F2 Q1 K1/K2 F3
- Overload relay - MPCB / ACB / MCCB - Main isolating contactors (AC-3 rated) - Semiconductor Fuses (Optional)
BH BF ME MH
- Command "Ramp-up" - Command "Enable" - Monitoring signal "In operation" - Monitoring signal "End of ramp"
Note :
*
**
Fan supply 230 V AC external power supply *** Thermistor or thermostat motor protection
5.1
SIKOSTART
Basic connections for PLC with 24 V = industry logic Q1- MPCB / ACB / MCCB K1 - Main isolating contactor (AC-3 rated) F3 - Semiconductor Fuses (Optional) F2 - Overload relay L - is preferably to be earthed. Remove link 49-50 if there is a potential difference between L - and PE (max. permissible voltage 60 V)
Note : * ** With I-Option card only (C. T. connection) Fan supply 230 VAC external power supply *** Thermistor or thermostat motor protection
5.2
SIKOSTART
Recommended connection : SIKOSTART 3RW24 Line Connection for Soft Start (also with I-OPTION card)
G1 F1 K1 F3 K3 S1 S2 F2
= = = = = = = =
SIKOSTART Motor feeder HRC fuses Main isolating contactor (AC-3 rated) Semiconductor fuses (Optional) Bypass contactor (Optional) OFF push button (Momentary command) ON push button (Momentary command) Overload relay
Note : * ** With I-Option only (C. T. connection) Fan supply 230 VAC external power supply
5.3
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Delta Connection for Soft Start (also with I-Option card)
G1 = SIKOSTART F1 = Motor feeder HRC fuses K1 = Main isolating contactor (AC-3 rated) F3 = Semiconductor fuses (Optional) K3 = Bypass contactor (Optional) S1 = OFF push button (Momentary Command) S2 = ON push button (Momentary Command) F2 = Overload relay *MU - only with I-Option card
Note : * ** With I-Option only (C. T. connection) Fan supply 230 VAC external power supply
5.4
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Line Connection Soft Start and Soft Stop (also with I-Option card)
G1 F1 K1 F3 F2
= = = = =
SIKOSTART Motor feeder HRC fuses Main isolating contactor (AC-3 rated) Semiconductor fuses (Optional) Overload relay
K3 S1 S2 K2
= Bypass contactor (Optional) = OFF push button (Momentary Command) = ON push button (Momentary Command) = Auxiliary contactor (4 NO)
Note : * ** With I-Option only (C. T. connection) Fan supply 230 VAC external power supply
5.5
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Line connection as a Soft Start and Soft Stop for reversing application
G1 F1 F3 K1f
SIKOSTART Motor feeder HRC fuses Semiconductor fuses (Optional) Main isolating contactor in forward direction K1R = Main isolating contactor in reverse direction F2 = Overload relay ON1 = Forward direction
= = = =
Reverse direction Bypass contactor (Optional) Auxiliary contactor (4NO + 4NC) Auxiliary contactor (4NO + 4NC) OFF push button (Momentary Contact) S2.0 = ON push button S2.1 (Momentary Contact)
Note : * ** With I-Option only (C. T. connection) Fan supply 230 VAC, external power supply
5.6
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Line connection (also with I-Option) for soft start and speed change of motors in the pole-change Dahlander connection. This connection provides for zero-current contactor switching
= = = = = = = = = =
SIKOSTART Motor feeder HRC fuses Semiconductor fuses (Optional) Main isolating contactor (AC-3 rated) Bypass contactor (Optional) Auxiliary contactor (3NO + 1NC) Auxiliary contactor (4NO) Contactor - Slow speed Aux. Contactor (4NO) Aux. Contacor (4NO)
K22-1= Star contactor (Dahlander wdg. only) S2 = ON slow speed (Momentary Command) S3 = ON high speed (Momentary Command) S1 = Off command (Momentary Command) F2 = Overload relay F4 = Overload relay
Note : * ** With I-Option card only (C.T. Connection) Fan supply 230 VAC external power supply
5.7
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Line connection I-Option card combined with a star/delta starter for starting with low starting currents (e.g. screw compressors in bypass).
PE
L1
L2
L3
~ 110...415 V
21
F1
K6 MU
22
F2
S1 OFF S2 ON
F2
K6
F3
**
K1 k4 k4 K1 K2 K1 K2 k3 k4 k4 K1 k3
41 1 2 3 4 5 6 7 8 BF 9 SW 10 T1 T2 BH P10 42 ME MH PE L1 L2 L3 F
G1
SIKOSTART 3RW24
O PE 49 50
K1
K6
K3
K2
k4
K1 H
T3
K2
K3
W1 V1 U1
W2 V2 U2
G1 F1 F3 K1 F2 K2
= = = = = =
SIKOSTART Motor feeder HRC fuses Semiconductor fuses Bypass contactor Overload relay Delta contactor
K3 K4 S1 S2 K6
= Star contactor = ON -delay timers = OFF Push button (Momentary Command) = ON Push button (Momentary Command) = Line contactor
Note : * ** With I-Option card only (C.T. Connection) Fan supply 230 VAC external power supply
5.8
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Delta connection combined with a star/ delta starter for emergency starting)
G1 F1 F3 K1 K2 K3 F2
= = = = = = =
SIKOSTART Semiconductor fuses Motor feeder HRC fuses Bypass contactor Delta contactor Star contactor Overload relay
K5 K4 S1 S2 S3 K6
= Auxiliary contactor (3NO + 1NC) = 7PU60 star-delta timer = OFF push button (Momentary Command) = ON push button (Momentary Command) = Star-delta change over switch = Line contactor
Note : * ** With I-Option card only (C. T. connection) Fan supply 230 VAC external power supply Rapid push button start is not possible. Push button must be pressed for sufficient time.
5.9
SIKOSTART
Recommended connection : SIKOSTART 3RW24, Line connection as a voltage controller (e.g. for running the motor at lower speed, special motor, control of electric heating)
G1 = F1 = K1 = F3 = US -11 = F2 =
SIKOSTART Motor feeder fuses Main isolating contactor (AC-3 rated) Semiconductor fuses 10k potentiometer Overload relay
Note : * ** With I-Option card only Fan supply 230 VAC external power supply *** Thermistor or thermostat motor protection
5.10