Вы находитесь на странице: 1из 78

Geberit HDPE Installati 1.12.

03

1/12/03

2:45 pm

Page 1

Geberit HDPE

B.600.000/020

TYP 84 A MEDI H. NR. MASC

Installation Guide

A D V A N C E D
90 0 50 11 63 75 5 12 0 16

P L U M B I N G

T E C H N O L O G Y

Geberit HDPE Installati 1.12.03

1/12/03

2:45 pm

Page 2

Converting tables

Converting table InchMillimeter Inch mm


3 8" 1 " 2 3 " 4

1"

114" 112" 2"

212"

3" 63,5

4" 76,2 101,6 90 83 110 125

5" 127

6" 152,4 160 200

8"

10"

9,5 12,7 19

25,4 31,8 38,1 50,8 32 26 40 34 50 44 56 50 63 57

203,2 254 250 315

Geberit outside Geberit inside

75 69

101,4 115,2

147,6 187,6 234,4 295,4

Temperature scales

Pressure scale 212 194 176 158 140 122 104 95 86 77 68 59 50 41 32 23 14 5 0 4 13 22

100 90 80 70 60 50 40 35 30 25 20 15 10 5 0 5 10 15 17,8 20 25 30

1 bar = 1000 mbar 1 bar = 100 000 Pa (=


N m2 )

1 bar = 10,2 m Water column 1 bar = 14,5 psi 1 psi = 6896.43


N m2

1 psi = 1 lb/square inch

Length scale 1 m = 1000 mm 1 m = 100 cm 1m = 10 dm

1 cm = 10 mm 1 dm = 10 cm = 100 mm

To convert Centigrade to Fahrenheit: Multiply Centigrade by 1,8 and add 32. F = (C x 1,8) + 32 To convert Fahrenheit to Centigrade: Subtract 32 from Fahrenheit and divide by 1,8. C = (F 32) : 1,8

Geberit HDPE Installati 1.12.03

1/12/03

2:45 pm

Page 3

Summary

Geberit HDPE overview Drainage system Application field for pipes and fittings HDPE pipes, fittings and tools Jointing methods Water proofing Thermal movement Accomodating thermal movement Deflection leg Expansion socket Anchor brackets and guide brackets Installation examples Prevention of thermal movement Rigid installation Brackets, embedded fixed points Mounting instructions Butt welding Electro welding Prefabrication Repair tool Expansion sockets Special application fields Underground drainage Pipe penetration through building walls Connection to manhole Drainage of bridges Low pressure installation External and internal pressure Fire protection Geberit HDPE characteristics Physical characteristics Ecological properties Comments on individual properties Tempering (Geberit Licence) pH Value Chemical resistance list Normes/Certificates

page 3 4 5 7 817 18 1920

21 22 2325 2629

30 3132

3335 3638 3941 42 43

4448 49 50 5152 53 54 5556

57 5859 6062 63 64 6575 77

Geberit HDPE Installati 1.12.03

1/12/03

2:45 pm

Page 4

Drainage-System

5 6 4 3 2 6

8 7

1 Ground pipe 2 Main stack 3 Branch pipe 4 Connector pipe 5 Ventilation stack 6 Rainwater down pipe 7 Domestic drainage 8 Public sewer

Geberit HDPE Installati 1.12.03

1/12/03

2:45 pm

Page 5

Application field for Geberit HDPE pipes and fittings

Description Pipe Bend 45 Bend 8812 Bend 90 Branch 45 Branch 8812 Ball fittings Reducer Apparatus connections Butt welded joints Electroweld sleeve coupling/flange Expansion socket Ring seal socket Flange bushing Double flange bushing Access pipe X

Symbol

House drainage X X X X X X X X X X X X X X X X

Underground Bridge drainage drainage X X X X X X X X X X X X X X X X X X X X X X X

Pressure load X X X X X X X X X X

Pluvia X X X X X X X X X X X X

=Applicable =Not applicable =For horizontal installation max. 110

Geberit HDPE Installati 1.12.03

1/12/03

2:45 pm

Page 6

Geberit HDPE pipes

d di A cm2 s

5m

HDPE pipes Nominal (Outside) dia. d (mm) 32 40 50 56 63 75 90 110 125 160 200 250 315 Wall thickness s (mm) 3 3 3 3 3 3 3,5 4,3 4,9 6,2 6,2 7,8 9,8 Inside dia. di (mm) 26 34 44 50 57 69 83 101,4 115,2 147,6 187,6 234,4 295,4 Area A (cm2) 5,3 9,0 15,2 19,6 25,4 37,3 54,1 80,7 104,5 171,1 276,4 431,5 685,3 Weight empty kg/m 0,259 0,331 0,420 0,471 0,536 0,644 0,903 1,350 1,750 2,840 3,580 5,630 8,920 Weight full kg/m 0,790 1,239 1,940 2.434 3,087 4,383 6,313 9,424 12,171 19,947 31,216 48,774 77,442 Pressure* nominal PN 10 6 6 6 4 4 4 4 4 4 3,2 3,2 3,2 Series (ISO) S 5 6,3 8,3 10 12,5 12,5 12,5 12,5 12.5 16 16 16

Art. No. 379.000.16.0 360.000.16.0 361.000.16.0 363.000.16.0 364.000.16.0 365.000.16.0 366.000.16.0 367.000.16.0 368.000.16.0 369.000.16.0 370.000.16.0 371.000.16.0 372.000.16.0

Standard length of Geberit HDPE pipes = 5 meters (5000 mm) * = Nominal pressure refers to pipe only not to fittings ISO = International Standard Organisation

Standards

International European Switzerland Germany Austria France Italy Belgium Netherlands Denmark Great Britain

ISO 8770 / 8772 CEN / TC 155 (in preparation) SN 592 012 DIN 8075 / 19535 / 19537 B 5177 NF T 54 072 UNI 8451 NBN 42-112 NEN 7008 NKB Nr. 8 BS /6367/5572/6437/5114

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 7

Geberit HDPE fittings

HDPE fittings

Silent fittings and pipes

Prefabricated or conventional installation.

Pipeline embedded in concrete.

Underground drainage pipes.

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 8

Geberit Tools

Pipe Cutter

Hand Mitre Saw

Welding Plate

Repair Tool

B.356.176/001
B.356.220/001

Electrofusion Machine

Start Switch

TYP 84 MEDIA H. NR.

MASC

Welding Machine MEDIA

Welding Machine UNIVERSAL

" te "BARY appara hweiss toff-Sc Kunsts AType: Volt 230 iz) Watt (Schwe Nr. en Basel 45 rasse W.Ries Dittingerst
90 50 110 63 75 125 160

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 9

Geberit HDPE jointing methods Overview

The many Geberit jointing methods offer solutions for all situations.

Butt weld

Electroweld sleeve coupling

Ring-seal socket

Screw-threaded joint

Linear expansion socket

Flange joint

These connections have different properties, and are therefore classified according to the way in which they are assembled as follows: a) Non-rigid, removable Connections which can be disconnected after assembly. b) Rigid, non removable Connections which cannot be disconnected after assembly. c) Tension-resistant Connections which cannot be disconnected by tensional forces. (Butt weld, electroweld sleeve, flange, screwed connection with locking ring) d) Non-tension-resistant Connections which can be disconnected by tensional forces. (Ring-seal socket, expansion socket, screw-threaded joint)

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 10

Butt welding

All diameters from 32 to 315 mm can be welded. Connection properties b) rigid, non removable c) tension-resistant Use Welding is the easiest jointing method, providing the many advantageous benefits of prefabrication; HDPE needs no other component in order to be welded. It can be used in all circumstances where prefabrication is used on site or in the workshop. The essential conditions for a perfect weld are: Cleanliness of the welding plate and the parts which are to be welded. A correct welding plate temperature. A simple and reliable connection The correct pressure for jointing the parts. The parts to be welded must be cut square < 90. ) Butt welding takes up little space. The edge of the weld does not obstruct the pipe, leaving its internal cross-section virtually unchanged. Even quite complicated distribution parts can be assembled in a small space, without wastage of material, because lengths of pipe or elbow sections can be easily reused through butt welding. Allowance for butt welds The allowance for butt welds is approx. as big as the wall thickness of the pipe pipe diameter (mm) butt weld s (mm) Indicative values of operating pressure
Warming-up and welding times 5 4 3 2 1 0 2 4 6 8 10 12 Pipe wall thickness in mm
e tim

3275 3

90 4

110 5

125 5

160 7

200 7

250 8

315 10

Welding time in min.

ing e eld tim W -up ing rm Wa

Guide values for welding pressure 32

kg 5 6 7 8 9 10 15 22 28 45 57 90 140

Manual welding up to 75 mm

Machine welding from 40 315 mm

40 50 56 63 75 90 110 125 160 200 250 315

90 0 50 11 63 75

5 12 16 0

TYP 84 IA MED CH. NR. MAS

10

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 11

Electroweld sleeve coupling

Available from 40 to 315 mm. Connection properties b) rigid, non removable c) tension-resistant Use On-site welding, conversion, additional installations, repairs. The small outside diameter provides a great advantage. Conventional assembly, on the nesting principle, made for easy use. The joint obtained is simple, quick and reliable. A short, simple and reliable connection The heating and melting zone is divided into two fields, as there are no electrical resistances in the centre of the sleeve. This provides a very satisfactory safety factor. Also the ends of the pipes are not heated, the zones remain effectively cold, and provide further reinforcement, thus cancelling out shrinkage of the pipe. The pressure required for welding is obtained from the shrinking effect of the sleeve when it is heated, and is evenly distributed over the entire weld. This shrinkage has a compensating effect on pipe diameter measurement tolerances. The electrical resistance wires will not corrode. Once the weld has been made they are entirely covered by PE. The use of original Geberit equipement, especially tempered Geberit HDPE pipes, are recommended for correct welding. Electrical sleeves can be made to slide by removing the central stop ring, thus making system conversion and repair work easier. 150

60

40 160

200 315

B.500.000/191

B.500.000/192

3 cm 3 cm

The stop ring can easily be removed with a screwdriver.

11

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 12

Ring-seal socket joint

Available from 32 to 160 mm. Connection properties a) non-rigid, removable d) non-tension-resistant Use Ring-seal socket joints can be used to provide a connection between various prefabricated parts for simpler assembly. Assembly May be used either vertically or horizontally. The small overall dimensions provide an advantage where space is limited. Can easily be assembled or released even where access is difficult. Ring-seal sockets are provided with a yellow protection cap to prevent the ingress of debris during installation.

Protection cap

Assembly instructions are the same for both ring-seal sockets and screw-threaded joints, the sleeve lengths are the same for corresponding diameters. The effective sleeve length, i. e. the measurement X from the O-ring to the base of the socket governs the maximum length of pipe which can be connected by individual joints. For HDPE approximately 15 mm of spigot should be allowed for every 1 m of pipe. The pipe must be fully inserted into the socket, because the socket does not act as an expander. Owing to the pipe thickness and the low thermal conductivity of HDPE, the socket seal has very satisfactory resistance to heat and no shrinkage of the O-ring occurs. The O-ring has a round seat regardless of pipe movements. The O-ring remains fixed in the seat and is always in contact with the pipe.

x
Length X varies with the diameter

Ideal fitting is obtained by chamfering the pipe end to approximately 15, lubricating it with soft soap, Silicone or Vaseline. Do not use mineral oil or grease which can damage the rubber seal.

12

B.500.000/252

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 13

Screw-threaded joint

Available from 32 to 110 mm. Connection properties a) non-rigid, removable d) non-tension-resistant Use Screw-threaded joints are used for assembly of various prefabricated parts when it is necessary to easily dismantle and also as the connection to sink traps and shower trays.

B.360.740/001

1 2 3 4
Complete screw-threaded joint

The seal is pressed against the thread. 1 2 3 4 A minimum surface area of the seal is in contact with water.

1. 2. 3. 4.

Nut Washer Seal Thread Available from 32 to 110 mm. Connection properties a) non-rigid, removable c) tension-resistant Use Wherever there is the possibility that a pipe can be pulled out of a screw-threaded joint by axial tensile forces a flange bushing must be used to ensure that the connection will resist these forces. It is also recommended that a screw-threaded joint with flange bushing should be used when installing in floors or slabs, where the length of pipe between two connections (elbows, branches or sleeves) is longer than 2 metres. 1 The seal is pressed against the flange bushing and the thread. 1 2 4 3

Screw-threaded joint with flange bushing

2 3

1. 2. 3. 4.

Nut Flange bushing Seal Thread

13

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 14

Expansion socket

Available from 32 to 315 mm. Connection properties a) non-rigid, removable d) non-tension-resistant Use An expansion socket is recommended between anchor brackets, particularly on installations assembled with rigid joints and where excessive thermal movement is anticipated. At least one expansion joint must be provided on vertical stacks running from floor to floor, long collector pipelines and before connecting to the buried drain pipework. Different conditions apply for underground installations. For this application field see page 48. Installation Can be used either vertically or horizontally. One advantage is the depth of the sleeve which makes the assembly of downpipes and mains easier, allowing both vertical and horizontal corrections (e.g. in level, and in the precise positioning of the direction of branches and elbows). A firm anchor bracket must always be located behind the expansion socket to avoid any movement of the socket in the event of expansion or contraction. The special shape of the seal allows the pipe to slide within the socket during expansion and contraction, ensuring that the connection remains perfectly watertight even under heavy hydraulic load.
Horizontal assembly (e.g. at 20C)

Example: Insertion depth in an ambient temperature of 20C (Vertical assembly).

The following conditions are important to ensure perfect and easy assembly of the sleeve: 1. Chamfering the inserted pipe end to approximate <15. ) 2. Check the scale on the outer surface of the expansion socket for insertion depth. 3. Mark the correct insertion depth on the pipe. 4. Lubricate the pipe end well with soft soap, Silicone or Vaseline. N.B. Do not use oil or grease which can damage the rubber seal. For more information see pages 22, 28, 43. A special expansion socket with stainless steel protection for the rubber seal can be used for heavy duty industrial and laboratory applications.

14

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 15

Flanged joint

Available from 50 to 315 mm. Connection properties a) rigid, removable c) tension-resistant Use Flanges are normally used as disconnectable joints for low pressure installations (industrial plant, pump connection, tanks and swimming pools). The flange connection system offers easy connection to existing iron and steel installations. As inspection access opening made by using a blind flange. Flanges are sintered, i.e. they are coated with polyethylene, and have standard dimensions (PN 10 and 16).

Bolts Loose flange, PE coated

Flange adaptor Seal Flange adaptor Loose flange Nuts

Loose flange Nut and bolt Seal Flange adaptor Blind flange

15

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 16

Jointing Geberit HDPE to other materials

Geberit to steel / Cast iron


Geberit / Cast iron
A Geberit HDPE pipe 50 315 mm D Geberit Adaptor piece with stainless steel insert C Pipe clip local available B Cast iron pipe steel pipe 60 300 mm

A Geberit HDPE

outside mm 50 56 63 75 75 90 110 125 160 200 250 315

B Cast iron

outside mm 68 68 68 68 89 89 109 135 161 212 274 326

C Local

D H

available

mm 78 78 100 78 80 100 100 100 100 160 160 160

Art. No. 359.260.16.1 359.262.16.1 359.263.16.1 359.264.16.1 359.265.16.1 359.266.16.1 359.267.16.1 359.268.16.1 359.261.16.1 370.738.16.1 371.738.16.1 372.738.16.1

Geberit to clay / Fibre cement

A Geberit HDPE pipe

A Geberit outside mm 110 125 160 200 250 315

B Vitrified clay DN mm 100 120 150 200 250 300

X mm 146 169 202 259 315 369

H mm 150 150 150 200 200 200

C Geberit Art. No. 367.739.16.1 368.739.16.1 369.739.16.1 370.739.16.1 371.739.16.1 372.739.16.1

45 X

C Rubber sealing gasket

B Clay pipe fibre cement

Important:
The joint is made with a coupling from HDPE to steel, cast iron or earthenware and secured with an anchor bracket. Install the anchor bracket as close as possible to the coupling. (Maximum 15 mm)

1 Anchor bracket 2 Butt weld seam 3 Coupling 4 PE adaptor with support ring 5 Steel, cast iron, clay, fibre cement pipes

16

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 17

Geberit HDPE contraction sleeve

Available from 50 to 315 mm Connection properties b) rigid, non-removable d) non-tension-resistant Use The Geberit HDPE contraction sleeve is a convenient connection possibility for most uneven, irregular or special materials. A common additional application method is also the connection from HDPE to different clay ware apparatus, e. g. for Laboratory sinks. Installation The enclosed rubber ring will be placed over the pipe end. Make sure that the rubber ring will be placed in the middle of the sleeve length (h2). Then push the contraction sleeve over the pipe end. Apply low heat (approx. 125C) evenly around the socket, moving the blow lamp constantly. The sleeve will now shrink and give an absolute watertight and strong connection. Afterwards fix the contraction sleeve pipe with an anchor bracket.

approx. 125C

Laboratory sink

Geberit contraction sleeve Anchor bracket

B.500.000/069

pipe end ring seal rubber ring Geberit HDPE contraction sleeve

For 125315 mm use two soft flames.

Contraction sleeve with seal


di AB

h1 H

h K d

d di (mm) 50/ 60 73 80 90 100 56/ 60 73 80 63/ 73 80 90 75/ 80 90 100 90/110 110/125 140 125/150 160/195 230

H (cm) 30 27,5 28,5 30,5 31 26,5 24,5 24,5 26,5 24,5 26,5 25 24,5 15 17 16 18 18 20 30

h (cm) 24 22 23 23,5 24 20,5 19 19 20,5 19 19,5 19 17,5 8 7 6 8 8 8 14

h1 (cm) 6 5,5 5,5 7 7 6 5,5 5,5 6 5,5 7 6 7 7 10 10 10 10 12 18

K (cm) 17 17 17 17 17 14 14 14 14 14 14 12 12 12 2,5 1 1 5

for (mm) 53 54 60 67 67 74 80 84 90 94 53 54 60 67 67 74 60 67 67 74 80 84 67 74 80 84 90 94 84 98 102111 102126 116136 148180 189212

Art. No. 152.651.16.1 152.197.16.1 152.198.16.1 152.652.16.1 152.653.16.1 152.654.16.1 152.149.16.1 152.150.16.1 152.657.16.1 152.658.16.1 152.659.16.1 152.152.16.1 152.151.16.1 152.661.16.1 366.550.16.1 367.551.16.1 367.550.16.1 368.550.16.1 369.550.16.1 369.551.16.1

200315 available on request

17

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 18

Geberit HDPE Adaptors

Pipe threads (for detail information see HDPE catalogue, p. 47)


Connection to: Male pipe thread Thread dia.
1 "21 " 2 2

Geberit dia. 4075 mm

Material HDPE with steel ring reinforcement

Female pipe thread 114"212"

50 75 mm

HDPE with steel ring reinforcement

Female pipe thread 112"2"

50 + 56 mm

Adaptor in brass + PE nut

Male pipe thread

2" 3"

56 + 75 mm

Adaptor in brass + PE nut

Threaded pip ends (for detail information see HDPE catalogue, p. 21)
Connection to: Male-thread Thread dia. 114"2" Geberit dia. 3250 mm Material HDPE, upon request also available with nut in brass

Male-thread

60 x 18"

40 + 50 mm

HDPE

Female-thread

1 "1" 2

40 + 50 mm

HDPE, with brass nipple

Soldering / Welding (for detail information see HDPE catalogue, p. 48)


Connection to: Pipe dia. Geberit dia. Material

Lead

50/60

56 mm

Brass with PE nut for soldering

Lead

50/60

56 mm

Lead with PE nut for welding or soldering PVC for solvent cement joint + PE nut

PVC

50 + 63

56 mm

18

Geberit HDPE Installati 1.12.03

1/12/03

2:46 pm

Page 19

Water proofing

Wherever a water proof layer is required, the Geberit sealing for passages through walls or ceilings provides a perfect watertight seal between the HDPE pipe and the water proof membrane. 50 cm Type 1: Resistit for connection with bitumn Type 2: PVC to be welded with PVC sheet Type 3: PE to be welded with Sarnafil FPO-A-foil For Geberit HDPE pipes 50, 56, 75, 110, 125 mm

50 cm

Attention: Thermal expansion or contraction of the pipe is to be prevented. Maximum water pressure 0,1 bar.

Installation examples
Pipe Sealing

Waterproofing membrane Electroweld sleeve coupling (to prevent expansion or contraction) Expansion socket Anchor Bracket Reducer

Waterproofing membrane

Access pipe

Sealing Waterproofing membrane

19

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 20

Thermal movement

Physical principal: All materials expand as temperature increase. If the temperature falls, the material contracts.

Geberit HDPE Expansion Coefficient

0,2

mm mK

Rule of thumb: t 50 = 10 mm/m

30C

1000 mm

5000 mm

80C

1010 mm

5050 mm

0C

994 mm

4970 mm

Length Variation Table


Pipe length

Example: 1. Sought: Thermal expansion L 2. Given: Maximum temperature = 80C Installation temperature = 20C Temperature difference t = 60C Pipe length 3. Result: Thermal expansion L =4m = 4,8 cm = 48 mm

Temperature difference t in C

Determination of thermal expansion of HDPE (average linear expansion coefficient 0,2 mm/m K)

Length alteration (L) of the expansion leg

[cm]

20

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 21

Thermal movement

There are alternative methods of installing the Geberit HDPE Drainage System.

Factors that will influence thermal movement

Methods of accomodating thermal expansion and contraction

Prevention of thermal expansion and contraction

Deflection Leg

Expansion Socket

Rigid Fastening

Installation Embedded in Concrete

21

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 22

Deflection leg

Compensating thermal expansion by deflection leg


+70C +20C 10C

+ 60

36

6000

DL

G Guide bracket A Anchor bracket DL Deflection leg

Determining the length of the deflection leg by calculation

Length of the deflection leg (DL) in mm according the formula

10 x L x

Example: DL = 10 x 60 x 110 = 820 DL = 10 x 36 x 110 = 630

B.500.000/294

B.500.000/294

Determining the length of the deflection leg from chart

20

Aussen- Outer-

32 40

50-63

75 90

110 125 140 160

200

250

315

18

16

Linear expansion or contraction L in cm

14
L des Dehnungsschenkels in cm

12

10

6
Lngennderung

Bestimmung des Determination of the deflection Biegeschenkels aus leg of HDPE

4,8 4

20

40

60

73 80

100

120

140

160

180

200

220

240

Lnge des Biegeschenkels in cm aus Formel BS ca. = xD Length of deflection leg DLBS incm. Formula= DL 10 xca.L10 x L x

22

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 23

Expansion socket

The Geberit expansion socket is designed to counteract the variation in length due to thermal expansion and contraction of max. 6 m Geberit HDPE pipes.

Application: Horizontally Vertically Diameter: 32 315 mm

Legend: Expansion socket: compensates the change of length Bracket: provides an anchor point Electroweld sleeve: holdes anchor bracket in position

Note: Each expansion socket needs to be fixed with 1 anchor bracket.

23

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 24

Anchor bracket for expansion socket

The main purpose of the anchor bracket is to prevent any movement of the expansion socket.

The distance L and the thrust forces P have to be taken in account, when selecting the diameter of the pipe nipple between mounting plate and bracket.

Thrust force 5063 75 90 110 125 160 200 250 315

P when in operation Thrust force P (kg) 10 12 20 30 40 70 100 150 220

The thrust force P is the slide resistance between rubber seal and HDPE pipe. This force depends on the pipe diameter.

The table beside shows the correct pipe nipple diameter required depending on distance L to effectively withstand thrust force P.

Diameters of Geberit HDPE pipe Distance from ceiling L (mm) 100 150 200 250 300 350 400 450 500 550 600 50/56/63/75/90 110 Pipe nipple used 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2
1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 3 " 4 3 " 4 3 " 4

125
1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 1 " 2 3 " 4 3 " 4 3 " 4 3 " 4

160
1 " 2 1 " 2 3 " 4 3 " 4

200
3 " 4

250 1" 1"


5 " 4 5 " 4 5 " 4 5 " 4

315

1" 1" 1" 1"


5 " 4 5 " 4 5 " 4 5 " 4

5 " 4 5 " 4

1" 1" 1" 1" 1" 1"

112" 112" 112" 2" 2" 2"

112" 112" 112"

1"

24

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 25

Guide brackets

The main purpose of guide brackets is to support the pipe and allow the axial movement caused by the effects of expansion and contraction. Application: For all fixations of Geberit HDPE pipes 40-315mm except for anchor brackets.

B.362.826/001

1 " 2

1 " 2

1 " 2

+
OR

Diameter 40 160 mm

B.362.837/001

M10

M10

M10

+
B.362.846/001

B.362.826/001

1"

1"

1"

Diameter 200 315 mm

1 " 2

1 " 2

B.362.826/001 1

2" Geberit PE-Silent 75 +110 mm

25

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 26

Spacing for brackets

Geberit HDPE pipes are to be fixed with anchor brackets (A) and guide brackets (G). The distance between the anchor bracket and the first guide bracket must be respected as follows:

Vertical installation:

Horizontal installation:

SA = max. 15 x

SA = max. 10 x
A SB SA A

A G SA SB

= = = =

Anchor Bracket Guide Bracket Spacing between anchor bracket and guide bracket Spacing between guide brackets (see table below)

SB max. 6 m G

Spacing of guide brackets SB: The table indicates the maximum distance between guide brackets (G) for Geberit HDPE pipes.
G SA max. 15 x A

Nominal outside diameter d (mm) 32 40 50 56 63 75 90 110 125 160 200 250 315

Spacing of brackets (SB) Horizontal (m) 0,5 0,5 0,8 0,8 0,8 0,8 1,0 1,5 1,5 1,5 2,0 3,0 3,0 Vertical (m) 1,2 1,2 1,2 1,5 1,5 1,5 2,0 2,0 2,0 2,0 2,0 3,0 3,0

26

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 27

A Examples of installing Geberit HDPE expansion socket

Principal: Every pipe installation exceeding a certain distance (6 meters) must be protected against mechanical load with an expansion socket.

Rainwater downpipe Rainwater downpipes are generally not subjected to large temperature changes except for those outside of buildings exposed to sunlight. In vertical pipelines the distance between the brackets can be calculated approx. as follows: 15 x pipe diameter (max. distance see p. 25)

A = Anchor bracket G = Guide bracket

27

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 28

B Examples of installing Geberit HDPE expansion socket

Stacks Not only does the HDPE expansion socket absorb thermal expansion and contraction due to temperature changes caused by water discharge, but it also makes pipe assembly easier, assisting connection at each floor level.

Rule:

One Geberit HDPE expansion socket at each floor level

1. Free-standing stack with branch

2. Stack with branch in concrete

Anchor point

G
A = Anchor bracket G = Guide bracket

A A

28

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 29

C Examples of installing Geberit HDPE expansion socket

Horizontal suspended collector pipeline When fitting collector pipelines that extend 6 m it is necessary to fit expansion sockets and secure them with anchor brackets (see p. 25). Between the anchor brackets, guide brackets must be installed at the distance SA or SB (see p. 25).

Rules: Maximum distance between Geberit HDPE expansion sockets 6 m Inserting depth depending on ambient temperature Anchor bracket directly on each Geberit HDPE expansion socket Guide brackets located along the collector pipeline (see page 25).

Example

max. 6 m

max. 6 m

max. 6 m

A = Anchor bracket G = Guide bracket

29

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 30

D Examples of installing Geberit HDPE expansion socket

Combination of stacks and collector pipelines

Rules: One Geberit HDPE expansion socket at each floor level One Geberit HDPE expansion socket at each branch One Geberit HDPE expansion socket at each change of direction Anchor bracket on each Geberit HDPE expansion socket.

Example

8,4 m

4,2 m

5,5 m

A
4,2 m

5,5 m

A A A
10 m 5m 5 8m

A = Anchor bracket G = Spacing between guide brackets in accordance to the rules (p. 25).

30

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 31

Rigid installation to control thermal expansion and contraction

Principal: Any variation in length must be prevented by embedded fixed points (electroweld sleeve couplings, branches, bends or collar bushes) or by the provision of corresponding fixed point structures.

Rigid installation with anchor brackets Anchor brackets for rigid fixings must be stronger than possible expansion or contraction forces (P) of the HDPE pipe (see table).

Expansion and contraction forces This table shows that in the low temperature range (column 2) the forces are greater than in the high temperature range (column 1).

Geberit HDPE pipe d 40 50 56 63 75 90 110 125 160 200 250 315

Ringsquare cm2 3,5 4,4 5,0 5,8 6,8 9,5 14 18,5 29,6 37,7 59,5 93,9

Column 1 (Normal installation) ca. + 20C bis + 90C force kg 85 105 125 140 170 240 350 460 740 940 1490 2350

Column 2 (Outside installation) ca. + 20C bis 20C force kg 221 277 315 365 428 598 882 1165 1865 2375 3750 5915

Example:

31

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 32

Anchor bracket for rigid installations

Rules: Anchor brackets must be stronger than the possible forces generated during thermal expansion or contraction of Geberit HDPE pipes.

Examples of anchor brackets

The examples of anchor brackets below show a typical rigid installation.

Anchor bracket with double electroweld sleeve coupling.

Anchor bracket with electrowelding tape.

Anchor bracket with flat iron and electrowelding tape.

Dimension of pipe nipple or flat iron profile The distance L and the thrust force P have to be taken in account, when selecting the diameter of the pipe nipple between mounting plate and bracket. For the required pipe nipple dimension see table beside.

Ceiling or wall distance L (mm) 100 150 200 250 300 350 400 450 500 550 600

Geberit-Dimensions 5056 6375 90 Pipe


1 " 2 3 " 4 3 " 4 3 " 4

110 1" 5 " 4 112" 112" 2" 2" 2" 2" 9,5 10,5 11,4 W cm3

125
5 " 4 5 " 4

160 W cm3 W cm3

1" 1"
5 " 4 5 " 4 5 " 4

1" 1" 1"


5 " 4 5 " 4 5 " 4

2" 2" 9,3 11,2 13,0 9,0 10,1 11,3 12,4 13,6 15,0 16,8 17,7 20,5 22,4

112" 2" 2" 2"

1" 1"
5 " 4 5 " 4 5 " 4 5 " 4 5 " 4

112" 112" 2" 2" 2" 2"

112" 112" 112" 112"

112"

W = indication coefficient for steel profile.

Mounting plates

These plates are dimensioned on the basis of stresses which they have to withstand (force P). Plates with 1" to 2" sockets can be provided on request.

100

32

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 33

Rigid installation to control thermal expansion and contraction

Principal: Any variation in length must be prevented by embedded fixed points in concrete (e. g. electroweld sleeve couplings, branches, bends or collar bushes) or by the provision of corresponding fixed point structures.

Embedding in concrete Basically Geberit HDPE material absorbs within itself thermal movement due to its high elasticity. However, in the case of large diameters (e.g. 315 mm) the forces P (resulting from expansion and contraction) are considerable. They must be absorbed by the embedded fixpoints alone, since cement/concrete will not adhere to HDPE pipework.

Since the fitting has to act as a fixpoint, do not insulate it.

Branch equal

Branch equal with reducer

Reduced small branches of large pipe diameters must be secured by an additional anchor point (electroweld sleeve couplings or collar bushes) to prevent shearing off of the branch.

Under no circumstances should a ring seal or expansion socket be embedded in concrete.

33

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 34

Geberit HDPE butt welding Preparation

Cut pipe properly with

Pipe Cutter

Hand Mitre Saw

32160 mm

200315 mm

Cut pipe square!

Cutting surface must stay clean, therefore do not touch the cutting surface with your hands!

Allowance for butt welds

The allowance for butt welds is approx. as big as the wall thickness of the pipe pipe diameter (mm) butt weld s (mm) 3275 3 90 4 110 5 125 5 160 7 200 7 250 8 315 10

34

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 35

Geberit HDPE butt welding by hand (for pipes 32 75 mm)


B.359.640/001

Indicative values for welding and warming-up times

Check temperature of the welding plate. Do not start with welding procedure before the green light is on.

Welding time in min.

5 4 3 2 1 0

e tim g in e eld tim W -up ing rm Wa

2 4 6 8 10 12 Pipe wall thickness in mm

2
Indicative values for welding pressure 32 40 50 56 63 75 kg 5 6 7 8 9 10

Only press the pipe sections at the beginning against the welding plate. Then hold without pressure. Watch melting process carefully.

3
Check visually the welding joint Correct

When melted bulge is about as big as a match head, take off both pipe sections simultaneously and quickly press them carefully together. Increase welding pressure until you attain necessary pressure (see scale beside).

False: out of axial alinement

4
Too high pressure at the start of the welding procedure Uneven welding heat

Maintain the max. pressure until the welding seam has cooled (approx. 30 secs.). Do not accelerate the cooling down by contact with cold objects or water.

35

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 36

Geberit HDPE butt welding by machine (for pipes 40 315 mm)

MEDIA 40 160 mm

Place pipe parts in the tension plates and fix them in a line.
1 cm 1 cm

90 50 110 63 75

125 160

UNIVERSAL 40 200 mm

Set of accessories 200 315 mm (for UNIVERSAL only)

90 50 110 63 75

125

TYP 84 A MEDI H. NR.

160

MASC

TYP 84 MEDIA H. NR.

MASC

Press pipe parts lightly against the planing disc and cut the ends until they are completly clean and plane. Check the cut faces by bringing them together.
90 0 50 11 63 75 5 12 0 16

TYP A 84 MEDI H. NR. MASC

Melt pipe ends with welding plate (green light on) until the melted bulge is about as big as a match head, depending on size of pipe.
90 0 50 11 63 75 12 5 16 0

TYP 84 A MEDI H. NR.

MASC

TYP 84 A MEDI H. NR.

MASC

Carefully press together both parts with necessary welding pressure (see scale). Do not release the locking handle before the complete cooling (approx. 40 secs.).

90 0 50 11 63 5 7

12 5 16 0
90 0 50 11 63 75 5 12 0 16

36

Geberit HDPE Installati 1.12.03

1/12/03

2:47 pm

Page 37

Geberit HDPE electro welding Preparation


Cut pipe square

Dry, clean and scrape welding ends. Remove burr. Welding ends must remain dry during the whole welding process.

3.5 cm 3,5 cm
40160 mm

40160 mm

200315 mm

37

Geberit HDPE Installati 1.12.03

1/12/03

2:48 pm

Page 38

Geberit HDPE electro weld sleeve coupling (for pipes 40 160 mm)

000/191

B.500.000/192

Insert pipe or fitting ends into the sleeve coupling.

Geberit Electro fusion machine ESG 40/200

3 cm 3 cm

Connect electrofusion machine, start welding procedure.

Electroweld sleeve coupling

After the END indicator has turned on, remove the connection cable. The proturding yellow indicator indicates whether the welding process was performed correctly.

Right

Wrong

If required for the sake of appearance, the electrical connector socket on 40160 mm dia. electrowelding sleeves can be removed after the end of installation work.

Note: Basically, electroweld sleeve couplings should not be welded twice. However, in exceptional cases a repetition can be done, but wait at least 1 hour until the socket has completely cooled down.

38

Geberit HDPE Installati 1.12.03

1/12/03

2:48 pm

Page 39

Geberit HDPE thermo sleeve coupling ( 200 315 mm)

1
B.356.176/001

Dry, clean and scrape welding ends. Remove burr. Welding ends must remain dry during the whole welding process.

Geberit Start switch 230 V

Mark insertion length 75 mm.

75 mm 75 mm
Electro weld sleeve coupling

Mount centering rings to ensure proper welding.

g 200 A = 4 mm 250 A = 5 mm 315 A = 6 mm

A = g-k

Insert pipe or fitting ends into the thermo sleeve coupling. Connect start switch cable. Press start button briefly. Welding time approx. 8 minutes.
- 10 C 0 C + 10 C + 20 C ca. 8 - 10 Min. ca. 7 - 9 Min. ca. 6 - 8 Min. ca. 5 - 7 Min.

Wait for at least 15 minutes after weld has been completed before removing the centering rings. Do not remove the plastic sheet insulation until the sleeve has completely cooled down.

Note: The same sleeve coupling cannot be welded twice , since the built-in thermo fuses shut off automatically after the necessary welding temperature has been

39

Geberit HDPE Installati 1.12.03

1/12/03

2:48 pm

Page 40

Prefabrication

Light weight easy to handle

Wide range of fittings, excellent tools and the light weight of Geberit HDPE = perfect performance for prefabrication.
Description The good characteristics of the Geberit HDPE offer an easy way to prefabricate pipe assemblies. Through the butt welding technique, the pipes and fittings can be easily connected to make many big combinations. Complicated labour at the site is eliminated by the clean and easy organized work at the workshop. Afterwards, at the site the prefabricated combinations can be assembled very fast. Advantages Simplified work Easy time management Time saving Higher performance Higher quality Professional impression Short time at the site No loss of material

40

Geberit HDPE Installati 1.12.03


1

1/12/03

2:48 pm

Page 41

Prefabrication
9 2

Procedure

Measurements (Preparation) Take measurements on site and mark the positions of all fixtures on the walls and floor.
70 60 60 70 55

1 8

16 14 10

170

Design drawing Prepare the design and detailed drawing. 2.1 Using the isometrics method
Part cc ./. total

1 2 3 4 5 6 7 8 9

Pipe Pipe Pipe Pipe .... ...

110 63 63 63 .....

450 620 765 .... ....

140 430 188 .... ...

310 190 577 ... ...

2.2 Using PE-DLS-software

41
1

Geberit HDPE Installati 1.12.03

1/12/03

2:48 pm

Page 42

Prefabrication
8

Jointing possibilities

Prepare pipes and fittings


B.600.000/020
9 10

Cut pipe square

Shorten fitting

Prefabrication of assemblies
11 12

Weld pipes and fittings together with the Geberit welding machine MEDIA or UNIVERSAL.

Installation on site

13 14

The prefabricated assemblies can be connected on site with the electroweld sleeve coupling.

15 16

42

Geberit HDPE Installati 1.12.03


1

1/12/03

2:48 pm

Page 43

Electric repair tool


(Art. No. 395.049)
9 2

Repairing holes in HDPE pipes and fittings and in PE concealed cisterns

1 7 8

1
6

Clean repair area well with scraper, knife or emery cloth.

Screw suitably sized insert onto front or side of heater.

Heat simultaneously repair area and patch.


3

Press softened patch quickly onto repair area.

Cut of projecting tail.

Clean the heater.

43
1

K
Nr at W . t .R ie se n Ku ns Ty ts Vo pe to "B W lt : A- ff- A Sc R 23 hw Y 0 ei " ss ap pa Dit Ba ra tin se te ge rst l (S ras ch se 45 w ei z)

e at ar p " ap Y R ss A wei "B ch z) -S ff ei o w st ch st (S 45 un e: A 0 el asse as str yp 23 T olt t B er n tting V at W r. iese Di N .R W

Geberit HDPE Installati 1.12.03

1/12/03

2:49 pm

Page 44

Thermal expansion sockets (application in buildings) Mounting instructions

2
9

B.500.000/250

maximal pipe length: 6 m !

at 0C (32F)

B.500.000/251

8 cm

10,5 cm

at 20C (68F)

10

Prepare pipe insertion end.

Mark insertion depth on the pipe. Consider outside temperature.

11

Remove yellow protection cap.

Lubricate pipe end and rubber seal. Only use soft soap, Silicone or Vaseline. Do not use mineral oil or grease !

12

On the building site, protect the seal from ingress of dirt. Wrap a felt bandage around and secure with adhesive tape.

13

Push the pipe into the expansion socket. Important: Fix each expansion socket with an anchor bracket !

14

Please note: The marking of the insertion depth and the assigned length of pipe on the expansion socket does not apply for buried pipes, unless the same temperature fluctuations as in the building drainage system are anticipated.

15 16

44

Geberit HDPE Installati 1.12.03


1

1/12/03

2:49 pm

Page 45

Underground drainage pipes for housing


9 1 5 6 7 8 2

Underground drainage pipes of Geberit HDPE Not only has Geberit HDPE proven itself excellently for many years for drainage systems inside of buildings such as: soil and waste stacks vent pipes connection and branch pipes collector pipes but it is also suitable for underground applications as: ground pipes domestic drainage pipes Criteria for underground drainage pipes 1. Tightness Environmental protection regulations do not permit leaking drainage pipes. Geberit HDPE is a reliable water drai-nage system which assures maximum dependability with regard to tightness.

2. Resistance to chemicals Geberit HDPE provides the assurance of universal resistance to the greatly diversified types of chemical attack by the disposal water, as well as by external factors (acidic soils). 3. Flexibility Geberit HDPE is a flexible, operationally reliable drainage system, even in soils in which a certain degree of settling of ground must be anticipated. 4. Resistance to frost Geberit HDPE has proven itself excellently for many years in frost endangered soils such as in Scandinavia. It can be used in temperatures ranging from 40 to 100C. 5. Material As in domestic drainage systems, the quality of the material is the main criterion for underground applications.

In addition to the attack from the inside, the pipes are also subjected to attacks from outside. Geberit HDPE excellently stands up to all these

2 3 1

1 Ground acids 2 Stray currents 3 Disposal water (with chemical and thermal attack) 4 No enter of roots

6. Friendly to the environment The Geberit HDPE drainage systems comply with environmental regulations.

45
1

Geberit HDPE Installati 1.12.03

1/12/03

2:49 pm

Page 46

Trench profiles
For all trenching work the local guidelines, standards and regulations must be observed.
8

Important for underground installation is correct laying of the pipe in the trench, as well as careful consolidation. B = Bedding The pipe must have a bedding of at least 100 mm. C = Consolidation Side fill to upper edge of pipe.

Profil V1A
20 cm

Profil U1A

20 cm

HS

P = Protective layer With trench profile 1A cover to above top edge of pipe over entire width of trench min. 300 mm HS = Safety height when using mechanical compactors: Vibration compactor 1,000 N HS = 0,4 m Vibration roller 3,000 N HS = 0,3 m Vibration roller 15,000 N HS = 0,5 m D = Consolidation stratum depth min. covering: In area of road 0,8 m Outside road area 0,5 m Max. covering: Up to 6 m without problem In cases of minimum coverings or heavy loading, measures such as load distribution plates or appropriate trench profiles are to be used. Traffic loads Heavy traffic Normal traffic

HS

P C B

10

P C B

min. 60 cm
11

Behavior: flexible Embedment Round gravel 0 30 mm Broken material 0 10 mm

Behavior: flexible Embedment Round gravel 0 30 mm Broken material 0 10 mm

12

Profil U4A

Profil U4B

D
P = 9 tons P = 6 tons
D
10 cm
10 cm
13

Away from roads: always P = 3 tons Filling material Grain size Round gravel 0 = 30 mm Broken material 0 = 10 mm
A

B A=D + min. 100 mm

B
14

Behavior: rigid Embedment in concrete PC 200 kg/m3

Behavior: rigid Embedment in reinforced concrete PC 250 kg/cm3

15 16

46

Geberit HDPE Installati 1.12.03


1

1/12/03

2:49 pm

Page 47

Guidelines for laying drainage pipes


For all trenching work the local guidelines, standards and regulations must be observed.
9 1 8 2

U B
7

Trench The trench is to be dug as narrow as possible but not narrower than the pipe diameter + 40 cm. The floor of the trench must be level and free from rocks and loose clumps. Correct elevation and slope are also important.

B = Bedding Under normal soil conditions the trench is provided with a bedding layer of round gravel (grading up to 30 mm) or of broken material (grading up to 10 mm) of a thickness of approx. 100 mm. The bedding layer must be compacted and tamped. In certain cases it will be neccessary to reinforce the ground.

U = Underpinning After the pipe has been laid, recesses are to be provided for sockets and flanges so that the pipe is supported along its entire length. The underpinning is to be done with a tamping post or the like. It must be done very carefully. If several pipes are laid, make sure that the lowest one is fully covered before the one above is placed. The pipe must lay flat, and it must be installed with

C = Consolidation layer The material is to be filled in layers of approx. 100 mm thickness. Tamping can be done by stamping with the feet, or with a special tool. The purpose of this material is to help prevent the pipe from deforming, so that it must be compacted well on both sides at the same time .

HS P
1 Ground load and possible traffic load 2 Shoring pressure

P = Protective layer Now fill in a layer of the same material (must not contain rocks which could cause point loading of the pipe) of at least 300 cm. Attention: To prevent the pipe from rising the trench is to be finish-filled on the same day up to and including the protection layer.

HS = Safety margin height For the further filling the available material is to be used. The trench must not contain rocks which cannot be lifted by hand. As soon as permitted by the safety margin height, this compacting can be done by machine. The regulations and byelaws on the refilling of trenches are to be observed.

Distribution of ground pressure The ground pressure and ground load distribution are governed essentially by the compaction. For calculation the appropriate standards and the local building and safety regulations are to be observed.

47
1

Geberit HDPE Installati 1.12.03

1/12/03

2:49 pm

Page 48

Rigid installation
8

Rigid fixation

The rigid fixings must be stronger than the possible expansion or contraction forces of the HDPE pipe.
9

Geberit pipes can be installed rigidly with relatively low effort, for which the following elements are required: 1 Concrete mound as an anchor point 2 Electroweld sleeve coupling 3 HDPE pipe

10 11 12 13 14 15 16

48

Geberit HDPE Installati 1.12.03


1

1/12/03

2:49 pm

Page 49

Underground installation of Geberit expansion sockets


9 2

PL (pipe length) ID (insertion depth)


8

In addition to the butt-welded and electrically welded connection, the expansion socket is an ideal connection in underground drainage systems. Since in such systems lower temperature differences are usually encountered than in stacks and connector pipes, smaller length variations can be accounted for. d For this reason in underground installations the distance between expansion sockets can be longer. The values calculated according to the formula PL A 0,3 d 0.006 and rounded off.

SL (socket length)

Please note: The scale found on the outer surface of the socket does not apply in the case of underground installations.

PL
4 cm

ID

4 cm

Nominal outside diameter d (mm) 110 125 160 200 250 315

Socket Pipe length Insertion length SL PL (for t depth ID 30C) (mm) PL (m) (mm) 140 15 130 140 15 130 140 15 130 220 20 230 220 20 230 220 20 230

Fitting of the underground expansion socket in the installations Insert beveled pipe to maximum socket depth, mark and pull back 40 mm.

Prepare the pipe end The pipe end should be chamfered and lubricated with soap to ease inserting.
3 2

49
1

Geberit HDPE Installati 1.12.03

1/12/03

2:49 pm

Page 50

Pipes penetrating through building walls


8

With regard to the ground line between the building wall and the street sewer, where extreme settling can occur, an installation mat must be wrapped around the ground line to act as a deflection leg. In such cases Geberit HDPE is an ideal material, since it assures tightness and at the same time provides maximum flexibility. Deflection leg The length of the deflection leg is dependent upon the expected settling and on the pipe diameter.
1 See page pipe 2 Settling 3 Insulation mat 4 HDPE pipe () 5 Foundation slab 6 See page lining DL = Deflection leg S = Insulation thickness S = expected settling

9 10

Length DL = 10 |/ S Note: The insulation must be thicker than the expected settling.
11

Expected settling S 20 40 mm 40 60 mm 60 80 mm

GeberitHDPE pipe 125 160 /200 315 125 160 /200 315 125 160 /200 315

Deflection leg DL 1,0 m /1,0 m 1,0 m /1,5 m 1,5 m /1,7 m

12 13 14

D d
15

H
Examples for water proofing see p. 18

16

50

Geberit HDPE Installati 1.12.03


1

1/12/03

2:50 pm

Page 51

Connection to Manhole
9 2

Open manhole

Plastic pipes should only be connected with manholes by means of a special manhole sleeve. Since settling of ground has to be expected such a sleeve must have the same ideal characteristics as Geberit HDPE: it must assure tightness and at the same time flexibility. A rubber ring provides the flexible seal between sleeve and plastic pipe.

1 7 8

1 2 3 4 5
6

Concrete Manhole sleeve Geberit HDPE pipe Bench Anchor point if required

Access pipe with oval access cover

1 Concrete 2 Manhole sleeve 3 Access pipe (Art nr. 3xx.454.16.1)

Geberit access pipe with oval access cover

51
1

Geberit HDPE Installati 1.12.03

1/12/03

2:50 pm

Page 52

Drainage requirements for bridges


8

Traffic safety/Maintenance Geberit HDPE also meets the special requirements for all types of bridges. The pipes and the wide range of fittings provide an easy design and execution at the construction site. The smooth walled pipes make a troublefree maintenance and service possible, whereby all modern cleaning equipment can be used. Frost protection Geberit HDPE can be installed in temperatures down to 40C. However, to ensure water flow in the pipe an automatic-controlled heat trace can be fitted.
11

9 10

Heating trace with surface thermostat

Ground water protection Where the bridge crosses a river, railway or another road, an absolutely watertight system is essential. In accordance with the anti-pollution laws, protection must be maintained in the event of an accident.

12

Piping Arrangement Collector pipe (The inlet into the collector pipe is made with 135C Y-branch fittings).
1 Silt trap 2 Connector pipe 3 Collector pipe

13 14 15 16

52

Geberit HDPE Installati 1.12.03


1

1/12/03

2:50 pm

Page 53

Drainage of Bridges Installation Indications


Laid in concrete Piping embedded in the bridge structure can never be replaced. It is therefore essential that a drainage material which offers the greatest security is used. When choosing this material, the consolidation of the concrete, temperature variations, contraction and creep, as well as the prestressing of the bridge must be taken into consideration.
9 1 7 8 2

Thermal movement
6

Example 1

Example 2

The following points must be observed Location of supports or piles Horizontal movement of the bridge on the supports Deflection of the bridge Swaying of the bridge The watertightness of the expansion socket (example 1) In the case of example 2 an expansion funnel is required to absorb the lateral movements.
Expansion socket Expansion funnel

Fixing
4

The spacing of the guide brackets for HDPE piping is 1,5 m and may not be exceeded. With all plastic piping, the pipe bracket should have a minimum width of 60 mm, in order that the stresses due to the weight of the filled pipe is well distributed.

Guide bracket

53
1

Geberit HDPE Installati 1.12.03

1/12/03

2:50 pm

Page 54

Low pressure installation


8

Low pressure application

Generally the Geberit HDPE product range is designed for water drainage systems. For the low pressure range, e. g. swimming pool, pipework through circulation pumps, Geberit has established maximum admissible stressing values for an endurance life of 10 years. All connections must be butt weld joints, electroweld sleeve couplings or flange joints. Suitable fitting range for low pressure application see page 4.

Pressure Temperature Longterm rupture strength

max. 1,5 bar max. 30C 10 years

10

Discharge pipeline of a pump set

The Geberit HDPE range of products can also be used for the discharge pipeline of a pump set, provided that the mechanical stress is low, only of short time and no thermal loaded medium (e.g. warm water) is pumped. When designing discharge pipelines for drainage pumps the following important points should be observed:
11

Vertical stack

Vertical stack

Pumped pressure pipeline

Pumped pressure pipeline

12

Collector pipe

Collector pipe

1. The discharge pipeline has to be installed higher than the lowest installed appliance by means of a pipe loop.

2. If the flow rate is smaller than 5 l/s the vertical fall section of the pipe loop has to be increased.

13

Vent 50/56 Vent 50/56 Vertical stack Vertical stack Side vent 50/56 Pumped pressure pipeline Pumped pressure pipeline

Side vent 50/56 Vertical discharge stack


14

Pumped pressure pipeline V > 5 l/s

Collector pipe Collector pipe


15

3. If the flow rate is above 5 l/s the vertical stack has to be vented with a ventilation pipe of at least 50 mm inside diameter.

4. Long horizontal collector pipes have to be vented. The minimal inner diameter of the vent pipe must be 57 mm or 2 dimensions smaller than the discharge pipe. The ventilation pipe must be higher than the total delivery head of the pump and must go above the roof.

54
16

Geberit HDPE Installati 1.12.03


1

1/12/03

2:50 pm

Page 55

External pressures Internal negative pressures


External pressures Geberit HDPE pipes will withstand external pressures according to the table below depending on the pipe diameter.
9 1 8 2

The maximum level of the groundwater table has to be taken into account when designing Geberit HDPE pipelines in a groundwater area.

Permitted external pressures

Pipe 32 40 50

Wall thickness s (mm) 3 3 3 3 3 36,2 6,29,8

External pressure bar 4,8 2,5 1,4 0,82 0,64 0,36 0,18

m Water column 49,0 25,5 14,3 8,4 6,5 3,7 1,8

56 63 75160 200315

For adequate fittings see page 4

Internal negative pressures

Geberit HDPE pipes will withstand internal negative pressure according to the table above depending on the pipe diameter.

Geberit HDPE pipes are sometimes used as suction pipelines for pumpsets. The higher the suction lift is, the higher the negative pressure inside the pipeline. Important with such an installation is that the foot valve and strainer are not blocked. Foot valve and strainer of the suction pipeline should be kept free from debris, possible blockage could lead to additional pressure increase.

Permitted internal negative pressures

Pipe 32 40 50 56 63 75160 200315

Wall thickness s (mm) 3 3 3 3 3 36,2 6,29,8

Internal negative pressure bar 1,0 1,0 1,0 0,82 0,64 0,36 0,18

For adequate fittings see page 4

55

Geberit HDPE Installati 1.12.03

1/12/03

2:50 pm

Page 56

Fire protection
8

Use only for:

Depending on the type of building different fire protection will be required (see local fire regulations for buildings).
9

Building parts The requirments for building components are classified in fire resistant classes in order to maintain maximum integrity of the relevant wall, floor or ceiling.

Fire resistance class F 30 F 60 F 90 F 120 F 180

Fire resistance time (minutes) 30 60 90 120 180

Material (example) 50 mm gipsum board 100 mm brick-wall 120 mm brick-wall 150 mm brick-wall 250 mm brick-wall

10

Passing through wall and ceiling The weakening of a fire protection wall or ceiling is not allowed under any circumstances.

The integrity of the wall or ceiling will be maintained for the permitted periods, when Geberit fire sleeves are used as illustrated.

11 12

8 9 10

8 9 10

8 9 10

8 9 10

8 9 10

Installation and time of fire resistance

STOP! STOP!
11

12 1
11

STOP!
11
12 1

STOP!
11
12 1

12 1

STOP!
11
12 1

Installed on one side of the wall Fire class F 90

Installed on both sides of the wall Fire class F 90

56

5 6 7

Min

11 8 9 10

12 1
2 3 4

90

Min

Installed on the ceiling Fire class F 120

5 6 7

5 6 7

5 6 7

90 Min 90 Min

P!

90 Min

90 Min

2 2 3 4

OP! STO

90 Min

2 3 4

2 3 4

2 3 4

3 4

6 7 5 5 6

13 14 15 16

Geberit HDPE Installati 1.12.03


1

1/12/03

2:50 pm

Page 57

Geberit HDPE Fire stoppers


9 1 2

Fastening tongue with slot

Rivets for fixation of internal- and outside-box

Holder for safety pin during transport

Stainless steel box

Snap-locking
7

Soft-PE insert for centering and acoustic insulation Firestop-material

Safety pin (after fixation)

Measurements:

D D1

D
A

D1
A A B B

(G b it PE)
5

Geberit HDPE 50, 56, 63, 75 90, 110, Silent 75 125, Silent 110 160 200
4

D (mm) H (mm) D1 (mm) A min (mm) B min (mm) 165 205 225 265 315 110 110 110 110 110 110 150 170 220 270 120 140 150 170 195 150 190 210 260 310 3x 4x 4x 4x 4x

Art. Nr. 365.814.00.1 367.814.00.1 368.814.00.1 369.814.00.1 370.814.00.1

Installation instructions
2.

Fill gap between pipe and wall using strong cement.

The Fire sleeve can be easily wrapped around the pipe using quick snap locking action.

The Geberit HDPE Fire sleeve must be fitted to the wall using metal dowels.

The Geberit HDPE Fire sleeve must always be fitted to the wall and not built into the wall.

57

Geberit HDPE Installati 1.12.03

1/12/03

2:50 pm

Page 58

Physical characteristics of Geberit HDPE


8

Physical characteristics of Geberit HDPE The data given below was obtained with test specimens of pressed plates and foils. Individual values can deviate from these average values depending on the conditions under which the test specimens were made.
9

Characteristic Density Reduced specific viscosity (viscosity coefficient) Melt-flow index MFI 190/5

Unit g/cm3 dl/g g/10 mins.

Test method DIN53479 ISO/R 1191 DIN 53735

Test specimen Plate 0,1% solution in decalin granulate 0,953...0,955 3,0 0,4...0,7

Mechanical characteristics, measured under standard climatic conditions 23C, 50% relative air humidity**
10

Tensile strength Elongation at yield stress Ultimate tensile strength Elongation at break Limit bending strength Torsional rigidity Bending creep modulus 1 minute value Indentation hardness 30 second value Shore hardness D Impact strength Impact strength at +23C and 40C Thermal characteristics Crystallite melting range Mean linear expansion coefficient between 20 and 90C Heat conductivity at 20C

N/mm2 % N/mm2 % N/mm2 N/mm2 N/mm2 N/mm2 mJ/mm2 mJ/mm2

DIN 53455. ISO/ R 527; test velocity 125 mm/min DIN 53452 DIN 53447 Bending creep test b 3 N/mm2 DIN 53456 Test strength 132, 4N DIN 53505 DIN 53453 DIN 53453

Test specimen 3 with measurements in the ratio 1:4 Standard small bar injection moulded 60 mm x 6,35 mm x 2 mm 120 mm x 20 mm x 6 mm Sheet, 4 mm Sheet, 4 mm Standard small bar, moulded*** Standard small bar, injection moulded

22 15 32 > 800 28 240 800 40 60 15


11

C K1 W mK

Polarisation microscope DIN 52328; ASTM D 696 DIN 52612 sheet method

Microtome section 50 mm x 4 mm x 4 mm Plate, 8 mm Injection, moulded

127...131 1,7104 0,43

12

Electrical properties, measured under standard climatic conditions of 23C, 50% relative air humidity Specific transmission resistance Surface resistance Electric strength Dielectric index r, (relative dielectric constant) at 2 106Hz Dielectric loss factor tan at 50 Hz 103Hz 104Hz 105Hz Track resistance Arc resistance In a number of countries, a tensile test test is carried out on a test specimen taken in longitudinal (or transversed) direction of the pipe, e.g. in Great Britain according to BS 3284. The values thereby obtained do not necessarily need to agree with those given in the table, which applies especially for the elongation at break. cm kV/cm DIN 53482 VDE 0303 Part 3 DIN 53482 VDE 0303 Part 3 DIN 53481 VDE 0303 Part 2 DIN 53483, VDE 0303 Part 4 (immersion method) DIN 53483, VDE 0303 Part 4 Foil, 0,2 mm Sheet, 1 mm Foil, 0,2 mm >1016 >1013 700
13

Foil, 0,2 mm Foil, 0,2 mm

2,50 6 5 5 6 104 104 104 104

14

DIN 53 480 VDE 0303 Part 1 DIN 53484 VDE 0303, Part 5 The values given above relate exclusively to the corresponding test methods or test specimens. Results which are obtained with specimens taken from pipes may not agree.

Sheet 3 mm 120 mm x 120 mm x 10 mm

KA 3c KC > 600 L4

In contrast with injection, moulded specimens are free from flow orientations. This strongly influences the test result. Measurement with moulded bars is therefore preferred.
15 16

58

Geberit HDPE Installati 1.12.03


1

1/12/03

2:50 pm

Page 59

Ecological properties of Geberit HDPE


9 2

Polyethylene (PE) is a simple compound of carbon and hydrogen atoms, harmless to man, animals and plants.

1 7 8

PE environmental loads relate to the fields of manufacture and disposal. In addition to the raw material crude oil, energy is used for the preparation of the plastic granulate and in the manufacture of the products.

PE is the perfect material for drainage systems from an ecological point of view. It has a long life span, no toxic gases rises from incineration (e. g. hydrochloric acid HCL from PVC) during disposal. It consumes much smaller quantities of energy during fabrication process and transport than steel, cast iron or copper pipes.

59
1

Geberit HDPE Installati 1.12.03

1/12/03

2:50 pm

Page 60

Ecological properties of Geberit HDPE


8

Environmental impact of different pipe material (Ecobalance)

The diagram shows the environmental impact of 1 m pipe 110 during its expected life, beginning with its raw material and ending with its disposal. The environmental impact is measured in environmental points (UP), according to the regulations of the Swiss Federal Office of Environment, Forest and Countryside (BUWAL), Publication series 132 and 133.
9

UP/m pipe 7000

10

6000 Disposal of pipes Manufacture of pipes 5000


11

Manufacture of raw material

4000
12

3000

13

2000

1000
14

0 Cast iron 50% recycled tin plate Cast iron 100% recycled tin plate PVC ABS HD-PE

15 16

60

Geberit HDPE Installati 1.12.03


1

1/12/03

2:50 pm

Page 61

Comments on the individual properties


9 2

Geberit High Density Polyethylene HDPE: Density 951 955 kg/m3 The density of various polyethylene types can be 910 960 kg/m3. The Geberit type at up to 955 kg/m3, is of the hard quality and has increased durability properties. HDPE is lighter than water, which is beneficial particularly with regard to transportation and installation.

1 8

Tempered 10 mm per meter (licence Geberit International AG) The safest way of avoiding the inevitable heat reserves (shortening of dimensions) after heat load in the plastic pipe, is to take preventative measures during manufacture. Geberit HDPE pipes are therefore stored in hot water baths after manufacture. This process increases the safety of the joints, as there is no chance of joints pulling apart later due to shortening of length.
7

Resistance to cold When Geberit HDPE parts are filled with water and then freeze, they stretch elastically as the ice expands. Once the ice melts, they resume their original shape, remaining completely intact and undamaged.

Flexibility The flexibility of the piping material can be the main criterion in certain buildings or on bridges, especially when pipes have to pass through expansion joints or are in buildings, which are subject to traffic vibration.

Melt-flow index 0,4 0,5 g/10 min. This describes the working properties of the pipe and at the same time gives information on the molecular weight, which is crucial for a number of raw material properties. The smaller the melt-flow index, the higher the molecular weight and thus the pipes resistance to stress corrosion.

Heat conductivity 0,43 W/m K HDPE is a bad heat conductor; for this reason the pipe does not become completely warmed through when heat loaded for a short period. Heat loss is about 90% less, for instance, than a similar copper pipe.

Resistance to radioactive effluents There is no risk of damage as a result of slightly radioactive water. However, please ask the manufacturer for more information relevant to the particular application.

Resistance to abrasion Drainage systems are increasingly becoming hidden refuse chutes. A pipes resistance to abrasion is a particularly important factor in branch pipes, soil stacks and ground pipes. HDPE is highly resistant to abrasion; its extra thick walls offer additional protection.

61
1

Geberit HDPE Installati 1.12.03

1/12/03

2:50 pm

Page 62

Comments on the individual properties


8

Heat expansion 0,17 mm/m K Heat expansion of HDPE is relatively high. As a rule of thumb, for every 50C increase in temperature, an expansion of 10 mm of linear meter of pipe can be anticipated.
9

Resistance to hot water Geberit HDPE can be safely used as waste pipe with no mechanical load, up to 80C. Temperatures of up to 100C for short periods (e.g. surges of steam) are permissible.
10

Resistance to impact Geberit HDPE is unbreakable at room temperature. Its resistance to impact is very high even at extremely low temperatures (down to approx. 40C) and thus meets the requirements for outlet pipes.
11

Condensate Geberit HDPE is a poor conductor of heat. No condensate should form during short periods of undercooling.

12

Behaviour in fire Plastics are inflammable. However, the classification of plastics according to the usual fire test for construction materials does not permit a valid statement on the behaviour of plastic construction parts in the event of a fire.

13

Tightness Many years of experience with welding HDPE-Pipes, have shown that the butt welds do not give any problems as the welding parts are circular on the inside and do not add to the normal risk of blocking.

Noise HDPE is a soft material with a low E-modulus. HDPE limits solid-borne conduction, but airborne noise should be insulated. This can be done by means of the duct wall, HDPE Silent or Geberit Isol.

14

Chemical resistance Because of its paraffinic structure, Geberit HDPE is highly resistant to chemicals. Its resistance can be summarized briefly as follows: Geberit HDPE is insoluble in all inorganic and organic solutions at 20C. Geberit HDPE is only soluble in aliphatic and aromatic carbons and their chlorinating products at over 90C. The material will be attacked by heavily oxidized media (conc. HN03, conc. H2 S04) when exposed over long periods at room temperature.

15 16

62

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 63

Comments on the individual properties


9 2

Non-conductive Plastics have an excellent reputation as insulators in the electronics industry. HDPE cable protection ducts, cast resins, insulating paint etc.

1 8

Sealing material Although the chemical resistance of the seal does not equal that of HDPE, there is no risk of the seal being destroyed, because the rubber ring is installed under compression on all sides and therefore cannot swell. In addition, the wetting factor of the rubber ring in the joint is very low. Many years of experience have shown that the sealing material can endure even the harshest conditions. NB: Such conditions do not occur in drainage pipes. Free halogens (chlorine, bromine etc.) cause halogenised polyethylene and hydrogen halide to form at room temperature. The halogenised polyethylene has different physical and chemical properties from the original hydrocarbon, but the polymer is not destroyed. Geberit HDPE should therefore not be used at all in areas where free halogens are produced or used. The only criteria to be observed here are the purpose for which the pipe is intended and the concentration of halogens. Solar radiation Geberit HDPE pipes are protected against ageing and embrittlement caused by UV rays by the addition of approximately 2% soot.

Protection against blockages HDPEs water-repelling properties are highly beneficial in this regard. Rapid outflow of water Prevention of deposits

Welding temperature Thermoplasts are processed with a high level of energy efficiency. The temperatures required are relatively low in comparison with metals. The welding temperature for HDPE is approximately 230C. Simple tools allow for easy processing.
4

Non-toxic Plastics are well suited for use in the food industry as packaging material, containers, bottles etc. Geberit HDPE pipes are used for milk transportation lines in mountain areas and in the food canning and packing industry.

Scope of use Geberit HDPE pipes are designed for drainage systems. Their use in low-pressure areas (swimming pools, transportation lines etc.) is subject to a maximum pressure load of 15 m Water Column (1,5 bar) and a temperature of 30C (10 years). There is also a certain range of moulded fittings.

Painting Geberit HDPE is not suitable for painting. Its water repellent properties and the flexibility of the material both have a negative impact on paint. If painting is unavoidable, the paint product to be used should be tested for compatibility with the HDPE.

63
1

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 64

The importance of tempering


8

Manufacturing process of Geberit HDPE pipes


9

1 Driving motor 2 Raw material 3 Extruder

4 Screw 5 Electric strip heaters 6 Mould

7 Gauging device 9 Drawing device 8 Cooling bath 10 Finished pipe

As a result of manufacturing, the molecule chains are stretched and than cooled sown from about 230C to 40C. This enormous drop in temperature results in tensile stresses which are frozen in by the cooling down process.

10

Stretched molecules after manufacturing When hot water flows through a streched pipe or the pipe is heated up by doing a welding joint, e.g. with an electroweld sleeve coupling, the expanded molecules relax and return to their normal state. The pipe becomes shorter. Molecules after Geberit annealing process
12

11

Effects of annealing of Geberit HDPE pipes

The safest way of avoiding the inevitable heat shortening of dimensions after heat load in the plastic pipe is to take preventative measures (Tempering) during manufacture. Geberit pipes are therefore stored in a hot water bath after manufacture, this allows the expanded molecules to relax and return to their normal state = No stresses on Geberit pipes.
13

Length = 5000 mm

After manufacture
14

Admitted shortening according to standards 150 mm

Max. admitted shortening according to Geberit licence 50 mm


15

Without tempering, shortening of dimensions can create gaps between pipe and fitting, pipes can be pulled apart high risk of leakage!

Tempering of Geberit pipes reduces mechanical stress and joints and fixations. Through this process even the high precision requirements for electroweld sleeve couplings can be met.

64

16

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 65

The significance of the pH value


9 2

One of the most crucial factors in selecting a material for a drainage installation is the chemical loading of the effluent being discharged. Effluent with a low or a high pH is harmful because of its corrosive effects. E. g. some drain cleaning fluids have a pH value of up to 12.
8

Therefore in order to select the most suitable material to handle a specific discharge it is important not only to know the pH value of the effluent but the chemical resistance of the pipe materials. (see Chemical Resistance tables on pages 65 to asses the performance of Geberit HDPE at various temperatures) The pH value is therefore important in assessing the chemical level as it will indicate whether the effluent is acid, neutral or alkaline. The pH scale ranges from 0 to 14 (see table below).

increasingly acid

increasingly alkaline

8
NEUTRAL

10
slightly alkaline

11

12

13

14

very acid

slightly acid

very alkaline

HDPE . . .
. . . can be used safely with pH values from 0 to 14. . . . is therefore suitable, for example, for use with effluents containing over 30% hydrochloric acid.

pH values of some drinks and cleaning agents pH-value 2,8 3,5 2,2 2,8 9 13 2 4

Cola drinks Apple juice Tartaric acid Citric acid Washing solutions Toilet cleaner

65
1

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 66

Chemical resistance list


8 9 10 11 12 13 14 15 16

66

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 67

1 1 2 3 4 5 6 7 8

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 68

Chemical resistance list


8

Explanation
When the pipe wall material comes into contact with substances flowing through the pipe, different processes can take place, such as the absorption of liquid (swelling), the extraction of soluble elements in the material (shrinkage) or chemical reactions (hydrolysis, oxidation etc.), which can sometimes cause the properties of the pipes or pipeline parts to change. The performance of pipes and pipeline parts when in contact with effluent substances can be classed as follows: q Resistant The pipe wall material is generally regarded as being suitable
Limited resistance
Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C
9

The suitability of the pipe wall material must be checked in each individual case; if necessary, further tests should be carried out. Not resistant The pipe wall material is generally regarded as being unsuitable. The following symbols and abbreviations are used to indicate the composition of the flow substances: % L Percentages refer to mass proportions in %. Aqueous solution, mass proportion > 10%.

VL Aqueous solution, mass proportion <= 10%. GL Aqueous solution saturated at 20C. TR Chemical is at least technically pure. H S G Normal commercial composition. Traces < 0,1% Usual mass proportion of any saturated solution or dilution.

Data is based on immersion tests without mechanical load and reflects current levels of knowledge. No claims under guarantee

The following data is required for a declaration of chemical resistance: Corrosion medium, composition (chemical description), DIN safety data sheet Temperature Proportion (concentration) Information on reaction time, frequency, flow quantity Other flow media

A Acetic aldehyde Acetic aldehyde Acetic aldehyde+acetic acid Acetanhydride (acetic anhydride) Acetamide Acetanhydride Acetic acid Acetic acid Acetic acid butyl ester Acetic ether (ethylacetate) Aceto-acetic acid Acetone Acetone Acetophenone Acetylene Acronal dispersions Acronal solutions Acrylonitrile Acrylic acid-emulsions Acrylic acid ethylester Activine (chloramine 1%) Adipinic acid Adipinis acid ester Allyl acetate Allyl alcohol Allyl chloride Alum (potassium aluminium sulphate) Aluminium chloride Aluminium chloride Aluminium chloride, solid Aluminium fluoride Aluminium hydroxide Aluminium metaphosphate Aluminium sulphate Aluminium sulphate, solid Amidosulphates (amido-sulphonic acid salts) Amido-sulphonicacid Amino acids Ammonia, gaseous Ammonia, liquid Ammonia solution (ammonium hydroxide) Ammonium acetate Ammonium carbonate and bicarbonate of ammonium Ammonium carbonate Ammonium chloride (sal-ammoniac) Ammonium dihydrogen phosphate Ammonium fluoride Ammonium hydrosulphide Ammonium metaphosphate Ammonium nitrate Ammonium phosphate Ammonium sulphate Amonium sulphide Ammonium thiocyanate Amyl acetate Amyl alcohol Amyl chloride Amyl phthalate Anilin (phenylamine)

40 TR 90:10 TR TR TR 70 100 100 VL TR TR H H TR 100 GL

q q q q q q q q q q q q q q q

q
q q


q q q


q q q q q q

10


q q q q q q q q
11


q q q q q q q


q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q

96 any VL GL GL


q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q
12

any

any any 100 100 any any GL any any GL L any any any any any TR TR 100 GL

13 14


q q q q q q

15

16

68

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 69

Chemical resistance list


9 2

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C

Anilin chlorhydrate any Anise oil TR Anone (cyclohexanone) TR Anthraquinone sulphonic acid 1 Antifomine (benzaldoxime) 2 Anti-freeze H Antimonious trichloride, anhydrous Antimonious trichloride 90 Antimonious pentachloride Apple juice H Apple wine H Aqua regia TR Arklone (= reon, frigen) (Chloro fluorcarbon CFC) 100 Aromativ oils Arsenic any Arsenic acid anhydride Ascorbic acid (vitamin C) Asphalt B Barium carbonate chem. precipitated 98/99% Barium hydroxide Barium salts Battery acid (sulphuric acid,~34%) Baysilon separating agent Beef fat Beef suet Beeswax Beer Beer colouring Benzaldehyde Benzaldehyde in isopropyl alcohol Benzene Benzaldoxime (antiformine) Benzene/benzol mixture 80/20 Benzene sulfonic acid Benzoic acid Benzoyl chloride Benzyl alcohol Benzyl chloride Bichromate sulphuric acid (chromic acid/sulphuric acid) Bismuth nitrate, acqueous Bismuth salts Bisulfite solution Bitumen Bleach solution with 12,5% active chlorine Bone oil Borax (sisodic tetraborate) Boric acid Boric acid methyl ester Boric trifluoride Brake fluid Brandy Bromic acid Bromin, liquid and gaseous Bromochloromethane Butadiene Butadiene Butandial Butane, gaseous Butanol

q q q q q q

q q q q q q q q q q

q q

q q


q q q q q q q


q q q q

q q q q q q

Butanon Butantriol Butindial Butoxyl (methosybutylacetate) Butter Buttermilk Butyl acetate Butyl acrylate Butyl alcohol Butyl benzylphthalate Butylene, liquid Butylene glycol Butylene phenol Butylene phenol, p-tertiary Butyric acid C Calcium carbide Calcim carbonate Calcium chloride Calcium hydroxide (lime) Calcium hypochlorite (chlorinated lime) Calcium nitrate Calcium oxide (powder) Calcium phosphate Calcium sulphate (gypsum) Calgon (sodium hexametaphosphate) Campher Campher oil Cane sugar Caoutchouc dispersions (Latex) Carbazol Carbol (phenol) Carbolic acid (phenol) Carbon bisulphide Carbon dioxide (soda water) Carbon tetrachloride Castor oil Caustic ammonia (ammonium hydroxide) Caustic potash solution Caustic soda (sodium hydroxide) CD 2 up to 5% CD 3 up to 5% Cetyl alcohol Chloracetic acid Chloral hydrate Chloramine T Chloramine T Chloric acid Chloric acid Chloric acid Chlorinated carbon dioxide ester Chlorinated lime (calcium hypochlorite) Chlorinated paraffin Chlorine Chlorine Chlorine, gaseous, damp Chlorine, gaseous, damp Chlorine, gaseous, damp Chlorine, gaseous, dry Chlorine, liquid Chloroacetic acid ethyl ester Chloroacetic acid methyl ester

any 100

TR

TR TR TR TR any

q q q q q q q q q q q q

q q q q


q q


q q q q q q q q


q q

any any any H 100

H H H any 1 TR 2

q q q q q q q q q q q q q q q q q

q q q q q q q q q q q

q q q q

GL any GL GL 50


q q q

GL any TR TR


q q q q q q q q q q q q

any TR TR

any any TR any TR TR any 50 any

q q q q q q q q q q q q q q q q

q q q q q q q q q q

q q q q q q q q q q


q q q

TR any

q q q q


any any q q q q q q q q q q q q q q q q q q

any any TR VL 1 10 20 GL 100 VL GL 0,5 1,0 97 TR TR TR TR

q q q q q q q q q q q q q q q q q q q q q q q q q q


q q q q q

q q q


q q q q q q q q q q q q

H 40 any 50 TR any TR any

q q q q q q q q q q q q q q q q

69
1

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 70

Chemical resistance list


8

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C
9

Chlorobenzol Chloroform Chloromethyl, gaseous Chlorsulphonic acid Chromanode mud Chromic acid Chromic acid Chromic acid/sulphuric acid/water, 50/15/35 Chromic alum Chromous salt Chromium sulphuric acid Chromium sulphuric acid Chromium trioxide Citraconic acid Citrate Citric acid Citronaldehyde Citrus juices Clophene (polychlorinated biphenyls PCB) Coal tar oil Coca Cola Cocoa Coconut oil alcohol Coconut oil Cod liver oil Coffee Cognac Cola conzentrate Compressed air containing oil Cooking oil, vegetable and animal Copper chloride Copper cyanide Copper fluoride Copper nitrate Copper nitrate Copper salts Copper sulphate Corn oil Corsolin (disinfectant; chlorophenol soap solution) Cover paint Creosote Cresol Cresol Crotonaldehydo Crude oil Crystalline acid Crystal oil (solvent naphtha) Cumarone resin Cyclanone Cyclanone Cyclohexane Cyclohexanol Cyclohexanone (Anone) D Decahydronaphtalene (Decalin) Dessicator oil Detergents Developing solutions (photographic) Dextrine

TR TR TR TR 20 50

q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q

q q q q q q q

any any TR any 50 any any any TR

q q q q q q


q q

100


q q

G TR TR G


q q q q q q q q q q q q q q q q q q q q q q q q q q q

GL any 30 GL GL any TR VL


q q q

Dextrose (glucose, grape sugar) Diamin hydrate Diethyl ether (ether, ethyl ether) Diethylene glycol Di-2-ethylhexylphthalate (DOP) Diethyl ketone 1,2-Dibromoethane Dibuthyl ether Dibutylphthalate Dibutylsebacate Dichlorethylene Dichlorbenzene Dichloracetic acid Dichloracetic acid Dichloracetic acid methyl ester Dichlorodiphenyltrichloromethane (DDT, powder) Dichlorpropane Dichlorpropene Dielectric (transformer oil) Diesel fuel Diglycolic acid Diglycolic acid Dihexylphthalate Di-isobutylketone Di-isopropylether Dimethylamine Dimethylformamide Dimethylsulfoxide Disodic phosphate Disodic sulphate Disodic tetraborate (Borax) Dinonylphtalate Dioctylphtalate Dioxan Diphenylamine Diphenyloxide Dispersions Distilled oils Dodecyl benzene sulphonic acid Dry potash (potassium hydroxide) Dyes E Electrolytecbaths for electroplating Emulsifying agents Emulsifying agents (Tenside) Emulsionen (photographic) Epichlorohydrin Epichlorohydrin Epsom salts (magnesium sulphate) Ethane Ethanol (rectified spirit, ethyl alcohol, wine spirit) Ether (sulphuric ether, diethyl ether) Ethyl acetate Ethyl alcohol (rectified spirit, ethyl alcohol, wine spirit) Ethyl alcohol, denatured (2% Toluol) Ethyl alcohol (fermation mash) Ethyl alcohol + acetic acid (fermentation mix) Ethyl benzene

any TR TR

q q q q q

q q q q q q



10

TR TR TR TR TR 50 TR TR

q q
q q q q q q q q q q q


100 H 30 GL TR TR TR TR q q q q q

11


q q

12

q q q
q q q q q q q q q q q q

any TR TR TR


q q q q q q q q q q q

13


q q q q

50

90 100 TR TR TR L H TR TR TR


q q q q q q q q q q


any H q q q q q q q q q q


q q q q q q
14


q q q q q q q q q q
15

any


q q q q q q

96 TR TR 96 96 G G TR

TR

18

q q q q q


q q


q q


16

70

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 71

Chemical resistance list


9 2

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C

Ethyl chloride Ethylene Ethylene chloride Ethylene chlorohydrin Ethylene dichloride (Ethylene chloride) Ethylene diamine Ethylene diamin tetra-acetic acid Ethylene bromide Ethylene chloride (dichlorethylene) Ethylene glycol Ethylene oxide, gaseous Ethylene oxide, liquid Ethyl ether (Ether, Diethylether) 2-ethylhexanol Ester, alphatic Exaust gases, containing hydrogen fluoride containing hydrogen fluoride containing carbon dioxide containing carbon monoxide containing nitric oxide containing nitric oxide containing nitric oxide containing oleum containing oleum containing hydrochloric acid containing sulphur dioxide containing sulphuric acid containing sulphuric acid (damp) containing sulphur trioxide (oleum) containing sulphur trioxide (oleum) F Fatty alcohol Fatty alcohol sulphonate (cyclanone) Fatty alcohol sulphonate Fatty acids (technically pure) Fatty acids Fatty acid amides Fermentation mash (ethyl alcohol) Fermentation mix (ethyl alcohol + acetic acid) Ferrous chloride Ferric chloride Ferric nitrate Ferric sulphate Ferrous sulphate Fertilizer salts Fir needle oil Fixative salt (sodium thiosulphate) Floor polish Flowers of sulphur (elementary sulphur in powder form) Fluoride Fluobolic acid Formaldehyde (formalin) Formalin (acqueous formaldehyde) Formamide Formic acid Formic acid Formic acid Formic acid Freon 12 Fruit juices

TR TR TR TR


q q q q q q q q q q q q q


TR TR TR TR TR S S any any S 5 >5 S 5 any any any any S S q q

Fruit juices, unfermented Fruit juices, fermented Fruit wine Fruit pulp Fruit tree carbolineum Fuel oil Furfur alcohol Furfurol Furniture polish G Gas liquor Gelatine Gin Gypsum (calcium sulphate) Glaubers salt (sodium sulphate) Glucose (grape sugar, dextrose) Glue Glutine glue Glycerin Glycerin chlorohydrine Glycocoll Glycol Glycolic acid Glycolic acid Glycolic acid butyl ester Glysantine Grape sugar (glucose, dextrose) Gravy H Halothane Heptane n-Heptane Hexadecanol (cetyl alcohol) Hexafluorosilicic acid Hexamine Hexane n-Hexane Hexantriol Hchst drilling agent Honey Hydraulic fluid Hydrazine hydroxide Hydroammonium sulphate (ammonium hydrosulphate) Hydrobromic acid Hydrochloric acid Hydrochloric gas, dry+damp Hydrocyanic acid (prussic acid) Hydrocyanic acid Hydrofluoric acid Hydrofluoric acid Hydrogen Hydrogen bromine, gaseous Hydrogen peroxide Hydrogen peroxide Hydrogen peroxide Hydrogen sulphide Hydrogen sulphide, gaseous Hydrogen superoxyde Hydrogen superoxyde Hydroquinone

H H H TR

q q q q q q q q q

q q q q

q q q q


q q

q q
q q q q q q q q q q q q q q q q q q

any 40 GL any any H any VL H 37 70

q q q q q

q q q q q

q q q q q

any

q q q q q q q q q q q q q q q q q q

q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q


TR TR 32 any TR TR TR q q q q q q q q q q q

L H 100 TR G G GL any L GL any any H any

q q q q q q q q q q q q q q q q q q q q q q q q q q


q q q q


q q q q q q


q q q q q q q q q q q q q q


q q

q
q q q q q q q q q q q q q q q q q q q

L any 50 any TR 10 TR 50 70 TR TR 10 30 90 GL TR 30 90 L


q q

TR TR 40 40 TR 10 50 85 TR 100 G


q q q q q q q

q q q q q q q q q q

q q q q q q q q q q q q q q q q q q

q q q q q q q q q q q

71
1

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 72

Chemical resistance list


8

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C
9

Hydrosilicofluoric acid Hydrosilicofluoric acid Hydrosulphite Hydroxylamine sulphate Hypochlorous acid Hypophosphite I Ink Interlacing agent Insecticides lodine-potassium iodide (3% iodine) Isobutyl alcohol Iso-octane Isopropanol (isopropyl alcohol) Isopropyl acetate Isopropyl ether Isobutylaldehyde (technically pure) Iron (Ill) ammonium sulphate Iron salts J Jam Javel water (sodium hypochlorite) Jelly K Kaolin, washed/ground Kerosine (petroleum) Ketone Kitchen salt, saturated (sole) L Lactose Lanolin Lactic acid Latex (caotchouc dispersions) Lead (Il) acetate Lemon aroma Lemon juice Lemon zest Lime (calcium hydroxide) Lime water Linseed oil Lighting gas, benzole free Levoxin 15 (diamin hydrate) Liquid soap Liquor Lemonade Lipoids (lecithin, emulsifiers) Lithium bromide Lixtone SO Lixtone TS 803/M Lubricant oils Lubricant soap Lysoform (disinfectant; acqueous solution var. higher aldehydes) Lysol

32 any VL 12 any

q q q q

q q q q q q q q

5 G

TR TR 100 TR 100 GL any

q q q q q q q q

q q q q q q q q


q q


q q q q


q q q

H 5

q q q

q q q q q q

any TR 100

q q q

q q q q q

TR any any

GL TR H TR H any

q q q q q q q q q q q q q q

q q q q q

q q q q q

q q q q q q q q

q q q q q q q q q q q q q q q q q q q q

VL

M Magnesium carbonate Magnesium chloride Magnesium fluorsilicate Magnesium hydroxide Magnesium iodide Magnesium salts Magnesium sulphate Maleic acid Malic acid Malic acid Malic acid Manganese sulphate Margarine Maschine oil Mashed potato Mashes Mayonnaise Molasses Molasses aroma Menthol Mercuric chloride Mercuric salts Mercury Mersol D (mixture of higher paraffin sulfonic acid chlorides) Metallic mordant Metallic soap Methacrylic acid Methane, gaseous Methanol (methyl alcohol) Methoxybutanol Methoxybutyl acetate (butoxyl) Methyl alcohol (methanol) Methyl acetate Methyl acrylate Methylamine Methylbenzene (toluol) Methyl bromide, gaseous Methyl chloride Methylcyclohexane Methylene chloride Methyl ethyl ketone Methyl glycol Methyl isobutylketone Methyl metacrylate 4-Methyl-2-pentanol Methyl propylketon n-Methyl pyrrolidone Methylsalicylate (Salicylic acid methyl ester) Methyl sulphuric acid Methyl sulphuric acid Metol (4-methyl-amino-phenosulphate) (photographic-developer) Milk Mineral oil, without additives Mineral oil, free of aromatic compounds Mineral water Mixed acid I (sulphuric acid/nitric acid/water) 48/49/ 3 50/50/ 0 10/87/ 3

GL any GL any any GL 1 50 GL

q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q

q q q q q q q q q q

q q q q q q q q q q

10

q q q q

TR


q q q q q q q q q q q q
11

H TR TR GL TR 100


q q q

q q q q q q q

12

TR any TR any TR 32 TR TR TR TR TR


q q q q q
13

q
q q q q q q q q q q q q


q q

14


q q

50 100 VL H H H

q q q q q

q q


q q q
15

16

72

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 73

Chemical resistance list


9 2

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C

50/31/19 50/33/17 10/20/70 Mixed acid ll (sulphuric acid/phosphoric acid/water) 30/60/10 Monochlorbenzene Monochloracetic acid ethyl ester Monochloracetic acid methyl ester Monoethylamine Morpholine Motor oil Mowilith-dispersions N Nail varnish Nail varnish remover Naphtha Naphthalin Natural gas Nekal BX (interlacing agent; sodium salts var. isopropyl naphthaline sulphonic acids) Nickel chloride Nickel nitrate Nickel salts Nickel sulphate Nicotine Nicotinic acid Nitric acid Nitric acid Nitric acid Nitric acid Nitric acid Nitric acid Nitrochloroform Nitrobenzene Nitrocellulose Nitrogen (gaseous) Nitrous gases Nitrotoluols Nolan stop-off lacquer (dangerous substance) Nolan thinner (dangerous substance) Nonyl alcohol (nonanol) Nut oil O Octyl cresol Oleic acid Oil of cloves Oils, distilled Oils, mineral, without additives Oils, mineral, free of aromatic compounds Oils, vegetable and mineral Oleum, 10% SO3 Oleum vapours (sulphur trioxid) Oleum vapours Oleic acid O-nitrotuluol Optical whiteners Orange juice Orange zest Orotol Oxalic acid


q q q q q q

Oxygen Ozone, gaseous 50 pphm Ozone, gaseous 2% Ozone

TR

GL


100 100 any TR q q q q q q


q q

H TR H any GL GL GL any VL 6,3 25 40 50 65 75 TR any 5 TR

q q q q q q q q q q q q q q q q q q q q q q q

q q q q q q

q q q q q q q q q q q q q q q q q q q q q q

TR


q q

H H 5 TR TR TR

q q q q
q q q q q q q q q q q


q q

GL

q q q q

P P 3 Galvaclean 20 (dangerous substance) P 3 Galvaclean 42 = P 3 S (dangerous substance) P 3 Galvaclean 44 (dangerous substance) P 3 Galvaclean 45 (dangerous substance) P 3 Galvaclean 65 (dangerous substance) P 3 Manuvo hand cleaner (dangerous substance) P 3 Saxim (dangerous substance) P 3 Standard (dangerous substance) P 3 7221 (dangerous substance) Palmityl acid Palmityl alcohol Palm kernel oil Palm oil H Palm kernel oil acid TR Paraffin 100 Paraffin emulsion H Paraffin oil TR Paraformaldehyde Parfume Paris inert oxyd (dangerous substance) Peanut oil Pectin GL Pentanol TR Peppermint oil TR Perchlorethylene TR Perchloric acid 20 Perchloric acid 50 Perchloric acid 70 Perhydrol (hydrogen peroxide, acqueous solution) 40 Petroleum ether TR Petroleum (kerosene) TR Petroleum spirit (light petrol, free from aromatic compounds) 100 Petrol, regular grade H Photographic emulsion H Photographic developer H Photographic fixer bath H Pineapple juice Pine needle oil Phenol (carbolic acid) any Phenol resin mould substances Phenylamine (aniline) GL Phenylethyl alcohol Phenylhydrazine TR Phenylhydrazine hydrochloride Phenyl sulphonat (Sodium dodecylbenzene sulphonate) Phosgene, gaseous TR Phosgene, liquid TR Phosphates any Phosphoroxichloride Phosphorpentoxide 100 Phosphoric acid 50 Phosphoric acid 95 Phosphortrichloride TR Phosphoryl chloride TR

q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q

q q q q q q q q q q q q q

q q q

q q q q q q q q q q q q


q q


q q

q
q q q q q q


q q q

q
q q q q q q q q


q q q q q q q q


q q q q q q

73
1

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 74

Chemical resistance list


8

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C

Phtalic acid Phtalic acid Phtalic acid ester Picric acid Picric acid Polychlorinated biphenyl (PCB) Polyester resins Polyester softeners Polyglycols Pork dripping Potash (potassium carbonate) Potassium ferrocyanide, pot. ferricyanide Potassium ferricyanide and potassium ferrocyanide Potassium cyanide Potassium ammonium sulphate (alum) Potassium carbonate Potassium bichromate (potassium dichromate) Potassium bisulphate Potassium borate Potassium borate Potassium bromate Potassium bromate Potassium bromide Potassium cadmium cyanide Potassium carbonate (potash) Potassium chlorate Potassium chloride Potassium chromate Potassium chromate Potassium cyanide Potassium dichromate (potassium bichromate) Potassium ferricyanide Potassium fluoride Potassium hexacyano ferrate Potassium hydroxide (caustic potash) Potassium iodide Potassium nitrate Potassium perborate Potassium perchlorate Potassium permanganate Potassium permanganate Potassium persulphate Potassium phosphate Potassium sulphate Potassium sulphite Potassium sulphite Potassium tetracyanocuprate Potassium thiosulphate Propane, liquid Propane, gaseous i-Propanol n-Propanol (n-propyl alcohol) Propargyl alcohol Propionic acid Propionic acid Propylene chloride Propylene glycol Propylene oxide Prussic acid

50 GL 1 GL

q q q q q q

q q q q

Prussic acid (hydrocyanic acid) Pseudocumol Pyridine Q Quinine R Ratak Resit 65 (Fuchs) Rectified spirit (ethanol, ethyl alcohol, spirit of wine) Rinsing agents Roaster gases, dry Rum

10 TR

q q


q q


q q


q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q


q q q q q q q q q q q q

q 96 H any 40 q q q q q q q q q q q q
10

any any any any any any any any 10 GL VL GL any any any any any 40 GL any any any any any 50 any any GL 20 GL any any any L


q q q q q q q q q q q q q q q q


q q q q q q q q q q q q

TR TR TR TR 7 50 TR 100 TR TR TR


q q q q q q

S Saccharic acid GL Sagrotan (disinfection, chlorophenol soap solution) VL Sagrotan Salicylic acid GL Salicylic acid methyl ester (methylsalicylate) Sal-ammoniac (ammonium chloride) any Salt (sodium chloride) any Saturated steam concentrate Seawater H Separating agent Sewage Shampoo Shoe cream Silicic acid any Silicofluoric acid 40 Silver nitrate any Silver salts GL Silicon oil TR Soda (sodium carbonate) any Soap solution any Soda Iye (sodium hydroxide, caustic soda) any Soda water (carbon dioxide) any Sodium acetate any Sodium aluminium sulphate Sodium benzoate GL Sodium benzoate 36 Sodium bicarbonate (sodium hydrogen carbonate) GL Sodium bisulphate (sodium hydrogen sulphate) GL Sodium bisulphitt (sodium hydrogen sulphite, sodium disulphite) any Sodium borate Sodium bromate L Sodium bromide L Sodium carbonate (soda) any Sodium chlorate any Sodium chloride (salt) any Sodium chlorite VL Sodium chlorite 20 Sodium chlorite bleaches H Sodium chromate VL Sodium cyanide GL Sodium dichromate GL Sodium disulphite (sodium bisulphite) any Sodium dithionite VL Sodium dodecyl benzene sulphonate (phenyl sulphonate) Sodium ferricyanide

q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q

q q


11

q q


q q q q q q q q q q q q q q q q q q q q q q q q q q q q q


q q q q q q q q q q q q q q q

12 13

q q q q


q q q q q q q q

14


q q q q q q q q
15


q q q q q q q

q q q q

16

74

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 75

Chemical resistance list


9 2

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C Flow through substance

Geberit HDPE
Proport. Performance at % 20 40 60C

Sodium fluoride Sodium hexacyanoferrate Sodium hydrogen carbonate (sodium bicarbonate) Sodium hydrogen sulphate (sodium bisulphate) Sodium hydrogen sulphite (sodium bisulphite) Sodium hydroxide (caustic soda) Sodium hypochlorite (Javel water) Sodium hypochlorite Sodium iodide Sodium copper cyanide Sodium nitrate Sodium nitrite Sodium oxalate Sodium perborate Sodium perchlorate Sodium peroxide Sodium peroxide Sodium peroxodisulphate (sodium persulphate) Sodium phosphate Sodium silicate (water glass) Sodium sulphate (Glaubers salt) Sodium sulphide Sodium sulphite Sodium thiosulphate (fixative salt) Softeners Soya oil Spermaceti Sperm oil alcohol (mixture of higher oil alcohols) Spindle oil Spin bath acid, containing CS2 Spirits Stain remover Stannous (Il) chloride Starch Starch syrup Stearic acid Stellhefen flavouring (aqueous solution of maltose and dextrines) Styrol Succinic acid Suet Sugar beet juice Sugar solutions Sugar syrup Sulphate Sulphur Sulphur dichloride Sulphur dioxide Sulphur dioxide, gaseous, dry and damp Sulphur dioxide, liquid Sulphurated potash (potassium polysulphide) Sulphuric acid Sulphuric acid Sulphuric acid Sulphur sodium (sodium sulphide) Sulphur trioxide (oleum vapours) Sulphur trioxide Sulphurous acid

GL GL GL 10 any any 5 12,5 L any any any GL any 10 GL GL GL any any any GL any

q q q q q q q q q q q q q q q q

q q q q q q q q q q q q q q q q q q q


q q q q q q q q q q q q q q q q q q


q q q q q q q q q q q


q q


q q q q q q q q q

100 TR 0,01 H any any any TR L any TR any any H any TR TR any any TR any 10 70 90 any 5 TR GL


q q q q q q

q q q q q q q q q q q q q q q q q q q q q q q q q q q q q

T Taningan extra (synthetic tanning substances) Tannic acid (tannine) Tannin (tannic acid) Tea Tar Tartaric acid Turpentine Tetrabromethane Tetrachloroethane Tetrachloroethylene Tetraethyl lead Tetrahydrofurane Tetrahydronaphthalin (Tetralin) Thioglycol (thiodiethylene glycol) Thioglycolic acid Thiocarmabide Thionyl chloride Thiophene Tincture of iodine DAB6 Tiutol (hypochlorite Javel water) Toluol (methyl benzene) Tomato juice Transformer oil Triethanolamine Triethylene glycol Tributyl phosphate Trichloroethane, gaseous Trichloroethane Trichloroethylene Trichlorobenzene Trichlorethylphosphate Trichloroacetic acid Trichloroacetic acid Trichlorofluorethane (freon 11, Sdp. 24C) Triethanolamine Tricresylphosphate Trilon Trimethylborate Trimethylolpropane Trisodium phosphate Trioctylphospate T-SS up to 5% Two-stroke oil Typewriter oil U Universal thinners Uric acid Urine V Vaseline oil Vinegar (wine vinegar) Vinyl acetate Viscose spinning solutions Vitamin C (ascorbic acid)

GL 10 10 G any TR TR TR TR TR TR 100

q q q q q q

q q q q

q q q


q q


q q q q q

q q q q any q TR TR H q q 12/13 TR q q q TR q TR q q q q q q TR q q q 100 TR TR q q q 50 q q q TR q 100 TR q q q TR q q q q q q q q q q q q q TR q q q q q q q


GL 33 q q q q q q


q q q


TR H TR

q q q q q q q q


q q q q q q q q q q q q


q q q

75
1

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 76

Chemical resistance list


8

Geberit HDPE
Flow through substance Proport. Performance at % 20 40 60C
9

W Wax alcohols TR Waxes Walnut oil Washing agents G Washing up liquid Water, distillied Water, fully desalinized Water de-ionized Water chlorinated driking water Water, ozonized drinking water Water glass (sodium silicate) any Wattle, vegetable H Wattle, from cellulose H Wine H Wine vinegear (vinegear) H Wine spirit (ethyl alcohol, ethanol, rectified spirit) 96 White spirit TR White spirit (cristal oil) TR Whisky H Whwy Wood stain G X Xylene (isomer mixture) Y Yeast Z Zampon thinners Zinc carbonate Zinc chloride Zinc oxide Zinc salts Zinc sludge Zinc dust Zinc stearate Zinc sulphat

q q q q q q q q q q q q q q q q q q q


q q q q q q q q q q q q

10

q q q q q q q q q q
11


q q

TR

any

q q
12


GL any GL any any any q q q q q q q q q q q q q q q q q q q q q q q q

13 14 15 16

76

Geberit HDPE Installati 1.12.03


1

1/12/03

2:51 pm

Page 77

Certificates
9 1 8 2

British Board of Agrment Geberit HDPE pipes and fittings have been certified by many European authorities and in 1976 also received BBA certification. The British Board of Agrment, in consultation with the secretary of state, reissued the BBA Certificate 92/2796 in 1992. Geberit pipes, adapters and fittings also comply with ISO R 161/1 recommendations.

European Quality Certificate ISO 9001.2000 For its manufacturing plants in Europe, Geberit has received the highest quality system certification available, issued by the Swiss EQ-Net member SQS for compliance with the ISO 9000/EN 29000 series, which corresponds to BS 5750. EQ-Net members are in all countries throughout Europe, including BSI QA United Kingdom.

Institute of Plumbing Geberit is an industrial associate member of the Institute of Plumbing.

ISO 14001
WPC/World Plumbing Council Geberit is an active member of the renowned World Plumbing Conference.

KOMO certificate for quality of construction materials.

DIN
2

Standards Geberit HDPE conforms to:

DIN 19535 Pipes and fittings of high-density PE for hot water resistant waste and soil installations within buildings. DIN 19537 Pipes and fittings of high-density PE for drainage and sewerage. DIN 8074 High density polyethylene (HDPE) pipes; dimensions. DIN 8075 High density polyethylene (HDPE) pipes; general quality requirements and testing.

Geberit HDPE Installati 1.12.03

1/12/03

2:51 pm

Page 78

Ref GT15-1003

Other HDPE literature also available from Geberit Ltd. ! Product and price guide ! Drainage System Other innovative products available within the Geberit Ltd. product portfolio include: ! Geberit Duofix wall hung sanitaryware installation systems, WC and urinal flushing systems, electronic washroom solutions and shower toilets ! Geberit Mepla water supply ! Geberit Syphonics Roof Drainage ! Geberit Terrain Rainwater Systems ! Geberit Terrain UPVC soil, waste and underground drainage systems ! Geberit Terrain Special Fabrication Service Please call 0700 4323748 or visit www.geberit.co.uk for more information.

Geberit Ltd. New Hythe Business Park New Hythe Lane Aylesford, Kent ME207PJ

Tel:+44 (0)1622 717811 Fax:+44 (0)1622 716920 www.geberit.co.uk

Registered office as postal address Registration Number 761885

A D V A N C E D

P L U M B I N G

T E C H N O L O G Y

Вам также может понравиться