD Bolt-On Gland Option

28


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Performance

Heavy Duty Hydraulic Cylinders


Series 2H

Parker Series 2H
Heavy Duty Hydraulic Cylinder
Series 2H cylinders set the standard for performance,
durability, and trouble free operation. Parker superior design,
the use of high quality materials and stringent manufacturing
practices provide all customers with long cylinder service life
and reduced operating costs. Patented design features such
as the Jewel rod gland, hard chrome plated piston rods, and
stepped cushions provide increased machine productivity
through reduced downtime, faster cycle times, and improved
system efficiency. Every Parker cylinder is individually tested
before leaving our plant to assure proper performance and
leak free operation. All Parker Cylinder products carry an 18
month warranty.
Select Parker Series 2H cylinder for your hydraulic cylinder
requirements. Parker Series 2H will provide the value and
performance you need for all of your industrial hydraulic
application demands.


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Specifications

Standard Specifications

Heavy Duty Service ANSI/(NFPA) T3.6.7R2 - 1996



Specifications and Mounting Dimension Standards
Standard Construction Square Head Tie Rod Design
Nominal Pressure 3000 psi1
Standard Fluid Hydraulic Oil
Standard Temperature -10F to +165F 2
Bore Diameters 1.50" through 6.00" (Larger sizes available)

Piston Rod Diameter .625" through 4.000"


Mounting Styles 18 standard styles at various
application ratings
Strokes Available in any practical stroke length
Cushions Optional at either end or both ends of stroke.
Float Check at cap end.
Rod Ends Four Standard Choices Specials to Order

In line with our policy of continuing product improvement,


specifications in this catalog are subject to change.
Note: Series 2H Hydraulic Cylinders fully meet ANSI/(NFPA) T3.6.7R2
- 1996 Specifications and Mounting Dimension Standards for Square
Head Industrial Fluid Power Cylinders.

1
If hydraulic operating pressure exceeds 3000 psi, send application
data for engineering evaluation and recommendation. See Section E
for actual design factors.
2
See Section E for higher temperature service.

Available Mounting Styles


Basic

Tie Rods Extended Head End


Style T
1.50" - 6.00"

(NFPA MX0)

Tie Rods Extended Cap End

Style TB
1.50" - 6.00"

(NFPA MX3)

Head Rectangular Flange

(NFPA MF1)

Head Square Flange

Head Rectangular

Style JB
1.50" 6.00"

(NFPA MF6)

Side Lug

Style HH
1.50" - 6.00"

(NFPA MP1)

Cap Trunnion

Style DE
4.00" - 6.00"

Intermediate Fixed Trunnion

Style DB
1.50" - 6.00"

Style D
1.50" - 6.00"

(NFPA MT2)

(NFPA MT1)

HD Intermediate Fixed Trunnion

Style F
1.50" - 6.00"

(NFPA MS4)

(NFPA MS2)

Head Trunnion

Style BB
1.50" - 6.00"

Side Tapped
Style C
1.50" - 6.00"

(NFPA ME6)

Cap Fixed Clevis

Style H
1.50" - 6.00"

(NFPA MF2)

(NFPA ME5)

Cap Rectangular

Style HB
1.50" - 6.00"

Cap Rectangular Flange

Style JJ
1.50" - 6.00"

(NFPA MF5)

Cap Square Flange

Style TD
1.50" - 6.00"

(NFPA MX1)

(NFPA MX2)

Style J
1.50" - 6.00"

Tie Rods Extended Both Ends

Style TC
1.50" - 6.00"

Style DD
1.50" - 6.00"

(NFPA MT4)
Double Rod Cylinders

Spherical Bearing

Style KT Shown
1.50" - 6.00"

Style SB
1.50" - 6.00"

Most of the above illustrated


mounting styles are available
in double rod cylinders.

(NFPA MT4)


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Features and Benefits

The inside story on why


Series 2H is your best choice in
heavy duty hydraulic cylinders

High Strength Tie Rods


Made from 100,000 psi minimum
yield steel with rolled threads for
added strength.

Ports SAE O ring ports


are standard.

Primary Seal TS-2000 Rod Seal is a proven


leakproof design completely self-compensating
and self-relieving to withstand variations and
conform to mechanical deflection that may occur.

Optional Ports

Ports NPTF ports are


optional at no extra charge.
Oversize NPTF and SAE ports
are available at extra charge.

Jewel Rod Gland Assembly Externally


removable without cylinder disassembly. Long
bearing surface is inboard of the seals, assuring
positive lubrication from within the cylinder. An
o-ring is used as a seal between gland and head,
and also serves as a prevailing torque-type lock.
Secondary Seal Double-Service
Wiperseal (Hannifin Patent #2907596)
wipes clean any oil film adhering to the
rod on the extend stroke and cleans the
rod on the return stroke.
Piston Rod Stud Furnished on 2.000"
diameter rods and smaller when standard
style #4 rod end threads are required.
Studs have rolled threads and are made
from high strength steel. Anaerobic
adhesive is used to permanently lock the
stud to the piston rod.
Piston Rod Medium carbon steel, induction casehardened, hard chrome-plated and polished to 10 RMS
finish. Piston rods are made from 90,000 to 100,000 psi
minimum yield material in .625" through 4.000" diameters.
Larger diameters vary between 57,000 and 90,000 psi
minimum material, depending on rod diameter.

Parkers Exclusive Stepped


floating cushions combine
the best features of known
cushion technology.

End Seals Pressureactuated cylinder body-tohead and cap o-rings.


Steel Head Bored and
grooved to provide concentricity
for mating parts.

steps. The deceleration cushion plunger curves shape comes


very close to being theoretical, with the exception of the last
1
/2 inch of travel. This is a constant shape in order to have some
flexibility in application. The stepped cushion design shows
reduced pressure peaks for most load and speed conditions,
with comparable
reduction of
objectionable
stopping forces
being transmitted
to the load and
the support
structure.

Deceleration devices or built-in cushions are optional and can


be supplied at head end, cap end, or both ends without change
in envelope or mounting dimensions. Parker cylinder cushions
are a stepped design and combine the best features of known
cushion technology.
Standard straight or tapered cushions have been used in
industrial cylinders over a very broad range of applications.
Parker research has found that both designs have their
limitations.

All Parker
Hannifin cushions
are adjustable.

As a result, Parker has taken a new approach in cushioning of


industrial hydraulic cylinders and for specific load and velocity
conditions have been able to obtain deceleration curves that
come very close to the ideal. The success lies in a stepped
sleeve or spear concept where the steps are calculated to
approximate theoretical orifice area curves.

The Series 2H
cylinder design
incorporates
the longest
cushion sleeve
and cushion
spear that can be provided in the standard envelope without
decreasing the rod bearing and piston bearing strengths.

In the cushion performance chart, pressure traces show the


results of typical orifice flow conditions. Tests of a three-step
sleeve or spear show three pressure pulses coinciding with the


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Features and Benefits


Adjustable Floating Stepped Cushions For
maximum performance economical and flexible
for even the most demanding applications
provides superior performance in reducing shock.
Cushions are optional and can be supplied at head
end, cap end, or both ends without change
in envelope or mounting dimensions.

Steel Cap Bored


and grooved to provide
concentricity for
mating parts.

Optional High Temperature


Gland Dual filled PTFE rod
seals and filled PTFE wiper seal
are energized with fluorocarbon
o-rings to maintain consistent
contact with the piston rod.
Excellent sealing performance
produce dry rod on extend
stroke with rod scraping to clean
rod on retract. Combine with Spring Loaded PTFE
Piston Seals for cylinder heat resistance to 400 F.
See class 8 seal specification on Operating Fluids and
Temperature Range page.

Optional
Pistons
OPTIONAL PISTONS

Hi Load Piston Optional at


extra charge. Includes wear
rings and bronze-filled PTFE
seals. Two wear rings serve as
bearings which deform radially
under side-loading, enabling the
load to be spread over a larger
area and reduce unit loading.
SYNTHETIC RUBBER
EXPANDER RINGS
Bronze-filled PTFE seals are
designed for extrusion-free, leak-proof service and
longer cylinder life than the lipseal type piston.
PHENOLIC
BEARINGS

Cylinder Body
Heavy-wall steel
tubing, honed to
a micro finish bore.

Align-A-Groove (Patent #3043639)


A 3/16" wide surface machined at each end of
the cylinder body. Makes precise mounting
quick and easy.
Lipseal Piston Zero leakage under static
conditions for hydraulic pressures up to
3000 PSI. Seals are self-compensating to
conform to variations in pressure, mechanical
deflection, and wear. Back-up washer
prevents extrusion.

One-Piece Nodular Iron Piston The


wide piston surface contacting cylinder
bore reduces bearing loads. Anaerobic
adhesive is used to permanently lock and
seal the piston to the rod.

Step cut iron piston rings


are optional at no extra
charge.

BRONZE
FILLED PTFE
TEFLON RINGS

Spring Loaded PTFE


Piston Seals
Optional filled PTFE piston
Lipseals utilize an internal
stainless steel spring to
energize both the dynamic and static sealing lips to
optimize seal performance throughout the operating
temperature range. Non-metallic piston wear ring
in 1.50"-6.00" bores (bronze in 7.00" & 8.00" bore
3H) reduces possibility of damaging piston which
can score expensive tubing. Combine with High
Temperature Gland for cylinder heat resistance to
400 F. See class 8 seal specification on Operating
Fluids and Temperature Range page.

e. 1.50" - 2.50" bore cylinders use a cartridge style needle


valve (see Figure A).

(1) When a cushion is specified at the head end:


a. A self-centering stepped sleeve is furnished on the
piston rod assembly.

(2) When a cushion is specified at the cap end:


a. A stepped cushion spear is provided on the piston rod.
b. A float check self-centering bushing is provided which
incorporates a large flow check valve for fast
out-stroke action.
c. A socket-keyed needle valve is provided that is flush
with the side of the cap when wide open. It is located
on side number 2 in all mounting styles except D, DB,
DD, DE, JJ, and HH. In these styles it is located on side
number 3.

b. A needle valve is provided that is flush with the side of


the head even when wide open. It may be identified by
the fact that it is socket-keyed. It is located on side
number 2, in all mounting styles except D, DB, DD, DE,
JJ, and HH. In these styles it is located on side number 3.
c. On 6.00" bore and larger cylinders a springless check
valve is provided that is also flush with the side of the
head and is mounted adjacent to the needle valve except
on mounting style C, where it is mounted opposite the
needle valve. It may be identified by the fact that it is
slotted.
d. On 1.50" - 5.00" bore cylinders a slotted sleeve design is
used in place of the check valve.

STEPPED CUSHIONS
ROD END SLEEVE

CAP END SPEAR

Figure A


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Application Checklist

Heavy Duty Hydraulic Cylinders


Series 2H

Application Checklist

The following checklist should used to select the best possible cylinder for a given application. Additional information
can be referenced in the following pages to help assist in this process. In the event that you have additional
questions or concerns, or if more information is required, please contact your local Parker distributor or our
customer service representatives for assistance.
1.




Establish the system requirements......................................................................................................... Series 2H


How heavy is the load to be moved?
What is the nominal operating pressure of the system?
How far does the load have to move?
What is the speed at which the load will move?
What is the fluid type and the temperature to which the cylinder will be exposed?

2. Mounting Style........................................................................................................................................... Page 7


Determine the best mounting style for the application.

3. Cylinder Bore and Operating Pressure.................................................................................................... Page 96


Review the theoretical push and pull force for a given bore size to determine.

4. Piston Rod................................................................................................................................................... Page 104






5.


Determine what rod size will be required to avoid buckling.


Determine if a single or double rod cylinder is required.
Determine the rod end style and rod end thread.
Will stop tubing be required?

Piston Seals................................................................................................................................................ Page 99


Determine the best seal type for your application.
Select the proper seal type and configuration for the application.
Select the proper seal to assure fluid and temperature compatibility.

6. Cushioning................................................................................................................................................. Page 106


Determine if cushions are required to safely stop the load.

7. Ports............................................................................................................................................................ Page 101


Select the best possible port size for a given speed requirement.
Select port position.
8. Piston rod and mounting accessories.................................................................................................... Page 66
Determine how you will attach the cylinder to the load.
9. Optional accessories and modifications................................................................................................ Page 65


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Style Tips

Mounting Styles & Tips for Applying Them


Extended Tie Rod Mountings TB, TC, and TD
Application:
Straight line force transfer
Compression loads (push)
use TC or TD
Tension loads (pull)
use TB or TD

Advantages:
Ease of mounting in tight spaces
Force is transferred along the
centerline of the cylinder

Flange Mountings J, JB, JJ, H, HB, and HH


Application:
Straight line force transfer
Compression loads (push)
use H, HB or HH
Tension loads (pull)
use J, JB, or JJ

Advantages:
Rigid base mounting due to
large flange area
Force is transferred along the
centerline of the cylinder

Side Tap Mounting F / Side Lug Mounting C


Application:
Straight line force transfer
Can be used in compression
or tension loads
Thrust key and secure
mounting area are vital

Advantages:
Ease of mounting

Pivot Mountings BB and SB


Application:
Curved or arc line force
transfer
Can be used in compression or
tension loads
Movement in a simple arc
use BB mountings
Movement in a compound arc
use SB mountings

Advantages:
Ease of mounting
Design flexibility
Self aligning (SB)

Trunnion Mountings D, DB, DD and DE


Application:
Curved or arc line force
transfer
Can be used in compression or
tension loads
Compression loads use DB
or DD, DE mountings
Tension loads use D, DD or
DE mountings

Advantages:
Ease of mounting
Design flexibility
Self aligning


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

How To Order

2H Model Code
5.00

TB

2H

Bore Dia.

Cushion
Head

Double
Rod End
Cylinder

Mounting
Style

Mounting
Modification

Combination
Mounts 4

Series
Designator

Piston Seal

Ports

Specify
bore dia.
in inches
1.50
2.00
2.50
3.25
4.00
5.00
6.00

Use C
only if head
end cushion
is required.

Use K only
if a double
rod end
cylinder is
required.1

P = Use only if
Thrust Key
required.
(Style C or F.)
M = Use only for
Manifold Port
O-Ring Seal.
Applies to C
Mount only.

Any practical
mounting
style listed.

T = Basic, No Mount
TB = Tie Rods Ext. Head
TC = Tie Rods Ext. Cap
TD = Tie Rods Ext. Both Ends
J = Head Rectangular Flange
JB = Head Square Flange
JJ = Head Rectangular
H = Cap Rectangular Flange
HB = Cap Square Flange
HH = Cap Rectangular
C = Side Lug 2
F = Side Tapped 2
BB = Cap Fixed Clevis
D = Head Trunnion
DB = Cap Trunnion
DD = Int. Fixed Trunnion 3
DE = Heavy Duty Intermediate
Fixed Trunnion3
SB = Spherical Bearing

2H
2HD
C = Ring Packed Piston
(std.)
L = Lip Seal Piston
K = Hi Load Piston
F = Low Friction
S = Spring Loaded
PTFE piston seals
3 = Magnetic Piston,
stainless steel
cylinder body, single
bi-directional piston
seal
7 = Magnetic Piston,
carbon steel body,
single bi-directional
piston seal

T = SAE Straight Thread O-Ring (Std.)


U = NPTF Ports (Dry Seal Pipe Thread)
R = BSP Ports (Parallel Thread ISO 228)
P = SAE Flange Ports (3,000 psi)
B = BSPT Ports (Taper Thread)
G = Metric Thread Ports
Y = Metric Thread Ports per ISO 6149
M = Used only for Manifold Port O-ring
Seal. M option must be specified
(Mounting Modification), applies to
Mounting Style C only.

Shaded boxes identify required model number fields.


Available mounting styles for K Type cylinders are located at the end of Section A.
When ordering a double rod end cylinder, the piston rod number and piston rod end
threads are to be specified for both rod ends.
The model number should be created as viewing the primary rod end on the left
hand side.
Example: K Type Cylinder:
4.00CKTD2HLT14A28AC10.000
2
Mounting Styles C and F should have a minimum stroke length equal to or greater than
their bore size.
3
Specify XI dimension.
4
In general, the model numbers as read left to right corresponding to the cylinder as
viewed from left to right with the primary end at the left. The second or subsequent
mountings are mountings called out as they appear in the assembly moving away from
the rod end. Except when tie rod extension mountings are part of a combination, all
combinations should have a S (Special) in the model code and a note in the body of the
order clarifying the mounting arrangement. The P, as used to define a thrust key is not
considered to be a mounting. However it is located at the primary end.
1


www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

How To Order

2H Model Code
J

16.000

Common
Modification 5

Special
Modification

Piston Rod
Number 8

Piston Rod
End

Piston Rod
Threads

Cushion Cap

Stroke7

A
Use only if special
modifications are
required:
Oversize Ports
Port Position Change
Special Seals
Stop Tube 7
Stroke Adjusters
Tie Rod Supports
Other
J = High Water Content Fluid
V = Fluorocarbon Seals
W = Water Service
X = EPR Seals
2 = Class 2 Seals
4 = Class 4 Seals
E = Fluorocarbon Seals
Piston Rod only
H = Class 8 Seals
N = High Temperature
Rod Gland 6

1
2
3
4

Used only
if cushion
required

Style 4 Small Male


Style 7 Female Thread for
Spherical Rod Eye for
Piston Rod Codes Larger
than Code #1
Style 8 Intermediate Male
Style 9 Short Female 9
Style 55 Rod End for Flange
Coupling
Style 3 Special (Specify) 10

Specify
in inches

A = UNF Standard
M = Metric11

Style 9 Minimum Stroke Table

Shaded boxes identify required model number fields.


See common modifications Section D for additional options.
6
Energized PTFE rod seals & wiperseal. All other cylinder seals are
fluorocarbon.
7
S = Stop Tube. Specify: stop tube length, net stroke and gross stroke.
Gross stroke = stop tube length + net stroke. Gross stroke to be placed in the
model number field.
Example:

2.000 inches long stop tube
+14.000 inches net stroke

16.000 inches gross stroke
8
Refer to Rod buckling chart in Section E to assure rod number selected
will not buckle under load.
9
Style 9 stroke restrictions may apply. See Style 9 Minimum Stroke
Table for details.
10
Provide dimensions for KK, A, W or WF. If otherwise special,
furnish dimensioned sketch.
11
See Section D for detailed information regarding standard metric rod end
thread sizes.
5


www.parker.com/cylinder

Bore

Rod

Minimum
Stroke

1.50 - 4.00
5.00

All
2.000
2.500
3.000
3.500
2.500
3.000
3.500
4.000

None
None
1.000
1.375
1.625
None
1.375
1.375
2.000

6.00

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Piston Rod Ends

Rod End Dimensions


Thread Style 4 (NFPA Style SM)
Small Male
W

Thread Style 8 (NFPA Style IM)


Intermediate Male

WF
V

KK

WF
V

CC

MM

D WRENCH
FLATS

MM

D WRENCH
FLATS

NA

NA

Rod End Dimensions


Bore

1.50
2.00

2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

Style 8
CC

Style 4
KK

1 (Std.)

0.625

1/2-20

7/16-20

0.75

Thread

NA

WF

1.124

0.50

0.38

0.56

0.25

0.63

1.00

+.000
-.002

1.000

7/8-14

3/4-16

1.13

1.499

0.88

0.38

0.94

0.50

1.00

1.38

1 (Std.)

1.000

7/8-14

3/4-16

1.13

1.499

0.88

0.63

0.94

0.25

0.75

1.38

1.375

1 1/4-12

1-14

1.63

1.999

1.13

0.63

1.31

0.38

1.00

1.63

1 (Std.)

1.000

7/8-14

3/4-16

1.13

1.499

0.88

0.63

0.94

0.25

0.75

1.38

1.750

1 1/2-12 1 1/4-12

2.00

2.374

1.50

0.63

1.69

0.50

1.25

1.88

1.375

1 1/4-12

1-14

1.63

1.999

1.13

0.63

1.31

0.38

1.00

1.63

1-14

1 (Std.)

1.375

1 1/4-12

1.63

1.999

1.13

0.75

1.31

0.25

0.88

1.63

2.000

1 3/4-12 1 1/2-12

2.25

2.624

1.69

0.75

1.94

0.38

1.25

2.00

1.750

1 1/2-12 1 1/4-12

2.00

2.374

1.50

0.75

1.69

0.38

1.13

1.88

1 (Std.)

1.750

1 1/2-12 1 1/4-12

2.00

2.374

1.50

0.88

1.69

0.25

1.00

1.88

2.500

2 1/4-12 1 7/8-12

3.00

3.124

2.06

0.88

2.38

0.38

1.38

2.25

2.000

1 3/4-12 1 1/2-12

2.25

2.624

1.69

0.88

1.94

0.25

1.13

2.00

1 (Std.)

2.000

1 3/4-12 1 1/2-12

2.25

2.624

1.69

0.88

1.94

0.25

1.13

2.00

3.500

3 1/4-12 2 1/2-12

3.50

4.249

3.00

0.88

3.38

0.38

1.38

2.25

2.500

2 1/4-12 1 7/8-12

3.00

3.124

2.06

0.88

2.38

0.38

1.38

2.25

3.000

2 3/4-12 2 1/4-12

3.50

3.749

2.63

0.88

2.88

0.38

1.38

2.25

1 (Std.)

2.500

2 1/4-12 1 7/8-12

3.00

3.124

2.06

1.00

2.38

0.25

1.25

2.25

4.000

3 3/4-12

4.00

4.749

3.38

1.00

3.88

0.25

1.25

2.25

3.000

2 3/4-12 2 1/4-12

3-12

3.50

3.749

2.63

1.00

2.88

0.25

1.25

2.25

3.500

3 1/4-12 2 1/2-12

3.50

4.249

3.00

1.00

3.38

0.25

1.25

2.25

Special Thread Style 3


Special thread, extension, rod eye, blank, etc., are also available.
To order, specify Style 3 and give desired dimensions for KK, A, W or WF.
If otherwise special, furnish dimensioned sketch.

10
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Piston Rod Ends

Rod End Dimensions


Thread Style 9 2
(NFPA Style SF) Small Female
W

Style 551
Flanged Rod End

WF
A

WG

.06R

KK

D WRENCH
FLATS

MM

B AM

MM

AF
NA

AE
F

AD

Rod End Dimensions


Bore

1.50
2.00

2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

Thread

1 (Std.)

0.625

7/16-20

0.75

0.63 0.249 0.38

Style 9
KK

AD

AE
+.001
-.001

AF

AM

B
+.000
-.002

NA

WF

WG

0.57 1.124 0.50

0.38

0.56

0.25

0.63

1.00

1.75

1.000

3/4-16

1.13

0.94 0.374 0.69

0.95 1.499 0.88

0.38

0.94

0.50

1.00

1.38

2.38

1 (Std.)

1.000

3/4-16

1.13

0.94 0.374 0.69

0.95 1.499 0.88

0.63

0.94

0.25

0.75

1.38

2.38

1.375

1-14

1.63

1.06 0.374 0.88

1.32 1.999 1.13

0.63

1.31

0.38

1.00

1.63

2.75

1 (Std.)

1.000

3/4-16

1.13

0.94 0.374 0.69

0.95 1.499 0.88

0.63

0.94

0.25

0.75

1.38

2.38

1.750

1 1/4-12

2.00

1.31 0.499 1.13

1.70 2.374 1.50

0.63

1.69

0.50

1.25

1.88

3.13

1.375

1-14

1.63

1.06 0.374 0.88

1.32 1.999 1.13

0.63

1.31

0.38

1.00

1.63

2.75

1 (Std.)

1.375

1-14

1.63

1.06 0.374 0.88

1.32 1.999 1.13

0.75

1.31

0.25

0.88

1.63

2.75

2.000

1 1/2-12

2.25

1.69 0.624 1.38

1.95 2.624 1.69

0.75

1.94

0.38

1.25

2.00

3.75

1.750

1 1/4-12

2.00

1.31 0.499 1.13

1.70 2.374 1.50

0.75

1.69

0.38

1.13

1.88

3.13

1 (Std.)

1.750

1 1/4-12

2.00

1.31 0.499 1.13

1.70 2.374 1.50

0.88

1.69

0.25

1.00

1.88

3.13

2.500

1 7/8-12

3.00

1.94 0.749 1.75

2.45 3.124 2.06

0.88

2.38

0.38

1.38

2.25

4.50

2.000

1 1/2-12

2.25

1.69 0.624 1.38

1.95 2.624 1.69

0.88

1.94

0.25

1.13

2.00

3.75

1 (Std.)

2.000

1 1/2-12

2.25

1.69 0.624 1.38

1.95 2.624 1.69

0.88

1.94

0.25

1.13

2.00

3.75

3.500

2 1/2-12

3.50

2.69 0.999 2.50

3.45 4.249 3.00

0.88

3.38

0.38

1.38

2.25

5.63

2.500

1 7/8-12

3.00

1.94 0.749 1.75

2.45 3.124 2.06

0.88

2.38

0.38

1.38

2.25

4.50

3.000

2 1/4-12

3.50

2.44 0.874 2.25

2.95 3.749 2.63

0.88

2.88

0.38

1.38

2.25

4.88

1 (Std.)

2.500

1 7/8-12

3.00

1.94 0.749 1.75

2.45 3.124 2.06

1.00

2.38

0.25

1.25

2.25

4.50

4.000

3-12

4.00

2.69 0.999 3.00

3.95 4.749 3.38

1.00

3.88

0.25

1.25

2.25

5.75

3.000

2 1/4-12

3.50

2.44 0.874 2.25

2.95 3.749 2.63

1.00

2.88

0.25

1.25

2.25

4.88

3.500

2 1/2-12

3.50

2.69 0.999 2.50

3.45 4.249 3.00

1.00

3.38

0.25

1.25

2.25

5.63

Special Thread Style 3


Special thread, extension, rod eye, blank, etc., are also available.
To order, specify Style 3 and give desired dimensions for KK, A, W or WF.
If otherwise special, furnish dimensioned sketch.
For special WG dimension, specify Style 3 and give desired dimension for WG. For
other changes, place S in the model code, and describe rod end with dimensioned sketch.
2
Style 9 stroke restrictions may apply. See Style 9 Minimum Stroke Table on How to Order page
for details.
1

11
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Tie Rods Extended Both Ends Mounting
Style TD
(NFPA Style MX1)

ZJ + STROKE
LB + STROKE
P + STROKE
EE

Y
W

AA

E 4
SQ.

MM

DD

3
R
SQ.

BB

BB

Table 1 Dimensional and Mounting Data


Bore

1.50
2.00

Rod
No.

MM
Rod

AA

1 (std.)

0.625

2.31

1.38 3/8-24 2.50

1/2

10

0.38

1.75

1.50

0.38

1.63

0.63

1.000

2.31

1.38 3/8-24 2.50

1/2

10

0.38

1.75

1.50

0.38

1.63

1.00

1 (std.)

1.000

2.90

1.81 1/2-20 3.00

1/2

10

0.63

1.75

1.50

0.44

2.05

0.75

2.38

5.25

2.88

6.00

1.375

2.90

1.81 1/2-20 3.00

1/2

10

0.63

1.75

1.50

0.44

2.05

1.00

2.63

5.25

2.88

6.25

1 (std.)

1.000

3.61

1.81 1/2-20 3.50

1/2

10

0.63

1.75

1.50

0.44

2.55

0.75

2.38

5.38

3.00

6.13

1.750

3.61

1.81 1/2-20 3.50

1/2

10

0.63

1.75

1.50

0.44

2.55

1.25

2.88

5.38

3.00

6.63

1.375

3.61

1.81 1/2-20 3.50

1/2

10

0.63

1.75

1.50

0.44

2.55

1.00

2.63

5.38

3.00

6.38

1 (std.)

1.375

4.60

2.31 5/8-18 4.50

3/4

12

0.75

2.00

1.75

0.56

3.25

0.88

2.75

6.25

3.50

7.13

2.000

4.60

2.31 5/8-18 4.50

3/4

12

0.75

2.00

1.75

0.56

3.25

1.25

3.13

6.25

3.50

7.50

2.50

3.25

BB

DD

EE

NPTF1 SAE2

Add Stroke
LB

ZJ

2.00

5.00

2.88

5.63

2.38

5.00

2.88

6.00

1.750

4.60

2.31 5/8-18 4.50

3/4

12

0.75

2.00

1.75

0.56

3.25

1.13

3.00

6.25

3.50

7.38

1 (std.)

1.750

5.40

2.31 5/8-18 5.00

3/4

12

0.88

2.00

1.75

0.56

3.82

1.00

3.00

6.63

3.75

7.63

2.500

5.40

2.31 5/8-18 5.00

3/4

12

0.88

2.00

1.75

0.56

3.82

1.38

3.38

6.63

3.75

8.00

4.00

2.000

5.40

2.31 5/8-18 5.00

3/4

12

0.88

2.00

1.75

0.56

3.82

1.13

3.13

6.63

3.75

7.75

1 (std.)

2.000

7.00

3.19 7/8-14 6.50

3/4

12

0.88

2.00

1.75

0.81

4.95

1.13

3.13

7.13

4.25

8.25

3.500

7.00

3.19 7/8-14 6.50

3/4

12

0.88

2.00

1.75

0.81

4.95

1.38

3.38

7.13

4.25

8.50

2.500

7.00

3.19 7/8-14 6.50

3/4

12

0.88

2.00

1.75

0.81

4.95

1.38

3.38

7.13

4.25

8.50

3.000

7.00

3.19 7/8-14 6.50

3/4

12

0.88

2.00

1.75

0.81

4.95

1.38

3.38

7.13

4.25

8.50

1 (std.)

2.500

8.10

3.63

1-14

7.50

16

1.00

2.25

2.25

0.88

5.73

1.25

3.50

8.38

4.88

9.63

4.000

8.10

3.63

1-14

7.50

16

1.00

2.25

2.25

0.88

5.73

1.25

3.50

8.38

4.88

9.63

3.000

8.10

3.63

1-14

7.50

16

1.00

2.25

2.25

0.88

5.73

1.25

3.50

8.38

4.88

9.63

3.500

8.10

3.63

1-14

7.50

16

1.00

2.25

2.25

0.88

5.73

1.25

3.50

8.38

4.88

9.63

5.00

6.00

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
1

Style T

Style TB

Style TC

Dimensions for T, TB and TC Mount may be obtained from the above dimensional table.
12
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Head Rectangular Flange Mounting
Style J
(NFPA Style MF1)

W
UF
1

E R4

3
E
TF

ZB + STROKE
LB + STROKE
P + STROKE
EE

MM

FB (X4)

A
F
WF

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE

NPTF1

SAE2

1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

0.38
0.63
0.63
0.75
0.88
0.88
1.00

FB

0.44
0.56
0.56
0.69
0.69
0.94
1.06

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

R
1.63
2.05
2.55
3.25
3.82
4.95
5.73

TF
3.44
4.13
4.63
5.88
6.38
8.19
9.44

UF
4.25
5.13
5.63
7.13
7.63
9.75
11.25

Add Stroke
LB

5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

WF

Table 3 Maximum Operating Pressure - 2H


Y

Add Stroke

Bore

ZB Max.
1.00
1.38
1.38
1.63
1.38
1.88
1.63
1.63
2.00
1.88
1.88
2.25
2.00
2.00
2.25
2.25
2.25
2.25
2.25
2.25
2.25

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

1.50
2.00
2.50
3.25
4.00
5.00
6.00

Maximum psi Push3


Rod Code
1
1500
2000
2000
1800
1800
1300
1200

2
1000
1200
1100
1300
1300
800
800

3
1500
1400
1700
1200
1000

4
1000
900

Table 4 Maximum Operating Pressure - 2HD


Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00
3

Maximum psi Push3


Rod Code
1
1400
2000
700
800
1000
850
650

2
1000
1200
1000
600
700
800
400

3
700
800
1000
850
650

4
450
400

Maximum Pressure Rating Push Application.

13
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


TF
R
1

Head Square Flange Mounting


Style JB
(NFPA Style MF5)

ZB + STROKE
LB + STROKE
P + STROKE

EE

TF R 4

MM

J
3
E SQ.
UF SQ.

F
WF

FB (X8)

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE
NPTF
1/2
1/2
1/2
3/4
3/4
3/4
1

SAE
10
10
10
12
12
12
16

FB

TF

UF

0.38
0.63
0.63
0.75
0.88
0.88
1.00

0.44
0.56
0.56
0.69
0.69
0.94
1.06

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

1.63
2.05
2.55
3.25
3.82
4.95
5.73

3.44
4.13
4.63
5.88
6.38
8.19
9.44

4.25
5.13
5.63
7.13
7.63
9.75
11.25

Add Stroke
LB
5.00
5.25
5.38
6.25
6.63
7.13
8.38

P
2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

WF

Table 3 Maximum Operating Pressure - 2H


Y

Add Stroke

Bore

ZB Max.
1.00
1.38
1.38
1.63
1.38
1.88
1.63
1.63
2.00
1.88
1.88
2.25
2.00
2.00
2.25
2.25
2.25
2.25
2.25
2.25
2.25

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

1.50
2.00
2.50
3.25
4.00
5.00
6.00
3

Maximum psi Push3


Rod Code
1

3000
3000
3000
3000
3000
3000
3000

3000
3000
3000
3000
3000
3000
2700

3000
3000
3000
3000
3000

3000
2700

Maximum Pressure Rating Push Application.

Table 4 Maximum Operating Pressure - 2HD

14
www.parker.com/cylinder

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

Maximum psi Push3


Rod Code
1

3000
3000
3000
3000
3000
2500
2000

3000
3000
3000
3000
3000
2300
1600

3000
3000
3000
2500
2000

1800
1600

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Head Rectangular Mounting
Style JJ
(NFPA Style ME5)

ZB + STROKE
P + STROKE
LG + STROKE
EE

Y
WF
KB

UF
1

ER4

2 RD MM

3
E
TF

FB (X4)

RT
G

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

SAE2

FB

NPTF1

EE
1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

0.44
0.56
0.56
0.69
0.69
0.94
1.06

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

R
1.63
2.05
2.55
3.25
3.82
4.95
5.73

TF
3.44
4.13
4.63
5.88
6.38
8.19
9.44

UF
4.25
5.13
5.63
7.13
7.63
9.75
11.25

Add Stroke
LG

4.63
4.63
4.75
5.50
5.75
6.25
7.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

B
+.000
-.002

KB

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

1.124
1.499
1.499
1.999
1.499
2.374
1.999
1.999
2.624
2.374
2.374
3.124
2.624
2.624
4.249
3.124
3.749
3.124
4.749
3.749
4.249

.25
.25
.25
.25
.13
.25
.25
.25
.13
.13
.25
.25
.25
.25
.25
.25
.25

RD

RT

2.13
2.50
2.50
3.00
2.50
3.50
3.00
3.00
4.00
3.50
3.50
4.50
4.00
4.00
5.75
4.50
5.25
4.50
6.50
5.25
5.75

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.63
0.38
0.38
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.75
0.63
0.63

WF

Add Stroke
ZB Max

0.25
0.50
0.50
0.63
0.50
0.75
0.63
0.63
0.50
0.75
0.75
0.63
0.50
0.50
0.63
0.63
0.63
0.63
0.50
0.63
0.63

1.00
1.38
1.38
1.63
1.38
1.88
1.63
1.63
2.00
1.88
1.88
2.25
2.00
2.00
2.25
2.25
2.25
2.25
2.25
2.25
2.25

15
www.parker.com/cylinder

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Cap Rectangular Flange Mounting
Style H
(NFPA Style MF2)

ZF + STROKE
XF + STROKE
P + STROKE
LB + STROKE
EE

Heavy Duty Hydraulic Cylinders


Series 2H

UF
1

4 R E

MM

3
E
TF

FB (X4)

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE
NPTF1
SAE2
1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

FB

TF

UF

0.38
0.63
0.63
0.75
0.88
0.88
1.00

0.44
0.56
0.56
0.69
0.69
0.94
1.06

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

1.63
2.05
2.55
3.25
3.82
4.95
5.73

3.44
4.13
4.63
5.88
6.38
8.19
9.44

4.25
5.13
5.63
7.13
7.63
9.75
11.25

Add Stroke
LB
P
5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

Y
2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

Table 3 Maximum Operating Pressure 2H & 2HD

Add Stroke
XF

ZF

5.63
6.00
6.00
6.25
6.13
6.63
6.38
7.13
7.50
7.38
7.63
8.00
7.75
8.25
8.50
8.50
8.50
9.63
9.63
9.63
9.63

6.00
6.38
6.63
6.88
6.75
7.25
7.00
7.88
8.25
8.13
8.50
8.88
8.63
9.13
9.38
9.38
9.38
10.63
10.63
10.63
10.63

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00
3

1
2500
3000
3000
3000
3000
2000
1800

Maximum psi Pull3


Rod Code
2
3
3000
3000
3000
3000
3000
3000
3000
3000
3000
2000
2500
2000

4
2500
2000

Maximum pressure rating pull application.

16
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Cap Square Flange Mounting
Style HB
(NFPA Style MF6)

Heavy Duty Hydraulic Cylinders


Series 2H

ZF + STROKE
XF + STROKE
P + STROKE
LB + STROKE
EE

TF
R
1

4 R TF

MM

A
F

G
J

3
E SQ.
UF SQ.

FB (X8)

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE
NPTF1
SAE2
1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

FB

TF

UF

0.38
0.63
0.63
0.75
0.88
0.88
1.00

0.44
0.56
0.56
0.69
0.69
0.94
1.06

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

1.63
2.05
2.55
3.25
3.82
4.95
5.73

3.44
4.13
4.63
5.88
6.38
8.19
9.44

4.25
5.13
5.63
7.13
7.63
9.75
11.25

Add Stroke
LB
P
5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

Y
2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

Add Stroke
XF

ZF

5.63
6.00
6.00
6.25
6.13
6.63
6.38
7.13
7.50
7.38
7.63
8.00
7.75
8.25
8.50
8.50
8.50
9.63
9.63
9.63
9.63

6.00
6.38
6.63
6.88
6.75
7.25
7.00
7.88
8.25
8.13
8.50
8.88
8.63
9.13
9.38
9.38
9.38
10.63
10.63
10.63
10.63

17
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Cap Rectangular Flange Mounting
Style HH
(NFPA Style ME6)

XF + STROKE
P + STROKE
LB + STROKE
EE

Heavy Duty Hydraulic Cylinders


Series 2H

UF
1

4R E

MM

3
E
TF

FB
(X4)

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE
NPTF1
SAE2
1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

FB

TF

UF

0.38
0.63
0.63
0.75
0.88
0.88
1.00

0.44
0.56
0.56
0.69
0.69
0.94
1.06

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

1.63
2.05
2.55
3.25
3.82
4.95
5.73

3.44
4.13
4.63
5.88
6.38
8.19
9.44

4.25
5.13
5.63
7.13
7.63
9.75
11.25

Add Stroke
LB
P
5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

Add Stroke
XF

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

5.63
6.00
6.00
6.25
6.13
6.63
6.38
7.13
7.50
7.38
7.63
8.00
7.75
8.25
8.50
8.50
8.50
9.63
9.63
9.63
9.63

18
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Side Lug Mounting
Style C
(NFPA Style MS2)

US
1

ZB + STROKE
P + STROKE
LB + STROKE
EE

MM

E -.005
2 -.010 ST
3
E SQ.
TS

SW
SW

SB (X4)
SW
SW

F
SW
XS

J
SU

K
SW

SU
SS + STROKE

Table 1 Dimensional and Mounting Data


Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE

NPTF1 SAE2
1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

0.38
0.63
0.63
0.75
0.88
0.88
1.00

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

SB3

ST

0.44
0.56
0.81
0.81
1.06
1.06
1.31

0.50
0.75
1.00
1.00
1.25
1.25
1.50

SU
0.94
1.25
1.56
1.56
2.00
2.00
2.50

SW
0.38
0.50
0.69
0.69
0.88
0.88
1.13

TS
3.25
4.00
4.88
5.88
6.75
8.25
9.75

US
4.00
5.00
6.25
7.25
8.50
10.00
12.00

Add Stroke
LB

SS

5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

3.88
3.63
3.38
4.13
4.00
4.50
5.13

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.
3
Upper surface spot faced for socket head screws.
1
2

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

XS

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

1.38
1.75
1.88
2.13
2.06
2.56
2.31
2.31
2.69
2.56
2.75
3.13
2.88
2.88
3.13
3.13
3.13
3.38
3.38
3.38
3.38

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

Add Stroke
ZB Max.
6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

19
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Side Tapped Mounting
Style F
(NFPA Style MS4)

ZB + STROKE
P + STROKE
LB + STROKE

Y
W

EE

E 4
SQ

2
E -.005
2 -.010
3
TN

EE
NPTF1 SAE2

F
XT

NT THREAD,
ND DEEP (X4)

Table 1 Dimensional and Mounting Data


Bore

MM

ND

NT

J
SN + STROKE

TN
LB

Add Stroke
P
SN

1.50

2.50

1/2

10

0.38

1.75

1.50

0.38

0.38

3/8-16

0.75

5.00

2.88

2.88

2.00

3.00

1/2

10

0.63

1.75

1.50

0.44

0.44

1/2-13

0.94

5.25

2.88

2.88

2.50

3.50

1/2

10

0.63

1.75

1.50

0.44

0.50

5/8-11

1.31

5.38

3.00

3.00

3.25

4.50

3/4

12

0.75

2.00

1.75

0.56

0.69

3/4-10

1.50

6.25

3.50

3.50

4.00

5.00

3/4

12

0.88

2.00

1.75

0.56

0.69

1-8

2.06

6.63

3.75

3.75

5.00

6.50

3/4

12

0.88

2.00

1.75

0.81

1.00

1-8

2.94

7.13

4.25

4.25

6.00

7.50

16

1.00

2.25

2.25

0.88

1.25

1 1/4 -7

3.31

8.38

4.88

5.13

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
1

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00

2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

XT

Add Stroke
ZB Max.

1 (std.)

0.625

0.63

2.00

2.00

6.25

1.000

1.00

2.38

2.38

6.63

1 (std.)

1.000

0.75

2.38

2.38

6.69

1.375

1.00

2.63

2.63

6.94

1 (std.)

1.000

0.75

2.38

2.38

6.81

1.750

1.25

2.88

2.88

7.31

1.375

1.00

2.63

2.63

7.06

1 (std.)

1.375

0.88

2.75

2.75

7.94

2.000

1.25

3.13

3.13

8.31
8.19

1.750

1.13

3.00

3.00

1 (std.)

1.750

1.00

3.00

3.00

8.50

2.500

1.38

3.38

3.38

8.88

2.000

1.13

3.13

3.13

8.63

1 (std.)

2.000

1.13

3.13

3.13

9.38

3.500

1.38

3.38

3.38

9.63

2.500

1.38

3.38

3.38

9.63

3.000

1.38

3.38

3.38

9.63

1 (std.)

2.500

1.25

3.50

3.50

10.81

4.000

1.25

3.50

3.50

10.81

3.000

1.25

3.50

3.50

10.81

3.500

1.25

3.50

3.50

10.81

20
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Cap Fixed Clevis Mounting
Style BB
(NFPA Style MP1)

ZC + STROKE
XC + STROKE
P + STROKE
LB + STROKE
EE

CD

PIVOT
PIN
MM

E
4 SQ

2
MR
K

LR
F

3
CB

CW

CW

Table 1 Dimensional and Mounting Data


Bore

EE
NPTF

SAE

CB

CD3
+.000
-.002

CW

LR

MR

Add Stroke
LB
P

1.50

2.50

1/2

10

0.75

.501

0.50

0.38

1.75

1.50

0.38

0.75

0.56

0.63

5.00

2.88

2.00

3.00

1/2

10

1.25

.751

0.63

0.63

1.75

1.50

0.44

1.25

1.00

0.94

5.25

2.88

2.50

3.50

1/2

10

1.25

.751

0.63

0.63

1.75

1.50

0.44

1.25

0.94

0.94

5.38

3.00

3.25

4.50

3/4

12

1.50

1.001

0.75

0.75

2.00

1.75

0.56

1.50

1.25

1.19

6.25

3.50

4.00

5.00

3/4

12

2.00

1.376

1.00

0.88

2.00

1.75

0.56

2.13

1.75

1.63

6.63

3.75

5.00

6.50

3/4

12

2.50

1.751

1.25

0.88

2.00

1.75

0.81

2.25

2.06

2.13

7.13

4.25

6.00

7.50

16

2.50

2.001

1.25

1.00

2.25

2.25

0.88

2.50

2.31

2.38

8.38

4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.
3
Diameter CD is Pin Diameter.
1
2

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00

2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

Add Stroke
XC
ZC

1 (std.)

0.625

0.63

2.00

6.38

6.88

1.000

1.00

2.38

6.75

7.25

1 (std.)

1.000

0.75

2.38

7.25

8.00

1.375

1.00

2.63

7.50

8.25

1 (std.)

1.000

0.75

2.38

7.38

8.13

1.750

1.25

2.88

7.88

8.63

1.375

1.00

2.63

7.63

8.38

1 (std.)

1.375

0.88

2.75

8.63

9.63
10.00

2.000

1.25

3.13

9.00

1.750

1.13

3.00

8.88

9.88

1 (std.)

1.750

1.00

3.00

9.75

11.13

2.500

1.38

3.38

10.13

11.50
11.25

2.000

1.13

3.13

9.88

1 (std.)

2.000

1.13

3.13

10.50

12.25

3.500

1.38

3.38

10.75

12.50

2.500

1.38

3.38

10.75

12.50

3.000

1.38

3.38

10.75

12.50

1 (std.)

2.500

1.25

3.50

12.13

14.13

4.000

1.25

3.50

12.13

14.13

3.000

1.25

3.50

12.13

14.13

3.500

1.25

3.50

12.13

14.13

21
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Head Trunnion Mounting
Style D
(NFPA Style MT1)

Heavy Duty Hydraulic Cylinders


Series 2H

ZB + STROKE
P + STROKE
LB + STROKE
EE

UT
1
.125R MAX.
E
SQ.TD 4

2 MM

TL

TL

XG

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE

NPTF1

SAE2

1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

0.38
0.63
0.63
0.75
0.88
0.88
1.00

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

TD
+.000
-.001

TL

1.000
1.375
1.375
1.750
1.750
1.750
2.000

1.00
1.38
1.38
1.75
1.75
1.75
2.00

UT

4.50
5.75
6.25
8.00
8.50
10.00
11.50

Add Stroke
LB

5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

XG

Add Stroke
ZB Max.

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

1.88
2.25
2.25
2.50
2.25
2.75
2.50
2.63
3.00
2.88
2.88
3.25
3.00
3.00
3.25
3.25
3.25
3.38
3.38
3.38
3.38

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

22
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Cap Trunnion Mounting
Style DB
(NFPA Style MT2)

UT
1

XJ + STROKE
ZB + STROKE
P + STROKE
LB + STROKE
EE

.125R MAX.
E4
SQ.

2 TD MM

TL

TL

Table 1 Dimensional and Mounting Data

1
2

Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE

NPTF1

SAE2

1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

0.38
0.63
0.63
0.75
0.88
0.88
1.00

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

TD
+.000
-.001

TL

1.000
1.375
1.375
1.750
1.750
1.750
2.000

1.00
1.38
1.38
1.75
1.75
1.75
2.00

UT

4.50
5.75
6.25
8.00
8.50
10.00
11.50

Add Stroke
LB

5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

Add Stroke
XJ
ZB Max.
4.88
5.25
5.25
5.50
5.38
5.88
5.63
6.25
6.63
6.50
6.75
7.13
6.88
7.38
7.63
7.63
7.63
8.38
8.38
8.38
8.38

6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

23
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Intermediate Fixed Trunnion Mounting
Style DD
(NFPA Style MT4)

ZB + STROKE
P + STROKE
LB + STROKE
EE
BD

UM
1
.125R MAX.
2 MM

UW TD 4

3
E SQ.
TM

TL

G
XI 3

TL

Table 1 Dimensional and Mounting Data

1
2

Bore

BD

1.50
2.00
2.50
3.25
4.00
5.00
6.00

1.25
1.50
1.50
2.00
2.00
2.00
3.00

2.50
3.00
3.50
4.50
5.00
6.50
7.50

EE
NPTF

SAE

1/2
1/2
1/2
3/4
3/4
3/4
1

10
10
10
12
12
12
16

0.38
0.63
0.63
0.75
0.88
0.88
1.00

1.75
1.75
1.75
2.00
2.00
2.00
2.25

1.50
1.50
1.50
1.75
1.75
1.75
2.25

0.38
0.44
0.44
0.56
0.56
0.81
0.88

TD
+.000
-.001
1.000
1.375
1.375
1.750
1.750
1.750
2.000

TL

1.00
1.38
1.38
1.75
1.75
1.75
2.00

TM

3.00
3.50
4.00
5.00
5.50
7.00
8.50

UM

UT

UW

5.00 4.50 3.38


6.25 5.75 4.13
6.75 6.25 4.63
8.50 8.00 5.81
9.00 8.50 6.38
10.50 10.00 7.75
12.50 11.50 10.38

Add Stroke
LB

5.00
5.25
5.38
6.25
6.63
7.13
8.38

2.88
2.88
3.00
3.50
3.75
4.25
4.88

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod
No.

MM
Rod

Min.
XI3

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

2.00
2.38
2.38
2.63
2.38
2.88
2.63
2.75
3.13
3.00
3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

3.44
3.81
3.94
4.19
3.94
4.44
4.19
4.69
5.06
4.94
4.94
5.31
5.06
5.06
5.31
5.31
5.31
6.06
6.06
6.06
6.06

Min. Add Stroke


Stroke
ZB
Max
0
0
0.25
0.25
0.13
0.13
0.13
0.38
0.38
0.38
0.13
0.13
0.13
0
0
0
0
0.25
0.25
0.25
0.25

6.25
6.63
6.69
6.94
6.81
7.31
7.06
7.94
8.31
8.19
8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

Dimension XI to be specified by customer.

24
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore

Heavy Duty Hydraulic Cylinders


Series 2H

Heavy Duty Intermediate Fixed Trunnion Mounting


Style DE
(NFPA Style MT4)

ZB + STROKE
LB + STROKE
P + STROKE
EE
BD

UM
1
.125R MAX.
UW TD 4

A
F

3
E SQ.
TM

TL

MM

TL

G
XI3

Table 1 Dimensional and Mounting Data

1
2

Bore

BD

4.00
5.00
6.00

2.25
2.75
3.25

5.00
6.50
7.50

EE
NPTF1 SAE2
3/4
3/4
1

12
12
16

TD
+.000
-.001

TL

0.88
0.88
1.00

2.00
2.00
2.25

1.75
1.75
2.25

0.56
0.81
0.88

2.000
2.500
3.000

1.75
1.75
2.00

TM

UM

UW

5.50 9.00 6.00


7.00 10.50 7.50
8.50 12.50 9.50

Add Stroke Style DE


Minimum
LB
P
Stroke
6.63
7.13
8.38

3.75
4.25
4.88

0.13
0.00
0.25

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Dimensional and Mounting Data


Bore

4.00

5.00

6.00

Rod
No.

MM
Rod

Min.
XI3

Add Stroke
ZB
Max.

1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

4.94
5.31
5.06
5.06
5.31
5.31
5.31
6.06
6.06
6.06
6.06

1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

3.00
3.38
3.13
3.13
3.38
3.38
3.38
3.50
3.50
3.50
3.50

8.50
8.88
8.63
9.38
9.63
9.63
9.63
10.81
10.81
10.81
10.81

Dimension XI to be specified by customer.

25
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Mounting Information 1.50" to 6.00" Bore


Spherical Bearing Mounting
Style SB









Bore Maximum
Operating
psi1

1.50 1500
2.00
2200
2.50 1450
3.25 1500
4.00 1850
5.00
2000
6.00 1800

ZC + STROKE
XC + STROKE

LUBRICATION
FITTING
1

MA

2
KK
W
A

MS

CD

NR

3
EX

Table 1 Dimensional and Mounting Data


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

Rod No.

MM
Rod

1 (Std.)
2
1 (Std.)
2
1 (Std.)
2
3
1 (Std.)
2
3
1 (Std.)
2
3
1 (Std.)
2
3
4
1 (Std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

Thread
Style
Style
7
9
KK3
KK3

7/16-20

7/16-20
3/4-16

3/4-16
3/4-16

3/4-16

3/4-16
1-14

1-14

1-14
1 1/4-12

1 1/4-12

1 1/4-12
1 1/2-12

1 1/2-12

1 1/2-12

1 1/2-12
1 7/8-12

1 7/8-12

1 7/8-12

1 7/8-12

CD 2

EX

MA

MS

NR

0.75
0.75
1.13
1.13
1.13
1.13
1.13
1.63
1.63
1.63
2.00
2.00
2.00
2.25
2.25
2.25
2.25
3.00
3.00
3.00
3.00

-.0005
.5000

0.44

0.75

0.94

0.63

-.0005
.7500

0.66

1.00

1.38

1.00

-.0005
.7500

0.66

1.00

1.38

1.00

-.0005
1.0000

0.88

1.25

1.69

1.25

-.0005
1.3750

1.19

1.88

2.44

1.63

-.0005
1.7500

1.53

2.50

2.88

2.06

-.0005
2.0000

1.75

2.50

3.31

2.38

Note: for additional dimensions see Series 2H Style BB mount.


1
Maximum operating pressure at 4:1 design factor is based on tensile
strength of material. Pressure ratings are based on standard
commercial bearing ratings.
2
Dimension CD is hole diameter.

Head End Mounted


Angle a
Tan. of a
2.00
.035
2.50
.044
2.50
.044
3.00
.052
2.50
.044
3.00
.052
3.00
.052

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25

Add Stroke
XC
ZC
6.38
6.75
7.25
7.50
7.38
7.88
7.63
8.63
9.00
8.88
9.75
10.13
9.88
10.50
10.75
10.75
10.75
12.13
12.13
12.13
12.13

7.13
7.50
8.25
8.50
8.38
8.88
8.63
9.88
10.25
10.13
11.63
12.00
11.75
13.00
13.25
13.25
13.25
14.63
14.63
14.63
14.63

Threads listed are also for a spherical rod eye which match style 9
or style 7. The spherical rod eye pin diameter matches the cap
pin and (if required) needs to be purchased separately; see 2H/3H
mounting accessories for detailed information.

Mounting Information

Table 2 Recommended maximum swivel angle


on each side of the cylinder centerline.
Bore

1.50
2.00
2.50
3.25
4.00
5.00
6.00

Head End Mounting

Cap End Mounted


Tan. of a
Angle a
.035
2.00
.079
4.50
.079
4.50
.052
3.00
.052
3.00
.052
3.00
.052
3.00

X
X

Cap End Mounting

XL + STROKE

A X
A X

Note: Dimension X is the maximum off center mounting of the


cylinder. To determine dimension X for various stroke lengths
multiply the distance between pivot pin holes by tangent of angle a.
For extended position use X = XL + 2X stroke.

XL + STROKE

26
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Double Rod Models 1.50" to 6.00" Bore


Double Rod Cylinder
Style K

ZM + 2 x STROKE
Y

P + STROKE
LD + STROKE

EE

A
MM

Rod End #1

Rod End #2

Mounting
Styles for
Single Rod
Models
T
TB
TD
J
JB
JJ
C
F
D
DD
DE

Mounting
Styles for
Corresponding
Double Rod
Models1
KT
KTB
KTD
KJ
KJB
KJJ
KC
KF
KD
KDD2
KDE2

Dimensions Shown on
This Page Supplement
Dimensions on
Pages Listed Below
1.50" - 6.00" Bores
Page No.
12
12
12
13
14
15
19
20
22
24
25

Bore

Rod No.

MM
Rod

1 (std.)
2
1 (std.)
2
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
2
3
4
1 (std.)
2
3
4

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500

1.50
2.00
2.50

3.25

4.00

If only one end of these Double Rod Cylinders is to be cushioned,


be sure to specify clearly which end this will be.
2
Specify XI dimension from rod end #1.

5.00

6.00

Replaces
On single rod
mounting styles:

Add Stroke

Add 2X
Stroke

LD

SNK

SSK

ZM

5.63
5.63
6.13
6.13
6.25
6.25
6.25
7.25
7.25
7.25
7.75
7.75
7.75
8.25
8.25
8.25
8.25
9.38
9.38
9.38
9.38
LB

2.88
2.88
2.88
2.88
3.00
3.00
3.00
3.50
3.50
3.50
3.75
3.75
3.75
4.25
4.25
4.25
4.25
4.88
4.88
4.88
4.88
SN

4.13
4.13
3.88
3.88
3.63
3.63
3.63
4.38
4.38
4.38
4.25
4.25
4.25
4.75
4.75
4.75
4.75
5.13
5.13
5.13
5.13
SS

6.88
7.63
7.63
8.13
7.75
8.75
8.25
9.00
9.75
9.50
9.75
10.50
10.00
10.50
11.00
11.00
11.00
11.88
11.88
11.88
11.88

All Mtg.
Styles

All Mtg.
Styles

How to Use Double Rod Cylinder


Dimension Drawings
rod cylinders shown on preceding pages and provide the
information needed to completely dimension a double rod
cylinder.

To determine dimensions for a double rod cylinder, first refer


to the desired single rod mounting style cylinder shown on
preceding pages of this catalog. (See table above.) After
selecting necessary dimensions from that drawing, return
to this page supplement the single rod dimensions with
those shown on drawing at right and dimension table below.
Note that double rod cylinders have a head (Dim. G) at both
ends and that dimension LD replaces LB. The double rod
dimensions differ from, or are in addition to those for single

On a double rod cylinder where the two rod ends are different,
be sure to clearly state which rod end is to be assembled at
which end. Port position 1 is standard. If other than standard,
specify pos. 2, 3 or 4 when viewed from rod end #1 only. See
port position information in Section E.

27
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

Bolt-On Gland Option 2HD & 3HD

Heavy Duty Hydraulic Cylinders


Series 2H

Bolt-On Gland Option


Series 2HD & 3HD
Heavy Duty Hydraulic Cylinders

Now Featuring Optional Bolt-On Gland


For 1.50"- 6.00" Bore Series 2H and
7.00" & 8.00" Bore Series 3H Cylinders
n

Non-threaded gland is clamped between bolt-on circular


retainer and head for simplified service

Polyurethane Rod Seal with multiple sealing edges for


leak proof service

Long inboard rod bearing surface that is lubricated


from within

28
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Parker Series 2HD & 3HD your best choice


in heavy duty hydraulic cylinders
Parker Series 2HD and 3HD hydraulic cylinders offer
increased durability and ease of service with the addition
of a bolt-on rod gland. The 2HD/3HD rod gland was
designed to withstand the toughest applications while
maintaining the original dimensional envelope of the

Series 2H and 3H cylinder. When requesting this option,


please take note of the following page that depicts rod
gland retainer dimensions unique to the rod end of the
2HD/3HD cylinder. All other dimensions will remain the
same as the standard Series 2H or 3H cylinder.

Primary Seal Polyurethane Rod


Seal is a proven leak proof design
completely self-compensating and
self-relieving to withstand variations
and conform to mechanical deflection that may occur. Alternative seal
materials are available to suit your
application.
Secondary Seal Rod Wiper
wipes clean any oil film adhering
to the rod on the extend stroke
and cleans the rod on the
return stroke.

Rod Gland Assembly Bronze


gland is externally removable
without cylinder disassembly. Long
inboard bearing surface is ahead
of the seals assuring lubrication by
cylinder operating fluid.

Gland Assembly
Gland Assembly is externally removable
without cylinder disassembly. An O-ring
is used as a seal between the gland and
head. The rod seal has multiple sealing
edges to produce dry rod performance.
It is molded from a special polyurethane
material that is extremely resistant to
abrasion and extrusion, resulting in
exceptional service life. Wiperseal
cleans rod of dirt, preventing it from
entering the gland and also acts as a
secondary rod seal.

29
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 2H

Catalog HY08-1114-1/NA

Bolt-On Gland Option 2HD & 3HD

2HD / 3HD Rod Gland Dimensional Comparison


WF

KB

MM RD

MM

RT

Bolt On Rod Gland (B)


Bore

1.50
2.00
2.50

3.25

4.00

5.00

6.00

7.00

8.00

Rod
No.

1 (Std.)
2
1 (Std.)
2
1 (Std.)
2
3
1 (Std.)
2
3
1 (Std.)
2
3
1 (Std.)
2
3
4
1 (Std.)
2
3
4
1 (Std.)
2
3
4
5
1 (Std.)
2
3
4
5

MM
Rod

0.625
1.000
1.000
1.375
1.000
1.750
1.375
1.375
2.000
1.750
1.750
2.500
2.000
2.000
3.500
2.500
3.000
2.500
4.000
3.000
3.500
3.000
5.000
3.500
4.000
4.500
3.500
5.500
4.000
4.500
5.000

Tie Rod Retained Gland (R)

2HD Rod Gland Retention

Bolt On Rod Gland Dimensions

Mounting Style
TC, H, HB, TB, TD J, JB1
HH, C, F, D,
DB, DD, DE,
BB, SB
B
R
B
R
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B

R
R
R
R
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B

R
R
R
R
B
B
R
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B

JJ

B
+.000
-.002

RD

RT

KB

VF

WF

B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B

1.124
1.499
1.499
1.999
1.499
2.374
1.999
1.999
2.624
2.374
2.374
3.124
2.624
2.624
4.249
3.124
3.749
3.124
4.749
3.749
4.249
3.749
5.749
4.249
4.749
5.249
4.249
6.249
4.749
5.249
5.749

1.94
2.38
2.38
2.88
2.38
3.47
2.88
2.88
3.72
3.47
3.47
4.25
3.72
3.72
5.94
4.25
5.44
4.25
6.31
5.44
5.94
5.44
7.44
5.94
6.31
6.94
5.94
7.94
6.31
6.94
7.44

0.38
0.38
0.38
0.38
0.38
0.63
0.38
0.38
0.63
0.63
0.63
0.63
0.63
0.63
0.94
0.63
0.88
0.63
0.94
0.88
0.94
0.88
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94
0.94

0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.25
0.19
0.25
0.25
0.25
0.25
0.25
-

0.25
0.50
0.50
0.63
0.50
0.50
0.63
0.63
0.50
0.50
0.50
0.63
0.50
0.50
0.31
0.63
0.31
0.63
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31
0.31

0.63
1.00
0.75
1.00
0.75
1.25
1.00
0.88
1.25
1.13
1.00
1.38
1.13
1.13
1.38
1.38
1.38
1.25
1.25
1.25
1.25
-

1.00
1.38
1.38
1.63
1.38
1.88
1.63
1.63
2.00
1.88
1.88
2.25
2.00
2.00
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25

0.38
0.38
0.63
0.63
0.63
0.63
0.63
0.75
0.75
0.75
0.88
0.88
0.88
0.88
0.88
0.88
0.88
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

B = Bolt-On Gland with Circular Retainer


R = Tie Rod Retained Gland
1
2H J & JB Mounts have reduced pressure ratings. Refer to J and JB mounts in 2H Section for de-rated operating pressure associated with
the use of the 2HD gland.

30
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Catalog HY08-1114-1/NA

High Pressure Hydraulic Cylinders

Heavy Duty Hydraulic Cylinders


Series 3H

High Pressure Hydraulic Cylinders


Series 3H
7.00" through 20.00"

Heavy Duty Service


Industrial Tie-Rod Construction
n

Nominal Pressure 3000 psi

Sixteen Standard Mounting Styles


7.00" and 8.00" Bore
n

Twelve Standard Mounting Styles


10.00" through 20.00" Bore

31
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Design Features

The large bore, high pressure hydraulic cylinder


Parker designed to meet your needs
Parker Series 3H cylinders provide unmatched reliability,
performance, and innovative design features that aid in
increasing productivity while reducing operating costs.

innovative design features such as: anti-extrusion body


end seals, floating cushions, hi load piston (standard),
and various port and rod end options to meet your
application requirements.

Parkers externally removable bolt-on gland assembly


makes preventive and routine maintenance quick and
easy! In many cases, the cylinder does not have to
be removed or disassembled to facilitate service. Our
innovative design provides for fast turn around, reduced
downtime, and increased productivity.

Every Series 3H cylinder is individually tested before


leaving our plant to assure proper and leak free
operation. All Series 3H cylinders come with an 18
month warranty standard.

In addition to our patented removable gland assembly,


Series 3H cylinders also include a multitude of

32
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Table of Contents

Section B
Series 3H
Heavy Duty Hydraulic Cylinders
7.00" & 8.00" Bore

10.00" through 20.00" Bore

Specifications, Mounting Styles

34

35

3H Cylinder Model Code & How to Order

36

36

Rod End Styles and Dimensions

38

39

TB, TC and TD Dimensions

40

53

J Mount Dimensions

43

JB Mount Dimensions

44

56

JJ Mount Dimensions

45

54, 55

C Mount Dimensions

46

59

F Mount Dimensions

46

HH Mount Dimensions

42

57

HB Mount Dimensions

42

58

H Mount Dimensions

41

BB Mount Dimensions

47

60

D Mount Dimensions

48

61

DB Mount Dimensions

49

62

DD Mount Dimensions

50

63

DE Mount Dimensions

51

Double Rod End Cylinders

52

64

33
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Specifications / Mountings 7.00" and 8.00" Series 3H
Catalog HY08-1114-1/NA

Standard Specifications

Mounting Styles 16 standard styles at various


application ratings
Strokes Available in any practical stroke length
Cushions Optional at either end or both ends of stroke
Rod Ends Four Standard Choices specials to order

Heavy Duty Service ANSI/(NFPA) T3.6.7R2 - 1996


Specifications and Mounting Dimension Standards
Standard Construction Square Head Tie Rod Design
Nominal Pressure 3000 psi1
Standard Fluid Hydraulic Oil
Standard Temperature -10F to +165F 2
Piston Rod Diameter 3.000" through 5.500"

If hydraulic operating pressure exceeds 3000 psi, send application


data for engineering evaluation and recommendation. See Section E
for actual design factors.
2
See Section E for higher temperature service.
1

In line with our policy of continuing product improvement,


specifications in this catalog are subject to change.

Available Mounting Styles


Tie Rods Extended Head End

(NFPA MX3)

Tie Rods Extended Both Ends

Tie Rods Extended Cap End

Style TB
7.00" &
8.00"

Style TC
7.00" &
8.00"

(NFPA MX2)

Head Square Flange

(NFPA MX1)

(NFPA MF5)

Style JJ
7.00" &
8.00"

(NFPA ME5)

Cap Rectangular

Side Lug

Head Trunnion

Style BB
7.00" &
8.00"

(NFPA MP1)

(NFPA MS4)
Intermediate Fixed Trunnion
Style DB
7.00" &
8.00"

(NFPA MT2)

(NFPA MT1)

Cap Fixed Clevis


Style F
7.00" &
8.00"

Cap Trunnion
Style D
7.00" &
8.00"

Style HB
7.00" &
8.00"

(NFPA MF6)

Side Tapped
Style C
7.00" &
8.00"

(NFPA MS2)

(NFPA ME6)

Cap Square Flange

Style H
7.00" &
8.00"

(NFPA MF2)

Style HH
7.00" &
8.00"

Style J
7.00" &
8.00"

(NFPA MF1)

Cap Rectangular Flange

Head Rectangular

Style JB
7.00" &
8.00"

Head Rectangular Flange

Style TD
7.00" &
8.00"

HD Intermediate Trunnion Mount

Style DD
7.00" &
8.00"

(NFPA MT4)

Style DE1
7.00" &
8.00"

(NFPA MT4)

Double Rod Cylinders


Style KT Shown

Style DE Mount conforms to NFPA MT4 dimensional standard.


NOTE: Series 3H Hydraulic Cylinders fully meet ANSI/(NFPA)
T3.6.7R2 - 1996 Specifications and Mounting Dimension Standards
for Square Head Industrial Fluidpower Cylinders.

Most of the above illustrated


mounting styles are available
in double rod cylinders.

34
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Specifications / Mountings Large Bore


Standard Specifications

Heavy Duty Service


Standard Construction Square Head
Tie Rod Design
Nominal Pressure 3000 psi1
Standard Fluid Hydraulic Oil
Standard Temperature -10F to +165F2
Bore Sizes 10.00" through 20.00"
(Larger sizes available)

Piston Rod Diameter 4.500" through 10.000"


Mounting Styles 12 standard styles at various
application ratings
Strokes Available in any practical stroke length
Cushions Optional at either end or both ends
of stroke
Rod Ends Three Standard Choices Specials
to Order

If hydraulic operating pressure exceeds 3000 psi, send application data for engineering evaluation and recommendation.
See Section E for actual design factors.
2
See Section E for higher temperature service.
In line with our policy of continuing product improvement, specifications in this catalog are subject to change.
1

Available Mounting Styles


Tie Rods Extended Head End
Style TB
10.00"14.00"

(NFPA MX3)

(NFPA MX1)
Style HH
10.00"20.00"

Style JB
10.00"20.00"

(NFPA ME6)

(NFPA MF5)
Cap Fixed Clevis
Style BB
10.00"20.00"

Style D
10.00"14.00"

Style C
10.00"14.00"

(NFPA MS2)

Cap Trunnion

(NFPA MT1)

Side Lug

Style HB
10.00"20.00"

(NFPA MF6)

Head Trunnion

Style JJ
10.00"14.00"

(NFPA ME5)

Cap Square Flange

Cap Rectangular

Head Rectangular

Style TD
10.00"14.00"

Style TC
10.00"14.00"

(NFPA MX2)

Head Square Flange

(NFPA MP1)

Tie Rods Extended Both Ends

Tie Rods Extended Cap End

Intermediate Fixed Trunnion


Style DD
10.00"20.00"

Style DB
10.00"14.00"

(NFPA MT2)

(NFPA MT4)

Double Rod Cylinders


Style KC Shown

Most of the
above illustrated
mounting styles
are available
in double rod
cylinders.

35
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

How To Order

3H Model Code
8.00

Bore Dia.

Cushion
Head

Double
Rod End
Cylinder

Mounting
Style

Mounting
Modification

Specify
bore dia.
in inches
7.00
8.00
10.00
12.00
14.00
16.00
18.00
20.00

Use C
only if head
end cushion
is required.

Use K only
if a double
rod end
cylinder is
required.1

P = Use only if
Thrust Key
required.4

(Style C or F)
M = Use only for
Manifold Port
O-Ring Seal.
Applies to C
Mount only.

T = Basic, No Mount

TB = Tie Rods Ext. Head


TC = Tie Rods Ext. Cap
TD = Tie Rods Ext. Both Ends
J = Head Rectangular Flange
Limited to 7.00" & 8.00" bore
JB = Head Square Flange
JJ = Head Rectangular
H = Cap Rectangular Flange
Limited to 7.00" & 8.00" bore
HB = Cap Square Flange
HH = Cap Rectangular
C = Side Lug2
F = Side Tapped 2
Limited to 7.00" & 8.00" bore
BB = Cap Fixed Clevis
D = Head Trunnion
Limited to 7.00" - 14.00" bore
DB = Cap Trunnion
Limited to 7.00" - 14.00" bore
DD = Int. Fixed Trunnion3
DE = Heavy Duty Int. Fixed Trunnion3
Limited to 7.00" & 8.00" bore

3H

TB

Series
Combination
Designator
Mounts5

Any practical
mounting
style listed.

3H
3HD4

Piston Seal

Ports

L = Lip Seal
Piston
K = Hi Load Piston
(Std.)
F = Low Friction6
C = Ring Packed
Piston
S = Spring Loaded
PTFE piston
seals4

T = SAE Straight Thread O-Ring (Std.)


U = NPTF Ports (Dry Seal Pipe Thread)
R = BSP Ports Parallel Thread ISO 228)
P = SAE Flange Ports (3,000 psi)
B = BSPT Ports (Taper Thread)
G = Metric Thread Ports
Y = Metric Thread Ports per ISO 6149
M = Used only for Manifold Port O-ring
Seal. This option is limited to 7.00"
and 8.00" bore and applies to C
mount only.

Shaded boxes identify required model number fields.


Available mounting styles for K Type cylinders are located at the
end of Section B. When ordering a double rod end cylinder, the
piston rod number and piston rod end threads are to be specified
for both rod ends.
The model number should be created as viewing the primary rod
end on the left hand side.
Example: K Type Cylinder:
7.00CKTD3HLT14A28AC10.000
2
Mounting Styles C and F should have a minimum stroke length
equal to or greater than their bore size.
3
Specify XI dimension.
4
Limited to 7.00" and 8.00" bore.
5
In general, the model numbers as read left to right corresponding
to the cylinder as viewed from left to right with the primary end at
the left. The second or subsequent mountings are mountings called
out as they appear in the assembly moving away from the rod end.
Except when tie rod extension mountings are part of a combination,
all combinations should have a S (Special) in the model code and
a note in the body of the order clarifying the mounting arrangement.
The P, as used to define a thrust key is not considered to be a
mounting. However it is located at the primary end.
6
Low Friction Piston Seal limited to 7.00" and 8.00" bore.
1

36
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

How To Order

3H Model Code
J

16.000

Common
Modification 7

Special
Modification

Piston Rod
Number 11

Piston Rod
End

Piston Rod
Threads

Cushion Cap

Stroke10

Use only if special


modifications are
required:
Oversize Ports
Port Position Change
Special Seals
Stop Tube 10
Stroke Adjusters
Tie Rod Supports

1
2
3
4
5

Used only
if cushion
required

Specify
in inches

J = High Water Content Fluid


V = Fluorocarbon Seals
W = Water Service
X = EPR Seals
H = Class 8 Seals8
N = High Temperature Gland 9

Select:
Style 4 Small Male
Style 8 Intermediate Male
Style 9 Short Female12
Style 55 Rod End for Flange
Coupling
Style 3 Special (Specify) 13

A = UNF Standard
M = Metric14

Shaded boxes identify required model number fields.


See common modifications Section D for additional options.
Class 8 seal option limited to 7.00" & 8.00" bore cylinders.
9
Energized PTFE rod seals & wiperseal are limited to rod sizes of
5.500" and smaller in 7.00" & 8.00" bore size. All other cylinder
seals are fluorocarbon.
10
S = Stop Tube. Specify: stop tube length, net stroke and gross
stroke. Gross stroke = stop tube length + net stroke. Gross stroke to
be placed in the model number field.
Example:

2.000 inches long stop tube
+14.000 inches net stroke
16.000 inches gross stroke
11
Refer to Rod buckling chart in Section E to assure rod number
selected will not buckle under load.
12
Style 9 stroke restrictions may apply. See Style 9 minimum stroke
table for details.
13
Provide dimensions for KK, A, W or WF. If otherwise special,
furnish dimensioned sketch.
14
See Section D for detailed information regarding standard metric
rod end thread sizes.
7
8

Style 9 Minimum Stroke Table


Bore

Rod

Minimum
Stroke

Bore

Rod

Minimum
Stroke

7.00

3.000
3.500
4.000
5.000
3.500
4.000
5.000
5.500
4.500
5.000
5.500
7.000

1.250
1.500
1.500
3.125
1.500
1.500
2.875
3.625
1.125
1.375
2.000
3.125

12.00

5.500
7.000
8.000
7.000
8.000
10.000
8.000
9.000
10.000
9.000
10.000
10.000

1.250
2.375
1.125
2.000
2.750
4.250
1.750
2.500
3.250
1.500
2.250
1.250

8.00

10.00

37
www.parker.com/cylinder

14.00

16.00

18.00
20.00

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Piston Rod Ends 7.00" and 8.00" Bore


Rod End Dimensions 7.00" and 8.00" Bore
Thread Style 4 (NFPA Style SM)
Small Male
A

Thread Style 8 (NFPA Style IM)


Intermediate Male

WF
V

KK

CC
MM RD

B
D WRENCH
FLATS

MM RD

B
D WRENCH
FLATS

NA
KB

KB

RT

Thread Style 551

A
WF
V

KK
B

NA

RT

Thread Style 92 (NFPA Style SF)


Small Female

D WRENCH
FLATS

WF
V

.06R

MM RD

MM RD

AM
AF

NA
KB

KB

AE

RT

AD

RT

WG

Rod End Dimensions 7.00" & 8.00" Bore


Bore

7.00

8.00

Rod
No.

MM
Rod

Thread
Style
Style
8
4&9
CC
KK

1 (std.)
2

3.000
5.000

Rod Extensions and Pilot Dimensions


D
KB
NA
V
RD

B
+.000
-.002

3.50

3.749

2.63

0.250

2.88

0.63

5.00

5.749

-3

0.000

4.88

0.25

3.500

2 3/4-12 2 1/4-12
4 3/4-12 3 1/2-12
3 1/4-12 2 1/2-12

3.50

4.249

3.00

0.250

3.38

0.63

5.75

4.000

3 3/4-12

4.749

3.38

0.250

3.88

0.50

6.50

0.75

2.25

4.500

3-12
4 1/4-12 3 1/4-12

4.00

4.50

5.249

-3

0.250

4.38

0.50

7.00

0.75

2.25

1 (std.)

3.500
5.500

4.249

3.00

0.250

3.38

0.63

5.75

0.63

2.25

5.50

6.249

-3

0.000

5.38

0.25

8.25

1.00

2.25

4.000

3 1/4-12 2 1/2-12
5 1/4-12
4-12
3 3/4-12
3-12

3.50

4.00

4.749

3.38

0.250

3.88

0.50

6.50

0.75

2.25

4.500

4.50

5.249

-3

0.250

4.38

0.50

7.00

0.75

2.25

5.000

5.00

5.749

-3

0.000

4.88

0.25

7.25

1.00

2.25

4 1/4-12 3 1/4-12
4 3/4-12 3 1/2-12

RT

WF

5.25

0.63

2.25

7.25

1.00

2.25

0.63

2.25

Style 55 Rod End

Special Thread Style 3


Special thread, extension, rod eye, blank, etc., are also
available.
To order, specify Style 3 and give desired dimensions for KK,
A, W or WF. If otherwise special, furnish dimensioned sketch.
1

For special WG dimension, specify Style 3 and give desired


dimension for WG. For other changes, place S in the model code,
and describe rod end with dimensioned sketch.
2
Style 9 stroke restrictions may apply. See Style 9 Minimum Stroke
Table on How to Order page for details.
3
These piston rod numbers will have 4 spanner wrench holes instead
of wrench flats. See rod drawings on next page for dimensions.

MM
Rod

3.000
3.500
4.000
4.500

AD

AE
+.001
-.001

AF

AM

WG1

2.44
2.69
2.69
3.19

0.874
0.999
0.999

2.25
2.50
3.00

2.95
3.45
3.95

4.88
5.63
5.75

1.499

3.50

4.45

6.50

5.000

3.19

3.88

4.95

6.63

5.500

3.94

1.499
1.874

4.38

5.45

7.50

38
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Piston Rod Ends Large Bore


Rod End Dimensions 10.00" - 20.00" Bore
Thread Style 4 (NFPA Style SM)
Small Male
A

Thread Style 551


Flanged Rod End
A

WF
F

MM RDB

AF

.515 DIA. AE
x .75 DEEP NA
4 HOLES
V

.515 DIA.
x .75 DEEP NA
4 HOLES
V

.515 DIA.
x .75 DEEP
V
AD 4 HOLES
WG

KK

KK

MM RD
B

AM

A
WF
F

A
WF
F

WF
F
.06R

KK

KK

Thread Style 92 (NFPA Style SF)


Small Female

MM RD
MM B RD

.515 DIA.
x .75 DEEP
4 HOLES

NA

MM RD

NA

Rod End Dimensions 10.00" - 20.00" Bore


Bore

10.00

12.00

14.00

16.00

18.00
20.00

Rod
No.

MM
Rod

Thread
Style
4&9
KK

Rod Extensions and Pilot Dimensions


A

B
+.000
-.005

1 (std.)

4.500

3 1/4-12

4.50

7.000

5-12

7.00

5.000

3 1/2-12

5.00

5.500

4-12

5.50

1 (std.)

5.500

4-12

8.000

NA

RD

WF

5.249

1.94

4.38

8.25

0.25

2.94

7.999

1.94

6.88

10.50

0.38

3.50

5.749

1.94

4.88

8.88

0.25

3.19

6.249

1.94

5.38

9.38

0.25

3.19

5.50

6.249

1.94

5.38

9.38

0.25

3.19

5 3/4-12

8.00

8.999

1.94

7.88

12.50

0.38

4.00

7.000

5-12

7.00

7.999

1.94

6.88

10.50

0.38

3.50

1 (std.)

7.000

5-12

7.00

7.999

1.94

6.88

10.50

0.38

3.50

10.000

7 1/4-12

10.00

10.999

1.94

9.88

14.50

0.38

4.50

8.000

5 3/4-12

8.00

8.999

1.94

7.88

12.50

0.38

4.00

8.000

5 3/4-12

8.00

8.999

1.94

7.88

12.50

0.38

4.00

9.000

6 1/2-12

9.00

9.999

1.94

8.88

13.50

0.38

4.25

10.000

7 1/4-12

10.00

10.999

1.94

9.88

14.50

0.38

4.50

9.000

6 1/2-12

9.00

9.999

1.94

8.88

13.50

0.38

4.25

10.000

7 1/4-12

10.00

10.999

1.94

9.88

14.50

0.38

4.50

10.000

7 1/4-12

10.00

10.999

1.94

9.88

14.50

0.38

4.50

Style 55 Rod End

Special Thread Style 3


Special thread, extension, rod eye, blank, etc., are also
available.
To order, specify Style 3 and give desired dimensions for KK,
A, W or WF. If otherwise special, furnish dimensioned sketch.
1

For special WG dimension, specify Style 3 and give desired


dimension for WG. For other changes, place S in the model code,
and describe rod end with dimensioned sketch.
2
Style 9 stroke restrictions may apply. See Style 9 Minimum Stroke
Table on How to Order page for details.

MM
Rod

4.500
5.000

AD

AE
+.001
-.001

AF

AM

WG1

3.19
3.19

1.499

3.50

4.45

6.50

3.88

4.95

6.63

5.500

3.94

1.499
1.874

4.38

5.45

7.50

7.000

4.06

1.999

5.75

6.95

8.44

8.000

4.06

1.999

9.000
10.000

4.63

2.374

6.50
7.25

7.95
8.95

8.69
8.75

4.63

2.38

8.00

9.95

9.75

39
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Tie Rods Extended Both Ends


Style TD
(NFPA Style MX1)

P + STROKE
ZJ + STROKE
LG + STROKE
EE

Y
WF
DD

MM

AA
3
R SQ.
E SQ.

BB

K
BB

Basic Mounting (T) NFPA MXO Not shown is no tie rod extended and can be supplied upon request.

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

AA

BB

DD

EE
NPTF1 SAE2

1 (std.) 3.000

9.31

4.13 1 1/8-12 8.50

1 1/4

WF

Add Stroke
LG
P
ZJ

20

2.75

2.75

1.16

6.58

2.25

3.69

8.50

5.000

9.31

4.13 1 1/8-12 8.50

1 1/4

20

2.75

2.75

1.16

6.58

2.25

3.69

8.50

3.500

9.31

4.13 1 1/8-12 8.50

1 1/4

20

2.75

2.75

1.16

6.58

2.25

3.69

8.50

4.000

9.31

4.13 1 1/8-12 8.50

1 1/4

20

2.75

2.75

1.16

6.58

2.25

3.69

8.50

4.500

9.31

4.13 1 1/8-12 8.50

1 1/4

20

2.75

2.75

1.16

6.58

2.25

3.69

8.50

1 (std.) 3.500 10.61 4.50 1 1/4-12 9.50

1 1/2

24

3.00

3.00

1.28

7.50

2.25

3.81

9.50

5.500 10.61 4.50 1 1/4-12 9.50

1 1/2

24

3.00

3.00

1.28

7.50

2.25

3.81

9.50

4.000 10.61 4.50 1 1/4-12 9.50

1 1/2

24

3.00

3.00

1.28

7.50

2.25

3.81

9.50

4.500 10.61 4.50 1 1/4-12 9.50

1 1/2

24

3.00

3.00

1.28

7.50

2.25

3.81

9.50

5.000 10.61 4.50 1 1/4-12 9.50

1 1/2

24

3.00

3.00

1.28

7.50

2.25

3.81

9.50

7.00

8.00

5.63 10.75
5.63 10.75
5.63 10.75
5.63 10.75
5.63 10.75
6.38 11.75
6.38 11.75
6.38 11.75
6.38 11.75
6.38 11.75

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
1

Style TB

Style TC

Dimensions for TB and TC Mount may be obtained from the above dimensional table.

40
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Cap Rectangular Flange Mounting


Style H
(NFPA Style MF2)

ZF + STROKE
P + STROKE
XF + STROKE
LG + STROKE
EE

Y
WF

UF
1

MM

4 R E

3
E
TF

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

8.00

EE

NPTF SAE
1

FB

TF

UF

WF

Add Stroke
LG

XF

8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 2.25 3.69 8.50 5.63 10.75 11.75

5.000

8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 2.25 3.69 8.50 5.63 10.75 11.75

3.500

8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 2.25 3.69 8.50 5.63 10.75 11.75

4.000

8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 2.25 3.69 8.50 5.63 10.75 11.75

4.500

8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 2.25 3.69 8.50 5.63 10.75 11.75

1 (std.) 3.500

9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 2.25 3.81 9.50 6.38 11.75 12.75

5.500

9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 2.25 3.81 9.50 6.38 11.75 12.75

4.000

9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 2.25 3.81 9.50 6.38 11.75 12.75

4.500

9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 2.25 3.81 9.50 6.38 11.75 12.75

5.000

9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 2.25 3.81 9.50 6.38 11.75 12.75

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
1

Table 2 Maximum Operating Pressure - 3H & 3HD


Bore

ZF

1 (std.) 3.000
7.00

FB (X4)

Max. psi Pull3


Rod Code
2
3
4

7.00

2000

3000

2000

2500

2800

8.00

1700

2500

1700

1800

2200

Maximum pressure rating pull application.

41
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Cap Square Flange Mounting


Style HB
(NFPA Style MF6)

ZF + STROKE
P + STROKE
XF + STROKE
LG + STROKE
EE

Y
WF

TF
R
1

MM

4 R TF

K
G

3
E SQ.
UF SQ.

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

1 (std.)
2
3
7.00
4
5
1 (std.)
2
3
8.00
4
5
1
2

MM
Rod

EE

3.000
5.000
3.500
4.000
4.500
3.500
5.500
4.000
4.500
5.000

8.50
8.50
8.50
8.50
8.50
9.50
9.50
9.50
9.50
9.50

FB

1.19
1.19
1.19
1.19
1.19
1.31
1.31
1.31
1.31
1.31

2.75
2.75
2.75
2.75
2.75
3.00
3.00
3.00
3.00
3.00

NPTF1 SAE2
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2

20
20
20
20
20
24
24
24
24
24

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

J
2.75
2.75
2.75
2.75
2.75
3.00
3.00
3.00
3.00
3.00

K
1.16
1.16
1.16
1.16
1.16
1.28
1.28
1.28
1.28
1.28

R
6.58
6.58
6.58
6.58
6.58
7.50
7.50
7.50
7.50
7.50

TF
10.63
10.63
10.63
10.63
10.63
11.81
11.81
11.81
11.81
11.81

UF

WF

12.63
12.63
12.63
12.63
12.63
14.00
14.00
14.00
14.00
14.00

2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25

FB (X8)

Add Stroke

3.69
3.69
3.69
3.69
3.69
3.81
3.81
3.81
3.81
3.81

LG

XF

ZF

8.50
8.50
8.50
8.50
8.50
9.50
9.50
9.50
9.50
9.50

5.63
5.63
5.63
5.63
5.63
6.38
6.38
6.38
6.38
6.38

10.75
10.75
10.75
10.75
10.75
11.75
11.75
11.75
11.75
11.75

11.75
11.75
11.75
11.75
11.75
12.75
12.75
12.75
12.75
12.75

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Cap Rectangular Mounting


Style HH
(NFPA Style ME6)

XF + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

UF
1

MM

4 R E

3
E
TF

Table 1 Dimensional and Mounting Data


Bore

Rod
No

1 (std.)
2
3
7.00
4
5
1 (std.)
2
3
8.00
4
5
1
2

MM
Rod

3.000
5.000
3.500
4.000
4.500
3.500
5.500
4.000
4.500
5.000

8.50
8.50
8.50
8.50
8.50
9.50
9.50
9.50
9.50
9.50

EE
NPTF1 SAE2
1 1/4
20
1 1/4
20
1 1/4
20
1 1/4
20
1 1/4
20
1 1/2
24
1 1/2
24
1 1/2
24
1 1/2
24
1 1/2
24

FB

TF

UF

WF

1.19
1.19
1.19
1.19
1.19
1.31
1.31
1.31
1.31
1.31

2.75
2.75
2.75
2.75
2.75
3.00
3.00
3.00
3.00
3.00

2.75
2.75
2.75
2.75
2.75
3.00
3.00
3.00
3.00
3.00

1.16
1.16
1.16
1.16
1.16
1.28
1.28
1.28
1.28
1.28

6.58
6.58
6.58
6.58
6.58
7.50
7.50
7.50
7.50
7.50

10.63
10.63
10.63
10.63
10.63
11.81
11.81
11.81
11.81
11.81

12.63
12.63
12.63
12.63
12.63
14.00
14.00
14.00
14.00
14.00

2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25

3.69
3.69
3.69
3.69
3.69
3.81
3.81
3.81
3.81
3.81

FB (X4)

Add Stroke
LG
P
XF
8.50 5.63 10.75
8.50 5.63 10.75
8.50 5.63 10.75
8.50 5.63 10.75
8.50 5.63 10.75
9.50 6.38 11.75
9.50 6.38 11.75
9.50 6.38 11.75
9.50 6.38 11.75
9.50 6.38 11.75

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

42
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Head Rectangular Flange Mounting


Style J
(NFPA Style MF1)

UF
1

E R4

3
E
TF

Rod
No.

MM
Rod

8.00

1
2

.25

F
WF

For pressures exceeding those shown use mounting styles JB or JJ.

FB

TF

UF

WF

Add Stroke
LB

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

3.500 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

4.000 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

4.500 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

1 (std.) 3.500 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

5.500 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

4.000 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

4.500 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

5.000 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Bore

Max. psi Push3


Rod Code
1

7.00

1400

800

1200

1100

1000

8.00

1100

800

1000

1000

800

Maximum pressure rating push application.

Table 3 Maximum Operating Pressure 3HD


Bore

ZB
Max.

5.000 8.50

Table 2 Maximum Operating Pressure 3H

1 (std.) 3.000 8.50


7.00

EE
NPTF1 SAE2

MM

FB (X4)

Table 1 Dimensional and Mounting Data


Bore

ZB + STROKE
P + STROKE
LB + STROKE
EE

Max. psi Push3


Rod Code
1

7.00

1000

400

800

400

400

8.00

800

400

700

400

400

Maximum pressure rating push application.

43
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Head Square Flange Mounting


Style JB
(NFPA Style MF5)

UF SQ.
E SQ.
1

MM

TF R 4

ZB + STROKE
P + STROKE
LB + STROKE
EE

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

8.00

1
2

NPTF SAE
1

FB

FB (X8)

.25

TF

F
WF

UF

WF

Add Stroke
LB

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

5.000 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

3.500 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

4.000 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

4.500 8.50

1 1/4

20

1.00 1.19 2.75 2.75 1.16 6.58 10.63 12.63 1.25 2.25 3.69 9.50 5.63 12.31

1 (std.) 3.500 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

5.500 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

4.000 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

4.500 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

5.000 9.50

1 1/2

24

1.00 1.31 3.00 3.00 1.28 7.50 11.81 14.00 1.25 2.25 3.81 10.50 6.38 13.56

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Table 2 Maximum Operating Pressure 3H


Bore

Max. psi Push3


Rod Code
1

7.00

3000

2700

3000

3000

3000

8.00

3000

2300

2500

2500

2500

Maximum pressure rating push application.

Table 3 Maximum Operating Pressure 3HD


Bore

Max. psi Push3


Rod Code
1

ZB
Max.

1 (std.) 3.000 8.50


7.00

EE

3
R
TF

7.00

2500

1500

2200

1500

1500

8.00

2000

1400

2000

1400

1400

Maximum pressure rating push application.

44
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Head Rectangular Mounting


Style JJ
(NFPA Style ME5)

ZB + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

UF
1

E R4

MM

3
E

FB (X4)

TF

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

1 (std.) 3.000
7.00

8.00

1
2

EE
NPTF

SAE

FB

TF

UF

WF

Add Stroke

8.50

1 1/4

20

1.19

2.75

2.75

1.16

6.58

10.63

12.63

2.25

3.69

8.50

5.63

ZB
Max.
12.31

LG

5.000

8.50

1 1/4

20

1.19

2.75

2.75

1.16

6.58

10.63

12.63

2.25

3.69

8.50

5.63

12.31

3.500

8.50

1 1/4

20

1.19

2.75

2.75

1.16

6.58

10.63

12.63

2.25

3.69

8.50

5.63

12.31

4.000

8.50

1 1/4

20

1.19

2.75

2.75

1.16

6.58

10.63

12.63

2.25

3.69

8.50

5.63

12.31

4.500

8.50

1 1/4

20

1.19

2.75

2.75

1.16

6.58

10.63

12.63

2.25

3.69

8.50

5.63

12.31

1 (std.) 3.500

9.50

1 1/2

24

1.31

3.00

3.00

1.28

7.50

11.81

14.00

2.25

3.81

9.50

6.38

13.56

5.500

9.50

1 1/2

24

1.31

3.00

3.00

1.28

7.50

11.81

14.00

2.25

3.81

9.50

6.38

13.56

4.000

9.50

1 1/2

24

1.31

3.00

3.00

1.28

7.50

11.81

14.00

2.25

3.81

9.50

6.38

13.56

4.500

9.50

1 1/2

24

1.31

3.00

3.00

1.28

7.50

11.81

14.00

2.25

3.81

9.50

6.38

13.56

5.000

9.50

1 1/2

24

1.31

3.00

3.00

1.28

7.50

11.81

14.00

2.25

3.81

9.50

6.38

13.56

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

45
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Side Lug Mounting


Style C
(NFPA Style MS2)

US
1

SW
SW

Table 1 Dimensional and Mounting Data


Rod
No.

MM
Rod

EE

7.00

8.00

1
2

SB (X4)
SW
SW

3
E SQ.
TS

NPTF1 SAE2

1 (std.) 3.000 8.50 1 1/4

SB

SU SW

TS

US

WF

SU
SU
SS + STROKE

XS

K
SW

Add Stroke
LG

SS

ZB
Max.

20 2.75 2.75 1.16 1.56 1.75 2.88 1.38 11.25 14.00 2.25 3.63 3.69 8.50 5.63 5.75 12.31

5.000 8.50 1 1/4

20 2.75 2.75 1.16 1.56 1.75 2.88 1.38 11.25 14.00 2.25 3.63 3.69 8.50 5.63 5.75 12.31

3.500 8.50 1 1/4

20 2.75 2.75 1.16 1.56 1.75 2.88 1.38 11.25 14.00 2.25 3.63 3.69 8.50 5.63 5.75 12.31

4.000 8.50 1 1/4

20 2.75 2.75 1.16 1.56 1.75 2.88 1.38 11.25 14.00 2.25 3.63 3.69 8.50 5.63 5.75 12.31

4.500 8.50 1 1/4

20 2.75 2.75 1.16 1.56 1.75 2.88 1.38 11.25 14.00 2.25 3.63 3.69 8.50 5.63 5.75 12.31

1 (std.) 3.500 9.50 1 1/2

24 3.00 3.00 1.28 1.56 1.75 2.88 1.38 12.25 15.00 2.25 3.63 3.81 9.50 6.38 6.75 13.56

5.500 9.50 1 1/2

24 3.00 3.00 1.28 1.56 1.75 2.88 1.38 12.25 15.00 2.25 3.63 3.81 9.50 6.38 6.75 13.56

4.000 9.50 1 1/2

24 3.00 3.00 1.28 1.56 1.75 2.88 1.38 12.25 15.00 2.25 3.63 3.81 9.50 6.38 6.75 13.56

4.500 9.50 1 1/2

24 3.00 3.00 1.28 1.56 1.75 2.88 1.38 12.25 15.00 2.25 3.63 3.81 9.50 6.38 6.75 13.56

5.000 9.50 1 1/2

24 3.00 3.00 1.28 1.56 1.75 2.88 1.38 12.25 15.00 2.25 3.63 3.81 9.50 6.38 6.75 13.56

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

Rod
No.

MM
Rod

1 (std.) 3.000 8.50


2
5.000 8.50
7.00

8.00

EE

NPTF1 SAE2

MM

-.005
E/2 -.010

Table 1 Dimensional and Mounting Data


Bore

ZB + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

E 4
SQ.

ST

SW
XS

Side Tapped Mounting


Style F
(NFPA Style MS4)

MM
-.005
E/2 -.010

ST

Bore

ZB + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

3
TN

NT THREAD, ND DEEP
4 TAPPED MTG. HOLES

ND

NT

TN

XT

WF

XT

SN + STROKE

Add Stroke
LG

SN

1 1/4
1 1/4

20

ZB
Max.
2.75 2.75 1.16 1.13 1 1/2-6 3.75 2.25 3.81 3.69 8.50 5.63 5.88 12.31

20

2.75 2.75 1.16 1.13 1 1/2-6 3.75 2.25 3.81 3.69 8.50 5.63 5.88 12.31

3.500 8.50

1 1/4

20

2.75 2.75 1.16 1.13 1 1/2-6 3.75 2.25 3.81 3.69 8.50 5.63 5.88 12.31

4.000 8.50

1 1/4

20

2.75 2.75 1.16 1.13 1 1/2-6 3.75 2.25 3.81 3.69 8.50 5.63 5.88 12.31

4.500 8.50

1 1/4

20

2.75 2.75 1.16 1.13 1 1/2-6 3.75 2.25 3.81 3.69 8.50 5.63 5.88 12.31

1 (std.) 3.500 9.50


2
5.500 9.50

1 1/2
1 1/2

24

3.00 3.00 1.28 1.50 1 1/2-6 4.25 2.25 3.94 3.81 9.50 6.38 6.63 13.56

24

3.00 3.00 1.28 1.50 1 1/2-6 4.25 2.25 3.94 3.81 9.50 6.38 6.63 13.56

4.000 9.50

1 1/2

24

3.00 3.00 1.28 1.50 1 1/2-6 4.25 2.25 3.94 3.81 9.50 6.38 6.63 13.56

4.500 9.50

1 1/2

24

3.00 3.00 1.28 1.50 1 1/2-6 4.25 2.25 3.94 3.81 9.50 6.38 6.63 13.56

5.000 9.50

1 1/2

24

3.00 3.00 1.28 1.50 1 1/2-6 4.25 2.25 3.94 3.81 9.50 6.38 6.63 13.56

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.

46
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Cap Fixed Clevis Mounting


Style BB
(NFPA Style MP1)

ZC + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

PIVOT PIN
CD

MM

4 E
SQ.

2
MR
K

LR
L

3
CB

CW

XC + STROKE

CW

Table 1 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

CB

CD3
+.000
-.002

CW

EE
NPTF1 SAE2

1 (std.) 3.000
2
5.000

3.00
3.00

2.501
2.501

1.50

8.50

1 1/4

1.50

8.50

1 1/4

LR

MR

WF

20

2.75

2.75

1.16

3.00

2.75

2.88

2.25

3.69

20

2.75

2.75

1.16

3.00

2.75

2.88

2.25

3.69

3.500

3.00

2.501

1.50

8.50

1 1/4

20

2.75

2.75

1.16

3.00

2.75

2.88

2.25

3.69

4.000

3.00

2.501

1.50

8.50

1 1/4

20

2.75

2.75

1.16

3.00

2.75

2.88

2.25

3.69

4.500

3.00

2.501

1.50

8.50

1 1/4

20

2.75

2.75

1.16

3.00

2.75

2.88

2.25

3.69

1 (std.) 3.500
2
5.500

3.00
3.00

3.001
3.001

1.50

9.50

1 1/2

24

3.00

3.00

1.28

3.25

3.25

3.13

2.25

3.81

1.50

9.50

1 1/2

24

3.00

3.00

1.28

3.25

3.25

3.13

2.25

3.81

4.000

3.00

3.001

1.50

9.50

1 1/2

24

3.00

3.00

1.28

3.25

3.25

3.13

2.25

3.81

4.500

3.00

3.001

1.50

9.50

1 1/2

24

3.00

3.00

1.28

3.25

3.25

3.13

2.25

3.81

5.000

3.00

3.001

1.50

9.50

1 1/2

24

3.00

3.00

1.28

3.25

3.25

3.13

2.25

3.81

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
3
Dimension CD is pin diameter.
1

Table 2 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

WF
LG

Add Stroke
P
XC

1 (std.) 3.000
2
5.000
7.00
3
3.500
4
4.000

2.25
2.25
2.25
2.25

8.50
8.50
8.50
8.50

5.63
5.63
5.63
5.63

13.75
13.75
13.75
13.75

4.500

2.25

8.50

5.63

13.75

1 (std.) 3.500
2
5.500
3
4.000
8.00

2.25
2.25
2.25

9.50
9.50
9.50

6.38
6.38
6.38

15.00
15.00
15.00

17.75
17.75

4.500

2.25

9.50

6.38

15.00

17.75

5.000

2.25

9.50

6.38

15.00

17.75

ZC
16.25
16.25
16.25
16.25
16.25

17.75

47
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Head Trunnion Mounting


Style D
(NFPA Style MT1)

ZB + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

UT
1
.125R MAX.
E
4
SQ.

2 TD MM

TL

TL

XG

Table 1 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

EE
NPTF1 SAE2

TD
+.000
-.002

TL

UT

WF

XG

1 (std.)
2

3.000
5.000

8.50
8.50

1 1/4
1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

3.63

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

3.500

8.50

3.63

1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

3.63

4.000

4.500

8.50

1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

3.63

8.50

1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

1 (std.)

3.63

9.50
9.50

1 1/2
1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

3.75

3.500
5.500

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

3.75

4.000

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

3.75

4.500

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

3.75

5.000

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

3.75

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
1

Table 2 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

LG

Add Stroke
P

ZB
Max.

1 (std.)
2

3.000
5.000

8.50
8.50

5.63
5.63

12.31
12.31

3.500

8.50

5.63

12.31

4.000

8.50

5.63

12.31

4.500

8.50

5.63

12.31

1 (std.)
2

3.500
5.500

9.50
9.50

6.38
6.38

13.56
13.56

4.000

9.50

6.38

13.56

4.500

9.50

6.38

13.56

5.000

9.50

6.38

13.56

48
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Cap Trunnion Mounting


Style DB
(NFPA Style MT2)

ZB + STROKE
P + STROKE
LG + STROKE
EE

Y
WF

UT
1
.125R MAX.
E 4
SQ.

2 TD MM

TL

G
XJ + STROKE

TL

Table 1 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

EE
NPTF1 SAE2

TD
+.000
-.002

TL

UT

WF

1 (std.)
2

3.000
5.000

8.50
8.50

1 1/4
1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

3.500

8.50

4.000

8.50

1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

3.69

1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

4.500

3.69

8.50

1 1/4

20

2.75

2.75

1.16

2.500

2.50

13.50

2.25

1 (std.)

3.69

9.50
9.50

1 1/2
1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

3.500
5.500

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

4.000

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

4.500

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

5.000

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00

15.50

2.25

3.81

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
1

Table 2 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

LG

Add Stroke
P
XJ

1 (std.)
2
3
4
5
1 (std.)
2

3.000
5.000
3.500
4.000
4.500
3.500
5.500

8.50
8.50
8.50
8.50
8.50
9.50
9.50

5.63
5.63
5.63
5.63
5.63
6.38
6.38

9.38
9.38
9.38
9.38
9.38
10.25
10.25

3
4

4.000
4.500

9.50
9.50

6.38
6.38

10.25
10.25

5.000

9.50

6.38

10.25

ZB
Max
12.31
12.31
12.31
12.31
12.31
13.56
13.56
13.56
13.56
13.56

49
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Intermediate Fixed Trunnion Mounting


Style DD
(NFPA Former Standard Style MT4)

ZB + STROKE
P + STROKE
LG + STROKE
EE
BD

Y
WF

UM
1
.125R MAX.

UW

E
SQ.4

2 TD MM

G
3
TM

TL

XI

TL

Table 1 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

BD

1 (std.)
2

MM
Rod

3.000
5.000

EE
NPTF1 SAE2

3.00
3.00

8.50
8.50

1 1/4
1 1/4

3.500

3.00

8.50

4.000

3.00

8.50

1.16

TD
+.000
-.002
2.500

20

2.75

2.75

20

2.75

2.75

1 1/4

20

2.75

1 1/4

20

TL

2.50

1.16

2.500

2.50

2.75

1.16

2.500

2.75

2.75

1.16

TM

UM

UW

WF

Min.
XI3

9.75 14.75 11.50 2.25

3.69

6.56

9.75 14.75 11.50 2.25

3.69

6.56

2.50

9.75 14.75 11.50 2.25

3.69

6.56

2.500

2.50

9.75 14.75 11.50 2.25

3.69

6.56

4.500

3.00

8.50

1 1/4

20

2.75

2.75

1.16

2.500

2.50

9.75 14.75 11.50 2.25

3.69

6.56

1 (std.)

3.50
3.50

9.50
9.50

1 1/2
1 1/2

24

3.00

3.00

1.28

3.000

3.00 11.00 17.00 13.38 2.25

3.81

7.06

3.500
5.500

24

3.00

3.00

1.28

3.000

3.00 11.00 17.00 13.38 2.25

3.81

7.06

4.000

3.50

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00 11.00 17.00 13.38 2.25

3.81

7.06

4.500

3.50

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00 11.00 17.00 13.38 2.25

3.81

7.06

5.000

3.50

9.50

1 1/2

24

3.00

3.00

1.28

3.000

3.00 11.00 17.00 13.38 2.25

3.81

7.06

NPTF ports are available at no extra charge.


2
SAE straight thread ports are standard and are indicated by port number.
3
Dimension XI to be specified by customer.
1

Table 2 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

Style DD
Minimum
Stroke

1 (std.)
2

3.000
5.000

0.13
0.13

3.500

4.000

5
1 (std.)

Add Stroke
LG
P
ZB
Max.
8.50
5.63
12.31
8.50

5.63

12.31

0.13

8.50

5.63

12.31

0.13

8.50

5.63

12.31

4.500

0.13

8.50

5.63

12.31

0.13
0.13

9.50

6.38

13.56

3.500
5.500

9.50

6.38

13.56

4.000

0.13

9.50

6.38

13.56

4.500

0.13

9.50

6.38

13.56

5.000

0.13

9.50

6.38

13.56

50
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Mounting Information 7.00" and 8.00" Bore Series 3H
Catalog HY08-1114-1/NA

Heavy Duty Intermediate Fixed


Trunnion Mounting
Style DE
(NFPA Current Standard Style MT4)

ZB + STROKE
LG + STROKE

WF
Y

UM
E SQ
1

P + STROKE
EE
BD

.125R MAX.
2 MM

UW TD 4

3
TM

TL

XI3

TL

Table 1 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

BD

1 (std.)
2

3.000
5.000

4.000
4.000

8.50
8.50

3
4

3.500
4.000

4.000
4.000

8.50
8.50

5
1 (std.)
2
3

4.500
3.500
5.500
4.000

4.000
4.500
4.500
4.500

8.50
9.50
9.50
9.50

4
5

4.500
5.000

4.500
4.500

9.50
9.50

EE
NPTF1 SAE2
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2

TD
+.000
-.002

TL

20

2.75

2.75

1.16

3.500

2.50

20
20

2.75
2.75

2.75
2.75

1.16
1.16

3.500
3.500

20
20

2.75
2.75

2.75
2.75

1.16
1.16

24
24

3.00
3.00

3.00
3.00

24
24

3.00
3.00

24

3.00

TM

UM

UW

WF

Min
XI3

9.75 14.75 11.38 2.25

3.69

7.06

2.50
2.50

9.75 14.75 11.38 2.25


9.75 14.75 11.38 2.25

3.69
3.69

7.06
7.06

3.500
3.500

2.50
2.50

9.75 14.75 11.38 2.25


9.75 14.75 11.38 2.25

3.69
3.69

7.06
7.06

1.28
1.28

4.000
4.000

3.00 11.00 17.00 12.00 2.25


3.00 11.00 17.00 12.00 2.25

3.81
3.81

7.56
7.56

3.00
3.00

1.28
1.28

4.000
4.000

3.00 11.00 17.00 12.00 2.25


3.00 11.00 17.00 12.00 2.25

3.81
3.81

7.56
7.56

3.00

1.28

4.000

3.00 11.00 17.00 12.00 2.25

3.81

7.56

NPTF ports are available at no extra charge.


SAE straight thread ports are standard and are indicated by port number.
3
Dimension XI to be specified by customer.
1
2

Table 2 Dimensional and Mounting Data


Bore

7.00

8.00

Rod
No.

MM
Rod

Style DE
Minimum
Stroke

1 (std.)
2

3.000
5.000

1.13
1.13

3.500

4.000

5
1 (std.)

Add Stroke
P
ZB
Max.
8.50
5.63
12.31
LG

8.50

5.63

12.31

1.13

8.50

5.63

12.31

1.13

8.50

5.63

12.31

4.500

1.13

8.50

5.63

12.31

1.13
1.13

9.50

6.38

13.56

3.500
5.500

9.50

6.38

13.56

4.000

1.13

9.50

6.38

13.56

4.500

1.13

9.50

6.38

13.56

5.000

1.13

9.50

6.38

13.56

51
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Double Rod Models 7.00" and 8.00" Bore


Double Rod Cylinder
Style K

ZM + 2 x STROKE
P + STROKE

LD + STROKE

WF

EE

MM

Rod End #1

Rod End #2

Mounting Styles Mounting Styles for


for Single Rod
Corresponding
Models
Double Rod Models1

Dimensions Shown on
This Page Supplement
Dimensions on Pages
Listed Below for
7.00" - 8.00" Bores

TB

KTB

40

TD

KTD

40

KJ

43

JB

KJB

44

JJ

KJJ

45

KC

46

KF

46

KD

48

DD

KDD2

50

DE

KDE

51

Bore

Rod
No.

MM
Rod

WF
LD

SNK

SSK

ZM

1 (std.)

3.00

2.25

8.50

5.38

5.75

13.00

5.00

2.25

8.50

5.38

5.75

13.00

3.50

2.25

8.50

5.38

5.75

13.00

4.00

2.25

8.50

5.38

5.75

13.00

7.00

4.50

2.25

8.50

5.38

5.75

13.00

3.50

2.25

9.50

6.13

6.75

14.00

5.50

2.25

9.50

6.13

6.75

14.00

4.00

2.25

9.50

6.13

6.75

14.00

4.50

2.25

9.50

6.13

6.75

14.00

5.00

2.25

9.50

6.13

6.75

14.00

LB

SN

SS

All Mtg.
Styles

Replaces
On single rod
mounting styles:

If only one end of these Double Rod Cylinders is to be cushioned,


be sure to specify clearly which end this will be.
2
Specify XI dimension from rod end #1.

Add 2X
Stroke

1 (std.)
8.00

Add Stroke

All Mtg.
Styles

How to Use Double Rod Cylinder


Dimension Drawings
rod cylinders shown on preceding pages and provide the
information needed to completely dimension a double rod
cylinder.

To determine dimensions for a double rod cylinder, first refer


to the desired single rod mounting style cylinder shown on
preceding pages of this catalog. (See table above.) After
selecting necessary dimensions from that drawing, return
to this page supplement the single rod dimensions with
those shown on drawing at right and dimension table below.
Note that double rod cylinders have a head (Dim. G) at both
ends and that dimension LD replaces LB. The double rod
dimensions differ from, or are in addition to those for single

On a double rod cylinder where the two rod ends are different,
be sure to clearly state which rod end is to be assembled at
which end. Port position 1 is standard. If other than standard,
specify pos. 2, 3 or 4 when viewed from rod end #1 only. See
port position information in Section E.

52
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Tie Rods Extended Both Ends Mounting
Style TD
(NFPA Style MX1)

Z J + STROKE
P + STROKE
LG + STROKE
EE

WF
1

E
SQ. 4

DD

M M

K
BB

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

1 (std.) 4.500
2
7.000
10.00
3
5.000
4
5.500
1 (std.) 5.500
2
8.000
12.00
3
7.000
1 (std.) 7.000
2
10.000
14.00
3
8.000

BB

DD

4.13
4.13
4.13
4.13
4.50
4.50
4.50
4.50
4.50
4.50

1 1/8-12
1 1/8-12
1 1/8-12
1 1/8-12
1 1/4-12
1 1/4-12
1 1/4-12
1 1/4-12
1 1/4-12
1 1/4-12

12.63
12.63
12.63
12.63
14.88
14.88
14.88
17.13
17.13
17.13

EE
NPTF1 SAE
SAE
Flange Straight
Ports2 Thread3
2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50

2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50

24
24
24
24
24
24
24
24
24
24

WF

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88

1.28
1.28
1.28
1.28
1.41
1.41
1.41
1.41
1.41
1.41

2.94
3.50
3.19
3.19
3.19
4.00
3.50
3.50
4.50
4.00

4.75
5.31
5.00
5.00
5.38
6.19
5.69
5.88
6.88
6.38

BB

Add Stroke
LG
P
ZJ

12.13
12.13
12.13
12.13
14.50
14.50
14.50
15.63
15.63
15.63

8.50
8.50
8.50
8.50
10.13
10.13
10.13
10.88
10.88
10.88

15.06
15.63
15.31
15.31
17.69
18.50
18.00
19.13
20.13
19.63

NPTF ports are available at no extra charge.


Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1
2

Table 2 Optional SAE Flange Port Pattern

Table 3 Tie Rod Information

A DIA.

RA
RB

RA
RB
RC

RR

Q
W

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

A
Q
GG W
X
Nom.
Flange
Size
2.00 3.062 1.688 1.53 0.84
2
2 1/2 2.50 3.500 2.000 1.75 1.00

Style TB

Z-THD
UNC2B
1/2-13
1/2-13

RA
RB
RC

RA
RB

14.00" Bore

10.00", 12.00" Bores


AA SAE
Min.
1.06
1.19

Bore
Tie Rod Thread
RA
RB
RC
RR

32
40

10.00 12.00 14.00


1 1/8-12 1 1/4-12 1 1/4-12
5.291 6.270 7.485
3.775 4.555 6.143

4.409
2.13
2.38
2.25

Style TC

Dimensions for TB and TC Mount may be obtained from the above dimensional table.
53
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Head Rectangular Mounting
Style JJ (10"-14" Bore)
(NFPA Style ME5)

UF
TF
1

WF

E R

MM

3
E

Z B + STROKE
P + STROKE
LG + STROKE
EE

FB (X4)

Table 1 Dimensional and Mounting Data


Bore

10.00

12.00

14.00

Rod
No.

MM
Rod

E
NPTF1

1 (std.) 4.500 12.63


2
7.000 12.63

Ports (EE)
SAE
SAE
Flange Straight
Port2 Thread
Port3

FB

TF

UF

WF

Add Stroke
LG
P
ZB
Max.

2.00

2.00

24

1.81 3.69 3.69 1.28

9.62 15.88 19.00 2.94 4.75 12.13 8.50 16.69

2.00

2.00

24

1.81 3.69 3.69 1.28

9.62 15.88 19.00 3.50 5.31 12.13 8.50 17.25

5.000 12.63

2.00

2.00

24

1.81 3.69 3.69 1.28

9.62 15.88 19.00 3.19 5.00 12.13 8.50 16.94

5.500 12.63

2.00

2.00

24

1.81 3.69 3.69 1.28

9.62 15.88 19.00 3.19 5.00 12.13 8.50 16.94

1 (std.) 5.500 14.88

2.50

2.50

24

2.06 4.44 4.44 1.41 11.45 18.50 22.00 3.19 5.38 14.50 10.13 19.44

8.000 14.88

2.50

2.50

24

2.06 4.44 4.44 1.41 11.45 18.50 22.00 4.00 6.19 14.50 10.13 20.25

7.000 14.88

2.50

2.50

24

2.06 4.44 4.44 1.41 11.45 18.50 22.00 3.50 5.69 14.50 10.13 19.75

1 (std.) 7.000 17.13

2.50

2.50

24

2.31 4.88 4.88 1.41 13.26 21.00 25.00 3.50 5.88 15.63 10.88 20.88

2.50

2.50

24

2.31 4.88 4.88 1.41 13.26 21.00 25.00 4.50 6.88 15.63 10.88 21.88

2.50

2.50

24

2.31 4.88 4.88 1.41 13.26 21.00 25.00 4.00 6.38 15.63 10.88 21.38

2
3

10.000 17.13
8.000 17.13

NPTF ports are available at no extra charge.


Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1
2

Table 2 Optional SAE Flange Port Pattern


A DIA.

Q
W

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Q
W
A
X
Nom.
GG
Flange
Size
2.00 3.062 1.688 1.53 0.84
2
2 1/2 2.50 3.500 2.000 1.75 1.00

Z-THD
UNC2B
1/2-13
1/2-13

AA SAE
Min.
1.06
1.19

32
40

54
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Head Rectangular Mounting
Style JJ (16"-20" Bore)
(NFPA Style ME5)

UF
TF
1

EJ

16.00

Rod
No.

MM
Rod

RJ R

MM

FB (X8)

3
E

Table 1 Dimensional and Mounting Data


Bore

WF

ZB + STROKE
P + STROKE
LG + STROKE
EE

EJ

Ports (EE)
FB
G
J
K
R
RJ
TF
UF WF
Y
Add Stroke

SAE
LG
SAE
P
ZB
Flange Straight
Max.
Port1 Thread
Port2
1 (std.) 8.000 19.00 20.00 3.00
24
1.81 5.88 5.88 1.91 15.50 8.00 21.00 24.50 4.00 7.00 18.13 12.13 24.38
3

9.000 19.00 20.00

3.00

24

1.81 5.88 5.88 1.91 15.50 8.00 21.00 24.50 4.25 7.25 18.13 12.13 24.63

10.000 19.00 20.00

3.00

24

1.81 5.88 5.88 1.91 15.50 8.00 21.00 24.50 4.50 7.50 18.13 12.13 24.88

1 (std.) 9.000 22.00 23.00

3.00

24

2.06 6.88 6.88 1.91 18.00 7.25 24.25 28.25 4.25 7.25 21.13 15.13 27.63

10.000 22.00 23.00

3.00

24

2.06 6.88 6.88 1.91 18.00 7.25 24.25 28.25 4.50 7.50 21.13 15.13 27.88

20.00 1 (std.) 10.000 24.00 25.00

3.00

24

2.06 7.88 7.88 1.91 20.00 8.00 26.50 30.50 4.50 7.50 23.63 17.63 30.38

18.00

Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
2
SAE straight thread ports are standard and are indicated by port number.
1

Table 2 Optional SAE Flange Port Pattern


A DIA.

Q
W

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Nom.
Q
X Z-THD AA SAE
A
GG W
UNC- Min.
Flange
2B
Size
3
3.00 4.188 2.438 2.09 1.22 5/8-11 1.19 48

55
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Head Square Flange Mounting
Style JB
(NFPA Style MF5)

EX SQ.
TE
RE
1

WF

TE

MM

RE

3
E SQ.

ZB + STROKE
P + STROKE
LG + STROKE
EE

EB (X8)

Table 1 Dimensional and Mounting Data


Bore Rod
No.

10.00

12.00

14.00

16.00
18.00
20.00

MM
Rod

1 (std.) 4.500
2
7.000
3
5.000
4
5.500
1 (std.) 5.500
2
8.000
3
7.000
1 (std.) 7.000
2
10.000
3
8.000
1 (std.) 8.000
3
9.000
4
10.000
1 (std.) 9.000
3
10.000
1 (std.) 10.000

EB
Ports (EE)
NPTF1 SAE
SAE
Flange Straight
Port2 Thread
Port3

12.63
12.63
12.63
12.63
14.88
14.88
14.88
17.13
17.13
17.13
19.00
19.00
19.00
22.00
22.00
24.00

1.31
1.31
1.31
1.31
1.56
1.56
1.56
1.81
1.81
1.81
1.81
1.81
1.81
2.06
2.06
2.06

2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
-

2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
3.00
3.00
3.00
3.00
3.00
3.00

24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

EX

RE

TE

WF

16.63
16.63
16.63
16.63
19.75
19.75
19.75
21.75
21.75
21.75
24.50
24.50
24.50
26.50
26.50
29.00

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

1.28
1.28
1.28
1.28
1.41
1.41
1.41
1.41
1.41
1.41
1.91
1.91
1.91
1.91
1.91
1.91

9.89
9.89
9.89
9.89
11.75
11.75
11.75
12.90
12.90
12.90
15.28
15.28
15.28
16.45
16.45
18.07

14.13
14.13
14.13
14.13
16.79
16.79
16.79
18.43
18.43
18.43
21.03
21.03
21.03
22.65
22.65
24.87

2.94
3.50
3.19
3.19
3.19
4.00
3.50
3.50
4.50
4.00
4.00
4.25
4.50
4.25
4.50
4.50

4.75
5.31
5.00
5.00
5.38
6.19
5.69
5.88
6.88
6.38
7.00
7.25
7.50
7.25
7.50
7.50

Add Stroke
LG
P
ZB
Max.

12.13
12.13
12.13
12.13
14.50
14.50
14.50
15.63
15.63
15.63
18.13
18.13
18.13
21.13
21.13
23.63

8.50
8.50
8.50
8.50
10.13
10.13
10.13
10.88
10.88
10.88
12.13
12.13
12.13
15.13
15.13
17.63

NPTF ports are available at no extra charge.


Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1
2

Table 2 Optional SAE Flange Port Pattern


A DIA.

Q
W
HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

X
GG

Nom.
Q
A
GG
Flange
Size
2
2.00 3.062 1.688
2 1/2 2.50 3.500 2.000
3
3.00 4.188 2.438

Z-THD AA SAE
UNC- Min.
2B

1.53 0.84 1/2-13 1.06


1.75 1.00 1/2-13 1.19
2.09 1.22 5/8-11 1.19

32
40
48

56
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

16.69
17.25
16.94
16.94
19.44
20.25
19.75
20.88
21.88
21.38
24.38
24.63
24.88
27.63
27.88
30.38

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Cap Rectangular Mounting
Style HH
(NFPA Style ME6)

UF
TF
1

WF

XF + STROKE
P + STROKE
LG + STROKE
EE

(10.00-14.00
Bore)
2

EJ 4
(16.0020.00 only)

MM

FB
(X4) (10.00-14.00)
(X8) (16.00-20.00)

3
E
(10.00-14.00 only)

(16.00-20.00
Bore)

RJ

B
Table 1 Dimensional and Mounting Data
Bore

10.00

12.00

14.00

16.00
18.00
20.00

Rod
No.

MM
Rod

Ports (EE)

1 (std.)
2
3
4
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
3
4
1 (std.)
3
1 (std.)

4.500
7.000
5.000
5.500
5.500
8.000
7.000
7.000
10.000
8.000
8.000
9.000
10.000
9.000
10.000
10.000

12.63
12.63
12.63
12.63
14.88
14.88
14.88
17.13
17.13
17.13
-

SAE
NPTF1 SAE
Flange Straight
Port2 Thread
Port3
2.00
2.00
24
2.00
2.00
24
2.00
2.00
24
2.00
2.00
24
2.50
2.50
24
2.50
2.50
24
2.50
2.50
24
2.50
2.50
24
2.50
2.50
24
2.50
2.50
24
3.00
24
3.00
24
3.00
24
3.00
24
3.00
24
3.00
24

EJ

20.00
20.00
20.00
23.00
23.00
25.00

FB

1.81
1.81
1.81
1.81
2.06
2.06
2.06
2.31
2.31
2.31
1.81
1.81
1.81
2.06
2.06
2.06

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

1.28
1.28
1.28
1.28
1.41
1.41
1.41
1.41
1.41
1.41
1.91
1.91
1.91
1.91
1.91
1.91

9.62
9.62
9.62
9.62
11.45
11.45
11.45
13.26
13.26
13.26
15.50
15.50
15.50
18.00
18.00
20.00

RJ

8.00
8.00
8.00
7.25
7.25
8.00

TF

15.88
15.88
15.88
15.88
18.50
18.50
18.50
21.00
21.00
21.00
21.00
21.00
21.00
24.25
24.25
26.50

UF

19.00
19.00
19.00
19.00
22.00
22.00
22.00
25.00
25.00
25.00
24.50
24.50
24.50
28.25
28.25
30.50

WF

2.94
3.50
3.19
3.19
3.19
4.00
3.50
3.50
4.50
4.00
4.00
4.25
4.50
4.25
4.50
4.50

4.75
5.31
5.00
5.00
5.38
6.19
5.69
5.88
6.88
6.38
7.00
7.25
7.50
7.25
7.50
7.50

Add Stroke
LG

XF

12.13
12.13
12.13
12.13
14.50
14.50
14.50
15.63
15.63
15.63
18.13
18.13
18.13
21.13
21.13
23.63

8.50
8.50
8.50
8.50
10.13
10.13
10.13
10.88
10.88
10.88
12.13
12.13
12.13
15.13
15.13
17.63

15.06
15.63
15.31
15.31
17.69
18.50
18.00
19.13
20.13
19.63
22.13
22.38
22.63
25.38
25.63
28.13

NPTF ports are available at no extra charge.


Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1
2

Table 2 Optional SAE Flange Port Pattern

A DIA.

Nom.
Q
X Z-THD
A
GG W
Flange
UNCSize
2B
2
2.00 3.062 1.688 1.53 0.84 1/2-13
2 1/2 2.50 3.500 2.000 1.75 1.00 1/2-13
3
3.00 4.188 2.438 2.09 1.22 5/8-11

Q
W

X
GG

AA SAE
Min.
1.06
1.19
1.19

32
40
48

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

57
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Cap Square Flange Mounting
Style HB
(NFPA Style MF6)

EX SQ.
TE
RE
1

WF

2 RE

3
E SQ.

TE

P + STROKE
LG + STROKE
EE

MM

EB (X8)

Table 1 Dimensional and Mounting Data


Bore

10.00

12.00

14.00

16.00
18.00
20.00

Rod
No.

MM
Rod

1 (std.)
2
3
4
1 (std.)
2
3
1 (std.)
2
3
1 (std.)
3
4
1 (std.)
3
1 (std.)

4.500
7.000
5.000
5.500
5.500
8.000
7.000
7.000
10.000
8.000
8.000
9.000
10.000
9.000
10.000
10.000

12.63
12.63
12.63
12.63
14.88
14.88
14.88
17.13
17.13
17.13
19.00
19.00
19.00
22.00
22.00
24.00

EB
Ports (EE)
NPTF1 SAE
SAE
Flange Straight
Port2 Thread
Port3
1.31 2.00
2.00
24
1.31 2.00
2.00
24
1.31 2.00
2.00
24
1.31 2.00
2.00
24
1.56 2.50
2.50
24
1.56 2.50
2.50
24
1.56 2.50
2.50
24
1.81 2.50
2.50
24
1.81 2.50
2.50
24
1.81 2.50
2.50
24
1.81
3.00
24
1.81
3.00
24
1.81
3.00
24
2.06
3.00
24
2.06
3.00
24
2.06
3.00
24

XF + STROKE

EX

RE

TE

WF

16.63
16.63
16.63
16.63
19.75
19.75
19.75
21.75
21.75
21.75
24.50
24.50
24.50
26.50
26.50
29.00

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

1.28
1.28
1.28
1.28
1.41
1.41
1.41
1.41
1.41
1.41
1.91
1.91
1.91
1.91
1.91
1.91

9.89
9.89
9.89
9.89
11.75
11.75
11.75
12.90
12.90
12.90
15.28
15.28
15.28
16.45
16.45
18.07

14.13
14.13
14.13
14.13
16.79
16.79
16.79
18.43
18.43
18.43
21.03
21.03
21.03
22.65
22.65
24.87

2.94
3.50
3.19
3.19
3.19
4.00
3.50
3.50
4.50
4.00
4.00
4.25
4.50
4.25
4.50
4.50

4.75
5.31
5.00
5.00
5.38
6.19
5.69
5.88
6.88
6.38
7.00
7.25
7.50
7.25
7.50
7.50

Add Stroke
LG
P
XF

12.13
12.13
12.13
12.13
14.50
14.50
14.50
15.63
15.63
15.63
18.13
18.13
18.13
21.13
21.13
23.63

8.50
8.50
8.50
8.50
10.13
10.13
10.13
10.88
10.88
10.88
12.13
12.13
12.13
15.13
15.13
17.63

NPTF ports are available at no extra charge.


Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1
2

Table 2 Optional SAE Flange Port Pattern


A DIA.

Q
W

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Nom.
Q
X Z-THD
A
GG W
Flange
UNCSize
2B
2
2.00 3.062 1.688 1.53 0.84 1/2-13
2 1/2 2.50 3.500 2.000 1.75 1.00 1/2-13
3
3.00 4.188 2.438 2.09 1.22 5/8-11

AA SAE
Min.
1.06
1.19
1.19

32
40
48

58
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

15.06
15.63
15.31
15.31
17.69
18.50
18.00
19.13
20.13
19.63
22.13
22.38
22.63
25.38
25.63
28.13

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Side Lugs Mounting
Style C
(NFPA Style MS2)

US
E SQ.
1

WF

ZB + STROKE
P + STROKE
LG + STROKE
EE

MM

ST

.000
E/2 +
-.005
3

SW

SW

TS

SW

SW

SB (X4)

SW

J
SU
SU
SS + STROKE

XS

K
SW

Table 1 Dimensional and Mounting Data


Bore

10.00

Rod
No.

MM
Rod

1 (std.) 4.500
2
7.000

14.00

Ports (EE)
NPTF1 SAE
SAE
Flange Straight
Port2 Thread
Port3

SB

ST

SU

SW

TS

US

WF

12.63
12.63

2.00

2.00

24

3.69 3.69 1.28 1.563 2.25 3.50 1.63 4.75 15.88 19.13 2.94 4.56

2.00

2.00

24

3.69 3.69 1.28 1.563 2.25 3.50 1.63 5.31 15.88 19.13 3.50 5.13

5.000

12.63

2.00

2.00

24

3.69 3.69 1.28 1.563 2.25 3.50 1.63 5.00 15.88 19.13 3.19 4.81

5.500

12.63

2.00

2.00

24

3.69 3.69 1.28 1.563 2.25 3.50 1.63 5.00 15.88 19.13 3.19 4.81

14.88

2.50

2.50

24

4.44 4.44 1.41 1.563 3.00 4.25 2.00 5.38 18.88 22.88 3.19 5.19

8.000

14.88

2.50

2.50

24

4.44 4.44 1.41 1.563 3.00 4.25 2.00 6.19 18.88 22.88 4.00 6.00

7.000

14.88

2.50

2.50

24

4.44 4.44 1.41 1.563 3.00 4.25 2.00 5.69 18.88 22.88 3.50 5.50

1 (std.) 7.000

17.13

2.50

2.50

24

4.88 4.88 1.41 2.313 4.00 4.75 2.25 5.88 21.63 26.13 3.50 5.75

10.000 17.13
8.000 17.13

2.50

2.50

24

4.88 4.88 1.41 2.313 4.00 4.75 2.25 6.88 21.63 26.13 4.50 6.75

2.50

2.50

24

4.88 4.88 1.41 2.313 4.00 4.75 2.25 6.38 21.63 26.13 4.00 6.25

2
3

NPTF ports are available at no extra charge.


2
Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1

Table 1 Dimensional and Mounting Data (cont.)


Bore

10.00

12.00

XS

1 (std.) 5.500
12.00

Rod
No.

MM
Rod

LG

1 (std.) 4.500 12.13


2
7.000 12.13

Add Stroke
P
SS

Table 2 Optional SAE Flange Port Pattern


A DIA.

ZB
Max.

8.50

8.88

16.69

8.50

8.88

17.25

5.000 12.13

8.50

8.88

16.94

5.500 12.13

8.50

8.88

16.94

1 (std.) 5.500 14.50 10.13 10.50 19.44


2
8.000 14.50 10.13 10.50 20.25
3
7.000 14.50 10.13 10.50 19.75

1 (std.) 7.000 15.63 10.88 11.13 20.88


14.00
2 10.000 15.63 10.88 11.13 21.88
3
8.000 15.63 10.88 11.13 21.38

Q
W

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Q
W
Nom.
X
A
GG
Flange
Size
2
2.00 3.062 1.688 1.53 0.84
2 1/2 2.50 3.500 2.000 1.75 1.00

59
www.parker.com/cylinder

Z-THD
UNC2B
1/2-13
1/2-13

AA SAE
Min.
1.06
1.19

32
40

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Cap Fixed Clevis Mounting
Style BB
(NFPA Style MP1)

ZC + STROKE
P + STROKE
LG + STROKE
EE

WF

CD
LR

MM

XC + STROKE

4 E
SQ.

MR
PIVOT PIN
FURNISHED
WITH CYLINDER
L

CW

CW
CB

Table 1 Dimensional and Mounting Data


Bore

10.00

12.00

14.00

Rod
No.

MM
Rod

CB CD CW
+.001
-.003

EE Ports

LR MR WF

Add Stroke
LG

XC

ZC

1 (std.) 4.500 4.00 3.500 2.00 12.63 2.00

2.00

24

3.69 3.69 1.28 4.00 3.38 3.50 2.94 4.75 12.13 8.50 19.06 22.56

7.000 4.00 3.500 2.00 12.63 2.00

2.00

24

3.69 3.69 1.28 4.00 3.38 3.50 3.50 5.31 12.13 8.50 19.63 23.13

5.000 4.00 3.500 2.00 12.63 2.00

2.00

24

3.69 3.69 1.28 4.00 3.38 3.50 3.19 5.00 12.13 8.50 19.31 22.81

5.500 4.00 3.500 2.00 12.63 2.00

2.00

24

3.69 3.69 1.28 4.00 3.38 3.50 3.19 5.00 12.13 8.50 19.31 22.81

1 (std.) 5.500 4.50 4.000 2.25 14.88 2.50

2.50

24

4.44 4.44 1.41 4.50 3.88 4.00 3.19 5.38 14.50 10.13 22.19 26.19

8.000 4.50 4.000 2.25 14.88 2.50

2.50

24

4.44 4.44 1.41 4.50 3.88 4.00 4.00 6.19 14.50 10.13 23.00 27.00

7.000 4.50 4.000 2.25 14.88 2.50

2.50

24

4.44 4.44 1.41 4.50 3.88 4.00 3.50 5.69 14.50 10.13 22.50 26.50

1 (std.) 7.000 6.00 5.000 3.00 17.13 2.50

2.50

24

4.88 4.88 1.41 5.75 4.19 5.00 3.50 5.88 15.63 10.88 24.88 29.88

10.000 6.00 5.000 3.00 17.13 2.50

2.50

24

4.88 4.88 1.41 5.75 4.19 5.00 4.50 6.88 15.63 10.88 25.88 30.88

8.000 6.00 5.000 3.00 17.13 2.50

1 (std.) 8.000 7.00 6.000 3.50 19.00


16.00

NPTF1 SAE
SAE
Flange Straight
Port2 Thread
Port3

2.50

24

4.88 4.88 1.41 5.75 4.19 5.00 4.00 6.38 15.63 10.88 25.38 30.38

3.00

24

5.88 5.88 1.91 7.00 6.25 6.00 4.00 7.00 18.13 12.13 29.13 35.13
5.88 5.88 1.91 7.00 6.25 6.00 4.25 7.25 18.13 12.13 29.38 35.38

9.000 7.00 6.000 3.50 19.00

3.00

24

10.000 7.00 6.000 3.50 19.00

3.00

24

5.88 5.88 1.91 7.00 6.25 6.00 4.50 7.50 18.13 12.13 29.63 35.63

1 (std.) 9.000 8.00 6.500 4.00 22.00

3.00

24

6.88 6.88 1.91 7.63 6.75 6.50 4.25 7.25 21.13 15.13 33.00 39.50

10.000 8.00 6.500 4.00 22.00

3.00

24

6.88 6.88 1.91 7.63 6.75 6.50 4.50 7.50 21.13 15.13 33.25 39.75

20.00 1 (std.) 10.000 9.00 7.500 4.50 24.00

3.00

24

7.88 7.88 1.91 8.75 7.75 7.50 4.50 7.50 23.63 17.63 36.88 44.38

18.00

NPTF ports are available at no extra charge.


2
Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1

Table 2 Optional SAE Flange Port Pattern


A DIA.

Q
W
HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

X
GG

Nom.
Q
A
GG
Flange
Size
2
2.00 3.062 1.688
2 1/2 2.50 3.500 2.000
3
3.00 4.188 2.438

Z-THD
UNC2B
1.53 0.84 1/2-13
1.75 1.00 1/2-13
2.09 1.22 5/8-11
W

AA SAE
Min.
1.06
1.19
1.19

32
40
48

60
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Head Trunnion Mounting
Style D
(NFPA Style MT1)

WF

UT
1

ZB + STROKE
P + STROKE
LG + STROKE
EE

.125R MAX.
4
E
SQ.TD

MM

3
TL

TL

XG

Table 1 Dimensional and Mounting Data


Bore

Rod
No.

MM
Rod

Ports (EE)
NPTF1

SAE
SAE
Flange Straight
Port2 Thread
Port3

1 (std.) 4.500 12.63 2.00


2
7.000 12.63 2.00
10.00
3
5.000 12.63 2.00
4
5.500 12.63 2.00
1 (std.) 5.500 14.88 2.50
2
8.000 14.88 2.50
12.00
3
7.000 14.88 2.50
1 (std.) 7.000 17.13 2.50
14.00
2
10.000 17.13 2.50
3
8.000 17.13 2.50

TD
+.000
-.001

TL

UT

WF

XG

Add Stroke
LG
P
ZB
Max.

2.00

24

3.69 3.69 1.28 3.500 3.50 19.63 2.94 4.75 4.75 12.13 8.50 16.69

2.00
2.00

24
24

3.69 3.69 1.28 3.500 3.50 19.63 3.50 5.31 5.31 12.13 8.50 17.25
3.69 3.69 1.28 3.500 3.50 19.63 3.19 5.00 5.00 12.13 8.50 16.94

2.00
2.50

24
24

3.69 3.69 1.28 3.500 3.50 19.63 3.19 5.00 5.00 12.13 8.50 16.94
4.44 4.44 1.41 4.000 4.00 22.88 3.19 5.38 5.38 14.50 10.13 19.44

2.50
2.50

24
24

4.44 4.44 1.41 4.000 4.00 22.88 4.00 6.19 6.19 14.50 10.13 20.25
4.44 4.44 1.41 4.000 4.00 22.88 3.50 5.69 5.69 14.50 10.13 19.75

2.50
2.50

24
24

4.88 4.88 1.41 4.500 4.50 26.13 3.50 5.94 5.88 15.63 10.88 20.88
4.88 4.88 1.41 4.500 4.50 26.13 4.50 6.94 6.88 15.63 10.88 21.88

2.50

24

4.88 4.88 1.41 4.500 4.50 26.13 4.00 6.44 6.38 15.63 10.88 21.38

NPTF ports are available at no extra charge.


Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1
2

Table 3 Maximum Operating Pressure D Mount

Table 2 Optional SAE Flange Port Pattern


A DIA.

Bore

psi

10.00
12.00
14.00

2800
2350
2200

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Nom.
Q
GG
W
X
A
Flange
Size
2
2.00 3.062 1.688 1.53 0.84
2 1/2 2.50 3.500 2.000 1.75 1.00

Z-THD
UNC2B
1/2-13
1/2-13

AA SAE
Min.
1.06
1.19

32
40

61
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Cap Trunnion Mounting
Style DB
(NFPA Style MT2)

WF

UT
1

ZB + STROKE
P + STROKE
LG + STROKE
EE

.125R MAX.
4
E
SQ.TD

MM

3
TL

TL

XJ

Table 1 Dimensional and Mounting Data


Bore

10.00

12.00

14.00

Rod
No.

MM
Rod

Ports (EE)
NPTF

1 (std.) 4.500 12.63


2
7.000 12.63

SAE
SAE
Flange Straight
Port2 Thread
Port3

TD
+.000
-.001

TL

UT

WF

Add Stroke
LG

XJ

ZB
Max.

2.00

2.00

24

3.69 3.69 1.28 3.500 3.50 19.63 2.94 4.75 12.13 8.50 13.38 16.69

2.00

2.00

24

3.69 3.69 1.28 3.500 3.50 19.63 3.50 5.31 12.13 8.50 13.94 17.25

5.000 12.63

2.00

2.00

24

3.69 3.69 1.28 3.500 3.50 19.63 3.19 5.00 12.13 8.50 13.63 16.94

5.500 12.63

2.00

2.00

24

3.69 3.69 1.28 3.500 3.50 19.63 3.19 5.00 12.13 8.50 13.63 16.94

1 (std.) 5.500 14.88

2.50

2.50

24

4.44 4.44 1.41 4.000 4.00 22.88 3.19 5.38 14.50 10.13 15.50 19.44

8.000 14.88

2.50

2.50

24

4.44 4.44 1.41 4.000 4.00 22.88 4.00 6.19 14.50 10.13 16.31 20.25

7.000 14.88

2.50

2.50

24

4.44 4.44 1.41 4.000 4.00 22.88 3.50 5.69 14.50 10.13 15.81 19.75

1 (std.) 7.000 17.13

2.50

2.50

24

4.88 4.88 1.41 4.500 4.50 26.13 3.50 5.88 15.63 10.88 16.69 20.88

2.50

2.50

24

4.88 4.88 1.41 4.500 4.50 26.13 4.50 6.88 15.63 10.88 17.69 21.88

2.50

2.50

24

4.88 4.88 1.41 4.500 4.50 26.13 4.00 6.38 15.63 10.88 17.19 21.38

2
3

10.000 17.13
8.000 17.13

NPTF ports are available at no extra charge.


2
Optional SAE flange ports may be specified flange to be supplied by customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.
1

Table 3 Maximum Operating Pressure DB Mount

Table 2 Optional SAE Flange Port Pattern


A DIA.

Bore

psi

10.00
12.00
14.00

2800
2350
2200

X
GG

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Nom.
Q
X
A
GG W
Flange
Size
2
2.00 3.062 1.688 1.53 0.84
2 1/2 2.50 3.500 2.000 1.75 1.00

Z-THD
UNC2B
1/2-13
1/2-13

AA SAE
Min.
1.06
1.19

32
40

62
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Mounting Information Large Bore


Intermediate Fixed Trunnion Mounting
Style DD
(NFPA Style MT4)

WF

UM

ZB + STROKE
P+ STROKE
LG+ STROKE
EE

1
.125R MAX.

T Y TD

2 E
MM
SQ. UW

TL

TM

G
5
XI

TL

BD

Table 1 Dimensional and Mounting Data


Bore Rod
No.

10.00

12.00

14.00

16.00
18.00
20.00

MM
Rod

1 (std.) 4.500
2
7.000
3
5.000
4
5.500
1 (std.) 5.500
2
8.000
3
7.000
1(std.) 7.000
2 10.000
3
8.000
1(std.) 8.000
3
9.000
4 10.000
1(std.) 9.000
3 10.000
1(std.) 10.000

EE Ports

BD

NPTF SAE SAE


Flge. Str.
Port2 Thr.
Port3
1

12.63
12.63
12.63
12.63
14.88
14.88
14.88
17.13
17.13
17.13
19.00
19.00
19.00
22.00
22.00
24.00

2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
4
4
4
4
4
4

2.00
2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
3.00
3.00
3.00
3.00
3.00
3.00

24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

4.50
4.50
4.50
4.50
5.50
5.50
5.50
5.50
5.50
5.50
4
4
4
4
4
4

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

3.69
3.69
3.69
3.69
4.44
4.44
4.44
4.88
4.88
4.88
5.88
5.88
5.88
6.88
6.88
7.88

1.28
1.28
1.28
1.28
1.41
1.41
1.41
1.41
1.41
1.41
1.91
1.91
1.91
1.91
1.91
1.91

TD TL
+.000
-.001

TY

UM

UW

3.500
3.500
3.500
3.500
4.000
4.000
4.000
4.500
4.500
4.500

3.50
3.50
3.50
3.50
4.00
4.00
4.00
4.50
4.50
4.50

14.00
14.00
14.00
14.00
16.50
16.50
16.50
19.50
19.50
19.50

13.00
13.00
13.00
13.00
15.50
15.50
15.50
19.25
19.25
19.25

21.00
21.00
21.00
21.00
24.50
24.50
24.50
28.50
28.50
28.50

17.50
17.50
17.50
17.50
20.75
20.75
20.75
24.75
24.75
24.75

NPTF ports are available at no extra charge.

Optional SAE flange ports may be specified flange to be supplied by


customer. See Table 2 for flange port pattern dimensions.
3
SAE straight thread ports are standard and are indicated by port number.

WF Min.
XI5

2.94
3.50
3.19
3.19
3.19
4.00
3.50
3.50
4.50
4.00
4.00
4.25
4.50
4.25
4.50
4.50

9.06
9.63
9.31
9.31
10.63
11.50
10.94
11.44
12.44
11.94
4
4
4
4
4
4

4.75
5.31
5.00
5.00
5.38
6.19
5.69
5.88
6.88
6.38
7.00
7.25
7.50
7.25
7.50
7.50

Add Stroke
LG

ZB
Max.

12.13
12.13
12.13
12.13
14.50
14.50
14.50
15.63
15.63
15.63
18.13
18.13
18.13
21.13
21.13
23.63

8.50
8.50
8.50
8.50
10.13
10.13
10.13
10.88
10.88
10.88
12.13
12.13
12.13
15.13
15.13
17.63

16.69
17.25
16.94
16.94
19.44
20.25
19.75
20.88
21.88
21.38
24.38
24.63
24.88
27.63
27.88
30.38

Consult Factory
Dimension XI to be specified by customer.

Table 3 Maximum Operating Pressure DD Mount

Table 2 Optional SAE Flange Port Pattern


A DIA.

Bore

psi

10.00
12.00
14.00

2800
2350
2200

X
GG

TM

HEAD
OR CAP
Z-4 HOLES
FULL THREAD
DEPTH AA

Nom.
A
Q
GG
W
X Z-THD
Flange
UNCSize
2B
2
2.00 3.062 1.688 1.53 0.84 1/2-13
2 1/2 2.50 3.500 2.000 1.75 1.00 1/2-13
3
3.00 4.188 2.438 2.09 1.22 5/8-11

AA SAE
Min.
1.06
1.19
1.19

32
40
48

63
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Heavy Duty Hydraulic Cylinders


Series 3H

Catalog HY08-1114-1/NA

Double Rod Models Large Bore


Double Rod Cylinder
Style K

ZM + 2 x STROKE
ZB + STROKE
Y

P + STROKE
LG + STROKE

WF

EE

MM

Rod End #1 SW
XS

Mounting Styles
Mounting Styles
for Single Rod
for Corresponding
Models
Double Rod Models1
TB
TD
JJ
JB
C
D
DD2

KTB
KTD
KJJ
KJB
KC
KD
KDD

SU

SU

SS + STROKE

Dimension Shown on
This Page Supplement
Dimensions on Pages
Listed Below
53
53
54/55
56
59
61
63

Bore

10.00

12.00

1
If only one end of these Double Rod Cylinders is to be cushioned, be
sure to specify clearly which end this will be.
2
Specify XI dimension from rod end #1.

14.00

16.00
18.00
20.00

K
SW

Rod End #2

Rod
Code

Rod

1
2
3
4
1
2
3
1
2
3
1
3
4
1
3
1

4.500
7.000
5.000
5.500
5.500
8.000
7.000
7.000
10.000
8.000
8.000
9.000
10.000
9.000
10.000
10.000

Add 2X
Stroke
ZM
18.00
19.12
18.50
18.50
20.88
22.50
21.50
22.63
24.63
23.63
26.13
26.63
27.13
29.63
30.13
32.63

How to Use Double Rod Cylinder


Dimension Drawings
additional information needed to completely dimension a
double rod cylinder model.

To obtain dimensioning information on a double rod cylinder,


first select the desired mounting style and refer to the
corresponding single rod cylinder model shown on the
preceding pages. (See table above.) After you have
determined all necessary dimensions from that drawing, turn
back to this page and supplement those dimensions with
additional ones from the drawing above and table at right.
These added dimensions differ from, or are in addition to,
those shown on the preceding pages and provide the

On a double rod cylinder where the two rod ends are different,
be sure to clearly state which rod end is to be assembled at
which end. Port position 1 is standard. If other than standard,
specify pos. 2, 3 or 4 when viewed from rod end #1 only. See
port position information in Section E.

64
www.parker.com/cylinder

Parker Hannifin Corporation


Cylinder Division
Des Plaines, Illinois USA

Вам также может понравиться